Home
Peltor™ DECT-Com II™
Contents
1. ONE TWO Stop at your preferred base number or auto see below Log on to the base by pressing the M button and return to listen only menu items by pressing briefly on the M button A voice confirmation LOGIN followed by BASE number GROUP 1 is given confirming that the portable unit is logged on to the base with the given number as a listener in the given group If AUTO is chosen the unit will log on to the base with the latest used base or the next available Notice If there is more than one DECT Com II system within range of each other the portable units could be pre designated to certain bases respectively Then if the choice AUTO the unit will log on to the first found of the pre designated bases For programming DECT Com II units a special PC software is needed Contact your Authorised DECT Com II Dealer 2 4 LOG IN TO OR OUT OF A CONFERENCE Up to 9 active speakers and additionally more than 40 listeners can be members in a DECT Com II conference on the same base at the same time They can be subdivided in up to 3 conferences with fewer members in each group 2 4 1 LOG IN AS A LISTEN ONLY CONFERENCE MEMBER A portable unit is initially logged in to a conference as a LISTEN ONLY member taking part in the DECT Com conference as a listener only A voice confirmation BASE number GROUP number with the actual conference number and group is given At any time it is possible
2. Peltor DECT Com II The Sound Solution User s manual for DECT Com Il DECT 1 8 GHz C PELTOR QUICK GUIDE Peltor DECT Com II Button Function M Switch DECT Com II unit on off Select function in the menu Increase the level of selected function Decrease the level of selected function M amp Switch DECT Com II unit on as base M amp Switch DECT Com II unit on as portable PTT1 Press twice to talk in conference 1 Press once to listen in conference 1 PTT2 Press twice to talk in group 2 Press once to listen in group 2 PTT for external device in upper connector PTT3 Press twice to talk in group 3 Press once to listen in group 3 PTT for external device in lower connector amp All call short simplex transmission For latest revised full user s instructions please see www 3m com peltorcomms on the Internet Look in section Rest of the world and find PDF LIBRARY where you can read or download multilingual information about the Peltor DECT Com II system Fig A Antenna oed Function indication ring Headset connector M Mode Up Down LED Light Emitting Diode PTT1 Push To Talk 1 PTT2 Push To Talk 2 PTT3 Push To Talk 3 Attachment clip INDEX 21 2 2 2 4 25 2 6 3 1 3 2 44 4 2 5 1 9 2 INTRODUCTION MAIN UNITS SWITCH A MAIN UNIT ON AND OFF BASE PORTABLE UNIT PORTABLE UNIT LOG IN TO OR OUT OF A CONFE
3. indicates that the external battery is in use Tighten the screw with a suitable tool Caution When tightening the screw do not use your fingernail it can be broken Fig 21 Fig 22 Fig 23 3 1 3 2 CHANGE OF BATTERIES IN EXTERNAL BATTERY CARRIER Remove the battery carrier according to figures above in the reversed order Fig 23 fig 22 fig 21 Caution When loosening the screw do not use your fingernail it can be broken Remove the batteries from the battery carrier DC2032 Place 3 or 6 charged batteries inside the battery carrier DC2032 NOTICE Check that the batteries are correctly mounted before closing the battery carrier Mount the battery carrier on the main unit according to the figures below voice message EXTERNAL BATTERY indicates that the external battery is in use 13 Tighten the screw with a suitable tool Caution When tightening the screw do not use your fingernail it can be broken 3 1 3 3 RECHARGEABLE BATTERIES IN EXTERNAL BATTERY CARRIER Any rechargeable batteries in the battery carrier DC2032 must be taken out to be charged with an appropriate external charger according to the batteries specification 3 2 FIXED MOUNTED POWER SUPPLY Any main unit which should not be portable carried around could preferably be placed in a fixed mounted power supply holder DC2068 for unlimited working time without charging or changing batteries Also the power supply holder may be used for fixed mount of
4. main units are delivered open for registration from factory and a DECT Com II system can be started directly out of the box by first starting a base portable unit as a base as described above and after that all portable units sequentially and continually as described above After the first turn off of the base unit the configuration of the system is fixed and all future change of any units has to be handled by your Authorised Peltor DECT Com II Dealer If your system is delivered pre registered in a certain configuration by your Authorised Peltor DECT Com II Dealer all future registration also has to be handled by your Authorised Peltor DECT Com II Dealer 2 3 6 SEARCH A BASE FROM A PORTABLE UNIT gt n BASE SELECTION MODE on a portable unit double press on the M button to enter BASE SEARCH MODE A voice confirmation SEARCHING is given repeatedly confirming that the unit is searching for active bases in range When a base is found a voice confirmation BASE number GROUP 1 is given To find more bases repeat this procedure again 2 3 7 SELECT ANOTHER BASE FROM A PORTABLE UNIT gt In VOLUME MODE on a portable unit in LISTEN MODE double press on the M button to enter BASE SELECTION MODE A voice confirmation BASE is given urging to select a base gt Press or to cycle through the numbers of available bases and an auto setting A voice confirmation is given for each available choice AUTO
