Home

UHH2 - Dwyer Instruments, Inc.

image

Contents

1. Bulletin TE UHH2 The Model UHH2 Universal Handheld Test Instrument provides the functionality and versatility of the Mobile Meter Software App on a rugged IP68 Android based handheld Wireless anemometer hygrometer and pressure probes communicate to the handheld using Bluetooth SIG Inc wireless technology and can all be displayed simultaneously Each UHH2 includes a UHH2 handheld base unit UHH BTG wireless mobile gateway two USB charging cables charging block mini screwdriver user manual and headphones FEATURES BENEFITS e Rugged weatherproof housing withstands 1 5 meter drop test e Wireless measurement of pressure air velocity air flow temperature and humidity e Share logged data directly from handheld over Wi Fi GSM or CDMA networks APPLICATIONS e Building commissioning e Building balancing e Testing HVAC equipment performance FEATURE OUTLINE Speaker Backlit Volume touchscreen buttons LCD Power sleep button Home button DWYER INSTRUMENTS INC Headphone connection with integral protective rubber cap USB connection for data transfer or recharging with integral protective rubber cap Reset button Figure 1 P O BOX 373 MICHIGAN CITY INDIANA 46360 U S A Display 4 3 QHD Gorrilla glass touch screen 960x540 Wireless Distance 50 15 m or greater Response Time 1 s Temperature Limits Operating 4 to 140 F 20 to 60 C Storage 40 to 176 F 40 to 80
2. 1 0 FPM 247 C 13 3 RH Anemometer FPM 250 200 E Figure 8 The measurements are normally displayed as a digital meter If desired the measurements can be shown as an analog gauge or as a graph by touching the three lines in the top left and choosing the desired option Preferences and parameters can also be adjusted in this menu amp Sensors Gauge Mode List Mode VP2 000042 Gauge Mode Graph Mode Touch to Preferences access fa parameters Figure 9 In the Preference Menu users can select which parameter will be displayed larger on the screen by checking the box next to Priority Also the user can select the function of the parameter engineering units and logging method The name of the probe can be changed and calibration data if available will be displayed Pressing the arrow in the top left will return to the active probe list Preferences Temperature 30 0 C 60 0 C Priority Units c Logging Touch to make parameter priority Manual Duration Duration 1 min Anemometer 0 0 FPM 5054 0 FPM Priority Function Velocity Units FPM Logging l Touch to change Manual Duration logging method Touch to change units Duration 1 min Humidity 0 0 RH 100 0 RH Priority 0 Function Relative Humidity Figure 10 Logging can be initiated in any of the above views by either pressing the button on the probe or by pulling up on the red square on the bottom and
3. C Humidity Limits 5 to 95 RH Power Requirements 2000 mAh lithium ion battery installed functional non replaceable Memory RAM 1G amp ROM 4G Operating System Android 4 2 2 CPU MTK6589W Quad Core 1 2 GHz Enclosure Rating IP68 Weight 15 9 oz 450 g Agency Approvals CE FCC compliant Camera Belt clip Bi color Speaker LED SIM card access Power button USB charger connector Hand strap clip Phone 219 879 8000 Fax 219 872 9057 www dwyer inst com e mail info dwyermail com OPERATION Powering On Off To turn on the unit press and hold the power button Wait approximately 15 seconds for it to fully power on Swipe to unlock the unit To turn off the unit either press and hold the power sleep button and press Power Off when prompted on the LCD or press the reset button Battery The Model UHH2 utilizes an internal rechargeable battery The battery symbol in the top right of the screen shows the status of the battery NOTICE When the UHH2 is received it will only have a partial charge Use the included USB charging cable and charging block to charge the unit to full battery before using When the battery is low the battery symbol will turn red When this occurs use the included USB charging cable and charging block to charge the unit NOTICE The UHH2 comes factory paired to the included UHH BTG Wireless Mobile Gateway Before pairing a new wireless gateway the current one should b
4. e selection screen can always be accessed by pressing the three lines in the top left of the Mobile Meter app and going to Setup The past paired probes and modules will be stored in this list as well Probes or modules that are currently unavailable will be in grey but they can still be selected to display when they become active To delete or rename a probe in this screen simply press and hold the probe and click on the desired option Pressing the arrow next to Setup in the top left of the screen will return to the active probes list Touch to select probe Touch to go back to previous menu VP2 000042 6 L Press and hold to delete or rename probe Figure 6 NOTICE It is recommended that only four probes be selected due to the bandwidth limitations between the UHH2 and the gateway This active probe list will give the probe names and the measurement data for all of the selected probes Additional information such as low battery warnings of the probes and the communication status is available on the screen Mobile Meter VP2 090042 0 0 rp 23 5 C 16 9 RH Probe name Connection status Green connected Red not connected RP2 Q907A3 Probe type Figure 7 Any of the probes can be made full screen by touching the desired probe In the full screen view users can scroll through the active probes by swiping the screen to the left or right List Mode VP2 000042
