        40A solar controller - Eco
         Contents
1.  the accumulated discharging power for loads  Total  ampere hour   long press the button ggg more than 5seconds  the value  will back to zero        4 Set the parameters  At the main interface press for long   gt 5 seconds  and the number starts flickering  to enter into parameter  Setting interface  Press    for short   lt 1 second  to reset the parameter  and press  amp   7   to adjust this    parameter  a     PV OFF cis d pe bt Q   i 7 V   _ High Voltage a     Low voltage  Disconnection  HVD  Reconnection  LVR     cou    Figure 2 g   2   LOAD ON cy i  Load   Low voltage  Working Mode ww e aA  7 Disconnection  LVD        4 1 Set the High Voltage Disconnection   As shown on the right  shows the values for the HVD voltage When   the battery voltageis reach to HVD voltage  the controller will anG     cut off the charging circuit to prevent over charging battery  yai i  Battery voltage drops under the value the charging circuit will   be re connected In this interface  numbers start flashing  you can   use the key        to adjust the parameter  After long press the key E   gt   5seconds   to exit parameters etting interface  the controller will save the settings     a   gt        4 2 Set the Low Voltage Reconnection  As shown on the right  shows the values for the LVR voltage  Under the LVR  protection in the controller  when the battery voltage is restored to the higher voltage       than LVR voltage  the controller will re connect the load circuit  In this interface   number
2. EC  WORTHY    www eco worthy com Email  info  eco worthy com    Intelligent Solar Charge Controller    User s Manual    CM50242      ie   Ww        Please read this manual carefully before you use this product    Catalogue    1  Product  ntroduction                     cccccccccsssssssssssseees 2  2  Installationn               ccccccccccccrtess Maree MocMecccssscsssccee 3  De Operaatio MN iceieccscecceiceceseececlk ca  West eatea a is 4  4  Common Fault and Handling                   sssssssssees 9  5  Quality ASSUBATIGR     csscccrsscsssnccccsscesoscvcsccsescsoneses 10    6 Technical DRM 2           cccescescscescesccccscessccccccsccscsccscesces 11    1  Product Introduction    CM series controller is a kind of intelligent  multi purpose solar charge and  discharge controller  The family use the fixed LCD display  with a very friendly  interface  various control parameters can be flexibly set  fully meet you   re your  various application requirements    CM series controller has following features     Image of LCD graphic symbol   Simple button operation   Automatic Identification System Voltage level  Intelligent PWM charge mode   Automatic Temperature Compensation  Adjustable charge discharge control parameters  Settable Operating mode of Load   Overload  Short Circuit Protection   Remote monitoring and control function  custom   Battery reverse discharge protection   Battery Low Voltage Disconnection  LVD   Battery reverse connection protection  Accumulated function of c
3. harge and discharge Ampere hours           2  Installation        Remote  monitoring  and control  port    Install      1  Ready tools and cables  Encourage you to matching  the right cables  Ensure that the current density lt 4mm     that is conductive to reducing the line voltage drop   Recommended  50A with 16mm cable    Check weather the installation sites compliance with  the relevant safety requirements  Please avoid the  damp  dusty  there is a place flammable  explosive and  corrosive gases use the controller to install          Temperature  Sensor Port        2  Install the controller into a fixed vertical plane  See  section 5 of the pore size and pore spacing  In order  to ensure a good thermal control conditions  please   set aside each 10cm below the controller space      8  As shown on the right  connect the  1  Load  Battery    2  Battery and  3  Solar Panel to the controller according to the order of  1   2   3   Pay attention   to the load  battery  solar panel and controller of same polarity     4  Put into the external temperature sensor on the left of the controller  probe port   The temperature   sensor should be similar space with battery   Otherwise  the controller will control the parameters of   all wrong temperature compensation         If you have remote monitoring and control function  please insert one end of the included   communication wire on the right of the controller  communication port   the other end to connect to   The host computer    De
4. in action many timers do     10    5  Quality Assurance  1  Quality assurance should be carried out according to the following rules     The product is guaranteed of replacement  returning and repairing within 7 days after Sale     The product is guaranteed of replacement and repairing within 1 month after sale     The product is guaranteed of repairing within 12 months after sale   2  If it is not possible to identify the using date of the controller  we would refer to the ex work date  and  prescribe 18 months as the warranty period  We need to charge beyond the warranty period  The controller can be    repaired for life no matter when and where you use it     3  If the controller is damaged by the following causes  we need to charge even if itis In the guarantee period     Do not operate according to the user s manual    Use the controller under the condition which is beyond the using standard and technical requirements    Repair by yourself or reform by yourself    The inappropriate environmental condition which can cause the breakdown and aging of the apparatus     Improper carrying or storage     Regarding to the service of replacement  returning and repairing  you need to retreat the product to our  company  and we decide whether to replace or repair after we make clear who should be responsible     4  We will not note if there is any change of this product     11         a     ent    Rated voltage  Maximum voltage  of solar panel  Float voltage  Low Voltage  Disconnec
