Home
Preview - HWAM North America
Contents
1. between the glass and the inner door frame You may also need to install a third gasket between the inner and outer door frames if the gasket is worn or damaged Lift up the door Place the door on a soft pad Loosen the fastening screws that hold the inside door frame Remove the door frame and carefully remove the remainder of the old glass Make note of the locations of the gaskets 4 Clean the area where the glass and gasket are to be installed 5 Install the new flat self adhesive gasket on the edge of the inside surface of the outer door frame around the opening and cut off surplus gasket to make an air tight joint The side with the adhesive is to fix the gasket to the inside of the outer door frame 6 Carefully place the glass on the outer door frame and remember to install the two circular glass holders on the top part of the door Install the second new self adhesive gasket on the inside of the bottom and sides of the glass This must be installed so there is no gap between the glass and inner door frame Do not install gasket along the top This is the location of the air wash Then install the inner door frame using the screws removed in disassembly 7 f you need to replace the gasket between the inner and outer door frames use your fingers or a screwdriver to push the flat part of the cord in between the inner and outer door frame Make sure the cord is not pushed in so far that the round part will not seal against
2. firing and cleaning Refueling the Stove When there are no more visible yellow flames and a bed of embers covers the bottom of the stove you can add more wood Place at least two logs weighing up to 1 kg or 2 3 lbs each in the stove If you place only one log the fire may burn inefficiently causing a loss of heat and increasing soot on the glass E2 After refueling the stove you may adjust the air wash control to the middle position When in continuous use no further adjusting is necessary This is done automatically However the temperature can be adjusted up or down by the air control rod 1 Moving the rod to the left reduces burning and prolongs the burning time Moving the rod to the right rises the temperature and reduces the burning time When both controls are in the middle position the highest efficiency is achieved Postpone every new firing till the ember bed is suitably low Page 23 6 Maintenance Ash Disposal and Removal Caution Make sure the fire is out and stove is cold before removing ashes Never burn your stove with the ash drawer open Be careful when you remove ashes from the stove there may be embers left as long as 24 hours after the stove was last used Ashes should be placed in a metal container with a tight fitting lid and moved outdoors immediately Other waste should not be placed in this container The closed container of ashes should be places on a noncombustible floor or on the ground well awa
3. in 50 8 mm Chimney section 1 in 25 4 mm air space to chimney length Chimney connector 1213 Chimney connector Air space 2 in 50 8 mm Chimney length Masony chimney Sheet steel supports Page 13 Notes 1 Connectors to a masonry chimney excepting method B shall extend in one continuous section through the wall pass through system and the chimney wall to but not past the inner flue liner face 2 Achimney connector shall not pass through an attic or roof space closet or similar concealed space or a floor or ceiling Chimney height requirements The chimney must extend 3 feet above the level of roof penetration and a minimum of 2 feet higher than any roof surface within 10 feet Check with your local building officials for additional requirements for your area The condition of the chimney and height is very important we suggest a total minimum height of 15 4 5m Measured From the floor level on which the stove is installed Page 14 NOTE This page intentionally blank Page 15 3 Check the loose parts Before the stove is installed you must ensure that all loose parts are fitted correctly especially the baffle plate 9 Drawing B1 HWAM Monet Drawing B2 HWAM Monet with cooking section These numbers correspond to the numbers on the drawing on the opposite page gt Side plates 1 5 see the drawing below opposite Smoke shel
4. 08 W C Page 7 Draft Requirements cont The chimney draft depends on the weather conditions In stormy weather you may reduce the chimney draft by closing the damper in the smoke pipe if a damper has been installed If the chimney draft is strong the combustion air supply should also be reduced Chimney Installation Do not connect this unit to a chimney flue serving another appliance Do not connect to any air distribution duct or system HWAM Monet is listed for installation as a vertically top or rear vented wood burning stove using a listed class A UL103HT for Canada CAN ULC S629 factory built chimney exiting through the ceiling attic roof The inside diameter of the chimney connector pipe must not be smaller than 6 152 cm diameter Single wall 24 gauge MSG 0 58 0 71 mm and adapter must not be smaller than 6 152 mm this may be used in the room where the stove is installed follow the chimney manufacturer s instruction for installation of chimney and chimney adapter In Canada where passage through wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 Factory Built Chimney When a metal prefabricated chimney is used the manufacturer s installation instructions must be followed You must also purchase from the same manufacturer and install the ceiling support package or wall pass through and T section package fire stops where needed insulation sh
