Home

VANTAGE Plant Design Global Install Guide 2.2

image

Contents

1. v VANTAGE Plant Design Global Plant Design Global Install Guide Version 2 2 MA LAS LZ N Fanaa Copyright 1974 to 2003 AVEVA Solutions Limited glob22 man1 doc1 issue 140403 PLEASE NOTE AVEVA Solutions has a policy of continuing product development therefore the information contained in this document may be subject to change without notice AVEVA SOLUTIONS MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS DOCUMENT INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE While every effort has been made to verify the accuracy of this document AVEVA Solutions shall not be liable for errors contained herein or direct indirect special incidental or consequential damages in connection with the furnishing performance or use of this material This manual provides documentation relating to products to which you may not have access or which may not be licensed to you For further information on which Products are licensed to you please refer to your licence conditions Copyright 1997 through 2003 AVEVA Solutions Limited All rights reserved No part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of AVEVA Solutions The software programs described in this document are confidential infor
2. OK any confirmation forms which appear 2 On the File Download form select Run this program from its current location to install the program files directly from their current location for example the CD onto your hard disk Select the Run this program from its current location and say OK 3 This starts the InstallShield Wizard which will lead you through the rest of the installation process During the installation sequence follow the on screen instructions as they appear You will be given a choice between two levels of installation e Full installation Installs all available product components recommended for a new installation unless there are good reasons for restricting the options available to end users e Custom installation Presents you with a list of all available product components from which you can select those to be installed When prompted for a destination location you must specify the directory in which PDMS has already been installed The default is C aveva pdms11 5 InstallShield checks that there is sufficient disk space available before it starts and warns you if there is not When the process is complete you should move the PDMS Global start menu program s to the relevant ProfilesNAll Users directory so that Plant Design Global start menu programs can be run by all users See the VANTAGE PDMS Installation Guide You must be a System Administrator to do this VANTAGE Plant Design Globa
3. program created it when attempting to view manuals from the Start menu programs Explanation The manuals are viewed using Acrobat Reader which has not been installed on the machine Install Acrobat Reader from the AVEVA CD VANTAGE Plant Design Global 5 1 Installation Guide Version 2 2
4. same as for PDMS 11 5 See the VANTAGE PDMS Installation Guide 1 2 Software and Configuration The software requirement and configuration for Plant Design Global under Windows are the same as those for PDMS which should be installed and configured before installing Plant Design Global See the VANTAGE PDMS Installation Guide 1 3 The AVEVA Security File You must have the correct AVEVA license file before you can use Plant Design Global The file is controlled by the network security product called FLEXMAN The version required for PDMS Global 2 1 n or higher is FLEXMAN 3 1 or higher Please refer to the FLEXMAN Installation Guide supplied with this release if you need more information Global now requires licences for Hub and Satellites At the hub location each project daemon will take out a GLOBAL licence entry At each Satellite each project daemon will take out a GLOBALSAT licence VANTAGE Plant Design Global 1 1 Installation Guide Version 2 2 Introduction 1 2 VANTAGE Plant Design Global Installation Guide Version 2 2 2 Installation You need to be the System Administrator or a Free User to install Plant Design Global under Windows 2 1 Basic Installation To install Plant Design Global 1 Having loaded the installation CD or accessed the installation files via some other route select the product you want to install in this case Plant Design Global 2 2 then click INSTALL or otherwise run Setup exe
