SENTRI 2 User Manual - Click 24 Fire and Security Maintenance
Contents
1. Operating instructions SENTRI2 Control panel based Fire detection and alarm system BEEE a a ee 3 PS SO CANES DOCUMENIS a a nn 3 CONVENIO en ee 3 SLAO a ch a en eee 3 ADD EO a ee ee eee 3 CISCPTOSDONS IDR aa em re DO a a a RE 4 A ETS UY RE RE ET Limitation of false alarm 5 Control and indicating equipment s OTN Os 0 AIS ra E E e 5 Compact Network Node ccccccsscscssssscsecsessesssecsessessssssecsesessescatenenees 6 Repeal DANCIS sprr a Ei 6 ZONAL MIMO PANE IS re man cou 6 Description of controls and indications 7 NOMI el COP GU OPN sc E nr 11 MOW t Operale a U DUO a es 11 Weekly tests 12 How to manually raise an alarm of FIRE 13 Automatic detection of FIRE armani 14 FIU CONIO S a E EE ce 16 Typical fault ACS SAG CS no 17 DEADE NENE COMI ONS anane RT 18 Typical Disablement Messages 19 MONU CONTOS aren E EES 20 To carry out a display ARS asc 21 How to change your PIN COR 21 How to view the historic events cccccccesssesessessessssssesssrsssesseeseeseees 22 Cards inside the Control panel 22 How to save changes to memory 23 How to view active events iiss sscstsuncemnannnchannesanghssadusysudacserunctvieanatacsseen 23 2 How to set the system clock 24 How to use the external printer 25 To Switch On Off the PANIER aa eus 25 To action a Paper Feed a a ae a 25 TO conducta PINOT at mu ut 25 How to enable disable Sensing ccccccscsscsscsssssssssssssss
2. An interface unit can have up to four input output 10 lines Each line may have been given a label for display during an event To view an IO line label you will need to know the interface device address the IO line number and the loop number which can found in the site specific documentation held by the person responsible for the fire alarm system a D Press the MENU ON OFF button Press the F3 button to select Info Ignore step c if an external printer is not fitted or is switched off To display an I O line label press the F1 button to select Display or to print an I O line label press the F2 button to select Print Notice Display or Print appears on the screen Press the F4 button to select lt etc gt Press the F2 button to select Label Notice Label appears on the display Press the F2 button to select IO Line Notice IO Line followed by a flashing cursor appears on the display Use the keypad to enter an input output line number from a range 1 to 4 Press the F2 button to select Device Notice Device followed by a flashing cursor on the display Use the keypad to enter a Device number 1 200 Press the F2 button to select Loop Notice Loop followed by a flashing cursor appears on the display Use the keypad to input a loop number 1 or 2 Press the F2 button to select Enter Notice the selected label information is either displayed or printed How to view
3. entry in the log book of the the event event for future reference 13 Automatic detection of FIRE Automatic detection of FIRE With the panel door open A fire in your protected premises is automatically sensed at any To cancel You can stop the panel buzzer trom one of the fire detection devices installed in the building such as ouzan SURENG a sensor or a fire input from an interface The control panel Cancel Buzzer actions the alarm sounders in the system and at the same time gives the details of the fire event The event indication is repeated Press at all repeat indicator panels in the system Display reads Buzzer cancelled To silence When the emergency is over the alarm f alarms sounders can be silenced Panel 6 m _ aenea Silence Alarms FIRE ALARM PUZZer an l Press Display reads Alarms silenced To reset To return the system to normal condition system clear any residual smoke or heat from Fault r Fire sensors and replace the glass in any IstFIRE MCP Zone 1 Qiu aa verry manual call points where the glass was broken System Fault First Fire occurred at Sounder z r OUND time 08 43 10 Sun 17 March 2013 Ensure the fire system is checked by delay cB253 your servicing organisation if there test cB254 has been fire damage in the protected l area Disablement Power Reset Previous Press Display reads System being Reset please wait
4. fire detection and alarm a turn and remove it from the call point ee tan eed be tested It is important to inform the alarm receiving centre Ei be paneidooroper The weekly fire test can be carried out at a manual call point without To cancel You can stop the panel buzzer from breaking the call point glass buzzer sounding Cancel Buzzer O Insert the test key into the keyhole located on the bottom centre front face of the call point and turn the key one quarter of a turn clockwise Press Display reads Buzzer cancelled Manual Call point r To silence When the test is complete the alarm gt alarms sounders can be silenced Test Key a O 0 INS Silence Alarms Panel buzzer p 0 On Q Flashing oe Display reads Alarms silenced ayy To reset To return the system to normal O system condition clear any residual smoke or heat from sensors and replace the Fault Te Fire glass in any manual call points where 1istFIRE MCP Zone 1 Power Fault oT verify the glass was broken Reset YT BOS CUATIMR First Fire occurred at Sounder Time 13 43 10 Sun 17 March 2013 Delay EEE Press Q Test CB254 Display reads System being Reset Disablement Power please wait Previous Record Make an entry in the log book of the the event event for future reference At this point the test key is retained in the call point O Check the alarms are sounding in the build
5. hooks on the top of the front cover are locked onto the call point assembly Turn the test key anticlockwise one quarter of a turn such that the glass is held under the yellow arm The call point is now ready for normal operation SEN 891 Spare MCP glass Pack of 10 Resetting the resetable element on a Manual Call Point Slide the keyhole cover upwards to expose the keyhole Insert the test key in the keyhole and turn it clockwise by one quarter of a turn Then turn the test key anticlockwise by one quarter of a turn to reset the call point element ou YELLOW ARM Test Key 33 Maintenance Battery replacement It is recommended where batteries are installed they must be replaced at 4 Yearly intervals from the date the system is first commissioned Any servicing work on the system must be carried out by a suitably trained person such as an engineer from the servicing organisation Repair function Any wiring fault on the system must be rectified by an engineer from the servicing organisation for contact details see the log book A wiring fault will require correction to the wiring before running a Repair command at the main panel The repair function is accessible using customer level 2 password however under normal circumstances it is unnecessary to use this function a Press the MENU ON OFF key b Press the F1 button to select Test Eng c Press the F4 button to select UserCode Noti
