Home

UVD-XP4DNR(-P) Camera User Manual

image

Contents

1. Product description The UVD XP4DNR P rugged dome color video cameras is a 24 VAC 12 VDC model The cameras are equipped with a digital signal processor DSP for processing the video signal Features Camera features include e Next generation XPosure technology e Improved low light performance and color balance e 540 TVL lines color e Dynamic range 95 dB typical 120 dB maximum e Preset modes optimized for various environments e On screen display interface User guidelines Use the following guidelines e Program as many camera settings as possible before mounting the camera Take appropriate safety precautions while completing programming after installation e Always use a 12 VDC or 24 VAC UL listed Class 2 power supply to power the camera e Do not use the camera outside the temperature range specifications 57 to 122 F 50 to 50 C e ifthe light source where the camera is installed experiences rapid wide variations in lighting the camera may not operate as intended WARNING To reduce the risk of fire or electronic shock do not expose the camera to rain or moisture and do not remove the cover or back Components Figure 1 shows the main components of the rugged dome unit Figure 1 Rugged dom2e unit Bubble Lens body OSD control pad Camera body Video monitor output Figure 3 shows the monitor output components Figure 2 Monitor output cable A Monitor output BNC B
2. gt MOTION THR DIG Z00M DIG PAN DIG TILT PREV SAVE CANCEL Motion detection menu The Motion detection menu Figure 11 above provides the following options e Motion Threshold Set the level of sensitivity of the motion detection e Digital zoom Determine how far in the camera zooms upon alarm By default the camera zooms to the center of the screen e Digital pan Adjust where the camera zooms upon alarm Move the slider to the left to pan left and to the right to pan right e Digital tilt Adjust where the camera zooms upon alarm Move the slider to the left to tilt down and to the right to tilt up Setup motion zone The camera will monitor for motion in the area defined in the boxes defined in this submenu Figure 12 below When motion is detected in this area the camera issues an alarm and zooms in Figure 12 Motion zone setup MOTION ZONE SETUP gt SET ACTIVE ZONES lt 1 ZONE gt ADJUST ZONE 1 ADJUST ZONE 2 ADJUST ZONE 3 ADJUST ZONE 4 PREV SAVE CANCEL Figure 13 Alarm zone setup To set up the alarm zone do the following 1 Choose one of the options Adjust Zone 1 2 3 4 from the Setup Motion Zone menu Figure 12 The selected zone will have a thick border and be highlighted in white Press the arrow keys to change the selected zone Figure 13 2 Press Enter The selected zone becomes green Press the arrow keys to increase the zone area 3 Pres
3. interlogix A UTC Fire amp Security Company UVD XP4DNR P Camera User Manual Content Preface 1 Safety terms 1 Product description 1 Features 1 User guidelines 2 Components 2 OSD control pad 2 Installation 2 Cable connection 2 Camera installation 3 Angle adjustment 3 Focus adjustment 3 Connect the monitor 3 Programming 3 Navigation 3 Main menu 3 Presets menu 4 Setup menu 4 Viewing menu 6 Exposure menu 6 White balance menu 6 Save restore menu 7 Contacting support 7 Regulatory information 7 Menu Map 8 Preface This is the UVD XP4DNR P Camera This document includes an overview of the product and detailed instructions explaining e how to connect the camera and e how to program the camera e how to adjust the camera angle and focus To use this document effectively you should have the following minimum qualifications e abasic knowledge of CCTV systems and components and P N 1079204A EN REV R1 0 ISS 20DEC11 e abasic knowledge of electrical wiring and low voltage electrical connections Note A qualified service person complying with all applicable codes should perform all required hardware installation Safety terms These terms may appear in this manual CAUTION Cautions identify conditions or practices that may result in damage to the equipment or other property WARNING Warnings identify conditions or practices that could result in equipment damage or serious personal injury
4. ID CAMERA 1 ID POSITION UP LEFT SAVE CANCEL PREV Sync menu The SYNC option in Setup menu Figure 8 on page 19 provides the following INT or LL LINE LOCK options INT Internal sync Used with DC power input to reduce the phase roll of fluorescent lights LL Line lock Used to sync video for AC power input so that the sync matches the frequency of the power input to eliminate the roll caused by fluorescent lights Figure 10 UVD XP4DNR P Camera User Manual Figure 9 Line lock menu LINELOCK Litittt tt 0 519 624 V PHASE SAVE CANCEL Motion detection setup A motion detection alarm refers to an alarm triggered when the camera detects a motion The Motion detection setup display Figure 10 provides the following options e Motion options ci dessous e Setup motion zone ci dessous Figure 10 Motion detection zone setup MOTION DETECTION SETUP gt MOTION OFF SETUP MOTION ZONE PREV SAVE CANCEL Motion options Off Motion detection is disabled Motion det Motion detection is enabled with default motion settings Enter the submenu Figure 11 to change the settings see Motion detection menu below When motion is detected the word Alarm is displayed on the top left of the screen and the image is zoomed tilted and panned to the area setup in Setup alarm zone UVD XP4DNR P Camera User Manual Figure 11 Motion detection menu MOTION DETECTION MENU