5. Reinstalling To remove installed components from your hard disk or to add additional components to an existing installation select Start gt Settings gt Control Panel and use the Add Remove Programs option in the usual way As an alternative procedure repeat Steps 1 to 3 of the installation sequence detailed in Section 2 1 The InstallShield Wizard will detect your existing installation and will give you the following options e Modify Displays the same list of options as the Custom installation see Chapter 2 Select new components to be added and or deselect any currently installed components to be removed e Repair Reinstalls all currently installed components to correct any corrupted files etc e Remove Removes all currently installed components VANTAGE Plant Design Global 4 5 Installation Guide Version 2 2 Uninstalling and Reinstalling VANTAGE Plant Design Global Installation Guide Version 2 2 5 Troubleshooting 5 1 Starting Plant Design Global under Windows Error The message form Could not load application variables appears when trying to enter Plant Design Global Explanation Plant Design Global has not been installed in the same directory as PDMS Uninstall the misplaced Plant Design Global Repeat the Plant Design Global installation and specify the correct directory 5 2 Viewing Manuals Error Windows cannot open this file iindex pdf To open this file Windows needs to know what
6. he service in a MS DOS window type DemonServiceSingle remove If for any reason the service will not start it is possible to run the service from a MS DOS window using demonServiceSingle debug This will assist in identifying the cause of the problem for example Project directory not set up Note that the debug option runs the service program from the current user whereas the service itself runs as a local system administrator If the service fails to start or does not run the daemon try running the batch file from a command MSDOS window first unset variables in your command window C globalservice singleds start ABC VANTAGE Plant Design Global Installation Guide Version 2 2 This may show what is causing the daemon to stop for example incorrect or missing variables 3 3 Multiple project service To install the multiple project service for a project ABC in a MS DOS window type DemonServiceMulti install location c globalService multids where the batch file multids bat is in the directory c globalService This will set all environment variables required to run the required projects Note that the location parameter specifies the file location of the batch file not the PDMS location name The sample batch file supplied in PDMSEXE should be customised for each machine See comments for the single project service above In order to add projects to or remove projects from the service the service must be stop
7. l 2 1 Installation Guide Version 2 2 Installation Note If InstallShield detects an existing Plant Design Global installation it will display the options for removing reinstalling the files rather than simply offering the standard installation options See Chapter 4 for further details 2 2 Configuring the Plant Design Global GUI The PDMS Applicationware files are stored in directories pointed to by the environment variable PMLLIB PDMS needs an index file called pml index to exist in each top level directory in the PMLLIB path The index file contains a list of all the PML files in the directory and all its subdirectories If you entered PDMS 11 5 before you installed Plant Design Global you will need to run the pmlscan utility supplied with PDMS to re index the Plant Design Global Applicationware files For example if your PDMSEXE directory is c aveva pdms11 5 and your PML files are stored in PDMSEXE PMLLIB give the commands cd d c aveva pdms11 5 pmiscan PMLLIB Note You must have write access to the PMLLIB directories so that pmlscan can create the pml index file When the index files have been created you can make the PMLLIB directories read only if required 2 3 The Global Daemon For details of starting the Global daemon see the VANTAGE Plant Design Global User Guide The Global daemon can be started as a background process but if you close the process or logout of the workstation on which you sta
8. mation and proprietary products of AVEVA Solutions or its licensors For details of AVEVA s worldwide sales and support offices see our website at http www aveva com AVEVA Solutions Ltd High Cross Madingley Road Cambridge CB3 OHB UK Contents 1 Introtuclol essa ans 1 1 Lil Hardware sem ale Wii aa a 1 1 1 2 Software and Configuration i 1 1 13 The AVEVA Security Files iir rft veo eid eet t ett ini 1 1 2 Installation LE 2 1 2 1 Basic Installation ea ec aacra leen ases Pose ea Lee Leur 2 1 2 2 Configuring the Plant Design Global GUI eeeeeeeeeeeeeeeeeeeeene 2 2 2 95 The Gl bal Dacmioniei email cec tatis Tr ta 2 2 3 Uninstalling and Reinstalling eeee eese 3 1 4 TIroubleshoolllhg oec pene bee Peneneneneneneneiereii adiit 5 1 4 1 Starting Plant Design Global under Windows 5 1 4 2 Viewing Manuals ii 5 1 VANTAGE Plant Design Global Installation Guide Version 2 2 VANTAGE Plant Design Global Management Installation Guide Version 2 2 1 Introduction Note Before you begin PDMS Version 11 5 must be installed and running on the current system This guide explains how to install Plant Design Global 2 2 as supplied by AVEVA Solutions Ltd on a CD onto a workstation which is running under the Windows operating system 1 1 Hardware The hardware and operating system requirements for Plant Design Global are the
