1. Limit implemented with analog 200 MHz 20 MHz and digital filters IIR FIR DL9040 9040L 9140 9140L DL9240 9240L 5 GS s 10 GS s 2 5 GS s 5 GS s 2 5 TS s 2 5 TS s DL9040 9140 9240 DL9040L DL9140L DL9240L 2 5 MW 6 25 MW 500 ps div to 50 s div steps of 1 2 5 0 001 0 01 10 ps 1 sample interval When using 1 25 MW 60 waveforms sec ch When using 12 5 kW 9000 waveforms sec ch When using 2 5 kW 25000 waveforms sec ch 400 ns or less equivalent to 2 5 M waveforms sec Auto Auto Level Normal Single and N Single Signals applied to measurement input terminals Connected commercial power signal only available with Edge trigger Signal input from EXT TRIG IN terminal 4 divisions from the screen center 2 V 1 1 20 V 10 1 when used with a probe 0 01 div 5 mV 1 1 50 mV 10 1 when used with a probe Separately configurable on each of channels CH1 to CH4 4 divisions from the screen center 4 divisions from Center Trigger level accuracy CH1 to CH41 EXT Trigger sensitivity CH1 to CH41 1 divp p EXT 100 mVp p where Edge OR1 1 divp p Trigger types Edge State Edge Edge Qualified Edge OR State Width Pulse Pulse Qualified Pulse State Time width setting mode More than Less than Between Out of Range Time out Specified time T1 T2 Time accuracy Event Interval Event Cycle Event Delay Event Sequence Time width setting mode Specified
2. Rubber leg cap SS S 6 Accessories Optional o Name Model __ Specification __ 10 MQ 10 1 500 MHz 1 5 m one per order requires P2 option on the DL9000 for Power Supply Analysis G4 option Accessories sold separatel Doo Name O
3. Probe interface terminal front panel No of terminals 4 Supported probes PBA2500 PBD2000 PB500 Probe power terminal P2 option rear panel No of terminals 2 Supported probes FET probe 700939 current probes 701930 701931 701932 701933 and differential probes 701920 701921 701922 Storage Internal storage media Capacity 90 MB Flash ROM Usage Saving and loading of waveforms and panel settings Internal Hard Drive C8 Option Capacity file system 40 GB FAT32 File name Supports long file names of up to 256 ASCII characters USB Peripheral Connection Ports Connector USB type A connector x 2 Supported transmission standards LS Low Speed mode 1 5 Mbps FS Full Soeed mode 12 Mbps Supported devices USB HID Class Ver1 1 compliant mouse 109 keyboard USB Printer Class Ver 1 0 compliant printers EPSON Ink Jet Printers HP PCL Ink Jet Printers USB Mass Storage Class Ver 1 1 compliant mass storage device USB hub device 1 unit only Please contact your local Yokogawa sales office for model names of verified devices Max No of devices 4 PC Card Interfaces Number of slots 2 front panel 1 rear panel 1 Supported cards GPIB card National Instruments NI PCMCIA GPIB card Flash ATA memory card PC card TYPE Il CF card adapter card and various hard disk type PC cards Please contact your local Yokogawa sales office for model names of verified devices For det
4. Zoom and voltage Vertical Zoom axes Independent zooming factors can be applied to two zoom areas Voltage axis zoom factor 1 to 10 times Time axis zoom factor 1 time to 1data div Auto scroll function Automatically scrolls the zoom window along the time axis Search function Searches the currently displayed waveform for a specified portion occurring beyond a specified time and displays the zoomed result on the screen Search types Edge Edge Qualified State Pulse Pulse Qualified Pulse State Serial Pattern 1 C optional SPI optional History memory Max data DL9040L 9140L 9240L 2000 2 5 kW when using history 1600 2 5 kW when in N single mode DL9040 9140 9240 1000 2 5 kW when using history 800 2 5 kW When in N single mode History search Searches for and displays waveforms from the history memory that meet specified conditions Search types Rect WAVE Polygon Parameter Measure FFT XY Replay Automatically replays history waveforms Display Selected acquisition or Average Avg Cursor measurements The following five cursors can be selected Vertical Horizontal VT Marker Serial Automatic measurement of waveform parameters Performs automated measurement of the following waveform parameters Items unrelated to cycle which will be derived out of all data in the range MAX MIN HIGH LOW P P HIGH LOW OVER OVER RMS MEAN Sdev IntegTY Items related to cycle which will be derive
