Home
Two platforms, one system: MasterBus / CZone™
Contents
1. Banking caps NMEA2000 network Male cap Product code 80 91 1 0050 00 Female cap Product code 80 91 1 005 1 00 Power cable INMEA2000 network e mtr 3 2 ft Product code 80 91 0028 00 Terminating resistors NMEA2000 network Product code 80 911 0030 00 female 80 911 0031 00 male 90 Elbow connector NMEA2000 network Product code 80 91 0046 00 Cable glands For SCI silicon Product code 80 91 0035 00 SI blk silicon Product code 80 91 0036 00 MI blk silicon Product code 80 9 1 1 0033 00 Terminal blocks SI MI 8 way Product code 80 91 0043 00 OI MOI 6 way Product code 80 91 1 0041 00 For MI 6 way Product code 80 91 1 0042 00 Seal boot For OI MOI 6 wire blk silicon Product code 80 91 0034 00 accessories Through bulkhead adaptor NMEA2000 network Product code 80 91 0052 00 Female field serviceable connector NMEA2000 network Product code 80 91 0053 00 Male field serviceable connector NMEA2000 network Product code 80 91 0054 00 Hole plugs Product code 80 91 1 001 6 00 3 2 mm for MI and SI cable glands 80 911 0017 00 5 mm for SCI cable glands DC current shunt 450A 50mV shunt supplied with 80 600 002 1 00 Dim 83x45x44 mm 3 25 x2 8 x2 75 Product code LB 450 50 CZone wireless remote kit Simple to set up wireless remote control
2. Product code Dimensions hxwxd Weight Battery voltage Current MasterBus powering Standard fuses Spare fuse Alarm Protection degree Delivered with DC Distribution 500 The DC Distribution 500 is the smallest distribution model available It connects up to four DC devices to the DC groups such as a battery charger inverter alternators and solar panels An included plug amp play cable makes connection to the MasterBus network a breeze The MasterView panel gives all fuses logical names referring for instance to the connected equipment to ensure you receive understandable error notifications f ex charger fuse defect 77020100 150x150x65 mm 5 9x5 9x2 5 inch kg 2 2 Ibs gel AGM wet Lithium lon spiral 12 24 or 48 V DC 300 A continuous 500 A for 5 minutes yes 500 A T fuse 300 A continuous at 40 C alarm timers auto start stop for the generator warning low voltage warning low state of charge high voltage IP21 MasterShunt temperature sensor MasterBus Terminator MasterBus cable isolation cover for DC connections BESS ee i 77020200 150x216x65 mm 5 9x7 9x2 5 inch 2 kg 2 6 Ibs 12 24 of 48 V DC 300 A continuous 500 A for 5 minutes no 80 80 125 160 A ANL type deviating values can be ordered separately 125 AANL type fuse monitoring IP21 5 fuses hex tool MasterBus Terminator MasterBu
3. Mastervolt comes in Mastervolt s latest innovation requires fewer cables takes up less space and increases luxury Digital DC 10 10 As the pinnacle of system intelligence the Digital DC IOx10A has ten output channels of 10 A for all functions including lighting pumps or electronics The system also includes several intelligent alarm functions and luxury options such as follow me home light stays on for a specific time after you leave the yacht and the standard option of requesting your battery status by text message Other examples of standard options include delayed dimming of lights or overload warning signals By using less material and thinner cables Mastervolt s digital distribution saves considerable time and costs for installation And because system integration and system management are built in as standard you are assured of an optimal balance between energy generation storage and consumption If required the generator will start automatically when you turn on the air conditioning Dimming the lights is no longer a complex operation as the Digital DC 10 10 makes dimmers obsolete Product code 77020400 D pila MasterBus powering yes Power consumption lt 2 mA at 12 24V s f Protection degree IP21 Dimensions hxwxd 40x229x1l 10 mm 1 56 9 4 34 inch Weight 750 gr 1 7 165 DC OUTPUT Connection cable max 4 mm Max software fuse current 10 A per channel Hardware fuse current 15 A per channel DC
4. SCI switches can control single Ol channel Output for backlighting of switch labels dimmable Outputs systems on and function fault codes to systems on LED of switches dimmable Dimensions wxhxd 156x100x42 mm 6 3 32 x3 29 32 x 5 8 PX5 water ingress protection Programmable switch types 8 Inputs per module 16 individual controls Sequential button press functionality Signal Interface The Signal Interface SI connects the CZone system to your external sensors alarms and switching devices The SI allows intelligent automated operation of circuits depending on the state of the input Accepts inputs from traditional switch types being used to control outputs Accepts inputs from switches to trigger alarm i e high water float switch Accepts inputs from industry standard tank senders 0 5V 10 180 Ohm 240 33 Ohm Accepts inputs from general voltaic or resistive signals can be used for controlling outputs or to display a physical position i e show a hatch is partially open LED status indicators for each input e Dimensions wxhxd 156 100 42 mm 6 3 32 x3 29 32 x1 5 8 Outputs standard NMEA2000 sentences e Voltage sensing input range 0 34 V DC PX5 water ingress protection e Resistive input range 0 1000 Ohms Meter Interface The Meter Interface MI accepts inputs from external AC and DC power metering sensors such as AC and DC voltage and amps AC kWatts and DC battery capacity in amp hours