5. F 754 C This temperature is well above the temperatures in which you operate your stove This stove is designed to provide a flow of air over the inside of the glass This air combined with high temperatures helps keep the glass optimally clean when the air wash air intake is fully opened When operating the stove on low for extended periods of time the glass may become dirty A short hot fire will help clean off much of the normal soot buildup see section 6 Troubleshooting In order to keep glass soot free the moisture content of the wood must be between 15 and 18 Smoke Detectors HWAM strongly recommends installing smoke detectors throughout your home However do not install them too close to the stove as the heat can activate them Gaskets The stoves are equipped with ceramic gaskets to ensure the tightness of the doors and the glass These gaskets are wearing parts and must be changed from time to time Please consult your authorized dealer in this case Protected Wall Reduced Clearances Local codes in some areas will allow reduced clearances when the stove is installed adjacent to a protected wall system Your local building official must approve the variance Check your local building codes or with a qualified installer Page 20 Room Ventilation amp Combustion Air Supply Provide for an adequate supply of air for combustion Proper ventilation is essential when using a solid fuel burning appliance The combustion process us
6. FILIO intelligent heat HWAM Monet and HWAM Monet H Wood Stove User s Manual and Installation Guide HWAM Monet with soapstone HWAM Monet H with soapstone and wood compartment drawer and baking door This manual covers all versions of the HWAM Monet and the HWAM Monet H Manufactured by HWAM AS Nydamsvej 53 Herning 8362 Denmark TEL 45 86 92 18 33 Web Site www hwam com Distributed in the United States and Canada by HWAM North America 211 Reservoir Rd Plymouth New Hampshire 03264 TEL 603 236 7045 www hwamna com Table of Contents 12 3 5 uu iiit none E Let 3 2 Installation 4 ette on el ack 4 Pre Installation Check List 5 Clearance to combustibles 6 Floot protection iieri tee utet A aan 6 Ceiling Height 13 ie 6 Combustible Wall Clearance for top vent installation 6 Combustible Wall Clearance for rear vent installation 7 Draft Requirements nnn 7 Chimney Installation sesseeeeeeenn 8 Top vent installation 9 Chimney connection sssseseeeeenneenneen 9 Rear vent installation 10 Mounting the connector pipe 11 Combustible wall pass throughs 11 Chimney height re
7. air space When fastening supports to chimney length do not penetrate the chimney liner the inside wall of the Solid Pak chimney The inner end of the Solid Pak chimney section shall be flush with the inside of the masonry chimney flue and sealed with a non water soluble refractory cement Use this cement to also seal to the brick masonry penetration Minimum chimney clearance from masony to sheet steel supports and combustibles 2 in 50 8 mm Minimum clearance 9 in 228 6 mm of brick Chimney connector Factory built Nonsoluble chimney length refractory flush with inside of flu Use chimney Air space 9 in gt parts to attach 228 6 mm min 88 connector securel y Solid insulated listed le eap Masony chimney factory built chimney length Sheet steel suppo rts Page 12 Method 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 in 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insulation from the outer surface of the wall thimble to wall combustibles Support the wall thimble and cover its opening with a 24 gage minimum sheet metal support Maintain the 6 152 4 mm space There should also be a support sized to fit and hold the metal chimney connect
8. ces volatile substances Do not store wood within the installation clearances or within the space required for refueling or ash removal Warning Burning materials other than natural dry well seasoned wood may shorten the life of your stove and possibly lead to a dangerous over firing condition Do not burn garbage particle board scraps or pressed logs using bonding agents because they can produce conditions which will deteriorate metal Over firing the stove may cause paint discoloration A white glaze on the glass is an indication of over firing Page 22 Starting the Stove Do not elevate the fire on a grate Build fire directly on the hearth inside the stove El 0000 000 gt 2 1 The air control rod 1 is pushed farthest to the right and the air wash control in or under the door 2 is opened completely Place 2 fire lighters at the bottom On top of this place an amount of split kindling wood equivalent to two logs approx 4 Ibs or 2 kg Now light up Keep the door slightly opened until there is no more condensation approx 5 10 minutes Shut the door When all the kindling have caught fire the regulation rod 1 is pushed in the middle position Let the kindling burn until there are no more visible flames Warning Do not open the ash pan when lighting up and always keep it closed when the stove is in use otherwise you may damage or destroy the automatic control Open the stove door only during lighting re
