Home

LT3 / LT7 Lämpökamera

image

Contents

1. NE 1 USB output Inserting USB cable to this port and connecting to computer for data transmission only support USB2 0 2 TF Card slot Accepting standard size TF card such as supplied 2GB capacity card for device upgrade or image storage 3 Video port It is a video output interface 4 Power interface External power input interface Power source should be 12VDC Center pin is positive terminal 3 Basic operation 3 1 Battery Installation and Replacement 3 1 1 Inserting or removing battery Battery compartment is located inside the handle Turn the cover counter clockwise to remove Remove battery for replacement Insert the battery the battery contacts must face into the battery compartment Replace the cover and screw down I CAUTION Use only original manufacturer replacement battery Use of incorrect battery may result in physical or electrical damage to the instrument due to incorrect voltage or physical size difference 3 1 2 Replacing battery When battery has approximately 5 charge remaining the warning will be displayed and the instrument will turn off in approximately 3 seconds Powering off display It s better to replace batteries now 3 2 Battery safety and usage gt Batteries should be stored in an ambient temperature of 4 F 20 C to 67 9 F 20 C Lithium batteries will self discharge during storage
2. L mp kamera 23 32 K SIKIRJA LT3 LT7 J rjestelm asetukset Paina Menu gt Stup gt Sys Setup ja paina Hyv ksy Voit valita kielen Automaattisen kalibroinnin LCD n yt n kirkkauden Liipaisimen toiminnon Video standardin Tyhj k yntiajan ja Automaattisen poiskytkent ajan Valits muutettava Yl s Alas painikkeilla ja muuta Vasen Oikea painikkeilla e Kielen valinta 11 kielt Englanti Espanja Ranska Saksa Italia ja Portugali Ven j Japani Yksinkertainen Kiina ja perinteinen Kiina e Auto Calibration Voit valita pitk n lyhyen tai yksil idyn Yksil idyss tavassa voit valita O ei kalibrointia ja arvot 30 600 1 sekunnin v lein Automaattisella kalibroinnilla parannetaan kuvan laatua ja mittaustarkkuutta j yt n aikana e LCD Brightness K ytt j voi valita kirkkauden 20 40 60 80 ja 100 e Trigger K ytt j voi m ritt liipaisinpainkkeen toiminnon o Laser Liipaisin kytkee Laser t t imen p lle Pois o Spot Temp Lis tai poistaa piste mittauksen o Area Temp Lis tai poistaa aluemittauksen 23 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 I voidan www pictiko fi info pictiko fi Lampokamera 24 32 KASIKIRJA LT3 LT7 o Save Key kaynnistaa tallennuksen o IR CCD vaihtaa IR tai CCD kuvan e Video Mode Voit valita PAL tai NTSC videostandardin e Standby Time Voit valita None 2 5 10 tai 15 minuuttia Jos mitaan painiketta ei pai
3. e File Edit view Draw Window Help 2 2 1 File menu D ew Ctrl N en Ctrl 0 lose In 19 le fe Save Ctrl 5 Save As Export To Word amp Print Ctrl P E Print Preview Print Setup 1 Demo rpm Batch Exit Dali infrared analysis report software DL Reporter User manual 2 2 2 Edit menu Zoom lt sI lt I lt sl lt T lt s 2 2 4 Drawing menu Dali infrared analysis report software DL Reporter User manual 2 2 5 Windows menu Tile Arrange Icons igo 2 2 6 Help menu About 2 3 Toolbar 2 3 1 Common Toolbar DEO SRC 2 3 2 Drawing toolbar ARG OMSO BMG o s A 2 3 4 Analysis toolbar m OO xASE zies 2 3 5 Page toolbar 4 4 gt DI Page 1 report1 x Q Q A X 10 Dali infrared analysis report software DL Reporter User manual 2 3 6 Objects toolbar 11 Dali infrared analysis report software DL Reporter User manual 3 Start to use 3 1 Create new report After start the software a new report has been setup by default If another report needs to be created it can be created by directly press the D button in the toolbar and also by select the file gt new in the submenu Template Page x Em Page Fig o In this dialog space user can choose to create a plain report or use the prior made template to create a report 3 2 Open up saved reports
4. Digitaalinen zoom X2 kun aktivoitu Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pietiko fi info pictiko fi Lampokamera 16 32 KASIKIRJA LT3 LT7 Paavalikko 1 Paavalikossa nakyy nelja vaihtoehtoa Mittaus taso alue asetukset tiedosto 2 Alavalikko gt ilmoittaa etta alavalikko on olemassa t lle parametrille Alavalikkoon menn n oikealla nuolin pp imell Dialogikehys 1 Kehyksen nimi esim Measuring Setup i N 2 Parametrin nimi 3 Parametrin sis lt Mustalla tekstill voimas sa oleva valkoisella parametri joka ei ole k y t ss t ss yhteydess 4 Yksikk Kehotekehys 1 kehotteen nimi 2 Kehotteen kysymys f Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pictiko fi info pictiko fi 7 Mittausongelimasi ratkaisua Lampokamera 17 32 KASIKIRJA LT3 LT7 Mittaus Tata valikkoa kaytetaan mittausarvon lis miseen tai poistamiseen Paina Valikko Hyv ksy painiketta ja valitse Measurement ja hyv ksy jolloin mittauksen dialogikehys tulee n kyviin Vasen ja oikea painikkeilla askeltaa mittausvaihtoehdot Jos haluat muuttaa valittua parametria paina Hyv ksy painiketta Vaihtoehtoja ovat e None ei mit n kaikki mittaukset poistuvat n yt lt e Add Hot Spot lis liikkuvan kursorin joka automaattisesti n ytt kuumimman kohdan kuvassa SH ja H e Add Cold Spot lis liikkuvan kursorin kuvan kylmi
5. If the amendments or verifications need to be done on saved reports please press icon on toolbar or by select file menu file open in submenu the standard Windows file dialog box will popup By change the file path or others to choose the file reguired and then press the open button to open The extension of the report file is rpt when the file has been opened a new sub window will be opened up automatically The window looks as below Dali infrared analysis report software DL Reporter User manual Ee x Look in 3 Dali Infrared Reporter lt c E3 File name InfraRpt Files of type DI Report rpt 1pm v Cancel h Fig oo 3 3 Save report After the new amendments or verifications when report need to be saved the button on the toolbar can be pressed or to select the file gt save in submenu the standard file saving dialog box will popup By changing the file path or so to choose the needed saving path and input the file name press the save button to save The extension of the report file is rpt Save in Sy Dali Infrared Reporter ec Ee template Save as type DI Report rpt rpm Cancel Fig oo 3 4 Save as report If the flies have to be saved without over writing the saved report the save as can be used By select file save as in submenu the standard save as dialog box will popup 13 Dali infrared anal
6. of potential spark ignition sources Medical Human body surface temperature detection and screening o Petro chemical Oil pipeline status inspection material surface temperature detection insulation inspection power equipment status etc 1 1Standard accessories Infrared thermal image camera with wrist strap Carrying case Video out cable Lithium ion batteries 2 User manual Infrared report and analysis software system CD Lithium battery charger Lens cap User manual Infrared report and analysis software system CD TF card TF card reader USB cable 1 2 Optional accessories External 0 5x wide angle lens External 2x telescopic lens Eye patch Power adapter with power cable and plug 2 Camera overview 2 1 Function keys 1 Power key Press and hold the Power Key for gt 3 seconds to power on off the camera Note After powering off please wait ten seconds before powering the camera on again 2 Select Auto key Marked A The A or attribute button performs 2 functions a The first function is modification of selected parameters It is obtained by a quick press and release less than 2 seconds with this functions to modify their parameters Subsequent presses will scroll through the available parameters The selected function will be hig
7. varten Voit my s tallentaa kuvan e Jos kohteen l mp tila on alempi tai korkeampi kuin kameran rajat n yt ll n kyy lt xxx tai gt xxx xxx on valitun mittausalueen raja arvo e Mittausasetusten muuttaminen tapahtuu valitsemalla haluttu parametri ja sen j lkeen painamalla Hyv ksy painiketta N yt lle tulee asetusten valintakysely Pisteen asetuksissa voit valita emissiviteetin ja vertailul mp tilan Jos asetetaan piste vertailul mp tilaksi muut l mp tila arvot n yt ll ovat erotuksia t st referensiil mp tilasta Viivan asetuksissa voit m ritt vain emissiokertoimen Alan asetuksia ovat edellisten lis ksi mittaustyypin min max tai keskiarvol mp tila Area Move pane tai koko Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 I voidan www pictiko fi info pictiko fi L mp kamera 14 32 KASIKIRJA LT3 LT7 Pys yt ja tallenna kuva Paina S painiketta ja kuva pys htyy paina C ja palaat normaalin ytt n Kuvan voi tallentaa kolmella tavalla e Paina S ja valitse Save tai valitse Cancel ja palaat ilman tallennusta e Paina Menu ja valitse File gt gt Save ja j rjestelm k ynnist tallennuksen e Jos Liipaisin Trigger parametri Setup gt Sys Setup gt Trigger on asetettu SaveKey asentoon Liipasinta vet m ll tallennus k ynnistyy Tallennettujen kuvien katselu e Paina Menu ja aktivoi p valikko Valitse File gt Open e Kuntallennettu k
8. 1 Setup analysis The analysis can be done after import the infrared thermal image the analysis toolbar mainly include 1 Spots analysis additional spots after click on this button move the mouse to the corresponding thermal image and select the position need to be analysis mouse symbol as cross hair click on left mouse button to add on a new analytic spot there is no limit on analytic spot amount the system will title the spot in order JP010P020P03 Cand calculate and record the spot temperature automatically 2 1 Instantaneous spot analysis this button is similar with the spot analysis the main different is when you use this function and make the mouse move inside the infrared 23 Dali infrared analysis report software DL Reporter User manual thermal image area the instantaneous spot temperature will show on the point that mouse pointed to 3 SS Line analysis after activate this button move the mouse to the corresponding thermal image and select the starting position of the analytic line mouse symbol as cross hair hold on the left mouse button move the mouse and draw a line release the mouse button and a new analytic line will been created there is no amount limit on analytic line the system will title the line in order IL0170L02N0L003 7and calculate and record the highest lowest and average temperature on this line automatically 4 Rectangular analysis after activate thi
9. 4 3 7 Operations Of IR ObJeCt os sieste intrei s m a ke A eiet 21 Dali infrared analysis report software DL Reporter User manual 4 23 15 Greate IR ODJ6Chs ts secistteitei alta a T N Nm eas 21 4 3 2 LINK IR Object ccoooos a a aa ae ea aseensa 22 4 3 3 Analyze IR ODJECE eneee Tees STT Kes asa Nera e sms nE 23 4 3 3 1 Setupanalystsm mmesn nas neh Me eh ee A ee eels 23 4 3 3 2 Modify analysis issue a ean 25 4 3 3 3 Delete analyzesdusmsmnsmamusoumssimmmm sisemm ss 26 4 3 4 Infrared image parameters Setup ousussi e Lene 26 A 3 4 1 Image display Setup smasssana aan S AT A ISAS AI 27 4 3 4 2 Thermal images parameters Setup ouosusos e a n ne a na naene 27 4 3 4 3 Analysis parameters Setup uosuosssss m a e a a a na naa a Kaanaa eanet 28 4 3 4 4 Palette SetUPp s sssnsssssA nn bed lel BAS aah bade le SAS ahah EAS 29 43 52 VOICE playa CK 1 n sa em eh RUA een eB oh oes eorex 29 4 4 Use CCD image Object c ce cecceceseeseeseeseeeseeseeseeseeeseesecsecseeesesaecaeeeeeeaeeaeceeeeeeaeeaeeeeeeaees 29 4 5 Use formatted text object eceecceceesseseesseeseeseeseeeeeesessecseceeeeseesecaeceaeeaeeaeceeeaeeaeeaeenseeaees 30 4 5 1 Change font and align mode c oouosssssss n a ea neen 30 4 5 2 Copy paste text Contents ccoususm a a e aseen 31 4 5 3 Change font color frame and background ousussss eee 31 4 6 Use properties eiea a a a a aa aa aa a aa aa aa eaa aa e
10. CCD image for that saved image Press C key to exit the Image view mode and return to the real time measurement mode 3 3 5 Export saved images Use of USB port to download images in TF card With a standard USB cable connect device port to PC and export saved images Remove the TF card and insert into TF card reader connect to USB port on PC and export saved images 20 4 Operation guide 4 1 Graphic interface description 4 1 1 Screen graphic interface 1 Company logo DALI 2 Operating status displays the current operational status 3 Spot temperature measurement White crosshair 4 Selected spot temperature Yellow crosshair and show by 5 Emissivity Indicates Imagers emissivity setting 6 Minimum temperature Indicates minimum value of the palette 7 Palette Palette bar User can choose different palettes 8 Maximum temperature Indicates maximum value of the palette 9 Battery status Indicates the current battery status 10 11 Result Indicates the temperature value of the target object Black and yellow denotes the temperature value of the selected object 12 Temperature unit Three options C F or K 21 13 External lens symbol Displays 0 5x for wide angle or 2x for telephoto lens 14 SD card symbol Displays SD when TF card is installed 15 Digital zoom symbol Displays X2 when digital zoom is activated NOTE Not all models
