1. EOUIN X www prolight co uk POWER rL WER Order code EQLED77 IMPACT rL WER Order code EQLED79 User manual Equinox Power Flower amp Impact Flower Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Equinox Power Flower amp Impact Flower Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular cauti
2. 100 or 100 The user can adjust the gobo wheel to the correct position via this option if the image of the gobo is partially obscured noka Review the motor reset status If the LED display shows f r f then the gobo wheel motors position is incorrect If the LED display shows f ot then the gobo wheel motor has reset successfully If the LED display shows r r then the rotation wheel motors position is incorrect If the LED display shows r aot then the rotation wheel motor has reset successfully r 5k Resets the unit to its factory settings To exit out of the above press the MODE button until you are back at the main menu Total reset In addition if the fixture is not operating properly after powering on and menu is not operating normally press the MODE and ENTER buttons at the same time then power on until the LED display flashes then release the buttons Note This will also restore the factory settings Equinox Power Flower amp Impact Flower DMX set up DMX Control Mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or mor
3. a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks LED failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Equinox Power Flower amp Impact Flower Technical specifications You should find inside the carton the following items 1 Fixture 2 Power cable Technical Specifications EQLED77 Power Flower DMX channels 1 3 or 5 selectable Sound activated auto DMX and master slave e 1 x 20W white COB LED e Multicolour reflector dish and 11 gobos 4 Push button LED digital display 0 100 dimming and variable strobe via DMX e IEC Power in out sockets 3 pin XLR in out sockets Power consumption 45W Power supply 100 240V 50 60Hz Dimensions 232 x 281 x 260mm 195mm with bracket folded e Weight 4 3kg 3 User manual EQLED79 Impact Flower e DMX channels 1 3 or 5 selectable e Sound activated auto DMX and master slave e 1x 20W white COB LED e 11 solid colour gobos with mirror dish e 4 Push button LED digital display e 0 100 dimming and variable strobe via DMX e IEC Power in out soc
4. address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation The Equinox Power Flower can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2m CABLI11 5m CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split 10 Equinox Power Flower amp Impact Flower DMX set up Notice e Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 in 3 pin XLR DMX 512 out 3 pin XLR gt ow bbbnbnpnnnmphr mr rm XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground O Pin 2 Negative FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a e D
5. MX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 3 pin CABL89 5 pin will decrease the possibilities of erratic behaviour 5 pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion 3 Pin XLR socket Pin 1 GND seteen Pin 2 Signal Pin 3 Signal 2 a 5 Pin XLR socket 3 Pin XLR socket Pin 1 GND screen Pin 1 GND screen Pin 2 ignal Pin 2 Signal gt Pin 3 Signal Pin 3 Signal Pin 4 Pin 5 N C Correct Disposal of this Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries with seperate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please seperate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their lo
6. cal government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal EQUIN XX www prolight co uk
7. de press the MODE button to show roHE on the rear of the unit Now press the ENTER button and use the UP and DOWN buttons to choose one of the 4 settings rar G Static mirror dish r cu Spins the mirror dish in a clockwise direction In this menu press the ENTER enter the rotating speed settings through the UP or DOWN to select the speed with 10 increments r c cu Spins the mirror dish in a anti clockwise direction In this menu press the ENTER enter the rotating speed settings through UP or DOWN to select the speed with 10 increments r Pro Spins the mirror dish clockwise and anti clockwise whilst running the built in programs Press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button LED setting options While in the auto mode press the MODE button to show Pd on the rear of the unit Now press the ENTER button and use the UP and DOWN buttons to choose one of the 2 settings by pressing the ENTER button and using the UP and DOWN buttons accordingly and press the ENTER button to confirm the setting P c an Set the brightness of the LED from 000 255 000 off 255 full on In this menu press the ENTER button through the UP or DOWN to set the chosen brightness PPro Sets the led into fade in and fade mode Fade speed can be set
8. e channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to