9. e This is a 3 mm thick iron plate It is placed on top of the shaking grate and prevents the embers from falling into the ash pan The cover plate is raised approx 8 mm above the grate thus ensuring that the automatically controlled primary combustion air is distributed evenly at the base of the combustion chamber RE T Cross section view of cover plate and shaker grate Page 16 10 11 1 B2 HWAM Monet HWAM Monet H 1 Side plates Exploded view of the Skamol re 2 Smoke Shelf fractory plates Skamol is a very 3 Bottom plates heat resistant and highly insulat 4 Front plate ing material made of processed 5 Back plate vermiculite This material is ca pable of service temperatures up to 1150 C 2101 F It is however somewhat fragile Care should be used when handling these pieces and when fueling the stove Page 17 Handle The handle for the door is removable Please take notice that it will fall out when the door is closed F Handle f Loose handles Drawing H The handle on the door may loosen slightly after being used for some time If this happens it can be easily tightened again Loosen the pointed screw 1 on the lower side of the handle with a 2 5 mm Allen key Then tighten the central screw 2 on the handle with a 4 m
10. e 3 screws Screw the 3 screws through the holes in the pipe so the pipe cannot be lifted of turned from the stove Page 11 Combustible Wall Chimney Connector Pass Throughs Method A 12 304 8 mm Clearance to Combustible Wall Member Using a minimum thickness 3 5 89 mm brick and a 5 8 15 9 mm minimum wall thickness clay liner construct a wall pass through The clay liner must conform to ASTM C315 Standard Specification for Clay Fire Linings or its equivalent Keep a minimum of 12 304 8 mm of brick masonry between the clay liner and wall combustibles The clay liner shall run from the brick masonry outer surface to the inner surface of the chimney flue liner but not past the inner surface Firmly grout or cement the clay liner in place to the chimney flue liner Minimum chimng clearance to brick and combustibles 2 in 50 8 mm Minimum clearance t 12 in 304 8 mm of brick Chimney flue Chimney connector Minimum 12 in 304 8 mm Fire clay liner to combustibles Masony chimney Method B 9 228 6 mm Clearance to Combustible Wall Member Using a 6 152 4 mm inside diameter listed factory built Solid Pak chimney section with insulation of 1 25 4 mm or more build a wall pass through with a minimum 9 228 6 mm air space between the outer wall of the chimney length and wall combustibles Use sheet metal supports fastened securely to wall surfaces on all sides to maintain the 9 228 6 mm
11. es oxygen from inside the dwelling and if there is not adequate make up air Such as in newer homes which are well insulated and weather tight it may be difficult to obtain an adequate draft in your chimney caused by a shortage of air in the house To correct this it may be necessary to crack a window on the windward side of the dwelling or provide combustion air to a nearby floor wall vent fresh air duct or directly to the stove Please refer to your local building codes Draft Requirements The HWAM wood burning stove is only one component of the total system The venting system is equally important for achieving the required flow of combustion air to the firebox and for safely removing unwanted combustion by products from the appliance If the venting system s design does not promote these ends the system may not function properly Poorly functioning venting systems may create performance problems as well as be a safety hazard i e an oversized chimney may result in less than optimum performance Installations into a large masonry chimney may require a liner to improve performance A draft test should read greater than 04 W C Inches Water Column and less than 08 W C The chimney draft also depends on the weather conditions In stormy weather you may reduce the chimney draft by closing the damper in the smoke pipe if a damper has been installed If the chimney draft is strong the combustion air supply should be reduced accordingl