11. Co Ltd does not guarantee the quality performance and applicability of this software if this PC software has been impliedly used in the circumstance other then Dali has been state out This manual will be updated for upgrade of versions and other purposes aperiodically Dali Technology reserve all rights of upgrade this manual without prior notice 1 3 Quality Assurance The quality manage system under which the products are developed and manufactured has been approved to be qualified for the ISO 9001 standard Dali infrared analysis report software DL Reporter User manual 1 4 Compatibility This version of software does not support the data created by previous versions of DaliPd infrared images analysis software The compatibility of Dali infrared cameras is as following 0O This software supports all DLI format data created by DL700BODL700CODL770A DL770BUiDL7010DL778 If better image quality is expected the version of camera s operation system should be version 46 or high To upgrade the system please contact the after sales department of Zhejiang Dali Technology Co Ltd 1 5 System reguirements The files which involved in the Dali Thermal Images Analysis Report Software are thermal images CCD pictures and graphics Those three kinds of files are far larger than the ordinary file therefore the PC system should have large enough memory capacity hard disc space and also the high processing capability and high scre
12. E Customer Information Please enter your information Please enter your name the name of the company for whom you work and the product serial number User Name yf2 Company Name dali Serial Number Jrassss InstallShield lt Back Cancel Fig O Please notel All those three items must be entered or the next button will not be Dali infrared analysis report software DL Reporter User manual active Please find the serial number on the cover of the installation CD Step threeQ Select the next the system shows that this process will install the Dali Thermal Images Analysis Report Software into the directory of WINDOW system InstallShield Wizard xi MAMMAN Choose Destination Location Select folder where Setup will install files Setup will install Dali Infrared Reporter in the following folder Toinstall to this folder click Next To install to a different folder click Browse and select another folder Destination Folder C Program Files DALI D ali Infrared Reporter Browse InstallShield Fig O Step four Allow you to check again the previous installation selections when next are chosen the system will start to copy files to your PC system InstallShield Wizard x Start Copying Files Review settings before copying files Koy Setup has enough information to start copying the program files If you want to review or c
13. System can create new page optionally for multi page operation Add page Click on Add page button a in main interface system will popup Add Page dialog box such as below By settings in the box user can make new page Add at last Add atfirst Before current After current add add at last Current page number m add at first Page Title before current i after current Fig 40 Delete page On plain space of the page click on mouse right button to popup submenu select 39 Dali infrared analysis report software DL Reporter User manual delete or click on button in control toolbar to delete current page Please note delete the page will also delete all contents in the page Move page System displays in single page if user wants to work on another page another page should be switch on It can be done through page management toolbar Iq First page 4 Previous page b Next page H Last page E zi Go to Zoom on out page Using the page management toolbar in main interface to zoom in or out the page and adjust the vision a Zoom in Q Zoom out R Full page Q 100 40 Dali infrared analysis report software DL Reporter User manual 5 Use USB For DL 700 serial products connect on USB tune on the camera system configuration will set storage medium as flash it can be use directly If setup as CF card please make sure the CF c
14. align 4 5 2 Copy paste text contents Formatted text object can use to paste the files from Clipboard and Microsoft Word copy the file from Word and click on mouse right button to popup text submenu select paste It also can copy the contents in the object blacked the needed text content and click on mouse right button to popup text submenu select copy 4 5 3 Change font color frame and background Blacked the text content that need change use A button in main interface toolbar to select the font color you want X button in main N Select the object if frame color need to be changed use interface toolbar if frame thickness need to be changed use button in main interface toolbar Select text object if text object background color need to be changed use 2 button in main interface toolbar select the background color needed The color selections show as below No Color BEEBE EE EE ENNEN oe E ETE E Em ATmpmE mE E gm BOUUUBETL More Colors Fig 30 4 6 Use properties The result table is used to show the infrared object parameters Click on result table 31 Dali infrared analysis report software DL Reporter User manual button in object toolbar and make it in active move the mouse to plain space on the page the mouse symbol become a cross hair press mouse left button and hold on the changing box which indicate
15. electromagnetic fields CAUTION Protect the surface of the lens from being stained or damaged by foreign objects such as sludge or chemicals Please replace the lens cap after use CAUTION Please remember to backup image data regularly to avoid losing important data NOTE For maximum measurement accuracy allow 3 to 5 minutes for camera to stabilize after initial power up NOTE Each camera is factory calibrated It is recommended that calibration be performed every 12 months CAUTION Do not open case Unit does not contain any user serviceable parts Repair should be performed by factory authorized technicians only Contents I Warnings Cautions and NOteS ssssssss5555 222550555555555uuu00u5555uunnnnnn 2 1 Introductio siiin ititicceevnccsctsccevwieddeWennentdeerscecndaccnuscvesedvaneurunetrneeee 6 1 1 Standardaccessones i024 r Beek sla aa E E a 8 1 2 Optional ACCESSOFIES 2 ee cess oe en e e eee e aseeseen 8 2 Camera OVETVIEeW uuuuuunuuau naan naan naa naan nana nananana nana aan aan annan an annan 9 2 12 FUNCTION KEY Si 1 eesti Raid earn ir ia eR ert 9 222 Interlac wssnoctieineank sean ate i ee 13 3 Basic operation scccscccecccenseesnseesceesneeesseeeeeeeaseesaseeaueesaeeesseeeeeeeasons 14 3 1 Battery Installation and Replacement ccc ccccescseeseessteeeeseeseeeenes 14 3 1 1 Inserting or removing battery oo nnen 14 3 12 Replacing batteri nalan tse Bice es SINESS
16. have all functions so the working status screen may not show all features 4 1 2 Main menu 1 Main menu Displays four options Measurement auto manually Setup and File 2 Low level menu The gt indicates a low level menu is available accessed by the right arrow key 4 1 3 Dialog box 22 1 Dialog box name Displays the dialog box name e g Measuring Setup 2 Item title A dialog box may contain several items such as Temp Range 3 Item content Items show specified content Black means valid or changeable and white means invalid for this selection 4 Unit Indicates the current selected temperature unit 4 1 4 Prompt box interface 1 Prompt box name Display the prompt box name e g Del file 2 Content Display the content in the prompt box e g Del Image File 4 2 Measurement Used for adding or deleting a measurement Press Menu key to activate the main menu Select Measurement and press Confirm key It will display the Measurement dialog box Use the Left and Right arrows to scroll through the available measurement options Highlight the option you wish to use and press Confirm key Options are e None Deletes all measurements from the screen e Add Hot Spot adds a moving cursor that automatically displays the hottest spot in the image Designated by SH and H 23 e Add Cold Spot adds a moving cursor that automatically displays the coldest spot in the image Designated by
17. mouse the effect will show on the image instantly 25 Dali infrared analysis report software DL Reporter User manual 2 Mouse in the top of the palette hold on left mouse button and draw whole section will move along with the mouse the palette will change the upper position 3 Mouse in the bottom of the palette hold on left mouse button and draw whole section will move along with the mouse the palette will change the lower position 4 3 3 3 Delete analyze To delete the corresponding infrared object analysis the x button in analysis toolbar must be in active the infrared object is in active as well use mouse to move around the infrared image When the mouse symbol change into sharp this analysis can then be deleted click on left mouse button to delete After delete operation system will update the analyze result and linear analysis object automatically Delete isotherm analysis click x button in analysis toolbar move mouse to the isotherm area of palette click on cursor to make symbol becomeliiiill click on left mouse button to delete Clear all analyses move mouse to corresponding infrared image click on mouse right button to popup infrared image analysis submenu select the remove analysis this will clear all the analyses one off does not delete isotherm analysis after this operation system will update the analyze result and linear analysis object automatically 4 3 4 Infrared image param
18. mp tilan Kaikki pisteet joiden l m tila ont t l mp tilaa korkeampi n ytt v t h lytykselle annettua v ri Jos v ri on asetet None tilaan vain h lytys ni kuuluu Jos h lytyst k ytet n alue mittauksessa valittu mittaustapa Min Max tai keskiarvo on my s kriteeri h lytyksen laukaisulle e Temp Alarm Off est h lytystoiminnon ON sallii ja mahdollistaa Set AlarmTemp ja Alam Color valinnan e Alarming Temp Asettaa h lytysrajan e Alarming Color Valitsee h lytt vien pixeleiden v rin e Isotherm Color Aktivoi isotermin saman l mp tilan alueen n ytt en kuvassa asetetun l mp tila alueen m ritetyll v rill e Isotherm Temp Asettaa isotermin keskil mp tilan e Isotherm Width Asettaa isotermin l mp tila alueen leveyden C 21 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Mitasnongelainel rakaistja www pictiko fi info pictiko fi L mp kamera 22 32 KASIKIRJA LT3 LT7 P iv m r ja aika asetukset Ajan ja p iv m r n asetus reaaliaikakelloa varten Valitse Menu gt Setup gt Date Time ja paina Hyv ksy painiketta Valitse muutettava yl s alas painikkeilla ja muuta Vasen Yl s painikkeilla Jos kamere on pitk n k ytt m tt voi reaaliaikakello pys hty kun sis inen paristo on tyhjentynyt 22 Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pictiko fi info pictiko fi Pietiko Oy Mittausongelmasi ratkaisua
19. on needed object eight sizing handles small black rectangular will appear in the frame the object has now been in active Please note Use mouse to click on the frame to select text object Move object All object can be move around the page optionally after select the object hold on mouse left button move the mouse system will show a rectangular to indicate the current position release mouse to confirm Change object size After select the object use mouse to activate the sizing handel hold on mouse right button move the mouse system will show a rectangular to indicate the current size release mouse to confirm Copy Copy is use for copy the object content into clipboard in form of picture or text After selected the object click on mouse right hand button a submenu will popup select copy to copy It also can carry out by select edit copy in main interface 38 Dali infrared analysis report software DL Reporter User manual Cut paste Cut paste is used as following after select the object click on mouse right button popup the submenu select cut or paste to work out It also can carry out by select edit cut or paste in main interface Delete Used to delete object directly click on mouse right button to popup the submenu select delete to delete It also can carry out by select edit delete in main interface 4 11 Page operations
20. so they should be fully charged before storage Self discharge may affect long term battery performance Furthermore it is recommended that the battery should be charged in a set time as below Ambient temperature of o 4 F 20 C to 67 9 F 20 C once every 6 months o 67 9 F 20 C to 113 F 45 C once every 3 months e 113 F 45 C to 149 F 60 C once every month Battery should have greater than 50 charge prior to recharge The ambient temperature for charging should be 32 F 0 C to 104 F 40 C If under 32 F 0 C the battery capacity will be diminished if over 104 F 40 C the battery may overheat resulting in permanent damage WARNING Never disassemble incinerate or puncture battery Never short circuit the battery Keep battery dry Keep out of reach of children Always dispose of battery in accordance with local state and federal regulations 3 3 Quick access 3 3 1 Capture an image oe After installing the battery press and hold the power key 23 seconds until the display comes on After approximately 50 seconds the power on routine will finish and the camera will start its measurements Remove the lens cap and aim at the target Adjust the focus for the clearest target thermal image NOTE Failure to properly focus the camera will result in increased measurement error 3 3 2 Temperature measurement If no measurement cursors are on screen add a measurement spot ar
