1. what parts and order of the patient s name to print on the label NOTE The name in the study must be formatted according to the DICOM standard Q O CODONICS The file fields default txt in the labels folder on the SmartDrive controls what information will be printed for each field in a study reference Virtua User s Manuals To configure the format of the patient name printed on the label add or modify the fieldFormat section and the parameter patientName Parameter patientName Settings any combination of spaces punctuation and the following tags The brackets and letters must be typed exactly into the fields default txt file See example below e lt FirstName gt or lt Firstinitial gt e lt LastName gt or lt Lastinitial gt lt MiddleName gt or lt Middlelnitial gt e lt Prefix gt lt Suffix gt Default Blank with the implicit format lt LastName gt lt FirstName gt Description Specifies what parts of a patient s name or initials to display on the label as well as the order they are displayed and any desired punctuation In the example fields default txt file below some parameters left out for brevity the patient name on the label will be printed as SMITH DR J T JR Example profile fields default txt 3FieldStudies patientName 1 4FieldStudies patientName 1 fieldFormat patientName lt LastName gt lt Prefix gt lt Firstinitial gt lt Middlelnitial
2. 01 171 002 Disc Encryption Codonics Part No 901 203 002 Configuration to automatically run the viewer on discs with one viewer and no reports If selected when resulting discs are launched a message will show for five seconds before automatically initiating the viewer application Clicking on the message will immediately launch the viewer The following parameter was added to the Job Profile Parameter useLaunchpadOnAllDiscs Settings true or false Default true Description For discs with only one viewer and no reports or attachments setting this to true will make the disc always run the LaunchPad application e false will make the disc launch a brief message and then run the viewer For all other discs the LaunchPad will be displayed regardless of this setting Clarity 3D Fusion Viewers and Clarity version 6 1 SP10 Viewers included This revision addresses MRI slice location information that may be displayed incorrectly refer to Virtua Product Bulletin No 205 Codonics Part No 903 208 001 These viewers have also been released independently on the Virtua Accessories and Manuals Disc Version 3 2 0 LogMelIn Rescue remote connection capability is now integrated with the Virtua interface This capability will provide better technical support for diagnosing issues at many sites Q O CODONICS Windows XPE security patch updates thru January 2010 Polish amp Hungarian GUI Languages added Abil
3. 4 001 02 numbers for the site details The Ink Saver label displays more characters Cannot set date and time from Virtua user interface in some Tier 2 locales The workaround for this problem is to run the system in the en_US locale which is the factory setting set the local time and date correctly and then change the system to the desired operating locale A list of Tier 2 locales and instructions for changing the locale are in the Virtua User s Manual Technical Support If problems occur during software installation contact Codonics Technical Support between the hours of 8 30AM and 5 30PM EST weekends and U S holidays excluded Phone 440 243 1198 Email support codonics com Website www codonics com CODONICS We bring the future into focus 17991 Englewood Drive Codonics Limited KK Middleburg Heights OH 44130 USA New Shibaura Bldg F1 440 243 1198 1 3 11 Shibaura 440 243 1334 Fax Email info codonics com www codonics com Phone 81 3 5730 2297 Fax 81 3 5730 2295 Minato ku Tokyo 105 0023 JAPAN
4. Codonics Virtua Operating Software Version 3 2 0 Release Notes Summary Version 3 2 0 software provides product improvements for the Codonics Virtua Medical Disc Publisher CAUTION Version 3 2 0 software is intended for use on all Virtua systems except for the Virtua 1 model Version 3 2 0 software will not install on the Virtua 1 model controller serial numbers beginning with 70C This document details the changes from Version 3 1 2 software Virtua User s Manuals provide further information on the use of Virtua systems If you are upgrading from an older software version previous Virtua Release Notes can be downloaded from the Codonics web site NOTE After installing software to ensure proper function of the interface please restart any remote browsers viewing the Virtua interface New Features Attaching Non DICOM Objects Virtua allows a user to associate patient reports in a non DICOM document format and other documents such as movies or images with a DICOM study by uploading them through a web interface and then recording them to the patient s disc For more information see the Attach Non DICOM Objects Technical Brief Codonics Part No 901 227 001 Custom LaunchPad Image The image displayed on the LaunchPad application on a disc can be changed to a custom image To configure a custom image 1 Remove the Virtua SmartDrive or access it over the network 2 Place the image for example am_m
