Home
        RTCU Gateway 2 Control Panel User`s Manual
         Contents
1.      lt        gt     Status   Configuration   Plug ins       Property Value  El Client  Port 5001  Max clients 25  Timeout 14400  Encrypt False  Encrypt Key 000000000000000000000    Compress True  Time service True  Keul AABBCCDD       Create Remove    Port    Maximum clients    Timeout    Encrypt    Encrypt Key    Compress    Time service    Key1  Key2  Key3  Key4    Key5       The IP port where the gateway instance will listen for clients     The maximum number of clients that are allowed to connect to the gateway instance   This number is dictated by the license     The time without transactions before the gateway disconnects a client  This is used to  clean up inactive connections that for various reasons have not been closed correctly by  the network    Time is given in seconds    Enables disables encryption of client communication    The encryption key used to encrypt decrypt client communication    The key is 16 bytes long and is written in HEX numbers    Note that all 32 characters must be present or the key   s rejected    Enables disables compression of client communication    Enables disables the  Time  service    Enabling the Time service will allow clients to request the local or UTC time from the  gateway instance by using the gwTimeGet   function    Disabling the Time service will return zero to the clients requesting the time    The access key  1 for the gateway instance clients    The access key  2 for the gateway instance clients    The access key  3 for th
2.  Blackist 1 00    Namelist  when a login request is received from a client   the blacklist plug in will lookup the requested  Node ID  and if the Node ID is found  the login  is denied    The blacklist plug in reads the list of denied  Node 1D s from a XML File  The list will be  updated at a user defined time interval    The File must Follow this Format      lt blacklist  gt     lt node gt     lt id gt 2000001  lt jid gt    lt text gt Message log text lt  text gt                 When removing a plug in  with the  Remove  button   it is removed from the configuration of the gateways but  not from the hard drive     Any running gateways will continue to use the plug in until they are restarted   3 1 4 Menu item  Help    By using the  Help  menu  it is possible to receive help regarding specific items     Help Topics  About       The individual items     e Help topics  e About    3 141 Help   Help topics    This command will start the  Windows Help  system  You will be presented with the contents of the Control  Panel help manual     3 1 4 2 Help   About    This command shows the current version number of the Control Panel program and a copyright notice     About RTCU Gateway 2   Control Panel    Version  3 10    Copyright  C  2014 by Logic 10  Denmark          2015 Logic 10    12 RTCU Gateway 2   Control Panel    3 2 Gateway List    The list on the left side of the Control Panel contains all installed gateway instances     Gatewa Status    Pro   El    E  El         Jem      Cr
3.  Support  LPS  supports the transmission of extended size data packets over the RTCU  Gateway 2     The standard packet size over the RTCU Gateway 2 is 480 bytes and by using LPS this is increased to 4064  bytes     RTCU IDE   RACP operations such as transfer or large files or applications to from the device automatically  take advantage of the LPS functionality when available  The application can take advantage of LPS by using  gwSendPacket   gwReceiwPacket  Please consult the RTCU IDE documentation     Limitations    e Supported by all NX32 architecture devices   e Requires firmware V4 40 or later      Requires RTCU Gateway 2 V3 20 or later        2015 Logic 10    Introduction 3    Time Service   The RTCU Gateway 2 has an inbuilt Time Service which allows central synchronization of the real time clock  for connected clients  The clients can request the local time or the UTC time for a truly universal time  synchronization service  For more information  please consult the RTCU IDE online documentation and the   RTCU Gateway Configuration  section     License   The RTCU Gateway 2 supports 25 clients as default  To allow additional clients  further licenses must be  ordered    Please contact Logic IO for more information        2015 Logic 10       The RTCU Gateway Architecture 5    2 The RTCU Gateway Architecture    The RTCU Gateway 2 is a middleware solution which is used for communicating with remote RTCU units by  using any TCP IP enabled communication media  e g  GPRS or L
4.  The service will be  removed  including its configuration  and the maximum number of clients will be freed for the other gateway  instances    The log files will not be removed     To ensure that no gateway instance is removed accidentally  a pop up dialog is shown which asks for  verification     The gateway instance must be stopped before removing it     3 3 Gateway management    The right side of the control panel contains the management pages        2015 Logic 10      14  RTCU Gateway 2   Control Panel    Status   Configuration   Plug ins    j   Value             Property    El  Monitor             Port 5002  Key GATEWAY  Max clients 4   Client   Log   Monitor                Jove   Reset Apply       The management pages consist of   e Gateway Status    e Gateway Configuration    Gateway plug ins    Any change made on these pages will be committed to the current selected gateway instance in the gateway  list     3 3 1 Gateway Status    The  Status  page is where the gateway instances are controlled and monitored     Y RTCU Gateway 2   Control Panel    File Licenses Plug ins Help       Actions Information  Start Gateway Gateway  Not installed    Startup type  Automatic    St op Gateway    Max  Clients  Unknown  Change startup    Time service     UTC  Unknown  Local  Unknown        lt     gt              2015 Logic IO    Control Panel 15    The  Actions  group contains options for changing the status of the selected gateway instance   The actions supported include starting 
