Home
D-ILA PROJECTOR
Contents
1. Communication Examples When specifying 50 decimal as the phase adjust level CTLR 77 P SP UOP SP 0032 CR DLA 1 SP 0 CR When requesting the current phase adjust level if phase adjust level is set to decimal CTLR 2 1 SP U04 CR DLA 1 SP 0 SP 0000 CR 12 5 Tracking U05 55H 30H 35H Definition Adjusts tracking Command 005655H 30H 35H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 50 decimal as tracking adjust level CTLR 77 1 SP UOS SP 0032 CR DLA 1 SP 0 CR When requesting current tracking adjust level data if tracking adjust level is set to 0 decimal CTLR 7 1 SP UOS CR DLA 1 SP 0 SP 0000 CR 12 6 Contrast U06 55H 30H 36H Definition Adjusts the contrast Command U06 55H 30H 36H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 2 decimal as the contrast adjust level CTLR vP 7 SP U06 SP 0002
2. Definition Requests vertical frequency of picture that is projected Command USD55H 33H 44H Parameter type Numeric Repiy time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When requesting vertical frequency if vertical frequency is 60Hz CTLR 7 1 SP U3D CR DLA 1 SP 0 SP 003C CR 47 12 33 Horizontal Resolution Query U3E 55H 33H 45H Definition Requests horizontal resolution of picture that is prolected Command USE 55H 33H 45H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When requesting horizontal resolution if horizontal resolution is 1280 CTLR 7 71 SP U3E CR DLA 1 SP 0 SP 0500 CR 48 12 34 Vertical Resolution Query U3F 55H 33H 46H Definition Requests vertical resolution of picture that is prolected Command USF 55H 33H 46H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X
3. Communication Examples When requesting vertical resolution if vertical resolution is 1024 CTLR 7 1 SP U3F CR DLA 1 SP 0 SP 0400 CR 49 12 35 Keystone Correction of trapezoid distortion U40 55H 34H 30H Definition Correction of Keystone Command 0407 55H 34H 30H Parameter type Numeric Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 0 decimal as keystone CTLR 77 7 SP U40 SP 0080 CR DLA T SP 0 CR When requesting the keystone if the keystone is set to 0 decimal CTLR 7 1 SP U40 CR DLA 1 SP 0 SP 0080 CR 50 12 36 Operation Mode Query ZO3 5AH 30H 33H Definition Requests current operation mode Command Z03 5AH 30H 33H Parameter type Reply time 3seconds Conditions Query only Operation mode Special parameter Refer to 7 3 6 Projector Operation Mode Parameter Standby mode O Power ON mode O Cool down mode O Emergency mode O When the POWER OFF command is received in the Power ON mode the Projector first enters the Cool Down mode then automatically enters the Standby mode For information on each operation mode refer to 10 Projector Operation Modes POWER ON command cannot be accepted i
4. CR DLA 1 SP 0 CR When requesting current contrast adjust level data if contrast adjust level is set to 0 decimal CTLR 2 1 SP 06 CR DLA 1 SP 0 SP 0000 CR 20 12 7 Brightness U07 55H 30H 37H Definition Adjusts the brightness Command U07 55H 30H 37H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 2 decimal as the brightness adjust level CTLR Po SP UO SP FFFE CR DLA O T SP 0 CR When requesting current brightness adjust level data if brightness adjust level is set to O decimal CTLR 7 1 SP UO CR DLA 1 SP 0 SP 0000 CR 21 12 8 Sharpness U08 55H 30H 38H Definition Adiusts the sharpness Command U08 55H 30H 38H Parameter type Numeric Reply time 3seconds Conditions Video Sources Areas Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 2 decimal as the sharpness CTLR P SP UO8 SP 0002 CR DLA 1 SP 0 CR When requesting current sharpness adjust level data if sharpness adjust level is set to 7 decim
5. Cool down mode Emergency mode X O X X Communication Examples When selecting NTSC as the broadcast system CTLR PT SP U19 SP 0 CR DLA 1 SP 0 CR When requesting the current broadcast system setting if the broadcast system is set to PAL CTLR 1 SP 19 CR DLA 1 SP SP 2 CR 35 12 22 Input Select U1A 55H 31H 41H Definition Selects the video input terminals Command U1A 55H 31H 41H Parameter type Special parameter Refer to 7 3 5 Input Select Parameter Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When selecting D SUB as the video input CTLR PT SP U1A SP 3 CR DLA 1 SP 0 CR When requesting the current video input setting if the video input is selected CTLR T 1 SP CR DLA 1 SP SP 1 CR 36 12 23 Transfer Rate U1B 55H 31H 42H Definition Controls the transfer rate for RS 232C Command UTB 55H 31H 42H Parameter type Special parameter Refer to 7 3 2 Transfer Rate Parameter Reply time 3seconds Conditions Operation mode Standby mode Povver ON mode Cool down mode Emergency mode O O O X After this command has been received and processed correctly the Tally Response Dat
