        Meterhub Installation Manual
         Contents
1.    be Link Out Link In Lii                TriStar  Figure 5  Multiple Meter Hub Network    For large systems  multiple Meter Hubs can be connected via the  Link In   Link Out ports A  amp  B to expand the number of available ports   Figure 5 above shows network connections for a system with nine  TriStars and two meters  Up to four Meter Hubs can be linked together   accommodating up to 15 MeterBus devices  Each device in the network  must be programmed with a unique MeterBus ID     16 Morningstar Corporation       4 0 Operation    After the Meter Hub has been mounted and wired into the network  there  are few operator tasks to perform  This section provides information  pertaining to the normal operation and maintenance of the Meter Hub     4 1 Status LEDs    Five Status LEDs indicate proper network connection to each port  The  Status LED on Port B indicates power status for the Meter Hub  The  Meter Hub must be powered through Port B for correct operation     Status LED ON  Green      The port is powered with a correct network connection     Status LED OFF      No devices are connected to the port      Adevice that supplies power is not connected to the port  see    table 1 on page 11      There is a wiring error or broken network cable    NOTE   KS Devices listed in column Y of table 1 cannot be the only devices connected to ports 1 4   or port B     Meter Hub Operator   s Manual 17    4 2 Maintenance   The Meter Hub is designed to run automatically without the need for u
2. 2 or MSView PC software     Y See individual product documentation for details about networking     Y Firmware updates for all products are available on our website     http   www morningstarcorp com    Meter Hub Operator s Manual    3 2 Example Networks    Example Network  1  Typical Small Network               TriStar Meter              lt  gt  AV                            FT m       TriStar       Figure 3  Small Network Diagram    A simple two TriStar system with meter is shown in figure 3 above  The  TriStar on Port 1 is electrically isolated from the TriStar on Port B and  meter on Port A  Differences in ground potential  disconnected grounds   and differing system voltage will not damage the network equipment or  controllers     14 Morningstar Corporation    Example Network  2  Typical Medium sized Network                            TriStar      lt  gt  AV  Meter  jo           o                  E          No  Ale  we  Be    6                  f Relay TriStar  TriStar Driver With  ees Meter                   Figure 4  Medium sized Network    The Medium sized network shown in figure 4 includes three TriStars   one Relay Driver  and two meters  There can be a maximum of two  meters on the MeterBus network  The Relay Driver requires power from  the MeterBus  Since ports 1 through 4 on the Meter Hub do not provide  output power  a TriStar powers the Relay Driver before connection to  Port 1     Meter Hub Operator   s Manual 15    Example Network  3  Large MeterBus Network 
3. METER                    Model  HUB 1          MORNINGSTAR    orporation    8 Pheasant Run  Newtown  PA 18940 USA  email  info morningstarcorp com  www morningstarcorp com    Dimensions in millimeters  inches         No    AVISONINSO    93 108   36511 427            uojjeJiunwwo3 sngiajeyy       Table of Contents    1 0 Getting Started       1 1 What s in the Box  5  1 2 Features 6  2 0 Mounting   2 1 Required Tools 7  2 2 Wall Mounting 8  2 3 DIN Rail Mounting 9  3 0 Network Connections   3 1 Networking Rules 12  3 2 Example Networks 14  4 0 Operation   4 1 Status LEDs 17  4 2 Maintenance 18    5 0 Troubleshooting  6 0 Warranty  7 0 Technical Specifications    Save These Instructions  This manual contains important safety  installation and operating  instructions for the Meter Hub     The following symbols are used throughout this manual to indicate  potentially dangerous conditions or mark important safety instructions     WARNING  Indicates a potentially  dangerous condition  Use extreme  caution when performing this task   CAUTION  Indicates a critical  procedure for safe and proper  operation    NOTE  Indicates a procedure or  function that is important for safe and  proper operation      gt     General Safety Information    Read all of the instructions and cautions in the manual before  beginning installation       There are no user serviceable parts inside the Meter Hub  Do not  disassemble or attempt to repair the controller       There are no fuses or disconnects ins
