Contents

1. 0 63 MOT 34 YyOLVYSALNI 5 10 SECS MINS MINS 200mS 40 MINS DAYS STARTS TIME BASE DAILY STARTS STARTS Uset pay l reser CALIBRATED 25 50 50 7 75 25 90 100 E amp TS Ltd For all your irrigation needs
2. this shows that the previous start time has been set has been set at 06 30 and the clock is now waiting for the 2 start time pushing either common starts or the daily start will be ignored until a new start time is entered that is different to the first start time e g a new start time of 06 31 will be accepted Note that only one start time will be selected by pushing either COMMON STARTS or DAILY START Otherwise the same start would be allocated to all start times All unused starts should be set at 00 00 which is ignored as a start time If you want to start an irrigation sequence at midnight set the nearest start time to either 23 59 or 00 01 All other times are permitted You can program as many starts as you like up to the maximum permitted of eight starts It is not the sequence of starts that determine the irrigation cycles but the times programmed For instance if you program start eight with a time of 06 00 hours and start one with 07 00 hours start eight will run the first irrigation cycle followed by start one Once all starts have been programmed to see and confirm your start times push the button labelled 204 this will sequence through days and related start times A mixture of COMMON STARTS and DAILY STARTS is allowed For instance you may wish to have common starts for Monday Tuesday and Wednesday but different starts for the remaining 4 days 1 Sequence through to the day by pushing the DAILY STARTS button 2
3. to the Common terminal Pump can be selected from the front panel to run or to be turned off Feed Valve if available can also be selected 10 When the panel is running the pump can be turned on or off from the front panel by pushing the tactile switch labelled pump The pump state will be stored in memory and applied the next time that the panel runs 11 Error checking systems continuously monitor the condition of the rotary switches and look for open or shorted solenoid valve circuits A built in sounder Status LED and station indicator give warning of any error condition pulsing at a rate specific for the error condition 12 The duration of all irrigation times can be altered manually by the Percentage control between 90 and 100 13 Evaporation or humidity sensors with an output of 0 5Vdc or 0 20mA dc are sampled integrated and averaged The algorithm calculates the adjusted irrigation time per station from the output of the sensor 14 Stations are skipped if set above zero with no valve attached The error checking system will warn of an open circuit valve at the end of the irrigation cycle 15 The Feed valve can be programmed to any station in serial and to banks of four in parallel 16 Single station serial operation or single parallel bank operation MOUNTING AND WIRING UP THE CONTROLLER REFER TO Remove the four screws holding the front panel to the rear enclosure WITH GREAT CARE r
4. ELECTRONIC amp TECHNICAL SERVICES Ltd INSTALLATION AND USER MANUAL E amp TS IRRIGATION CONTROLLERS Thank you for purchasing an ETS Irrigation controller If treated in accordance with the following instructions it should give a long and trouble free service OPERATIONAL FEATURES 1 The digital clock has large bright red digits and is easy to read 2 8 programmable starts per day seven days per week a total of up to 56 starts per week 3 Those starts can be set for each day from 1 up to 8 in any sequence or for a week at a time with day omission 4 It is recommended that no more than 2 valves be connected per station in serial configuration and one valve connected per station in parallel configuration Each valve is individually time in the parallel configuration 5 Valve base times from 10s of minutes to 1 second or to 0 2 seconds for misting 6 Various types of rainfall sensor can be attached and used to over ride or integrate external irrigation 7 Continual cycling is available for misting No difficult programming is required Simply connect the Mist controller output into the terminal block labelled Latched input Weaning can be achieved by fitting an ETS Mist Wean controller 8 An irrigation cycle can be initiated by an external start device which connects the terminal blocks labelled Mom latch 9 Watering by hand when a solenoid valve is connected to the Hand watering terminal block and