6. UOB 55H 30H 42H Parameter type Special parameter Refer to 7 3 4 Color Temperature Parameter Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying MIDDLE as the color temperature CTLR P 7 SP UOB SP 1 CR DLA 1 SP 0 CR When requesting current color temperature data if color temperature is set to LOVV CTLR To 1 SP UOB CR DLA T SP 0 SP O CR 25 12 12 R Gain U0C 55H 30H 43H Definition Adiusts the R gain Command UOCU55H 30H 43H Parameter type Numeric Reply time 3seconds Conditions Computer Sources Areas Operation mode X O X X Standby mode Power ON mode Cool down mode Emergency mode Communication Examples When specifying 2 decimal as the R gain adjust level CTLR PTP 1 SP UOC SP FFFE CR DLA T SP 0 CR When requesting current R gain adjust level data if R gain adjust level is set to 128 decimal CTLR 7 1 SP UC CR DLA 1 SP 0 SP 0080 CR 26 12 13 G Gain U0D 55H 30H 44H Definition Adiusts the G gain Command UOD 55H 30H 44H Parameter type Numeric Reply time 3seconds Conditions Computer Sources Areas Ope
7. 1 70 CR SP Parameter None Tally response data format to query a KI SP Normal Termination Status SP Parameter CR Parameter 12 byte ASCII characters are used for Model and Software version information MMMMMMMXXXXX Softvvare version Model Model HEX Definition D03 44H 30H 33H 2DH 2DH 2DH 2DH DLA G3010 Series Projector M2000 4DH 32H 30H 30H 30H 2DH 2DH DLA M2000 Series Projector Communication Example When the projector is a M2000 series projector with software version 1 2 1 CTLR 9 1 SP ZOA CR DLA a 17 SP 0 SP M2000 001217 CR 53 12 39 Switcher Selection V00 57H 30H 30H Definition Changes channels according to commands from the Switcher When Projector receive the command Projector switches input terminal to RGB And Source to be matched to input switching number among presetted Sources is displayed When it is not set up or not being matched the source inputted now is newly set up Command VVOO 57H 30H 30H Parameter type The Switcher s input switching number Refer to 7 3 11 Switcher Number Parameter Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying
8. Command U207 55H 32H 30H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Example When setting the volume adjust level to 30 CTLR Yo SP U20 SP 001E CR DLA 1 SP 0 CR When requesting the current volume adjust level setting if the volume level is set to 5 CTLR 7 1 SP U20 CR DLA 1 SP 0 SP 7005 CR 41 12 27 Quick Alignment U2A 55H 32H 41H Definition Controls the quick alignment function Command U2A 55H 32H 41H Parameter type Reply time 3seconds Conditions Except when there is no Source Area signal Normal Tally Data is returned when query Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Quick Alignment Parameter Use only OFF parameter for ON OFF Quick alignment parameter Character HEX OFF 0 30H The Projector performs quick alignment processing after returning Normal Termination Status Tally Response data Therefore after OFF command transmission send the following command after waiting for fixed time about 3 seconds or more Communication Example More than 3 sec lt Possible to transmit next command CTLR 1
9. Definition Controls the aspect ratio of the projected image Command U2E 55H 32H 45H Parameter type Special parameter Refer to 7 3 8 Aspect Parameter Reply time 3seconds Conditions Video Sources Areas Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When setting the aspect ratio to 4 3 CTLR 7 1 SP U2E SP 0 CR DLA 1 SP 0 CR When requesting the current aspect ratio setting if the aspect ratio is set to 16 9 CTLR T 1 SP UZ CR DLA 1 SP SP 1 CR 45 12 31 Horizontal Frequency Query U3C 55H 33H 43H Definition Requests horizontal frequency of picture that is prolected Command U3C 55H 33H 43H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When requesting horizontal frequency if horizontal frequency is 64 3kHz CTLR 7 1 SP U3C CR DLA 1 SP 0 SP 0287 CR Note Horizontal Frequency is 10 times of data to be returned from Projector This example shows 283 in hexadecimal which is 643 in decimal Horizontal Frequency of Projected image is 643 10 64 3kHz 46 12 32 Vertical Frequency Query U3D 55H 33H 44H
