1. ENVIRON AA sonic ee oot witch F o The lonzyme DFII System Y Introduction The Environ IONZYME machine is a patent pending machine which introduces the use of active low frequency Sonophoresis and intensified Iontophoresis treatments The Environ IONZYME DF machine is a supersonic treatment system which produces a 22kHz sound wave These sound waves are generated from the vibration of a special ceramic head and are transmitted through the air Research work has shown that cavitation facilitates penetration of skin and occurs best at lower sound frequencies The Environ IONZYME DF machine has been specially designed for Environ skin care treatments to maximize the enhanced penetration offered by this research and becomes the first machine commercially available with this potency While there are machines available which can supply both galvanic currents and Ultrasound the sonophoresis is done at IMHz to 3MHz The iontophoresis section of the machine allows either a continuous or intermittent current up to a maximum of 20mA For Environ treatments we recommend the use of the intermittent current at the highest mA comfortable The frequency of the sound cannot be altered This machine offers 1 Iontophoresis with continuous or intermittent current 2 Sonophoresis 3 Combined lontophoresis and Sonophoresis through the probe Table of Contents IMPORTANT PRECAUTIONS AND SAFEGUARDS aussen 4 5 TEECENICAG
2. PROBE HEAD 1 Always use the recommended gel This is to prevent the air from going in between the probe head and the skin which will interfere with the effectiveness of the supersonic wave 2 Contact the probe head on the surface of the gel and not directly on the skin and rotate slowly in a circular motion Do not keep the probe absolutely motionless in one area 3 The probe contact angle with the skin should be at 90 degrees 4 Clean the probe by wiping off the gel after treatment 5 Do not immerse the probe head in water or allow water to track up the rod into the black probe holder The moisture will damage the resonator and the special sound will not be produced TECHNICAL INFORMATION INPUT ELECTRICITY 2201 10vAC 50 60Hz POWER 20 Watt Max DIMENSIONS 380mm x 260mm x 120mm WEIGHT 4Kg Aprox WEIGHT PACKED 5 8Kg Aprox THE IONZYME DF II IONZY ME pr O ENVIRON O HEA T TIME F STARI Zus REET 10 eae Thi Triste FOOT SWITCH pa SONIC PROBE A FACIAL PROBE Illustration of the Ionzyme DF II Machine Front Panel 1 Foot switch plug 2 Sonic probe plug 3 Facial probe plug 4 Sonic power selector 5 Sonic indicator light green 6 Ion output selector green for Sonic red for facial probe 7 Ion polarity selector positive or negative 8 Ion power selector 9 Time set selector 10 Start and Stop Button Starts or Stops treatment output 11 Ion mode selector select between Intermittent or C
3. machine The power switch should illuminate red when it is on If there 1s still no power please unplug the machine and check the fuses Error Faulty fuse Solution Switch off and unplug the mains cable from the mains supply Unscrew the fuse holders at the back of the machine Replace the fuses with the correct fuse rating this is indicated next to the fuse holders on the back of the machine Screw the fuse holders back into the machine and plug the mains cable back into the wall socket and turn the machine on Error Timer displays 4 zeros Solution Turn the Ion output control to the off position this should click when properly turned off The time then should indicate the previous setting time setting and then you can proceed with setup Error There is no Sonic output at the Probe Solution Please read the user manual first Refer to page 9 Make sure that the foot pedal and sonic probe are plugged into the machine correctly Start the timer by pushing the start button the timer should then start to count down Check that the Sonic Power button is selected and illuminated green Depress the foot pedal for Sonic the Sonic on indicator will illuminate green when sonic is on Error There is no Iontophoresis output at the Sonic probe Solution Please read the user manual first Refer to page 12 Make sure that the foot pedal sonic probe and Iontophoresis lead with inactive electrode are plugged into the machine correctly Start the
4. main power at the back of the unit This only means that the machine has been powered but there is no power yet to either the Sonophoresis or the Iontophoresis outlets ENVIR Select treatment time by pushing set time Or Buttons Select between 5 and 60 minutes treat ment Default is 20mins By default when the machine is switched on both Sonic and Ion outputs are selected At this point both Sonic and Ion power lights would be flashing Make sure both are flashing indicating both treatments are ready to start Treatment Program Make sure that the Ion output selector is set to Sonic Probe Ensure that the correct Iontophorises polarity has been correctly selected to either positive or negative Select the Iontophoresis mode as Intermittent Inter Place the inactive electrode firmly against the palm or cho sen area Wet the supplied sponge or Haize gauze with water for correct conductivity Apply the selected Environ treatment gel to the chosen area Once you are ready to start your treatment push the start button on the machine to start the timer and the concurrent treatments The timer will start the count down and treatments will begin 13 Make contact with the Sono phoresis probe against the gel on the skin Depress the Sono phoresis control foot pedal plugged into foot pedal output The green Sonic on indicator light will go on Sonophoresis has no