5. easy to install configure and operate the digital control system with pre wired components for quick connections But you still have a customizable solution to suit unique installation and application needs including night running or at anchor as well as control at multiple locations It has eight outputs up to 50 A each supports multiple pole designs and two separate buss feeds To make it easy status LEDs and manual bypass are located right at the enclosure 8 Outputs at up to 50 amps each Provides circuit protection and control Circuit status and run current displayed for each circuit Status LED s at enclosure Customizable to suit installation requirements Manual bypass at enclosure Pre wired for quick connection Provision for MCB RCD s Staggered start up of loads Timers 10 V 240 V 110 220 V 50 or 60 Hertz Supports multiple pole designs i e double triple four pole PX5 enclosure Utilizes standard DIN rail mounted components for circuit protection and control Can support two separate buss feeds i e 2 load groups in one box Delay before circuits come on to allow generators to come up to speed e Dimensions hxwxd 295x458x130 mm 11 61 x18 x5 enclosure dimensions may change depending on installation requirements AC Mains Interface ACMI A sophisticated source selector or transfer switch the AC Mains Interface enables the user to specify which AC power source is actively
6. supplying power to the ship generator inverter shore power It was developed for use with the CZone digital control system but may also be used a stand alone device The ACMI can be programmed to automatically change the supply source when the current rating is exceeded and includes a manual bypass and user friendly display screen that ensures easy current voltage frequency and power monitoring Other features include six monitored over current protected main power inputs of up to 100 A each as well as two outputs which enables two separate load groups and a parallel option for use with a single source To simplify installation the ACMI comes pre wired for easy installation 6 Source inputs up to 100 A eg 2x shore power 2x generator Auto changeover Monitoring of channel status on off fault Provision for RCD s Provides circuit protection and control Load shedding Manual override at enclosure and via remote panel Status LED s at enclosure Customizable to suit installation requirements Pre wired for quick connection Supports multiple pole designs i e double triple four pole Timer controls e 10 V 240 V 110 220 V e 50 or 60 Hertz e IPX5 enclosure Utilizes standard DIN rail mounted components for circuit protection and control Physical and software lockouts between source controls prevents two sources from becoming connected Reverse polarity and bad power supply alarms including auto disconnec
7. the battery supply these modules look for sudden increases in voltage then switch into protection mode to absorb and suppress the high energy spike Product code 80 707 00004 00 12 V DC 80 707 00005 00 24 V DC Fully integrated C20 CZone MasterBus Bridge Interface M NAL NMEA2000 network e LopJJ SER E DC loads 6x 20A D Ultrasonic tank sender IO Touch screen Switch cluster Meter Interface Signal Interface Output Interface O O 00 Switch Control Interface Battery distribution panel NMEA T connector CZone MasterBus Bridge Interface The CZone MasterBus Bridge Interface physically connects the MasterBus and CZone networks allowing you to pick and choose the best products for your application The two networks will communicate and act as one providing seamless control and monitoring of devices on both networks from either MasterBus or CZone displays AC loads DC loads DC loads Shore power Mass Combi a DC loads Mass Gl isolation transformer MasterView System MasterShunt DC Distribution Digital DC 10x10 Lithium lon 12 V service battery Digital DC 10x10 Advantages of one system Fewer cables Less weight Installation time savings Increased flexibility in terms of design changes e Super Yacht power and load management capabilities Remotely accessible e Easy to maintain Integr
8. 0 yes 66x78x32 mm 90 gr IP21 MasterBus cable MasterBus Terminator user s manual 2 6 x3 1 x1 3 0 20 Ibs 77030450 no 66x78x32 mm 80 gr IP21 Interface connection cable MasterBus cable WA KE SE 0 18 Ibs MasterBus Terminator user s manual 77031000 no 66x78x32 mm 80 gr IP21 GPRS antenna MasterBus cable MasterBus Terminator 2 6 x3 1 x1 3 0 18 Ibs user s manual SIM card not included 77031300 no 54x86x58 mm 35 gr IP2 MasterBus Terminator user s manual 2 x3 4 x2 3 0 08 Ibs switches and mounting frame not included incl mounting frame incl MasterBus Terminator 7703 1400 no 56x120x65 mm 45 gr IP2 MasterBus Terminator user s manual Pg UT 7 2 6 0 1 165 switches and mounting frame not included incl mounting frame incl MasterBus Terminator 77031800 no 66x78x32 mm 100 gr IP21 NMEA connection cable MasterBus cable 2 6 3 1 1 3 0 22 Ibs MasterBus Terminator user s manual 77030900 no 66x78x32 mm 80 gr IP21 cable with plug MasterBus cable 2 6 3 1 1 3 0 18 Ibs MasterBus Terminator user s manual 77031500 no 66x78x32 mm 80 gr IP21 MasterBus cable MasterBus Terminator user s manual 2 9X3 T 35 0 18 Ibs 77030500 no 66x78x32 mm 80 gr IP21 MasterBus cable MasterBus Terminator user s manual x49 0 18 Ibs 77030300 no 66x78x32 mm 80 gr IP21 MasterBus cable MasterBus Terminator user s manual 2 68X3 PXI 34 0 18 Ibs 80 9 1 0072 00 no 69x69x50 mm 145 gr IP65 MasterBus