5. main units in high or low temperatures below 5 C or above 45 C where NiMH batteries can not be charged Notice The Power Supply holder DC2068 will supply a main unit with sufficient power also in usage temperatures from 26 C to 55 C but it will only maintenance charge the internal rechargeable battery pack A main unit with a rechargeable NiMH battery pack DC2033 in good condition may also have enough power for serving the system properly during a short power outage NOTICE No other power source than the Peltor DECT Com Il mains adapter DC2061 included in the package at delivery may be used together with the power supply holder DC2068 It is equipped with exchangeable European UK and US type mains connectors for the input of 100 240 Volt AC 50 60 Hz 3 2 1 AUTOMATIC RESTART OF A BASE UNIT With the Connector Sealing Plug DC2078 it is possible to have a base unit which is fixed placed in a power supply DC2068 automatically restarted after a power failure Instead of a headset in the connector on top of the base unit the arm of the connector sealing plug is pressing on the M button of the main unit enabling automatic restart after shorter power outages 3 3 MAINS ADAPTER The mains adapter DC2061 is also available as a separate spare part It is equipped with exchangeable European UK and US type mains connectors for the input of 100 240 Volt AC 50 60 Hz and may replace a faulty mains adapter for a c
6. power on out of the box the base unit will allow any portable unit to log on See 2 2 4 MAKE A BASE UNIT READY FOR PORTABLES TO BE REGISTERED 2 At any next start up you will automatically be logged on to the base When the log on sequence is finished the LED on the unit is fixed green and a voice message BASE number GROUP 1 is given confirming that the portable unit is logged on as a listen only to the base and group with the given numbers I If no confirming message is given check that the base unit is switched on and in range Ifthe message WARNING SUBSCRIPTION EMPTY is given there is no base unit registered to log on to I fthe messages SIGNAL LOW OUT OF RANGE are given the portable unit has no connection with the base unit After approximately 20 seconds a message SEARCHING is given indicating that the unit is searching for a base unit You may be too far away from the base or the base unit is switched off When in contact with a base unit again a message BASE number GROUP 1 is given confirming that the unit is logged on to a base with the actual number 2 3 5 LOG ON A NEW PORTABLE UNIT TO A BASE If later another portable unit should be logged on to the base the actual base unit must be set in REGISTRATION MODE see 2 2 4 MAKE A BASE UNIT READY FOR PORTABLES TO BE REGISTERED The portable unit must be in SEARCH MODE see 2 3 6 SEARCH A BASE FROM A PORTABLE UNIT below Notice All
7. range always return to TALK MODE as soon as itis in range again See 2 4 4 AUTO TALK above 2 6 TECHNICAL INFORMATION MAIN UNITS DC2811 DC2812 DC2815 Frequency range 1880 1900 MHz Output power Max 250 mW average 10 mW portable 120 mW base Current consumption Base Portable unit as base typ 320 mA 4 portables system DC2812 DC2815 as portable typ 160 mA in talk mode Portable unit DC2811 40 mA listen only 60 mA talk mode Working range typ 250 m line of sight Battery life cycle With rechargeable battery approx 6 h base unit Peltor DC2033 approx 40 h portable unit With 6xAA additional 2100 approx 18 h base unit mAh NiMH batteries in DC2032 approx 18 h base unit Usage temperature 26 C to 55 C Storage temperature 55 C to 70 C without batteries Store batteries according to battery manufacturer s instructions Headset connector Peltor J11 type M9177 4 1 NEXUS TJT 102 3 POWER SUPPLY A main unit can generally be power supplied with a rechargeable battery pack DC2033 in the battery compartment The external battery carrier DC2032 for 6 or 3 type AA batteries can also be used to increase the usage time of the unit Also in low or high temperatures below 5 C or above 45 C where the NiMH batteries do not have full capacity a main unit can be continuously power supplied in a power supply holder DC2068 with a mains adapter DC2061 NOTICE See below concerning t