12. f Must be placed on the rear edge of the Skamol Bottom plates Front plate Back plate Loose heat shield under the ash pan This can be used as a lid when the ash pan is removed for emptying Cover plate Should always cover the grate There is a drawer with a basket for kindling in HWAM Monet with drawer HWAM Monet H with drawer Baffle plate The HWAM wood burning stove has one baffle plate that must be installed in the upper firebox When in the proper position the rear edges of the baffle plates should touch the back wall of the firebox See the mainte nance section of this manual for additional information on removing baffle plates for cleaning and for drawings of fire box inclusive of baffle plates of the stove The baffle plate Is hung on 3 hooks under the top plate in Monet H The front middle hook has an extra bent flap as transport security This flap however is to be removed before mounting the stove Use a screwdriver to do this In stoves with cooking section the baffle plate is hung under the cooking section 10 Rear smoke outlet At the factory this is sealed with a cast cover plate and an internal cover plate The smoke outlet is therefore hidden behind the plate 11 Removable rear plate covering automatic controls This must always be mounted if the stove is placed next to a combustible wall Cover plate Your HWAM wood burning stove is supplied with a loose cover plate for the shaking grat
13. f adhesive gaskets fixed to the stove body 6 mm diameter washer to be placed between stove body and automatic system Slide gate assembly 6 mm screws Sensor system Aluminium plate within the Slide gate assembly Page 28 Doon ss oo Automatic Various spare parts Cords Gaskets Ash drawer Ash drawer black 22 0427 Ash drawer gray 22 0427gray Page 29
14. ield roof flashing chimney cap etc Maintain the proper clearance to the structure as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation Masonry Chimney Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed Refer to Combustible Wall Chimney Connector Pass Throughs on the following pages Page 8 Top vent installation Required installation components Chimney cap Multi purpose Insulated chimney Storm Collar Storm collar ashing Roof flashing Ceiling support box or joist shield fire stop spacer Chimney connector pipe i Attic Insulation Chimney connector adapter Chimney connection The chimney connector is a single or double walled pipe used to connect the stove to the chimney For use with the HWAM wood burning stoves the chimney connector T Firestop Assembly MUST be 6 in diameter with a minimum thickness of ipae 24 gauge black steel or 26 gauge blued steel Section Aluminum and galvanized steel pipe is not acceptable for use with the HWAM wood b
15. late the other way until it passes easily through the opening 1 Side plates 2 Baffle plate 2 3 Bottom plates 4 Front plate 5 Back plate Ls SS 4 3 1 5 pd Removal of the Skamol plates should follow in the numeric order and replacement should follow in the reverse order of the removal that is step 1 to 5 Warning Do not operate wood burning stove without baffle plates properly installed or warranty will be void Warning Do not use substitute materials Always use listed spare parts from HWAM A S Door Glass A glass cleaner designed for wood burning stoves is recommended for cleaning the glass The glass can also be cleaned by dipping a moist cloth or old newspaper in the cold ashes and use this to clean the glass Wipe with a dry cloth 1 Do not use abrasive cleaners 2 Do not let the door gasket get wet Do not abuse the glass by striking or slamming the door shut 3 Do not operate the stove with broken glass If the glass breaks then replace it promptly Use only replacement gasket listed for the door glass and ash drawer 4 Do not clean the glass when hot Warning The ashes should not get into contact with your skin Page 25 Replacing Door Glass The door must be removed from the stove before installing new glass When you replace the glass you need to install 2 sets of gaskets between the glass and the door One continuous gasket is between the glass and the outer door frame and another is
16. le wall connector pipe can be located not closer than 18 below a combustible ceiling Flashing From the factory the stove is prepared for top mounting of the flue collar but all HWAM wood burning stoves have an optional rear flue outlet therefore the flue collar can be fitted either on the top or at the rear as required Support Bracket Assembly Mounting the flue collar for rear outlet Remove the cover plate on the rear of the stove Reed Remove the inner cover plate The flue collar is fitted from the outside into the discharge hole of the firebox in such a way that the bracket is located on the inside Place the cover plate on top so that this is just under FS ELENA level with the top plate thereafter it is possible to mount Plate the external cover plate for at smooth look E m Tee amp Branch Rear venting into a masonry or steel chimney through Stovepipe Extension a thimble vent configuration or other than described Wall Support here must follow local codes or NFPA 211 or Wall with Clean Out CSA_B365 guidelines and methods 10 Required installation components Chimney cap Insulated chimney section Tee support bracket Chimney connector pipe Wall thimble Wall strap Mounting the connector pipe to the stove Pipe is placed in smoke outlet The 3 screws are screwed into the pipe to make a mark in the pipe Drill a 5 2 mm hole at the markings from th