6. location in a network A previously entered label can be modified a D C Press the MENU ON OFF button Press the F2 button to select Set Up Press the F4 button to select UserCode Notice a message on the display Enter access code followed person responsible for the fire alarm system or it can have contact phone number of the servicing organisation Example For service call phone number A previously entered label can be modified by a flashing cursor Use the keypad to input the PIN a Press the MENU ON OFF button BOGAN DEEE ENEA UNGT b Press the F2 button to select Set Up DATES 6 Te CANON ONCERORECCESEUCSS c Press the F4 button to select UserCode Notice a message on e Press the F1 button to select Modify Notice Modify the display Enter access code followed by a flashing cursor appears on the display Use the keypad to input the PIN and then press Enter button f Press the F1 button to select Label Notice Label d Press the F4 button once to select lt etc gt appe aie OMS Er e Press the F1 button to select Modify Notice Modify appears g Press the F4 button once to select lt etc gt on the display h Press the F2 button to select Local Notice local f Press the F1 button to select Label Notice Label appears on appears on the display Press the F2 button to select Enter Notice the previous label appears on the display with a flashing first chara
7. lt etc gt Press the F4 button to select UserCode Notice a message on the display Enter access code followed by a flashing cursor Use the keypad to input your PIN and then press Enter button Press the F3 button to select Loop Map or Map On selecting Map you have a choice of either Loop Map or Net Map On selecting Loop Map notice Loop Map followed by a flashing cursor appear on the display On selecting Net Map notice Node followed by a flashing cursor appear on the display Use the keypad to enter the loop number or node number and then press F3 to select Enter Notice the map is either printed or displayed 29 Editing labels Editing labels followed by a flashing cursor appears on the display Any changes to labels must be backed up h Use the keypad to input a Device number to the Memory see the on How to i Press the F2 button to select Loop Notice Loop followed by save changes to the memory a flashing cursor on the display Use the keypad to input a loop number either 1 or 2 How to edit a device label j Press the F2 button to select Enter Notice the previous label There can be up to 200 devices connected to a loop appears on the display with a flashing first character to prompt devices like fire sensors and manual call points Each the modification if there is no label the line is blank device can be given a label to identify its location in the s
8. Record Make an entry in the log book of the the event event for future reference SenTRI2 fire system Multiple fires Previous Next B amp Use the Previous or Next buttons to scroll the fire events The 1st Fire will always appear at top of display All subsequent fires appear beneath the 1st Fire 1 The zonal indicators show zones in fire condition If the panel is configured the first zone to go into a fire Zones 1 gt condition may be indicated by a flashing zone number all other zones in fire give a steady indication Each fire is logged in the Historic Events log which can be recalled using the menus See How to view the Historic Events To verify an alarm Upon receipt of a fire condition the alarm sounders in the system can be delayed from sounding by using the Verify button If required by This allows time to investigate the cause of the alarm site procedures Note the delayed sounders will operate after the verify period has timed out Verify i Verify O Press 15 Fault conditions Fault conditions O With the panel door open A fault in the system such as failure of mains power to the panel or removal To cancel You can stop the panel buzzer from of any monitoring device will cause a Fault condition to appear at the buzzer sounding control panel The control panel will provide details of the event this event Cancel Buzzer indication is repeated at all repeat panels and m
9. able e Press the F2 button to select IO Line At the flashing cursor using the keypad input an IO line number f Press the F2 button to select Device At the flashing cursor using the keypad input a device number from a range 1 to 200 g Press the F2 button to select Loop At the flashing cursor using the keypad input a loop number from a range 1 to 2 h Press the F2 button to select Enter Notice the action has been processed and a message appears on the display IO line disabled enabled at Card n The disablement light will illuminate upon disablement of an IO line 26 How to enable disable aux relay The control panel has two auxiliary relays that provides voltage free contacts to control external equipment in the event of a fire or fault condition The operation of the relays can be disabled or enabled a Press the MENU ON OFF key b Press the F1 button to select Control c Press the F4 button to select UserCode At the flashing cursor using the keypad input your PIN code and then press the Enter button d To disable the auxiliary relay press the F2 button to select Disable or press the F1 button to select Enable This puts Disable or Enable on the display e Press the F4 button three times selecting lt etc gt on each occasion and then press the F2 button to select Aux Rly At the flashing cursor using the keypad input an auxiliary relay number or range 1 2 f Pres
10. ay also be displayed at zonal and mimic panels in the system Press Display reads Buzzer cancelled x Ep What You need to ensure the panel is Panel Qr on Q Fiashing must be returned to normal condition All NES done fault repairs must be undertaken by engineers responsible for the system Refer to the contact details in the log book Record Make an entry in the log book of the B Fault Eee ae the event event for future reference Power Fault Time 13 45 44 Sun 17 March 2013 Verify amp F Monitored input O C Multiple The number n following the word system Fautt Sounder faults Fault located top left on the display elay cB253 denotes the number of faults present in ce254 the system Each fault is logged in the Historic Disablement Owe Events log which can be recalled Previous using the menus See How to view the Historic Events Only the trained engineer who is responsible for the fire alarm system must attempt any fault rectification work For advice please call your servicing organisation see contact details in the Log book SenTRI2 fire system Typical fault messages The table below shows some of the more typical fault messages and indications that may appear at the panel if there are faults in the system It also gives the meaning and possible rectification action for each fault O On O Flashing I Message Indication Meaning Action Mains failed Fault 0 Power Fa
