1. Description Cartridge management zone 1 Cartridge management zone 2 Cartridge management zone 3 8 HP Moonshot devices Cartridges HP ProLiant Moonshot Cartridge The HP ProLiant Moonshot Cartridge is a single node cartridge that can be installed in any of the 45 cartridge slots in the chassis 0 2 cS Lie tem Deseription O O Workload Direct hosting and limited web front end Processor One 2 0 GHz Intel Atom processor 2 cores 8 5 W non removable One 1333MHz DIMM DDR3 UDIMM SO DIMM ECC 8GB Onboard NIC 1 dual port 1GbE NIC per processor Storage SFF drive 500 GB 1 TB Direct from drive Network Operating Ubuntu 12 04 system Red Hat Enterprise Linux 6 4 SLES 11 service pack 2 Switch modules and uplink modules HP Moonshot 45G Switch Module The HP Moonshot 45G Switch Module is the internal partner to the external uplink module HP Moonshot devices 9 The switch module is installed inside the chassis and the uplink module is installed in the rear of the chassis The uplink module provides external access to the switch The switch module has the following key features High density low power Low latency switching performance 45 1GbE ports per switch module 6 10GbE uplink ports per switch module Dual switch modules provide traffic isolation or can be stacked for resiliency Rack level stacking to simplify management domain
2. A el LE TE B sl L em Deserpion CR TT 2 Jcmdgeron 2 Cartridge row 3 Switch module and uplink module population rules When populating switch modules and uplink modules always install the two as a pair The pairs are not required to be installed in any order as long as both the switch module and uplink module are in the same bay number e When installing a switch module in switch module bay A install the uplink module in uplink module bay A on the rear of the chassis e When installing a switch module in switch module bay B install the uplink module in uplink module bay B on the rear of the chassis The switch module and uplink module are companion devices and both are required for normal operation Configuration rules 17 e All slots must be populated with either a module or a blank Power supply population rules Two to four power supplies can be installed in the chassis The required number of power supplies varies depending on the configuration e A minimum of two power supplies is required to boot the chassis e A minimum of three power supplies is required to be redundant e A maximum of four power supplies can be installed in the chassis HP recommends using the HP Power Advisor to calculate the infrastructure required for your configuration and allow some flexibility for growth HP provides power sizing tools on the HP website http www hp com go hppoweradvisor Fan p
3. enhanced small form factor pluggable Acronyms and abbreviations 25 Documentation feedback HP is committed to providing documentation that meets your needs To help us improve the documentation send any errors suggestions or comments to Documentation Feedback mailto docsfeedback hp com Include the document title and part number version number or the URL when submitting your feedback Documentation feedback 26 Index A authorized reseller 24 before you contact HP 24 C cartridge slot numbering 7 cartridges 9 16 21 chassis components 6 7 chassis management 11 CMU 14 compatibility 14 19 20 configuration 16 configuration rules 16 17 18 contact information 24 contacting HP 24 CSR customer self repair 24 customer self repair CSR 24 D device mapping 21 devices identifying 6 documentation feedback 26 event logs 14 F fan population guidelines 18 fans 12 features 5 H hardware compatibility matrix 19 help resources 24 HP contact information 24 HP Insight Cluster Management Utility 14 HP Moonshot 1500 Chassis 6 HP Moonshot 1500 Chassis Management module 11 HP Moonshot Component Pack 15 HP Moonshot iLO Chassis Management Firmware 14 HP Moonshot 45G Switch Module 9 HP Moonshot 6SFP Uplink Module 10 HP ProLiant Moonshot Cartridge 9 21 HP technical support 24 HP website 24 HP contacting 24 iLO management zones 8 IML Integrated Management log 14 Integrated Manage
4. Configuration and management with two tools o HP Moonshot iLO Chassis Management Firmware o HP Moonshot45G Switch Module CLI Layer 2 Layer 3 routing and QoS Management CLI SNMP SFLOW No license keys required HP Moonshot 6SFP Uplink Module The HP Moonshot 6SFP Uplink Module is the external outlet partner to an internal switch module HP Moonshot devices 10 The switch module is installed inside the chassis and the uplink module is installed in the rear of the chassis The uplink module provides external access to the switch module The uplink module has the following key features e Six 1OGbE SFP uplink ports e LEDs that provide health and link information about the uplink module e Serial port for out of band management HP Moonshot 1500 Chassis Management Module The Moonshot 1500 CM module is the gateway for system and network management The Moonshot 1500 CM module has the following key features e Device neutral low cost node solution e IPMI and serial console for each server e Single Ethernet port gateway e HP Moonshot iLO CM Firmware which aggregates to a common set of management interfaces e SL APM rack management which spans rack or multiple racks e True outof band firmware update services e Service port to both switches for remote network management HP Moonshot devices 11 Power supplies Depending on the cartridges and switches installed two to four power supplies are required to
