1. Figure 4 SCB 19 Mounting Screw Holes NATIONAL MIN SCB 19 INSTRUMENTS P N 151899A 01L Prod of U S A S N 1111111 carpets WV 0 ZOACE 5V lt _ 2 5 in 63 5 mm _ gt 1 DIN Rail Mounting Screw Holes 2 Wall Mounting Screw Holes SCB 19 User Guide National Instruments 5 Specifications Physical Dimensions cecccceeesecesceeesseeesttessneeseseceeaees Environmental Operating environment Relative humidity range Pollution Degree Altitude Indoor use only Storage environment Ambient temperature range Relative humidity range Note Clean the device with a soft 8 7 x 8 7 x 3 1 cm 3 4 x 3 4 x 1 2 in 355 g 12 5 oz H19 and screw terminals 0 C to 55 C in accordance with IEC 60068 2 1 and IEC 60068 2 2 10 to 90 noncondensing in accordance with IEC 60068 2 56 2 2 000 m 20 C to 70 C in accordance with IEC 60068 2 1 and IEC 60068 2 2 5 to 95 noncondensing in accordance with IEC 60068 2 56 non metallic brush Make sure that the device is completely dry and free from contaminants before returning it to service Shock and Vibration Operational shock Random vibration Operating Nonoperating 6 ni com SCB 19 User Guide 30 g peak half sine 11 ms pulse in accordance with IEC 60068 2 27 Test profile developed in accordance with MIL PRF 28800F 5 Hz to 500 Hz 0 3 gins 5
2. Electrical and Electronic Equipment WEEE K EU Customers At the end of the product life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee EFAA mis Real SDE ChE RoHS QO RAA National Instruments 46 p E E TAE a P REE EEA ES ROHS XF National Instruments FE ROHS AHERE WK ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china SCB 19 User Guide National Instruments 7 Where to Go for Support The National Instruments website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request atni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office web
3. Hz to 500 Hz 2 4 gins in accordance with IEC 60068 2 64 Nonoperating test profile exceeds the requirements of MIL PRF 28800F Class 3 Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use e JEC 61010 1 EN 61010 1 e UL 61010 1 CSA 61010 1 Note For UL and other safety certifications refer to the product label or the Online Product Certification section CE Compliance CE This product meets the essential requirements of applicable European Directives as follows e 2006 95 EC Low Voltage Directive safety e 2004 108 EC Electromagnetic Compatibility Directive EMC Online Product Certification To obtain product certifications and the Declaration of Conformity for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to the MI and the Environment Web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste
4. PFI Screw Terminals 4 Cable Tie Loops 2 Ground Terminals 5 Cable Tie 3 Wall Mounting Screw Holes Getting Started with the SCB 19 Complete the following steps to connect and use your SCB 19 with your NI device 1 Install your NI device in your chassis Refer to your device documentation for installation instructions 2 Remove the four cover screws with a Phillips 1 screwdriver and open the top cover as shown in Figure 1 3 Connect wires to the screw terminals by stripping 6 35 mm 0 25 in of insulation inserting the wires into the screw terminals and securely tightening the screws with the flathead screwdriver to a torque of 0 5 N m to 0 6 N m 4 43 Ib in to 5 31 Ib in A Caution To ensure the EMC performance specified for the connected device any wires connected to screw terminals that exit the enclosure must be shielded NI recommends using a multiconductor cable with an overall shield Terminate the cable shield to one of the PCB mounting screws Note The top row of screw terminals corresponds to the DIO and PFI signals on the AUX I O front panel connector The bottom row provides ground terminals SCB 19 User Guide National Instruments 3 through one of the slots shown in Figure 2 wrapping the cable tie around the wires and tightening the cable tie Q Tip You can neaten the wires and provide mechanical support by sliding a cable tie 4 C
5. USER GUIDE SCB 19 19 Pin Shielded Desktop Connector Block This document describes how to connect and use the SCB 19 with the AUX I O front panel connector on your National Instruments device Figure 1 shows the parts of the SCB 19 connector block Figure 1 SCB 19 Connector Block 1 SCB 19 2 Cover Screws Qy NATIONAL gt INSTRUMENTS Required Supplies In addition to the SCB 19 kit you need the following supplies to connect and use your SCB 19 with your NI device NI FlexRIO adapter module or other NI device with compatible 19 pin AUX I O front panel connector SHH19 H19 AUX cable assembly NI part number 152629 0x Phillips 1 screwdriver 0 125 in flathead screwdriver Shielded multiconductor cable with 14 30 AWG wire Wire cutters Wire insulation stripper Note These supplies are not included in the SCB 19 kit You must purchase these items separately 2 ni com SCB 19 User Guide Screw Terminal Diagram Figure 2 shows the interior of the SCB 19 including the screw terminals and their corresponding signals Figure 2 Interior of the SCB 19 N J SS e m e ea ae DDDDDDDDDODDODOJTE 012 3 0 1 2 3 0 1 2 3 5v DIO PORT 0 DIO PORT 1 PFI gt O UPPER ROW SHOWN LOWER ROW ALL GROUND isn Tees XY 6 Oa or E 1 DIO and
6. lose the top cover and tighten the four cover screws A Caution Refer to your device documentation for maximum voltage specifications Using voltages outside of the specified range could damage the SCB 19 and any devices connected to it NI is not liable for any damage resulting from using voltages outside of the recommended range 5 Connect the SCB 19 to the AUX T O front panel connector on your NI device using an SHH19 H19 AUX cable NI part number 152629 0x and tighten the target screw as shown in Figure 3 Figure 3 SCB 19 Cable Connection 1 SCB 19 3 SHH19 H19 AUX Cable Assembly 2 Target Screw Caution Although the AUX I O front panel connector accepts a standard HDMI cable a standard HDMI cable causes significant crosstalk between some channels Use the SHH19 H19 AUX cable to minimize crosstalk When you have finished using the SCB 19 power off any external signals connected to the SCB 19 before you power off your computer 4 ni com SCB 19 User Guide SCB 19 Mounting Holes You can mount the SCB 19 either vertically or horizontally on a DIN rail in an industrial environment You can purchase a compatible DIN rail kit from NI using the part number 781740 01 The SCB 19 also has two screw holes for a generic wall mount These wall mount holes are designed for use with a 4 or 6 panhead screw with a minimum length of 0 625 in 15 88 mm Figure 4 shows the screw holes locations on the bottom of the SCB 19
7. sites which provide up to date contact information support phone numbers email addresses and current events LabVIEW National Instruments NI ni com the National Instruments corporate logo and the Eagle logo are trademarks of National Instruments Corporation Refer to the Trademark Information at ni com trademarks for other National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patents Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the NI FlexRIO Readme Refer to the Export Compliance Information at ni com 1legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data 2012 National Instruments All rights reserved 375902B 01 Sep12