11. button will sound all the system alarms This button is only pressed in an emergency or at other agreed times for example when conducting a sounder test or practice evacuation Pressing the Silence Alarms button will silence the system alarms Pressing the Reset button will clear any fires and return the panel to its normal condition If a fire condition occurs immediately after reset then the indicated device should be investigated If the Verify facility has been set up then pressing the Verify button in the event of a fire condition increases the time delay before the sounders are activated This gives the user time to investigate the cause of the alarm and the option of cancelling the alarm within the delay time period These buttons can be configured during commissioning to action user defined tasks such as the disablement of devices in areas where smoke may be generated due to maintenance work or where plant shutdown is required Descriotionof controls andindications Controls D These four buttons are used to scroll the displayed text ABC DEF When entering a label each press of a key will scroll the character string for example key 2 will scroll AB C2abc key 1 will scroll 1 amp GHI JKL MNO The bottom row of text keys explained The U button is used to enter a SPACE between characters PORS TUV WXYZ The INS key allows text to be moved one position to the right The DEL key allows a character to be deleted 7 T
12. ce a flashing cursor and a message on the display Enter access code Use the keyboard to input your password and then press the Enter button d Press the F1 button to select Loop and F1 button to select Repair notice Loop followed by a flashing cursor on the display Use the keypad to input a loop number 1 or 2 and then press the F2 button to select Enter 34 SenTRI2 fire system Notes Lf SMS by Honeywell Novar Systems Limited Manufactured by Honeywell Life Safety Systems 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN United Kingdom 13 DoP Product No 030 CPR 2013 SENTRI2 030 CPR 2013 SENTRI2 PO 030 CPR 2013 SENTRI2 SP EN54 2 1997 A1 2006 EN54 4 1997 A1 2002 A2 2006 SENTRI2 EN54 2 amp 4 SENTRI2 PO EN54 2 amp 4 SENTRI2 SP EN54 2 amp 4 WEEE Directive At the end of their useful life the packaging product and batteries should be disposed of via a suitable LY At the end of their useful life the packaging Intended for use in fire detection and fire alarm systems recycling centre EO product and batteries should be disposed of in and around buildings Do not dispose of with your normal household waste via a suitable recycling centre and in i i Refer to 030 CPR 2013 for level or class of performance declared Do not bum accordance with national or local legislation for details see website www smsfire co uk Gent by Ho
13. cter to prompt you to edit the label If there is no label then the line is blank Using the keypad to enter a label of up to 40 characters in length and then press the Enter button the display g Press the F4 button once to select lt etc gt h Press the F3 button to select Custom Notice Custom appears on the display Press the F2 button to select Enter Notice the previous label appears on the display with a flashing first character to prompt you to edit a label If there is no label then the line is blank Using the keypad enter a label of up to 40 characters in length and press the Enter button 32 SenTRI2 fire system Maintenance Replacing the glass on a Manual Call Point a Disengage the front cover from the call point assembly using the end of the test key Insert the key into the slots E on the underside of the call point to compress the retaining tabs and the from the bottom edge lift out the cover Carefully remove broken glass from the call point A Take appropriate precautions when clearing the broken glass to prevent injury Insert the key in the keyhole and turn the key such that the tab is at position F and then insert a new glass as shown Ensure the glass has engaged into the yellow arm Hook the front cover onto the top edge of the call point assembly and then push the bottom edge down until a click is heard and the cover shuts onto the main assembly Check both
14. disabled and if appropriate re enable the master i Soinder O alarms A Any changes to the setting of an automatic disablement must only be attempted by a trained engineer who is responsible for the fire alarm system see contact details in the Log book 19 Menu controls Menu controls a NS Panel beeps on button press I O Flashing I Fault amp Power Fault Fire Verify System Fault Sounder amp Delay SenTRI 2 Fire System Desioned tO HNS4 oe 2 44 z a CB253 Test Disablement cB254 conmeeWi Sores mri test Eng Power Menu On Off Previous Cancel Buzzer oo oOo Do 9 The MENU ON OFF button activates the function keys F1 to F4 for the selection of menu prompts that appear above the function keys on the display At any level in a menu single press of the MENU ON OFF key aborts an operation However as an alternative the Quit option can be selected to exit the function mode If the time taken between key presses exceeds five minutes then the control panel will automatically remove the menu options from the display and give a system status indications The Params option is a Help function to provide information to the user regarding the type of input data required Most of the functions in the Control Setup and TestEng menu options are protected with password entry The password is programmed during the co
15. e event s Press the F2 button to select Print a Press the MENU ON OFF button Notice Print appears on the display b Press the F2 button to select Set Up d Press the F1 button to select Active Notice Active appears on the display To view events on the local panel c Press the F4 button to select UserCode At the flashing and on a card by card basis then press the F3 button to cursor using the keypad input your PIN code and then select Card notice on card appears on the display press the Enter button Enter the card number To view events at another node in a networked system then you will need to know the node number Press the F4 button to select Node and enter a node number from a range 1 to 255 d Press the F4 button to select lt etc gt and then press the F3 button to select Save e Press the F2 button to select Enter Notice all of the active Fire Fault and Disablement events are displayed in turn Press the F2 Previous and F3 Next button to scroll e Press the F2 button to select Enter Observe confirmation through the displayed events of data backed up The Save option is only available if Access level 2 PIN is set up f Press the F4 button to select Quit when viewing of events is complete 23 How to set the system clock How to set the system clock An incorrect setting of the system clock will affect any time related sensor configuration and con