5. 4 can be configured Detailed data display mode Time from the reference point data simultaneous binary and hex representations presence absence of ACK R W address or data start condition Simple display mode Data hex representation R W start condition presence absence of ACK address or data Analyzable number of data items 40 000 bytes max eSearch function Pattern search Searches data that agrees with the preset address pattern data pattern and acknowledge bit condition eAnalysis result save function Storage of analysis list data The data can be saved to CSV format files SPI Bus Analysis Functions optional e Trigger function Mode 3 wire 4 wire Bit order MSB LSB Source Clock signal SCK CH1 to CH4 Data 1 MOSI CH1 to CH4 Data 2 MISO CH1 to CH4 CS signal SS CH1 to CH4 eAnalysis function Analyzable number of data items 40 000 bytes max Display of analysis results Analysis results can be displayed using the following 2 methods Simple analysis result list Data hex representation CS signal status Detailed analysis result display Detailed analysis result list time from the reference point data select and show either Binary or Hex data and CS signal status can be displayed eSearch function Pattern search Waveforms can be searched by specifying data pattern When a waveform that agrees with the pattern is found the zoom box moves to the position of that waveform
6. Main Specifications Models Model name No DL9040 701307 DL9040L 701308 DL9140 701310 DL9140L 701311 DL9240 701312 DL9240L 701313 Basic Specifications Input channels Input coupling Input impedance Voltage axis sensitivity Maximum input voltage DC offset max setting range When probe attenuation set to 1 1 Vertical voltage axis sensitivity DC accuracy Offset voltage axis accuracy Voltage standing wave ratio VSWR Frequency characteristics Max sampling rate Freq BW Max record length 5 GS s 500 MHz 2 5 MW 5 GS s 500 MHz 6 25 MW 5 GS s 1 GHz 2 5 MW 5 GS s 1 GHz 6 25 MW 10 GS s 1 5 GHz 2 5 MW 10 GS s 1 5 GHz 6 25 MW 4 CH1 to CH4 AC DC GND DC50Q 1 MQ 1 0 approx 20 pF when using PB500 probe 10 MQ 2 0 approx 14 pF 50 Q 1 5 For 1 MQ input 2 mV div to 5 V div steps of 1 2 5 ranges For 50 Q input 2 mV div to 500 mV div steps of 1 2 5 For 1 MQ input 150 Vrms CAT For 50 Q input 5 Vrms or less and 10 Vpeak or less For 1 MQ input 2 mV div to 50 mV div 1 V 100 mV div to 500 mV div 10 V 1 V div to 5 V div 100 V For 50 Q input 2 mV div to 50 mV div 1V 100 mV div to 500 mV div 5 V For 1 MQ input 1 5 of 8 div offset voltage accuracy For 50 Q input 1 5 of 8 div offset voltage accuracy 2 mV div to 50 mV div 1 of setting 0 2 mV 100 mV div to 500 mV div 1 of setting 2 mV 1 V div to 5 V d
7. ailed specifications visit our homepage at USB PC Connection Ports Connector USB type B connector x 1 Supported transmission standards HS High Speed mode FS Full Speed mode Supported class Operates as a multifunctional device simultaneously supporting the following two protocols USBTMC USB488 USB Test and Measurement Class Ver 1 0 A USB bus can be employed to use GPIB commands Mass Storage Class Ver 1 1 The DL9000 s internal storage media hard disk PC card and USB mass storage device can be accessed read write from a PC formatting is not supported Ethernet Communication C10 and C8 Options Connector type RJ 45 connector x 1 Transmission method Ethernet 100BASE TX 10BASE T Supported services DHCP DNS Microsoft network file sharing server amp client FTP server SNTP client SMTP client Firewall functions network printers will be supported in the near future General Specifications Rated supply voltage 100 to 120 V AC 200 to 240 V AC automatically selected Allowable supply voltage fluctuation range 90 to 132 V AC 180 to 264 V AC Rated supply frequency 50 60 Hz Allowable power supply frequency variation 48 to 63 Hz Maximum power consumption 300 VA Withstanding voltage between power supply and case 1 5 kV AC for one minute 350 W x 200 H x 178 D mm when printer cover is closed excluding handle and protrusions External dimensions Weight Approx 6 5 kg including p
