1. 10005 MAC Hebrew Default user account settings C Apply all settings to the current user account and to the default user profile So the information from the job which is in UTF8 will be translated in the local Windows code Page to build correctly the filename Example If the media source is called t in French and the filenameformatstring is defined as name XTAccess will name the file t mxf only if the Windows Local page is in French Limitations e Some wrappers can be written only in ASCII like the Avid OPAtom MXF and QT ref format e These character are not allowed by Windows and so will be replace by space lt gt O Fettweis File name Xsquare Suite ReleaseNote_v2 03 25 docx 10 mars 14 Page 19 of 20 Fees VU XSQUARE SUITE 2 03 25 RELEASE NOTE e tis necessary to have the same local code page on all the EVS computer Ascii Mode If you select ASCII as Filename Encoding Mode XTAccess will only use the 128 characters available in the ASCII format The ascii format is mainly based on the English Alphabet lf after processing of the job the file must contain character which are not present in the ASCII standard XTAccess will name the file UNICODE Example If the media source is called t and the FileNameFormatString is defined as name XTAccess will name the file UNICODE mxf O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 2
2. As Xsquare uses the same redundancy mechanism than IPD It is possible to install Xsquare on the same DB than the IPD DB But please first contact the EVS Support to check if the DB will be powerful enough lf Xsquare has to process more than 1 job every 2 seconds we strongly recommend using the new EVS DB hardware with more than 4 GB of memory DBS3 2D INTEL NETWORK BOARD DRIVER lf you are using a network board with the Intel chipset 82574 on your XTAccess Xsquare Hardware this is the default network board chipset on EVS XTAccess hardware we recommend upgrading the Intel driver to the version 18 1 or above O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 6 of 20 se VU XSQUARE SUITE 2 03 25 RELEASE NOTE LICENSES XSQUARE NO XSECURE LICENSE If you use Xsquare in standalone or to manage maximum 4 XT Access devices you will not need any Xsecure license or E Xsouare Kea ays AT AN al el KT ays XT Access XSECURE LICENSE If you use Xsquare to manage between 5 and 19 XTAccess devices you will need one Xsecure license Application 130 Xsquare module 10 Base Package ky XT Access af XT Access e AT Access fT If you use Xsquare to manage more than 19 XTAccess devices you will need one Xsecure license Application 130 Xsquare module 20 Unilimited Engines XTACCESS For XT Access Xsecure license is necessary if you want to t
3. Xsquare Suite 2 03 Release Note March 2014 1 0 s Monitoring EVS Servers Job Initiators Targets ScanXML instructions SOAP jobs XML jobs Configuration Orchestration Encoders Wrappers Icons Manager profiles Administration Users amp Access Groups Headquarters Headquarters Headquarters Available at 32 4 361 7000 1 973 575 7811 852 2914 2501 www evs com contact E VU XSQUARE SUITE 2 03 25 mmm RELEASE NOTE fc A Rech car E KE 3 EVS COMPLIANCE TD Ft E 3 GSOEIWAREINGTALTLATION 4 A GUARE ere 4 OPERATING SYSTEM COMPLIANCE lt ccc 0 ccccccescccsscseccssceencesceeeecetcaneseccestbescsdsdeacedseenscevanestssdeceheeseenceace ss 4 HARDWARE WHERE CAN I INSTALL XSQUARE 2 0 eeccccccccceeceeeeeeceeeeeeseeeeceeseeeceeseaaeeesseaeeeeseaeeeeeas 6 Bien 7 Py Ars KE 8 BUGSO FAMED EE 8 GENERAL XASGUARE LIMITA TIONG eriesrieiden rerin rrn naaa ain a NEEE E EREE 9 Ao OCA TON TOOLE E 9 XOQUARE SERVICE MONITORING tee ME 9 XSOQOUARE JOBS AND TEMPLATES geegent 9 XSQUARE tee ege Eege 10 XSQUARE SCANFOLDER saeco cesta ct enri se ae EEE EO EE ATERSE ESEE ESSEE AEE e Ea ae AE EEE 10 NEW FEATURES OF XTACCESS ZU see ENER RSR RER RER RER ENER 13 BUGS FIXED SINGE ATACCGESS recess ne pien si nema anien keke Nere K wm ARENE NARKS NENONEKRNE NERS 13 GENERAL XTACCESS LUIMITATIONS 14 OPERATING SYS TEM oassccesisenecscsnttesdentavadsantdtedenksseodecssdsadinndelesGeacedsadseddasndnes esas deedeesGegssstadsedeasersseeiteedandeec
4. Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE GENERAL XTACCESS LIMITATIONS OPERATING SYSTEM e tis necessary to set the UAC to the lower level to use XTAccess on Windows 7 e We requirement to deactivate the Areo mode on windows 7 and Server 2008 e XTAccess is not compatible with Windows Server 2003 64 bits NLE SETTINGS e General o Export PL TL EVS recommends opening the FCP EDL XML or Avid EDL AAF only when all the child backups are done Otherwise the NLE Apple FCP or Avid Media Composer will not update the growing media in their timelines o The EVS metadata present in the EDL exported from a PL TL are the metadata of the Original clip and not the metadata of the backuped file which could be different new Varld new duration new In point etc e Adobe NLE o The XMP metadata file doesn t support complex XML structure So some EVS metadata are not available in the XMP metadata file e FCPNLE o The delay between the EVS XT server Live and first picture available in FinalCutPro 7 is 15 seconds tests done in DVCPRO HD NTSC and IMX NTSC o XTAccess supports only FCP 7 with the version 5 of the FCP XML o FCP X is not supported o The Matrix of metadata for FCP is only working for the clips metadata not for the EDL e Avid NLE o XTAccess is not anymore compatible with Avid TM version before the version 2 5 o It is impossible to update a backup of train in Avid XDCAM OPATOM and Avid H264 proxy in thes
5. and later improved on Windows 7 It was reported that Apple SMB2 support was not fully compliant with the Microsoft implementation and we can reasonably expect Apple patches to solve this situation e Inthe meantime it s it strongly recommended to disable SMB2 on the client machine and force using SMB by running the following commands and then restarting Windows MISCELLANEOUS e Unicode amp ASCII extended Transfer of Unicode metadata to Avid Transfer Manager is not supported e Incase of backup of trains lt XT_Creation_Time gt tags are based on XTAccess workstation date and time not on XT date and time e It is not allowed to open edit or process a file stored in an XTAccess Scan folder XTAccess will not be able to access the file and could generate errors O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 16 of 20 Fees VU XSQUARE SUITE 2 03 25 RELEASE NOTE e Backup File Name Format String XTAccess is not able to handle special characters like the 2 sel in a string e Progress current TC in IPD is not available for the Copy XT to XT and with the Avid transfer The progress bar is available e In Hi Lo mode you need to use VCodec or GUID to do the difference between the two backuped clips and XML e K1 K2 etc take the XT keyword with maximum 12 characters and not the IPD Keyword with 64 characters e lf the backup rewrap fails because the target becomes unrea
6. Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 15 of 20 Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE e lf the backup paths are not exactly the same for example C Video Toto mxf is different than Xstore601 70 Video Toto mxf the XTAccess auto incrementation 1 2 3 etc of the filename is not working We recommend to use GUID in the file name format string in IPD to be sure that there will never be two times the same file created simultaneously by XTAccess e 31464 XTAccess doesn t create FCP XML file in case of backup of 3D clips e XTAccess doesn t reference OPAtom files in Avid Interplay in case of backup of 3D clips e 37057 TCINDATE and TCOUTDATE FileNameFormatString option don t work for the rewrap jobs RENDERING e Werecommend doing a maximum of two renderings of playlist in AVC Intra 100 at the same time otherwise memory overflow could happen e 86164 XTAccess can use a lot of memory to decode QT files due to the QT structure e 838861 XTAccess will not render the audio of one element SLSM All Frames in an EDL e 39025 The EDL rendering in DNxHD with a no video element as first element is not working MAC PRO OS 10 9 MAVERICKS e Issues were reported while transferring media to from Mac OS X Mavericks typically Encoder DLL Error This version of Mac OS X supports the SMBz2 file transfer protocol that was introduced by Microsoft in Windows Vista in 2006