10. ID Parameter Character HEX Definition m 30 ID O global command for all projectors T 31 ID 1 32 2 3 33 D 3 4 34 ID 4 5 35 ID 5 14 36 ID 6 T 37 ID 7 e 38 ID 8 9 39 ID 9 A 41 ID 10 B 42 ID 11 43 ID 12 44 ID 13 E 45 ID 14 F 46 ID 15 7 3 11 Switcher Number Parameter Character HEX Definition 0001 30H 30H 30H 31H Switcher No 1 0002 30H 30H 30H 32H Switcher No 2 0003 30H 30H 30H 33H Switcher No 3 0004 30H 30H 30H 34H Switcher No4 0005 30H 30H 30H 35H Switcher No 5 0006 30H 30H 30H 36H Switcher No 6 0007 30H 30H 30H 37H Switcher No 7 0008 30H 30H 30H 38H Switcher No 8 0009 30H 30H 30H 39H Switcher No 9 000A 30H 30H 30H 41H Switcher No 10 8 TALLY RESPONSE DATA The Projector will only accept and process data when the ID number included with the data coincides with the ID number registered to the Projector itself Except when ID 0 If the received ID number matches the Projector s ID it will return a response to the query from the external control unit This response data is called Tally Response Data However when ID 0 tally response data is not replied The Tally Response Data is normally returned within 3 seconds after the data is received There are some exceptions however e g POWER command After transmitting
11. When specifying 30 decimal as the horizontal position CTLR 77 1 SP U02 SP 001E CR DLA T SP 0 CR When requesting current horizontal position data if horizontal position is set to 1 CTLR 7 1 SP U02 CR DLA 1 SP 0 SP FFFF CR When specifying the horizontal position but the Source Area has no signal input CTLR 77 1 SP U02 SP 001E CR DLA 1 SP A05 CR 12 3 Vertical Position U03 55H 30H 33H Definition Adiusts the vertical position Command U03 55H 30H 33H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 5 decimal as the vertical position CTLR 77 7 SP U03 SP 0005 CR DLA 1 SP 0 CR When requesting current vertical position data if vertical position is set to 16 decimal CTLR 7 1 SP U03 CR DLA 1 SP 0 SP 0010 CR 12 4 Phase U04 55H 30H 34H Definition Adjusts the phase Command U04 55H 30H 34H Parameter type Numeric Reply time 3seconds Conditions Eexcept when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X
12. an internal errors other than IIC ACK errors occur In this case however the parameter s numeric value has no meaning 1F20H Ex Internal error data when IIC ACK error occurs with Slave address AOH and Sub address of SID SP E03 SP 00A0 SP 1F207 CR 9 3 Internal Error Data Reply Timing When returning data the Projector checks for internal error data If such data exists the internal error data is returned before the tally response data is transmitted That is if an internal error occurs the Projector retains the internal error data returning it in order of precedence a request for tally response data is received Once transmitted internal error data is deleted from the Projector 10 PROJECTOR OPERATION MODES This section describes the Projector s four basic operation modes 10 1 Standby Mode The Projector enters this mode when it is plugged into an AC outlet and the MAIN POWER switch is turned ON The lamp does not light and the fans do not operate 10 2 Power ON Mode This mode is engaged when the POWER ON command is received and processed normally in the Standby mode The lamp is lighted and the fans start rotating Images can be projected in this mode 10 3 Cool Down Mode This mode is engaged when the POWER OFF command is received and processed normally in the Power ON mode The lamp goes out and the fans are
13. 7 55H 31H 37H Parameter type ONZ OFF Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool down mode Emergency mode O O O X Communication Examples When reversing the image horizontally Right Left reverse CTLR PT SP SP 1 CR DLA 1 SP 0 CR When requesting the current R L reverse setting if the image is not reversed horizontally CTLR 7 1 SP 17 CR DLA 1 SP SP 0 CR 33 12 20 Top Bottom Invert U18 55H 31H 38H Definition nverts the image vertically Command U18 55H 31H 38H Parameter type ONZ OFF Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool down mode Emergency mode O O O X Communication Examples When inverting the image vertically Top Bottom invert CTLR P P SP U18 SP 1 CR DLA 1 SP 0 CR When requesting the current Top Bottom invert setting if the image is not inverted vertically CTLR 7 1 SP U18 CR DLA 1 SP SP 0 CR 34 12 21 Decoder U19 55H 31H 39H Definition Selects the color TV broadcast system Command 019 55H 31H 39H Parameter type Special parameter Refer to 7 3 3 Decoder Parameter Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode
14. D ILA PROJECTOR DLA G30 1 Oseries DL A M 2 O O Oseries RS 232C CONTROL SPECIFICATIONS Victor Company of Japan Limited D ILA is a trademark of Victor Company of Japan Limited Document Number CTGKE 0013 10 11 12 13 CONTENTS 0070067 es 2 Communication Foradada 2 Da e ten hehe 2 A 0000000000 0000000000 0000 4 ib a LADI uba 4 RZ 0002001007 0 5 PAM ds 5 Tally Response Data imita a nad 9 Internal A a ia 10 Projector Operation Modes ooocccocccoccconcconcconcccnnononononnnnnncnnncnnnnnnnnnnnncinncinnennnncinncinnenenes 12 OU Citation 13 Commands uti APA RA A Ad a 14 APPO DORA A AR Ra ee ee ee 55 1 OUTLINE This document describes the communication and data formats used to control the projector via its RS 232C port 2 COMMUNICATION FORMAT Transfer Rate 9600 19200 default bps Data Length 8 bits Parity Bit None Start Bit 1 bit Flow Control None 3 DATA FORMAT 3 1 Command Data Format External Control to Projector Header ID sP Command sP Parameter sP Parameter sP ace CR Header Indicates the beginning of data and data type T 21H Command for the Projector 3FH Query to the Projector Request for data ID Identification number of Projector SP Indicates the separation between ID and co