16. e for the fire alarm system should arrange for suitable investigation and appropriate action on occasion of every false alarm For a system having less than 40 automatic fire detectors installed an in depth investigation should be instigated on occurrence of two false alarms in any rolling 12 months For a system having more than 40 automatic fire detectors an investigation should be instigated if there has been O one false alarm for every 20 installed detectors in the system in any rolling 12 months or D two or more false alarm occurrences from a single device Control and indicating equipment On occurrence of a fire fault or disablement event in the protect premises the event is quickly indicated at a control and indicating equipment The control and indicating equipments are installed in accessible location and can be operated by the person responsible for the fire system Control panel The control panel is the heart of the system It is normally located near to the main entry or exit point of the protected premises The control panel continuously monitor devices that are connected to each device loop The device loop cable is routed through the protected premises to cover all areas with both ends of the loop terminating at the control panel On the loop cable are installed devices such as fire sensors that constantly monitor the environment for fire Alarm devices on the loop provide alert and evacuation alarm to warn
17. he BKSP button will delete previous character CRC When entering a data range such as a range of devices the key THRU is used for example 1 5 2 This button is pressed to acknowledge an entry of data such as a label 10 SenTRI2 fire system Normal condition When a system is operating normally with no fault or disablement present then the panel s display shows O Panel healthy message and Network Healthy message and O only the Power green indicator is lit Fault Panel healthy Power Fault System Fault SenTRI 2 Fire System Designed to EN54 Pt 2 amp 4 Delay Test Disablement Previous O n 11 I Flashing I Fire Verify Sounder CB253 CB254 Power How to operate a U button The U1 and U2 buttons may have been configured during commissioning to action user defined tasks such as the disablement of devices in areas where smoke may be generated due to temporary maintenance work or to action a plant shutdown if required The function of these U buttons should be written on the label that is fitted on the back of the panel s outer door O With the panel door open To activate a You can activate the U button predefined task by operating the U button Press Cor n can be 1 or 2 11 Weekly tests O Turn the test key anticlockwise one quarter of Every week during normal working hours the
18. he keypad to input a Device number or range 1 200 g Press the F2 button to select Loop Notice Loop followed by a flashing cursor appears on the display Use the keypad to input a loop number 1 or 2 h Press the F2 button to select Enter Notice the selected label information is either displayed or printed 27 How To view a zone label How to view a zone label A zone is a subdivision of a building used for fire detection To view a zone label you will need to know the zone number You can find this information in the site specific documentation held by the person responsible for the fire alarm system a D 28 Press the MENU ON OFF button Press the F3 button to select Info Ignore step c if an external printer is not fitted or is switched off To display a zone label press the F1 button to select Display or to print a zone label press the F2 button to select Print Notice Display or Print appears on the screen Press the F4 button to select lt etc gt Press the F2 button to select Label Notice Label appears on the display Press the F4 button once to select lt etc gt Press the F1 key to select Zone Notice Zone followed by a flashing cursor appears on the display Use the keypad to input a Zone number from a range 1 128 Press the F2 key to select Enter Notice the selected label information is either displayed or printed How to view a I O line label
19. ice Print appears on the display O Card 14 is always the memory that resides on the Main controller board Press the F2 button to select Historic Notice Historic followed by a flashing cursor appears on the display Use the keypad to input an event number 1 to 255 If you want to view events at another node in a networked system then you will need the node number Select Node and enter the node number The event number 1 is always the most recent event Press the F2 button to select Enter Notice the required event s are displayed or printed depending on your selection SenTRI2 fire system How to save changes to memory How to view active events If you make any changes to a Labels or Password then you An active event is an event that is still present and has not must save these to the NVM Non Volatile Memory or Memory cleared You can view all active Fire Fault or Disablement of the panel events Changes made to labels and password can a Press MENU ON OFF be saved to the panel memory NVM this can b Press the F3 button to select Info Ignore step c if an external printer is not fitted or is switched off only be done when there are no disablements present on the system c To display the event s Press the F1 button to select The following procedures assume a customer password PIN Display Notice Display appears on the display is setup at the panel To print th
20. ific documentation held by the person responsible for the fire alarm system a D C Press the MENU ON OFF button Press the F2 button to select Set Up Press the F4 button to select UserCode Notice a message on the display Enter access code followed by a flashing cursor Use the keypad to input your PIN and then press Enter button Press the F4 button once to select lt etc gt Press the F1 button to select Modify Notice Modify appears on the display Press the F1 button to select Label Notice Label appears on the display g Press the F4 button once to select lt etc gt h Press the F1 button to select Zone Notice Zone followed by a flashing cursor appears on the display Using the keypad enter a number from a range 1 to128 Press the F2 button to select Enter Notice the previous label appears on the display with a flashing first character to prompt you to edit the label If there is no label then the line is blank Using the keypad to enter a label of up to 32 characters in length and then press the Enter button 31 How to edit a local panel label How to edit custom label custom message or label is displayed beneath the Designed to EN54 Pt 2 amp 4 line on the panel The message or label can be up to 40 characters in length and it can be contact information of the How to edit a local panel label A label is normally given to the control panel to identify its