5. the end the machine automatically switches off the power to the Ion outlet A sounder will sound five short indications of treatment end and the display will flash zeros Then the display will reset back to the previous set time If the timer has not reached the end time press the stop button to switch off the timer and end the treatment To reactivate the machine for longer treatment Turn off the Ion output level selector Set the timer to required time of treatment and push the start button to start the treatment again Then turn on the Ion output level control to the desired level Treatment Program For Sonophoresis concurrent with Iontophoresis through the Sono phoresis probe ONZ YME ENVIRON Sm cs 8 12 Firstly ensure that all switches are off including the Ion output control which has to be clicked in the off position Plug in the machine to the mains supply socket Ensure that foot switch lead is fully plugged into the front plug marked Foot Switch Ensure that the Sonophoresis probe is properly plugged into the front panel plug marked Sonic Ensure that the Iotophoresis leads are properly plugged into the facial probe outlet Also see that the attachments are connected to the correct Iontophoresis leads outlets The crocodile clips are not utilised in this method but ensure that the inactive electrode is connected to the black plug Switch on
6. timer by pushing the start button the timer should then start to count down Check that the Sonic Power button is selected and illuminated green Check that the Ion Power button is selected and illuminated red The Ion Output selector must be set to sonic probe Please make sure the client has the inactive electrode from the Iontophoresis lead This should be plugged into the black plug on the lead Make sure you have turned on the Ion Output control to the required setting Error There is no Iontophoresis at the Facial probe outlet Solution Please read the user manual first Refer to page 10 Make sure that the Iontophoresis lead with inactive electrode is plugged into the machine correctly Start the timer by pushing the start button the timer should then start to count down Check that the Ion Power button is selected and illuminated red Make sure the Ion output selector is set to Facial probe Make sure you have turned on the Ion Output control to the required setting Please note If your machine does not function properly please advice your local dealer and do not use the machine until it has be properly serviced All servicing and warrantee work should be done by an Environ Appointed service engineer 14 Made in South Africa Environ Skin Care Pty Ltd Unit G 11 Access Park Kenilworth Cape Town South Africa 21 Marshall House 49 Marshall Street London WIF9BE
7. ODETATES ejer sais Dias needa N E EIER 5 ILLUSTRATION OF THE IONZYME MACHINE FRONT PANEI 222ssssssssesssssssnneseneen 6 ILLUSTRATION OF THE IONZYME MACHINE BACK PANEI 2 22222ssssssessssesesesnennneenen 7 TREATMENT INSTRUCTIONS ME FHOD FOR SONDGPHORFSIS sense ae 9 METHOD FOR FIELD IONTOPHORES S sn sau a E RENAE ianei 10 11 IONTOPHORESIS AND SONOPHORESIS THROUGH THE PROBE 0 eee ees 12 13 TROUBLE SOO TIN Ge ee a ee 15 Warning Please read the instructions carefully before using the DF machine IMPORTANT SAFEGUARDS IN USING THE IONZYME DFII MACHINE PLEASE READ ALL INSTRUCTIONS BEFORE USING THE IONZYME DF II IONTOPHORESIS AND SONOPHORESIS MACHINE WARNING To reduce the risk of burns electrocution fire or injury 1 Always unplug the appliance after use 2 Do not place or store this appliance where it can fall or be pulled into a tub of water 3 Do not place in or drop into water or other liquid 4 Always unplug the machine if there has been any danger of water or other liquids entering the machine 5 Do not expose the appliance to rain or moisture 6 Operate the appliance on the correct voltage for your country or with a suitable transformer 7 The lonzyme DFII machine should never be left unattended when switched on 8 Close supervision is necessary when this appliance is used by on or near children or invalids 9 Use the lonzyme DFII machine only for it
