1. DYNAMIX VC MP SP Master Slave Ethernet Extender with Remote Power USER S MANUAL Dynamix VC MP SP USER S MANUAL Ver A 2 Overview Master Ethernet extender with remote power system delivers power and IP connectivity at distances up to 1km 3 280ft using existing or new copper twisted pair phone cable These innovative transmission techniques result in power feeding and data over a single pair phone wire and are ideal for deploying extended Ethernet where there are no or limited electricity at one end With automatic fault protection and power monitoring these ensures reliable delivery of essential power and data video to and from remote locations Operators in diverse enterprises will now be able to deploy PoE devices in any service location Install network security cameras wireless access points security RFID scanners or access control systems in any place where you have basic wire connectivity The Dynamix VC MP SP with remote power provide extended length power and Ethernet connections over one pair Cat 3 or above twisted pair phone cable The Master Slave Ethernet extender with remote power work as Ethernet to from VDSL subscriber site conversion bridge The Master Slave Ethernet extender with remote power use VDSL technology which support 5M 15 25Mbps per port symmetrical bandwidth over phone wiring with long driver capable of a maximum 1km 0 8km 0 5km 3280ft 2624ft 1680ft The front panel provides LED indic
2. Device Power ClasSifiCations ccccccsececeeeeceeeceeeeseeeeseeeeseeeeseueesaeeesaaees 21 PODeNGING Product SC Ci Ca WOM ee EE E E E E E E EE E E E E E EE 22 Appendix C Produc Speciical Ossona cn coceetes aeductandeceaeancedesecadedeescucedeueete 22 Key Features amp STING eeren EE AEAEE dine EEEE AAE AE TR EAE TETA AE EEEE ERAEN 22 Dynamix VC MP SP USER S MANUAL Ver A 2 PROGUCT Special vcsiies neos den ceandes ctances ceseden disedea cenedeaed sant dadt dats dat dott dars date doth Aas cath dal dart da sada darn Aah da sede dart ae de 23 Appendix D MOUDIESIIOOUN reccann aaa a a a aie asia 26 Diagnosing the Modenrs INdicators sirsiran E EEEE NEE EE NE EEEE EE ERT ETE 26 OY SUS Fa IANO S CS aeaa E E E 28 Appendix E Compliance and Safety Information cccccccccsecceceeeeceeececeeeceseeeeceueeeseeeeeseueeeseeesseeeessaueessaueessaseesseeeesaeeeeeas 30 AI ULI UY Sco ctceseteneatcaaih noe sasseneliecer anal Sessa cau nau meena uauaseganena eaninaatiualiaaimen acetate aueaanaaunndaaalingissnsiumtasatipsoatiuntiastinnlinaninatansdintiihs 32 Dynamix VC MP SP USER S MANUAL Ver A 2 1 Unpacking Information Check List Carefully unpack the package and check its contents against the checklist Package Contents e 1x Dynamix VC MP Master 1 x Dynamix MP VC SP Slave with Remote Power Modem Kit e 2x 48V 0 4A Power Adapter e 2xAC To DC Power Cord e 2x RJ 45 Ethernet cable e User s Manual CD Please inform you
3. the modem Ethernet port must be made using Category 5 UTP for 100Mbps Category 3 4 UTP for 10Mbps No more than 100 meters of cabling may be use between the MUX or HUB and an end node e Line Port RJ 45 Terminal block All Home network connections to the line port must use 22 26 gauge phone wiring RJ 45 and terminal block is shared and cannot be used together at the same time e We do not recommend using 28 gauge or above phone line Connecting the Master Slave Ethernet extender with remote power The master Ethernet extender with remote power two power adapters must be connected first before switch can be powered on Make sure to use AC power cord provided with your device as other AC power cord with grounding pin will make the distance reach shorter The master slave Ethernet extender with remote power has one Ethernet port which support connection to Ethernet operation The devices attached to these ports must support auto negotiation or 10Base T OR 100Base TX unless they will always operate at half duplex Slave Ethernet extender with remote power fast Ethernet port is used to connect to external power splitter POE or build in power splitter of networking devices such as IP CAM VOIP wireless AP sensor scanner or other power splitter PD side more than 15 4W The line port has 2 connectors RJ 45 and terminal block It is used to connect from master Ethernet extender with remote power using single pair phone cable to slave Ethernet extend