5. amily systems When media Smart Detect mode is enabled leave the Recorder cover open when installing software Closing the cover with Smart Detect mode enabled will cause Virtua ECO to load another disc on top of the installation disc The LaunchPad does not work on Windows NT Windows 98 or Windows 2000 OS with Internet Explorer version lower than 5 5 When discs created on Virtua are installed on PCs the LaunchPad is initiated The LaunchPad can be used on Windows 2000 XP Vista and Windows ME with Internet Explorer v5 5 or higher Users of affected platforms can use Windows Explorer to navigate to and launch viewers or open reports Changes to the HIPAA log during software changes Since the extension to the HIPAA log file log job is changing from txt to csv in this software version entries made after an upgrade will only occur in the csv file Therefore refer to the csv file for those entries if a subsequent downgrade occurs Following entries will then go back to the ixt file Virtua ECO family system CD and DVD status lights unexpectedly alternate green and off for longer than two minutes In some circumstances Virtua ECO may show an unexpected shutdown taking longer than two minutes The workaround is to perform a hard shutdown press the System power button for about five seconds Power on the system to return to normal operations when desired IP address conflict is not reported If Virtua is configured to support a r
6. ange of IP addresses and there is a conflict Virtua will not notify the user Successfully archived studies not marked as archived Aborting a Scheduled Archive while a label is being printed may not mark studies successfully archived as archived Studies will be re archived during the next Scheduled Archive session S O CODONICS Unable to anonymize large DICOM image files gt 256 MB The system can become unresponsive and will then need to be rebooted Receiving a study while a previously sent version is recording can cause the recording job to fail or produce an unusable disc Known Issues for International Regions No Unicode support in Viewer The Clarity Medical Image Viewer does not correctly display Unicode characters It is uncommon for DICOM files to be encoded in Unicode Limited Viewer support for international characters Refer to the Clarity Viewer Manual Codonics Part No CLARITY MNLU for details No support for Indian locales The Tamil India ta_IN locale does not correctly support Tamil characters Site phone numbers with country codes may be truncated on labels Most labels support nine characters for phone Get it all with just one call 1 800 444 1198 All registered and unregistered trademarks are the property of their respective owners Specifications subject to change without notice Patent 7 375 737 and others pending Copyright 2010 Codonics Inc Printed in the U S A Part No 901 23
7. dure are strongly recommended Compatibility problems with Internet Explorer 7 and Firefox 3 There are minor cosmetic problems when remotely connecting with both browsers Internet Explorer 6 is recommended for remote connections to Virtua Discs required counts are inaccurate for multi disc backup jobs When multi disc backup jobs all studies included in the job will not fit on one disc are queued the Discs Required count in the Status Details tab and the X of Y discs recorded count on the Discs tab might contain inaccurate counts Typically the count will not increment until the entire set is completed Known Uncommon Issues This section details uncommon or obscure issues with 3 2 0 software that are unlikely to be experienced by most users DICOM association limit may be exceeded DICOM clients that open many simultaneous associations might exceed Virtua s limit of 24 simultaneous connections This can cause the system to stop receiving DICOM jobs requiring the system to be rebooted Time remaining indicators for jobs are inaccurate if there is more than one Jobs page If there is more than one page of jobs queued eight or more jobs the time remaining indicator on the Discs tab will not be accurate on any pages other than the first page Each page starts the time estimation over again without accounting for the jobs on the previous page Special handling for Recorder cover when installing software on the Virtua ECO f