8. e Select the current quality either as continuous or intermittent Intermittent is safer and more effective 10 Treatment Program Make Sure that the Ion output selector is set to Facial probe Place the inactive electrode firmly against the palm or chosen area Wet the supplied sponge or Haize gauze with water for correct conductivity Apply the selected Environ treat ment gel to the chosen area 1 Cover with wet Haize Gauze 2 Attach the active leads to the mask and or roller This pro duces a field of Iontophoresis which can be com bined with the roller if desired for intensive treat ments to certain areas If the roller is being used then make contact with the skin before switching on the current Once you are ready to start your treatment push the start button on the machine to start the timer and Ionto treatment The timer will start the count down and treatment will begin 11 Slowly increase the level of the ion output control dial between 0 2mA and 2mA Try and achieve the highest current that is comfortable to the client The client could experience a tingling or flashing sensation but this should not be uncomfortable or unbearable Should the cl ent complain of discomfort then reduce the Ion output level After the desired duration normally 20mins slowly switch off the Ion output control to the clicked off position When the treatment timer reaches
9. no power yetto the Sono phoresis outlet ONZYME sN RO Select treatment time by pushing ENV pe set time or Buttons Select between 5 and 60 minutes treat ment Default is 20mins By default when the machine is switched on both Sonic and Ion outputs are selected At this point both Sonic and Ion power lights would be flashing To select Sono only de select Ion power button so that flash ing light indicator is off Apply the selected Environ treatment gel to the chosen site for Sonophoresis treatment Touch the surface of the gel with the sonic probe head and slide the probe at moderate speed and pressure over the treatment area Ensure that there is a layer of gel between the probe head and the skin Once you are ready to start your treatment push the start button on the machine to start the timer and sonic treatment The timer will start the count down and the treatment will begin Depress the Sonophoresis control foot pedal plugged into foot pedal output and the green Sonic on indicator light will go on Sonophoresis has now started Treat the selected area for a mini mum of 3 to 5 minutes If more than one area is to be treated then each area has to be treated separately for a minimum of 3 to 5 minutes Remember that activity only takes place on the area directly under the Sonic probe head When the treatment timer reaches the end the machine automatically switches the
10. onstant current 12 Ion output level Adjust between 0 and 2mA The set button can be used for mA setting 13 Ion output indicator lights THE IONZYME DF II gt Illustration of the Ionzyme DF II Machine Back Panel A Mains power plug input 230 110 Volt 50 60hz Warning This device needs to be earthed B Main Fuses C Probe rack D Mains on and off switch Illuminates red when it 1s switched on Other components to be found in the kit Iontophoresis leads Primary The Sonophoresis probe Active Sonophoresis foot control pedal connector connects the inac plate for contacting with Plug fits into the front of the tive electrode or rubber pad treatment gel and skin machine marked Foot Switch Roller or Crocodile clips con Depress on nects into the red pug outlet Mains Lead 220 1 10v AC 50 Facial Probe Roller Crocodile clips to attach to the 60Hz gauze mask Y ENVIRON Treatment Program For low frequency Sonophoresis only Firstly ensure that all switches are off including the Ion output con trol which has to be clicked in the off position Plug in the machine to the mains Ensure that foot switch lead is fully plugged into the front plug marked FOOT SWITCH Ensure that the Sonophoresis probe is properly plugged into the front panel plug marked Sonic Switch on main power atthe back ofthe unit This only means that the machine has been powered but there is
11. ontrols then remove the plug from the wall outlet 21 The DFI machine should only be operated by a qualified Environ Skin Care Therapist 22 Do not open the cabinet housing of the machine 23 Do not use the appliance for other than the intended use 24 SAVE THESE INSTRUCTIONS CHOOSING A GOOD LOCATION 1 Do not place the appliance near heat sources 2 Do not place the appliance in a place subject to direct sunlight excessive dust or mechanical vibration or shock 3 Place the appliance in a location with adequate air circulation to prevent internal heat build up in the unit GROUNDING INSTRUCTIONS This product is for use on a nominal 220 110AC Volt circuit and has a grounding Earth This appliance should be grounded Earthed In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electrical current This appliance is equipped with a cord having a grounding earthed wire with a grounding earthed plug The plug must be fitted into an outlet that is properly installed with and grounded earthed system DANGER Improper use of the grounding earth plug can result in a risk of electric shock If repair or replacement of the cord or plug is neces sary check with a qualified electrician or serviceman if the grounding instructions are not completely under stood or if in doubt as to whether the appliance is properly grounded If it is necessary