8. ations e Power supply analysis function G4 option Propagation time difference correction deskew The difference in propagation time of voltage and current probe signals can be automatically or manually corrected Correction range is 80 ns 0 01 ns resolution Automated measurement of power supply analysis parameters Power supply analysis parameters can be measured automatically and simultaneously with standard measurement items waveform parameters Voltage channels Umn Urmn S P Q Z A Wp Wp Wp Abs Wp UP P P P U pk Max U pk Min Udc C Mean Urms C Rms Uac C Sdev Current channels Imn Irmn q q q Abs g I2t IP P P P I pk Max I pk Min Idc C Mean Irms C Rms Iac C Sdev Automated measurement of two areas is also possible Statistical processing of measured values Enables computation of statistics Min Max Ave o from measured values of power supply analysis items Waveform computation of power supply analysis parameters Active power impedance Joule integral and FFT waveform computation can be performed simultaneously with standard waveform computations Harmonic analysis Allows for easy comparison with limit values per harmonic current emission standard IEC 61000 3 2 edition 2 2 and EN61000 3 2 2000 Trend display Changes over time of waveform parameter values measured every cycle can be displayed as trends in a list and graph History search History search can be performed using power su
9. d out of all data in the range C rms C mean C Sdev C IntegTY 1 FREQ FREQ COUNT BURST Items which will be derived from the first encounter from the beginning of the specified range WIDTH WIDTH PERIOD DUTY RISE FALL DELAY Telecom test Performs mask test and eye pattern measurement Mask test items Wave Count Wave Count Sample Point Count Sample Point Count Vtop Vbase stop sbase Tcrossing1 Tcrossing2 Vcrossing Crossing Eye Height Eye Width Q Factor Jitter Duty Cycle Distortion Ext Rate dB Rise Fall Computes up to eight traces CH1 CH4 M1 M4 INTEG COUNT EDGE COUNT ROTARY Through Delay Moving Avg LowPass High Pass Stuff Bit CAN option Display and analysis computation and cursors of up to four traces M1 M4 of the saved waveform data Waveforms including history can also be loaded for history searches or replay Various parameters can be changed however waveforms are not affected by T Div changes Automatically measured waveform parameters and waveform zones are determined and the selected action is carried out each time conditions are met Eye pattern items Computation functions Reference functions Action on trigger Modes OFF All Condition GO NOGO Zone Param GO NOGO Telecom Test Actions Buzzer Print Save Mail All conditions After EXEC is pressed the specified action is performed upon each acquisition GO NOGO zone Determines whether o
10. igger occurs on 1st occurrence of Event 2 that satisfies the timing constraints The trigger process is reset if Event 1 or Event 2 occurs before the timing constraints are satisfied After Event 1 occurs trigger occurs on 1st occurrence of Event 2 that satisfies the timing constraints The trigger process is reset if Event 1 occurs before the timing constraints are satisfied Function identical to the time width setting mode for Width 1 5 ns to 10 s 500 ps resolution 0 2 of setting 1 ns Events can be selected from Edge Edge Qualified State Pulse Pulse Qualified Pulse State 1 C CAN SPI and Serial trigger types TV Trigger occurs on video signals of various broadcasting system formats Mode Input CH Sync Guard