4. 26 Gauge diameter 27 Dynamix VC MP SP USER S MANUAL Ver A 2 System Diagnostics Power and Cooling Problems lf the POWER indicator does not turn on when the power cord is plugged in you may have a problem with the power Outlet power cord or internal power supply as explained in the previous section However if the unit power is off after running for a while check for loose power connections power losses or surges at the power outlet and verify that the fan on back of the unit is unobstructed and running prior to shutdown If you still cannot isolate the problem then the internal power supply may be defective In this case please contact your local dealer Installation Verify that all system components have been properly installed If one or more components appear to be malfunctioning e g the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning properly Transmission Mode The default method of selecting the transmission mode for Ethernet port is for 10 100Mbps Ethernet while line port is for 5 15 25Mbps speed mode Therefore if the link signal is disrupted e g by unplugging the network cable and plugging it back in again or by resetting the power the port will try to reestablish communications with the attached device via auto negotiation If auto negotiation fails then communications are set to half duplex by default Based on this type of i
5. T 5 onec IS Ea E E E EE E E E E E E E EA E EA A EEEE RE EAEE 5 22 MVS ea VS WOO CM acess PE A EE cece ded AIE A E E A T E SE A A E EE EEE AAE EE E A E A 6 FRCPC AS UNS AULA e E E A E A T 6 Pre installation Requirements ccccccceececeeeseeeceeeene ees eeeeeeee eee eeseeeee essa eeseeeeee ees eeseueesaeeseeesaueseueesueesaeeseeeseueeaeeeseeeseeeeaeeens 6 cennera TS Sessa vcs secees serene secs cen E E E E EEE E asec EE E EE A EE EE E EE E EA E 7 Connecting the Master Slave Ethernet extender with remote POWE cccccecccceececaececeeeeesaeeeeseeeeeseueeeseeeeseeeessneeesaeees 7 Connecting the Line 7 Ethernet FONG esse nei EE E EEE E EEE E EE E E E EE EE E EE 9 9 Hardware WC SCM UO sdiecedenctaeetaneeanetaueteanteuptanateusiaeeteueiecsderlncetaesiaustunetnueteuphauateutieuateunecenteveinsataeelaestaustaactaustsunteuatevadeustcuen 11 Master Ethernet extender with remote power detailed VICW cccccccsecccssccceececeuceceucecsucecsucessueessueecsueessueessueessueessueesseeesas 11 Slave Ethernet extender with remote power detailed VIQW cccccccceeccceeceeeeeeseeceseeeseeceseueeseueeseueesaeeesueeseeeeseeeeseeeeseeeesaes 12 POT NS recast parte ace ate teeta ei a eee eyecare esas cerrado ice tet aie EE EA TAA rode puaigne A ETE 13 Front 010 r 1 6 ce ee 14 PRC FeV E E EE E E E E E A E E E E EE E E T 15 A RTN are DeSCIpUO e E E E 17 Appendix A Cable Regue MEN essere E E E 19 Appendix B IEEE 802 3af PSE and Powered
6. ators of power system and interface status Full or half duplex mode of LAN operation is automatically sensed and configured VDSL link rates are configured by Master Ethernet extender with remote power over the auto speed fix speed function Therefore Master Slave Ethernet extender with remote power support auto speed fix speed plug amp play operations on the subscriber site and power protections as OVP Over Voltage Protection OCP Over Current Protection OTP Over Temperature Protection robust short circuit protection and surge protection as well as are part of an ideal solution for delivering cost effective high performance broadband multimedia services to point to point application Dynamix VC MP SP USER S MANUAL Ver A 2 Safety Warnings For your own safety make sure to read and follow all warning notices and instructions before using the device DO NOT open the unit or device Opening or removing the covers can expose you to dangerous high voltage points or other risks ONLY qualified service personnel can service the device Please contact your vendor for further information Use ONLY the dedicated power supply for your device Connect the power cord or power adapter to the right supply voltage e g 110V AC in North America or 230V AC in Europe DO NOT use the device if the power supply is damaged as it might cause electrocution If the power supply is damaged remove it from the power outlet DO NOT attempt to repair the