5. Push the SET STARTS button select the start time and accept by pushing the DAILY STARTS push button 3 When you are satisfied with all start times push the button which will return the display to the local time and day SETTING THE IRRIGATION CYCLE Setting the irrigation cycle is very simple 1 Set the time base required by turning the TIME BASE rotary switch to the desired time base 0 2SECS SECS SECS 10 MINS or MINS 10 2 Set the station multiplier to the desired setting from 0 to 9 When a particular knob is set to zero that valve will not be operated and the controller moves through to the next set station For example if the TIME BASE is set to SECS and STN 1 is set to 3 Valve 1 will be on for 3 seconds 3 Set all remaining stations in the same manner SEQUENTIAL OPERATION This mode is normally used on smaller controllers To run it remove the jumper from the terminals labelled PARALLEL located on the lower left centre of the rear board as shown in fig2 When the program runs the LED for station 1 will be illuminated and voltage will be supplied to valve 1 which should open At the end of the time set LED 1 will extinguish and valve 1 will close The program will sequence to station 2 the LED for which will be illuminated and valve 2 should open This process is repeated for each station in turn PARALLEL OPERATION This mode is particularly useful for larger controllers To run it fit the jumper to the te
6. base If time base set to 10 SECS and the station switch to 3 the irrigation time is 30 Secs 4 Push the reset button 5 Push the start button refer FIG 1 digital clock will show PS1 for a max of 4 seconds 6 Controller runs CONTROLLER CARE Very low maintenance required At the end of season keep the mains power applied this will prevent damp entering and corroding metal parts To keep the rotary switch contacts clean turn fully to both end stops DO NOT USE FORCE DON T use sharp or pointed objects to push the tactile switches use fingers only Alarm Conditions 1 Low reservoir 1 beep continuous Lo Res led lit 2 Faulty switch 2 beeps alarm led and station indicator flashes twice 3 Serial open circuit valve short circuit valve 3 beeps alarm led and station indicator flashes 3X 4 Parallel Open or short circuit valve a combination of 3 and 4 beeps 3 and 4 alarm led flashes ELECTRICAL SPECIFICATIONS Operates from a 240V ac mains supply Integral 600 mains suppression filter F2 Mains fused input rated at 500mA slow blow 5 x 20mm 24V ac output for valves and pump relay F4 rated at 1 5A quick blow 5x20mm Low voltage processor supply rated at quick blow 1 amp 5x20mm 30VA 24v ac secondary toroidal transformer maximum output 1Amp Valve common is bonded to Earth Rechargeable clock battery Plastic double insulated enclosure size 240mm x 190mm x 90mm Declaration of Conformity Name of manufact
7. been lost the clock will have to be re programmed A reset action after removal and replacement of the clock suicide jumper will prevent a spurious irrigation cycle Your clock will have been set at the factory and the local time should not require setting However should you wish to alter the time or simply familiarise yourself with the workings here is a step by step guide Note if you reset the clock or if the clock has never been set the display will flash This is perfectly normal Setting the time is the only complicated procedure on this controller However if you can set an alarm clock you will have absolutely no problem in setting this one The clock displays the time in the 24 hour format Clock access is inhibited when an irrigation sequence is running TIME DOES NOT AUTOMATICALLY ADJUST FOR BST AND GMT The days will be displayed as follows MONDAY t TUESDAY WEDNESDAY t FRIDAY S SATURDAY S SUNDAY HOURS MINS DAYS STARTS 42 00 5 L ser DAY By default for new clock hours minutes days will flash As an example it is Tuesday and the time is to be set to 15 30 hours Setting the Local Time Then push the button labelled The hours display will increment count upwards When the clock shows 15 00 release the push button If you release the SET TIME push button before the HOURS push bu
8. both short and open circuit PERCENTAGE ADDITION SUBTRACTION To select addition subtraction place jumper into MAN header on FIG 2 The operator can use a potentiometer labelled mounted on the front panel to increase or decrease all valve times between SCALE 100 and SCALE 90 On hot days you would increase the control on dull overcast days you would decrease the control When the control is set to CALIBRATED the irrigation time is the multiplication time shown on the timer scale as described above Thus 1 if the time on station one was set to 1 and the time base set to 10 SECS the control set to CALIBRATED the irrigation time will be 10 secs 2 If the control were set to 100 the irrigation time would be 20 secs 3 If the control were set to 90 the irrigation time would be 1 second The control will work on the 10 SECS MINS and MINSX10 time bases but it has no effect on the 0 2 SECS and SECS time base Because of the integration software if the percentage is adjusted prior to an irrigation cycle the RESET button must be pushed otherwise the percentage would be averaged This is explained in greater detail in the integration section INTEGRATION To select integration place jumper into AUTO header on FIG 2 and disconnect the lead from HDR2 if fitted Simply put this allows appropriate sensors to adjust the percentage addition subtraction control described above automatically and in response to a
