Home

User`s manual "VENTS TT PRO" ( PDF 2,92Mb )

image

Contents

1. PROFESSIONAL IN LINE MIXED FLOW FANS VENTS TT PRO BY VENTS 2012 Deenergize the fan power circuit prior to all connection adjustment servicing and repair operations Mounting and maintenance are allowed by duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user s manual The single phase power grid must comply with the acting local electrical norms and standards The fixed electrical wiring must be equipped with an automatic circuit breaker The fan must be connected to power mains through an automatic circuit breaker integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3 mm Check the fan for any visible damages of the impeller and the casing before starting installation The casing internals must be free of any foreign objects which can damage the impeller blades Misuse of the product or any unauthorized modification is not allowed The fan is not to be used by children and persons with reduced physical mental or sensory capacities without proper practical experience or expertise unless they are controlled or instructed on the product operation by the person s responsible for their safety Do not leave children unattended and do not let them play with the product Take steps to prevent ingress of smoke carbon monoxide and other combustion products into the
2. Acceptance stamp Date of production Sold name of trade enterprise and stamp of the shop Date of sale V77EN 01
3. case of the customer s performing unauthorised repair of the product in case of performing repair of the product by third persons unauthorized by the manufacturing company in case of warranty period service life expiry in case of the customer s violating transportation rules assuring prevention of damaging and or destruction of the product in case of the customer s violating product storage rules in case of performing unlawful actions by third persons with respect to the product in case of force majeure fire flood earthquake war hostilities of any kind blockade in case of absent seals provided such seals are prescribed by the User Manual or other relevant substituting document in case of unavailable warranty card in case of unavailable payment document to confirm the purchase with indication of the sale date The manufacturing company shall be responsible for defects arising through its fault prior to the moment of transferring the product to the ownership of the customer The manufacturing company shall not be responsible for defects arising after transferring the product to the customer and caused by the customer s violating the rules of transportation storage assembly and operation of the product or by actions of third persons an accident or force majeure circumstances The manufacturing company shall not be responsible for damage to health and property of the customer caused by the custo
4. not exceed 60 C ELECTRONICS CONTROL LOGIC The fan with the timer T is turned into operation after control voltage is supplied by the external switch e g by the light switch to the input terminal LT After the control voltage is off the fan continues to operate within the timer period set by the timer from 2 to 30 minutes To adjust there off delay timer rotate the potentiometer control knob T clockwise to increase and counter clockwise to decrease the off delay time respectively fig 31 Warning The timer circuit is under mains voltage All adjustments are allowed after disconnection from power mains The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments Use the screwdriver to alter the turn off delay time or the humidity threshold Do not use a screwdriver knife etc for adjustment operations not to damage the circuit board The fan model TT PRO U U1 fig 33 is equipped with electronic TSC module speed controller with electronic thermostat for automatic fan speed air flow control depending on air temperature The electrical compartment incorporates 2 control knobs for setting the motor speed for setting the electronic thermostat The fan cover incorporates a LED light thermostat indicator To adjust the thermostat set point rotate the thermostat control knob clockwise to increase the set point and counter clockwise to decrease the thermostat set point To adjust the fan speed
5. air flow rotate the speed control knob in the same way The fan has two operating logics temperature based and timer based operating logics temperature based operating logic TT PRO U This logic is used to keep air temperature to within 2 C In this case the fan switches are rare The motor sets to maximum speed as the temperature reaches the thermostat set point The fan runs with the speed set by the speed controller if the temperature drops 2 C below the set point or if the initial temperature us below the set point timer based operating logic TT PRO Ut This logic is used for exact air temperature control The motor changes its speed more often as compared to the temperature pattern but one speed interval continues at least 5 minutes The motor sets to maximum speed as the temperature reaches the thermostat set point If the temperature drops below the set thermostat point the motor sets to set by the speed controller speed 5 min after the timer countdown If the initial temperature is less the motor starts operating at set speed immediately The fan TT PRO P fig 34 is equipped with a speed controller that enables switching the fan on off smooth speed air flow regulation from minimum to maximum value MOUNTING The fan is suitable both for horizontal or vertical mounting on the floor on the wall or on the ceiling fig 2 as one unit or included into connected in parallel or in series sets fig 3 In ca
6. e contact the trade company where you purchased the product If warranty servicing on the spot proves impossible you will be provided with the necessary information regarding rendering of this service Manufacturer s warranty shall not apply in the following cases in case the customer fails to provide the product in complete according to the package contents specified in the User Manual or other relevant substituting document including any components disassembled by the customer in case of incompliance of the model or marking of the product with data specified on the product packaging and in the User Manual or other relevant substituting document in case of non timely technical maintenance of the product by the customer dust mud oil condensate foreign particles in case of causing external damage to the product by the customer damage shall not apply to external changes of the product required for the product mounting in case of altering the product design or further reworking of the product in case of replacing and using parts units and components of the product not prescribed by the manufacturing company in case of other use of the product other than intended use in case of the customer s violating product operation rules in case of connecting the product to electric mains of voltage exceeding voltage value specified in the User Manual in case of step voltage that resulted in the product failure in