21. ing and an indication is given of the fire event 12 SenTRI2 fire system How to manually raise an alarm of FIRE ee le panel ager oven If you see a fire in the protected premises and want to raise a fire To cancel You can stop the panel buzzer trom alarm to warn occupants in the building you can do this manually by buzzer sounding O Going to the nearest manual call point that is located away from the fire hazard O Press hard with a thumb onto the centre of the glass until it breaks Press Display reads Buzzer cancelled Cancel Buzzer Manual Call point To silence When the emergency is over the alarms alarm sounders can be silenced Silence Alarms LINN Panel Press FIRE ALARM PUzZzer Display reads Alarms silenced To reset To return the system to normal system condition clear any residual smoke d or heat from sensors and replace QO on Q Flashing the glass in any manual call points where the glass was broken Ensure the fire system is checked by your servicing organisation if there has been fire damage in the Fire protected area Verify amp system Fault First Fire occurred at Sounder Reset Time 11 43 10 Sun 17 March 2013 amp Delay CB253 Press Test CB254 i ts o Display reads System being Reset Disablement Power please wait Fault Nails istFIRE MCP Zone 1 Power Fault fl N Previous Record Make an
22. int MCP individually not as part of a range DISABLING A MCP IS NOT RECOMMENDED b Press the F1 button to select Control c Press the F4 button to select UserCode At the flashing cursor using and the keypad input your PIN code and then press the Enter button d To disable a device Press the F2 button to select Disable To enable a device Press the F1 button to select Enable The display shows either Enable or Disable e Press the F1 button to select Sensing Notice Device followed by a flashing cursor appears on the display Use the keypad to input a device number or range 1 200 f Press the F2 button to select Loop Notice Loop followed by a flashing cursor on the display Use the keypad to input a loop number or range 1 2 g Press the F2 button to select Enter This is confirmed by Device s enabled or Device s disabled The Disablement light is lit upon disablement of the divice 25 How to enable disable a zone How to enable disable a zone zone is a subdivision of your premises that is protected by the fire alarm system There can be up to 128 zones configured in a system Any zone operation can be disabled or enabled You will need to know the zone number this can be found in the site specific documentation held by the person responsible for the fire alarm system a Press the MENU ON OFF key b Press the F1 button to select Control c Press
23. ls Delay CB253 to scroll fire Test CB254 events Disablement Power SENTRI oa Previous Next Menu On Off Cancel Buzzer Key lock to open D F1 F2 FS 4 ww the outer door on Inner door Outer door Indications doo 3 4 Sound Alarms Silence Alarms ABC DEF GHI JKL MINT PQRS TUV WXYZ O O THRU LI BKSP Operating instructions Access level 2 and Log Book Controls Descriotionof controls andindications Indicators Display Zones 517 red vie Power _ 1 green a Fire red Verify ji IS amber Fault O 1 amber System Fault O f r gt amber vie Disablement Oz be CB253 or CB254 wie 1 amber Power Fault 1 amber E Sounder On 1 amber Del O PUS amber i Test gt A amber Description The Display provides messages of the system status events by means of 8 lines by 40 characters per line display Secret until lit fire zone indicators When the Zones text and number s are illuminated it indicates that a FIRE has been detected in the indicated zone s When illuminated it indicates that a supply to the panel is present When illuminated it indicates that a FIRE has been detected in the protected premises When illuminated it indicates that the Verify button has been pressed and the alarm sounders in the system are delayed from sounding When illuminated it indicates that a FAULT has been detected in
24. mmissioning of the system and is passed on to the site person responsible for the fire alarm system An open access to controls under User code is undesirable so it is recommended that a customer password is setup Where a password code is not set up there is an open entry to operate the controls under User Code Where this is true the instructions for entering the access code password or PIN in the following instructions should be ignored 20 To carry out a display test You can test the message display and the indicators on the control panel a Press the MENU ON OFF key and then the F4 key to select Test Eng b Press the F1 key to select Disp Test Check that the following things happen The display clears the indicators illuminate the buzzer sounds two distinct tones and then the display shows the system status message The display test lasts for about 4 seconds SenTRI2 fire system How to change your PIN code The following terms Password PIN Usercode and Access code mean the same and are used interchangeably Customer user PIN code password is normally set up by the servicing organisation during commissioning of the fire alarm system The customer PIN code is set up for the end user The person responsible for the fire alarm system should be aware of this PIN code For security the PIN should be changed on a regular basis previously created PIN can be changed a Press the MENU ON OFF b
25. neywell reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions of changes Hamilton Industrial Park Waterside Road Leicester LE5 1TN Website www smsfire co uk Telephone 44 0 116 246 2100 Technical support www smstoolbox co uk Fax UK 44 0 116 246 2016 36 4188 1038 issue 1_ 08 14 Sentri2 ops
26. occupants in the protected premises in the event of a fire Zone indicators to locate the area s ina building where fire s are detected Control and indicating equipment Repeat panels Zonal Mimic panels There may be one or more repeat panels installed in There may also be a number of mimic and zonal mimic panels the protected premises to provide secondary installed in the protected premises to provide visual indications indications of the system condition The larger repeat in a graphical and zonal format panel additionally provide system controls The Normally one is installed next to the main control panel repeat panels are usually located near to secondary There may be additional panels installed in other areas of the entry and exit points of the protected premises protected premises to cover sub division of the premises al come zone f omer ws om we cou vos rower ve ao esses nis BA j LIE ee ee BE bee CCC ial BAPE Dee BEC COCO zone Repeat indicator panel provides system indications A3 Zonal panel Repeat panel Provides zonal indication of events provides system indications and controls SenTRI2 fire system Description of controls and indications Open the front door to reveal the controls Fault Fire Message Panel healthy Display Power Fault Verify System Fault SenTRI 2 Fire System Sounder Access level 1 Designed to EN54 Pt 2 amp 4 Contro