4. TI    Table 1  Morningstar Device MeterBus Power Specifications          Meter Hub Operator   s Manual 11    3 1 Networking Rules    Hardware    Y Amaximum of 15 devices are allowed on a single MeterBus net   Work     Y ATriStar meter is required for MeterBus network information dis   play  A maximum of two meters are allowed on a MeterBus network   Use one of the following models     TriStar Digital Meter 2 TS M 2  TriStar Remote Meter 2 TS RM 2    Table 2  TriStar meters compatible with MeterBus networks       Y Ports 1   4 on the Meter Hub are each isolated from all other ports   There is no power output on these ports     Y Ports A  amp  B are not isolated from each other     v One device from column X of table 1 must be connected to In   put Power Port B to power the Meter Hub  When linking multiple  Meter Hubs  Power Out Port A is connected to  nput Power Port B  of the following hub   see Example Network   3  pg  15     v Only one device from column X of table 1 can be connected to each  port on the Meter Hub     Y Devices listed in column Y of table 1 require MeterBus power  For  this reason  devices in this column cannot be the only device con   nected to ports 1 4     12 Morningstar Corporation    Y Multiple Meter Hubs can be connected using the Link Out Link In  ports A amp B     Software and Firmware    v All devices on a MeterBus network must be programmed with a  unique MeterBus address  The MeterBus address of each device  can be modified using a TriStar Meter 
5. at the mounting  screws will not penetrate wires or other objects located on the opposite  side of the surface     Step 3   Hold the Meter Hub in place and use a pencil or pen to mark the surface  at the location of each of the four mounting holes  Remove the Meter  Hub and drill 3 mm  1 8     pilot holes at each mark     Step 4   Place the Meter Hub onto the surface and align the mounting feet  holes with the four pilot holes  Use  10 screws  included  to secure the  Meter Hub to the surface     8 Morningstar Corporation    2 3 DIN Rail Mounting    The Meter Hub mounts to standard 35 mm  1 3 8     DIN rail                       Figure 2  Mounting the Meter Hub on DIN rail     Step 1   The DIN rail location should be protected from direct sun  high  temperatures  corrosive fumes  and water  Do not install in a confined  area where battery gasses can accumulate     Step 2   Place the Meter Hub over the DIN rail in the location where it is to be  mounted  Make sure there is sufficient room above and below the Meter  Hub for wire connections     Step 3  The Meter Hub was designed for installation onto a DIN rail without the    Meter Hub Operator   s Manual 9    need for tools  On the bottom of the Meter Hub  there are three hooks  that catch the upper lip of the DIN rail and one wide tab that snaps over  the bottom lip of the DIN rail  Hold the Meter Hub at an angle and gently  slide the three upper hooks on the back of the Meter Hub over the upper  lip of the DIN rail as shown 
6. ensions    Weight   Port Connections  Enclosure  Compatible DIN rail    Environmental  Operating Temperature  Storage Temperature  Humidity  Tropicalization    Certifications  CE  RoHS       500 Volts  8 mA    135x108x37 mm  5 3x4 3x1 5 in   0 19 kg   0 41 Ibs  RJ 11  gold plated  Type 1  indoor rated  35 mm standard     40C to  60C    55C to  85C   100    NC    conformal coating on both  sides of printed circuit board    Specifications subject to change without notice   Designed in the U S A    Assembled in China    MS ZMAN HUB 01 B 07 09    Meter Hub Operator s Manual 21    
7. ide the Meter Hub       Do not allow water to enter the product     4 Morningstar Corporation    1 0 Getting Started    1 1 What   s in the Box   Y Meter Hub       v Operator s Manual  Y Five MeterBus    RJ 11 Cables  1 meter  3 ft  in length    v Four Mounting Screws            Meter Hub Operator   s Manual    1 2 Features                 qn                          sng4ejoyy        WVIS6RINSON         Figure 1  Features of the Meter Hub    1  Port Status LEDs  Indicates network connection status for each port    2  Input Power Port B  Link In   Input power for the Meter Hub  provided by a device    3  Output Power Port A  Link Out   Power output for meters or linking Meter Hubs    4  Mounting Feet  For wall mounting the Meter Hub    5   Ports 1   4  Isolated network ports    6  DIN Rail Release Tab  Snap on  Release from DIN rail    6 Morningstar Corporation    2 1 Required Tools       Y Philips screw driver  Y Wire strippers   v Wire clippers   Y If wall mounting   Drill    v  f wall mounting   3 mm  1 8     drill bit         Meter Hub Operator   s Manual    2 2 Wall Mounting    Step 1   Locate a suitable mounting surface that is protected from direct sun  high  temperatures  corrosive fumes  and water  Do not install in a confined  area where battery gasses can accumulate     Step 2   Place the Meter Hub on the surface where it will be mounted and  determine where the cables will enter exit  Be sure there is sufficient  bending room for the communication cables  Verify th