21. the submenu select open also achievable by double click on left mouse button system popup the standard Windows picture dialog box select the picture file needed and confirm the CCD picture will show on the page such as below Fig oo Additional CCD picture can be created by click right mouse button on infrared object to popup submenu select show CCD If there is no CCD picture linked with this infrared image the item in the submenu will not be active 4 5 Use formatted text object Formatted text object is a powerful text edition function it support multi formatted text in same object also support change text font align mode and so on By this it is very easy to create an aesthetic text report Click on text tool in object toolbar to make it in active move the mouse to plain space on the page the mouse symbol become a cross hair press mouse left button and hold on the changing box which will appear release the button a new text object has been created There is no amount limit for text object the quantity only limited by the system memory capacity You can then work on the object to input or edit the text 4 5 1 Change font and align mode Times New Roman 12 v B 7 Fig 29 30 Dali infrared analysis report software DL Reporter User manual Blacked the needed text content use the drop down interface in main interface to select the text font size bold italic underline and
22. 0 Turku 02 2514402 Niamongolansi rakmistja www pictiko fi info pictiko fi Lampokamera 31 32 K SIKIRJA LT3 LT7 Muistikortin formatointi Paina Menu gt File gt Format ja Hyv ksy Paina Hyv ksy jos formatoit tai C jos et halua formatoida Varmista ennen formatointie ettei mit ntiedostoa tarvita 31 Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pictiko fi info pictiko fi Mittausongolmasi ratkaisua Lampokamera 32 32 KASIKIRJA LT3 LT7 5 Tekniset tiedot Detector characteristics Spatial resolution 1FOV 2 73mrad 1 37mrad 0 08 30T lt 0 06 030T Image Frame frequency S0 e0Hz SSS characteristics Pous O Mana o Spectrairange 8 i4um_ Built in CCD camera 1 3 million pixels COMS camera modules LCD displa 2 7 TFT LCD 320 x 240 200 3500 20T 6000 ee is greater Measurement E Up to 4 movable spots Up to 3 movable areas maximum minimum and average temperatures Up to 2 movable lines Line profile Isotherms Temperature difference Alarm voice Measurement Image control Image adjustment Auto manual gain and brightness a Date time temperature unit Background temperature correction Atmospheric Automatic correction according to user transmission input object distance humidity and correction temperature 2G SD card max 16G Manual Auto single file saving IR and Visual image link savina Thermal
23. 4 3 12 8 6 8 Line02 43 9 28 4 41 4 Fig 38 In the linear analytic result move the green instant temperature line the instant temperature will change accordingly the position of the point will also changed 4 9 Use histogram analytic tool The histogram tool is applies to analyze the histogram of beeline and measurement area it indicate the distributing of analytic beeline and measurement area more visually Method to use 1 Create object Click on profile tool button in object toolbar and make it in active move the mouse to plain space on the page the mouse symbol become a cross hair press mouse left button and hold on the changing box which indicate the position and size of the object will appear release the button a new histogram analysis object will be created 2 Create link The default linking object in histogram is the first line in first infrared object Double click mouse inside the histogram a dialog box for histogram linking selection will popup User can change the infrared object number choose the line number and display color of histogram 0 5 10 15 20 25 30 35 40 45 50 55 Line01 Histogram 37 Dali infrared analysis report software DL Reporter User manual IT x Histogram Connect IR image number il e Area number 1 Line number 1 Colour MN Fig 39 4 10 General operations of object Select object Click on N in toolbar make it in active click
24. 8 detektoria jonka mittausalue on 20 600 Toiminnot molemmissa malleissa L mp tila alueen manuaalinen tai automaattinen valinta Mittausyksik n valinta C K tai F 11 erilaista varipalettia 11 valittavissa olevaa kielta Kuumimman ja kylmimm n l mp tilapisteen mittaus 4 liikuteltavaa l mp tilapistett Aseteltava l mp tilan yl rajah lytys T Reflect Heijastuvan l mp tilan kompensointi 2 x digitaalinen zoom Kuvan pys ytys Videol ht PAL tai NTSC 3 alueen mittaus 2 linjan mittaus Kuvan tallennus TF kortille 5 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Tee a e e www pietiko fi info pictiko fi L mp kamera 6 32 K SIKIRJA LT3 LT7 N kyv n valon kamera ja tallennus niviestin tallennus kuvakohtaisesti Isotermin h lytys T Correct Mittauksen siirtym n korjaus Sis nrakennettu emissiokerrointaulukko Optiot LT3 ja LT7 malleihin voi tehdasasennuksena asentaa tele tai laajakulmalinssit Sovellukset Ennakoiva huolto e S hk laitteet S hk linjat ja s hk kaapit ongelma ja vikadiagnoosit e S hk laitteet Ylikuormituksen identifiointi e Mekaaniset laitteet Lis k ytett vyytt ja est suuremmat vikaantumiset Rakennukset e Katot vuotokohtien nopea paikallistaminen e Energiakatselmukset e Kosteusvaurioiden etsint Muut e Ter steollisuus Tutki prosesseja selvit kuumailmauunien vikoja 6 Pietiko Oy Tykist katu 4 B 310 P
25. I Factory Defaults 6st sos a E akin RAN I ARREN dasta 32 AS Fleer a a aAA he ae 33 a eo BET 1 o1 o E NME ATT TT 33 a STEPA Y h EO AEE E A E E E EE 34 4 5 3 Save Setting couuossos so eaa eaa ae eaa eaa ea aan ae a aanaesn 36 A54 AUTO Sa VE nire nea ney aes es to ents wn neediness 37 Aaa Delete urio E yva T din cua E A E E V A A 38 456 FOMA nonse n ke EA E T ATA a PASI TE ni 38 5 Technical specifications s sssssssssssss5555555uuu2uuuuuuuunnuuuunnnnnnnnnnnnnnn 40 Troubleshooting s sssssssssssssuuuuunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nn 42 Appendix A sssssss 5 55555555555uuu uuuu0uunnunuunnnnnnnnnnnnn nn 43 Common material emissivity FYI occ see eee 43 Appendix B ou ccsccceeeneeneeeceeneeeeeeeeeeee eee eaeeaeeaneeaeeeseeeeeeeeeeeeaeeaaeaneeeeeaseennes 44 Factory default parameter setting table ccsuussssssssss eee 44 1 Introduction Thank you for choosing DALI Instruments LT3 or LT7 hand held infrared thermal imager Model Identification LT3 imagers use the detector with 25um 160 120 and measurement range from 20 C 350 C LT7 imagers use the detector with 25um 384 288 and measurement range from 20 C 600 C Features LT3 LT7 include the following features User selectable Auto or manual level and span control C F or K measurement scale 11 user selectable color palettes 11 user selectable languages Hot temperature spot m
26. JPEG with original Image storage File format thermal measurement data included Visual JPEG Voice annotation Input via built in microphone up to 60 Voice annotation seconds of digital voice clip per image stored with image Measurement mode Automatic corrections according to user input 32 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Nitamongolansi rarkmistja www pictiko fi info pictiko fi LT7 LT3 Thermal Image Camera User Manual ZHEJIANG DALI TECHNOLOGY CO LTD O 2011 DALI TECHNOLOGY Warnings Cautions and Notes Definitions WARNING Could cause bodily injury or death CAUTION Could cause damage to equipment or permanent loss of data NOTE provides useful information to the operator Important Information Read before using the Instrument WARNING Laser Radiation is emitted from this device Do Not stare into Laser Beam Class 2 Laser 635 nm 0 9mW CAUTION Never point the lens directly toward a strong radiation source ie Sun direct or reflected laser beam etc with power on or power off as damage may result to the thermal detector used inside Permanent damage may result CAUTION The original shipping carton should be kept for use for future transportation Do not drop shake or impact the thermal imager excessively in use or during transportation CAUTION Store the unit in its original case in a cool dry well ventilated area away from strong
27. Lampokamera 1 32 K SIKIRJA LT3 LT7 LT3 LT7 L mp kamera Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 hettammongelannel relenisija www pictiko fi info pictiko fi L mp kamera 2 32 KASIKIRJA LT3 LT7 KAYTTOOHJE Varoitukset huomautukset ja kommentit Varoitus Laitteessa on laservalo Ala katso Laservaloon Laser luokka 2 635 nm 0 9 mW Huomaa l osoita kameran linssi voimakasta s teilyl hdett kohti Aurinko tai laser s de L mp kameran ilmaisin voi vahingoittua Se voi my s vahingoittua vaikka kamera olisi virrattomassa tilassa S ilyt alkuper inen toimituspakkaus tulevia l hetyksi varten Varo pudottamasta tai t rist m st kameraa k yt ss tai kuljetuksessa S ilyt laitetta alkuper isess laukussa viile ss hyvin tuuletetussa tilassa v ltt en voimakkaita s hk magneettisia kentti Suojaa linssin pintaa likaantumiselta Aseta linssin suojus p lle k yt n j lkeen Muista tehd otetuista kuvista varmuuskopiot Parhaan mittaustuloksen saaminen edellytt k ynnistyksen j lkeen stabiloitumisaikaa 3 5 minuuttiin Kamera on kalibroitu tehtaalla Suosittelemme kalibrointia 12 kuukauden v lein D Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Maltamnongelannal roukaiskj www pictiko fi info pictiko fi Lampokamera 3 32 KASIKIRJA LT3 LT7 e l avaa kameran kuorta Laitteessa osia joita k ytt j voisi huo
28. NIMIN NM NlN 15 3 2 Battery safety and USAGE 00 cccccccccccscsscsscsseseescsscsecseesceacsscsecseescsecsecseesssatses 16 333 OUICKaceess mmm aN AMA MINTS MIN se ena ena 17 3 3 1 Capture an IMAGE ccc cc a a a a na a seas aseen 17 3 3 2 Temperature measurement cooooooooni a a ee eee 17 3 3 3 Freeze and save IMAGE eee ccccceccescsseseesesecsscsesseseesecsesseeeseessssssseneens 19 3 3 4 Viewing stored IMages seeusssssssssess ee essee eee 19 3 3 5 Export saved images c ooooososssss e es se esseen 20 4 Operation JUIdEe ussmuusu muuan n uaa nananana aan an nananana nananana nannaa Kaan anna 21 4 1 Graphic interface description uouuosssssss e eee 21 4 1 1 Screen graphic interface euouussssnsns enne see seen 21 41 2 Main Men sosro KN nin Aes Aoi Rie ss n 22 4 1 3 Dialog DOX asics eee ee RB y y ky y sty ytyt 22 4 1 4 Prompt box interface cece oo aia 23 42 Measureme amp ntismimeamieesmssektt KNININ NNN RUNN N ssi 23 4 3 Auto Manu lly ssmsssilass ma Sa SATAAN RR 25 4 4 SetUpmenUlmmmesmae ILY ENTISEKSI MINAN 25 4 4 1 Measuring Setup oon a a a a a aa ea asenne 26 4 42 Adjustment SetUP sm ussmsss AN A nA A NNN ET T T s 27 AAB Analysis SetuD s smumm se nA IA T A RA AAA N M NK 28 4 4 4 Date Time SEtUD smsmmsmasssssun amen a MSN esa aes 29 4 4 5 System SETUP 200 eee oo ea aa a a a aa aan a eaa REA 30 4 4 6 System Info ems a nain naam stat TENNE SEN 31 AA
29. Oy 20520 Turku 02 2514402 I voidan www pictiko fi info pictiko fi L mp kamera 20 32 K SIKIRJA LT3 LT7 Asetuskehys P valikossa valitse Setup gt Adjustment ja paina Hyv ksy jolloin asetuskehys tulee n yt lle Voit asettaa emissiokertoimen l mp tilakorjauksen ja ulkoisen l mp tilan Yl a Alas nuolilla valitse muutettava suure ja muuta vasen oikea nuolilla e Emissiokerroin Materiaalin emissiokerroin riippuu materiaalista l mp tilasta ja pinnan laadusta oletusarvo on 0 96 Liitteess A on taulukko eri materiaalien emissiokertoimesta Huomaa ett kun emissiokerroin pienenee heijastus kasvaa Pienill emissiokertoimen arvoilla pinta heijastaa ymp rist n s teily e Customize Valitse materiaali luettelosta e Correct L mp tilan korjaus e Ymp rist n l mp tila Kun Ambient Temp on valittu k ytt j voi antaa ymp rist n l mp tilan k sin 20 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 atnamnongelansl radenisija www pictiko fi info pictiko fi L mp kamera 21 32 KASIKIRJA LT3 LT7 Analyysiasetukset Paina Menu gt Setup gt Analysis ja Hyv ksy Analyysi kehys tulee n yt lle K ytt j voi asettaa l mp tilah lytyksen h lytysrajan h lytyksen v rin isotermin l mp tilan ja isotermin v rin Yl s Alas painikkeilla valitaan kohde ja Vasen oikea painikkeilla muutetaan sis lt H lyytys laukeaa kun mittauspisteen l mp tila ylitt asetetun l
30. R object The new IR object must link with the needed infrared files to be able to display the infrared thermal image and do all kinds of analysis if a previous infrared image has been link on the new image will replace the previous one There are two way to do the link 10 By menu Move the mouse into the IR object and click on the right button an analysis submenu will popup as below Cut Ctrl x Copy Ctrl C Paste Ctrl P Delete Del Open Save As SaveBmpwithAnalysis Save wave Setting Scale Limits Remove Analysis Voice Comment Line Filtering Show GED Object Order gt Fig oo Click on open in the submenu the window with the DLI extension infrared thermal image files will popup for preview show as below change the file path or select the relative infrared file click on open the extension of the infrared thermal images is DLI 22 Dali infrared analysis report software DL Reporter User manual Look in yj M031220 7 cf EI File name M143152 Files of type PICTURE DLI FE Cancel r Image Create Date 2003 12 20 Create time 14 31 52 Image size 320 240 Play voice Fig oo 20 By double click on left button to open In IR object area double click on left mouse button the image selection window such as above will popup select file which need to link on and press open 4 3 3 Analyze IR object 4 3 3