15. FE 46H 46H 46H 45H 7 2 ON OFF Status Parameter Indicates the ON OFF status of items such as POWER or HIDE Character HEX Definition 0 30 OFF T 31 ON 7 3 Special Parameters Parameters other than those described in 7 1 to 7 2 7 3 1 7 3 2 7 3 3 7 3 4 7 3 5 Menu Display Auto OFF Parameter Character HEX Definition 0 30 NO 1 31 YES Transfer Rate Parameter Character HEX Definition 0 30 9600bps 1 31 19200bps Decoder Parameter Character HEX Definition 0 30 NTSC 1 31 NTSC4 43 2 32 PAL 33 SECAM Y 34 AUTO Color Temperature Parameter Character HEX Definition 0 30 LOW 1 31 MIDDLE 2 32 HIGH Input Select Parameter Character HEX Definition 0 30 Y C T 31 VIDEO Y 33 D SUB Y 34 BNC 7 3 6 Projector Operation Mode Parameter Character HEX Definition 0000 30H 30H 30H 30H Standby Mode 0001 30H 30H 30H 31H Power ON Mode 0002 30H 30H 30H 32H Cool Down Mode 10004 30H 30H 30H 34H Emergency Mode 7 3 7 Text Mode Parameter 7 3 8 Character HEX Definition 0 30 Text 1 1 31 Text 2 2 32 Text 3 Y 33 Text 4 Y 34 Text 5 Aspect Parameter Character HEX Definition 0 30 4 3 1 31 16 9 7 3 9 Resize Parameter Character HEX Definition 0 30 1 1 1 31 Full 2 32 Aspect 7 3 10
16. H 32H 45H Horizontal Frequency Query U3C 55H 33H 43H Vertical Frequency Query U3D 55H 33H 44H Horizontal Resolution Query U3E 55H 33H 45H Vertical Resolution Query U3F 55H 33H 46H Keystone U40 55H 34H 30H Operation Mode Query Z03 5AH 30H 33H Source Query Z05 5AH 30H 35H Model Status ZOA 5AH 30H 41H Switcher Selection VVOO 57H 30H 30H 56 13 2 RS 232C Port Pin Configuration RS 232C Control Port D SUB 9 pin Male Pin No Signal Definition 1 N A Not used 2 RxD RD Receive data 3 TXD SD Transmit data 4 N A Not used 5 GND GND 6 N A Not used 7 N A Not used 8 N A Not used 9 N A Not used 57
17. Internal Error Data Format Projector to External Control Header ID SP Internal Error Status SP Parameter SP Parameter SP CR Header Indicates the beginning of the internal error data E 26H ID Identification of Projector SP Indicates the separation between ID and status status and parameter parameter and parameter 20H Internal Error E01 45H 30H 31H Status E02 45H 30H 32H E03 45H 30H 33H E04 45H 30H 34H E06 45H 30H 36H E07 45H 30H 37H E08 45H 30H 38H E09 45H 30H 39H EOB 45H 30H 42H EOC 45H 30H 43H ETT 45H 31H 31H E12 45H 31H 32H E20 45H 32H 30H CR Indicates the end of the data 0DH For details on internal error status refer to 9 Internal Errors 4 HEADER ndicates the beginning and type of communication data 4 1 External Control to Projector Character HEX Definition T 21 Command to the Projector 2 3F Query request for information to the Projector 4 2 Projector to External Control Character HEX Definition 40 Tally Response data 26 nternal error data 5 ID Numeric characters are used to identify an individual Projector when two or more Projector units are connected to a single control machine Setting separate identification
18. SP U2A SP 0 CR S 1 SP Z03 CR DLA Q 1 SP 0 CR 42 12 28 Text Mode U2C 55H 32H 43H Definition Controls the legibility of screen text Command 1 2 55 32H 43H Parameter type Special parameter Refer to 7 3 7 Text Mode Parameter Reply time 3seconds Conditions Computer Sources Areas Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When setting the text mode to Normal CTLR vo SP U2C SP 0 CR DLA 1 SP 0 CR When requesting current text mode setting if the text mode is set to Text 1 CTLR 7 1 SP U2C CR DLA 1 SP SP 1 CR 43 12 29 Resize U2D 55H 32H 44H Definition Controls expanded image Command U2D 55H 32H 44H Parameter type Special parameter Refer to 7 3 9 Resize Parameter Reply time 3seconds Conditions Computer Sources Areas Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When setting the resize function to 1 1 CTLR P 7 SP U2D SP 0 CR DLA 1 SP 0 CR When requesting the current resize function setting if the resize function is set to Full CTLR 7 1 SP UD CR DLA 1 SP 0 SP 1 CR 44 12 30 Aspect Change U2E 55H 32H 45H