9. 00 Connect the MasterView System or your PC with the MasterBus network Provides the power and software license key for the MasterView System panel Deliverd as a standard with MasterView System also separately available MasterView System Interactive touchscreen The MasterView System full colour graphical display provides a single point for controlling monitoring and configuring onboard electrical systems A customisable easy to read display simplifies operation for the boat user while providing the installer with the ability to configure the system without the use of a PC Home screen The home screen provides a status overview of power sources like shore connections inverters generators and batteries A basic form of control is possible for example turning on and off your inverter Digital switching screen This screen shows the layout of your yacht lights and selected pumps You manage the loads by clicking the icons The background image can be uploaded for full customisation Alarm notifications are shown via eye catching pop ups System overview This screen gives a dynamic graphical overview of your electric system answering any questions you have in an instant Incorrect line voltages are shown in red inactive circuits in grey It couldn t be easier Tank level screen Stop guessing and know immediately the contents of up to 20 tanks You can also install your own warning signals for full or nearl
10. 40300 25 m product code 77042500 6 product code 77040600 100 m product code 77045000 MasterBus Terminator product code 77040000 MasterBus DIY kit product code 77050000 Cut your own cables to length and finish comprising e Professional RJ45 crimping tool e 50x MasterBus RJ45 connectors e 50x green MasterBus RJ45 protection boots 100 m green MasterBus CAT5E UTP cable Separately available e 25x MasterBus RJ45 connectors 8 pole product code 77040010 e 25x green isolation caps for RJ45 connector product code 77040015 SETS Po AP teen om UP Sev QW tA CY Nc m a intelligent simplicity of MasterBus MasterBus makes life easier for designers builders and installers of power systems This brilliantly simple platform for communication and connections ensures that all components speak the same language One communication protocol with high speed CANbus technology The optimum integration of power conversion and power storage also includes digital switching Control your system centrally or switch on a bunk light locally all via MasterBus The one bus approach even allows control from your home MasterBus helps realise an electrical system that combines remarkably easy installation with ultimate reliability no matter how large or complex your system Fewer cables It all starts with MasterBus a brilliantly simple one cable system for a
11. Buttons are configurable for momentary on or latching control of circuits 80 m 250 ft operating range Rolling code Product code 80 91 1 0045 00 USB CAN adapter Connects PC to CZone network for configuration and system set up Product code 80 91 1 0044 00 Cable assembly SCI to suit switches above Product code 80 911 0018 00 5 meter 80 911 0019 00 meter 80 911 0020 00 2 meter 80 911 0021 00 3 meter 80 911 0022 00 4 meter 80 911 0023 00 5 meter AC transducer Includes 3 voltage transformers for up to 3 voltage inputs Dim 69x140x50 mm 75 x5 5 x2 Product code ac vsen 4 Push buttons For use with CZone systems only Momentary and latched actuation options available Blue and red circuit status indication LED options 9 mm mounting hole IP67 environmental protection e Stainless steel components Product code 80 911 0060 00 momentary ON OFF red LED 80 91 1 0063 00 momentary ON OFF red LED 80 91 1 0062 00 momentary ON OFF blue LED 80 91 1 0061 00 momentary ON OFF blue LED Custom switches Red or blue systems in operation and backlighting LED s Product code 80 91 1 0037 00 ON OFF red LED 80 91 1 0038 00 mom ON OFF red LED 80 91 1 0039 00 ON OFF ON red LED 80 91 1 0040 00 mom ON OFF mom ON red LED 80 91 1 0066 00 mom ON OFF blue LED 80 911 0071 00 ON OFF mom ON blue LED Current transformer Max current 150 A AC One CT 10 3 cur
12. D i x WE Yy a B ff y i r ri i ve Wii i Digital switching the future is now By de centralizing your installation it is possible to create smarter systems with less cables and installation work Central switchboards are replaced by de centralized power outputs which are controlled via a bus system These outputs power equipment like lights pumps and navigation equipment Different input modules can be connected to this bus as well These input modules from switches to touch screen panels control the output modules This way you can control your yacht from anywhere even from your mobile phone via text messages With digital switching systems you have greater flexibility and more intelligence to be integrated Without additional components like relays timer modules and extensive cable trees it is possible to design a smart system Digital switching systems result in systems that are easy to operate Two platforms available MasterBus and 2 MasterBus is based on a proprietary CANbus based network used by most Mastervolt products This platform is perfectly suited for integration of digital switching with power electronics from Mastervolt The CZone digital control and monitoring system is an open platform and based on NMEA2000 platform It will work both as a standalone system or in conjunction with NMEA2000 compa