5.  from Logic lO  follow these steps   1  Open the Control Panel   2  Go to the Licenses dialog     3  Press the  Install License  button   4  Select the license file in the file dialog     RTCU Gateway 2   Licenses       Date Clients Gateways   Machine ID   2012 11 07 500 4 BWPC    License holder     Logic IO Aps  Holmboes All   14    8700 Horsens  Denmark             Clients used  O of 500 Gateways used  D of 32 Install License       It is now possible to change the maximum number of clients in the Gateway configuration     3 1 3 Menu item  Plug ins    Plug ins are DLL libraries that can be installed dynamically to extend the functionality of the RTCU Gateway  2   A plug in can be developed by using the free RTCU Gateway 2 plug in developers kit     The  Plug In Manager  dialog is where available plug ins are added and removed        2015 Logic 10      10   RTCU Gateway 2   Control Panel    Plug in manager             To add a plug in  follow these steps     1  Copy the plug in DLL to the  Plugins  folder in the Gateway install directory    This step is not necessary for the standard plug ins that come installed with the RTCU Gateway 2    2  Open the Control Panel   3  Go to the Plug Ins Manager dialog   4  Press the  Add  button and select the plug in DLL in the pop up list     Select plug in    Namelist  dll          When a plug in is added  the Plug In Manager displays the available information about it        2015 Logic IO    Control Panel 1    Plug in manager       CET  
6.  name gt   lt date gt     For example  C  Logs Gateway 2012 08 24 file001 log     Level The level of logging that is used by the gateway instance for the log files   Time kept The number of days the log files are stored on the server before being deleted   File size The maximum size of a log file before the gateway starts on a new file     The size is given in MB        2015 Logic 10      z     RTCU Gateway 2   Control Panel    3 3 3 Gateway plug ins    The  Plug Ins  page is where the plug ins in the gateway instance are configured        RTCU Gateway 2   Control Panel    File Licenses Plug ins Help    Status   Configuration    Plug ins                Property                 lt     gt     Create Remove             On the left side of the page  a list of the plug ins added in the Plug in Manager can be seen   On the right of the page  the available properties for the selected plug in can be seen     Y RTCU Gateway 2   Control Panel    File Licenses Plug ins Help    Status   Configuration   Plug ins    Blacklist Property Value    Namelist                Enable False      File  Refresh interval 10                         The actual properties are specific for the individual plug ins  and the details can be found in the description        2015 Logic IO    Control Panel 21    The  Enable  property is used to enable or disable the selected plug in for the gateway instance  A disabled  plug in will not be loaded by the gateway service     When the configuration is changed  the  Ap
7. AN      One of the most important function of the RTCU Gateway 2 is to allow access to connected units that  operate with a private and or dynamic IP address by mapping the private IP address of a unit to a global IP  address that is accessible by other gateway clients     The RTCU Gateway 2 also includes    e Security functions    e Local remote maintenance      Logging features    e Unit recovery after application failure     The merging of SMS and TCP IP technology is made possible with the Logic IO proprietary VSMS  Virtual  SMS  technology which allows any RTCU application that uses SMS messages to transparently send receive  messages by using either SMS  TCP IP  data call  or a cable connection without any changes to the  software already developed     The RTCU Gateway 2 defined protocol is named  RACP2   Remote Access Communication Protocol REV 2   and is based on the RACP protocol that is used for communicating with RTCU units by using a serial line  connection  please see the separate document that describes the RACP and RACP2 protocols   By using a  standard TCP IP socket interface  the protocol is made extremely simple and easy to implement by the  clients     Logic IO offers a free software library  DLL  that implements the client side of the RACP2 protocol for use in a  Microsoft Windows environment  The source code  written in C  can also be supplied     By using the RACP2 protocol  the RTCU Gateway 2 architecture can be illustrated like this     RTCU2        RT