19. Switcher 2 if a channel specifying input switcher 2 exists CTLR P 1 SP VOO SP 0002 CR DLA 1 SP 0 CR When requesting the current Switcher No if Switcher does not connected CTLR 1 SP 00 CR DLA 1 SP 0 SP 0000 CR 54 13 APPENDIX 13 1 External Control Command List Command Character HEX Hide UOO 55H 30H 30H Horizontal Position U02 55H 30H 32H Vertical Position U03 55H 30H 33H Phase U04 55H 30H 34H Tracking 4 05 55H 30H 35H Contrast U06 55H 30H 36H Brightness UO7 55H 30H 37H Sharpness U08 55H 30H 38H Color U09 55H 30H 39H Tint UOA 55H 30H 41H Color Temperature UOB 55H 30H 42H R Gain UOC 55H 30H 43H G Gain UOD 55H 30H 44H B Gain UQE 55H 30H 45H Power UOF 55H 30H 46H Menu Auto Off U10 55H 31H 30H Line Display U11 55H 31H 31H Sleep Time 412 55 31H 32H Right Left Reverse U17 55H 31H 37H Top Bottom Invert U18 55H 31H 38H Decoder U19 55H 31H 39H Input Select 55H 31 41H Transfer Rate U1B 55H 31H 42H Lamp Time UTC 55H 31H 43H D UTD 55H 31H 44H 55 Volume U20 55H 32H 30H Quick Alignment U2A 55H 32H 41H Text Mode U2C 55H 32H 43H Resize U2D 55H 32H 44H Aspect Change U2E 55
20. a is returned at the nevv transfer rate Communication Examples When changing the transfer rate to 9600 bps from the current setting of 19200 bps CTLR DLA P 7 SP U1B SP 0 CR T SP 0 CR c eee 19200bps until this point 9600bps from here on The default transfer rate setting is 19200bps 37 12 24 Lamp Time U1C 55H 31H 43H Definition Reset check the lamp operation Command UTC 55H 31H 43H Parameter type Reply time 3seconds Conditions Operation mode A When resetting Standby mode Power ON mode Cool down mode Emergency mode O X X X A When requesting current time Standby mode Power ON mode Cool down mode Emergency mode O O O X Data Format A Reset data format 171F17 1 SP FUIC SP Reset Parameter CR Reset parameter 1017 5BH 28H 29H 5DH Never issue the Reset command unless the lamp has been replaced with a new one A Tally Response data format when requesting current time a 11 SP Normal Termination Status SP Parameter 1 SP Parameter 2 CR Parameter1 The Projector has an incremental counter which counts Lamp Operation Time at 1 time in every 4 minutes Parameter 1 shows this counter value The parameter type is numeric Actual
21. al CTLR 2 1 SP U08 CR DLA 1 SP 0 SP 0007 CR 22 12 9 Color U09 55H 30H 39H Definition Adjusts the color Command U09 55H 30H 39H Parameter type Numeric Reply time 3seconds Conditions Video Sources Areas Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 2 decimal as the color adjust level CTLR 7 1 SP U09 SP FFFE CR DLA 1 SP 0 CR When requesting current color adjust level if color adjust level is set to 0 decimal CTLR 7 1 SP U09 CR DLA T SP 0 SP 9000 CR 23 12 10 Tint U0A 55H 30H 41H Definition Adjusts the tint Command UOA 55H 30H 41H Parameter type Numeric Reply time 3seconds Conditions Video Sources Areas Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 2 decimal as the tint adjust level CTLR 7 417 SP UOA SP FFFE CR DLA 1 SP 0 CR When requesting current tint adjust level data if tint adjust level is set to 0 decimal CTLR T 1 SP UOA CR DLA 1 SP 0 SP 0000 CR 24 12 11 Color Temperature U0B 55H 30H 42H Definition Adiusts the color temperature Command
22. ctor Reply Time refers to the maximum time required between command reception and return of Tally Response Data In other words it refers to the maximum time that the external control unit must wait for the Tally Response Data For details on the different parameters refer to 7 Parameters Acceptance or non acceptance of a command in each operation mode is indicated by O accept or X does not accept 12 1 HIDE U00 55H 30H 30H Definition Controls video signal muting Command U00 55H 30H 30H Parameter type ON OFF Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples To turn HIDE ON CTLR PT 7 SP UOO SP 1 CR DLA 1 SP 0 CR When requesting current HIDE status if HIDE status is ON CTLR 1 SP UOO CR DLA 1 SP SP 1 CR When trying to change HIDE status in emergency mode turn ON CTLR PT 7 SP UOO SP 1 CR DLA 1 SP A04 CR 12 2 Horizontal Position U02 55H 30H 32H Definition Adiusts the horizontal position Command 4 02 55 30H 32H Parameter type Numeric Reply time 3seconds Conditions Except when there is no Source Area signal Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples
23. data the external control unit cannot transmit subsequent data until the Tally Response Data is received However if Tally Response Data is not returned within 3 seconds after transmitting the data there are some exceptions such as the POWER command data transmission can be retried 8 1 Tally Response Data Status 8 1 1 Normal Termination Status Character HEX Definition 0 30 Command received and processing terminated 8 1 2 Status when Error Occurs Error Status Character HEX Definition A00 41H 30H 30H Command not supported A01 41H 30H 31H Invalid parameter A02 41H 30H 32H Parameter value exceeds operation range A03 41H 30H 33H Unclassified error Unacceptable command in current mode A04 41H 30H 34H Tor Unacceptable command with current setting 05 41H 30H 35 Command cannot be accepted if no signal AOA 41H 30H 41H Time out occurred with the communication with sub microcomputer AOB 41H 30H 42H Error occurred with the communication with sub microcomputer 8 2 Tally Response Data Parameter The Tally Response Data Parameter is returned when the Tally Response Data is issued in response to a query request for data No parameter is returned when Tally Response Data issued in response to a command or when an error occurs 9 INTERNAL ERRORS Error data is returned to the external control unit wh
24. en an error has occurred 9 1 9 2 nternal Error Data Status Internal Error Status Character HEX Definition E01 45H 30H 31H 1Lamp did not light E02 45H 30H 32H _ Lamp life exceeds guaranteed time E03 45H 30H 33H ACK error occurs E04 45H 30H 34H Filter cover on the bottom of the unit is displaced E06 45H 30H 36H Lamp suddenly goes out Lamp Shut Down while projecting in Power ON mode E07 45H 30H 37H Fan is locked E08 45H 30H 38H lnternal temperature is too high E09 45H 30H 39H 1 Temperature around air intake is going up abnormally EOB 45H 30H 42H Error occurred with the initialization of decoder E0C 45H 30H 43H lnitialization of Video Sources Areas data was failed ETT 45H31H31H Sub microcomputer is not boost up correctly E12 45H 31H 32H Initialization of DDIC DDCTRL was failed E20 45H 32H 30H Sleep time function works and lamp was lit off Internal Error Data Parameters There are two parameters for Internal Error Data Header ID SP Internal Error Status SP Parameter 1 SP Parameter 2 CR Each parameter shows the slave address Parameter 1 and Sub Address Parameter 2 when an IIC ACK error Error status E03 occurs The parameter type is numeric value Two parameters are also returned when
25. f Frequency and Resolution Video Sources are as follows NTSC 480i PAL SECAM NTSC 480p PAL 625p DTV 720p HDTV 1035i HDTV 1080i 11 1 Sources Areas and Source Numbers When inputs via a composite S VIDEO RGB When inputs via a YPbPr Source Source No Source No Source Source No Source No Character HEX Character HEX NTSC 480i 00 30H 30H NTSC 480i 80 38H 30H PAL SECAM 02 32 PAL 82 38H 32H NTSC 480p 04 30H 34H NTSC 480p 84 38H 34 PAL 625p 05 35 PAL 625p 85 8 35 DTV 720p 06 30H 36H DTV 720p 86 8 36 HDTV 1035i 07 37 HDTV 1035i 87 38H 37H HDTV 1080i 08 30H 38H HDTV 1080i 88 38H 38H 770 FO 46H 30H No Signal FP 46H 46H ources No Signal FF 46H 46H RGB signals or YPbPr signal is fed to BNC input terminal the different Source No is given even if the same type of Source X Note that the acceptance non acceptance of a command is differ depending on the Source Area actually registered on the Projector 12 COMMANDS This section describes the commands that can be used vvith the Profector lt gt In the Communication Examples the ID number registered on the Projector is represented as 1 31H o This is the default setting CTLR refers to transmissions from the external control unit and DLA refers to transmissions Tally Response Data from the Proje
26. lamp operating time is obtained by converting the Parameter 1 value into signed 2 byte binary hexadecimal and dividing it by 15 38 Parameter2 Parameter 2 shows whether the lamp replacement time is close or not based on the following calculation Lamp service life 100 hours S Lamp operating time lt Lamp service life Character HEX Lamp replacement time not close 0 Lamp replacement time close T 31H Lamp life exceeded 2 32H Communication Examples When requesting the current lamp operating time if the lamp operating time is 150 hours CTLR 7 1 SP U1C CR DLA T SP 0 SP 08CA SP 0 CR 39 12 25 ID U1D 55H 31H 44H Definition Sets the ID for the Projector Command U1TD 55H 31H 44H Parameter type Special parameter Refer to 7 3 10 ID Parameter Reply time 3seconds Conditions No query Operation mode Standby mode Power ON mode Cool down mode Emergency mode O O O X When this command is received and processed correctly the Tally Response Data is returned with the changed ID number Communication Examples When changing the ID to 7 from the current setting of 1 CTLR PT 7 SP UD SP 7 CR DLA 7 SP 0 CR Tally Response Bi is returned with New ID no 40 12 26 Volume U20 55H 32H 30H Definition Adjusts the audio volume level