9. cted ALTERING PROGRAM SETTINGS These can be done whilst the program is running simply by increasing or decreasing the station time or by selecting a new time base If you want one station to stop operating simply set the knob to 0 PUMP The pump output is selected by pushing the PUMP CONTROL button when the program runs This state is always remembered even when the panel is turned off This also applies if the pump has been programmed off The PUMP led indicator is lit when the pump is running This output can also be used to operate a master valve a fertilizer injector or similarly related equipment STATUS When all is healthy the TIMER PULSE led will flash at the time base rate for instance if the time base is set to 1 second the TIMER PULSE led will flash at 1 second intervals SINGLE STATION serial SINGLE BANK parallel Initiate an irrigation cycle Push the ADVANCE to select the station or bank to be irrigated Push the FEED VALVE push button once the sounder and Alarm led will bleep and flash twice The selected station bank will irrigate once and when complete the irrigation cycle will reset This feature has to be selected every time an irrigation cycle is initiated Note pushing the FEED VALVE during an irrigation cycle will reset the irrigation cycle after the current station has finished watering DIAGNOSTICS prevention of glass house flooding These are carried out automatically when the program is initiated The
10. ctual conditions A 0 dc signal is sampled every 5 minutes indicated by a pulse of the POWER INT SAMPLE led up to a maximum of 42 hours The controller monitors a signal from an evaporation device such as a Solarimeter an Evaposensor Waterbug or a Delta T device over a Set period usually the period between the controller start times If all parameters have been set up accurately such as the time base and multiplication factor on the station the algorithm converts the voltage input into an accurate frequency and automatically calculates the exact amount of irrigation time to compensate for the evaporation period If sampling exceeds 42 hours which in effect means that no irrigation has been applied for this period all information is cleared and the process repeats The signal from the sensor is sampled digitised and stored every 5 minutes over a maximum period of 42 hours If during this period an irrigation cycle is initiated the sum of the digitised samples is divided by the number of samples taken and the resulting average is used to adjust the watering times Connect the output of your device to the terminals labelled INTEGRATOR and LOWRES OV terminals located on the output board refer to FIG 3 Quick Start 1 Connect controller to the valves pump and mains supply refer to the relevant sections in the installation manual 2 Set the time base 3 Set each station switch remember the 0 9 positions on the switch x the time
11. day by one touch of the button The DAILY STARTS button allocates an individual start time to be programmed for a particular day of the week As an example set the first start time to 06 30 hours 1 Push and hold the button labelled E the real time display will show 00 00 tS1 To set the hours push and hold down SET STARTS and until 06 is displayed Release the HOURS push button 30 is displayed TARTS push button 2 Next push and hold down SET STARTS and Release the MINS pushbutton When you are satisfied that the first start time is correct releas Now allocate that start time to just one day by pushing the button or to all 7 days by pushing the eae button To check release SET STARTS push button and press the again to scroll through stored start times HOURS MINS DAYS _ STARTS aa is Ea 5 DAY JL _ The action window should now show the following information 06 30 461 This shows the first start time has been programmed for 06 30 on Tuesday You can either program the remaining seven starts in the manner described or leave them unused Keeping the DAILY STARTS pushbutton pressed will scroll through the remaining seven starts all should display 00 00 through to Wednesday which should show the first start time as 06 30 61 scroll through to Thursday 06 30 t S1 etc for the rest of the week The second start time will now be displayed as 06 30 t S2