31. Record function allows up to 60 seconds of recording time and may be stopped at any time by pressing the Confirm key 34 If the TF card is not installed the display will prompt the user to install a SD card Please Install SD Card C i a 35 4 5 3 Save Setting The Save Setting menu allows enable disable of the CCD Camera and voice recording Press Confirm key to activate the main menu Select File gt Save Setting press Confirm key to display the Save Setting dialog box Press Up and Down keys to choose the option Press Left and Right keys to set On or Off Link Save With Link Save On the imager will always save an IR image and a CCD image with every save operation With Link Save off the imager will only save whichever image the camera is viewing at the time of the save NOTE When Imager is in the visible camera mode thermal detector calibration does not occur and may result in lower accuracy images when saved Always save thermal images with thermal camera active when Link Save is ON NOTE When Imager is in Link Save Mode a prompt Please do now move when in link save CCD image previewing will pop up Then thermal image is switched to CCD image user confirm two images whether consistent After confirm Save thermal image is back again Voice Save With Voice Save On the imager will start the voice record cycle after confirmation of the save image No recording will occur
32. SL and L e Add Spot adds up to 2 fixed cursors user adjustable by the cursor editing mode Designated by S1 1 and S2 2 e Horizontal Adds horizontal line measurement to display profile of temperatures along the line Designated by LH Either Horizontal or Vertical can be enabled at one time but not both e Vertical Adds vertical line measurement to display profile of temperature along the vertical line Designated by LV Either Horizontal or Vertical can be enabled at one time but not both e Area adds up to 3 area boxes with min max or average detection within each box Areas can be sized and moved by the user Designated by 1 2 and 3 NOTE To delete a single object press A key to select the object and then press C key to delete 24 4 3 Auto Manually By adjusting the temperature and color corresponding relation users can observe enhanced image quality and easily find and analyze thermal fault There are two operational modes Auto Manually available Press Menu key to activate the main menu and select Auto Manually The low level menu will display the inactive mode followed by a Pressing the gt key followed by the Confirm key will switch to the displayed mode Press A key to select palette or adjust it manually In Auto mode the camera automatically determines the low and high temperature levels to assign to the lower and upper ends of the palette In Manually mode the Operator may ass
33. Setup functions Date time temperature unit language Measurement mode Emissivity correction Variable from 0 01 to 1 0 Sa Pa Automatic corrections according to correction user input Atmospheric Automatic correction according to user transmission input object distance humidity and correction temperature Storage card 2G SD card max 16G Manual Auto single file saving IR and Visual image link saving Thermal JPEG with original Storage mode Image storage File format thermal measurement data included Visual JPEG Input via built in microphone up to 60 Voice annotation seconds of digital voice clip per image stored with image 40 Laser pointer Laser locator Class 2 1mw 635nm red IEC 60 285 Battery type Li Ion rechargeable POREN LR 3 hours continuous operation Power source Battery charging Intelligent charger or power adaptor mode 12V optional to random charge Power saving Auto sleep and auto shut down External power 10 15V DC Operating ROH o temperature Sogo hoes 90 Environment Humidity Operating and storage lt 90 non condensing Encapsulation IP54 Drop test 2m Physical Weight 1kg characteristics Dimension 105 245 230mm SD card slot Micro SD card slot interface External DC input YES Video output YES USB Image measurement data transfer The information contained in this document is subject to cha
34. T SAMAN ieee saan 10 2 3 2 DTaWINg toolbari ss iisssss es ass s as a sala ees Es TV KN Kaan ea Vasa ass aate 10 2 3 3 Pattern toolbar ena Kea Ken A ATI KI Ke e Ia eaten 10 2 3 4 Analysis toolbar uoususss a a ea a seen 10 2 39 Pagertoolba 0ssss s L NES VSL VASA Sas 10 2 3 6 Objects toolbakisssissasss i E WORE OS ee 11 3 Stat to USE 110005 am n SINN n am ean Tam a naan a nen A 12 IA Gl Rots Kol TEW O Oa insestist m rt 12 32 Open Up Saved Teolosia renerne n n Ms sainkaan ns msn 12 FD DAVE ME POM ea t SIA essed Pee ned eae ad Peed es tad Saunat 13 3 4 Save as TEPOMt neoon rison NIMENI A ISIN Tian 13 3 5 Save as templates uouusu a aa aa aa aa aa aa aa naan aeaeesn 14 3 6 Export the report as WORD file osuosss o a a aa aa aa aa aan aeeeeen 14 3 7 PIIN SETUP assassines ee EEA Seb enin k et ee eee eds 14 3 8 Print preview x2 2 svds Gee EE a ed KI EUNKAMI NK nak sa 15 3 9 PIIiUTOPOftim NT eed eA Ee eek eee eee 16 3 10 Batch Process ac setae ses hed bate ad nt suin tea ta ed aed it had ae 2 ae ed ea 16 3 11 DD S NASN NA Stanton NARO NASN NANA ae ane Naar a Matte 19 A ISOS DOM 5 coded s NN Tha A TTA se TIAINEN SIA SAIVAT ONI PDN EISS VTI LNN SATASIA 20 4 1 System interface sivccccsccscestccsavcidsccssceesessvetdicceecessesscenessivacesdesutedssdvecassaveceudssonseaesaveueveesisecs 20 4 2 Composing of report contents uuoousssss s n a e e a na Kaa a Ka Kaanaa eaa eeeet 20
35. a fs Mittauspisteet alueet ja linjat Nama iz ba pitaa lisata kohdassa Measurement ja l W NA V ripaletin valinta 4 J LYN L mp tila alueen leveys ja taso n b Pitk ll painalluksella gt 5 s SEA k ynnistyy sis inen kalibrointijakso A ee C kamera painike Valikossa ollessa C kumoaa voimassa olevan toiminnon Kun kuva on pys ytetty C painike palauttaa jatkuvaan kuvaukseen Muutoin C painike vaihtaa l mp kuvan ja n kyv n valon kuvan v lill Kun parametri on valittuna C painike poistaa valitun mittauksen S Pys yt ja tallenna Yksi painallus pys ytt kuvan Tallenna kuva painamalla navigointipainikkeen Hyv ksy painiketta C palauttaa jatkuvaan kuvaukseen Jos nitallennus on valittavissa nitallennusvalikko tulee n kyviin 9 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 I voidan www pictiko fi info pictiko fi L mp kamera 10 32 KASIKIRJA LT3 LT7 5 Navigointipainikkeet Sis lt v t nuolin pp imet ja Hyv ksy painikkeen keskell Kuvatilassa yl s alas nuolilla voi valita zoomin x2 tai poistua zoom tilasta Valikkotilaan menn n painamalla Hyv ksy painiketta jolloin esille tulee valikko Valitse yl s alas nuolilla valikko ja paina Hyv ksy painiketta esille tulee alivalikko josta voit valita toiminnon ja hyv ksy painikkeella saat toiminnon esille 6 Liipaisin pikavalinta Liipaisimella k ynnistet n laser t ht in Pis
36. aa eaa saaneen 31 4 7 Use tabletool 0 mass NASSE NA STE EN RANTEEN RAT RONA NAKIT si E 33 4 3 PIofiletoolis mmmskst m m ean ent EE unen n enin Rans ska ele 35 4 9 Use histogram analytic tool u suosuss e e a a n na a na naene na Kaanaa a naan aeaean 37 4 10 General operations Of object oououussu a a n na na naa a na Ka naene a na eaean 38 4 11 Pase Operations x secs carnitine SINA NA NM Nu na inan 39 5 Use USB mm STEIERT AIN TEINI KIN de eda ea lav TAVIS tg SS ada boas ASNT OSI Ns 41 Dali infrared analysis report software DL Reporter User manual 1 Introduction Welcome to Dali Thermal Images Analysis Report Software We are confident that Dali Thermal Images Analysis Report Software will become the friend of you and your thermal image camera We have accumulated more than ten year experiences to participate in design and create Dali Thermal Images Analysis Report Software Those experiences are our own and also from the feed back of our customer Hope you enjoy the cheer of using Dali Thermal Images Analysis Report Software to create your inspection report and the merits of the unique functions of Dali Thermal Images Analysis Report Software 1 1 Copyright Zhejiang Dali Technology Co Ltd reserved all rights of Dali Thermal Images Analysis Report Software No parts of the software may be reproduced or copied without the prior written permission of Dali Technology 1 2 Liability Zhejiang Dali Technology
37. an define the trigger key function from Laser Spot Temp Area Temp Save key and IR CCD gt Laser Allows user to Turn on and turn off the laser sight gt Spot Temp Adds or deletes Spot Measurement 30 gt Area Temp Adds or deletes Area Measurement gt Save key Initiates the save routine gt IR CCD Switches between IR image and CCD image e Video Mode Allows selection of PAL or NTSC video output e Standby Time Allows user to select None 2 5 10 or 15 minutes If no button depressions are made during the set time the camera will turn off the screen automatically to prolong battery life Press any key except power key to reactivate the screen If set to None the function is disabled o AutoOffTime Allows user to select None 2 5 10 or 15 minutes If no button depressions are made during the set time the camera will turn off the main power automatically to prolong battery life If set to None the function is disabled When StandbyTime is enabled AutoOffTime will start calculating from StandbyTime 4 4 6 System Info System Information Model No LT7 Serial No 2317012001 Version 17 vV1 00 Manu Date Aug 31 2012 Press Menu key to activate the main menu Select Setup gt Sys Info and press Confirm key to open the System Information dialog box It displays the Model number Serial number Version number and Date of Manufacture 31 4 4 7 Factory Default It is used for resetting factor
38. ard is inset in the port the computer system will recognize it as movable USB disc please use infrared thermal image analysis report software to process For DL 770 serial products connect the USB tune on the camera open the infrared thermal image analysis report software the movable USB disc will show up the data then can be operate on DL 770 detail operation process Driver Installation Instruction For Windows XP Installation process 1 Install the Dali thermal Image Analysis Report Software 2 Connect the device to PC by USB the system will remind as below Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for Cypress EZ USB F lt 2 68613 EEPROM missing If your hardware came with an installation CD gt or floppy disk insert it now What do you want the wizard to do CG Install the software automatically Recommended O Install from a list or specific location Advanced Click Next to continue Ca J Fig 1 1 Follow the instructions circled by red Click on Next the system will popup a security warning as below 41 Dali infrared analysis report software DL Reporter User manual Hardware Installation The software you are installing for this hardware Cypress EZ USB Fx2 68613 EEPROM missing has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is impo
39. by the directional arrow keys When Set Ref is set as Yes the displayed values of other measurements will be their delta from this measurement 3 3 3 Freeze and save image Press S key to freeze the image and select C to exit the operation There are three ways to save the image Press S key to freeze the image and then select Save to save the image or select Cancel to exit the operation Press Menu key to activate the main menu Choose File gt Save and the system will initiate the save cycle With the Trigger parameter located in Setup gt Sys Setup gt Trigger set to Save Key pulling and releasing the trigger key will initiate the save cycle 3 3 4 Viewing stored Images Press Menu key to activate the main menu Choose File gt Open to open the image When image is opened choose Left or Right keys to select the previous or next images respectively If the instrument is in IR mode it will display all IR images of each saved image it will display No Image if there is no IR image for that saved image If the instrument is in CCD mode it will display all CCD images of each saved image it will display No Image if there is no CCD image for that saved image If the trigger is configured to IR CCD mode by Setup gt Sys Setup gt Trigger when in image view the trigger can switch between IR and CCD images for each saved image it will display No Image if there is no IR or
40. d Press Menu key to activate the main menu Select File gt Format and press Confirm key to pop up the below dialog box Press Confirm key to do format press C key to cancel the format DALI IR_6 6 6 38 IR 6 6 6 CAUTION Before formatting make sure all files are not needed or already backed up Data cannot be recovered after formatting If formatting via PC please use FAT16 format 39 5 Technical specifications Technical Specification ems LT3 LT7 Detector Detector type Un cooled FPA micro bolometer characteristics Array size format 160x120 384x288 Field of view min focus distance Spatial resolution 25 x19 0 1m IFOV 2 73mrad 1 37mrad Thermal sensitivity lt 0 08 C 30 C lt 0 06 C 30 nage Frame frequenc 50 60Hz characteristics q y Focus Manual Zoom X2 Spectral range 8 14um Built in CCD camera 1 3 million pixels COMS camera modules Image displa LCD displa 2 7 TFT LCD 320 x 240 Temperature ranges 20 C 350 C 20 C 600 C 2 C or 2 of reading Whichever is greater Accuracy Measurement Automatic manual correction Up to 4 movable spots Up to 3 movable areas maximum minimum and average temperatures Up to 2 movable lines Line profile Isotherms Temperature difference Alarm voice color Measurement Color palette 11palettes changeable Image control Image adjustment Auto manual gain and brightness