7. The file must be refreshed by double clicking on the clip in Media Composer bin o Message PMM_INSUFFICIENT MEDIA in Media Composer when a media is updated and stretched the duration is longer than the original one It is not possible to increase the duration of a media sent to Avid Note reducing the duration of the media is OK see limitation below anyway o When updating the duration of the media in Interplay with a shorter duration the new short out is correctly updated but you need the delete the clip from the Media Composer bin and re import the media from Interplay in order to place the short out anchor in the right location in the viewer Limitation of Avid Media Composer o 85613 It is only possible to use the lt General_Infos gt and lt Clips_Infos gt XML tags in the Avid Tape TRANSCODING e XTAccess doesn t support job which starts with a bottom field In the job the TC In must always be a Top field e We recommend doing maximum two transcodings in AVC intra at the same time otherwise memory overflow could append Please contact EVS support to limit the Max Transcoding Job e 23834 it is necessary to configure the target resolution to 720P to do rendering of playlist in progressive mode e 35675 IMX 30 IMX 40 and IMX 50 are considered as different codec for XTAccess So the smartrendering is not working between these IMX Bitrates BACKUP e Growing clips without out point are not supported by XTAccess O
8. not be supported by the future Xsquare suite 3 x anymore e Windows 7 32 bits e Windows 7 64 bits default OS e Windows Server 2008 R2 SP1 64 bits O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 4 of 20 Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE Windows XP and Server 2003 will not be supported by the future Xsquare suite 3 x anymore For the 64 bit OS Xsquare will run as a 32 bits application The Framework NET 2 0 is mandatory to install Xsquare The framework NET 2 0 is not included in the Xsquare installer suite WINDOWS FIREWALL The installer will open these IP Ports on the Windows firewall On Xsquare device opened by Xsquare setup e 9001 NC observer e 9002 JobService e 9003 ConfigService e 9004 ProxyService 8998 Internal Xsquare ScanXML service e 8999 Internal Xsquare ScanFolder service 4 e 50000 TCP for the LinX connection management e 50100 to 50108 UDP for the LinX exchanges of commands On XTAccess device e 9000 For XTAccess opened by the XTAccess setup e 9005 XTA config opened by the XTAccess setup e 9010 Authentication service opened by the Xsquare setup e 48888 NotificationCenter opened by the NotificationCenter setup Note It is not possible to modify those port numbers BROADCAST ROUTING Your router must also support packet broadcast and multicast routing on these ports e 5353 for the Apple Bonjour Protocol e 50000 to 50002 for
9. the LinX Protocol e 50100 to 50108 for the LinX Protocol O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 5 of 20 Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE HARDWARE WHERE CAN I INSTALL XSQUARE The minimum system requirement for XTAccess and Xsquare is Workstation or server CPU Intel i5 2GB RAM 4GB Ram is recommended GigE board VGA 1024x768 At least 2GB free on the hard disk SQL 2005 or 2008 The hardware requirement CPU and Memory is directly linked to the number of XTAccess devices managed by Xsquare and the number of opened monitoring windows Please contact EVS support to design the hardware to be used for Xsquare based on your workflow XSQUARE SUITE STANDALONE XTAccess and Xsquare can run on the same computer but if XT Access performs transcoding jobs Xsquare may be slower than expected If Xsquare is used to manage more than 4 XTAccess devices Orchestrator we strongly recommend using a specific computer to run Xsquare The EVS App Server If you want to use Xsquare with redundancy system for the DB you will have to use the EVS DB 3U or 2U hardware the DB can be shared with IPD see below XSQUARE SUITE ON IPDIRECTOR HARDWARE OR IPDIRECTOR DB Xsquare XT Access and IPD 6 0 can be installed on the same computer with the PDirector In this case we recommend using XTAccess to process a maximum of 2 jobs without transcoding at the same time possibly with thumbnails