8. CU Gateway 2    RTCU 3    The client is communicating with the RTCU Gateway 2 by using the RACP2 protocol  The message that has  been sent from the client to the gateway will be forwarded to the RTCU unit by using the TCP IP connection   again by using the RACP2 protocol   The response sent from the RTCU unit to the client will be forwarded  back to the client in the same way     It should be noted that communication between two clients and two RTCU units is also possible by using the  RTCU Gateway 2     To use the RTCU Gateway 2  the client and the RTCU unit need to be supplied with the IP address  port  number  and password of the the RTCU Gateway 2     The RTCU Gateway 2 runs as a Windows service and therefore it runs independently of user logon   A complete RTCU Gateway 2 setup consist of       RTCU Gateway 2 service for managing the message routing and logging to file system on the server        2015 Logic 10    6 RTCU Gateway 2   Control Panel    e RTCU Gateway 2 guard service whose only task it is to restart the gateway service if it stops  unexpectedly   e RTCU Gateway 2   Control Panel which handles creation and management of RTCU Gateway 2 services        2015 Logic 10         s   RTCU Gateway 2   Control Panel    3 Control Panel    The  RTCU Gateway 2   Control Panel  is where the gateways are managed     All configuration of the gateways must be done through this interface     Y RTCU Gateway 2   Control Panel    File Licenses Plug ins Help    Gateway Status   Conf
9. RTCU Gateway 2   Control Panel  User s Manual    Version 3 20       2015 Logic IO         RTCU Gateway 2   Control Panel    Table of Contents    Part    Part Il    Part Ill  1    Part IV    1  2    Part V    Introduction  The RTCU Gateway Architecture    Control Panel    Menulite  ms z           LL    Menuitem File  2 254 214552222822                                    Menu item  Licenses    zioni ann  Menu item  Plug ins sisi  Menu items Help    Eee    Create gate                                Rem ove Gate WAY A S EE T  Gateway management                 esee    Gate W ay Status MD  Gateway Configuration ins  Monitor parameters    neto ire ri irren eee re P rae eere  Client  pa AMES iii prote eee m repete pie eda  Log parameters nv nen fn er E E Re nn  Gate EVAUIEU TE mme    Standard Plug ins    Blacklist EUER  NaMeElIST 2 Diada    Trouble Shooting Guide    Index       2015 Logic 10       2 RTCU Gateway 2   Control Panel    1 Introduction    The RTCU Gateway 2 is a middleware solution that allows easy communication and access to remote units  connected by using TCP IP communication technology  The product works in any network architecture and  constitutes a backbone in the communication between RTCU units and back end client applications     The RTCU Gateway 2 fully supports the advanced RTCU Deployment Server  RDS  which is available as a  free add on     The features include     e Advanced server architecture that supports thousands of clients and massive traffic    It ru
10. and stopping the gateway instance and changing the startup type     The  Information  group contains the status ofthe gateway instance   The items can have the following states     Gateway   Running The gateway instance has been started and is running   Stopping     The gateway is currently stopping    Stopped The gateway instance is not running    Not installed No gateway instances are installed     Startup Type    Automatic The gateway instance starts automatically with Windows   Manual The gateway instance must be started manually from the Control Panel   Unknown No gateway instances are installed     Maximum Clients  Clients The maximum number of clients that can connect to the gateway instance   Unknown The gateway instance is not running     Time Service    Time The current time of the gateway instance   shown in both UTC and local time     DST   is added if Daylight Saving Time is in effect    Unknown The gateway instance is not running and or no time information is available    Disabled The time service is disabled for the gateway instance     Y RTCU Gateway 2   Control Panel    File Licenses Plug ins Help    Gatewa Status   Configuration   Plug ins      A Information    ctions  Start Gateway Gateway  Running  Stop Gateway Startup type  Automatic  Max  Clients  25  Change startup    Time service     UTC  2012 11 07  19 50 31  Local  2012 11 07  20 50 31     gt     Create   Remove                2015 Logic 10      16   RTCU Gateway 2   Control Panel    3 3 2 Gateway Co
11. e failed    buffer overflow       Client or monitor cannot  connect      An elevated log level may lead to a  huge amount of storage data     The log file system cannot keep up   This may be a result of    1  No more disk space    2  Slow disk performance     Please note that when this message  occurs  the log information will be  incomplete as not all messages are  saved     Normally this is the result of     1  Missing port forwarding in gateway        2  Connection block by firewall     Please check your Log parameters     Possible solutions   1  Remove old log files   2  Lower the log level in Log    arameters     Possible solutions   1  Check your gateway configuration   2  Check your firewall configuration         2015 Logic 10    about 11  Ls  close 8    configuration 16  configuration  client 18  configuration  log 19  configuration  monitor 17  create gateway 12     H     help 11  help  about 11  help  topics 11    ls    license 9    plugins 20  plugins  manager 9     R     remove gateway 13    Su    Standard Plug ins 23   Standard Plug ins  Blacklist 23  Standard Plug ins  Namelist 23  Status 14       2015 Logic 10    