13. INPUT Connections max 95 mm or directly connected to MasterShunt or DC Distribution Maximum current 100 A Supply voltage 8 30 VDC MasterView control panels Everything under control Fast and clear information about your onboard electrical system is vital to relaxed boating Usually a number of multiple panels are required to read the details of an expansive electrical system and the interpretation of these panels and how they relate to one another is left to the user Mastervolt puts an end to this undesirable situation with its intelligent MasterView panels gt E BS Multifunctional control panel MasterView Easy This multifunctional touchscreen display can monitor every MasterBus and CZone product Connected via the MasterShunt the display functions as a battery monitor and is connected to the generator as a generator panel The favourites screen can be custom designed to meet your specific needs for information and control The smartest solution MasterView System Say goodbye to cluttered unclear and excessive information with Mastervolt s intelligent MasterView System based on in house developed software combined with a user friendly 0 4 inch colour touchscreen The simple yet brilliant set up of the MasterView System intelligently connects all the power sources and loads generator charger bilge pump engine lighting air conditioning etc via the MasterBus It provides all the info
14. and 96 remaining All with user definable high and low alarms AC 3x AC voltage inputs multi voltage e 2 x AC current inputs Calculates true RMS power DC 3x DC voltage inputs multi voltage 2 x DC current inputs Calculates battery capacity as ampere hours and percentage charge remaining Resolution for current metering down to 0 1 A GENERAL Dimensions wxhxd 156x100x42 mm 6 3 32 x3 29 32 x 5 8 PX5 water ingress protection Outputs standard NMEA2000 power monitoring sentences Output Interface The Output Interface Ol provides an intelligent replacement for traditional circuit breaker and fuse panels It has 6x high power robust output channels which provide the power supply control and fusing for a circuit as well as integrating many other built in features such as timers and dimmers Connection to the unit is simple a large 6 way plug allows connections to cables of up to 16 mm 6AWG in size or multiple smaller conductors No need for specialized crimp terminals and expensive crimp tools to be carried for terminations to CZone just a blade screwdriver A protective flexible boot offers protection to the connections from harsh environment conditions 4 levels of backup fusing including manual override as required by ABYC Multiple channels can be bridged together to offer higher current switching Power consumption 12 V 85 mA standby 60 mA Motor Output Interface The Mo
15. ated solution Single button mode selection e Redundant and safe e Global service network MASTERVOLT AUTOMOTIVE Latest News M Hause Proto The ultimate comfort of RE wit various ey Sree wearing secret Mani writ 171 aii Ma MEF Aarne cote gwna by an haa coa of iha largesi 1 MHE inital leis cable lat of features Dealer Locator Downloads For more information on MasterBus see www mastervolt com For more information on CZone see www bepmarine com EMEA APAC AMERICAS Mastervolt BV BEP Marine Actuant Electrical Snijdersbergweg 93 1105 AN Amsterdam ZO The Netherlands T 31 0 20 34 22 100 F 31 0 20 34 22 169 info mastervolt com MP STERVOCT 55 Paul Matthews Road Albany Auckland 0632 New Zealand T 64 0 9 41 57 261 F 64 0 9 41 59 327 enquiries bepmarine com Actuant COMPANY N85 W12545 Westbrook Crossing Menomonee Falls WI 53051 U S A T 1 800 307 67 02 F 1 800 799 37 79 infoNA mastervolt com Version no 1211 12EN Article no 500007530 2012 Mastervolt All rights reserved www mastervolt com
16. cable adapter MasterBus Terminator 2 EDE X 0 32 Ibs user s manual 77031200 no 80x181x28 mm 530 gr IP65 MasterBus cable MasterBus Terminator BS aT 1 17 Ibs current transformer 00 5 user s manual 77031900 yes when the PC 91 185 33 mm 750 gr IP65 USB cable SPC cable MasterBus cable is switched on A6 X78 X10 1 65 Ibs MasterBus Terminator user s manual Replacement fuses and other amps product code 77049040 40 A 77049050 50A 7049060 60A 77049080 80A MasterShunt fuses DC Distribution fuses 77049100 100A The robust fuse 500 A 160 V DC The DC Distribution 77049125 125A 50 kA short circuit current is standardly comes with TOL suitable for high short circuit four ANL fuses 80 80 currents from the batteries 125 and 160 A and a m m Spare fuse available separately spare fuse of 125 A 77049300 300 A product code 77049000 77049400 400 A Practical MasterBus accessories MasterBus communication cable Suitable for data traffic and powering peripheral equipment this is the only cable you need for your MasterBus network MasterBus compatible products come standard with two ports while other equipment requires an interface A DIY kit is optional Available cable lengths 0 2 m product code 77040020 0 m product code 77041000 0 5 m product code 77040050 15 m product code 77041500 m product code 77040100 e 20 m product code 77042000 3 m product code770