7. ge environment must not contain dust acid or alkali vapours that may cause corrosion of the product parts WARRANTY The fan is manufactured at the factory of Ventilation systems PrJSC hereinafter referred to as the Manufacturer By purchasing this product the customer confirms to have read and agreed to the terms rules and requirements related to operation storage transportation mounting adjustment connection maintenance and repair as well as warranty obligations with respect to this product as set forth in the manufacturer s accompanying documentation to the product The manufacturing company sets forth the warranty period service life of the product as 24 months following the sale date via retail network subject to the customer s ensuring compliance with the rules of transportation storage mounting and operation of the product In case of any malfunction of the product through the fault of the Manufacturing company within the warranty period service life the customer shall have the right to elimination of the manufacturing defects by means of warranty servicing performed free of charge The warranty servicing implies performance of activities related to elimination of defects in the product aimed to provide intended use of the product by the customer The defects are eliminated either by 6replacing or repairing such a product or a part component thereof With the purpose of performing warranty servicing pleas
8. mer s violating the User Manual or other relevant substituting document other use of the product by the customer other than its intended use or by failure of the customer to comply with warnings and other information on the product specified in the User Manual or other relevant substituting document or by the customer s violating the rules of transportation storage mounting maintenance and operation of the product MOUNTING TT PRO 100 125 8 MIN MIN 19 MIN 12 TT PRO 100 125 150 160 200 250 315 MAX A MIN a MIN terminal block for 5 contacts terminal block for 4 contacts 13 TTPROU U1 TT PRO Un U1n ACCEPTANCE INFORMATION www ventilation system com Fan is ready for using
9. room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Transporting medium must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the fan in the environment containing hazardous or explosive materials and vapours i e spirits gasoline insecticides etc Do not close or block the fan intake or extract vents in order to ensure the most effective air passage Do not sit on the fan and do not put objects on the fan Fulfill the requirements stated in this user s manual to ensure long service life of the product Recycle at the end of the service life Do not dispose the product with unsorted municipal trash Compliance with the manual requirements ensures reliable operation and long service life of the product Keep the user s manual available as long as you use the product You may need to re read the information on the product servicing Read the present user s manual carefully before proceeding with installation works N DELIVERY SET The delivery set includes 1 Fan 1 pce 2 Screws and dowels 4 pcs 3 Plastic screwdriver only for modifications with timer 1 pce 4 User s manual 5 Packing box SHORT DESCRPTION The product described herein is a mixed flow inline fan for supply or extract ventila
10. se of the horizontal fan mounting install a straight air ducts segment on side of the intake vent not less than 1 m in case of the vertical fan mounting install an outer hood to prevent water ingress inside the fan The exhaust pipe must be connected to the air duct The mounting sequence is shown in fig 4 12 and 25 30 Wiring diagrams are shown in fig 13 24 Designation of the automatic circuit Automatic breaker on wiring diagram circuit breaker oe G OFF Designations L1 low speed terminal L2 high speed terminal Designation of the external External switch QF automatic circuit breaker switch on wiring diagram S external speed switch ST external switch e g light switch X input terminal MAINTENANCE Clean the product surfaces regularly once in 6 months from dust and dirt fig 35 42 Disconnect the fan from power mains prior to any maintenance operations To clean the fan use a soft cloth and a brush wetted in a mild detergent water solutions Avoid water dripping on the electric components fig 41 Wipe the surfaces dry after cleaning STORAGE AND TRANSPORTATION RULES Transport the product by any transportation vehicle in the original manufacturer s package Store the delivered product in the manufacturer s original packing box in a dry ventilated premise with the temperature range from 5 C up to 40 and relative humidity less than 80 The stora
11. tion of premises heated during winter time The fan is rated for connection to 100 125 150 160 200 250 and 315 mm The fan is equipped with a two speed motor VENTS TT PRO XXX basic modification VENTS TT PRO XXX V modification with a built in speed switch VENTS TT PRO XXX RV modification with a built in speed switch and power cable with a plug fig 32 VENTS TT PRO XXX T modification with a off delayed timer regulated from 2 to 30 minutes fig 31 VENTS TT PRO XXX U U1 modification with a speed controller with electronic thermostat built in temperature sensor and power cable with a plug fig 33 VENTS TT PRO XXX Un U1n modification with a speed controller with electronic thermostat external temperature sensor and power cable with a plug fig 33 VENTS TT PRO XXX P modification with speed controller and a power cord with a plug fig 34 XXX spigot diameter Due to constant improvements the design of some models may slightly differ from that one described in this manual OPERATION RULES The fan is rated for connection to single phase AC 220 240 V 50 60 Hz power mains The fan is designed for continuous operation always connected to power mains Air motion direction in the system must match the pointer on the fan casing Ingress protection rating IP X4 The fan is rated for operation at the ambient temperature ranging from 1 C to 45 The transporting medium temperature must

Download Pdf Manuals

image

Related Search

Related Contents

StarTech.com 20m USB 2.0 Active Extension Cable - M/F  MANUAL DEL USUARIO DEL KITE ESPAÑOL  Philips EcoClassic Standard lamp Halogen Bulb 872790083644800  Kingston Technology ValueRAM 1GB 667MHz DDR2 Non-ECC CL5 DIMM (Kit of 2)    DS9208  Manual de Usuario NOTARIOS  pdf Documentation language en size 0.37 MB  LTP5000 User Manual - Lotos Technology Plasma Cutters and  