27. s Fault hae There is a mains supply failure at an interface Check the fuse and mains supply to the failed o1 unit repeat panel or mimic panel equipment Device Battery Fault cy The battery supply at an interface unit repeat Check the battery and replace if fault 2 1 panel or mimic panel has failed the load test necessary 17 Disablement conditions Disablement conditions disablement condition is the manual or automatic disablement of a part of the fire detection system An automatic disablement may be pre configured for your premises to disable smoke sensors during the normal working hours in areas where smoke or dust may be present A manual disablement may be necessary where building work is being undertaken that could result in a false alarm O On Q Flashing Fault Fire Disable 1 Time 13 45 44 Sun 17 March 2013 Verify Device Disabled at card 1 System Fault Sounder amp Power Fault Delay cB253 Test CB254 D Disablement Power Previous This indication is only given if a sector sounder device or master alarms in the system are disabled What must be done Investigate the reason for the disablement and re instate the devices if appropriate Record the event Where necessary make an entry in the log book of the event for future reference Multiple Disablements The number n following the word Disable located top left on the display denotes
28. s the F2 button to select Enter Notice the action has been processed and a message appears on the display Aux Rly n disabled enabled The Disablement light will illuminate upon disablement of an auxiliary relay Other enable disable options There are other options such as Sounders Command Build Group and Communication that are accessible for enablement and disablement for further advice contact your servicing organisation see the Log book for contact details SenTRI2 fire system How to view a device label Each device in the sytem is given a location label at the time the system is commissioned to identify its installation position To view a device label you will need to know the device address and the loop on which it resides which can be found in the site specific documentation held by the person responsible for the fire alarm system a Press the MENU ON OFF button b Press the F3 button to select Info Ignore step c if an external printer is not fitted or is switched off c To display a device label press the F1 button to select Display or to print a device label press the F2 button to select Print Notice Display or Print appears on the screen d Press the F4 button to select lt etc gt e Press the F2 button to select Label Notice Label appears on the display f Press the F3 button to select Device Notice Device followed by a flashing cursor appears on the display Use t
29. sequently results in incorrect event time information a Press the MENU ON OFF key and then the F2 key to select Set Up b Press the F4 key to select User Code At the flashing cursor using the keypad input the PIN code and press the Enter button c Press the F1 key to select Set Clock The system clock is displayed on the screen Check the hour digits are flashing d Press the F2 or F3 key to Retard or Advance to the desired setting e Press the F1 key to select Next Check that the Minute digits are now flashing f Press the F2 or F3 key to Retard or Advance to the desired setting g Press the F1 key to select Next Check that the Date digits are now flashing h Press the F2 or F3 key to Retard or Advance to the desired setting i Press the F1 key to select Next Check that the Month digits are now flashing Press the F2 or F3 key to Retard or Advance to the desired setting Press the F1 key to select Next Check that the Year is now flashing Press the F2 or F3 key to Retard or Advance to the desired setting Press the F4 key to select Enter Check that the display now shows the new time and date Any changes made to the time and date will be automatically sent to the repeat panels in the system The system clock adjusts automatically for Day light saving if set up during commissioning Now Save the changes made to the clock settings 24 Ho
30. sssssssseesseaeees 25 How to enable disable a zone c cccccscsssecsecsesssssescsecseseseescteneensees 26 How to enable disable an 10 line 26 How to enable disable aux relay 27 Other enable disable options 27 HOW 10 VIEW a GOvVICE TDR Sans sm entente 27 How to view a zone label 28 How to view a I O line label 28 How to view the local panel label 29 To view or printa MODE are eme mer 29 FONNO ADR Sn ne ee eee 30 How to edit a device TAC lc a ee 30 How to edit an Input output line label 30 How to edit a zone label ve a ee nn enr 31 How to edit a local panel label 32 How to edit custom label 32 MOITI TONER E EE A E EE nn 30 Replacing the glass on a Manual Call Point 33 Resetting the resettable element on a Manual Call Point 33 Be iy Fe OI ACS MONS a nates 34 Repair MITCH ON mesinna inann e Er nE 34 This is the first issue of the operating instructions for the SenTRI2 fire detection and alarm system for Sentri2 panel having enhanced loop capabilities Associated Documents SenTRI2 panel based system Installation instructions Log Book Conventions This is a note to highlight important text that is normally hidden in the main text This is either a caution to prevent damage to the equipment or a warning to inform of dangerous conditions that may result in injury or death SenTRI2 fire system Symbol Keys SEIP O Wha
31. t you will see What you will hear dem On A fire condition LED illuminated On O Flashing LED illuminated Flashing Not applicable LED Light emitting diode light MCP Manual call point NVM Non Volatile Memory OC or O C Open circuit IO or I O Input or Output SC or S C Short circuit Text Denotes menu option that appears on display Text Denotes physical keys on keypad User responsibility User responsibility Your fire alarm system should have been designed installed and commissioned to your site specific requirements and in accordance with the requirements of BS5839 Part 1 You should have received instructions about your system during the handover stage and must make arrangements to ensure the system is regularly tested and maintained It is recommended that the person responsible for the fire alarm system should ensure the system is tested and maintained in accordance with the requirements of BS5839 Part 1 and become familiar with the operation of controls and be able to interpret the indications given at the control panel O keep up to date all documentation associated with the system Any servicing work on the SenTRI2 system must be carried out by a suitably trained person please refer to your servicing organisation Daily BS 5839 Part 1 states that the system should be inspected daily to ensure O That a normal indication is given at the con