12. e gateway instance clients    The access key  4 for the gateway instance clients     The access key  5 for the gateway instance clients        2015 Logic 10    Control Panel   19      Key6 The access key  6 for the gateway instance clients   Key7 The access key  7 for the gateway instance clients   Key8 The access key  8 for the gateway instance clients   Key9 The access key  9 for the gateway instance clients   Key10 The access key  10 for the gateway instance clients     All access keys are equal and work similarly  and up to 10 available keys can conveniently be managed     3 3 2 3 Log parameters       RTCU Gateway 2   Control Panel    File Licenses Plug ins Help    Gatewa Status   Configuration   Plug ins       Property  Monitor  Client  El   Log  Max entries 50000  Folder C  Program FilessLogic 101     Level Errors and events  Time kept 14  File size 50    Log        lt     gt     Maximum entries The maximum number of log entries that can be held in the server buffer  The server  buffer is used by the monitor tool clients to read past log entries   The default is 50 000 entries  Legal values range from 1 000 to 500 000  Increasing this  number will also increase the memory footprint of the gateway instance        Folder The directory path the gateway instance uses when logging to files  The gateway  instance will create a folder with the gateway name in this directory  and in this a folder  for each day is created    The log files are stored in  lt folder gt   lt gateway
13. eate Remove       To manage a gateway instance  select it in the list and use the gateway management pages to configure it   A new gateway can be created with the  Create  button if there are gateway licenses left     To remove a gateway  select it a press the  Remove  button     3 2 1 Create gateway    Pressing the above button will open a dialog to create a new gateway instance on the server     Create Gateway    Mame of the new Gateway instance           E Client   Port 5001   Max clients 25   Key AABBCCDD  E Monitor   Port 5002   Key GATEWAY             2015 Logic IO    Control Panel 13    Press the  OK  button to create the gateway instance   Press the  Reset  button to reset the configuration back to default values   Press the  Cancel  button to abort creating the gateway instance     Name of the Gateway Instance   The name of the gateway instance is used to identify the instances and differentiate them from each other    both for the server and the administrator    The name is a Unicode string that can be up to 30 characters long  For example  Gateway  5001       Configuration    The description of the configuration parameters  and additional options  for client and monitor can be found  here       Client parameters    Monitor parameters    The parameters that are not included in this dialog will hold default values and cannot be changed until after  creation     3 22 Remove gateway    Pressing the above button will completely remove a gateway instance from the server 
14. iguration Plug ins       Actions Information    Start Gateway Gateway  Running  Stop Gateway Startup type  Automatic  Max  Clients  25  Change startup    Time service     UTC  2012 11 07  19 50 31  Local  2012 11 07  20 50 31     gt     i Remove             The interface can basically be split into two areas   the Gateway list and the Gateway management areas     3 1 Menuitems    The following pages describe all the different menu items that are available in the Control Panel     Y RTCU Gateway 2   Control Panel       File Licenses Plug ins Help    e File  e  icenses  e Plug ins    Help    3 1 1 Menu item  File  The  Exit  command ends the Control Panel program     AER Licens  Exit            2015 Logic IO    Control Panel 9    3 1 2 Menu item  Licenses    The  Licenses    dialog shows the licenses that are installed on the server    When no license is installed  the RTCU Gateway 2 accepts 25 clients on a maximum of 32 gateways   For example  it is possible to create one gateway with all 25 clients or two gateways   one with 15 clients  and one with 10 clients     RTCU Gateway 2   Licenses         Machine ID     Clients Gateways      BWPC    License holder       Unlicensed          Clients used  0 of 25 Gateways used  0 of 32 Install License       Additional licenses can be ordered from Logic IO to support more clients and gateways   Each license is bound to the Machine ID of the server  This information is therefore required when ordering     To use the license file received
