1. Vac hose cut to length using the hose cutter Both the hose and the hose cutter are available in the miVac Connection Kit Part Number MCK 00000 Y00 or hoses separately part numbers vacuum hose 04 4783 exhaust hose 04 5016 If you do not have the SpeedTrap just connect the hose between the concentrator and the pump The arrows on the diagram indicate the direction of vapour flow Connect the interconnecting cable A supplied in Connection Kit between the connector on the Concentrator and the connector on the Pump Do not use the Mains Power Cable supplied with the pump this is supplied for standalone use of the pump only Connect Mains Power Cables B and C supplied to the connector on the SpeedTrap and your Mains Supply and to the connector on the Concentrator and your Mains Supply NOTE The interconnecting cable is only to be used between the Concentrator and the Pump SPEEDTRAP Collection jar fitting and removing To fit the jar position so that the handle is to the front lift the jar and rotate to the right a quarter turn until resistance is felt The collection jar is removed by rotating the jar to the left a quarter turn a LEI ELi Loi The blue LED on the front of the SpeedTrap indicates the current condition Genevac Limited The Sovereign Centre Farthing Road Ipswich IP1 5AP UK Tel 44 0 1473 240000 fax 44 0 1473 461176 Genevac Inc SP Industries 815 State Route 208 Gardiner NY 12525 USA Te
2. THE MIVAC SERIES QUICK START GUIDE Vac pe _ 1 Refer to User Manual for Safety and Maintenance Notes 2 Connect mains power lead see diagram on reverse 3 Open Lid For Quattro Concentrator ensure that the latch engages 4 Fit rotor by carefully sliding it on to shaft 5 Load the rotor with your samples ensure that they are evenly balanced 6 Close Lid For Quattro Concentrator lift lid to disengage latch 7 Set Chamber Temperature see below if no temperature is selected the unit will run at the current chamber temperature 8 Set Run Type see below if no type is set the unit will use the current settings 9 Set Total Run Time see below if no time is set the unit will use the current settings 10 Set Heat Time see below if no time is set the unit will use the current settings 11 Press MANUAL or AUTO button to start the run 12 If the MANUAL button was pressed the STOP button will need to be pressed to stop the run 13 If the AUTO button was pressed the run will stop after the TOTAL time has passed 14 The end of run is confirmed by the system emitting 4 long beeps and unlocking the lid NOTE The rotor may continue to spin slowly after the run has ended WHEN REMOVING YOUR SAMPLES CARE SHOULD BE TAKEN AS THE CHAMBER AND SAMPLE HOLDERS WILL BE AT THE SAME TEMPERATURE THAT WAS SET FOR THE RUN OPTIMISING THE RUN SETTINGS To set and adjust the required parame
3. l 1 845 267 2212 Fax 1 845 267 2212 Email salesinfo genevac co uk Web Site http www miVac co uk Tech Support service genevac co uk
4. ters use the selector knob located on the right of the control panel to move to the desired position the display changes with appearing at each location in turn this means that this is the value that will be adjusted To adjust the value press the knob to select it the will flash then turn the knob to increase or decrease the value Once the correct value is attained press the knob to accept it Repeat the procedure for all parameters See example below NOTE The selected value will be accepted automatically after 30 seconds if you do not press the knob Once you press the knob to accept the new value the display reverts back to displaying the current chamber temperature We have used 24 C as the current temperature for the example Example Setting Chamber Temperature re 2 rm Tag r mec rm ow arc mn ow WU tu uu ru rut Select Parameter Adjust Value After Accepting Value NOTE For error messages and troubleshooting refer to User Manual a r 04 5058 Issue 1 4 Genevac technology is protected by patents and patent applications in the USA and worldwide October 2008 SETTING UP NOTE The system is to be positioned so that there is a 50mm air gap between each unit and the next object wall fume hood etc EXTRACTION SYSTEM i CONCENTRATOR PUMP SPEEDTRAP NOTE Ensure that the Catchpot is fitted to the lower row of vent holes on the Pump Follow the diagram above to connect the units together using 2
Download Pdf Manuals
Related Search
Related Contents
GE WWA8324B User's Manual SOFTWARE REQUIREMENT SPECIFICATION FOR MONEY Programmable Multiband Amplifier / User Manual Gigabyte GA-X58A-UD7 Fluke MP3 User's Manual Wentronic E27 Classic PAR20 Sistemas de medición láser 2331.2kB KitchenAid Counter Depth Side-by-Side Refrigerator Refrigerator User Manual 平成27年9月ー5日 佐 倉 Política para el Reclamo de Garantías Copyright © All rights reserved.
Failed to retrieve file