8. 0 seconds to deactivate VOLUME BOOST A voice confirmation NORMAL VOLUME is given when you have deactivated the function 2 5 1 2 VOX Voice operated transmission In simplex radio communication VOX normally means that reception of the incoming sound from the receiver is completely stopped when sound of a certain level reaches the microphone and switches the radio to transmission mode With the full duplex DECT Com II units VOX means a voice operated noise gate which can prevent from transmitting background noise up to a certain sound level from units where the user do not speak but can constantly all the time listen to the incoming sound from the conference gt In VOX MODE use the and buttons to set the VOX sensitivity There are 7 VOX settings OPEN 1 2 3 4 5 OFF where OPEN means constantly transmitting continuous full duplex and OFF means that you have to use a PTT button to transmit see 2 5 2 PTT A voice message indicates your selected choice Last used setting is remembered between sessions IMPORTANT If you are using a Peltor headset which has a microphone with ambient noise compensation always position the microphone very close to your lips max 3 millimetres for optimal VOX function 2 5 1 3 MICROPHONE One of four microphone types carbon electret dynamic or low impedance can be chosen by the user to adapt the amplification in the DECT Com unit to the electrical signal level of th
9. NIT ON AND OFF gt Switch a DECT Com II main unit on by pressing the M button In a headset connected to the headset connector on the unit a voice confirmation POWER ON or BASE POWER ON is given and the LED light emitting diode is flashing indicating that the unit is in SET UP MODE When a base unit is ready for use a voice message BASE GROUP 1 is given The LED on the unit is flashing slower When a portable unit is ready for use a voice message GROUP 1 is given The LED on the unit is lit Notice All units are always started in listen only mode in group 1 2 1 1 SWITCH A MAIN UNIT OFF gt Switch a unit off by pressing and holding the M button for approximately 2 seconds A voice confirmation POWER OFF is given the LED is unlit and the unit is turned off 2 2 BASE PORTABLE UNIT 2 2 1 SWITCH A BASE PORTABLE UNIT ON Switch a base unit on by pressing the M button In a headset connected in the headset connector on the unit a voice confirmation BASE POWER ON is given and the LED light emitting diode is flashing showing that the base unit is setting up the system Notice Initially a base portable unit is starting up as a base See also 2 2 3 ALTERNATIVE OPERATION MODES OF BASE PORTABLE UNITS below After approximately 20 seconds the system is ready and a voice message GROUP 1 is given The LED on the unit is flashing slower showing that the base unit is ready for use and portab
10. OPEAN DIRECTIVES 3M SVENSKA AB DECLARA QUE EL EQUIPO DESCRITO ABAJO CUMPLE CON LAS DISPOSICIONES DE LAS SIGUIENTES DIRECTIVAS EUROPEAS Type of product model DECT com II 1 8 GHz DC2811 12 15 Name of Manufacturer 3M Svenska AB Address Box 2341 Malmstensgatan 19 SE 331 02 Varnamo Sweden Telephone No 46 0 370 69 42 00 Telefax No 46 0 370 151 30 Directive s RTTE Radio equipment and telecommunications EN The RTTE Directive sets requirements for electromagnetic emission and immunity limits for electric electronic products liable to generate electromagnetic disturbance or the perfor mance of which are liable to be affected by such disturbance This equipment is in conformity with the provisions of Council Directive 1999 5 EC and where such is the case with the national standard transposing harmonised standard s No EN 301 406 EN 60950 EN 62311 This equipment is identical to the RTTE which is subject of EC certificate of conformity No G0M21005 3251 T 62 G0M21005 3251 E 12 issued by Eurofins ES La Directiva CEM establece los requisitos de emisi n electromagn tica y limites de in munidad para productos el ctricos electr nicos susceptibles de generar perturbaciones o cuyo rendimiento pueda verse afectado por dichas perturbaciones Este equipo est fabricado de conformidad con las disposiciones de la Directiva del Consejo 1999 5 EC y cuando corresponde con la norma nacional correspondiente a la s norma
11. RENCE MAIN UNITS CONTROLS TECHNICAL INFORMATION MAIN UNITS DC2811 DC2812 DC2815 POWER SUPPLY BATTERIES FIXED MOUNTED POWER SUPPLY ANTENNAS GENERAL ANTENNA OMNI DIRECTIONAL VEHICLE ANTENNA EXTENSION OF THE SYSTEM EXTERNAL EQUIPMENT REMOTE WIRELESS PTT ACCESSORIES AND SPARE PARTS APPROVALS WARRANT Y PROGRAMMING DECT Com II UNITS PELTOR DECT Com II 1 INTRODUCTION Peltor DECT Com II is a wireless duplex intercom system operating on the 1 8 GHz DECT frequencies which are license free in most countries The products in the Peltor DECT Com II family offer simple and efficient wireless duplex communication with up to 9 active users talking in full conference and additionally up to 40 listeners with possibility to quick break in to the conference Ina system with more than 9 users any listening participant can change from listening to speaking The earliest active speaker will then be degraded to a listener in the conference and any other listener can follow replacing active speakers in the order first in first out There are basically two versions of the DECT Com II main unit base portable units and portable units The portable units work via a base unit A base portable unit can be either used as base or portable alternatively Due to low power output and high frequency it is a short range communication system The nominal working range is approximately 250 metres outdoors in line of sight The