41. d immediately after adding a line or by selecting via the A key press the Menu key to pop up the attribute box If measurement line is horizontal press Up and Down keys to move the line location press Left and Right keys to move the reference line If measurement line is vertical press Left and Right keys to move the line press Up and Down keys to move the reference line In area measurement editing mode activated immediately after adding an area or by selecting via the A key press the Confirm key to pop up the attribute box Select in the attribute box the parameter to be edited either size or position Press the four navigation keys to move the area location or change the size of the area 6 Trigger Shortcut key The trigger key serves as a shortcut to access the following functions Laser Pulling trigger activates laser sight and releasing deactivates it Spot Pulling and releasing trigger adds a spot Pulling and releasing trigger again removes the spot Area Pulling and releasing trigger adds an area Pulling and releasing trigger again removes the area Save the same with S key pressing to initiate a Save cycle IR CCD Pulling and releasing trigger toggles between the IR image and the CCD image 7 Microphone Used for recording a voice message with the Saved image See Section 4 5 3 for details 2 2Interface i
42. e Time dialog box User can set Year Month Day Hour Minute and Second Press Up and Down keys to choose menu items Left and Right keys to modify the item contents NOTE If the imager is not used for a long period the system clock may need reset due to the internal battery being depleted 29 4 4 5 System setup Language Auto Calib Brightness Trigger Video Mode PAL StandbyTime Min AutoOffT ime Press Menu key to activate the main menu Select Setup gt Sys Setup and press Confirm key to open the System Setup dialog box User can set Language Auto calibration LCD brightness Trigger assignment Video mode Standby time and Auto off time Press Up and Down keys to choose menu items Left and Right keys to modify the item contents e Language Select system language from 11 English Spanish French German Italian Portuguese Korean Japanese Russian Simplified Chinese and Traditional Chinese e Auto Calibration Select Auto Calibration and press right arrow key Auto Calib mode dialogue box will pop up User can select from 3 modes long short or customize Customize can guide user to set the time interval for auto calibration Range is O which is Off and 30 to 600 in 1 second increments Auto calibration is used to improve image guality and measurement accuracy during use LCD Brightness User can select the brightness of LCD display with choices being 20 40 60 80 and 100 Trigger User c
43. e system will open up the converted WORD file Annotate If you want to use this function the Microsoft Word software should been installed in your PC The system convert the infrared images analysis report into WORD file because of the operate system there might be some different of typesets and fonts and those will need adjusted by user 3 7 Print setup The user can change the size of the pager to suit your needs select file print setup in submenu the standard Windows print setup dialog box will popup such as below Dali infrared analysis report software DL Reporter User manual Print Setup 2 x Printer Name Epson EPL 5600 Properties Status Ready Type Epson EPL 5600 Where LPTT Orientation Portrait Landscape Network Cancel Fig oo 3 8 Print preview User can view the created report in two ways 10Click on the amp button on the toolbar 20By select file print preview in submenu the preview interface is as below Tu kam 4850 ruorin Jar am emme jas Fig oo Dali infrared analysis report software DL Reporter User manual 3 9 Print report User can print out the report in three ways 10Click on the S button 20By select file print in submenu 300On the preview interface click on print directly the standard print dialog box will popup show as below Prine IPA r Printer Properti
44. ea or line by pressing MENU and selecting Measurement Press CONFIRM and scroll left or right to select the proper measurement parameter Aim the cursor indicator onto the target object on the screen The temperature will be displayed in the upper right corner of the screen For highest accuracy measurements force a calibration cycle by pressing the A key for 5 seconds until Calibrating appears in upper left portion of display If you want to measure the current thermal image in detail press S key to freeze the image for on screen analysis Save the image if future analysis is desired For details see Section 4 If the target object s temperature is lower or higher than the limits of the camera it will display lt XXX or gt XXX with XXX being the min or max temperature of the selected range To modify the measurements attributes select the measurement parameter and then press the Confirm key The screen will display the settings dialog box The below figures are spot line and area measurement respectively Spot settings include emissivity and reference temperature When Set Ref is set as Yes the displayed values of other measurements will be their delta from this measurement Area settings can modify the emissivity area measurement type and area move parameter Measurement types are Min Temp Max Temp or Average Temp Area Move parameter choices are Position or Size The selected parameter will be adjusted
45. easurement Cold temperature spot measurement 4 removable spot measurements High temperature Alarm setting T Reflect Reflected temperature compensation 2X digital zoom Freeze screen for viewing current image Video Output NTSC or PAL 3 Areas measurements 2 lines measurements Image storage via TF card CMOS visible image and storage Audio recording Isotherm Alarm T Correct Measurement Offset correction Built in Emissivity Table list of common materials 6 Upgrades and Options LT3 amp LT7 Series models are factory upgradeable for Wide Angle or Telephoto Lenses Applications Preventive maintenance Power industry Power line and power facility thermal state checking problem and defect diagnosis o Electrical system Identify potential circuit overloads Mechanical system Reduce downtime and avoid catastrophic failure Construction science e Roof Quick identification of water penetration problems o Structure Commercial and residential energy audits Moisture detection Determine root cause of moisture and mildew Evaluation Evaluate the resolution to ensure the area completely dry Others e Iron and steel industry Inspect steel refining and rolling processes diagnose hot blast stove defects detect the embryo temperature of armor plate etc e Fire fighting Forest fire prevention and detection of latent ignition source Preventive detection on specific materials of auto ignition Detection
46. en resolution 1 5 1 Recommend hardware configuration PENTIUM 1 4GHzT CPU or higher 256 Mbytes or higher system memories 20G or higher hard disc space 1024x768 or higher for the screen resolution 1 5 2 Operating system Dali Thermal Images Analysis Report Software is compatible with Microsoft Windows2000 Windows XP The multi language version software is under developing 1 6 Software installation Following is the step by step description of install the Dali Thermal Images Analysis Dali infrared analysis report software DL Reporter User manual Report Software into your PC and also the preparations before use the software Dali Thermal Images Analysis Report Software is installed by using of Setup programs The Setup program will guide you through the installation process When install please inset the CD ROM into your PC find and run the setup exe in the CD directory The name of Dali Thermal Images Analysis Report Software directory is preset and can be changed during the installation Step onel Welcome interface after run Setup EXE InstallShield Wizard j xj Welcome to the InstallShield Wizard for Dali Infrared Reporter The InstallShield Wizard will install Dali Infrared Reporter on your computer To continue click Next lt Back Cancel Step two Select next the system will ask for the user name company name and the Fig O O serial number InstallShield Wizard
47. erence temperature When Ref Temp is enabled this item is editable A fixed temperature may be entered as the reference temperature or select a measurement object in Ref Temp 4 4 2 Adjustment setup Press Menu key to activate the main menu Select Setup gt Adjustment and press Confirm key to pop up the Adjustment dialog box User may set emissivity temperature correct and ambient temperature Press Up and Down keys to choose different items Left and Right keys to modify the item contents o Emissivity The emissivity of a given material will vary with temperature and surface finish If not set manually system will use the default value Appendix A provides emissivities of common materials o Customize Select material from pre defined list via left and right keys o Correct Temperature correction setup e Ambient temperature when Ambient Temp is enabled user can input the value of ambient temperature 27 4 4 3 Analysis setup Set Alarm Temp Alarm Color Isotherm Color Isotherm Temp Press Menu key to activate the main menu Select Setup gt Analysis setup and press Confirm key to pop up the Analysis dialog box User can set temperature alarm alarm temperature alarm color isotherm color isotherm temperature and isotherm width Press Up and Down keys to choose menu items Left and Right keys to modify the item contents An alarm is triggered when a measurement cursor s measurement meets or exceeds t
48. es Name Status Ready Type Epson EPL 5600 Where LPT1 Comment Print to file r Print range Copies All Number of copies 1 H Ceh Cancel Selection Pages from 1 to 1 Fig oo 3 10 Batch process The system can process a serial of images if the requirements are similar and based on a template to create a batch of same type of reports This will improve the work efficient enormously By select file batch in submenu the dialog box will appear such as below Dali infrared analysis report software DL Reporter User manual Fig oo By select report or picture a batch setting dialog box will appear show as below Batch setting E el tat P i Fig oo A saving path or pictures that need to process can be selected If picture is selected click on next the picture setting dialog will appear such as below 17 Dali infrared analysis report software DL Reporter User manual PIC Batch Setting mTransfer type Palette C No palette Palette type Palette1 gt Fig oo The Palette or No palette is selectable for pictures and also the palette type is selectable Click on OK to confirm this will automatically create the pictures that has been set If the report has been selected click on next the select template path dialog box will appear such as bel
49. eters setup The system allow user setup their own entirely parameters of relative infrared object such as emmisivity ambient temperature distance and humility It also allows user to setup the individual analytic parameters such as emmisivity distance and pattern of display Move mouse to corresponding infrared image click on mouse right button to popup infrared image analysis submenu select the setting this will allow user get into the parameters setting window There are Image Object Parameters Analysis Palette settings 26 Dali infrared analysis report software DL Reporter User manual 4 3 4 1 Image display setup LM g Image Dbject Parameters Analysis Palette IR image V Show scale i Show analysis labels Nee ai Show 3D view 1 iv Update temperatures while moving analysis Fig oo There are three selections for image display as above user can select it according to your needs 4 3 4 2 Thermal images parameters setup set xd Image Object Parameters Analysis Palette Object Emissivity n Relative humidity Object type 70 EI Ref temperature 28 46 E Distance 10 m m Temperature Ambient 28 46 SE Reset Fig oo Show as above the setup for thermal images parameters setup is for all images one off if the individual images do not has the individual setup changing of thermal image 27 Dali infrared analysis
50. etup temperature range for example between 100 and 300 the same color will used to show those temperature range in the infrared thermal image 24 Dali infrared analysis report software DL Reporter User manual Fig oo 4 3 3 2 Modify analysis To modify the infrared object analysis the N button in the object toolbar must keep in active and the infrared object is activated the frame of the object will have eight sizing handles look like black small rectangular If the object is not active click on the object to make it active Move around the mouse on the infrared image the state of the change can be determined by the sharp of the mouse symbol click and held on the left mouse button draw the mouse to modify and move each analysis When the analysis in the active the sharp of the mouse symbol will sort as Move spot Move line move the line entirely Modify line set another spot as centre of the circle to rotate or flex Move rectangular move rectangular entirely or change size Move circle move circle entirely or change size J Modify rectangular change rectangular size according to arrow direction Change circle change circle size according to arrow direction Isotherm analysis Move the mouse inside the palette of isotherm area the symbol of mouse shows in different sharp there are three ways 1 Mouse in the middle of the palette hold on left mouse button and draw whole section will move along with the