17. lothing and furniture away Contact may cause skin burns Use gloves when stoking the fire Page 3 Warnings 5 Do not connect this stove to a chimney flue connected to another stove or appliance 6 Do not connect to any air distribution duct or system 7 Do not install in a mobile home 8 Be sure to allow an adequate source of fresh air into the room where the stove is operating 9 Do not operate the stove without the firebox refractory plates properly in stalled 10 Build fires directly on the refractory bottom plates inside the stove 11 Do not use grates irons or any other method to elevate the fire What to do if you have a chimney fire If you realize a chimney fire is occurring follow these steps Get everyone out of the house including yourself Call the fire department If you can do so without risk to yourself these additional steps may help save your home Remember however that homes are replace able lives are not Put a chimney fire extinguisher into the stove Close the air controls on the stove and the damper on the chimney connector Use a garden hose to spray down the roof not the chimney so the fire won t spread to the rest of the structure Once it s over call a CSIA Certified Chimney Sweep to inspect for damage Chimney fire damage and repair normally is covered by homeowner insurance policies 2 Installation Warning If your HWAM wood burning stove is not properly installed
18. m Allen key through the little hole inside the door Tighten the pointed screw 1 on the lower side of the handle BE RR RRS x oS 5555 Q x oS RRS e oS RR 2 RR 555 oS RRR SS eS RRS eS 2X 55 65555 eS Page 18 Automatic Control Drawing G Lift off the rear panel The starting point of the control arm should be checked The angle of the control arm on a cold stove is about 10 above horizontal It should move easily and bounce when you push it no matter if the stove is cold or hot As the temperature rises and falls it must move smoothly The slide gates must be dry and clean and slide together unhindered Control bars and slide gates may need to be lubricated with WD40 do not use oil 4 Instructions for use Ash Drawer The ash drawer located below the fuel door is designed to make cleaning easier by containing the ashes in a removable drawer Replace the gasket as necessary to ensure a tight seal Caution Do not operate the stove with the ash drawer open or ajar as this will produce extreme temperatures within the stove over firing and could result in a house fire Damage caused from over firing is not covered under the manufacturers limited warranty It will also clog the automatic control with ash and prevent it from working Ash Grate Above the ash drawer located in the floor of the fireb
19. operated and maintained a house fire may result For your safety follow all installation operation and maintenance directions Contact your local building officials for information on restrictions and installation requirements in your area Page 4 Pre Installation Check List Before you begin an installation review your plans check to see Your stove and chimney connector will be far enough from combustible material to meet all clearance requirements The floor protection is large enough and is constructed properly to meet all requirements You have all necessary permits from your local authorities Your local building official is the final authority for approving your installation as safe and in determining that it meets all local and state building and safety codes The metal label permanently attached to the back of every HWAM wood burning stove shows that it has been tested to current UL and ULC safety standards and gives the name of the testing laboratory Clearance and installation information is also printed on the label Local authorities will generally accept the label as evidence that when the stove is installed according to the information on the label and in this manual the installation meets codes and can be approved Codes vary in different areas Before starting the installation review your plans with the local building authority Your local dealer can provide any additional information needed This room hea
20. or See that the supports are fastened securely to wall surfaces on all sides Make sure fasteners used to secure the metal chimney connector do not penetrate chimney flue liner Minimum chimney clearance to sheet steel supports and combustibles 2 in 50 8 mm 2S Two air channels each 1 25 4 mm Chimney connector Two ventilated air channels each 1 in 25 4 mm Mini 6 in 152 4 Construction of sheet steel 010 mm i fiber insulation Chimney flue mm Masony chimn y Y Sheet steel supports Method D 2 50 8 mm Clearance to Combustible Wall Member Start with a solid pak listed factory built chimney section at least 12 304 mm long with insulation of 1 25 4 mm or more and an inside diameter of 8 2 inches 51 mm larger than the 6 152 4 mm chimney connector Use this as a pass through for a minimum 24 gage single wall steel chimney connector Keep solid pak section concentric with and spaced 1 25 4 mm off the chimney connector by way of sheet metal support plates at both ends of chimney section Cover opening with and support chimney section on both sides with 24 gage minimum sheet metal supports See that the supports are fastened securely to wall surfaces on all sides Make sure fasteners used to secure chimney flue liner do not penetrate the liner Minimum chimney clearance to Sheet steel sheet steel supports and combustibles Supports 2n 30 8 mm Minimum clearance 2