12. a electrical data Frequency range 1710 1990 MHz VSWR Typical 1 2 1 orless Gain Isotropic 5 dBi Compared to 4 wave 3 dB Polarisation Vertical Pattern Omni directional Impedance 50 Ohm Antenna mechanical data Whip length 138 mm Base length 20 mm Operating temp 40 to 80 C Material Stainless steel with plastic end tip Colour Black Magnet mechanical data Diameter 102 mm Height mounted 40 mm Cable coax detachable Length om Connector RSMA 9 EXTENSION OF THE SYSTEM The DECT Com II system may be extended by connecting external communication equipment a second connector other additional features Consult your Authorized Peltor DECT Com II Dealer for the following options 5 1 EXTERNAL EQUIPMENT The Extension Base Portable unit DC2815 is equipped with a connector for connecting external equipment like communication radios telephones etc 15 In the list of ACCESSORIES AND SPARE PARTS see below you will find adapter cables for some common communication radios a general telephone cable and a cable for ground mechanic 5 1 1 FURTHER EXTERNAL EQUIPMENT On demand Extension Base Portable unit DC2815 can be equipped with a second connector to further improve the system by connecting even more external equipment This option implies some extra delivery time 5 2 REMOTE WIRELESS PTT The Peltor wireless PTT transmitter unit WLTX B allows remote control of PTT functions on the main unit This option im
13. ashing red green LED indicates that the charger unit is detecting analysing a newly inserted battery 3 1 2 1 TECHNICAL DATA CHARGER HOLDER DC2064 Input voltage 9 V DC Charging time of DC2033 in a main unit Up to approximately 12 hours Charging temperature interval 5 C to 45 C NOTICE No other power source than the Peltor DECT Com II mains adapter DC2061 included in the package at delivery may be used together with the charger holder DC2064 It is equipped with exchangeable European UK and US type mains connectors for the input of 100 240 Volt AC 50 60 Hz 3 1 3 EXTERNAL BATTERY CARRIER The external battery carrier DC2032 can be mounted on the back of the main unit It offers extra energy for longer usage time Any standard batteries 6 x 1 5 Volts type AA or rechargeable batteries 6 x 1 2 Volts type AA can be used Notice It is recommended to extend working time of a main unit used as a portable base by adding extra energy from batteries in a battery carrier 3 1 3 1 MOUNTING OF EXTERNAL BATTERY CARRIER Remove the attachment clip DC2071 if itis mounted on the back of the main unit Open the lid and place 3 or 6 batteries inside the battery carrier DC2032 according to the figures below Fig 11 Fig 12 Fig 13 NOTICE Check that the batteries are correctly mounted before closing the battery carrier Mount the battery carrier on the main unit according to the figures below voice message EXTERNAL BATTERY
14. base when switching off a voice confirmation WARNING POWER OFF is given 2 3 3 REGISTER A PORTABLE UNIT ON A BASE Each portable unit is registered to at least one base unit to be part of a DECT Com Il conference The unit is searching for bases voice message SEARCHING is given With the portable unit in LISTEN ONLY and VOLUME MODE double press M button to enter BASE SELECT MODE A portable unit in BASE SELECT MODE is indicated by flashing LED When a base is selected exit BASE SELECT MODE by briefly pressing M button voice confirmation BASE number GROUP 1 is given Notice All main units are delivered open for registration from factory and a DECT Com II system can be started directly out of the box by first starting a base portable unit as a base as described above and after that all portable units sequentially and continually as described above After the first turn off of the base unit the configuration of the system is fixed and future change of units has to be handled by your Authorised Peltor DECT Com II Dealer If your system is delivered pre registered in a certain configuration by your Authorised Peltor DECT Com II Dealer all future registration also has to be handled by your Authorised Peltor DECT Com II Dealer See also above 2 2 4 MAKE A BASE UNIT READY FOR PORTABLES TO BE REGISTERED 2 3 4 LOG ON A PORTABLE UNIT TO A BASE There are two versions of log on 1 At first
15. do por Eurofins Notified bodies Eurofins Storkower Str 38c 15526 Reichenwalde Germany V rnamo 2010 07 01 Place and date Sigvard Nilsson Development Manager Name and function of the signatory 3M Occupational Health amp Environmental Safety Division 3M Svenska AB Box 2341 SE 331 02 V rnamo Sweden Phone 46 0 370 65 65 65 Fax 46 0 370 65 65 99 Email peltorcommunications mmm com Please recycle Printed in Sweden Internet www 3M com Peltorcomms O 3M 2010 All rights reserved FP3689 Rev a
16. e actually used microphone gt In MICROPHONE MODE use the and buttons to set the used microphone type A voice message indicates your selected choice Last used setting is remembered between sessions 2 5 2 PTT Push To Talk There are three Push To Talk buttons PTT on a DECT Com II main unit PTT1 is always connected to conference group 1 while PTT2 and PTT3 are intended for groups 2 and 3 and or for possibly attached external equipment See 5 1 EXTERNAL EQUIPMENT below gt Press on a PTT button to enter as a member in a DECT Com conference see 2 4 LOG IN TO OR OUT OF A CONFERENCE The PTT function is also always available in VOX MODE Notice If PTT2 and or PTT3 are assigned for control of external communication equipment separate user s instructions may apply for any special application Contact your Authorised Peltor DECT Com Dealer for more information See 5 1 EXTERNAL EQUIPMENT 2 5 3 ALL CALL Emergency call etc It is possible to communicate in simplex mode with DECT Com II units in all groups on the base unit It is also possible to reach other DECT Com II conferences if their base units are synchronised and in range of each other The synchronisation should be done by starting the systems in range of each others If this function should always be accessible the bases have to constantly be in range for instance as fixed mounted bases If the bases have been out of range of each others it may take u