Line Field Frame Skip PC Mode SPI Mode CAN Bit rate Input channel Mode Serial pattern Max bit rate Max bit length NTSC PAL HDTV USER CH1 CH4 Hsync 60 to 90 increments of 1 5 1054 NTSC 2 1251 PAL 2 1251 HDTV 2 2048 USER 1 2 X 1 2 4 8 Triggers on 12C bus signals NON ACK Every Start General Call Start byte HS Mode ADR amp DATA Triggers on SPI serial peripheral interface bus signals 3 wire 4 wire 1 Mbps 500 kbps 250 kbps 125 kbps 83 3 kbps User freely settable in 100 bps increments CH1 to CH4 Input through differential probe SOF Frame ID Data field Remote Frame Error Frame Ack etc Triggers on general purpose seria
11. iv 1 of setting 20 mV 1 5 or less within frequency bandwidth typical value Attenuation point of 3 dB when inputting a sinewave of amplitude 2 div or equivalent For 50 Q input 0 5 V div to 10 mV div 5 mV div 2 mV div DL9040 9040L DL9140 DL9140L DL9240 DL9240L DC to 500 MHz DC to 1 GHz DC to 1 5 GHz DC to 400 MHz DCto 750MHz DCto1 GHz DC to 400 MHz DC to600MHz DC to 750 MHz For 1 MQ input from the probe tip when using the PB500 dedicated passive probe 5 Vidiv to 10 mV div 5 mV div to 2 mV div Residual noise level A D conversion resolution Bandwidth limit Max sampling rate Real time sampling mode Interleave mode ON Interleave mode OFF Repetitive sampling mode Maximum record length Time axis setting range Time base accuracy Time axis measurement accuracy Max acquisition rate Min dead time N single Trigger Section Trigger modes Trigger source CH1 to CH4 LINE EXT Trigger level range CH1 to CH4 EXT Trigger level setting resolution CH1 to CH4 EXT Window comparator Center Width DC to 500 MHz DC to500 MHz DC to 500 MHz DC to 400 MHz DC to400 MHz DC to 400 MHz 0 4 mV rms or 0 05 div rms whichever is larger typical value 8 bit 25 LSB div For each channel select from FULL 200 MHz 20 MHz 8 MHz 4 MHz 2 MHz 1 MHz 500 kHz 250 kHz 125 kHz 62 5 kHz 32 kHz 16 kHz and 8 kHz separately configurable on each of channels CH1 to CH4
12. l communication signals 50 Mbps 128 bits Display Display Display screen size Total number of pixels Waveform display resolution 8 4 inch 21 3 cm color TFT liquid crystal display 170 5 mm width x 127 9 mm height 1024 x 768 XGA 800 x 640 eneration Main Specifications Functions Waveform Acquisition Display Functions Acquisition modes Selectable from three acquisition modes Normal Average and Envelope High resolution mode Vertical resolution is increased to max 13 bits Repetitive sampling mode Allows switching between realtime and repetitive sampling in certain time axis settings Interpolates actual sampled data by up to 1000 times or up to 2000 times in High Res mode and increases the time resolution up to 2 5 TS s Roll mode Roll mode display is enabled during the following time axis range when the trigger mode is Auto Auto Level or Single 100 ms div to 50 s div Interpolate function Record length DL9040L 9140L 9240L 2 5 kW 62 5 kW 12 5 kW 25 kW 62 5 kW 125 kW 250 kW 625 kW 1 25 MW 2 5 MW 6 25 MW DL9040 9140 9240 2 5 kW 62 5 kW 12 5 kW 25 kW 62 5 kW 125 kW 250 kW 625 kW 1 25 MW 2 5 MW Accumulation Accumulates waveforms on the display Choose Count Time and Inten Color Snapshot Retains the current displayed waveform on the screen Analysis Functions Search and Zoom function Zooms the displayed waveform along the time Horizontal
13. ms Frame type time from trigger point frame ID DLC data CRC presence absence of Ack LIN analysis display items ID ID field data checksum information e Auxiliary analysis functions Data search functions Search conditions CAN Top of frame ID data remote frame error frame Search conditions LIN Synch field ID data field jump function CAN Stuff bit computation function CAN e Analysis results saving function Detailed analysis list Can be saved to file in CSV format Model and Suffix Codes of DL9010 9010 9240 _SuffixCode _ Descripton DL9040 digital oscilloscope 500 MHz max 5 GS s 2 5 GS s ch 701308 701310 701311 