7. e only 1 x RJ 45 for single pair VDSL line port 1 x Terminal block for VDSL line port 1 x DIP switch for line speed setting Master only 2 x Power jack for 48V power adapter Master only 23 Power Protection System Management Cable Connection LED Indication VDSL Frequency Spectrum Dynamix VC MP SP USER S MANUAL Ver A 2 OTP Over Temperature Protection OVP Over Voltage Protection OCP Over Current Protection Robust short circuit protection VDSL and Ethernet surge protection Provides DIP Switch for changing speed mode Master only Ethernet Category 3 4 5 UTP STP Line Category 3 4 5 twisted pair phone cable Power Remote Power for system Link Active Status for Ethernet port Remote Power Link good for POV Power link good for POE Line Speed for line port Master side Transmitter 900 kHz 3 9MHz Receiver 4MHz amp 7 9MHz Slave side Transmitter 4MHz 7 9MHz Receiver 900 kHz 3 9MHz 24 Dynamix VC MP SP USER S MANUAL Ver A 2 Power Injector Slave only Using CAT 5 UL standard twisted pair phone cable Max 15 4W within 500m 1640ft Max 12W within 600m 1 968ft Max 8W within 800m 2624ft Max 5 5W within 1000m 3280ft Note Real output power depends on slave side power splitter power transmission efficiency Power Injector mode Mid span mode support connecting to Class 0 1 2 3 of PD side power splitter Distance Reach 25Mbps within 500m 164 0ft 15Mbps within 800m 2624
8. er with remote power side point to point solution Take note that master slave Ethernet extender with remote power line port cannot be used at the same time Either RJ 45 port is connected or terminal block is connected using straight connection Figure1 or cross over connection Figure2 Dynamix VC MP SP USER S MANUAL Ver A 2 Figure1 Master Slave Ethernet extender with remote power straight connection ETHERNET Ethernet Extender with Remote Power PWR Eth PoV 5M 15M 25M Master L SPE ED 1 Valid 2 Valid 1 2 Invalid Ethernet Extender ETHERNET with Remote Power PoE Eth a J PoV 5M 15M 25M L SPEED ETHERNET Ethernet Extender with Remote Power PWR Eth PoV 5M 15M 25M Master amp e e8 L SPE ED 3 Valid lt Valid 3 Invalid Ethernet Extender ETHERNET with Remote Power PoE Eth PoV 5M 15M 25M J l L SPEED Dynamix VC MP SP USER S MANUAL Ver A 2 Connecting the Line Ethernet Ports 1 The modem s line port supports max distance of 1km at 5M 5M or max speed of 25M symmetrically with distance up to 500m for data service across existing phone wiring It is easy to use which do not require installation of additional wiring Every modular phone jack in the home can become a port on the LAN Networking devices can be installed on a single telephone wire that can span within 1k
9. erleave delay is set to Oms as shown in figure 8 Figure 8 DIP switch setting Dynamix VC MP SP USER S MANUAL Ver A 2 To set the data speed to 25Mbps pin2 must be switch ON while pin1 is OFF For 15Mbps pint must be switch ON while pin2 is OFF And for 5Mbps both pins1 and 2 must be switch ON To set the interleave delay to Oms switch OFF both pins 3 and 4 For 100ms pin 4 must be switch ON while pin3 is OFF For 150ms pin3 must be switch ON while pin4 is OFF And for 300ms both pins3 and 4 must be switch ON Table shows the summary of DIP switch configuration Table 3 DIP Switch Configuration Speed Mode Dynamix VC MP SP USER S MANUAL Ver A 2 4 Firmware Description Auto and manual data speed selector description Dynamix VC MP SP_ with Remote Power solution supports real plug amp play and can do auto and manual selection of the data speed the setting of the data speed depends on the phone cable limit length they can support 5M 15M 25Mbps symmetrical data service If Master Ethernet Extender with Remote Power try to link at the data speed of 15Mbps but fails to do so then Master Ethernet Extender with Remote Power data speed must be lower due to the limitation of the phone cable length If the cable length is unsure then auto selection of the data speed at the default setting is recommended Power must be unplug before changing the data speed then power on and wait for VDSL to link again at the correct data speed