17. en respectively to confirm the actual mode Step backwards through the MODE steps by double press on the M button Voice messages MICROPHONE VOX VOLUME are given respectively to confirm the actual mode gt Use the and buttons to adjust the settings respectively Current settings are stored when the unit is switched off Notice A double press in VOLUME MODE and LISTEN ONLY MODE on a base unit will put the unit in REGISTRATION MODE see 2 2 4 MAKE A BASE UNIT READY FOR PORTABLES TO BE REGISTERED Double press in VOLUME MODE and LISTEN ONLY MODE on a portable unit will put the unit in BASE SELECTION MODE see 2 3 7 SELECT ANOTHER BASE FROM A PORTABLE UNIT 2 5 1 1 VOLUME sound pressure In VOLUME MODE the level of the incoming audio can be set in 5 steps gt Use the or button to set the sound level from the DECT Com unit voice message confirms the new setting each time you press a button 2 51 11 VOLUME BOOST higher sound pressure The volume levels on all active volume steps can be increased by 6 dB For instance this function can be used to compensate for additional attenuation from simultaneous use of ear plugs and headset Press the button for 10 seconds to activate VOLUME BOOST function voice confirmation EXTRA HIGH VOLUME is given when you have activated the function WARNING High sound pressure Last used setting remains between sessions gt Press the button for 1
18. for a LISTEN ONLY member to enter as an ACTIVE member in a conference group by pressing a PTT button If the conference already consists of the maximum number of members the first logged in ACTIVE member is pushed out to be a LISTEN ONLY member 2 4 2 LOGIN AS AN ACTIVE CONFERENCE MEMBER gt Double press on PTT to break in to one of the max three conferences A double tone is confirming that you are an active member in the selected conference gt Press once on the same PTT again to change to LISTEN ONLY MODE single tone is confirming that you are a listen only member in the conference 2 4 5 LOGIN AS A MEMBER IN ANOTHER CONFERENCE GROUP gt Press on another PTT button to become a member in another conference A tone is confirming that you are a member in the selected conference 2 4 4 AUTO TALK system for maximum 9 users using only group 1 can be programmed in a configuration where all the portables always should be in talk mode Automatic talk mode makes it possible to ensure that all the members in the small group always are speakers in the conference as soon as they are in range of the base unit For further information contact your Authorised Peltor DECT Com II Dealer 2 5 MAIN UNITS CONTROLS 2 51 MODE The MODE button M controls functions of the unit Step forward through the MODE steps in the menu by pressing briefly on the M button Voice messages VOX MICROPHONE VOLUME are giv
19. harger holder DC2064 or a power supply holder DC2068 It should also be used with a programming charger holder DC2065 but which is only available for Authorised Peltor DECT Com II Dealers 3 3 1 TECHNICAL DATA MAINS ADAPTER DC2061 Input 100 240 V 50 60 Hz 400 mA Output 9 0 V 1 0A 4 ANTENNAS A DECT COM II main unit normally works with one of two antennas one internal on the printed circuit board and one external antenna mounted in a connector on top of the unit 41 GENERAL ANTENNA The external antenna DC2041 which is delivered with all DECT Com II main units should normally be mounted on the main unit together with a plastic ring see 4 1 1 UNIT FUNCTION INDICATORS below 41 1 UNIT FUNCTION INDICATORS A package DC2048 with 3 differently coloured plastic rings is enclosed in the box of each DECT Com II main unit The rings are meant to seal around the antenna connector but also to indicate the function of the unit for instance a red ring for a base unit a green ring for a portable unit and a black ring for an other unit 4 2 OMNI DIRECTIONAL VEHICLE ANTENNA The omni directional antenna DC2046 with magnetic foot can replace the external antenna DC2041 for instance to improve communication with portable units outside of a vehicle if the base unit is placed inside Notice No other external antennas than DC2041 or DC2046 are allowed for use with the DECT Com II system 4 21 TECHNICAL DATA ANTENNA DC2046 Antenn