12. e cables clear of the 240vac high voltage supply in accordance with the Low Voltage Directive Please take care to do this CONNECTING THE PUMP The pump cannot be driven directly from the controller Use an appropriate relay with a 24Vac coil and connect the relay coil across terminals PUMP and COMM MORE EXTERNAL INPUTS AND OUTPUTS CONNECTING THE FEED VALVE Connect the solenoid valve across the terminal block labelled FEED and the return to COMM REMOTE STOP LOW RESERVOIR CUT OUT A closed contact across the terminals labelled Lo res OV Lo res will suspend the program The alarm led will flash and the sounder will beep on off until the low reservoir fault condition is removed The program will continue from point of suspension If a float switch is fitted in the water reservoir and connected to the Lo res contacts the program will be suspended when the water level in the reservoir drops below the float switch causing contact closure The program will remain suspended until the water level increases above the float switch and opens the contacts REMOTE STARTS There are two kinds of remote starts momentary and cycling latched 1 A momentary start device such as a closed contact or the output from an Evaporimeter wired across terminals labelled MOMENTARY and common arrow point will start an irrigation program once The clock display will thereupon read PS1 for no more than four seconds PS1 indicates that the start has been form an e
13. ed either open circuit or short circuit the station and valve are skipped and the next station is selected At the end of the irrigation cycle the faulty valve is identified by the station indicator If the valve on station 3 is faulty station 3 led and sounder will beep and flash three times This applies to all 16 48 stations Once the fault condition has been rectified sounder and led will turn off Upon initiation of an irrigation cycle automatic error checking for all outputs occurs In serial this consists of a 120mSec sequential pulse to all outputs Outputs whose stations are set to zero are not checked In parallel each output is checked as above in serial mode and then all outputs in a bank of four are checked all four led s in the bank are on for 120mSec for over current In serial mode short circuit or open circuit conditions give an error warning of 3 beeps and 3 alarm led flashes In PARALLEL where 1 or 3 stations are safely powering 3 valves with the 4 station open circuit valve the 4 station indicator will flash and alarm sounder will beep If one of the stations 1 to3 is short circuited faulty valve error warning will be 3 flashes and 3 beeps open circuit followed by 4 flashes and 4 beeps short circuit If all or one of the stations are left open circuit all station indicators will flash 3beeps followed by 4 flashes and 4 beeps The valve detection circuit will provide a common error for
14. emove the three flat ribbon cables from their respective sockets Please note these are keyed and can only be inserted one way Refit the cables when wiring complete The controller should be mounted on a flat surface and secured by bolts screwed through the holes provided in each corner of the box Do not make other holes in the box for this purpose The ETS controllers should be wired in accordance with FIG 3 IMPORTANT Ensure that the mains supply is disconnected before wiring the controller Ensure that the mains supply is clean and that there are no inductive loads such as large pumps or motors on the same supply It is recommended that the controller be wired directly to the main distribution board We recommend that you protect the controller with an RCD rated at 2 Amps Connect The 240Vac live brown wire to the fused terminal block labelled L The neutral blue to the terminal block labelled N The earth green and yellow to the terminal block labelled E Ensure that the Earth terminal runs to a bonded metal pipe or to a dedicated earth rod and that the impedance to earth is lt 5 Ohms CONNECTING SOLENOID VALVES Connect the solenoid valve 1 to terminal 1 solenoid valve 2 to terminal 2 and so on for the remaining valves Connect the other wire from each of the solenoids to a common return The terminal blocks for this are labelled COMM In the U K it is a statutory requirement that you keep all the low voltag