8. in figure 2  action  1      Step 4   Once the hooks have engaged the upper lip of the DIN rail  rotate the  Meter Hub so that it is flush and parallel to the DIN rail as shown in figure  2  action  2      Step 5   Hold the Meter Hub firmly in position while pushing the DIN rail tab  upwards as shown in figure 2  action  3   The tab will firmly snap when  properly engaged with the DIN rail     CAUTION  Equipment Damage  Never attempt to remove the Meter Hub from the DIN rail without first releasing the DIN  rail tab  Damage to the Meter Hub will result     10 Morningstar Corporation    3 0 Network Connections    The Meter Hub allows multiple Morningstar devices to communi   cate on a MeterBus network  Networked controllers can share data  and display net system information on a TriStar Meter 2  Table 1  below lists all Morningstar Devices that can be networked using  the Meter Hub  Table 1 is divided into two columns  The first col   umn lists devices that supply power to the MeterBus Network  All  devices listed in the second column require power from the Meter   Bus Network to operate  It is important to understand the power  requirements of each device connected to a MeterBus network   The Meter Hub electrically isolates devices that supply power to  the MeterBus  preventing grounding problems  Devices that re   quire power from the network must be connected to devices that  supply power     X   Y   Supplies Power Requires Power      P  TriStarMPPT 45 oo O  TriStar MPPT 60 
9. orningstar  distributor with shipping charges prepaid  Provide proof of date and place of purchase  To  obtain service under this warranty  the returned products must include the model  serial  number and detailed reason for the failure  This information is critical to a rapid disposition  of your warranty claim  Morningstar will pay the return shipping charges if the repairs are  covered by the warranty     WARRANTY EXCLUSIONS AND LIMITATIONS  This warranty does not apply under the following conditions       Damage by accident  negligence  abuse or improper use      Unauthorized product modification or attempted repair       Damage occurring during shipment    THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE   EXCLUSIVE AND IN LIEU OF ALL OTHERS  EXPRESS OR IMPLIED  MORNINGSTAR  SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES  INCLUDING   WITHOUT LIMITATION  WARRANTIES OF MERCHANTABILITY AND FITNESS FORA  PARTICULAR PURPOSE  No Morningstar distributor  agent or employee is authorized to  make any modification or extension to this warranty     MORNINGSTAR IS NOT RESPONSIBLE FOR INCIDENTAL OR  CONSEQUENTIAL DAMAGES OF ANY KIND  INCLUDING BUT  NOT LIMITED TO LOST PROFITS  DOWNTIME  GOODWILL OR    DAMAGE TO EQUIPMENT OR PROPERTY     8 Pheasant Run  Newtown PA 18940  Email  info morningstarcorp com    www morningstarcorp com    20 Morningstar Corporation    7 0 Technical Specifications    Electrical  Minimum Isolation  Ports 1 4   Self consumption  per port     Mechanical  Dim
10. ser  intervention  However  the operator should perform the following tasks  annually to ensure continued operation     v Verify that the Status LEDs indicate normal operation        Check all network connections for corrosion or loose connections     v Inspect the case for nesting insects    18 Morningstar Corporation    5 0 Troubleshooting    Problem   A device is connected to a Meter Hub port  but the Status LED for the  port is not ON        v Verify that the connected device is listed in column X of table 1 on  page 11  Adevice from column X is required to power the port     Y Try a different network cable    v Make sure the device itself has power    Y Connect the device to a different Meter Hub port   Problem     The Status LED is ON for each connected port but there is no  communication     Y Check Port B power  A device must be connected to Port B to  power the Meter Hub circuits     v Verify that each device has been programmed with a unique ID     v Try different network cable s      Meter Hub Operator s Manual 19       6 0 Warranty    The Meter Hub is warranted to be free from defects in material and workmanship for a  period of FIVE  5  years from the date of shipment to the original end user  Morningstar will   at its option  repair or replace any such defective products     CLAIM PROCEDURE   Before requesting warranty service  check the Operator   s Manual to be certain that there  is a fault with the Meter Hub  Return the defective product to your authorized M
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Sony VCA-130 User's Manual  香りコイン SUC-P860  Version 1  安全にお使いいただくため縄  RCA RC65I Headphones User Manual  Plantas Eléctricas Solares Luminasol®  Mémoire de maîtrise - École Polytechnique de Montréal  Massageador Max Hammer Modelo: RM  印刷用PDFはこちら(PDF:255KB)  Manual del usuario - Honeywell Analytics    Copyright © All rights reserved. 