5. e unpaired Pairing to the Mobile Gateway In order to pair the Model UHH2 to the Model UHH BTG Wireless Mobile Gateway first turn on the gateway by pushing the power button See Figure 1 Next either open the Mobile Meter app or go directly to the Bluetooth menu in the settings menu on the device The bridge is automatically discoverable once it is turned on Select the device named PROBEBRIDGE followed by the serial number of your gateway If prompted for a pass code type in 0000 Once the gateway is paired to the UHH2 the blue LED on the gateway will flash when communications are transmitted between the UHH2 and UHH BTG EA Bluetooth W63 Only visible to paired device PAIRED DEVICES PROBEBRIDGE_2F2F6B AVAILABLE DEVICES P01 010142 Please enter the Bluetooth Touch to settings and pair with your probe bridge go to Go to Bluetooth Settings Bluetooth menu SEARCH FOR DEVICES Figure 2 Pairing Probes or Modules to Gateway The wireless probes and modules automatically become discoverable to the gateway when they are turned on if they are not already connected to another gateway or Model UHH UHH2 base unit You must be in the Mobile Meter or other Dwyer Instruments Inc approved app to see which probes are paired The blue LED on the gateway and the green LED on the probe will flash rapidly when there is communication between the probe and the gateway Mobile Meter App Operation The Dwyer Mobile Meter app i
6. ept 1 5 cm from the body To maintain compliance with FCC RF exposure requirements use accessories that maintain a 1 5 cm separation distance between the user s body and the back of the handset The use of belt clips holsters and similar accessories should not contain metallic components in its assembly The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements and should be avoided This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interface received including interference that may Cause undesired operation NOTE The manufacturer is not responsible for any radio or TV interference caused by unauthorized modification to this equipment Such modifications could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation I
7. f this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one of more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help MAINTENANCE REPAIR Upon final installation of the Model UHH2 no routine maintenance is required The Model UHH2 is not field serviceable and should be returned if repair is needed Field repair should not be attempted and may void warranty WARRANTY RETURN Refer to Terms and Conditions of Sale in our catalog and on our website Contact customer service to receive a Return Goods Authorization Number before shipping the product back for repair Be sure to include a brief description of the problem plus any additional application notes Android is a registered trademark of Google Inc FR 44431 Ee 1 Phone 219 879 8000 www dwyer inst com Fax 219 872 9057 e mail info dwyermail com
8. pressing Log If the logging is set to duration which can be set in the Preferences menu it will log continuously for the set duration Sensors VP2 000042 30 FPM 75 9 F 13 6 RH Anemometer FPM 200 f Points Logged save log file Figure 11 Copyright 2015 Dwyer Instruments Inc DWYER INSTRUMENTS INC P O BOX 373 MICHIGAN CITY INDIANA 46360 U S A Printed in U S A 6 15 In order to end a log file press the Save Log button on the bottom of the screen The log can then be either viewed shared or closed In order to view the log file touch Open Log To share the log file select to share the file via wireless communication to another device email the file directly from the phone or share it via Wi Fi to another device on the same network Otherwise touching OK will close the file for later access storage sdcard0 dwyer VP2 000042 VP2 000042 Fri Jan 16 14 07 31 CST 2015 csv Continue Logging Save Log 01 4 Share Log Open Log Figure 12 FCC RF EXPOSURE INFORMATION AND STATEMENT The SAR limit of USA FCC is 1 6 W kg averaged over one gram of tissue Device types S09 FCC ID ZHN W63 has also been tested against this SAR limit The highest SAR value reported under this standard during product certification for use at the ear is 0 430 W kg and when properly worn on the body is 0 772 W kg This device was tested for typical body worn operations with the back of the handset k
9. s located in the top left of the unit s main screen Click on the icon to open the app Note When the app is opened an error message will pop up This can be bypassed by pressing OK and can be permanently stopped by adding a Google Play account in the device s settings menu Upon opening the Mobile Meter app you will see Get Started if the Wireless Mobile Gateway is paired to the device Dwyer Get Started Touch to get started Figure 3 The app also has a demo mode which can be selected at this time which allows users to familiarize themselves with the app and its functions before connecting their own instruments To leave demo mode and enter measurement mode press the back button until the main screen is up then press Get Started and press No on the box that pops up Would you like to run the demo mode Show this dialog next time Touch to enter measurement mode Touch to enter demo mode Yes No Figure 4 During the first time using the app no probes will be paired yet It will prompt to go to the probe set up menu to find available probes If they aren t already turn on the probes or modules at this time to make them discoverable Mobile Meter Touch to No probes attached set up probes en Go to Settings Figure 5 The probe list automatically refreshes to show any new probes Select the desired probes or modules by touching the box on the right side of the screen The prob