15. ial Automatic audit When power is applied the controller signs on with a signature tune This indicates that the program is fully functional The power int sample led will be illuminated indicating a healthy 5Vdc power supply SETTING THE DIGITAL CLOCK See FIG 1 You can set the 24 hour seven day digital time clock to the local time days hours x10 hours minutes x10 and minutes The battery backed time base is crystal controlled and highly accurate the local time is updated every minute If the mains power should fail the re chargeable battery back up will ensure accurate time keeping for a minimum of seven days There are 8 automatic programmable start times Start times can be set individually or in blocks The sequence program can be started automatically or manually from the clock The clock can be reset manually and a new time and day can be programmed if so desired The clock program operates a number of safeguards to provide a high degree of fail safe operation If the clock software detects a problem the MINS the MINSx10 and the DAY displays will be visible while the error is being corrected automatically If in the unlikely event that the clock completely freezes and pushing the clock set buttons has no effect remove the jumper labelled CLOCK SUICIDE RESET located on the rear of the main control board FIG 2 This will remove all power from the clock wait for 2 seconds and replace jumper All stored information will have
16. is complete push the ADVANCE button to check stored FEED VALVE data Stored FEED VALVE data is retained indefinitely in the event of a power failure Note that when the feed valve has been selected in a sequence the FEED led flashes twice the sounder beeps twice If feed has not been selected the FEED led does not flash and the sounder is silent INITIATION IRRIGATION CYCLE An irrigation cycle can be initiated in three ways 1 By a timed automatic start 2 By a manual start 3 By a remote start A timed start from the digital clock has been explained in SETTING THE DIGITAL CLOCK When the clock initiates a start the display will show both the real time and what it is doing displayed for example as FS1 Friday start 1 This will be displayed for up to 4 seconds the clock interrupt routine Then the action is cleared from the display which reverts to local time The manual start from the clock is inhibited when hand watering the automatic start sequence from the clock is not affected EXTERNAL STARTS Any device which makes contact across the terminals labeled MOM LATCH or LATCH can be used to start the irrigation program remotely MOM is generally used for starting irrigation programs whilst LTH is generally used to start Misting or cycling programs PROGRAM ADVANCE When the irrigation program is running pushing the Program ADVANCE button will advance the program to the next station In parallel the next bank is sele
17. old FILED 02 03 2003 JOHN WALKER 02 03 2009 4 64 ISOLATED IRRIGATION OUTPUT 26 seat 9 yeu J oca 444 tea ora 1 5 Or Tezy 49 Toza 254 IS Joza gt g _ gt 2 a 0 R7 R6 6531 0931 5941 HDR6 TRF1 wwoos HDR1 9541 Zeal a 1 c14 1 4 ZSNLS GNLS 6SNLS O9NLS 9 16 ZONLS 9 16 VONLS 25 C C Tr65 TB9 H LVI HILV1 WOW 33 5 3 TB12 1 LIVE AlddNS WINOD WINOD WINOD WINOD WINOD WINOD WINOD 1 LNLS ZNLS ENLS 16 SNLS 9 16 4 16 8 16 6 16 0 16 LENLS ZL NLS ELNLS 16 SINLS 9LNLS ZINLS m FIG 3 8LNLS 61315 02 15 LZNLS ZZNLS EZNLS 16 STATIONS N TB15 H LVI HOLVT
18. program checks for open circuit switches At the end of the irrigation cycle the faulty switch is identified by the station indicator station 3 switch is faulty station 3 led and sounder will beep and flash twice This applies to all 16 stations Once the fault condition has been rectified sounder and led will turn off However even with a faulty switch irrigation can safely continue The software will identify the faulty station and will apply a limited amount of irrigation In serial this is 50 of the time base i e if switch 3 were faulty and the time base set to 10 secs irrigation would be applied for 5 seconds In parallel this is 10 or in the example above 1 second This process ensures that the glass house is not flooded but there is limited irrigation on the faulty station Once the faulty switch has been identified rotate the switch vigorously to the left and right this switching action should clean the contacts An application of WD40 may also help To do this pull off cap and squirt down the flat of the spindle Wipe off excess oil FAULTY VALVE on 16 stations and above To select this function insert the 2 way jumper taped to the Output board FIG 3 into the header labelled VALVE SCAN and the 2 way jumper taped to the logic board ito the header labelled VALVE TEST If not required leave VALVE TEST header empty If not fitted the controller will skip the valve test routine In SERIAL If a faulty valve is detect