12. power to the sonic probe off A sounder will sound five short indications of treatment end and the display will flash zeros Then the display will reset back to the previous set time Ifthe timer has not reached the end time press the stop button to switch off the timer and end the treatment Treatment Program Field Iontophoresis Firstly ensure that all switches are off including the Ion output control which has to be clicked in the off position Plug in the machine to the mains supply socket Ensure that Iontophoresis leads are properly plugged into the ica a es OE EES facial probe outlet Also see that ENVIRON a the attachments are connected GRAKI za to the correct Iontophoresis lead outlets The i crocodile clips are connected to the red plug O Za Z The inactive electrode rubber pad or hand held Rod with sponge or body clips are connected to the black plug Switch on main power at the back of the unit This only means that the machine has e a been powered but there is no power yet to either the Sonic or the Iontophoresis section OND Select treatment time by pushing EN BR set time or buttons Select between 5 and 60 minutes treatment Default is 20mins To select Ionto only de select Sonic power button so that flashing light indicator is off Ensure that the Iontophoresis current has been correctly selected to either positive or negativ
13. s in tended use as described in this manual Only use at tachments recommended by the manufacturer 10 Never operate this appliance if it has a damaged cord or plug or if it is not working properly if it has been dropped or damaged Return the machine to a service centre or dealer for examination and repair 11 Keep the cord away from heated surfaces 12 Never block the air openings of this appliance or place it on a soft surface such as a bed or couch where the air openings may be blocked Keep the air openings free of lint hair and the like 13 Never drop or insert any object into any opening 14 Do not use outdoors or operate where aerosol spray products are being used or where oxygen is being administered 15 Connect this appliance to a properly grounded outlet only 16 Unplug the appliance from the wall outlet if you do not use it for a long time Disconnect the cord by grasping the plug Never pull the cord itself 17 In lightning prone areas unplug the appliance from the wall outlet during an electric storm 18 The appliance is not disconnected from the mains as long as it is plugged into the wall outlet even if the unit itself has been turned off 19 Stop the treatment immediately when irregularity or abnormality of the appliance is noticed during the course of a treatment 20 Always attach the plug to the inlet of the appliance first then plug the cord into the wall outlet To dis connect turn off all c
14. to use an exten sion cord use only a 3 wire extension cord that has a three blade grounding plug and a 3 slot receptacle that will receive the plug on the product IMPORTANT FUSE REPLACEMENT For continued protection against risk of fire replace only with the same type of fuse Note that there is a fuse for both the positive and the negative electrodes CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE THE FUSE ONLY WITH THE SAME TYPE AND RATING ENVIRON GENERAL INFORMATION Please follow these instructions Read the instructions care fully and only begin the treatment after you have completely understood these instructions CAUTION 1 Stop the treatment immediately if pain or excessive heat is felt during the course of the treatment 2 Avoid treatment of the following areas 1 Heart 11 Lower abdominal area when pregnant 111 Eyeball iv Do not use Sonophoresis on the ear or immediately behind the ear 3 Pay utmost attention when applying to an area close to the bone Treatment must not be uncomfortable 4 Persons with a pacemaker may not use the iontophoresis section of the lonzyme DF machine 5 Water based gel is necessary for conducting the sound effectively to the skin This water based gel is also suitable for conducting electricity to the skin 6 Use only recommended Environ products for treat ments Use of other products is not recommended OPERATING THE SONOPHORESIS
15. w started Slowly increase the level of the ion output control dial between 0 2mA and 2mA Try and achieve the highest current that is comfortable to the client The client could experience a tingling or flashing sensation but this should not be uncomfortable or unbearable Should the client complain of discomfort then reduce the Ion output Treat the selected area for a minimum of 3 to 5 minutes If more that one area is to be treated then each area has to be treated separately for a minimum of 3 to 5 minutes To move to next area lift foot from foot pedal and turn the Ion output level down This will avoid the client experiencing any discomfort Put the probe head down on the following area Press the foot pedal and turn the Ion Output level up again Re peat treatment on selected areas At the end of the treatment lift foot off the switch to stop power to the Ultrasonic probe If the timer has come to the end then the output to the sonic probe will end automatically If you require to end the session before the time out push the stop button The end of treatment will be indicated by 5 audible tones and 5 flashing ZETOS Switch off the ion output level control Trouble shooting Error Machine will not turn on Solution Make sure that the mains cable is plugged into the machine and into the mains supply at the wall socket Turn on the switch at the wall socket Turn on the power switch at the back of the