10. ft 5Mbps within 1000m 3280ft Operating Temperature 20 508 4F 122F Storage Temperature 20 708 4F 158F Humidity 10 to 90 non condensing Dimensions Master side 146mm x 97mm x 338mm 5 75 x 3 82 x 1 30 Slave side 169mm x 106mm x 33mm 6 65 x 4 17 x 1 30 25 Dynamix VC MP SP USER S MANUAL Ver A 2 Appendix D Troubleshooting Diagnosing the Modem s Indicators The modem can be easily monitored through its comprehensive panel indicators These indicators assist the network manager in identifying problems that hub may encounter This section describes common problems you may encounter and possible solutions 1 Symptom Cause Solution Note 2 Symptom Cause Solution POWER indicator does not light up green after power on Defective External power supply Check the power plug by plugging in another that is functioning properly Check the power cord with another device If these measures fail to resolve the problem have the unit power supply replaced by a qualified distributor Don t use other AC to DC power adapter Link indicator does not light up green after making a connection Network interface ex a network adapter card on the attached device network cable or switch port is defective 2 1 Power off and re power on the modem 2 2 Verify that the switch and attached device are power on 2 3 Be sure the cable is plugged into both the switch and correspond
11. function Speed mode limitation 5M 5M mode within 1km 3280ft 15M 15M mode within 800m 2624ft 25M 25M mode within 500m 1640ft Dynamix VC MP SP USER S MANUAL Ver A 2 Note We recommend phone cable that must meet Cat 5 standard or above and without clustering otherwise the above guarantee will be void Dynamix VC MP SP USER S MANUAL Ver A 2 Appendix A Cable Requirements A CAT 3 4 or 5 twisted pair cable is typically used to connect the Ethernet device to the modem A 10Base T cable often consists of four pairs of wires two of which are used for data transmission and the other two pairs are used for power transmission The connector at the end of the 10Base T cable is referred to as RJ 45 connector and it consists of eight pins The Ethernet standard uses pins 1 2 3 and 6 for data transmission purposes power supply uses pins 4 5 and ground uses pins 7 8 Table 4 Table 4 RJ 45 Ethernet Connector Pin out Assignments PIN MNEMONIC FUNCTION TX Ethernet differential Transmit signal TX Ethernet differential Transmit signal RX Ethernet differential receive signal 48V 48Vdc Power Supply Slave only 48V 48Vdc Power Supply Slave only RX Ethernet differential receive signal 8 Ground Ground Dynamix VC MP SP USER S MANUAL Ver A 2 Standard telephone wire of any gauge or type flat twisted or quad is used to connect the modem to the telephone network A telephone cable typicall
12. h IEEE802 3 10BASE T IEEE802 3u 100BASE TX and IEEE802 3af Ethernet PD class 0 1 2 or 3 standards Compliant with ETSI ITU and ANSI standards Support 5M symmetrical at distance up to 1km 3280ft 15M symmetrical at distance up to 800m 2624 ft and 25M symmetrical at distance up to 500m 164 0ft Supports 1 x RJ 45 Terminal block for VDSL line port using single pair phone cable Supports 1 x RJ 45 for fast Ethernet port with power injector Slave only Supports 1 x Dip switch for line speed setting Master only Supports Auto 5 15 25Mbps speed mode and full duplex for VDSL port Supports long packet size up to 1536 bytes Supports PBO Power Back Off function for Slave Ethernet extender with remote power Data and Remote Power work on the same telephone line Spectral compatibility with xDSL ISDN 2B1Q 4B3T Supports flow control IEEE802 3x for Full Duplex amp Back Pressure for Half Duplex Support VDSL and Ethernet surge protection Provide LED indicators for Power Link Active Status for Ethernet port and Link Speed for VDSL port Mini size and metal case for outdoor application 22 Product Specification Standard Compliant EMC Compliant Safety Compliant Environmental Protection Compliant Interface IEEE802 3 standard IEEE802 3u standard IEEE 802 3af PoE standard ITU G993 1 CE FCC VCCI EN60950 RoHS Dynamix VC MP SP USER S MANUAL Ver A 2 1 x RJ 45 for fast Ethernet port with power injector Slav