5. molition  To prevent accidents  please order the demolition of solar panels  battery and load disconnect with    4    controller   Note  Battery polarity will not damage the controller  but you will have a load equipment security risks     3  Operation    1 Description of LCD graphic symbol    A   Stop powered Status for Loads a o Stop the battery charging  r   Power to the load status   the load circuit without current    e  gt    Bulk charging the battery  J Teu Sus h an     The load circuit with current D   Float charging the battery  P   Load SS   The system is working correctly     i   Solar Panel on   The system is not working properly  C   Load sensor control Camm  Battery charge capacity instruction    Load timer control Ea   Battery    2 Description of Button Function   BPs Interface loop switch button  use the button to cycle between pages in each switch cycle sequence shown in   figure 1    Adjustment of parameters plus buttons  In addition  at the state in the parameter view  long press the button  more than 5 seconds  all parameter to restore factory setting     Ja    Adjustment of parameters minus button  In addition  in the main interface  click this button to switch the  load     eo  w CUU 4       cou   5  g K j g       oy   wv    Solar Panel       Battery Voltage Battery   main interface  temperature charge current  sola nag   UU a     Q       Accumulated Accumulated Load  Discharging power Ah  charging power Ah  discharge current Ah     Figure 1  3 View the 
6. on and Treatment  Screen display as shown in the figure that the battery drops below the LVD  protection voltage  The controller has entered the LCD protection state  load circuit  has been disconnected  Use the solar panels recharge the battery or charger when  the battery voltage reaches LVR voltage  the controller will resume on the load  power supply  into the normal working state     Over load Protection and Treatment   Screen display  see the figure  and flashing expressed load loop circuit current  sustained 60seconds than 1 5times rated current  the controller has entered into  overload protection state  After reduce the load  press the button We  to restore  power to the load     Short Circuit Protection and Treatment   Screen display  see the figure on the right  and flashing expressed there is short  circuit on the load loop circuit  The controller has enter into Short Circuit Protection  state Check the load if there is damage or not  if there is cable short circuit or not   after trouble shooting short press V     the button for restoration        Solar Panel Fault and Treatment   Symbol flashing represent the controller was not detected solar panels within 24hours  Check if  there is a connection from solar panel  check if there is an open circuit between solar panels with  controller     Load Shock Fault  Open load ifthe   flashing  that indicate the load impulse current is more than twice rated current of  the controller  The controller is restarting the load 
7. parameters  The controller will default entry    battery voltage    interface after correct power on  This is the main    interface   Use the button    could in turn visit the following parameters interface    3 1 Battery Voltage of View  As shown on the right  displays the value for current battery voltage     This interface  based interface  displays charge status  discharge  status  battery capacity and battery voltage        3 2 The load on off control  View the interface in the battery voltage could be        used key W  On  off the load  In other interface       gt   F  a    es E    cou    g    The key there is no such feature     3 3 Environment Temperature of Vie ape  As shown on the right  displays the ambient temperature of the   F como  controller  the value used for temperature compensation on LVD function  a oe    The sensor must be plug in before using the controller     3 4 Solar Panel charging current of View  As shown on the right  display the value of charging current from solar  panel     3 5 Load discharging current of View  As shown on the right  display the value of discharging current for  Loads     3 6 View the Accumulated charging power  Ah  by solar panel and back  to zero  As shown on the right  display the accumulated charging power from solar  sanel  Total ampere hour   long press the button more than 5seconds   The value will back to zero     3 7 View the Accumulated discharging power  Ah  by Load and Back to zero   As shown on the right  display
8. s start flashing  You can use the key V       the parameter  After long press  the keyi   gt Sseconds  to exit parameter setting Interface  The controller will save the settings     4 3 View and set the Low Voltage Disconnection Protection  As shown on the right  shows the values for the LVD protection voltage   When the battery voltage is lower than protection voltage  the  controller will disconnect the load circuit to prevent battery  over discharge  In this interface  numbers start flashing  that has  entered the LVD setup interface  you can use the key VO  Ato adjust  the parameter  After long press the key   gt Sseconds  to exit parameter setting  interface  the controller will save the settings       4 4 View and set Load Working Mode  As shown on the right is Load working mode interface  different values  represent different load working patterns     24h said Normal Mode  in case of no fault state of the load is always in power  LOAD ON ae s  1h 23h said Light Control with Time Control Mode  Load power after dark     and close the load according to the timer setting  pe       Oh said Light Control Mode  Load power after dark  turn off the load after drawn   In this interface  numbers start flashing  that has entered the Load Working Mode  setup interface  you can use the key W    A to adjust the parameter  After long  press the key   gt Sseconds  to exit parameter setting interface  the   controller will save the settings     4  Common Fault and Handling  LVD Protecti
9. tion  Low Voltage  Reconnection  No load loss  Loop voltage  drop    Charging  mode    Temperature  compensation    CM5024Z  40A 50A  12V 24V   lt SOV  13 7V 27 4V  10 7V 21 4V    12 6V 25 2V   lt 30mA   lt 200mV    PWM Mode     4mV Cell   C    cmsoas  PEL   omsozaz   cmsos  40A  50A  gt 3  AWG   lt 25mm      cable area  temperature   lt i00V 30 70   temperature  54 8V  lt 90   No Condensation  equirement  42 8V 130mmx188mmx62mm    50 4V 98 mmx178 mm   O5  spacing    Model suffix   Z    represent automatic identify system voltage level           T    represent controller with remote monitoring     12    
    