20. he mandatory mains adapter DC2061 which is included in the package at delivery of the power supply holder DC2068 When the energy in the battery is low voice messages announce that it is time to charge the batteries or when appropriate to change batteries The message BATTERY LOW indicates that the energy in the battery is low and you should charge or change battery as soon as possible The message BATTERY EMPTY indicates that the energy in the battery is very close to empty and the unit will automatically switch off 3 1 BATTERIES 3 1 1 RECHARGEABLE BATTERY PACK A Peltor rechargeable battery pack DC2033 is needed for the main units 3 1 1 1 CHARGING A BATTERY PACK A rechargeable NiMH battery pack DC2033 has to be charged in a main unit placed in a Peltor charger holder DC2064 It is sealed according to IP42 for use in dry areas Notice See also 3 1 3 TECHNICAL INFORMATION DC2033 below NOTICE No other power source than the Peltor DECT Com II mains adapter DC2061 included in the package at delivery may be used together with the power supply holder DC2064 It is equipped with exchangeable European UK and US type mains connectors for the input of 100 240 Volt AC 50 60 Hz 3 1 1 2 CHANGE OF INTERNAL BATTERY PACK aSwitch the unit off by pressing and holding the M button for approximately 2 seconds A voice confirmation POWER OFF is given and the LED is turned off Turn the clip aside Fig 1 and loose
21. is paired to the main unit it will replace the one which was first paired to the main unit Notice After approximately 100 000 pressings on the button a new unit needs to be paired to the main unit as the transmitter has a non replaceable battery 5 2 3 TECHNICAL INFORMATION ABOUT WIRELESS PTT Life time of the battery More than 100000 pressings on the button Range Typ 1 5 metres Frequency WLTX B 869 MHz Usage temperature 20 C to 60 C Storage temperature 55 C to 70 C Weight approximately 149 6 ACCESSORIES AND SPARE PARTS Please contact your Authorized Peltor DECT Com II Dealer DC2031 Battery lid for use with 3xAA standard batteries in main unit DC2032 Battery carrier for 6xAA auxiliary batteries excl batteries DC2033 Rechargeable NiMH accumulator 2100 mAh DC2035 Screw for battery lid DC2031 DC2036 Screw for battery carrier DC2032 DC2041 Antenna general 1 8 1 9 GHz for main unit DC2046 Antenna omni directional with magnetic foot DC2048 Antenna ring kit one of each colour red green and black DC2061 Mains adapter for charger holder etc common for EU UK and US DC2064 DECT Com II Charger holder 9 15 V DC IP42 incl mains adapter DC2061 DC2068 Power Supply holder 9 33 V DC IP67 incl mains adapter DC2061 DC2071 Attachment clip fully rotary for attaching the main units to clothes etc DC2072 Cable for Ground Mechanic DC2078 Connector sealing plug DC2 5001 Adapter cab
22. le for dynamic standard DC2 5005A Adapter cable for telephone 2 2 kOhm DC2 5010 Adapter cable for ICOM straight connector DC2 5030 Adapter cable for Motorola GP340 DC2 5063 Adapter cable for Motorola Mototrbo WLTX B Wireless PTT for remote control of the PTT function of an external radio connected to a DECT Com II main unit DC2811 DC2812 or DC2812 7 APPROVALS DECLARATION OF CONFORMITY See last pages in this user s manual APPROVALS Electrical safety EMC DECT radio SAR EN 60 950 2001 EN 301 489 01 2000 EN 301 489 06 2000 FCC part 15 Subpart D RSS 213 EN 301 406 V1 4 1 2001 EN63211 2008 FCC OET Bulletin 65 Supplement C Edition 01 01 17 8 WARRANTY 3M guarantee conformity with the contractual specifications of the quality and performance of the goods Full information about the Peltor warranty is available on request from your local 3M office Non conformity goods should be returned to your Authorized Peltor DECT Com II Dealer 9 PROGRAMMING DECT Com II UNITS Special software and a programming holder is available for customizing several functions in the DECT Com II system Contact your Authorized Peltor DECT Com II Dealer for further information For address to your nearest Authorized Peltor DECT Com II Dealer contact your 3M office July 2 2010 3M Declaration of Conformity 3M SVENSKA AB DECLARES THAT THE EQUIPMENT DESCRIBED HEREAFTER IS IN CONFORMITY WITH THE FOLLOWING EUR
23. le units can be logged on The LED can be switched off with use of special DECT Com II software 2 2 2 SWITCH A BASE PORTABLE UNIT OFF gt Switch a base unit off by pressing and holding the M button for approximately 2 seconds A voice confirmation POWER OFF is given the LED is unlit and the unit is turned off 2 2 3 ALTERNATIVE OPERATION MODES OF BASE PORTABLE UNITS By different start up sequences the base portable main units can be set up to work either as a base or as a portable unit 2 2 3 1 START THE UNIT AS A BASE UNIT Switch the unit on by pressing and holding the M and buttons simultaneously for approximately 2 seconds In a headset connected in the headset connector on the unit a voice confirmation BASE POWER ON is given confirming that the unit is started as a base unit After approximately 20 seconds the system is ready and a voice message GROUP 1 is given The LED on the unit is flashing slower showing that the base unit is ready for use and portable units can be logged on The LED can be switched off with use of special DECT Com II software A user with a headset connected in the headset connector on a base unit can also be participating in a DECT Com II conference similar to a portable unit Notice All units are always started in listen only mode in group 1 Last used alternative base or portable is remembered between sessions 2 2 3 2 START A BASE PORTABLE UNIT AS A PORTABLE UNIT Check that