9. from 00 15 00 slow 15 fast In this menu press the ENTER button through the UP or DOWN to set the chosen fade speed Press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button Note After completing your settings the auto run mode will run according to your settings Built in programs mode To access the built in programs mode press the MODE button on the rear of the unit to show Pra onthe LED display Now press the ENTER button and use the UP and DOWN buttons to select between the program options Pra I This program is set to a slow rotation with fade in and fade out Prac This program is set to a fast rotation with fade in and fade out Press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button Equinox Power Flower amp Impact Flower Operation Modes Factory reset menu mode Error reset Note you only need to go into this mode if the rear of the unit shows Err on the LED display on start up To access the setting mode press the MODE button on the rear of the unit to show SFE on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 3 settings by pressing the ENTER button and using the UP and DOWN buttons accordingly r 8 Set the offset of the gobo wheel from 0
10. ions press the MODE button 6 Equinox Power Flower amp Impact Flower Operation Modes Auto run mode To access the auto run mode press the MODE button to show AL 1li on the rear of the unit In the auto run mode there are three setting options to choose from Gaba Gobo setting options r uk Gobo rotation options Pd LED setting options Gobo setting options While in the auto mode press the MODE button to show Laba on the rear of the unit Now press the ENTER button and use the UP and DOWN buttons to choose one of the 5 options Gar L Static gobo L c u Spins the gobo wheel in a clockwise direction In this menu press the ENTER button then us the UP or DOWN buttons to select the speed Gec u Spins the gobo wheel in a anti clockwise direction In this menu press the ENTER button then us the UP or DOWN buttons to select the speed l P c Gobo selector In this menu press the ENTER button and then use the up and down buttons to scroll through the 11 static gobos L F r o Spins the gobo wheel clock wise and anti clock wise To exit out of any of the above options press the MODE button Pattern number 1 2 3 oO pi BEZ EZ EW BIWI S O Ales N Equinox Power Flower amp Impact Flower Operation Modes Mirror dish rotation options While in the auto mo
11. kets 3 pin XLR in out sockets Power consumption 45W Power supply 100 240V 50 60Hz Dimensions 232 x 281 x 260mm 195mm with bracket folded e Weight 4 3kg Overview 4 QO 6 O DMX IN 9 9 9 MODE ENTER 6 E QUl 55 gt i O 7 DMX OUT O Identification O Hanging bracket W Earth point Safety eye 5 LED display Function buttons DMX input socket DMX output socket IEC power in socket IEC power out socket 10 Hanging bracket tightening knobs 11 Fuse 1A 240V 9 N 9 91B N 2 POWERI A LIS WER www prolight co uk Ji ZHOSA A0 Z 001 ZHOS 09 AOPZ AOL aMOd LNO YAMOA Equinox Power Flower amp Impact Flower Operation Modes Operation modes DMX mode To access the DMX mode press the MODE button on the rear of the unit to show 5 IZ on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the desired DMX address from dU i d5 IZ and press the ENTER button to confirm the setting DMX channel mode To access the DMX channel mode press the MODE button on the rear of the unit to show 5 Ig on the LED display Then press the ENTER button and use the UP and DOWN buttons to set the desired DMX address from dU O i d5 i2 Now press the ENTER button to choose one of the 1 3 or 5 DMX channel modes use the UP and DOWN buttons and pres
12. on e Never remove warning or informative labels from the equipment e Do not open the equipment and do not modify the equipment e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors e Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 100V 240V Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by
13. s the ENTER button to confirm the setting 1 channel DMX chart channel vae maton Show Program 3 Slow motion mode Mirror dish 360 degree rotation 180 214 Mirror dish clockwise rotation 215 255 Mirror dish anti clockwise rotation 0 255 LED brightness 0 100 1 2 3 _ Equinox Power Flower amp Impact Flower Operation Modes 5 channel DMX chart onan we Foto Gobo wheel anti clockwise rotation Mirror dish 360 degree rotation Mirror dish clockwise rotation Mirror dish anti clockwise rotation No function Sound active No function Strobe slow to fast When in sound active 0 255 sensitivity To exit out of any of the above options press the MODE button Master slave mode To access the master slave mode press the MODE button on the rear of the unit to show SL Aw on the LED display and press the ENTER button to confirm the setting The unit will now run in sequence with the master unit Please ensure that all slave units are set to the same DMX channel mode as the master unit Sound active mode To access the sound active mode press the MODE button on the rear of the unit to show Lifid on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sound sensitivity level from SLiUGU Sj and press the ENTER button to confirm the setting Note SU00 Low SU31 High To exit out of any of the above opt