13. ing device 2 4 Verify that the proper cable type is used and its length does not exceed specified limits 2 5 Check the modem on the attached device and cable connections for possible defects 26 Dynamix VC MP SP USER S MANUAL Ver A 2 2 6 Make sure that the phone wire must be connected between the master and the slave first when both are to be powered on 2 Replace the defective modem or cable if necessary 3 Symptom Speed link cannot be established Cause Modem speed mode setting failure or phone cable length is over the specification limit of the speed mode Solution 3 1 Please make sure that the phone wire must be connected between the master and the slave when both are powered on Master will link depending on speed mode setting and phone wire length Therefore if master can t detect slave over the phone wire while both power on then this will cause the link to fail 3 2 Please check phone cable must be 24 gauge with twisted pair and without rust and the length is not over 1km 3 3 Please check the correct DIP switch setting Note Phone cable must meet CAT 5 standard or above and without clustering otherwise will cause more crosstalk issue to reduce DSL power driver 4 Symptom Modems speed mode LED are always flashing Cause Modems speed mode link are at the limit of phone cable length Solution Please change the speed mode through DIP switch Note Don t use phone cable that is untwisted pair and under 0 4mm
14. m or 500m depends on speed between the two farthest points Figure 3 Figure 3 Ethernet Extender Point to Point application i i Ethernet Extender with Remote Power Application MASTOT a opnun E One palr CAT5 phone wire J up to 1000m G280ft e CAT5 UTP Cable n j mji Power e y Splitte PC Power Egs 1 Splitter i 5 i n gt PC IP Camera Wireless AP VOD SL with Remote Power Ethernet Cable Ethernet Cable with POE Power Cable 2 Use only twisted pair cables with RJ 45 connectors that conform to Ethernet standard When inserting RJ 45 plug be sure the tab on the plug clicks into position to ensure that it is properly seated Dynamix VC MP SP USER S MANUAL Ver A 2 Notes 1 Be sure each twisted pair Ethernet cable does not exceed 100 meters 328 feet 2 Line port must use 24 26 gauge phone wiring we do not recommend 28 gauge or above 3 We advise using Category 3 4 5 cables for cable modem or router connections to avoid any confusion or inconvenience in the future when you attached to high bandwidth devices 4 Be sure phone cable has been installed before the Master Slave Ethernet extender powered on Dynamix VC MP SP USER S MANUAL Ver A 2 3 Hardware Description This section describes the important parts of the modem It features the front panel and rear connectors Master Ethernet extender with remote power detailed view Figure 4 Master Etherne
15. ndustry standard connection policy if you are using a full duplex device that does not support auto negotiation communications can be easily lost e g reset to the wrong mode whenever the attached device is reset or experiences a power fluctuation The best way to resolve this problem is to upgrade these devices to a version that support Ethernet and VDSL 28 Dynamix VC MP SP USER S MANUAL Ver A 2 Physical Configuration lf problems occur after altering the network configuration restore the original connections and try to track the problem down by implementing the new changes one step at a time Ensure that cable distances and other physical aspects of the installation do not exceed recommendations System Integrity As a last resort verify the switch integrity with a power on reset Turn the power to the switch off and then on several times If the problem still persists and you have completed all the preceding diagnoses then contact your dealer 29 Dynamix VC MP SP USER S MANUAL Ver A 2 Appendix E Compliance and Safety Information FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a computing device pursuant to Part 15 of FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not i