5. download the latest MCP from the HP website http www hp com go servers moonshot download Software tools and solutions 15 Configuration rules Basic configuration rules Chassis configuration rules are dependent on the models and quantities of cartridges and switches installed but consider the following basic rules e Fans must be installed in all fan bays e Sufficient power supplies must be installed to support the installed cartridges and switches e The internal switch module and external uplink module are a mated pair If two switch modules are installed two uplink modules are required e All internal and external slots and bays must be populated with modules or blanks for proper thermal cooling Cartridge population rules Cartridge configuration rules are maintained by the chassis as each cartridge reports its model information to the Moonshot 1500 CM module When installing cartridges in the chassis always populate the cartridge slots in rows beginning in row 1 slot 1 Completely populate row 1 populate row 2 and then populate row 3 If the chassis is powered on when adding cartridges e Cartridges must be installed one at a time Configuration rules 16 e Elapsed time between removing the blank and installing the cartridge must not exceed 30 seconds zA Ji EE B 8 fe ae eee hr nn i E z if E 5 mes VE
6. power the chassis For more information see Power supply population rules on page 18 The HP 1200W Common Slot Platinum Plus Hot Plug Power Supply supports the following e Common slot design e Power management for redundant power configurations Fans Five fans ship standard with the chassis At all times all five fans must be installed To boot and run the chassis all five fans must be installed and operating For more information see Fan population rules on page 18 If a fan fails during operation after flashing a red LED iLO automatically initiates a graceful shutdown of all cartridges Each fan module has the following key features e Common slot design HP Moonshot devices 12 Two rotors HP Moonshot devices 13 Software tools and solutions Product QuickSpecs For more information about product features specifications options configurations and compatibility see the product QuickSpecs on the HP Product Bulletin website http www hp com go productbulletin HP Moonshot iLO Chassis Management Firmware Moonshot iLO CM firmware is the gateway for aggregated chassis management on HP Moonshot The iLO CM firmware reduces cost and power by sharing four iLOs across the nodes and other Moonshot components As a single point of access to the chassis iLO CM firmware allows you to configure update and operate HP Moonshot through CLI IPMI and remote serial console access For more informat
7. E 12 FA bee emia 14 Product QUICKS PEGS AR ra R E EEEE te cs je edge E EES EEE 14 HP Moonshot iLO Chassis Management Firmware 14 HP Moonshot iLO CM Integrated Management Log 14 HP Moonshot iLO CM Event Los swan tidouava nasdenantyieodtia uesdbaontenelanisacosanylenteaneacnss 14 HP Insight Cluster Management Wily ne om naamnananontannmecandee 14 HP Moonshot Component Pack sise 15 OR Di D ie be Un 16 ee Le and onda nn noie 16 Cartridge WOU ANCE FIGS vu 16 Switch module and uplink module population rules ss 17 Power supply population rules sise 18 Fan population rules cccccccsessssessessceeesseeeeeceseeeeeceseeeeseeeeeeeeeseeeeesceseaeeeceaaeeeseeanaeeseeseaeescesaaeeessesuaeeseeaaa 18 KST SEERE EESE EESPERE EEEE 19 Hardware compatibility matrix sise 19 EEE 20 Software compatibility matrix iii 20 Dece CELE EEE een ne te NE ere te eee eer ee ee 21 HP ProLiant Moonshot Cartridge mapping cceccsisnsssnceceeseasanedanvaaieacseamnsanteaaieacassomauancaneceaiesigiauacceaxqeaone eaves 21 Seer Ore aher PRE 24 Before you Contact HP cccccccesccccesesccceeceseeeeeceseeeeeeeeeeeeeeeeseeeeeceseeeeseeeseeeecesaeeeecesseeecesseeeesecesaeeseseseeeeeaas 24 HP contact THING MANONe RUE ee ln nindei ler ner een ent Neue 24 Customer self repair iii 24 Pos one Gt Ia EE A A 25 Deanne ee TG EE EE 26 OE EEE EE E A NENNE 27 Contents 3 Contents 4 Introduction HP Moonshot overview HP Moonshot is a super high density po
8. HP Moonshot Configuration and Compatibility Guide Abstract This guide describes HP Moonshot hardware configuration options and hardware and software compatibility rules HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels Part Number 711768 001 April 2013 Edition 1 Copyright 2013 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Intel is a trademark of Intel Corporation in the United States and other countries Contents ee ONO 5 FAP Moons NOE OVINE EE NE RE S AEROS TE EE SENE ne ts int ee 5 E EE re RE EEE ET E AE EE NO TA O E 6 HP Moonsh t T500 Chassis asss see cn nano T E EEEE tn 6 Cartridge slot and switch module bay identification 7 Management ZONES sevei is i E dativ E EE VE EE SE E E SEE OSEE 8 Ga 10 RE RE ER EE ER E E Eee ae 9 HP Proliant Moonshot leveres 9 Switch modules and uplink modules 9 HP Moonshot 45G Switch Module Les 9 HP Moonshot 6SFP Uplink Module sisi 10 HP Moonshot 1500 Chassis Management Module denssehennte 11 Powers 12 PEER NE REE ES E