10. the ScanXML service there might be slight differences of behaviors between Xsquare and XT Access ScanXML For example if a required element is missing in a Job v1 or its value is incorrect XTAccess may use default value while Xsquare may reject the job If you plan to switch from XTAccess ScanXML to Xsquare ScanXML we strongly recommend testing your XML Job files to ensure the differences of behaviors are not blocking e The tag lt Job Src Eed Nb gt is not supported anymore e The lt Job Src_Field_TC gt value must represent a timecode less than 24 hours If it s not the case please use timecodes with dates Job_Src_Field_ DTC e XML jobs of grab are rejected if a template is associated to the scanXml Grab XML job must be used without template in Xsquare e tis recommended not to exceed 40 xml units in Xsquare We know that since Xsquare is used in conjuction with IPDirector there is a tendency to define one xml unit per IPDirector target instead of pointing several targets to the same xml unit While this might seem like good practice a high number of xml units will put a lot of stress on both Xsquare and PDirector If you really need to define more than 40 xml units please contact commonblocks evs com XSQUARE SCANFOLDER e The scan folder source must be a shared folder on the network UNC Path and the Scan Folder service must have Read Write access on it e f you want to be sure that the local XTAccess of the source watch fo
11. 5 docx Page 20 of 20
12. ailable for the EDL Clips job The EDL Clips job will always use compulsory true and keep partial false So if the EDL Clip job is canceled or fails XTAccess will delete all the files created The retry of the job is done with the information of the original job If the user changes the template used in the job the new template will not be used in the retry job except if Xsquare has rebooted between the original job and the retry O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 9 of 20 Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE XSQUARE SCAN XML e The Scan XML source must be a shared folder on the network UNC path and the Scan XML service must have Read Write access on it e No new features will be added in the XMLJobs v1 protocol The new features will only be available via Jobs v2 and or templates e Previously XTAccess allowed to use the same XML scan folder setting XML unit for the job to XT and to Files Now with Xsquare users will have to create two watch folders with two different templates or define no Xsquare template So the default XML unit of IPD must be correctly configured in Xsquare e Xsquare will not support anymore the old IPDirectorClipInfos tag in the EVS Metadata e It is impossible to access different UNC path from the same computer with different Windows User The Xsquare computer can access another computer with only one user e Due to the total new implementation of
13. chable i e network failure the incomplete a v file CANNOT be deleted O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 17 of 20 Fees VU XSQUARE SUITE 2 03 25 RELEASE NOTE INTERNATIONAL CHARACTER SUPPORT ICS EVS METADATA Xsquare manages all the EVS Metadata sources in UTF 8 The EVS metadata defined in the XML jobs and EVS XML metadata file must be encoded in UTF8 this is the case for the EVS client like IPDirector UTF8 is a variable width encoding that can represent every character in the Unicode character set included Chinese Russian etc So all the EVS metadata can be defined in different language apart from the EVS Umid which must be defined in ASCII These input data are then translated in different encoding format depends on the destination Here is a list of the main Xsquare X TAccess destinations and their supported encoding format Destination Encoding format AVID Interplay with the Webservices UTF 8 Avid AAF UTF 16 FCP XML UTF 8 Adobe XMP UTF 8 EVS XML and EDL UTF 8 e lf the destination uses the same encoding format that EVS there is not translation e If the destination uses a different encoding format XTAccess will translate the metadata in the destination format e The client application which read the destination must be able to display correctly the UTF 8 character e XTAccess supports only the common simplified Chinese character The extended Chinese character
14. e situations no problem with the others codecs wrappers If the initial duration was lt 2h and the update gt 2h If the initial duration was gt 2h and the update gt that the initial duration o It is impossible to define the filename for the Avid XDCAM OPATOM and Avid H264 proxy files The filename will be automatically an Avid GUID o XTAccess uses the Avid AMT SDK to write H264 and XDCAM OPATOM files There are two Avid windows registry keys which can be modified to improve the writing performance By default XTAccess initializes theses registry keys with these values but it is possible to modify them depends on the topology project O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 14 of 20 Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE On windows 64 bits HKEY LOCAL_MACHINE SOFTWARE Wow6432Node Avid Technology GenericHelper MXF e BufferSize 524288 e ReadBufferSize 16777216 On windows 32 bits HKEY LOCAL _MACHINE SOFTWARE Avid Technology GenericHelper MXF e BufferSize 524288 e ReadBufferSize 16777216 Valid values are 512 kB 1 MB 2 MB 4 MB 8 MB or 16 MB o The delay between the EVS XT server Live and first picture available in MediaComposer is 20 seconds for the video and 30 seconds for the audio tests done in DVCPRO HD NTSC and IMX NTSC o When browsing a growing EWC media sometimes Media Composer displays FILE OTHER instead of the video
15. easeNote_v2 03 25 docx Page 11 of 20 Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE Make sure the Windows service is well configured In services msc the service SQL Server SQLEXPRESS or SQL Server MSSQLSERVER or other instance name should have Startup Type Automatic and be Started Sometimes SQL Server Management studio is not installed This is not required but it is very useful for debug management TODO add links to SQL Server Management studio installer 32 64 and 2005 2008R2 SQL Server is not listening on network interfaces o Open Start Menu Programs Microsoft SQL Server 2008 R2 SQL Server Configuration Manager o Open SQL Server Network Configuration gt Protocols for SQLEXPRESS or other instance name gt TCP IP Make sure Enabled has Yes Listen All has Yes o In IP Addresses make sure all required IPs have Active Yes Enabled Yes and IP Adress is right sometimes it is wrong o You have to restart the service SQL Server SQLEXPRESS or similar Make sure Mixed mode is activated Windows sa evs authentication If you have SQL Server Management Studio go to instance properties gt Security gt SQL Server and Windows Authentication mode then restart SQL Server service From http www mssaltips com salservertip 144 1 correct the sql server authentication mode in the windows registry Make sure sa account is activated Note Xsquare NC and Authentication installers may do this step for you if they can co
16. es 14 DO Ses ed OB BL E 14 TRANSCODING EE 15 BAr O gamer enone we een en ee ee eee eee ee 15 Be ah Beha E 16 MAC PRO OS 10OIMAVERICKE 16 POS Re RE 16 INTERNATIONAL CHARACTER SUPPORT IC 18 EVO dE RN TA EE 18 SIB see acres pense E E E EA E E seen sncuie obec eneosaseereyeee 18 O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 2 of 20 Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE LIST OF DOCUMENTS Release notes e Xsquare_ReleaseNote_v2 03 25 pdf Release note of Xsquare Suite 2 03 e XTAccess_ Codecs_2 03 pdf List of codecs amp wrappers compatible with XTAccess for wrapping decoding and encoding UserMan e Xsquare_InstallMan_v2 03 pdf document which explains how install Xsquare e Xsquare_Userman_v2 03 pdf user manual for Xsquare Actually this the PDF format of the Xsquare 2 03 online help available directly in the Xsquare interface TechDoc e How to migrate from XTAccess to Xsquare pdf document which explains how to migrate from XTAccess to Xsquare This document is only available on request Please contact support evs com for more information e Xsquare Automatic redundancy system pdf document which explains how to create a redundancy system with Xsquare This document is only available on request Please contact support evs com for more information e How to create an Adobe Target docx document which explains how to create an adobe target with IPD e Xsquare API documentatio
17. lder will execute the job you will have to create a Removable cluster e It is impossible to access different UNC path from the same computer with different Windows User The Xsquare computer can access another computer with only one user e The move job if the scanfolder job is failed will not work if the source file is still growing XTACCESS CONFIGURATION THOUGH XSQUARE O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 10 of 20 Fees VU XSQUARE SUITE 2 03 25 RELEASE NOTE e XTGateway will be configured by default to be able to do 4 operations of playlist rendering at the same time It will be impossible to change this configuration from Xsquare The modification of the XTGateway configuration must be done manually on each XTGateway in the configuration window e The user will still have to install and configure manually the EVS AVID Tools for the integration with the Avid Transfer Manager Xsquare will not manage the AVID TMclient ini file e The following parameters will not be available in the Xsquare configuration interface So if necessary these parameters will have to be configured manually on each XTAccess registry keys Max Log size In MB Default 2 IP Retry Default 12 IP Retry timeout Default 5000 Enable Retry Default 1 MinFieldsToWriteBeforeReflnCEDB Default 1000 GENERAL LIMITATION AND INSTALLATION e Xsquare could take up to 5 minutes to detect a new EVS server o