51. hange any settings click Back If you are satisfied with the settings click Next to begin copying files Current Settings InstallShield Fig O Step five The display of this interface means the Dali Thermal Images Analysis Report Dali infrared analysis report software DL Reporter User manual Software has been successfully installed into your PC system InstallShield Wizard InstallShield Wizard Complete Setup has finished installing Dali Infrared Reporter on your computer lt Back Cancel Fig O 1 7 Start the software After complete the installation of the Dali Thermal Images Analysis Report Software please retune to the WINDOWS interface and the Dali software icon should appear as below Dali Infrared Reporter Fig o Double click on the icon the Dali Thermal Images Analysis Report Software will then be started Dali Thermal Images Analysis Report Software will also create the menu icon in the system start menu as below fn Dali Infrared Reporter PJ Dali Infrared Explorer B Dali Infrared Reporter Fig O This icon can also be selected to start the Dali Thermal Images Analysis Report Software Dali infrared analysis report software DL Reporter User manual Dali infrared analysis report software DL Reporter User manual 2 Software interface Dali Thermal Images Analysis Report Software is a standard WINDOWS application program it works under
52. he C key when an image is frozen or being viewed from memory will return to real time measurement status e When notin menu mode or parameter editing pressing and releasing the C key will toggle between the thermal image and the visible CCD camera image e When a parameter is selected such as a measurement cursor pressing the C key will delete the highlighted measurement 4 Freeze Save key Marked S Used for freezing or saving thermal image Press the key once to freeze the image Press Confirm to save the image or Press C to return to real time measurement If Voice recording is enabled Voice comment dialog box will display 5 Menu Confirm key bar Includes Up Down Left Right and Menu Confirm center keys Function varies with operation mode In Menu mode it is used for menu selection Up and Down keys are for same level of menu operation Left and Right keys are for different levels menu operation Confirm key center is to activate the menu and confirm the choice In Image mode press Up or Down key to activate X2 digital zoom The screen will display X2 in the upper left corner Press Up or Down key to return to the original image 11 In Spot Measurement editing mode activated immediately after adding a spot or by selecting via the A key press the Menu key to pop up the attribute box Press four navigation keys to move the spot location In line temperature measurement editing mode activate
53. he Set Alarm Temp setting All pixels above this temperature will change to the color as set in Alarm Color When the Alarm Color is set to None only the audible alarm will sound When using alarms with Area measurements the selected measurement mode Min Max or Average will have to meet or exceed the set temperature in order to trigger the alarm e Temp Alarm Off disables alarm function On enables alarm function and allows setting of Set Alarm Temp and Alarm Color Alarming Temp Sets the alarm detection temperature Only enabled when Temp Alarm is set to On e Alarming Color Selects the color in which the alarming pixels are displayed If set to None no changes are made to the screen s color Only enabled when Temp Alarm is set to On e Isotherm Color Activates the Isotherm display by displaying the 28 image in the set temperature range by the specified color Setting to Off disables the feature o Isotherm Temp Sets the center temperature of the isotherm o Isotherm Width Sets the width of the displayed Isotherm band For example if Isotherm Temp is set to 122 F 50 C and Isotherm Width is set to 1 C the isotherm band will be from 121 5F 49 5 C to 122 5 F 50 5 C 4 4 4 Date Time setup Allows the user to set the system date and time After setting the camera will save the current setting Press Menu key to activate the main menu Select Setup gt Date Time and press Confirm key to open the Dat
54. hlighted in yellow The functions include e Measurement points areas and lines Cursors and lines pressing the arrow keys will move their position Pressing the Menu key will pop up the attribute box Pressing the C key will delete the selected parameter Areas Arrow keys adjust the attribute specified in the pop up attribute box Pressing the Menu key will pop up the attribute box In this box the user can select to adjust either position or size of the area After selection the arrows will then adjust the attribute e Color Palette Pressing the left or right arrows will scroll through the available color palettes displaying their name above the palette The selected palette will become active after about 3 seconds of selecting it and will be set as the default power on palette e Level Span values Pressing the left or right arrow will reduce or increase the Span and pressing the up or down arrow will reduce or increase the Level If the unit is in Automatic mode modifying any of these parameters will select Manual mode b The second function performed is to force an internal calibration cycle 10 This is performed by pressing and holding the A key for 5 seconds or more The camera will make automatic correction to get the most accurate thermal measurement 3 Cancel Camera key Marked C e Pressing and releasing the C key cancels the present operation when in Menu mode e Pressing and releasing t
55. ictiko Oy 20520 Turku 02 2514402 Tee a e e www pietiko fi info pictiko fi L mp kamera 7 32 KASIKIRJA LT3 LT7 e Palontorjunta Mets palojen ehk isy ja mahdollisten syttymisen l hteet M r ttyjen aineiden itsesyttymisen ehk isy Kipin ivien l hteiden etsint e Terveys Ihmisruumiin pintal mp tilan kartoitus e ljyteollisuus ljyputkien tilan seuranta Materiaalien pintal mp tilojen seuranta eristyksen tarkastus jne Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 ST Ee www pictiko fi info pictiko fi L mp kamera 8 32 K SIKIRJA LT3 LT7 Varusteet jotka kuuluvat toimitukseen L mp kamera varustettu rannelenkill e Kantolaukku e Videokaapeli e Li akut 2 kpl e K ytt ohje analyysiohjelma ja raportin teko ohjelma e LI akkujen latauslaite e K ytt ohje e Linssin suojus e TF kortti e TF kortin lukija e USB kaapeli Lis varusteita e 0 5x laajakulmalinssi e 2x teleskooppilinssi e Verkkolaite TAhfiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Se Ee www pictiko fi info pictiko fi L mp kamera 9 32 KASIKIRJA LT3 LT7 2 Kameran toiminnot Toimintopainikkeet 1 p lle pois painike 2 Select Auto A 5 Kytke p lle painamalla 3 s ajan Huom Kun kytket kameran pois p lt odota 10 s ennen uudelleen k ynnistyst a Lyhyt painallus alle 2 sekuntia valitsee parametrivalikon jossa voi muuttaa seuraavia toimintoj
56. ign the lower and upper end values to enhance the image quality by adjusting the temperature to color relationship In Manually mode pressing the left or right arrow will reduce or increase the Span and pressing the up or down arrow will reduce or increase the Level 4 4 Setup menu Measurement Level Span 25 4 4 1 Measuring Setup Temp Range Lens Temp Unit Amb Temp Ref Type Ref Temp Press Menu key to activate the main menu Select Setup gt MeasureSet and press Confirm key to pop up the Measuring Setup dialog box User can view or set temperature range lens type temperature unit ambient temperature reference type and reference temperature Press Up and Down keys to choose different items Left and Right keys to modify the item contents e Temp Range Select Temp Range according to target temperature LT7 low Temp Range 207180 C or high Temp Range 100 600 C LT3 20 7350 C o Lens Select Standard Telephoto or Wide Angle A mark will display when Telephoto or Wide Angle is selected e Temperature unit Select between C F and K scales e Ambient temperature Camera will display internal ambient temperature automatically Used for automatic calibration and is not user editable o Reference type When Ref Type is On the temperature of the measured object displayed by the cursor on the screen is the difference from the selected reference or the reference temperature set below 26 o Ref
57. ill explain one by one here under 20 Dali infrared analysis report software DL Reporter User manual 4 3 Operations of IR object The IR object are used to display the infrared thermal pictures it also can be used to analyze and show the temperature of spots lines and area rectangular and circle and data such as highest or lowest temperature It can be used to playback the voice on the saved infrared thermal images and display the corresponding CCD pictures The system focus on create reports for infrared thermal images This is the main subject of this software 4 3 1 Create IR object Use the mouse to click on infrared thermal image button in the objects toolbar and allow the button in active draw the mouse and move it to the plain space on the page the mouse symbol will become a cross hair click the left mouse button and held the button draw the mouse a changing size rectangular will show on the page release the mouse a new IR object will be created on the page Such as showed below the large rectangular with eight black small rectangular is the new IR object without the infrared thermal image There is no amounts limit to create object but it will be limited by the capacity of system memory PPI k cain x 4 ee kJ TELI te JAMA I v t A mt ja AH EI 7 Bae AEn 4m T Bee cepa fete za Fig oo 21 Dali infrared analysis report software DL Reporter User manual 4 3 2 Link I
58. ject to show the result move mouse on the linear analysis object click right mouse to popup menu and select setting to enter into connecting window as below Characters setting can be used to setup the display effect such as whether to show gridline and legend whether to display the linear maximum and minimum temperature or the instant messages 35 Dali infrared analysis report software DL Reporter User manual Properties xj Settings Colour m Options Temperature axis r Compart line colour V Gridlines C IR Scale a NN v Legend i Auto 2 Line stamp Fixed v Result table Max Profile display 45 a je Align left Min C Stretch 15 1E Cancel Fig 36 Color setup choose the infrared object that needed to be analyzed and the beeline in the object as well as the corresponding color Show as picture below select relative infrared object number and line number and press Ok to confirm User can choose several lines to analyze at one time xi Properties Settings Colour IR image number il Lines Cancel Fig 37 The corresponding linear analysis result should show on the main interface Show as below there will be line maximum minimum and instant temperature and line number on the object 36 Dali infrared analysis report software DL Reporter User manual LINE MAX MIN Cursor Line01 5
59. ka vastaa kiinnostuksen kohdetta Manuaali toiminnossa vasen ja oikea nuolipainike s t l mp tila aluetta ja yl s alas painikkeet s t v t l mp tilan tasoa Setup asetukset Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pictiko fi info pictiko fi L mp kamera 19 32 K SIKIRJA LT3 LT7 Mittausasetukset Aktivoi p valikko Menu painikkeella Valitse Setup gt MeasureSet ja paina Hyv ksy painiketta N kyviin tulee yll kuvattu dialogikehys Voit asettaa l mp tila alueen objektiivityypin l mp tilayksik n ulkoisen l mp tilan vertailutavan ja vertailul mp tilan Valitse muutettava kohta yl s alas painikkeilla ja vasen oikea painikkeilla voit muuttaa sis lt L mp tila alue LT3 aina 20 350 C LT7 20 180 C tai 100 600 C Objektiivi valitse Normaali Tele tai laajakulma N yt ll n kyy milloin tele tai laajakulma on k yt ss L mp tilayksikk C K tai F Ulkoinen l mp tila Kamera n ytt sis isen ulkoisen l mp tilan Tata k ytet n automaattisessa kalibroinnissa eik k ytt j voi sit muuttaa Reference Type Kun Ref Type on On mittauspisteen l mp tila n yt ll on valitun referenssin ja pisteen l mp tilan erotus Reference Temperature Kun RefType is On t t referenssil mp tilaa voi muuttaa joko kirjoittamalla l mp tila tai valitsemalla mittausobjekti bike Oy Tykist katu 4 B 310 Pictiko
60. ltaa Korjaus vain valtuutetun henkil n toimesta 2 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Minausongsimasi ratkaisija www pietiko fi info pictiko fi L mp kamera 4 32 K SIKIRJA LT3 LT7 Sis llys Varoitukset huomautukset ja kommentit ouoousssssssssn annakaan aaaaaaean 2 Sis llys a Virhe Kirjanmerkki ei ole m ritetty JOI ALO sergisine E a E i 5 L amp kameramallit ees Ea EEE EEEE E SEN 5 Toiminnot molemmissa malleissa cccccccccsseeeeeceeeeeeeeeeeeaaeseeeeeeesaaeeeeees 5 OPIO s a As S eaa S eee ere 6 OVNI SG eae i Keane E EE nesteet a vitsoset 6 Ennakoiva MIKO O m mausssstamms ammeessa saita envu EREE EEEE saa EEES kut 6 Rak nn kset ase cece iets a a EA A E E musta 6 NIU e a suetaneiasevatsvecuideuareduiadeteatdudsetnnceevetdiuatesiauapiaied 6 Varusteet jotka kuuluvat toiIMItUKS N cccccceesseeeeeeeeseeeeeeeeesuaeeeeeeeeesaees 8 Lis ayar steita saeson E E EEEE TERT 8 Kameran t0iMINNOl sseni aaia ea eaa Naa AEEA 9 ToimintopainikKe etenee eE E E R 9 PTT ODA eee ota ansan Aaa a cence cate seca ahiee ae ah enna aneeeeten es 11 4 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Miumnongelannal e e www pietiko fi info pictiko fi Lampokamera 5 32 KASIKIRJA LT3 LT7 1 Johdanto L mp kameramallit LT3 kamerat k ytt v t 25 um160x120 detektoria jonka mittausalue on 20 350 C LT7 kamerat k ytt v t 25 um 384x28
61. mp n kohtaan e Add Spot lis max 2 kiinte kursoria Niit merkit n S1 1 ja S2 2 N iden pisteiden l mp tila n ytet n e Horizontal lis vaakasuoran viivan jonka l mp tilaprotfiili n ytet n Nimi on LH e Vertical Lis pystysuoran protiiliviivan LV LV ja Lt ei voida n ytt yhtaikaa e Area lis max 3 aluetta joiden max min tai keskiarvo n ytet n Alueiden kokoa ja paikkaa voidaan muuttaa Nimitys 1 2 ja 3 Huom kohteen voi paistaa valitsemalla kohde A painikkeella ja sitten painamalla C painiketta Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pictiko fi info pictiko fi L mp kamera 18 32 K SIKIRJA LT3 LT7 Automaattinen Manuaalinen S t m ll l mp tilan ja v rien vastaavuutta k ytt j voi parantaa kuvan laatua ja helpottaa l mp vikojen etsint ja analyysi T m n voi tehd joko automaattisesti tai manuaalisesti Paina Mennu painiketta jolloin p valikko tulee n kyviin ja valitse Auto Manually alivalikko n ytt Auto jos manuaalinen toiminto on k yt ss ja Manual jos Atutomaattinen on k yt ss Paina nuoli oikealle ja Hyv ksy jos haluat vaihtaa toiminnon Automaattisessa toiminnossa kamera valitsee automaattisesti l mp tila alueen kattamaan alimman ja ylimm n l mp tilan Manuaali toiminnossa k ytt j voi valita alimman ja ylimm n l mp tilan vastaamaan sit l mp tila aluetta jo