21. ox is a rotating ash grate to facilitate transferring ashes from the firebox into the ash drawer To operate this grate Page 19 pull and push the handle placed in front of the stove in and out several times Only operate stove with the loop handle pushed all the way in Baffle Plate The HWAM wood burning stove has one baffle plate that must be installed the upper firebox When in the proper position the rear edges of the baffle plates should touch the back wall of the firebox See the maintenance section of this manual for additional information on removing baffle plates for cleaning and for drawings of fire box inclusive of baffle plates of the stove see page 19 Skamol Skamol refractory plates are delivered in all HWAM wood burning stoves When mounting a baffle plate place it according to the description on page 19 Removing Baffle for Cleaning Make sure that it is placed symmetrically in the stove i e with even amounts of free air space on each side We recommend that you treat the Skamol refractory plates with care because it is a delicate material not covered by the limited warranty Small cracks may arise in the Skamol because from minor water content especially if the stove is overheated during the first fire These cracks do not influence the performance of the stove and are not covered by the limited warranty Glass The glass is a heat resistance ceramic glass that can withstand continuous temperatures to 1390
22. quirements seeeee 14 3 Check the loose parts 16 4 Instructions for use 19 Ash Drawer amp Ash Grate sse 19 Baffle Plates amp Skamol refractory 20 1485 bes TEE ER EEE eevee o 20 Smoke Detectors 20 Room Ventilation amp Draft requirements 21 Lec 22 Starting the stove ssesssssseeeeeeeneeeen een 23 Refueling the stove 23 6 Maintenance 1 cecidere ti eiie a Loco Les o ees 24 Removing Skamol smoke plate for cleaning 25 Replacing broken Door Glass 26 4 Troubleshooting Ae dte 27 Automatic Air Control System diagram 28 Spare part list oc Linie oe ere eee eee hanai 29 Page 2 As Introduction We welcome you as a new owner of a HWAM wood burning stove The HWAM wood burning stove is one of the finest in the world This manual will explain the installation operation and maintenance of the HWAM wood burning stove Please familiarize yourself with the owner s manual before operating your stove and save the manual for future reference Included are helpful hints and suggestions that will make the operation and maintenance of your new stove an easier and more enjoyable experience We offer ou
23. r continued support and guidance To help you achieve the maximum benefit and enjoyment from your HWAM wood burning stove Please read the entire manual carefully before you install and use your new HWAM wood burning stove Failure to follow instructions may result in property damage bodily injury or loss of life This manual contains important user information Keep this manual with the stove after installation is complete Safety and environmental testing HWAM Monet have been tested by OMNI Test Laboratories Inc of Beaverton Oregon and are safety listed by OMNI to UL 1482 ULC S627 and EPA certified The serial number is fixed to the stove and to the guarantee card If you need to contact the factory please refer to this serial number Items included With your HWAM wood burning stove you will find the following items 1 instruction and maintenance manual 1 guarantee card 1 oven mitten 1 set of screws for the flue collar Warnings 1 Keep ash drawer closed during firing in this stove Use a metal container with a tight fitting lid to dispose of ashes 2 Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this stove Keep all such liquids well away from the stove while it is in use 3 Do not burn garbage or flammable fluids such as gasoline naphtha or engine oil 4 The stove is hot while in operation Do not touch and keep children c
24. s to combustible materials must be kept Chimney connector type wall pipe 330 mm me mm na mm 533mm 216 mm 356 mm mm 13 21 85 14 wall pipe 330 mm s mm ps mm 533mm 191 mm 356mm 914 mm 13 21 7 5 14 36 Page 6 Fig 2 BIE A 1 i D c Combustible Wall Clearance for rear vent installation If the stove is to be placed at side and back walls of combustible materials the following clearances to combustible materials must be kept Wood burning stove model B sr 1 d Fig 3 Refer to the chimney connector manufacturer s instructions concerning installation of listed connector pipe wall thimble and chimney Draft Requirements HWAM Monet is only one component of the total system The venting system is equally important for achieving the required flow of combustion air to the firebox and for safely removing unwanted combustion by products from the appliance If the venting system s design does not promote these ends the system may not function properly Poorly functioning venting systems may create performance problems as well as be a safety hazard i e an oversized chimney may result in less than optimum performance Installations into a large masonry chimney may require a liner to improve performance A draft test should read greater than 04 W C Inches Water Column and less than