17. e boat for a day at sea and control of the batteries and m battery charger from a CZone Thanks to galvanic isolation nearly all devices can supply power to the MasterBus ensuring a safe and stable network The wide display or other compatible range of interfaces and modules allows you to connect any equipment you wish to your MasterBus network and manage marine navigation screens from monitor or operate it locally centrally or even from your home d Simrad B amp G Professional perspective The MasterBus and CZone network makes life easier for designers builders and installers of power systems with less material less work less fuss and an easy testing method Moreover the MasterBus network is available in ten languages Both systems provide a range of displays for controlling and monitoring on board systems such as inverters chargers circuits power and tank levels The range of displays offer a consistent intuitive user interface Digital switching makes your life easier More information Contact your nearest dealer or see www mastervolt com or www bepmarine com intelligent logic of digital distribution As owners demand ever higher levels of onboard luxury and comfort yachts need to carry more equipment which in turn takes up more space This makes it all the more essential to intelligently install equipment in the available space and that is where digital distribution by
18. ee User can open pumps group and select fresh water pump This m screen also allows the user to monitor the status of the circuit ened Harm uml i e on off fault and current draw Settings Allows OEM or technician access to the configuration via password of a system No need for computer to set or change configuration settings such as circuit labels circuit breaker sizes etc DI only Modes Key to the ease of operation With one key press the user can turn on a group of circuits without having to scroll search for and turn on the individual circuits that they need for operation of their vessel vehicle When leaving simply press systems off to turn off all non essential circuits Entertainment mode allows preset activation of salon lights music etc All functions can be controlled remotely CZone Integration Partners Simrad and B amp G have added CZone control and monitoring to their award winning fully networked chartplotter multifunction displays View CZone monitoring data tank levels battery voltage alongside radar fish finder video and chartplotter information or navigate to the CZone page to operate any circuit from the intuitive control page AC Interfaces AC Output Interface ACOI Searching for a simplified way to network monitor and control onboard AC circuits The AC Output Interface does it all and provides circuit protection for all onboard AC devices It is
19. els Logging of minimum battery capacity level AC power meter Displays multiple line voltages 230 and 120 V includes high and low voltage alarm Displays AC line frequencies includes high and low frequency alarm and AC power consumption in kW Logging of minimum and maximum voltage and frequency levels Logging of maximum AC current Tank levels View tank level information for multiple tanks and fluid types Data Displays standard NMEA2000 information Displays temperature and pressure values Alarms diagnostics Logging of circuit run time and on cycles CZone network status reporting Presents alarms for on board faults in audible and visual form bilge pump running smoke alarm LCD displays The CZone displays are designed with both the manufacturer and end user in mind The easy to use display screens put the control of all components directly at your fingertips Multiple display interfaces can be used in the same system The scroll and click interface is simple to use in the roughest of seas or bumpiest of roads se Monitoring Allows user to easily monitor AC and DC power tanks data He alarms and circuit status Presents data in analog and digital form mem raa ee gt Control a i Breaks down the circuits into easy to identify groups for quick Poe E control i e to turn on fresh water pump open pumps group
20. g functions with other NMEA2000 compliant screens Ys The CZone MasterBus Bridge Interface expands the level of systems UY integration to a whole new level No other company can bring digital switching power electronics and marine navigation systems together into one interactive seamless system Versatility amp security The CZone system designed for 9 32 V systems features built in timers dimmers including support for halogen lighting alarms voltage reducers and load shedding With safety in mind the CZone system features a manual bypass Our No Single Failure Point technology gt ensures a plug amp play system that is designed to handle mishaps If module is damaged the system will automatically program the replacement module when it is plugged in This means any module gt can be replaced without using high tech service people Our security features allow custom configurations that can be locked LCD displays The CZone displays are the interface between the CZone and MasterBus networks and the user They offer full control of circuits as well as the ability to view important onboard system information such as tank levels and power levels for both AC and DC supplies they also provide audible and visual alarms with systems diagnostics The displays are extremely intuitive to use with simple controls and a menu structure that is easy to follow The modes of operation feature allows the control