62. netaasetetun ajan kuluessa kamera kytkee n yt n pois p lt akkujen s st miseksi Mink tahana paikkeen painaminen aktivoi n yt n e AutoOffTime Voit valita None 2 5 10 tai 15 minuuttia Kamera kytkeytyy pois p lt akun s s miseksi Jos StandbyTime on valittu AutOffTime aloittaa STanby Timen j lkeen J rjestelm n tiedot Paina Menu gt Setup gt Sys lnfo ja paina Hyv ksy N et Mallin Sarjanumeron Version ja valmistumis ajan 24 Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pietiko fi info pictiko fi Lampokamera 25 32 KASIKIRJA LT3 LT7 Tehdasasetukset Tassa palautetaan laitteen tehdasasetukset Paina Menu gt Setup gt Default ja Hyv ksy Jos haluat palauttaa tehdasasetukset paina Hyv ksy ja jos et paina C painiketta Liitteess B on yksikohtainen luettelo tehdasasetuksista Tehdasastusten palauttaminen poistaa kaikki k ytt j n asettamat parametrit Tehdasasetusten palauttaminen EI poista muistikortille tallennettuja kuvia 25 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 hettammongelannel relenisija www pictiko fi info pictiko fi Lampokamera 26 32 KASIKIRJA LT3 LT7 Tiedostot Avaa Paina Menu gt File gt Open ja paina Hyv ksy Tallennetut kuvat tulevat n yt lle Vaihda kuvaa Vasen Oikea painikkeilla Palaa mittaukseen C painikkeella Kamera avaa viimeisen n ytetyn kuvan tai viimeisen tallennetun kuvan riippuen kum
63. nge without notice 41 Troubleshooting Please follow the table below to diagnose and correct the problem If problem still exists please contact our service department 400 887 1897 automatically Problem Cause amp Solution e Battery not installed or installed incorrectly The vajaat dase Hat siete battery or re install battery nowaron o Battery is out of power Change battery Power off protection is enabled Wait for 5 seconds and reboot o Battery is out of power The camera powers _ off Change battery AutoOffTime option is enabled Set as None Battery depletion is too fast Environmental temperature is too low Rechargeable battery is not charged completely Recharge the battery Rechargeable battery is out of power completely and cannot be recharged Change to new battery No thermal image Lens cover is not removed Remove lens cover In image freeze status Press C key to exit Thermal image is white black White black palette is selected Select normal palette 42 Appendix A Common material emissivity FYI Material Surface Temperature C Emissivity Non oxidized 100 0 20 Aluminum Oxidized 100 0 55 Burnished to Brown 20 0 40 Brass Dull luster 38 0 22 Oxidized 100 0 61 Copper Seriously Oxidized 20 0 78 Oxidi
64. nu will popup as below select properties a configuration dialog box will popup Cut Ctrl x Copy Ctrl C Paste Gtrl P Delete Del Properties Alt Enter Object Order gt Fig 33 In configuration dialog box the cell type and background color can be affirmed show as below 33 Dali infrared analysis report software DL Reporter User manual Properties Fig 34 If select text a text needed can be fill in by yourself if select field an appointed property will automatically connect on according to your selected infrared image and object show as below 34 Dali infrared analysis report software DL Reporter User manual x Format Cells Connect Object Value Picture info Emissivity Camera info Object distance Ambient Spot analysis Atomspheric Line analysis Transmission Area analysis Reference Isotherm analysis IR image 1 Object 1 Cancel Fig 35 4 8 Profile tool The profile tool is use for linear analysis of beeline in infrared object Click on profile tool page the mouse symbol become a cross hair press mouse left button and hold on the button in object toolbar and make it in active move the mouse to plain space on the changing box which indicate the position and size of the object will appear release the button a new linear analysis object will be created The linear analysis object has to link with the corresponding infrared ob
65. ow Select Template path xi Template CAProgram Files DALKDali Infrared Reporter template Demo rpm Select template Cancel Back OK Fig oo After the template has been selected click on OK the corresponding report will be automatically created according to the selected template Dali infrared analysis report software DL Reporter User manual 3 11 Exit By select file exit in submenu the system will popup the confirming dialog box click on Ok to exit from the system 19 Dali infrared analysis report software DL Reporter User manual 4 Use report 4 1 System interface The main system interface is showed in the picture as below on the top it contains main menu common operate toolbar page toolbar word processing toolbar objects toolbar and analysis toolbar The plain space in the interspaces is report working area The best resolution for this software is 1024X768 x ee o s lt lr J A et a a te JAMA I um s lt 4 m ia TH EI 2 H bY Hracsemal 7 a ols nn Soe es mt fuga sin 7 Bae ten Rou Bet emar rra Fig oo 4 2 Composing of report contents The report mainly compose of infrared thermal images and analysis CCD pictures formatted text result lists tables and objects image linear analysis histograms and decorate frames The design of this report is also aimed on arrange the operations of those contents Those contents w
66. pi tapahtuu viimeksi 1 N ytett v n kuvan nimi 2 N ytett v n kuvan tiedostonj rjetusnumero 3 Tallennettujen kuvien kokonaism r 26 Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pictiko fi info pictiko fi SEN Oy Mittausongelimasi ratkaisua Lampokamera 27 32 KASIKIRJA LT3 LT7 Tallennus Toimii samoin kuin Tallenna painike Paina Menu gt File gt Save ja paina Hyvaksy Kuva tallentuu muistikortille Jos et halua tallentaa paina Cancel ja Hyv ksy Voit my s painaa C painiketta Jos Voice Save on valittu asetuksissa nitys alkaa Puhu selke sti mikrofoniin Voit tallentaa 60 sekunnin kuvauksen Tallennus pys htyy painettaessa Hyv ksy painiketta 27 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Niamongolansi rarkmistja www pictiko fi info pictiko fi Lampokamera 28 32 KASIKIRJA LT3 LT7 28 Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pictiko fi info pictiko fi SEN Oy Mriittausongeimasi ratkaisua Lampokamera 29 32 KASIKIRJA LT3 LT7 Tallennusasetukset Tallennusasteuksilla maaritetaan mita tallennetaan Voit valita CCD kameran kuvan ja aanitallennuksen Paina Main gt File gt SAVESetting ja paina Hyvaksy jolloin tallenuastuksen kehys tulee n yt lle Link Save Kun Link Save on valittu kamera tallentaa IR kuvan ja CCD kuvan tallennustoiminnassa Jo link Save on OFF kamera tallentaa sen kuvan joka on n y
67. report software DL Reporter User manual parameters will effect all analysis the analysis which has been solely setup will not be changed 4 3 4 3 Analysis parameters setup Click on analysis in setting window will allow user to setup each parameter the interface is as below User can change the setup of each parameter to select different display effect of analytic image which include color display maximum minimum and average date and also adjust the emmisivity or distance of analytic image If the emmisivity and distance select box has been chosen the corresponding analytic objects will possess of their own sole analytic parameters When objects possess of their own sole analytic parameters the changing of entire thermal image parameters will not change the emmisivity and distance of analytic object press ok to confirm all setup will take effect or press cancel to cancel setup EE 700000 xi Image Object Parameters Analysis Palette 7 Colour Ss I Label Own Object Parameters SP01 Emissivity 1 none dl Distance 10 The analysis label will be marked Isotherm Isotherm Colour muun vj Fig oo 28 Dali infrared analysis report software DL Reporter User manual 4 3 4 4 Palette setup EE 22111 x Image Object Parameters Analysis Palette Pallette1 El Out of range overflow Saturation overflow Sat
68. rtant Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing ET Continue Anyway P STOP Installation Fig 1 2 Click on Continues Anyway until the finish interface appears see Fig 1 3 Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for rad Cypress EZ USB F lt 2 68613 EEPROM missing Click Finish to close the wizard o Finish D Fig 1 3 3 Click on finish the installation has been successful 4 After about 30 seconds depends on the configuration of the PC In the Windows Explore of the Windows system there will be a removable hard disc available therefore the saved images in the device will be available to use Please note 1 Each USB port need a installation individually 201f shows Unknown Device the USB port is not working Please try it late or try another USB port Please note When the removable hard disc appears in the Windows Explore please wait for about 30 seconds before visit this disc otherwise might cause PC system collapse or the files in the device can not been read 42
69. s button move the mouse to the corresponding thermal image and select the starting position of the analytic rectangular mouse symbol as cross hair hold on the left mouse button move the mouse and draw a rectangular release the mouse button in suitable position and a new analytic rectangular will been created upon the diagonal of the start position and release position there is no amount limit on analytic rectangular the system will title the line in order ORect010Rect020Rect03 7and calculate and record the highest lowest and average temperature on this line automatically 5 O Circle analysis after activate this button move the mouse to the corresponding thermal image and select the position of the centre of analytic circle mouse symbol as cross hair hold on the left mouse button move the mouse and draw a circle release the mouse button in suitable position and a new analytic circle will been created upon the start position as the centre of the circle and the distance to release position as radius there is no amount limit for analytic circle the system will title the circle in order Area010Area 020 Area 03 Ciand calculate and record the highest lowest and average temperature on this line automatically 6 Isotherm analysis after activate this button click on the palette in right side of IR object the results will show as the picture the green area is the isotherm area Isotherm analysis is a analytic method that in the s
70. t ll HUOMAA Kun kamera n ytt n kyv n valon kuvaa kamera ei suorita automaattista kalibrointia joten t ll in tallennettaessa IR kuvan laatu voi heiket Kannattaa siis aina tallentaa kun l mp kuva on n yt ll Voice Save Kun Voice Save on valittu kamera aloittaa nitallennus jakson kun kuvan tallennus on hyv ksytty Jos Voice Save on Off asennossa ei nitallennusta tapahdu Auto Save toiminnossa ei my sk n ole nitallennusta Voit my s lis t nitallenteen tallennettuun kuvaan Valitse Voice Save avaa tallennettu kuva ja valitse File gt Save Kamera pyyt antamaan viestin joka liittyy kuvaan Pietiko Oy Tykist katu 4 B 310 20520 Turku 02 2514402 www pictiko fi info pictiko fi Lampokamera 30 32 KASIKIRJA LT3 LT7 Automaattinen tallennus Auto Save toiminto mahdollistaa kuvien automaattisen tallennuksen halutuin valiajoin Kun Auto Save on asetettu 0 ei automaattista tallennusta tapahdu Aseta tallennuksen v liaika 10 ja 3600 sekunnin alueelle 1 sekunnin askelin Paina Menu gt File gt Auto Save ja Hyv ksy Vasen Oikea painikkeilla voit valita tallennuksen v liajan Paina lopuksi Hyv ksy painiketta Tallennetun kuvan poisto Kun kamera n ytt tallennettua kuvaa valitse Menu gt File gt Delete ja paina Hyv ksy Poistodialogikehys tulee n ytt n Paina hyv ksy niin kuva poistuu Paina C jos et halua poistaa 30 Pietiko Oy Tykist katu 4 B 310 2052
71. te Spot tilassa Liipaisin lis pisteen Alue Alue tilassa Liipaisin lis alueen 7 Mikrofoni k ytet n niviestien tallentamiseen 10 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Manoogian raiado www pietiko fi info pictiko fi Lampokamera 11 32 KASIKIRJA LT3 LT7 Liitynn t 1 USB l ht 2 TF kortti miniSD T nne tallentuvat kaikki kuvat Toimitukseen kuuluu 2GB 3 Video l ht 4 Ulkoisen virtal hteen liitin 12V keskiliitin on napa 11 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 hettammongelannel rarkmistja www pictiko fi info pictiko fi L mp kamera KASIKIRJA LT3 LT7 3 Perustoiminnot Akkujen asennus ja vaihto Akut ovat k sikahvassa K nn kansi auki vastap iv n Aseta akku sis n liittimet edell Sulje kansi Varoitus K yt alkuper isi vara akkuja V r n tyyppinen akku voi aiheuttaa kameran rikkoontumisen Kun akussa on noin 5 varausta j ljell n ytt n tulee viereisen kuvan mukainen varoitus ja kamera kytkeytyy virrattomaksi noin 3 s kuluttua l aw Hattery T ss vaiheessa on syyt vaihtaa Please Change Battery akkua ja ladata tyhja akku Akkuja tulisi s ilytt l mp tilassa 20 20 C l mp tilassa Litiumakut tyhjentyv t varastoitaessa Akkuja tulisi ladata ajoittain seuraavan taulukon mukaan L mp tila alle 20 C 6 kuukauden v lein L mp tila alle 45 C 3 ku
