1. mm Pin A2 CHO PinB2 CH1 A 0090060 Pin A3 CJ PinB3 CJ B Bs Front Pin A4 No connection Pin B4 No connection A1 taa Pin A5 No connection Pin B5 No connection E U Pin A6 No connection Pin B6 No connection CH2 2 41 max Type of CJC Sensor The CJC sensor is a non polarized passive negative temperature co efficient thermistor EPCOS B57869S0502F140 It is readily available in the market 025 with most third party suppliets vendors 5042 I The module supports thermocouple sensors J K N T E R S and B The Types of Thermocouple Sensors Supported following table shows the thermocouple color codes for identification Thermocouple Color Codes ANSI ANSI MC 96 1 Alloy Combination Max EMF IEC 584 3 IEC Code Color Code T C mV Color Coding Code Grade Over Max T C Extension Lead Lead Temp Temp T C Intrinsi Grade Grade Range Range Grade cally Safe J White White IRON Fe Constantan 210 6 095 Black Black J Red Red magnetic Copper 1200 C 59 563 White White Nickel 346 Cu Ni 2193 F Publication 2080 WD006A EN P September 2011 Micro800 Non isolated Thermocouple Plug in Module 7 Thermocouple Color Codes ANSI ANSI MC 96 1 Alloy Combination Max EMF IEC 584 3 IEC Code Color Code T C mV Color Coding Code Grade Over Max T C Extension Lead Lead Temp Temp T C Intrins
2. Automation representative or visit http www rockwellautomation com support Installation Assistance If you experience a problem within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running United States or Canada 1 440 646 3434 Outside United States or Use the Worldwide Locator at Canada http www rockwellautomation com support americas phone_en html or contact your local Rockwell Automation representative New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures United States Contact your distributor You must provide a Customer Support case number call the phone number above to obtain one to your distributor to complete the return process Outside United States Please contact your local Rockwell Automation representative for the return procedure Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA DU002 available at http www rockwellautomation com literature Allen Bradley Rockwell Automation MicroLogix
3. and TechConnect are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Rockwell Otomasyon Ticaret A S Kar Plaza lg Merkezi E Blok Kat 6 34752 erenk y Istanbul Tel 90 216 5698400 www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 2080 WDOO06A EN P September 2011 PN 953203 26 01 Copyright 2011 Rockwell Automation Inc All rights reserved
4. le courant ou s assurer que l environnement est class non dangereux avant de d brancher les connecteurs Fixer tous les connecteurs externes reli s cet quipement l aide de vis loquets coulissants connecteurs filet s ou autres moyens fournis avec ce produit e La substitution de tout composant peut rendre cet quipement inadapt une utilisation en environnement de Classe Division 2 e S assurer que l environnement est class non dangereux avant de changer les piles Publication 2080 WD006A EN P September 2011 4 Micro800 Non isolated Thermocouple Plug in Module Parts List Your package contains one Micro800 Non isolated Thermocouple plug in module two module fastening screws one trimmed formed bendable lead NTC thermistor and these pin out guide wiring instructions 45010 You can choose to wire the plug in before inserting it onto the controller or wire it once the module is secured in place Vane A This equipment is considered Group 1 Class A industrial equipment according to IEC CISPR 11 Without appropriate precautions there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbance Be careful when stripping wires Wire fragments that fall into the controller could cause damage Once wiring is complete make sure the controller is ree of all metal fragments Do not wire more than 2
5. torque 0 22 0 25 Nm 1 95 2 21 Ib in using a 2 5 mm 0 10 in flat blade screwdriver Wire size 0 14 1 5 mm 26 16 AWG solid copper wire or 0 14 1 0 mm 26 17 AWG stranded copper wire rated 90 C 194 F insulation max Input impedance gt 300 KQ Common mode rejection ratio 100 dB 50 60 Hz Normal mode rejection ratio 70 dB 50 60 Hz Resolution 14 bit Publication 2080 WD006A EN P September 2011 10 Micro800 Non isolated Thermocouple Plug in Module General and Environmental Specifications Attribute Value Accuracy 1 0 C for TC 25 C 77 F For more information see the Micro830 Programmable Controllers User Manual publication 2080 UM002 Channels 2 non isolated Thermocouple types supported J K N T E R S B Open circuit detection time 8 1515 ms Power consumption 3 3 V 40 mA Temperature operating EC60068 2 1 Test Ad Operating Cold EC60068 2 2 Test Bd Operating Dry Heat EC 60068 2 14 Test Nb Operating Thermal Shock 20 65 C 4 149 F Temperature surrounding air max 65 C 149 F Temperature non operating EC60068 2 1 Test Ad Operating Cold EC60068 2 2 Test Bd Operating Dry Heat EC 60068 2 14 Test Nb Operating Thermal Shock 40 85 C 40 185 F North American temp code 4 Certifications Certification when Value product is marked c UL us UL Listed Industrial C