21. ll communication between the various products With MasterBus you need far fewer cables and all your system components will speak the same language Reap the benefits of a single communication protocol with high speed CANbus technology that is fast reliable flexible and expandable Easy maintenance Replacing a component can often lead to complex configuration problems Not with Mastervolt The MasterBus network recognises any replacement directly and automatically asks whether you want to keep the same or change your configuration You stay well informed and with everything under control For more information see MasterShunt 500 This ultra modern battery monitor provides detailed information on the status of your batteries including voltage current remaining time and used capacity in percentages With an intelligent connection system the MasterShunt is easily connected to the DC distribution The integrated system clock combined with command based events custom automates your system to your needs Example of system automation The generator should start automatically when the batteries are almost depleted The MasterShunt also provides a robust built in main fuse that can safely interrupt short circuit currents of 50 000 Amps Product code Dimensions hxwxd Weight Battery types Battery voltage Current MasterBus powering Main fuse System functionality Programmable alarms Protection degree Delivered with
22. of multiple circuits with a single push of a button For instance night running mode turns pre selected lights on to dim levels These modes are all user configurable The CZone displays can be used to set the CZone system parameters for initial installation and future system maintenance DI only Screen size 3 5 transflective QVGA Protection IpX7 water ingress Dimensions wxhxd 105x165x62 mm All A4 4 e Display Interface w power cable black bezel product code 80 91 1 0001 00 3 5 Display Interface e Display Interface w power cable grey bezel product code 80 91 1 0002 00 e Display Interface only black product code 80 91 1 0003 00 e Display Interface only grey product code 80 91 1 0004 00 Product code 80 911 0064 00 Screen size 8 4 SVGA IP Level IP64 Dimensions wxhxd 234x184x42 mm 8 Touch screen Product code 80 911 0065 00 Screen size 10 4 SVGA IP Level IP64 Dimensions wxhxd 276x227x50 7 mm 10 Touch screen Cerne Power Control urn circuits on and off including timer and light dimming control e Set modes of operation Monitoring DC power meter Displays voltages of multiple battery banks includes low and high voltage alarms Displays charge and discharge amps of multiple battery banks Displays battery capacity in ampere hours and 96 charge discharge includes low ampere hour alarm Logging of battery minimum and maximum voltage lev
23. onnects up to four switches to the MasterBus network Standard delivered with connection cables Product code 77031500 Digital AC x6A Digital AC x6A switches all AC loads no matter where they are Loads up to 6 A can be directly switched higher loads should be switched via a relay Product code 77030500 Multipurpose Contact Output Mastervolt s potential free contact can be customised and programmed to give your MasterBus network unprecedented possibilities Use it for example to control a ventilator or operate a generator from a different brand Product code 77030300 MasterBus Tank Level Interface This interface converts analogue sensor input signals to MasterBus data Selectable input signals 4 20 mA 0 300 8 70 V DC Product code 80 91 0072 00 CZone MasterBus Bridge Interface The CZone MasterBus Bridge Interface physically connects the MasterBus and CZone networks allowing you to pick and choose the best products for your application The two networks will communicate and act as one providing seamless control and monitoring of devices on both networks from either MasterBus or CZone displays Functions Control of Mastervolt inverters and chargers from CZone displays and switches Control of MasterBus output devices turn lights pumps etc on off e Control of CZone output devices turn lights pumps etc on off via MasterBus displays and switches Dis
24. play CZone acquired systems information such as tank and power levels on MasterBus displays Display MasterBus acquired systems information such as tank and power levels on CZone displays Transfers alarms between both systems Product code 77031200 AC Power Analyser The MasterBus AC Power Analyser is a multifunctional measuring tool that provides the MasterBus with insight into AC voltage and power frequency Cos Phi and system capacity The device also functions as an inverter control and has a programmable potential free contact Product code 77031900 System Panel Controller Connect the MasterView System or your PC with the MasterBus network Provides the power and software license key for the MasterView System panel Specifications MasterBus Interfaces MasterBus Dimensions Protection Product code powering hxwxd Weight degree Delivered with 77030100 yes when the 66x78x32 mm 80 gr IP21 USB connection cable MasterBus cable is switched on 2 6 x3 1 x1 3 0 18 Ibs MasterBus Terminator user s manual 77030800 no 66x78x32 mm 80 gr IP21 MasterBus cable MasterBus Terminator user s manual Z6 xsa xk3 0 18 Ibs 77030700 no 66x78x32 mm 80 gr IP21 Interface connection cable MasterBus cable 2 6 x3 1 x1 3 0 18 Ibs MasterBus Terminator user s manual 77030475 yes 66x78x32 mm 80 gr IP21 Interface connection cable MasterBus Terminator 2163 0 18 Ibs user s manual 7703110