27. mmand command and parameter parameter and parameter 20H CR Indicates the end of data ODH 3 2 Tally Response Data Format Projector to External Control 3 2 1 Tally Response Data when Terminated Normally Header ID SP Normal Termination Status SP Parameter SP Parameter CR Header Indicates the beginning of tally response data 40H ID Identification number of the Projector SP Indicates the separation between ID and status status and parameter parameter and parameter 20H Normal Termination 0 30H Status CR Indicates the end of data 0DH Parameter is sent when tally response data is issued in response to a query request for data There is 2 no parameter for tally response data in response to a command 3 2 2 Tally Data vvhen Error Occurs Header ID SP Error Status CR Header Indicates the beginning of the tally response data 40H ID Identification number of Projector SP Indicates the separation between ID and Status 20H Error AOO 41H 30H 30H Status A0T 41H 30H 31H 02 41H 30H 32H A03 41H 30H 33H 04 41H 30H 34H A05 41H 30H 35H AOA 41H 30H 41H AOB 41H 30H 42H CR Indicates the end of the data 0DH For details on error status refer to 8 Tally Response Data 3 3
28. n mode Emergency mode O O O X The Sleep time function automatically turns off the projector power if the no signal status continues for a specified time Available parameters Sleep time can be set to any of the following 15 min 30 min 60 min and 0 min VVhen the above times are represented as numerical parameters Character HEX 15min 000F 30H 30H 30H 46H 30min 001E 30H 30H 31H 45H 60min 003C 30H 30H 33H 43H Omin 0000 30H 30H 30H 30H The sleep time function is disabled when the time is set to O min Tally Response data format to current sleep time query a 1 SP Normal Termination Status 5 Parameter 1 5 Parameter 2 CR Parameter 1 Indicates the sleep time specified Refer to Available parameters Parameter 2 Indicates the remaining sleep time Parameter type is numeric Communication Examples When specifying 30 min as the sleep time CTLR vo SP U12 SP 001E CR DLA 1 SP 0 CR When requesting the current sleep time setting if the sleep time is set to 15 min and the remaining time is 3 min CTLR 7 1 SP U1 CR DLA 1 SP 0 SP OOOF SP 0003 CR 32 12 19 Right Left Reverse U17 55H 31H 37H Definition Reverses the image horizontally Command U1
29. n the Cool Down mode If POWER ON is requested after POWER OFF command is sent firstly the current operation mode should be asked and then if Standby Mode is confirmed POWER ON command should be sent Communication Examples When requesting the current operation mode if the Projector is in the standby mode CTLR V T DLA SP Z03 CR 11 SP 0 SP 0000 CR 51 12 37 Source Query Z05 5AH 30H 35H Definition Asks for the Source Area setting actually assigned on the Projector Command Z05 5AH 30H 35H Parameter type Refer to 11 1 Projector Sources and Source Numbers Reply time 3seconds Conditions Query only Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Example When requesting the current Source Area setting actually assigned on the Projector if Computer Sources is actually assigned CTLR 1 SP Z05 C DLA 1 SP 0 SP FO CR 52 12 38 Projector Model Query ZOA 5AH 30H 41H Definition Obtains projector model and software version information Command ZOA 5AH 30H 41H Parameter type Reply time 3seconds Conditions Query only Operation mode Standby mode Power ON mode Cool down mode Emergency mode O O O X Model status data format lt gt Requesting current projector model status
30. numbers for each Projector allows independent control of each Projector unit Assignable ID numbers 0 30H 8 38H 1 31H 9 39H 2 32H A 41H 3 33H B 42H 4 34H C 43H 5 35H D 44H 6 36H E 45H 7 37H F 46H Factory set D is 1 31H ID number 0 30H should be used when assigning all connected Projector units for batch operations This means that when assigning independent ID numbers to multiple units 15 of the 16 assignable numbers from 1 through F can actually be used for registration Please note that tally response data is not returned from the projector when the global ID assignment function 0 is used 6 CR ndicates the end of each set of data 0DH 7 PARAMETERS There are three types of parameters 1 Indicates the numeric value 2 Indicates the ON OFF status 3 Special parameter 7 1 Numeric Value Parameter Signed 2 byte hexadecimal code represented by 4 byte characters Assignable range is between 8000 and 7FFF Ex 1 The parameter indicating 20 decimal Since 20 decimal is represented as 0014 in signed 2 byte hexadecimal its parameter is 0014 30H 30H 31H 34H Ex 2 The parameter to indicate 2 decimal Since 2 decimal is represented as FFFE in signed 2 byte hexadecimal its parameter is FF