19. rminals labelled PARALLEL as above Four stations will operate at the same time each for the length of time set when it was programmed When a program starts the LED s for stations 1 2 3 and 4 will be illuminated and the respective 4 valves will open As the stations time out the respective station indicator and valve will close If all the stations are set to the same time all valves and station indicators will open and close together With the 16 station controller bank 1 stations 1 to 4 come on first followed by bank 2 stations 5 to 8 bank stations 9 to 12 and finally bank 4 stations 13 to 16 24 through to 48 stations operate in the same manner PROGRAMMING FOR FEED The software allows the FEED VALVE to be programmed for every station The FEED can be programmed on or off When the panel is in a quiescent state pushing the ADVANCE button will illuminate station one and the FEED VALVE led indicators If feed is to be applied on station one push the ADVANCE button FEED VALVE led will flash twice and the sounder will beep twice station two led indicator is now illuminated If feed is not required on this station push the FEED VALVE push button FEED VALVE led will flash once then extinguish and the sounder will beep once push the ADVANCE button station three indicator will be illuminated Carry on programming in this manner to the sixteenth station In parallel the feed valve is common to the bank of four stations Once programming
20. tton a manual start sequence will be initiated If this is a problem push the reset button to terminate the Sequence 2 Now push the button labelled The minutes display will increment When 30 is displayed release the and the SET TIME push buttons The local time is now set 1 Push and hold the button Next program the action window which displays the Day stored starts and the start information 1 To set the day which by default is set to ways displayed as the DAYS window push and hold the button labelled followed ee When both buttons are held down the days display will increment from Monday through to Sunday When the correct day is displayed release followed by Local time and date are now set HOURS MINS DAYS _ STARTS COMMON STARTS STARTS 5 DAY JL RESET If you mistake at any time simply repeat the above setting procedure If you want to clear everything back to the default level push the button labelled FA and the push button labelled together Setting Start Times When the correct time and day of the week are displayed the start times can be programmed The COMMON STARTS button saves you a lot of time because it allows you to apply a common start time to a particular program for up to seven days Thus if you programmed a start for 06 30 on Monday the same start time can be programmed for Tuesday Wednesday Thursday etc through to Sun
21. urer E amp TS Ltd Full postal address 40 Acreville Rd Bebington Wirral Cheshire CH63 2HY Country of origin UK Description of product Irrigation Controller Conforms to the requirement of the EMC directive 89 336 EEC of low voltage directive 73 23 EEC and harmonised European and national standards Applied standards EN50081 1 EMC generic emission EN50082 2 EMC generic immunity We declare that as the authorised representatives the above information in relation to the manufacture of this product is in conformity with the stated standards and other related documents following the provision of EEC directives Q 6 a 6 eo bid 59 TrA 151 1531 2 6 2ErECL 33 48 2 41 35 20 f0 20 2MILCH 2 10 6 138 151 T gt F l fa g faa 21VEL a HDS H 8 5 pi a E 134 150 0 5 4 SA 2 ita 158 150 z ae LIS 144 10 49 18 7 0 DOD DDDD X IMbNL 10 ONLbNL BOWED 1 5 196599 4012116 20719 HDB2
22. xternal source 2 A latched or cycling start can be initiated by a suitable device wired across terminals labelled LATCH and common arrow point The controller will operate the program for as long as these contacts are closed and can be used for misting multiple cycling and for pulsed irrigation programs The display will constantly read PS1 HAND WATERING A permanent 24v AC supply is available across HANDWATER and COMM When this supply is healthy the LED labelled ValveSupply OK is illuminated Hand watering can be accomplished in two ways i pump selected by pushing the Pump Control push button ii and feed where applicable by selecting Feed Valve push button The pump and feed valve can be turned on off by repeated pushes on their respective buttons The feed valve will always turn off when the pump is turned off The manual start from the clock is inhibited when hand watering the automatic start sequence from the clock is not affected SETTING THE GRASLIN CLOCK Clock has been pre wired please refer to the manufacturers instructions for clock setting NOTE When the clock slide switch is in the ON up position external starts i e momentary starts and latched starts are ignored When the switch is in the AUTO middle or OFF down position external starts will be accepted The external latched start initiates a single cycle similar to the momentary start OPERATIONAL FEATURES IN DETAIL Init