6. Wiring Diagrams Micro800 Non isolated Thermocouple Plug in Module Catalog Number 2080 TC2 http literature rockwellautomation com FR Cette publication est disponible en fran ais sous forme lectronique fichier PDF Pour la t l charger rendez vous sur la page Internet indiqu e ci dessus IT Questa pubblicazione disponibile in Italiano in formato PDF Per scaricarla collegarsi al sito Web indicato sopra DE Diese Publikation ist als PDF auf Deutsch verfiigbar Gehen Sie auf die oben genannte Web Adresse um nach der Publikation zu suchen und sie herunterzuladen ES Esta publicaci n est disponible en espa ol como PDF Dir jase a la direcci n web indicada arriba para buscar y descarga esta publicaci n PT Esta publica o est dispon vel em portugu s como PDF Va ao endere o web que aparece acima para encontrar e fazer download da publicac o ZH E II NS HERRY j ZC FERRAR A PCP DF A gt FY EE SA TR gt KO SER set PDF USS SH WSC AA WE el MOLEC IIMA 2H SS CESS OWA Rockwell ALLEN BRADIEY ROCKWELL SOFTWARE Automation 2 Micro800 Non isolated Thermocouple Plug in Module Environment and Enclosure This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category Il applications as defined in IEC VAN 60664 1 at altitudes up to 2000 m 6562 ft withou
7. conductors on any single terminal f you insert or remove the plug in module while power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Use shielded twisted core cables to connect the sensor The shield should be grounded only at controller end Connect the thermocouples directly to the module Do not insert or remove the plug in module while power is applied otherwise permanent damage to equipment may occur Publication 2080 WD006A EN P September 2011 Micro800 Non isolated Thermocouple Plug in Module 5 Insert Module into Controller Follow the instructions to insert and secure the plug in module to the controller 44012 This plug in module is intended for use with Micro800 Family of Programmable Controllers 1 Position the plug in module with the terminal block facing the front of the controller as shown 2 Snap the module into the module bay 3 Using a screwdriver tighten the 10 12 mm 0 39 0 47 in M3 self tapping screw to torque specifications Wire the Module Follow the pinout diagram to wire your plug in module Publication 2080 WD006A EN P September 2011 6 Micro800 Non isolated Thermocouple Plug in Module 12 Pin Female Terminal Block Back View into terminal block BIM O O O Pin A1 CHO Pin B1 CH1
8. d affect normal operation Follow these guidelines when A you handle this equipment e Touch a grounded object to discharge potential static e Wear an approved grounding wriststrap e Do not touch connectors or pins on component boards Do not touch circuit components inside the equipment Use a static safe workstation if available Store the equipment in appropriate static safe packaging when not in use Publication 2080 WD006A EN P September 2011 Micro800 Non isolated Thermocouple Plug in Module 3 North American Hazardous Location Approval The following modules are North American Hazardous Location approved 2080 TC2 The following information applies Informations sur l utilisation de cet when operating this equipment in hazardous locations quipement en environnements dangereux Products marke suitable for use B C D Hazardous Locations and d CL I DIV 2 GP A B C D are in Class Division 2 Groups A nonhazardous locations only Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code When combining prod ucts within a system the most adverse temperature code lowest T number may be used to temperature code of the system of equipment in investigation by Jurisdiction at the time of instal help determine the overall Combinations your system are subject to the local Authority Having ation Le