16. necting to an Ethernet equipped device Dynamix VC MP SP USER S MANUAL Ver A 2 Front Indicators The modem has Six LED indicators The following table shows the description Table 2 Table 2 LED Indicators Description and Operation PWR Power LED The system power is normal and functioning properly Green Master side only The system power is not ready or has malfunctioned On The power injector had detected the power splitter IEEE802 3af Ee neve viele Green The device connected to the power splitter is a non standard POE inki V LED Slave side only 9 a P P Off The power injector has not detected the power splitter ena The device has a good Ethernet connection Link Eth Ethernet LED Green eine The device is transmitting receiving data Activity Off The LAN is not connected For master eee the pauls power feeding is heey am device is not ready or has malfunctioned Green On The device is in good linkage at 5Mbps data rate Been ae device is in good linkage at 15Mbps data rate Green on The device is in good linkage at t 25Mbps data rate Off The device connection is down Dynamix VC MP SP USER S MANUAL Ver A 2 Rear Panel The following figure shows the rear connectors Figure 7 Figure 7 Rear connectors of Ethernet extender for Master and Slave respectively At quick glance you can see the DIP switch setting at default mode where it is in auto speed and int
17. nstalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver The equipment and the receiver should be connected to outlets on separate circuits Consult the dealer or an experienced radio television technician for help oS a Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment lf this telephone equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary 30 Dynamix VC MP SP USER S MANUAL Ver A 2 The telephone company may make changes in its facilities equipment operations or procedures that could affect the proper functioning of your equipment If they do you
18. power supply Contact your local vendor to order a new power supply Place connecting cables carefully so that no one will step on them or stumble over them DO NOT allow anything to rest on the power cord and DO NOT locate the product where anyone can work on the power cord DO NOT install nor use your device during a thunderstorm There may be a remote risk of electric shock from lightning DO NOT expose your device to dampness dust or corrosive liquids DO NOT use this product near water e g in a wet basement or near a Swimming pool Connect ONLY suitable accessories to the device Make sure to connect the cables to the correct ports DO NOT obstruct the device ventilation slots as insufficient airflow may harm your device DO NOT store things in the device DO NOT use the device outside and make sure all the connections are indoors There may be a remote risk of electric shock from lightning Be careful when unplugging the power due to transformer may be very hot Keep the device and all its parts and accessories out of children s reach Clean the device using a soft and dry cloth rather than liquid or atomizers Power off the equipment before cleaning it This product is recyclable Dispose of it properly Dynamix VC MP SP USER S MANUAL Ver A 2 Table of Contents SY VV MN Ses a a geese asec see tetsu oem eee tee etcetera sense eases sear E vaeo ees ene EE E 2 FUNDAN TATOO ecadeecetice ster EEE EE EE E E EREE EEE EEEE EEEE EES
19. r dealer immediately for any missing or damaged parts lf possible retain the carton including the original packing materials Use them to repack the unit in case there is a need to return for repair Dynamix VC MP SP USER S MANUAL Ver A 2 2 Installing the Modem Hardware Installation This chapter describes how to install the modem and establishes network connections You may install the modem on any level surface e g a table or shelf However please take note of the following minimum site requirements before you begin Stick the 4 rubber feet at the bottom to avoid scratches Pre installation Requirements Before you start the actual hardware installation make sure you can provide the right operating environment including power requirements sufficient physical soace and proximity to other network devices that are to be connected Verify the following installation requirements e Power requirements 2 x 48VDC 0 4A e The modem should be located in a cool dry place with at least 10cm 4in of space at the front and back for ventilation e Place the modem out of direct sunlight and away from heat source or area with a high amount of electromagnetic interference e Check if the network cables and connectors needed for installation are available Dynamix VC MP SP USER S MANUAL Ver A 2 General Rules Before making any connections to the modem please note the following rules e Ethernet Port RJ 45 All network connections to