9. artridge mapping Each HP ProLiant Moonshot Cartridge has two ports with each port connecting to one of the internal network switch modules and its corresponding uplink module Understanding the software enumeration of Ethernet ports and the linkage to NIC network hardware helps ensure that the network is properly configured and aids in troubleshooting Device mapping 21 The following image shows the networking layout with each cartridge and uplink module labeled with the unit slot port naming convention The ID numbers shown in the image reference physical entities such as cartridge slots and ports by using a unit slot port naming convention e Unit The stack member within a stack of switch modules e Slot The port location or type o 0 o l a physical internal port a physical external port Device mapping 22 o 3 a logical LAG port o 4 a logical VLAN routing interface e Port A specific physical port or logical interface being managed by a given slot o Physical ports for each slot are numbered sequentially beginning with 1 o LAG port numbers range from 1 to the maximum number of LAGs that the switch module supports To determine the port mapping ID for a specific cartridge determine the cartridge slot number and use the following table Cartridge slot number OS device name Conn
10. e Linux clusters A simple graphical interface enables an at a glance view of the entire cluster across multiple metrics provides frictionless scalable remote management and analysis and allows rapid software provisioning to all system nodes HP Insight CMU makes cluster management more user friendly efficient and error free than if it were being managed by scripts or on a node by node basis HP Insight CMU is highly flexible and customizable offers both GUI and CLI interfaces and is used to deploy a range Software tools and solutions 14 of software environments from simple compute farms to highly customized application specific configurations For more information on HP Insight CMU features and links to technical documentation Quickspecs and a product demo see the HP website http www hp com go cmu To download the product go to the HP Software Depot https h20392 www2 hp com portal swdepot index do Click HP Insight Management then click Insight Cluster Management HP Moonshot Component Pack MCP is a comprehensive firmware solution delivered as a single file The solution is tested on the HP Moonshot and is delivered as a family of bundles The MCP deploys firmware updates through a CLI that flashes the firmware components Flashing the firmware components consists of delivering an update file to the iLO CM firmware which distributes the flash file as appropriate If you cannot be connected to the Internet during the setup
11. ects to internal Connects to external uplink switch module module port lt cartridge slot number gt Switch module A port Uplink module A any port 1 0 lt cartridge slot number gt lt cartridge slot number gt Switch module B port Uplink module B any port 1 0 lt cartridge slot number gt The following table provides specific examples using cartridge slot numbers 24 and 45 Cartridge slot number OS device name Connects to internal Connects to external uplink network switch module port 24 ethO Switch module A port Uplink module A any port 1 0 24 1 0 24 1 0 45 1 0 45 Device mapping 23 Support and other resources Before you contact HP Be sure to have the following information available before you call HP e Technical support registration number if applicable e Product name e Chassis serial number e Product identification number e Applicable error messages e Operating system type and revision level To obtain product information log in to iLO CM firmware and use the Show Chassis Info command For more information see the HP Moonshot iLO Chassis Management Firmware User Guide in the HP Moonshot Information Library http www hp com go moonshot docs HP contact information For United States and worldwide contact information see the Contact HP website http www hp com go assistance In the United States e To contact HP by phone call 1 800 334 5144 For continuous quality improvement call
12. ion see the HP Moonshot iLO Chassis Management Firmware User Guide in the HP Moonshot Information Library http www hp com go moonshot docs HP Moonshot iLO CM Integrated Management Log The iLO CM IML records hundreds of events and stores them in an easy to view form The iLO CM IML timestamps each event with 1 minute granularity To view recorded events in the iLO CM IML use the show log iml command in iLO CM firmware To save the log cut and paste the content from the session window or set session logging in the SSH client For more information see the HP Moonshot iLO Chassis Management Firmware User Guide in the HP Moonshot Information Library http www hp com go moonshot docs HP Moonshot iLO CM Event Log The iLO CM Event Log is an operating system independent log that maintains a record of events by date and time Logged events include major events such as a power outage or a reset and iLO CM firmware events To view recorded events in the iLO CM Event Log use the show log ilo command in iLO CM firmware To save the log cut and paste the content from the session window or set session logging in the SSH client For more information see the HP Moonshot iLO Chassis Management Firmware User Guide in the HP Moonshot Information Library http www hp com go moonshot docs HP Insight Cluster Management Utility HP Insight CMU is an efficient and robust hyperscale cluster lifecycle management framework and suite of tools for larg