31. on Examples When turning the Projector s power ON CTLR Po Y SP UOP SP 1 CR DLA T SP 0 CR 1 When the POWER ON command is received the Projector returns the Tally Response Data after completing all the POWER ON processing operations lighting lamp rotating fans transmitting data etc In most cases the Tally Response Data should be returned within 35 to 40 seconds If it takes more time to light up or re try is done due to internal error these operations takes maximum around 100 seconds The Tally Data is returned within 100 seconds 2 When the POWER OFF command is received during Power ON mode the Projector enters the cool down mode DLA G3010 series for about 90 seconds DLA M2000L series for about 120 seconds and continue cooling DLA G20series for about 120 seconds DLA M4000L series for about 10 minutes After cool down mode is completed the Projector automatically enters the stand by mode For operation modes refer to 10 Projector Operation Modes POWER ON command cannot be accepted in the Cool Down mode If POWER ON is requested after POWER OFF command is sent firstly the current operation mode should be asked and then if Standby Mode is confirmed POWER ON command should be sent For the command to request the current operation mode refer to 12 41 Operation Mode Query 29 12 16 MENU Auto OFF U10 55H 31H 30H Definition Controls the display menu auto off func
32. ration mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 2 decimal as the G gain adjust level CTLR Po SP UOD SP FFFE CR DLA T SP 0 CR When requesting current G gain adjust level data if G gain adjust level is set to 128 decimal CTLR T 1 SP UD CR DLA 1 SP 0 SP 080 CR 27 12 14 B Gain U0E 55H 30H 45H Definition Adiusts the B gain Command UOE 55H 30H 45H Parameter type Numeric Reply time 3seconds Conditions Computer Sources Areas Operation mode Standby mode Power ON mode Cool down mode Emergency mode X O X X Communication Examples When specifying 2 decimal as the B gain adjust level CTLR PT 1 SP UOE SP FFFE CR DLA T SP 0 CR When requesting current B gain adjust level data if B gain adjust level is set to 128 decimal CTLR To 1 SP UOE CR DLA 1 SP 0 SP 0080 CR 28 12 15 POWER U0F 55H 30H 46H Definition Controls the povver Command UOF 55H 30H 46H Parameter type ONZ OFF Reply time POWER ON transmission 100seconds 1 POWER OFF transmission 3seconds 2 Conditions No query Operation mode Standby mode Power ON mode Cool down mode Emergency mode O O X X Communicati
33. rotated continuously to cool down the lamp To avoid the lamp is lighted again in short time the POWER ON command is not accepted during this mode The DLA G3010 series the Cool Down Mode time is approximate 90 seconds The lamp goes out and the fans are rotated continuously during this mode to cool down the lamp The DLA M2000 series the Cool Down Mode time is approximate 120 seconds The lamp goes out and the fans are rotated continuously during this mode to cool down the lamp After the mentioned time lapse the unit automatically enters the Standby mode 10 4 Emergency Mode This mode is engaged when the projector malfunctions or is improperly operated The lamp and the fans are shut down and the MAIN POWER switch is turned OFF Non operation status continues until the reset function is activated Standby Mode DLA G3010 Series After 120 sec Lamp cool down DLA M2000 Series POWER OFF Sleep Time Cool Down Mode AA Lamp not lit Lamp shut down Filter cover a Fiter cover Fan lock Fan lock Internal temp abnormal External temp abnormal Lamp shut down After 90 sec Lamp cool down Power ON Mode Note that the acceptance non acceptance condition of a command differs depending on the operation mode 11 SOURCE The input signals to prolectors can be Computer Sources and Video Sources Although the specific signal names are not given to Computer Sources these can be specified vvith the combination o
34. tion Command U10 55H 31H 30H Parameter type Special parameter Refer to 7 3 1 Menu Display Auto OFF Parameter Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool down mode Emergency mode O O O X Communication Examples When specifying that the menu display is turned off automatically CTLR P 1 SP U10 SP 1 CR DLA 1 SP 0 CR When requesting the current menu display auto off setting if menu display does not turn off automatically CTLR 7 1 SP U10 CR DLA T SP SP O CR 30 12 17 Line Display U11 55H 31H 31H Definition Sets the line source area display after changing input terminals Command U17 55H 31H 31H Parameter type ONZ OFF Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool down mode Emergency mode O O O X Communication Examples When setting the line display to OFF CTLR Po SP U1 SP 0 CR DLA T SP 0 CR When requesting the current line display setting if the line display is set to ON CTLR 7 1 SP U11 CR DLA T SP SP 1 CR 31 12 18 Sleep Time U12 55H 31H 32H Definition Sets the sleep time Command U12 55H 31H 32H Parameter type Reply time 3seconds Conditions Operation mode Standby mode Power ON mode Cool dow