32. the F4 button to select UserCode At the flashing cursor using the keypad input your PIN code and then press the Enter button d To disable a zone Press the F2 button to select Disable or press the F1 button to select Enable e Press the F4 button to select lt etc gt and then press the F2 button to select Zone At the flashing cursor using the keypad input a zone number or range 1 128 f Press the F2 button to select Enter Notice the action has been processed and a message appears on the display Zone n enabled or Zone n disabled The Disablement light will be illuminated upon disablement of any zone How to enable disable an IO line An interface input output line can be disabled or enabled You will need to know the IO line device and loop numbers these numbers can be found in the site specific documents held by the person responsible for the fire system An output line of an interface unit may be assigned to a sector and can only be disabled by disabling that sector This has the effect of also disabling all other devices in the sector a Press the MENU ON OFF key b Press the F1 button to select Control c Press the F4 button to select UserCode At the flashing cursor using the keypad input your PIN code and then press the Enter button d To disable an IO line press the F2 button to select Disable or press the F1 button to select Enable the display reads Enable or Dis
33. the fire detection and alarm system When illuminated it indicates that a fault has occurred with the system processor It is important to investigate this fault because the fire system may not be able to detect fires When illuminated it indicates that a part of the system has been disabled When illuminated it indicates command builds 253 or 254 has been activated When illuminated it indicates the battery or mains supply to the panel has failed When illuminated always with either the FAULT light or the DISABLEMENT light it indicates that there is a sounder fault flashing indication or sounder disablement steady indication When illuminated it indicates that one or more delay blocks are setup on the panel When illuminated it indicates one or more zones are in Test mode Controls Menu On Off Ja G Cancel Buzzer Q Sound Alarms Q Silence Alarms Q Reset Q Verify gG G SenTRI2 fire system Description Pressing the Menu On Off will enable disable the on screen menu facility which gives access to the system menus The Fn buttons are used to select a function and sub functions at the panel menus that appear on the display Each option in the menus corresponds to one of the function buttons and pressing a button will select the option which appears above it on the display The Cancel Buzzer button when pressed will stop the internal panel buzzer from sounding Pressing the Sound Alarms
34. the local panel label When there is a network of control panels connected together in a system then each panel is usually given an identification label also referred to as the Local panel label a Press the MENU ON OFF button b Press the F3 button to select Info Ignore step c if an external printer is not fitted or is switched off c To display a local panel label press the F1 button to select Display or to print a local panel label press the F2 button to select Print Notice Display or Print appears on the screen d Press the F4 button to select lt etc gt e Press the F2 button to select Label Notice Label appears on the display f Press the F4 button once to select lt etc gt g Press the F2 key to select Local Notice Local appears on the display h Press the F2 key to select Enter Notice the selected label information is either displayed or printed SenTRI2 fire system To view or print a map map provides information on devices that are connected to a loop off a control panel in a fire alarm network a D Press the MENU ON OFF button Press the F3 button to select Info Ignore step c if an external printer is not fitted or is switched off To display a loop map press the F1 button to select Display or to print a loop map press the F2 button to select Print Notice Display or Print appears on the screen Press the F4 button to select
35. the number of disablements present in the system Each disablement is logged in the Historic Events log which can be recalled using the menus see How to view the Historic Events 18 SenTRI2 fire system Typical Disablement Messages The following table shows some typical disablement messages and indications that may appear at the panel O On O Flashing Message Indication Meaning Action Zone Disabled Dj we The zone specified has been manually or If manually disabled then investigate and isablement at card n 1 automatically disabled if necessary re enable the zone Device disabled Dj 2 A device connected to the loop circuit has been If manually disabled then investigate and isablement at card n 1 manually or automatically disabled if appropriate re enable the device Sounder Oy Additional indication is given if it is a sounder re device Sector disabled Dicablement O The fire alarm sector on loop n has been If manually disabled then investigate and at card n ar manually or automatically disabled if appropriate re enable the sector i Sounder O Disabled Aux Disablement O The auxiliary relay n in the control panel has If manually disabled then investigate and Relay n er gt been manually or automatically disabled if appropriate re enable the aux relay Master alarm s Disablement O The master alarms have been manually or If manually disabled then investigate disabled ore automatically
36. then press Enter appears on the display button Press the F1 button to select Label Notice Label appears on the display e Press the F1 button to select Modify Notice Modify appears on the display d Press the F4 button once to select lt etc gt h g Press the F3 button to select Device Notice Device 30 Press the F1 button to select Label Notice Label appears on the display Press the F2 button to select IO Line Notice lO Line followed by a flashing cursor on the display Using the keypad enter an input output number from a range 1 to 4 Press the F3 button to select Device Notice Device followed by a flashing cursor appears on the display Use the keypad to input a Device number from the range 1 to 200 Press the F2 button to select Loop Notice Loop followed by a flashing cursor on the display Use the keypad to input a loop number 1 or 2 Press the F2 button to select Enter Notice the previous label appears on the display with a flashing first character to prompt you to edit a label If there is no label then the line is blank Using the keypad enter a label of up to 32 characters in length and then press the Enter button SenTRI2 fire system How to edit a zone label Each zone can be given a label and an entered label can be modified To edit a zone label you will need to know the zone number You can find this information in the site spec