13. ment Log IML 14 introduction 5 M management zones 8 O options 14 overview 5 P phone numbers 24 population guidelines 16 power supplies 12 18 product features 14 product overview 5 Q QuickSpecs 14 R required information 24 resources 24 S software 14 software compatibility matrix 20 Index 27 software resources 14 support 24 support and other resources 24 switch module 9 17 switch module bay numbering 7 T technical support 24 telephone numbers 24 U uplink module 9 10 17 utilities 14 W website HP 24 Index 28
14. opulation rules Five fans ship standard with the chassis Each fan contains two rotors e To boot and run the chassis a minimum of five fans must be installed with at least nine operational rotors e For a redundant configuration all five fans 10 rotors must be installed and operating Configuration rules 18 Hardware compatibility Hardware compatibility matrix The following hardware is supported in the HP Moonshot 1500 Chassis e HP Proliant Moonshot Cartridges Up to 45 cartridges per chassis e HP Moonshot 1500 Chassis Management Module One module required per chassis e HP Moonshot 45G Switch Module Up to two switch modules per chassis when paired with supported uplink modules e HP Moonshot 6SFP Uplink Module Up to two uplink modules when paired with supported switch modules e HP 1200W Common Slot Hot Plug Power Supply At least two power supplies per chassis e Fans Five fans required per chassis Hardware compatibility 19 Software compatibility Software compatibility matrix Supported and tested companion firmware and software must be installed on Moonshot components For more information about updating firmware on Moonshot components see HP Moonshot Component Pack on page 15 For information about operating systems supported by HP Moonshot see the operating system support matrices http www hp com go supportos Software compatibility 20 Device mapping HP ProLiant Moonshot C
15. s may be recorded or monitored e If you have purchased a Care Pack service upgrade see the Support amp Drivers website http wwwB8 hp com us en support drivers html If the problem cannot be resolved at the website call 1 800 633 3600 For more information about Care Packs see the HP website http pro agq sama houston hp com services cache 10950 0 0 225 121 html Customer self repair What is customer self repair HP s customer self repair program offers you the fastest service under either warranty or contract It enables HP to ship replacement parts directly to you so that you can replace them Using this program you can replace parts at your own convenience A convenient easy to use program e An HP support specialist will diagnose and assess whether a replacement part is required to address a system problem The specialist will also determine whether you can replace the part e For specific information about customer replaceable parts refer to the maintenance and service guide on the HP website http www hp com support Support and other resources 24 Acronyms and abbreviations CM chassis management CMU HP Insight Cluster Management Utility CSR Customer Self Repair iLO Integrated Lights Out IPMI Intelligent Platform Management Interface LAG link aggregation group MCP HP Moonshot Component Pack MIB management information base SATA serial ATA SFF small form factor SFP
16. wer and cooling optimized system housed in a 4 3U chassis HP Moonshot is built using the following system components e Chassis e Cartridges e Switch modules and uplink modules e HP Moonshot 1500 Chassis Management module e Fans e Power supplies As described in this document configurations vary depending on the cartridges and switches installed Introduction 5 HP Moonshot devices HP Moonshot 1500 Chassis The HP Moonshot 1500 Chassis is a 4 3U rack mounted chassis Switch module and uplink module pairs fons o O Fans Component nues Mai z Dependent on the configuration The system backplane on the bottom of the chassis identifies the installed cartridge model and switch module model information and routes communications from the cartridges to the internal switch modules which is then available through the external uplink modules For more information about these mappings see Device mapping on page 21 HP Moonshot devices 6 Cartridge slot and switch module bay identification The chassis provides 45 cartridge slots 1 45 and two switch module bays A B HP Moonshot devices 7 Management zones For some management tasks the cartridge slots are divided into three management zones