9. ped and then restarted with a modified batch file The start commands in this batch file to start or stop the daemon use parameters Do not replace parameter 1 by an explicit start since this batch file is also used when stopping the service When using a service which interacts with the desktop see below individual daemons can be started using an iconised window if the MIN argument is used with the start command For example start iProject basi MIN c globalservice admind exe 1 sam service Note This command must be run from a directory located on the local machine for the service to install If it is executed from a mapped drive or UNC pathname then the service will not start when requested To remove the service in a MS DOS window type DemonServiceMulti remove If for any reason the service will not start it is possible to run the service from a MS DOS shell using DemonServiceMulti debug This will assist in identifying the cause of the problem for example Project directory not set up Note that the debug option runs the service program from the current user whereas the service itself runs as a Local system administrator VANTAGE Plant Design Global 3 3 Installation Guide Version 2 2 Installing the Global Daemon Services Note Ifthe installation is unsuccessful remove the service and install it again 3 4 VANTAGE Plant Design Global Installation Guide Version 2 2 4 Uninstalling and
10. required to run the service for the single project ABC Note that the location parameter specifies the file VANTAGE Plant Design Global 3 1 Installation Guide Version 2 2 Installing the Global Daemon Services location of the batch file not the PDMS location name The sample batch file supplied in PDMSEXE should be edited as follows Set the project variables correctly for the project Only ABC000 ABCPIC and ABCMAC variables are normally required Set PDMSEXE to the location of the globalService folder Set PDMSWK to a valid local directory e g c NTEMP Set USERNAME to globaldaemon Set LM LICENSE FILE to a valid licence e g 7152 server Set PATH to include the PDMSEXE location e If transfer of other data files is required see Transfer of Other data Section 3 8 6 of the Global User Manual then import IMPORT and export variables EXP_XYZ for export to location XYZ must also be set up Note Ifthe project is using Areas these will also need to be set along with the other project variables This command must be run from a directory located on the local machine for the service to install If it is executed from a mapped drive or UNC pathname then the service will not start when requested The command in this batch file to start or stop the daemon uses parameters Do not replace parameter 1 by an explicit start since this batch file is also used when stopping the service To remove t
11. rted the daemon the Global daemon will stop e The Global daemon can be started as a standard Windows Service in which case it is not necessary to remain logged in 2 2 VANTAGE Plant Design Global Installation Guide Version 2 2 3 Installing the Global Daemon Services The normal way of running the Global daemon is as a service The files required are in the folder GlobalService in the PDMSEXE folder and this folder must be copied to the local disk Two services are provided one for a single project and one for multiple projects Note The service normally runs as an administrator and does not inherit any variables from the user login This means that all variables required by the service must be set up in the batch file used by the service 3 1 Location of files To run the daemon as a service the project directory and the daemon files must be on a local drive since the service cannot map network drives A full installation of PDMS is not required but the following list of files must be available on the local machine admind exe dformd dll project files inc vir dat dop exe attlib dat message dat 3 2 Single Project Service To install a single project service for a project ABC in a MS DOS window type DemonServiceSingle install project ABC location c globalService singleds where the batch file singleds bat is in the folder c globalService This will set all environment variables

Download Pdf Manuals

image

Related Search

Related Contents

storagetek t10000 operator guide  PENTA EndoVisHD-42  Sanyo PLC-XT35 User's Manual  Issue 232 December 2010 ISSN 1466-6790 www.batc.co  LG Electronics WT1101CW Use and Care Manual  Schon 51911-W001 Installation Guide  NORME DI SICUREZZA SUGLI APPARECCHI SAFETY  Canon DC 210 User's Manual  AudioBox™ USB  Bradford-White Corp Water Heater EF User's Manual  