37. trol and indicating equipment That any previously indicated fault conditions have received appropriate attention All system events are entered into the Log Book for future reference That the use of the area s that are inspected has not changed since the system was designed That no unsafe practices that could lead to fire are being undertaken Weekly When testing the system there may be a need to isolate ancillary outputs and it is important to contact the alarm receiving centre before and after the weekly test O A different manual call point of the system should be tested to ensure the system is capable of operating under alarm conditions O The operation of the alarm sounders should be checked which also reminds the occupants that there is a fire alarm system which gives a particular sound output The test should be performed at a regular time to avoid confusion between a test and a genuine fire alarm The alarm receiving centre must be contacted before and after the test to check alarms are received and also to avoid unwanted alarms SenTRI2 fire system Quarterly At quarterly intervals the system should be inspected and any work necessary should be performed by a trained maintenance engineer For help with service and maintenance please refer to your servicing organisation see contact details entered in the log book Limitation of false alarm It is recommended that the person responsibl
38. ult 0 The mains supply to the Control panel has failed Restore the mains supply to the control 1 or panel Battery 2 2 The battery supply to the Control Panel has been Check the battery and replace if P Fault discharged n Fault a fully discharged necessary Battery ote 2 The battery supply to the Control Panel has been Reconnect the battery P Fault Monitored line Fault er The monitored line input has an open or short Check the wiring and ensure the end of input OC or SC ore circuit fault line device is connected in the circuit Master Alarm s Fault O Sounder O There is an open or short circuit fault on the Check the wiring Ensure the end of line OC or SC n ore ore master alarm wiring device is connected in the circuit Lost Device Fault I Sounder O The Device is not communicating with the Check the connections to the device Control Panel via the Loop Additional indication given if it is a Sounder device Sensor out of Fault I The device indicated is not functioning correctly Device needs replacing specification 1 Wiring changed Fault hae There is a short circuit on the loop n wiring Identify the device where a cable fault SC at card n ae 1 has occurred and remove the fault Interface input There is an open or short circuit on the input line Locate and remove the wiring fault OC SC 7 of an interface Ensure the end of line device is connected in the circuit Device Main
39. utton b Press the F4 button to select Test Eng c Press the F4 button to select UserCode Use the keypad to input your existing access code and then press the Enter button d Press the F1 button to select NewPass At the flashing cursor using the keypad input the PIN code and press the Enter button Notice New access code set up appears on the display Any changes made to the PIN code must be backed up to the panel memory If this is not done then the previous PIN is restored on resetting the panel see section on How to save changes to memory It is not necessary to backup the password ata repeat panel How to view the historic events How to view the historic events Cards inside the control panel Up to 255 events are stored in the Historic log of the panel To The control panel uses the following card reference numbers view the Historic log a D 22 Press MENU ON OFF O Card 0 is always the Main controller board MCB also referred to as a local controller Press the F3 button to select Info Ignore step c if an external printer is not fitted or is switched off O Card 1 and Card 2 are always the Loop processor cards that monitor and control the devices on a loop circuit within To display the event s Press the F1 button to select the protected premises Display Notice Display appears on the display To print the event s Press the F2 button to select Print Not
40. w to use the external printe Assuming an external printer is connected to the panel To Switch On Off the Printer a Press the MENU ON OFF key b Press the F1 key to select Control c Press the F3 key to select Printer Check that Printer appears on the screen d Press the F3 key to select On Off and then press the F2 key to select Enter Printer is on off is displayed To action a Paper Feed a Press the MENU ON OFF key b Press the F1 key to select Control c Press the F3 key to select Printer Check that Printer appears on the screen d Press the F2 key to select Paper Fd Note the display and menu prompts are cleared Printer performs 8 line feeds To conduct a Printer Test a Press the MENU ON OFF key b Press the F1 key to select Control c Press the F3 key to select Printer Check that Printer appears on the screen d Press the F1 key to select Test Note the display and menu prompts are cleared e Check that the printer provides a listing of all the characters it is capable of printing SenTRI2 fire system How to enable disable Sensing A sensing device such as a sensor or MCP in the system can be disabled enabled You will need the device and loop numbers this information can be found in the site specific documents held by the person responsible for the fire system a Press the MENU ON OFF key It is only possible to disable a Manual Call Po
41. ystem Devices in your system may have already been given labels and these labels can be changed To edit a device label you will need to know the device number and the loop on which it resides You can find this information in the site specific documentation held by the person responsible for the fire system a Use the keypad to enter a label of up to 32 characters in length 28 for MCP and then press the Enter button How to edit an Input output line label Each input output lO line of an interface unit can be given a label and a previously entered label can be modified To edit an IO line label you will need to know the IO line number interface a Press the MENU ON OFF button device number and the loop number it is connected to You can b Press the F2 button to select Set Up find this information in the site specific documentation held by the person responsible for the fire alarm system C Press the F4 button to select UserCode A message Press the MENU ON OFF button is displayed Enter access code followed by a flashing cursor Use the keypad to input your PIN and then b Press the F2 button to select Set Up press the Enter button c Press the F4 button to select UserCode Notice a message d Press the F4 button once to select lt etc gt on the display Enter access code followed by a flashing e Press the F1 button to select Modify Notice Modify cursor Use the keypad to input your PIN and
Download Pdf Manuals
Related Search
Related Contents
KOHLER K-2238-4-7 Installation Guide User manual VERTU (jean) Yamaha DSP-AX757SE Stereo Receiver User Manual VW1101A VW2500A VW4432A USER MANUAL (Rev. 3.2) Infant Flow - CareFusion User manual Wapo-Ex - Wassermann Dental Multiple-interface selection system for computer peripherals StarTech.com 92x25mm Ball Bearing Quiet Computer Case Fan w/ TX3 Connector イタリアンセレクト照明 Triton T2 Manual de instrucciones Por favor, siga las sencillas Copyright © All rights reserved.