701312 701313 Power cable F73 DL9040L digital oscilloscope 500 MHz max 5 GS s 2 5 GS s ch DL9140 digital oscilloscope 1 GHz max 5 GS s 2 5 GS s ch DL9140L digital oscilloscope 1 GHz max 5 GS s 2 5 GS s ch DL9240 digital oscilloscope 1 5 GHz max 10 GS s 5 GS s ch DL9240L digital oscilloscope 1 5 GHz max 10 GS s 5 GS s ch 2 outputs for 900 MHz FET probe and current probe 1 Specify this option when using current probes or differential probes such as models 701920 or 701922 2 When specifying one of each must be specified 3 When specifying one or the other must be specified 12C CAN LIN and SPI bus triggers come standard Standard Accessories 3 prong to 2 prong adapter PB500 passive probe
14. pply analysis parameters in the same manner as standard measurement parameters GO NO GO judgment GO NO GO judgments can be made using power supply analysis parameters as well as standard measurement parameters Saving harmonic analysis results Results of harmonic analysis can be saved to CSV files e User defined math G2 The following operators can be arbitrarily combined in equations X ABS SQRT LOG EXP LN SIN COS TAN ASIN ACOS ATAN INTEG DIFF BIN DELAY P2 value squared CAN amp LIN Bus Analysis Function Specifications Applicable bus CAN version 2 0A B 1SO11898 ISO11519 2 LIN rev 1 3 2 0 Bitrate CAN 1 Mbps 500 kbps 250 kbps 125 kbps 83 3 kbps 33 kbps User can be set arbitrarily at 100 bps resolution LIN 19 2 kbps 9 6 kbps 4 8 kbps 2 4 kbps 1 2 kbps User can be set arbitrarily at 10 bps resolution e Trigger functions come standard Trigger source CH1 CH4 CAN input via differential probe Trigger types CAN SOF frame ID data field can be specified with up to 8 bytes remote frame error frame Ack frame ID data OR up to four ID data and Ack trigger conditions can be specified in an OR relationship Trigger type LIN Synch break CAN LIN triggers Event interval e Analysis functions No of analyzable frames 3 000 max Analysis results display Waveform and analysis list display detailed analysis list display decode display CAN analysis display ite
15. r not the acquired waveform passes through the specified area Zone types RECT Polygon WAVE GO NOGO parameter Determines whether or not the specified parameter of the acquired waveform is within the specified range Param Choose Measure FFT or XY GO NOGO telecom test Performs judgment using the conditions specified in the telecom test ANALYSIS Selectable from XY FFT Wave Parameter Accum Histogram and Serial Bus X Y displays XY1 XY2 and T Y simultaneously FFT supports up to 250 k points FFT Wave parameter Single wave parameters can be viewed in one of the following formats Histogram Trend and List A histogram of the selected area can be displayed for a continuous signal Serial bus 1C SPI and CAN buses can be analyzed and the analysis results displayed optional Accum histogram I C Bus Analysis Functions optional eApplicable bus C bus Bus speed Max 3 4 Mbit s Address mode 7 bit 10 bit SM bus complies with System Management bus e Trigger function standard Source SCL CH1 to CH4 SDA CH1 to CH4 Type Selectable from the following five options Address amp data trigger on combination of assigned address amp data pattern Non Ack trigger on non acknowledge condition Every start trigger on start condition General call trigger on general call and the following byte Start byte HS mode trigger on Start byte and HS mode eAnalysis function Signal input CH1 to CH4 M1 to M