72. the Windows XP or Windows 2000 system and tally with the operating of Windows application program This manual is based on the assumption of that you are familiar with the Windows system if it is necessary please refer to the Windows operation manual although some of the characteristics for Windows are also been explained in this manual 2 1 The main interface of Dali Thermal Images Analysis Report Software a 4 27 kt 204 alt Ler J A oe 077 te S2S ns LD ante t a m sa Aad EI Hot KON Frosemwal sau lt 7 Ce 4450 irnn Rou Bee cepa fete ae Fig 8 When the Dali Thermal Images Analysis Report Software has been started the file window of Dali Thermal Images Analysis Report Software will also been opened up The window size shape and toolbar position will open as it had when you last time exit the 7 Dali infrared analysis report software DL Reporter User manual program The window of the Dali Thermal Images Analysis Report Software could be changed in size minimize maximize and move over The top of the Dali Thermal Images Analysis Report Software interface is the title bar underneath that is the menu bar at bottom of the Dali Thermal Images Analysis Report Software interface is the state bar user can select to display or hide the state bar There are six toolbar underneath the menu bar The area below the toolbar is the working space you can work on your report in this space 2 2 Menu bar
73. the position and size of the table will appear release the button a new result table will be created The result table has to link with the corresponding infrared object to show the result move mouse on the result table double click left mouse button a dialog box will popup as below x Connect Object Value Picture info O Created date Camera info Oc dii Parameters reata time Spot analysis O File name Line analysis O File position Area analysis O Ti Isotherm analysis o IR image i Show Difference Temperature Fig 31 Select relative items object message type show in left available messages items for this type show in right Click on OK to confirm the relative parameters will display in the main interface Press cancel the setup will not take effect The result after selection shows as below 32 Dali infrared analysis report software DL Reporter User manual 4 7 Use table tool Click on table tool button in object toolbar and make it in active move the mouse to plain space on the page the mouse symbol become a cross hair press mouse left button and hold on the changing box which indicate the position and size of the table will appear release the button a new table will be created There are two ways to fill the contents in the table 1 user fills in contents and text by themselves 2 link with some infrared object parameters Click mouse right button in the table cell a me
74. ukauden v lein L mp tila alle 60 C 1 kuukauden v lein Akun varauksen pit isi olla alle 50 ennen uudelleen latausta Latauksen tulisi tapahtua l mp tila alueella 0 40 C Varoitus l polta tai tee akkuun reiki l oikosulje akkua Pid akku 12 32 kuivana l anna akkua lasten k siin H vit akku paikallisten s nt jen mukaisesti 12 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 atnamnongelansl radenisija www pictiko fi info pictiko fi L mp kamera 13 32 KASIKIRJA LT3 LT7 Pikaohje Kuvan otto Kun akku on asennettu paina ja pid virta painiketta yli 3 s ajan kunnes n ytt kytkeytyy p lle Noin 50 s kuluttua k ynnistys rutiini on suoritettu ja kamera aloittaa mittauksen Poista linssin suojus ja osoita kohdetta S d et isyystarkennus Jos tarkennus ei ole kohdallaan syntyy mittausvirheit L mp tilan mittaus e Jos n yt ll ei n y mittauksen apuviivoja lis mittauspiste painamalla Menu ja valitsemalla Measurement Paina Hyv ksy ja siirry vasemmalle ja oikealle ja valitse oikea mittausparametri Kohdista piste n yt ll kohteeseen L mp tila n kyy n yt n oikeassa yl kulmassa Parhaimman tarkkuuden saat k ynnist m ll kalibrointijakson painamalla A painiketta 5 s ajan kunne Calibrating ilmestyy n yt n vasempaan yl kulmaan e Joshaluat tarkastella kuvaa tarkemmin paina S painiketta lukitaksesi kuvan analyysi
75. uration underflow Out of range underflow Lo 71 Analysis default A Isotherm 1 Isotherm 2 SSS Invert Fig oo User can select suitable palette Select the needed palette in drop down window press ok the corresponding infrared object will display the infrared thermal image in the pattern of selected palette If invert has been selected the infrared image will display the reverse of high and low temperature mode 4 3 5 Voice playback N If the selected image object has a voice involved in the voice button J in analysis toolbar will be in implement state press this button to playback the voice 4 4 Use CCD image object CCD images are mainly for display the pictures and can be display in BMP or JPG format by put the infrared image and CCD image together your report will be more clear and aesthetic Click on CCD image button led in object toolbar and make it in active move the mouse to plain space on the page the mouse symbol become a cross hair press mouse left button and hold on the changing box which indicate the position and size of the object will appear release the button a new CCD picture will be created There is no amount limit for 29 Dali infrared analysis report software DL Reporter User manual CCD pictures the quantity only limited by the system memory capacity After create the object move mouse on the object click on mouse right button to popup
76. uva on n kyviss voit valita vasen oikea nuolipainikkeilla muistikorttiin tallennettuja kuvia e Jos kamera on IR tilassa n ytet n IR kuva Jos kuvaa e ole n ytet n No Image e Jos kamera on CCD tilassa n ytet n CCD kuva ja No Image jos ei kuvaa e Jos liipaisin on ohjelmoitu IR CCD toimintoon Setup gt Sys Setup gt Trigger liipaisimella voidaa vaihtaa IR ja CCD kuvien v lill e Tallennettujen kuvien katselusta poistutaan C painikkeella Kuvien vienti tietokoneelle e Voit vied kuvat USB kaapelilla tietokoneelle e Voit my s irrottaa muistikortin ja siirt kuvat kortinlukijan avulla tietokoneelle 14 Pietiko Oy Tykist katu 4 B 310 Pictiko Oy 20520 Turku 02 2514402 Miuausongcimasi rakaisi www pictiko fi info pictiko fi Lampokamera 15 32 KASIKIRJA LT3 LT7 4 K ytt opas Graafisen k ytt liittym n kuvaus N yt n kuvaus z g ye m 1 Logo DALI i v 10 2 Toimintatapa 2 3 Pistemittaus 3 10 11 12 13 14 15 Valittu pistemittaus Emissiokerroin Minimi l mp tila valkoinen hiusristi keltainen risti ja paletin V ripaletti Max l mp tila paletin Akun tila Mittaustulos Keltaisella kirjoitettu on valitun pisteen mittaustulos Toisen pisteen mittaustulos L mp tilayksikk Ulkoisen linssin laatu 0 5x laajakulmalle ja 2x telelinssille Muistikortin symbooli SD kun kortti on paikallaan
77. with Voice Save set to Off Voice save setting is ignored with the Auto Save function NOTE To add voice comment to an image enable Voice Save open the image to be modified and select File gt Save The imager will prompt you to record the message and the new image will be assigned a new image number while the old image will remain unchanged 36 ATC 4 5 4 Auto Save Auto Save allows the camera to automatically save images at a user specified interval Voice annotation is inactive with Auto Save With Auto Save set to O the function is disabled To enable select 10 to 3600 seconds 1 hour in 1 second increments To set press Menu key to activate the main menu Select File gt Auto Save press Confirm key to display the Auto Save dialog box Press Left and Right keys to set the values Press the Confirm key to accept and recording timer will start saving images at the selected interval 37 4 5 5 Delete Used for deleting the image When camera is in image replay mode press Menu key to activate the main menu select File gt Delete press Confirm key to pop out the below prompt box Press Confirm key to delete the current opened image If it has voice comment it will be deleted together Press C key to cancel the deletion CAUTION Before deleting make sure the file is not needed or already backed up Files cannot be recovered after deletion 4 5 6 Format Format is used for formatting the TF car
78. y defaults Press Menu key to activate the main menu Select Setup gt Default and press Confirm key to open the Reset dialog box Press Confirm key to reset the factory default Press C key to cancel the reset operation Appendix B indicates the detailed factory default parameter table NOTE Default Reset function will delete all parameters defined by user NOTE Restoring Default settings will NOT delete images stored on the TF card 32 4 5File 4 5 1 Open Press Menu key to activate the main menu Select File gt Open press Confirm key to open the saved images Press Left and Right keys to change the images Press C key to exit the opened image and return to measurement status The imager will open the last image displayed or the last image saved whichever occurred last 1 Current file name created by Imager 2 Current displayed image file number 3 Total number of images currently stored 33 4 5 2 Save It is used for saving the image performs the same functionality as the Save key Press Menu key to activate the main menu Select File gt Save press Confirm key to save the current image into the TF card or highlight Cancel and press Confirm key to cancel Save operation Alternatively the C key may be pressed to cancel Saving Data will display With Voice Save set in Save Settings menu if Voice Save was On Recording will start Speak clearly into the microphone on the control panel
79. ysis Report Software DL Reporter User s Manual DALI reserves the right to change this manual without prior notice 2005 DALI TECHNOLOGY Dali infrared analysis report software DL Reporter User manual Contents Ve INTOGUCTION sis se A TIA A ahaa dane RAM aaa asad ua oa e i 1 PSP Copyrights hc seis e E A santaa Ste 1 1 2 Erabili escent cise ediaeiten vest dante ANTIA MASI MATIN KITAAN 1 1 Bs Quality Assurances rect ssesec bret soc5 ane stack tod cee E A tauksmusuimikymsn 1 l 4 Compatibility vsscssccstesries IA AAA NN NA esas Ae et EB a as 2 LoS SYstefn requirements isamaa N NAS EINI S ES ATKINS Om N IT ns 2 1 5 1 Recommend hardware configuration uoosossssssss nenne 2 1 5 2 Operating System a a a a a a aseeseen 2 1 6 Software installation s ssssss ae se RAE VAARAN SANTRA Nain 2 lye Start the software nenn em amm aim ae Maids eee 5 2 Software interface sisinio eaa TT Ke ee sa KK e a ESE akka kea nsa eee akan 7 2 1 The main interface of Dali Thermal Images Analysis Report Software ussssen T 2 2 Men Darsa mmm AI EA A an A EA AA 8 22 WF MS meni Z eenia a a e e dna eimie 8 2 2 2 Edt MENU kA ereen eee u a eg oa TTS TAKES KATI iera iaae 9 DZ NIEN MONU a A E E cyeseurcecereunsteteastieaey 9 2 2 4 Drawing Menu z s i AIE soe a a a a io 9 2 2 9 WAINGOWS MENU onen sionou o ahtaalla Mea ehis 10 2 26 Help men n na e a RO 10 23 PO0lbar mmm A ET 10 2 951 Common Toolbar menene S
80. ysis report software DL Reporter User manual By selecting the file path to put in the file name you want press the save as button to save If the new file name is same as the one of the saved file name the system will remind you The extension of the report file is rpt 3 5 Save as templates The system is capable of save any report as a template the function of the template is to save the same or similar report contents When a new similar report is needed the corresponding template can be used On the base of the templates to create a new report will be more efficient The detail operate process is select file save as in submenu the standard file save as dialog box will popup By changing the file path or so to choose the saving path needed and input the file name press the save button to save If the new file name is same as the one of the saved file name the system will remind you The extension of the report file is rpt 3 6 Export the report as WORD file The system can convert the current operating pager into WORD file select the file gt export in current pager into WORD submenu the standard file save Windows dialog box will popup By changing the file path or so to choose the saving path needed and input the file name press the save button to save After the WORD file been converted system will automatically popup the enquire dialog Windows If yes is chosen th
81. zed 100 0 74 Iron Rusty 25 0 65 Oxidized 200 0 64 Cast iron Non Oxidized 100 0 21 Ouarry faced 25 0 94 Wrought iron Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless steel Oxidized 60 0 85 Steel Oxidized 200 0 79 Common brick Surface 20 0 93 Concrete Surface 20 0 92 Glass Polished plate 20 0 94 White 100 0 92 Lacguer Black 100 0 97 Smoke black 25 0 95 Carbon Candle soot 20 0 95 Rough lead surface 20 0 98 Oil paint Value of 16 colors 100 0 94 Paper White 20 0 93 Sand soil Surface 20 0 90 Timber Dressed 20 0 90 Water Distilled water 20 0 96 Skin Human 32 0 98 E Thin 21 0 90 Sii Thick 21 0 93 43 Appendix B Factory default parameter setting table Table 1 Measurement temperature setting table Value Parameter 03 LT7 Temperature Range 20 350 C 20 180 C Lens Standard Temp Unit C Ref Type Off Ref Temp 30 C Table 2 Measurement temperature correction table Parameter Value Emissivity 0 96 TCorrect 0 C TAmbient Temp Off Table 3 Analysis setting table Parameter Value Temp Alarm Off Alarming Temp 50 0 C Alarming Color None Isotherm Color Off Isotherm Temp 50 0 C Isotherm Width 1 0 C Table 4 System setting table Parameter Value Language English Brightness 60S Auto Calib 60 Video Mode Laser sight Quick Access NTSC StandbyTime 5 mins AutoOffTime 15 mins 44 DALI Thermal Images Anal