25. sized flue may not provide effective draft and a flue liner may be required Observe draft requirements Consult your dealer or qualified installer before final selection is made We advise you to leave enough room to enable cleaning between the stove and the wall Clearance to combustibles One of the main necessary precautions you must take when installing a stove is to leave sufficient space between the stove top sides back front and under stove pipes and any other material that can catch fire Floor protection If the stove is to be installed on a combustible floor the stove must be placed on a noncombustible hearth pad which extends 8 200mm measured from the legs beyond the stove sides and back and 18 455mm measured from side and back panels to the front See Fig 1 Floor protection a B c o Us ow cma 0 0 e j A Distance from the front ofthe stove to edge of floor protection Distance from the side of stove to the edge of the floor protection C Distance from rear of the stove to the edge of the floor protection D Distance from the opening into the burn chamber to the edge of the floor protection Ceiling height clearance Do not install in an alcove or confined space and do not install in a room with a ceiling high below 7 0 210 cm Combustible Wall Clearance for top vent installation In placing to stove the following clearance
26. ter must be connected to 1 a chimney complying with the requirements for Type HT chimneys in the standard for Chimneys Factory Built Residential Type and Building Heating Appliance UL 103 or 2 a code approved masonry chimney with a flue liner For any unresolved questions about installation in the USA refer to the national Fire Protection Association s publication ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appliances For installation in Canada refer to CSA CAN B365 Installation Code for Solid Fuel Burning Applications abd Equipment These standards are the basis for many national codes They are nationally recognized and are accepted by most local authorities Your local dealer or your local building official may have a copy of these regulations WARNING Check all local building and safety codes before installation The installation instructions and appropriate code requirements must be followed exactly and without compromise Alterations to the stove are not allowed Do not connect the stove to a chimney system serving another stove appliance or any air distribution duct Failure to follow these instructions will void the manufacturers warranty Page 5 NOTE If you plan to vent your stove into an existing masonry chimney have the chimney inspected by a local fire marshal or qualified installer Remember that the chimney and its location on the roof heavily influents the stoves performance An over
27. the door opening of the stove Tighten the screws evenly and gently around the frame enough to be sure the door gasket stays in place then fully tighten the screws On 7 Install the door on to the stove again in reverse order of dismounting see under 1 Make sure that the door and the latch work properly Creosote Formation and the Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates in the flue lining When ignited this creosote makes an extremely hot and dangerous fire The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if soot creosote and ash build up has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Page 26 7 Troubleshooting Smoke Insufficient chimney draft Check if the chimney has the right dimension Check if the smoke pipe or chimney is blocked Check if the chimney has the right height compared to the surroundings Wood with too high moisture content The wood burns too fast Are the air controls adjusted correctly according to the instructions Is the smoke deflector plate placed correctly Sooted glass Is the air wash air valve adjusted according to the ins