25. rent transformer is supplied with ACSM If a twin line system is in use a second CT must be ordered Supplied with 80 600 0023 00 Dim 37 5x39 2x13 7 mm 1 5 x1 55 x 55 Hole size 12 mm 0 5 Product code CT 10 3 Heavy duty current transformer Max current 150 A AC CT HD is available for systems with large mains cables too large for CT 10 3 order separately Dim O 47 x 10 5 mm 1 85 x 0 4 Hole size 32 mm 1 25 Product code ct hd CZone MasterBus Bridge Interface The CZone MasterBus Bridge Interface physically connects the MasterBus and CZone networks allowing you to pick and choose the best products for your application The two networks will communicate and act as one providing seamless control and monitoring of devices on both networks from either MasterBus or CZone displays Product code 80 91 1 0072 00 CZone Network Bridge Interface aA For isolating sections of a NMEA2000 network to decrease standby current draw Isolation when bridging between two CAN networks eg connecting CZone to Simrad Simnet For expansion of the NMEA2000 network when the maximum node limit node any device connected to the NMEA2000 network for the network has been reached Once fitted a further 40 nodes can be added Product code 80 91 1 0057 00 Surge protection module Protect your electronics from becoming damaged by harmful high voltage spikes When fitted to
26. rmation you need on your electric system in one clear overview on an organised intuitively operated panel the MasterView System amp MasterView Read out Product code 77010050 Display 7 LEDs Dimensions hxw 60x65 mm 2 4x2x6 inch MasterBus connection yes Powered by MasterBus Power consumption 144 mW Remote panel for reading the IP21 charge status of your charger Weight O onions including error notifications MasterView Read out OEM product code 77010030 If your dashboard is full and does not offer space for a MasterView panel this module allows you to integrate the MasterBus Read out into your own control panel MasterView Easy Product code 77010305 Display 3 5 inch touch screen Dimensions hxw 110x110 mm 4 3x4 3 inch MasterBus connection yes Powered by MasterBus Power consumption 160 mW Protection degree IP2 Weight 230 gr 0 51 165 Languages ENG NL DE SP IT FRA FIN SWE DEN NOR MasterView System Product code 77010400 Display 10 4 inch colour touch screen Dimensions hxw 222x276 mm 8 7x10 8 inch MasterBus connection by means of System Panel Controller delivered as standard Power by means of System Panel Controller delivered as standard Power consumption 28W Protection degree IP64 front Weight 1 4 kg 3 1 Ibs Languages ENG NL DE SP IT FRA FIN SWE DEN NOR System Panel Controller product code 770319
27. s cable isolation cover for DC connections 1 asin I1 zu Bes gt A The CZone digital control amp monitoring network simplifies installation of electrical systems through the replacement of complicated cumbersome wiring to switch and fuse panels with state of the art robust interfaces and light NMEA2000 network cable It also provides a sophisticated solution through the automation of complicated control and monitoring issues associated with today s onboard systems Installation Builders recognize an immediate benefit with reductions in cable usage harness weights and installation times The CZone system also integrates many stand alone components into one intuitive system Wiring is dramatically simplified because the CZone system is designed to remove complex switching clusters and wiring runs Modules can easily be added into the system to best suit the OEM and end users needs Configuration We provide the tools to help you determine the modules needed based on your specific requirements Then simply program with the CZone intuitive configuration tool X A 2 Integration The CZone system is NMEA2000 compliant and uses the standard Micro cables and connectors This also allows a single network backbone to be installed for multiple systems CZone and other 2000 devices Additionally the CZone system can share certain monitorin
28. sterView or PC Product code 77030475 MasterBus Combi Interface This interface integrates a Mastervolt Mass Combi in a MasterBus network and allows it to be operated or monitored via a MasterView panel or PC Product code 77031100 MasterBus Repeater Double the maximum length of your MasterBus network Product code 77030450 MasterBus Serial Interface The MasterBus Serial Interface connects conventional Mastervolt products to the MasterBus Data becomes permanently available to allow configuration operation and monitoring via MasterView panels Product code 77031000 GPRS Module Communicate with your system via mobile phone monitoring current information or operating the system by remote control via a text message or easy shortcuts Product code 77031300 Switch Input 3 PCB Switch Input 3 makes Carling switches suitable for MasterBus and helps you by easily linking various functions to the switch Product code 77031400 Switch Input 4 PCB Switch Input 4 has LED indication for extra information For example The LED will blink when a connected lamp fails For more information see www mastervolt com masterbus interfaces MasterBus network Product code 77031800 MasterBus NMEA2000 Interface The MasterBus NMEA2000 Interface provides the MasterBus network with NMEA2000 information and vice versa Product code 77030900 Digital Input Mastervolt s Digital Input c