5. Monitor output RCA Plug the monitor output RCA into the video monitor output and connect the monitor output BNC to the TV monitor OSD control pad The on screen display OSD control pad Figure 3 is a five direction joystick that provides the ability to manually control the camera functions Table 1 below lists the OSD control pad functions and describes their use Figure 3 OSD control pad OSD control pad Table 1 OSD control pad controls Pad directions Description Up Moves the cursor upward to select an item Left Moves the cursor left to select or adjust the parameters of the selected item Right Moves the cursor to the right to select or adjust the parameters of the selected item Down Moves the cursor downward to select an item Enter Press the center of the control pad to display the Setup menu If the selected item has its own menu press the control pad to enter a submenu Press the control pad for 2 seconds to save all settings and exit the Setup menu Installation This chapter provides information on how to install the camera and adjust camera angle and focus To install the camera you will need to prepare the mounting surface make cable connections and mount the camera Cable connection To make cable connections do the following 1 Connect a coaxial cable from the camera s BNC connector to a CCTV monitor or video recording device UVD XP4DNR P Camera User Manual 2 Connect a 12 VD
6. conditions out of the box This mode supports 14 bits of dynamic range and gives priority to rendering the highlights in the scene Indoor This preset supports 16 bits of dynamic range and gives priority to rendering the shadows in the scene Outdoor This preset offers the highest dynamic range of 17 bits and gives priority to rendering the highlights in the scene Flickerless This mode uses line lock to eliminate phase roll under fluorescent lights It must be used with a 24 VAC power supply NTSC50Hz This mode uses a DC iris lens to reduce phase roll under fluorescent lights This mode will not function correctly with a manual iris lens Setup menu The Setup menu Figure 7 provides the following options e Camera ID setup menu below e Sync menu below e Motion detection setup on page 5 e WODR setup safe area center spot lower 1 8 or full screen Figure 7 Setup menu SETUP gt ID SETUP SYNC INT MOTION DETECTION WDR SETUP PREVIOUS PAGE SAFE AREA Camera ID setup menu The Camera ID setup menu Figure 8 provides the following options e ID display off or on e Camera ID Press Right to move the cursor to edit the camera ID Press Up or Down to select the ID When complete press Up or Down to leave the editing field e ID position up left up center up right down left or down left Figure 8 Camera ID setup CAMERA ID SETUP gt ID DISPLAY OFF CAMERA
7. 004 108 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info Contact information For contact information see www interlogix com or www utcfssecurityproducts eu Menu Map Main Presets ID Display Comeran ID Position Setup r Internal Sync Syne Motion Threshid Setup Mot Zone Digital Zoom Digital Pan WOR Setup eigen Center Spot Motion Detect Lower 1 3 Full Screen Flip Resolution Exposure G O AE Preferences Range Control Shutter Limit Frame RPT B W Control White Balance Mode gt PTL Save Restore Save User Set Reset User Set Reset Fact Set Reset Camera Exit 8 UVD XP4DNR P Camera User Manual
8. C or 24 VAC power supply to the power input The label on the camera gives the following information Red cable Power in Black cable Power in White cable Video out Black cable Video ground Note For AC24V or DC12V Black or Red may be used for ground Camera installation To mount the camera attach the camera to the mounting surface using the appropriate fasteners Angle adjustment To adjust the horizontal angle of the platform up to 180 degrees turn the platform Figure 4 To adjust the horizontal angle of the rotor up to 350 degrees turn the rotor on the platform Figure 4 To adjust the vertical angle of the platform up to 90 degrees turn the platform Figure 4 Figure 4 Camera adjustment Platform horizontal adjustment Platform vertical adjustment Rotor horizontal adjustment Focus adjustment To adjust the camera zoom and focus see Figure 5 and do the following 1 Loosen the zoom ring thumbscrew Turn the zoom ring to set the desired zoom Tighten the zoom ring thumbscrew Loosen the focus ring thumbscrew Turn the focus ring to set the desired focus YO e 2 P Tighten the focus ring thumbscrew UVD XP4DNR P Camera User Manual Figure 5 Zoom and focus adjustment Zoom ring thumbscrew for Focus ring thumbscrew for VA2 and focus ring for VA9 VA2 and zooming ring for VAY lens lens Connect the monitor Program the cameras by attaching a standard video monitor to the sys