20. t apply to any products which have been subjected to any misuse neglect or accidental damage or which contain defects which are in any way attributable to improper installation or to alteration or repairs made or performed by any person not under control of the original owner The above warranty is in lieu of any other warranty whether express implied or statutory including but not limited to any warranty of merchantability fitness for a particular purpose or any warranty arising out of any proposal specification or sample We shall not be liable for incidental or consequential damages We neither assume nor authorize any person to assume for it any other liability WARNING WARNING Warranty Void Removed DO NOT TEAR OFF OR REMOVE THE WARRANTY STICKER AS SHOWN OR THE WARRANTY IS VOID 32
21. t extender with remote power detailed view oor o0 Ethamat ertendaer wit Remot Power mF Ma ctr LINE SPEED AUTO 25M 15M 5M 41234 LED Indicators Ethernet Port Line Port Terminal Block Power On Off Switch Power Jack 2 DC 48V Line Speed Frame Ground ON OFF Fow aM LAM 25a i 6 Lipase 11 Dynamix VC MP SP USER S MANUAL Ver A 2 Slave Ethernet extender with remote power detailed view Figure 5 Slave Ethernet extender with remote power detailed view Ethe met Erten der with Remo te Po wer Slave 1 LED Indicators 2 Ethernet Port 3 Line Port 4 Frame Ground Dynamix VC MP SP USER S MANUAL Ver A 2 Front Panel The figure shows the front panel Figure 6 Figure 6 Front Panel of Ethernet extender for Master and Slave respectively ETHERNET LINE Ethernet Extender with Remote Power PWR Eth PoV 5M 15M 25M Master e 00o L SPEED Ethernet Extender ETHERNET with Remote Power Slave PoE Eth PoV 5M 15M 25M Ss L SPEED At a quick glance of the front panel it is easy to tell if the modem has power if it has signal from its Ethernet RJ 45 port if itis either providing or receiving power and if there is line signal on line port Table 1 Description of the modem front connectors Line RU 45 Terminal Block For connecting to the Ethernet extender device Ethernet RJ 45 For con
22. will be notified in advance in order for you to make necessary modifications to maintain uninterrupted service This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a CE class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 31 Dynamix VC MP SP USER S MANUAL Ver A 2 Warranty The original owner that the product delivered in this package will be free from defects in material and workmanship for one year parts after purchase There will be a minimal charge to replace consumable components such as fuses power transformers and mechanical cooling devices The warranty will no
23. y consists of three pairs of wires one of which is used for transmission The connector at the end of the telephone cable is called RJ 45 connector and it consists of eight pins VDSL signal use pins 4 and 5 for data and power transmission A telephone cable is shown below Figure 9 Figure 9 Telephone cable GE The A and B connectors on the rear of the modem are RJ 45 connectors These connectors are wired identically The RJ 45 connectors have eight positions two of which are wired The modem uses the center two pins The pin out assignment for these connectors is presented below Table 5 Table 5 RJ 11 Pin out Assignments C e mooo Unused aooo fies voses SSS s fie vostsona SS e e i i iwa s e i umso 20 Dynamix VC MP SP USER S MANUAL Ver A 2 Appendix B IEEE 802 3af PSE and Powered Device Power Classifications Table 6 IEEE 802 3af PSE and Powered Device Power Classifications 0 Default 15 4W 0 44 to 12 95W Optional 0 44 to 3 84W Optional 3 84 to 6 49W Optional 15 4W 6 49 to 12 95W 4 Reserved for Treat as Class 0 Reserved for Future Use A class 4 signature cannot be Future Use provided by a compliant powered device 21 Dynamix VC MP SP USER S MANUAL Ver A 2 Appendix C Product Specification Key Features amp Benefits Supports Plug amp Play UPnP Compliant wit
Download Pdf Manuals
Related Search
Related Contents
ISDS software User's manual (for sebum/moisture/pigment analysis) Sony SDM-HS74P/S 17" LCD Monitor Samsung SP-A400B Lietotāja rokasgrāmata Black & Decker SteamXpress AS225 User's Manual 初期設定クイックガイド(PDF・1.00MB) J4097C - ftp User Manual - EnGenius Technologies, Inc. Bedienungsanleitung Käyttöohje Operating Instructions Instrukcja 取扱説明書 - カワムラサイクル Copyright © All rights reserved.