15. nfiguration    The  Configuration  page is where the configuration of the selected gateway instance is managed        RTCU Gateway 2   Control Panel    File Licenses Plug ins Help             ELITR    Property Value   El   Monitor  Port 5002  Key GATEWAY  Max clients 4  Client  Log   Monitor    lt     gt              When the gateway configuration is changed  the  Apply  and  Reset  buttons are enabled        T    Press the Apply button to save the configuration  The gateway will use the new configuration when it is  restarted   Press the Reset button to clear all changes made to the configuration     For a description of the individual parameters  follow the links below     Monitor parameters    e Client parameters    Log parameters       2015 Logic IO    Control Panel    3 3 2 1 Monitor parameters       RTCU Gateway 2   Control Panel    File Licenses Plug ins Help      Status   Configuration   Plug ins          Property Value  E Monitor  Port 5002  Key GATEWAY  Max clients 4  Client  Log          Create Remove       Port The IP port where the gateway instance listens for any monitor tool clients   Key The access key for the monitor tool clients     Maximum clients The maximum number of monitor tool clients that are allowed to connect to the gateway  instance  The default is 4 clients but up to 10 is supported        2015 Logic 10      18   RTCU Gateway 2   Control Panel    3 3 2 2 Client parameters    Y RTCU Gateway 2   Control Panel    File Licenses Plug ins Help    Gatewa
16. ns as a Windows service  This means that the gateway service will start without Windows log on and  can also be managed remotely as a service    Available in a 32 bit and a high performance 64 bit version    Support for up to 32 separately configurable and isolated gateway instances    Remote access via the included  Monitor  tool client    Full password protection for remote access    Up to 10 client keys are supported for more flexible password management    Disconnect timeout for inactive clients    Advanced filtering feature which allows monitoring logging on a specific client and or logging level   Encrypted traffic for safer communication    Compressed traffic  This reduces the cost of communication    Comes with a comprehensive user documentation    Time service for centralized client time management  local UTC     Up to 10 monitor tool clients can be connected simultaneously    Plug in architecture for extending functionality and integration to backbone applications    Plug in developers kit available for free    Free for use of up to 25 clients  The license must be purchased for additional clients gateways     System Requirements  Operating Windows 8 Windows 7 Vista 2003 Server 2008 Server 2010 Server   System   Memory  200 MB   4 kB per client   Hard disk 3 MB   space  Additional space required for log to files   Other  Network card   TCP IP network protocol    Permanent Internet connection with fixed IP address is recommended      Large Packet Support  Large Packet
17. nutes     Blacklist Data File  The data file used by the Blacklist plug in is an XML file with the following format       blacklist      node     lt id gt 2000001 lt  id gt    lt text gt Message shown in log on rejection lt  text gt    lt  node gt    lt node gt    lt id gt 2000002 lt  id gt    lt text   gt    lt  node gt    lt  blacklist gt     4 2 Namelist    The  Namelist  plug in allows the monitor tool to show a symbolic name text in the  Clients  list instead of  the Node ID    The Node ID to name mapping is read from a data file at regular intervals  This ensures that the list of names  for the Node IDs can be changed without having to restart the gateway instance        2015 Logic 10      z    RTCU Gateway 2   Control Panel    Namelist Configuration  File The name of and the path to the data file     Refresh The number of minutes between the plug in checks the data file for changes   interval The default is 10 minutes  This must be a value between 1 and 30 minutes     Namelist Data File  The data file used by the Namelist plug in is an XML file with the following format      lt namelist gt    lt node gt    lt id gt 11110000 lt  id gt    lt name gt RDS server lt  name gt    lt  node gt    lt node gt    lt id gt 11110001 lt  id gt    lt name gt RDS monitors lt  name gt    lt  node gt    lt  namelist gt        2015 Logic 10         z     RTCU Gateway 2   Control Panel    5 Trouble Shooting Guide   Error  Reason     Server is running low on  disk space       Logging to fil
18. ply  and  Reset  buttons are enabled     T       Press the Apply button to save the configuration  The gateway will use the new configuration when it is  restarted     Press the Reset button to clear all changes made to the configuration        2015 Logic 10       Standard Plug ins 23    4 Standard Plug ins    The RTCU Gateway 2 includes a plug in framework for easy extension of the gateway functionality     The following standard plug ins are included in the RTCU Gateway 2 server installation     e Blacklist This plug in will prevent clients from connecting to the gateway based on their Node ID   e Namelist This plug in allows the monitor tool to show a text string instead of the Node ID for clients     A plug in can be developed by using the free  RTCU Gateway 2 Plug In Developers Kit  that also includes the  full source code to the above plug ins     4 1 Blacklist    The  Blacklist  plug in will compare the Node IDs of all clients that try to log on to the gateway with an  internal list  and if the Node ID is found on the list  the logon is denied    The internal list is read from a data file at regular intervals  This ensures that the list of Node IDs that are  denied logon can be changed without having to restart the gateway instance     Blacklist Configuration  File The name of and the path to the data file     Refresh The number of minutes between the plug in checks the data file for changes   interval The default is 10 minutes  This must be a value between 1 and 30 mi
    