29. t and lockouts Current voltage frequency and power monitoring incorporated six channels 2 Outputs load groups allows for two separate load groups with parallel option for use with single source e Dimensions hxwxd 403x630x130 mm 15 8 x24 8 x5 enclosure dimensions may change depending on installation requirements Product code 80 911 0069 00 Product code 80 911 0068 00 lt E 2 ifs Ej Ha iB fiu Kj Ha NE zn a Product code description 80 9 1 001 1 00 Switch Control Interface w seal 80 91 1 001 2 00 Switch Control Interface only Product code description 80 911 001 3 00 Signal Interface w seals connector 80 91 1 001 4 00 Signal Interface only Product code description 80 91 1 0005 00 Meter Interface w seal amp plug 80 91 0006 00 Meter Interface only Note High and low alarm levels can be set for all inputs CZone Interfaces Switch Control Interface The Switch Control Interface SCI provides an interface between the CZone network and traditional mechanical switches that manufacturers and users are familiar with The SCI simplifies your wiring supports your existing choice of switches protects against failures and allows for expanding installation options Single switch position can control multiple Ol channels Attaches to switch panels via custom SCI cable Multiple
30. tible components This allows a fully integrated system including the latest Simrad and B amp G multifunction marine displays chartplotters fishfinder radar autopilot Carrying a high Ingress protection level IPX5 and higher CZone components are ideal for harsh environment installations On the following pages you will find a more detailed description of both digital switching platforms and components The perfect link CZone MasterBus Bridge Interface The CZone MasterBus Bridge Interface physically connects the MasterBus CZone networks allowing you to pick and choose the best products for your application The two networks will communicate and act as one providing seamless control and monitoring of devices on both networks from either MasterBus or CZone displays The MasterBus and CZone network bring features and The popular MasterShunt digital automated functionality normally reserved for superyachts to the everyday boat user CZone and MasterBus networks shunt and ChargeMaster battery provide intelligent automation of complex onboard systems leaving the boat user free to enjoy their boating experience charger will now connect to a NMEA2000 based CZone Customizeable modes of operation allow the boat to be configured to suit the use of the boat at the push of a single network This allows monitoring button the boats systems can be transformed from Dock Mode to Cruise Mode preparing th
31. tor Output Interface MOI has an output pair for controlling DC motors which require a reversal of polarity to change the direction of their mechanical operation For example a DC motor for an electric window mechanism will move the window up or down depending on the polarity of the feed to the motor The MOI also incorporates two standard output channels such as is found on the OI Single motor control and two normal channels per unit 20 A per output Product code description 80 911 0009 00 Output Interface w connector boot 80 911 0010 00 Output Interface only Product code description 80 911 0007 00 Motor Output Interface w connector boot 80 911 0008 00 Motor Output Interface only Fuses for emergency circuit bypass Network status indicator NMEA2000 connector Connector amp protective boot Digital Control Ext cable NMEA2000 network Product code 80 91 1 0026 00 1 6 80 911 0027 00 2 m 6 5 ft 80 911 0024 00 5 m 16 ft 80 911 0025 00 10 m 32 ft Single tee connector NMEA2000 network Product code 80 91 1 0029 00 Power cable for Display Interface e 2 Pin 2 mtr 6 5 ft Product code 80 91 0032 00 Single tee connector with 0 5 mtr 19 5 extension cable NMEA2000 network Product code 80 91 0049 00 2 Way tee connector INMEA2000 network Product code 80 9 0047 00 4 Way tee connector NMEA2000 network Product code 80 91 0048 00
32. y empty tanks All you need to do is connect the MasterBus Tank Level Interface to the network Favourites screen The favourites screen can be custom designed to meet your specific needs for information and control Any information that is available on the MasterBus network is displayed clearly and logically Information can be displayed in various ways on multiple pages for example one overview page one or two breaker pages an engine information page and a NMEA2000 information page For more information see www mastervolt com masterview Operate amp control your Mastervolt offers a wide range of interfaces to connect other systems to your MasterBus network These interfaces ensure a safe and reliable energy system and complete cooperation between all MasterBus products All interfaces can be installed in various ways from DIN rails to surface mounting Product code 7703100 MasterBus USB Interface The MasterBus USB Interface enables you to read and configure the MasterBus network via your PC Product code 77030800 MasterBus Modbus Interface The MasterBus Modbus interface can provide all information from the closed MasterBus network for other monitoring and operating systems by means of the Modbus protocol Product code 77030700 MasterBus Inverter Interface The MasterBus Inverter Interface integrates the Mass Sine inverter in a MasterBus network and allows it to be operated and monitored via Ma
Download Pdf Manuals
Related Search
Related Contents
EPC-QB - Avalue vachtung! - Fujitsu manual server Valores de referencia para Hemoglobina Glicosilada en niños Nikon COOLPIX Digital Camera Lineup User's Manual Toshiba 34HFX84 34" TV CIE-H10 User`s Manual ダイオキシン類調査における品質管理マニュアル(案) 平成 Exabyte 17D 7000DWDtK (329957) DLT Tape Drive Copyright © All rights reserved.