24. n the screw with a suitable tool Fig 2 Caution When loosening the screw do not use your fingernail it can be broken Open the battery lid and replace the battery Fig 3 Push the battery pack down firmly to get the connecting plates in contact with the pins Hook the battery lid on to the bottom of the unit close it press down and tighten the screw again with the tool Caution When tightening the screw do not use your fingernail it can be broken 3 1 1 3 TECHNICAL INFORMATION DC2033 Chemical structure NiMH Nominal Voltage 3 6 V Nominal Capacity 2100 mAh Usage temperature 25 C to 55 C Storage temperature 55 C to 70 C Notice Remove the battery pack from the main unit if it should not be used in a month s time or longer Charging temperature 5 C to 45 C Charging time Up to 12 hours at 20 C Notice It is normal that the battery may become warm during charging or use At first time use or after long time storage it may take three to five full charging cycles to reach full battery capacity Battery life time Approximately 250 charge cycles Notice The battery capacity will decrease after many recharge cycles or as the battery pack ages Weight Approximately 100 g 3 1 2 CHARGER HOLDER DC2064 The battery pack DC2033 must be charged in a main unit DC2811 DC2812 or DC2815 Charging is indicated with a red LED on the charger When the LED turns green the charging is finished An initial fl
25. ove and after that all portable units sequentially and continually as described above After the first turn off of the base unit the configuration of the system is fixed and future change of units has to be handled according to description above If your system is delivered pre registered in a certain configuration by your Authorised Peltor DECT Com II Dealer all future registration has to be handled by your Authorised Peltor DECT Com II Dealer 2 3 PORTABLE UNIT 2 3 1 SWITCH A PORTABLE UNIT ON Switch the portable unit on by pressing the M button In a headset connected in the headset connector on the unit a voice confirmation POWER ON is given and the LED on the unit is flashing green showing that the unit is logging on to the base When the unit is ready for use a voice message BASE 1 GROUP 1 is given and the LED is steady green Notice All portable units normally start in listen only mode in group 1 At first start up a voice message SEARCHING is given When a base is found a voice message BASE number GROUP 1 is given When restarting a portable unit which is programmed to be able to work with more than one base it will try to log on to the last used base 2 3 2 SWITCH A PORTABLE UNIT OFF Switch the portable unit off by pressing and holding the M button for approximately 2 seconds voice confirmation POWER OFF is given and the LED is turned off If the unit is still searching for a
26. p to 20 minutes to get them synchronised again gt Press and hold UP and DOWN buttons simultaneously to transmit a short message A double tone is confirming that the ALL CALL is activated The transmission period is limited normally to max 30 seconds 2 5 4 LOCKED BUTTONS To avoid unwanted changes in the settings of functions it is possible to lock all buttons so that only the ON OFF function is active This can preferably be combined with the automatic talk mode function See also 2 4 4 AUTO TALK above Notice Many of the functions and settings in DECT Com II can be adjusted according to the user s demands For further information contact your Authorised Peltor DECT Com II Dealer 2 5 6 OUT OF RANGE Peltor DECT Com Il is a short range communication system See 2 6 TECHNICAL INFORMATION MAIN UNITS below If the portable unit is close to the actual maximum working range from the base unit a voice message SIGNAL LOW is given in the connected headset When the portable unit is out of range from the base unit a voice messages SIGNAL LOW OUT OF RANGE OUT OF RANGE is given in the connected headset After another 20 seconds the may try to find another base and a voice message SEARCHING is given When the portable unit is in range again or another base is found a voice message BASE number is given in the connected headset If automatic talk mode function is activated a portable unit after being out of
27. plies some extra delivery time 5 2 1 DESCRIPTION OF WIRELESS PTT The wireless PTT unit is a push button combined with a radio transmitter for sending impulses to a corresponding receiver which may have to be mounted in a main unit after order press on the button on the wireless PTT transmitter unit is equal to a press on a PTT button on a main unit in which a corresponding receiver is placed and which is paired to the transmitter For example a press on a wireless PTT transmitter will be recognised by the main unit as a press on the PTT button with which it is paired Two wireless PTT transmitters can be linked to one receiver unit The use of this wireless PTT transmitter is license free in the European Community The user is responsible for any license in other countries Consult your Authorized Peltor DECT Com II Dealer 5 2 2 PAIRING OF WIRELESS PTT The wireless PTT transmitter should be paired with the corresponding receiver which is connected in parallel with one of the PTT buttons on the main unit For paring a transmitter with a receiver in a main unit short circuit the two pads to the right on the backside of the main unit and at the same time press the button on wireless PTT transmitter 691 OrBdvxd ar 910 84 vyogs d a If another wireless PTT transmitter is paired to the same receiver unit it will have the same function as the first wireless PTT transmitter However if a third wireless PTT transmitter