9. mera User Manual Save restore menu The Save restore menu Figure 17 provides the following options e Save user settings Saves all current changes e Restore user settings Discards all current changes e Restore factory settings Resets all settings to factory levels e Reset camera Resets the camera Figure 17 Save restore menu SAVE RESTORE SAVE USER SETTINGS RESTORE USER SETTINGS RESTORE FACTORY SETTINGS RESET CAMERA PREVIOUS PAGE Contacting support For help installing operating maintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions contact us during business hours Monday through Friday excluding holidays For contact information see www interlogix com Table 2 Technical Support Europe Middle East and Africa W Select Contact Us at www utcfssecurityproducts eu North America T 1 855 286 8889 E techsupport interlogix com Australia E techsupport interlogix au UVD XP4DNR P Camera User Manual Regulatory information Copyright Trademarks and patents Manufacturer FCC compliance ACMA compliance Canada Certification European Union directives 2011 UTC Fire amp Security All rights reserved Interlogix UltraView brand and logo are trademarks of UTC Fire amp Security Other trade names used in this document may be trademarks or registered trademarks of the manufacture
10. rs or vendors of the respective products UTC Fire amp Security Americas Corporation Inc 2955 Red Hill Avenue Costa Mesa CA 92626 5923 USA Authorized EU manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert The Netherlands Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme ala norme NMB 0330 du Canada E na131 12004 108 EC EMC directive Hereby UTC Fire amp Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2
11. s Enter The selected zone becomes red Press the arrow keys to shrink the zone area 4 Press Enter for a few moments to leave the Alarm Zone Setup menu and return to Motion Zone Setup menu Viewing menu The Viewing menu Figure 14 provides the following options e Flip OFF HORIZ VERT BOTH flip off or on e Resolution HIGH NORMAL High or normal The High option over sharpens the image for higher resolution Turn horizontal Figure 14 Viewing menu VIEWING gt FLIP RESOLUTION PREV SAVE CANCEL Exposure menu The Exposure menu Figure 15 provides the following options e AGC medium high custom or low The camera automatically adjusts the image quality in low light conditions e AE preferences highlights or shadows e Range control low normal high or custom e Shutter limit x2 x4 x8 x16 x32 or off A fast shutter speed captures clear images of fast action e Frame RPT OFF ON B W Control OFF ON Figure 15 Exposure menu EXPOSURE gt AGC MEDIUM AE PREFs HIGHLIGHTS RANGE CTRL NORMAL SHUTTER LIMIT x2 FRAMERPT OFF B W CONTROL ON PREVIOUS PAGE White balance menu The White balance menu Figure 16 provides the following options e Mode ATW or PTL ATW mode is automatic trace white balance In PTL mode you can set a specific white balance Figure 16 White balance menu WHITE BALANCE gt MODE ATW PREV SAVE CANCEL UVD XP4DNR P Ca
12. tem To connect the monitor do the following 1 Plug the monitor output cable Figure 2 to the video monitor output connector Figure 1 2 Connect the BNC cable to the video monitor 3 Press Enter see OSD control pad on page 9 to display the Setup menu Programming This chapter describes how to navigate the programming menus to adjust the camera settings Navigation To access and navigate the menus press and hold the center of the OSD control pad Figure 3 Press Up or Down on the control pad to move between items and press Enter center of the control pad to select the item Press Right or Left on the control pad to select the different options available for the item You can return to the previous menu from any of the menus except the Main menu by selecting the Previous page option Main menu The Main menu Figure 6 provides the following options e Presets menu en page 4 e Setup menu en page 4 e Viewing menu en page 6 e Exposure menu en page 6 e White balance menu en page 6 e Save restore menu on page 7 e Exit menu exits the menu system There is a menu map provided on the back page of the manual Figure 6 Main menu MAIN MENU gt PRESETS SETUP VIEWING EXPOSURE WHITE BALANCE SAVE RESTORE EXIT MENU NORMAL Presets menu The Presets menu options include Normal This is the camera default preset for general lighting

Download Pdf Manuals