28. tructions Is the wood dry Glass has white haze This can be caused by faulty operation such as 1 Glass not cleaned sufficiently 2 Burning milk cartons newspaper advertising material etc 3 Burning unapproved fuels such as coke and the like which creates too much heat 4 Stoking with impregnated tree or pressed wallboard 5 Excess chimney draft 6 Burning with the ash pan open If the glass turns white or opaque and cannot be immediately cleaned it may have been permanently damaged The glass in the wood burning stove is a special ceramic glass that can withstand very high temperatures At high temperatures however the glass is very sensitive to chemicals Burning advertising materials newspapers impregnated wood etc can ruin the glass Should this occur a glass set is available which contains glass sealing compound and an installation guide Excessive creosote build up in chimney this is a symptom of poor combustion it may be caused by wet wood or insufficient draft The shaking grate is stuck Check if a piece of wood is stuck in the grate Is the control arm out of position The stove s surface turns gray Over heating please refer to the maintenance section The stove does not heat the wood is not dry The combustion energy is being used to dry the wood Page 27 Automatic Air Control Parts and Assembly Diagram 1 2 3 4 5 6 Sel
29. urning stove These materials cannot withstand the extreme temperatures of a wood fire and can give off toxic fumes when heated EE Ceiling Do not use the connector pipe as a chimney Stovepipe Support Each chimney connector or stove pipe section must be connected to the stove flue collar and to each other with the male crimped end toward the stove Page 9 This prevents any condensed or liquid creosote from running down the outside of the pipe or the stove top All joints including the flue collar connection must be secured with three sheet metal screws to ensure that the sections do not separate For the best performance the chimney connector should be as short and direct as possible with no more than two 90 degree elbows The maximum horizontal run is 36 and a recommended total length of connector pipe should not exceed 10 feet Always slope horizontal runs upward 14 per foot toward the chimney No part of the chimney connector may pass through an attic or roof space closet or other concealed space or through a floor ceiling All sections of the chimney connectors must be accessible for cleaning Where passage through a wall or partition of combustible construction is desired the installation must conform with NFPA 211 or CAN CSA B365 Rear vent installation For venting into a masonry or a back standing steel chim E RN esas _ gt Storm Collar ney through the top vent the top horizontal portion of a sing
30. y Page 21 5 Operation Warning Do not use gasoline lighter fluid kerosene other flammable liquids to start or freshen a fire in the stove keep all such liquids well away from the stove while it is in use Fueling the wood burning stove Your HWAM freestanding wood burning stove is designed for burning dry natural well seasoned wood only If your wood supply is not seasoned ask your authorized HWAM dealer where to obtain seasoned fuel in your area Wood should be stored in a dry place for at least two years before being used for fuel Some trees have very high moisture content and it is necessary to thoroughly dry the wood Cutting and splitting the wood can speed up the drying process then stacking it with both ends of the stick exposed More drying occurs through the end than through the sides even when the wood is split We recommend that the moisture content of the wood be between 15 18 If your wood sizzles or you see bubbles coming from the end of the logs the wood is not dry Green or uncured wood does not work well as fuel and can cause increased creosote buildups The value of green wood as a source of heat is limited Do not overload use kindling wood or mill ends for primary fuel as this may cause over firing Although feeding excessive amounts of fuel to the stove should be avoided it is important to supply it with sufficient fuel to maintain a moderately hot fire this is particularly important since burning wood produ
31. y from all combustible materials pending final disposal If ashes are disposed of by burial in soil or otherwise locally dispersed they should be kept in the closed container until all cinders have thoroughly cooled Cleaning Your Stove The stove is cleaned with a moist lint free cloth Senotherm spray color is available for repair of possible damage or scratches Your dealer has the right spray in the right color As there may be minor color differences it is recommended to repair larger areas with natural borders You will get the best result if the stove is repaired while it is hand warm if the stove is too hot the paint will be granular Remember to keep the area well ventilated when using the paint Over firing may cause some paint areas on black stoves to turn gray Do not use more wood than recommended Start a small fire after repairing paint to allow the paint to cure Keep the area well ventilated during this firing Soapstone The soapstone may be cleaned with fine sandpaper or a dry sponge Page 24 Removing the Skamol Smoke Plate and Refractory for Cleaning Make sure the fire is out and stove is cold before removing the smoke plate be careful when handling the plates they are made of a breakable material Hold the smoke plate 2 in place while removing the side plates 1 Tip the smoke plate upwards in the front until it is free of the wall plate 5 Turn the plate to a vertical position and pull it downwards Turn the p