16. rinter Battery backup Setup data and clock are backed up by an internal lithium battery Battery life Approximately 5 years at an ambient temperature of 25 C Operating temperature range 5 40 C 1 Measured value under standard operating conditions after a 30 minute warm up followed by calibration Standard operating conditions Ambient temperature 23 5 C Ambient humidity 55 10 Error in supply voltage and frequency Within 1 of rating 2 Value in the case of a repetitive signal The frequency bandwidth of a single shot phenomenon is the smaller of the two values DC to sampling frequency 2 5 or the frequency bandwidth of the repetitive phenomenon 3 When the input section is shorted the acquisition mode is set to normal the interleave mode is OFF accumulation is OFF and the probe attenuation is set to 1 1 4 Typical value denotes a representative or average value and is not strictly guaranteed 5 The parallel acquisition architecture of the DL9000 series ensures no decrease in acquisition rate for multi channel use External Dimensions Common to All Models Unit mm 0 0 ooo0o 0 occo Sp esses ooo0od ae aleele http www yokogawa com tm DL9000 Power Supply Analysis and User Defined Math Function Specific
17. time T1 T2 Time accuracy Event types Enhanced 0 2 div 10 of trigger level 50 mV 10 of trigger level DL9040 DL9040L DL9140 DL9140L DL9240 DL9240L DC to 500 MHz DC to 1 GHz DC to 1 GHz DC to 100 MHz DC to 100 MHz DC to 100 MHz DC to 50 MHz DC to 50 MHz DC to 50 MHz Trigger occurs on the edge of a single trigger source Trigger occurs on the edge of a single trigger source when Qualification condition is true Trigger occurs on the OR logic of the edge conditions set to multiple trigger sources Trigger occurs on ENTER EXIT when the state condition is true Trigger occurs on a width of a single trigger source Trigger occurs on a width of a single trigger source when Qualification condition is true Trigger occurs on a width when the state condition is true Trigger occurs upon change in condition when the condition remains true longer than time T1 Trigger occurs upon change in condition when the condition remains true shorter than time T1 Trigger occurs upon change in condition when the condition remains true longer than time T1 and shorter than time T2 Trigger occurs upon change in condition when the condition remains true shorter than time T1 and longer than time T2 Trigger occurs when the condition is true for duration longer than time T1 1 ns to 10 s 500 ps resolution 0 2 of setting 1 ns Trigger occurs when the event cycle is within the specified time range After Event 1 occurs tr
18. to show the specified waveform eAnalysis result save function Storage of analysis list data The data can be saved to CSV format files CAN Bus Analysis Functions optional eApplicable bus CAN version 2 0 A B High speed CAN ISO11898 Low speed CAN ISO11519 2 eBit rate 1 Mbps 500 kbps 500 kbps 250 kbps 125 kbps 83 3 kbps user defined e Trigger function standard Source CH1 to CH4 Input through differential probe Type SOF trigger Frame ID trigger Data field trigger Selectable up to 8 bytes Remote Frame trigger Error Frame trigger Ack trigger Frame ID Data OR trigger Specify up to four ID Data or Ack trigger conditions to set triggers on a logical OR condition Event Interval trigger eAnalysis function Analyzable number of frames 3 000 max Analysis result display Waveform and analysis list display Detailed analysis list display Analysis display items Frame type time from trigger point frame ID DLC Data CRC presence absence of ACK eAnalysis support functions Data search Field jump Stuff bit calculation eAnalysis result save function Storage of analysis list data The data can be saved to CSV format files Built in Printer B5 Option Printing method Thermal line dot Paper width 112 mm Effective print width 104 mm 832 dots Auxiliary I O Section Rear panel I O signal Ext trigger input ext trigger output trigger comparator output GO NO GO I O video output

Download Pdf Manuals

image

Related Search

Related Contents

2006-Present User Instruction Manual (RED) Autoglide Operator  BOB MA0607 User's Manual  D6200 WiFi DSL Modem Router User Manual  Lithium-ion cordless drill/driver EN Lithium-lonen-Akku  User Manual - Home Depot  AT1 USER MANUAL - Lime Technologies  ML610Q359/ML610Q360 Reference Board User`s Manual  GE JGRP16 User's Manual  Pregao1215 - Justiça Federal  tiptel  