8. edcenter png in the profiles site folder on the SmartDrive 3 Edit the sitelmage parameter in the Site profile for example site default txt and set its value to the name of the desired image for example sitelmage am_medcenter png Discs recorded using this site profile will now display the custom image in the LaunchPad Release Notes Buena Vista Imaging cT MRI d ae BVI Ze Parameter sitelmage Settings Image_Filename Default None Description Specifies an image file located in the profiles site folder on the SmartDrive to use as a custom image in the LaunchPad Parameter sitelmageSettings Settings Widthx Height for example 420x360 Default Blank Description Usually does not need to be set unless the image does not look as expected Specifies a width and height to use when centering an image or Flash movie in the space provided in the LaunchPad NOTE LaunchPad can display a maximum image size of 700x550 Smaller images will automatically be centered Supported image file formats include JPEG PNG GIF and SWF Flash Movie It is recommended to create a trial disc to verify proper results Record by Series Virtua allows a user to manually record a subset of the Series in a DICOM Study For more information see the Record by Series Technical Brief Codonics Part No 901 226 001 Product Improvements Flexible display of patient name on disc label This feature allows users to configure
9. gt lt Suffix gt NOTE Not all facilities and equipment populate full patient name information including prefixes and suffixes If the data from the facility does not contain this information it cannot be displayed on the disc label File content sent using the Virtua Direct to Disc D2D feature can now be encrypted Encryption of D2D jobs can be configured via the Job Profile specified by the Hot Folder profile Alternatively encryption of D2D jobs can be specified via a D2D Control file For details see the Disc Encryption Technical Brief Codonics Part No 901 203 002 Any DICOM tag can now be printed on the disc label created using the Direct to Disc feature If the D2D job contains a DICOMDIR file at the root of the disc contents and this file correctly identifies DICOM files in the disc contents the value of any DICOM tag in these files can now be placed on the disc label For more information about configuring this feature see the Virtua Software 3 1 2 Release Notes NOTE this feature does not work with the McKesson HMI interface Enhanced Disc Encryption Features Indicator on the Job Confirmation page that shows whether the Job will be encrypted The Extract feature of encrypted discs is now integrated with the Codonics password entry dialog and does not require use of the separate 7Zip interface For more information see the following Technical Briefs Direct to Disc Codonics Part No 9
10. ity to use non standard fonts on Virtua disc labels Placing font files in the SmartDrive s fonts folder will make the font s available for use on disc labels Spanish French and German voice messages on Virtua E or Virtua C Pressing the Information button on a Virtua E or Virtua C in any of these locales will play audible narrated message in the local language Defects Repaired This section details issues that exist with 3 1 2 software and are corrected in 3 2 0 software Ability for a study to be deleted immediately after recording By setting the Job Profile parameter postProcessingAction to Delete a study recorded with that Job Profile will be deleted immediately after it finishes recording Archived studies will now be re archived if new data for that study is received User interface issue with Hong Kong locale Problems with date formatting distorting the user interface in the Chinese Hong Kong zh_HK locale have been resolved Known Common Issues This section details common issues with 3 2 0 software that are likely to be experienced by most users Process may stop during software installation Leaving the network cable connected may cause installation to stop during Phase 4 Disconnect cable prior to installation Studies can be lost or corrupted if a hard power down occurs Loss of power during some operations can result in lost or corrupt data An uninterruptible power supply and proper shutdown proce
Download Pdf Manuals
Related Search
Related Contents
Topfield v2.0 User's Manual USER MANUAL BoConcept Model 2600 Assembly Instruction Philips SCB5650NB/05 User's Manual Philips Tabletop stand for SoundBar and TV STS1100 Hach sc100™ Controller Ouvrir au format Pdf Témoin du Christ dans le monde arabe Samsung 2494LW Керівництво користувача Samsung C23A550U Manual de Usuario Copyright © All rights reserved.