18. n this document is only available on request Please contact commonblocks evs com for more information There is no XTAccess release note The XTAccess release note is included inside this release note EVS COMPLIANCE MATRIX e Multicam 12 02 and Multicam 11 02 e IPD 6 41 Please contact commonbiocks evs com for more information O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 3 of 20 se VU XSQUARE SUITE 2 03 25 RELEASE NOTE SOFTWARE INSTALLATION See Installation Manual for details of the installation procedure XSQUARE SUITE Xsquare is distributed within a complete package called Xsquare Suite Xsquare Suite consists of Xsquare itself plus a family of EVS applications as well as prerequisite Third parties software We strongly recommend using this package of software and keeping the version united with the package EVS software included in the Xsquare Suite Version Authentication Service 2 3 3 new version since the 2 2 release Maintenance Plans 1 6 0 Other software included in the Version Xsquare suite VC Redist 10 0 40219 OPERATING SYSTEM COMPLIANCE Xsquare is compatible with e Windows XP not recommended This OS will not be supported by the future Xsquare suite 3 x anymore e Windows 2003 Server 32 bits not recommended This OS will not be supported by the future Xsquare suite 3 x anymore e Windows 2003 Server 64 bits not recommended and this OS will
19. n the network So we recommend forcing manually Xsquare to discover the EVS servers after each modification example EVS Server reboot on the setup Force discover Last discover 16 05 2013 14 18 44 Discovered servers 0 e With SQL Express 2005 The Xsquare DB is limited to 4GB It is not the case on SQL Server e The Xsquare installation could take time 20 minutes and ask for reboot if SQL express and the NET frameworks are not already installed on the computer e The SQL Express installer could ask to close the Xsquare suite setup In this case you can ignore the error and continue the installation e If you create several XTAccess with the same ghost it is necessary to remove this registry key HKEY CURRENT USER Software EVS Broadcast Equipment XTAccess XTAccessUUID in the original ghost This Key is created automatically at the first boot of XTAccess and must be unique e The web interface is compatible with all Internet browsers compatibles with Silverlight except Google chrome on Apple OS e tis not possible to downgrade Xsquare The upgrade is supported but not the downgrade If you want to downgrade you will have to delete completely the Xsquare DB SQL SERVER When SQL Server is already installed before Xsquare Suite install it is possible that it is not well configured especially when it comes from Visual Studio in dev machines Some steps may or may not be required O Fettweis 10 mars 14 File name Xsquare Suite Rel
20. nnect using Windows Authentication o Open SQL Server Management Studio connect SQL instance using Windows Authentication Open lt instance gt gt Security gt Logins gt sa gt Properties Set evs in password and confirm password In Status make sure Permission is Grant and Login is Enabled After pressing OK you have to restart SQL Server service O O O ZE O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 12 of 20 E VU XSQUARE SUITE 2 03 25 RELEASE NOTE NEW FEATURES OF XTACCESS 2 03 LZ XTAccess v2 3 6 22 MONITORING MODE SN 25570 Reporting Connected belgmofe NickName BELGMOFEr Group DefaultGroup Win 6 1 AdminMode Kl sins Status FrameRate ByteRate Sta Connected to Xsquare BELGMOFE Connected to Bonjour e Support of M11 02 and M12 02 XTAccess 2 3 has been completely validated with Multicam 11 02 and 12 02 e Support of the Multicam swap mix effects e New encoder profile MXF OP1a XDCAM HD 24 bits 16 audios this profile allows you to create XDCAM file with 16 audios Destination Icon BUGS FIXED SINCE XTACCESS 2 02 e XTA 710 Failed to convert ProRes to Mpeg1 e XTA 639 Special caracters not supported anymore in TapelD e XTA 517 Backup clip to wav gt XT_Nb_ Videos 1 instead of 0 e XTA 590 PLR with train elements failing O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 13 of 20