9. i Grade Grade Range Range Grade cally Safe K Yellow Yellow Chromega Alomega 210 6 458 Green Green K Rel Re Nickel Nickel 1372 C 54 886 White White Chromium Aluminum 454 Ni Cr Ni Al 2501 F magnetic T Blue Blue Copper Constantan 270 6 258 Brown Brown T Re Re Cu Copper 400 C 20 872 White White Nickel 454 Cu Ni 752 F E Purple Purple Chromega Constantan 270 9 835 4Purple Purple E Re Re Nickel Copper 000 C 76 373 White White Chromium Nickel 454 Ni Cr Cu Ni 832 F N Orange Orange Omega P Omega N 270 4 345 Pink Pink N Re Re Nicrosil Nisil 300 C 47 513 White White Ni C Si Ni Si Mg 450 2372 F R None Black Platinum Platinum 50 0 226 40range Orange R Established Re 1396 Pt 768 C 21 101 White White odium 58 Pt 13 Rh 3214 F S None Black Platinum Platinum 50 0 236 0range 0range Established Re 1096 Pt 768 C 18 693 White White odium 58 Pt 10 Rh 3214 F B None Gray Platinum Platinum 0 0 Gray Gray B Established Re 30 6 Rhodium 1820 C 13 820 White White Rhodium Pt 6 Rh 32 Pt 30 Rh 3308 F Publication 2080 WD006A EN P September 2011 8 Micro800 Non isolated Thermocouple Plug in Module Wire the CJC Thermistor 2080 TC2 CJC Thermistor Wiring and Mounting Guide 2 41 max 1 Connect the thermoco
10. ontrol Equipment certified for US and Canada See UL File E322657 UL Listed for Class Division 2 Group A B C D Hazardous Locations certified for U S and Canada See UL File E334470 CE European Union 2004 108 EC EMC Directive compliant with EN 61326 1 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers Clause 8 Zone A amp B C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions See the Product Certification link at http www ab com for Declarations of Conformity Certificates and other certification details Publication 2080 WD006A EN P September 2011 Micro800 Non isolated Thermocouple Plug in Module 11 Notes Publication 2080 WDO006A EN P September 2011 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products At http www rockwellautomation com support you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell
11. s produits marqu s CL I DIV 2 GP A B C D ne conviennent qu une utilisation en environnements de Classe Division 2 Groupes A B C D dangereux et non dangereux Chaque produit est livr avec des marquages sur sa plaque d identification qui indiquent le code de temp rature pour les environnements dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspection par les autorit s locales qualifi es au moment de l installation AN EXPLOSION HAZARD e Donot disconnec equipment unless power has been removed or the area is known to be nonhazardous e Donot disconnec connections to this equipment unless power has been removed or the area is known to be nonhazardous Secure any external connections that mate to this equipment by using screws sliding atches threaded connectors or other means provided with this product e Substitution of any component may impair suitability for Class Division 2 e f this product contains batteries they must only be changed in an area known o be nonhazardous RISQUE D EXPLOSION A e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher l quipement e Couper
12. t derating This equipment is considered Group 1 Class A industrial equipment according to IEC CISPR 11 Without appropriate precautions there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances This equipment is supplied as open type equipment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a flame spread rating of 5V A V2 V1 VO or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition to this publication see e Industrial Automation Wiring and Grounding Guidelines Rockwell Automation publication 1770 4 1 for additional installation requirements e NEMA Standard 250 and IEC 60529 as applicable for explanations of the degrees of protection provided by different types of enclosure Preventing Electrostatic Discharge This equipment is sensitive to electrostatic discharge which can cause internal damage an
13. uples to 1 channel 0 and 1 respectively 685 ma Then connect and screw the thermistor to terminals A3 and B3 50 2 0 25 mm B3 A SSSSSS 2 Once fitted bend the black bead of the thermistor such that it makes contact with the A2 screw S S ae securely A3 The position for the thermistor as illustrated helps to compensate for thermoelectric voltages developed at screw junction equally for thermocouples connected to channels 0 and 1 If the bead is not in proper contact with the screw there will be deviation in readings due to inadequate isothermal compensation This sensor is passive non polarized and readily available in the market Wire the Module in the Field Connect the thermocouple sensors directly to the module terminals If a separate cable is used to connect the thermocouple to the module the CJC thermistor has to be mounted to the cable at thermocouple junction only Publication 2080 WDO06A EN P September 2011 Micro800 Non isolated Thermocouple Plug in Module 9 Direct sensor wiring i e Shielded sheathed thermocouple sensor IO Blue Red Red TT Process temperature measurement 45790 Direct wiring is the preferred method of wiring for thermocouples A Specifications General and Environmental Specifications Attribute Value Mounting torque 0 2 Nm 1 48 Ib in Terminal screw