28. s armonizada s n m EN 301 406 EN 60950 EN 62311 Este equipo es id ntico al CEM sujeto del certificado de conformidad CE nimero G0M21005 3251 T 62 G0M21005 3251 E 12 emitido por Eurofins EMC Radio equipment and telecommunicatons EMC EN The EMC Directive sets requirements for electromagnetic emission and immunity limits for electric electronic products liable to generate electromagnetic disturbance or the performance of which are liable to be affected by such disturbance This equipment is in conformity with the provisions of Council Directive 1999 5 EC RTTE 19 20 July 2 2010 3M and where such is the case with the national standard transposing harmonised standard s No EN 301 489 1 EN 301 489 6 This equipment is identical to the EMC which is subject of EC certificate of conformity No G0M21005 3251 E 12 issued by Eurofins ES La Directiva CEM establece los requisitos de emisi n electromagn tica y l mites de in munidad para productos el ctricos electr nicos susceptibles de generar perturbaciones o cuyo rendimiento pueda verse afectado por dichas perturbaciones Este equipo est fabricado de conformidad con las disposiciones de la Directiva del Consejo 1999 5 EC RTTE y cuando corresponde con la norma nacional correspondiente a la s norma s armonizada s n m EN 301 489 1 EN 301 489 6 Este equipo es id ntico al CEM sujeto del certificado de conformidad CE n mero G0M21005 3251 E 12 emiti
29. the actual base unit is switched on and ready gt Switch the unit on by pressing and holding the M and buttons simultaneously for approximately 2 seconds In a headset connected in the headset connector on the unit a voice confirmation POWER ON is given confirming that the unit is started as a portable unit After approximately 10 seconds the unit is ready and a voice message BASE GROUP 1 is given The LED on the unit is lit showing that the unit is ready for use as a portable unit and is logged on to base No The LED can be switched off with use of special DECT Com II software Notice All units are always started in listen only mode in group 1 Last used alternative base or portable is remembered between sessions 2 2 4 MAKE A BASE UNIT READY FOR PORTABLES TO BE REGISTERED Each portable unit should be registered to a base unit to be part of a DECT Com II conference gt With the base unit in LISTEN ONLY and VOLUME MODE double press on the M button to enter REGISTRATION MODE A base unit in REGISTRATION MODE is indicated by a voice confirmation SUBSCRIPTION ON and the LED flashing slowly gt When all portable units are registered to the base unit exit REGISTRATION MODE by double pressing M button Notice All main units are delivered open for registration from factory and a DECT Com II system can be started directly out of the box by first starting a base portable unit as a base as described ab
30. working range may be shorter due to actual conditions Read all of these instructions carefully before use and save for future reference Never modify or alter any product 3M does not accept liability of any kind be it direct or consequential including but not limited to loss of profits business and or goodwill arising from reliance upon any information herein provided by 3M The user is responsible for determining the suitability of the products for their intended use Nothing in this statement will be deemed to exclude or restrict 3M s liability for death or personal injury arising from its negligence 2 MAIN UNITS A Peltor DECT Com II portable unit DC2811 is a personal radio transmitter receiver to which a headset should be connected Any Peltor headset with J11 connector wired according to Peltor standard can be connected to a Peltor DECT Com II portable unit A Peltor DECT Com II base portable unit DC2812 is a central radio transmitter receiver which is needed to communicate all information from and to all portable units in a DECT Com Il system A Peltor DECT Com II extension base portable unit DC2815 is a central radio transmitter receiver equal to a base portable unit but to which external equipment can be connected to extend the DECT Com Il system Any Peltor headset with J11 connector wired according to Peltor standard can also be connected to a Peltor DECT Com II base portable unit 2 1 SWITCH A MAIN U
Download Pdf Manuals
Related Search
Related Contents
(M)SDS - 純正化学株式会社 製品検索・MSDS検索 Steren 550-030 User's Manual Sony SRS-PC45 User's Manual Lecture 1: Introduction and Background - LCG-UFRJ „Contessa 1002“ - Bartscher GmbH Évaluer l`apprentissage par ordinateur : Tâches et rétroactions Roncato 2 Trolley Set Adronic Components GmbH PDFカタログ Copyright © All rights reserved.