21. ranscode your source files or clips Xsecure license is also necessary for the rendering of EDL playlist or timeline O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 7 of 20 se VU XSQUARE SUITE 2 03 25 RELEASE NOTE NEW FEATURES e Support of M11 02 and M12 02 Xsquare 2 3 has been completely validated with Multicam 11 02 and 12 02 e New encoder profile MXF OP1a XDCAM HD 24 bits 16 audios this profile allows you to create XDCAM file with 16 audios Destination Icon Encoder Wrapper profile MAF OFia XDCAM HD 24 bits 16 audios BUGS FIXED e XSQ 410 The role name is limited to 25 caracteres e XSQ 402 Xsquare Suite install Silverlight 64bits in loop on Windows Server 2003 64 bits e XSQ 379 Memory leak when reloading jobs from database to cache e XSQ 451 Jobs stay scheduled in Xsquare despite of available job processors O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 8 of 20 Fa VU XSQUARE SUITE 2 03 25 RELEASE NOTE GENERAL XSQUARE LIMITATIONS ASSOCIATION TOOL To be able to associate XT Access to Xsquare they must be on the same VLAN If Xsquare and XTAccess are on different VLAN the Broadcast packets must be routed by the switch between the VLANs XTAccess and Xsquare hostname must follow the DNS naming convention and contain only the ASCII letters a through z in a case insensitive manner the digits 0 through 9 and the h
22. s could not be supported Anyway extended Chinese character are not common and used in the computer world FILENAME READ XTAccess can read as source file in a job or as source file in a scanfolder all the files which are encoded in the local code page of Windows O Fettweis 10 mars 14 File name Xsquare Suite ReleaseNote_v2 03 25 docx Page 18 of 20 RELEASE NOTE Fe VU XSQUARE SUITE 2 03 25 pe WRITE XTAccess can write files with filename in ASCII or in the same language than the local windows codepage This option is available inside the Xsquare Configuration Pstration Group EDL Sub Jobs File Reader NoBuffering File Writer NoBuffering Filename Encoding Mode QT Ref ltGroup Auto Local ltGroup Auto ASCII Local Mode default value If you select Local as Filename Encoding Mode XTAccess will only use the characters available in the local Windows code page Regional and Language Options Regional Options Languages Advanced Language for non Unicode programs This system setting enables non Unicode programs to display menus and dialogs in their native language It does not affect Unicode programs but it does apply to all users of this computer Select a language to match the language version of the non Unicode programs you want to use Code page conversion tables 10001 MAC Japanese 10002 MAC Traditional Chinese Bop 10003 MAC Korean 10004 MAC Arabic
23. yphen The Apple Bonjour protocol used to discover the XTAccess and Xsquare must be started before Xsquare and XT Access XSQUARE SERVICE MONITORING TOOL On Windows 7 64 bits to be able to use the Xsquare Monitoring tool and restart services it could be necessary to modify these parameters Run gt gpedit msc gt Computer Configuration gt Windows settings gt Security settings gt Local Policies gt Security Options o User Account Control Behavior of the elevation prompt for administrators in Admin Approval Mode Prompt for credentials gt Elevate without prompting o User Account Control Run all administrators in Admin Approval Mode Enable gt Disable o User Account Control Switch to the secure desktop when prompting for elevation Enable gt Disable XSQUARE JOBS AND TEMPLATES The multi destinations are available for all the jobs except for the Avid Transfer Engine jobs It is impossible to create jobs to Avid Transfer Engine with more than one destination lt is impossible to create more than one NLE referencing per destination It is possible to reference up to two destinations to Xedio The EVS Server MTPC network board must be connected to the Network to use the auto codec detection mechanism To use the auto codec detection it is necessary to have XTAccess Xsecure licenses The auto codec detection will be run every 30 seconds on the network The compulsory and keep partial parameters are not av