1. or RP EG EDI I EU EMI AS MEA 13 SECTION 9 BATTERY OPERATION cubre rS 14 10455 232 15 SEGTION 2 5 con ihe eae deese 17 TPU series Pallet Scale User s Guide SECTION 12 ERROR CODE 18 SECTION 13 TROUBLE SELF 19 SECTION 14 TROUBLE SHOOTING ise 9 2 erano D Men 20 lA i NO POWER 20 e d t Eae 21 T4 3 GANTT CHARGE THE BATTERY ees E EE S EN E LAE ns 22 D Mo Mic 23 5 UNS TABLE s toten p ERE ve e itia 23 SEG LION 15 tae eats 15 71 PARTS DRAWING Hes pde s es ca RE Ode Ede Rs aedeagal 24 15 2 NUMERIC AND ALPHABETIC CHARACTERS DISPLAY ON LCD 27 TPU series Pallet scale user s manual SECTION 1 INTRODUCTION The TPU series of pallet scale provides an accurate fast weighing solution for pallet truck There are 4 series scales within the range with 2 different fork size and optional built in min printer All the keypads are mechani
2. 3 2 Installation of TPU 6 be bonu 22221 aide b eei 3 2 2 Adjust release GEVICE a reu prede ioa e res ded adi aaa 3 SECTION 4 PALLET TRUCK OPERAT Biss ieee are e p ope vs 5 2 1 s hac t VI 5 4 27 Safety icy lek ope is cee 5 4 3 Maintenant ris cota ie n E ta candi ity aoa 6 RN 6 4 3 2 How to expel air from the pump 2 4 6 4 3 3 Daily check and 6 4594 ede setinns boca fif siad aeta 6 SECTION 5 KEY DESCRIPTIONS EA CHE HD CHR y SEGTION D DISPLAY oc csteticce vut a GR tnos 9 SECTION Z OPERATION ERE Sion EN TED crete ele enu vet 10 734 Zerong the spia so s en aee a o e cate 10 FECERIT omn 10 ToS JOB Setting ere T 4 Acc umulation Total osa eoe cen enr Avere exon 10 TD PLEU
3. The operator had better take on wear gloves and security shoes for labor protecting 6 Do not handle unstable or loosely stacked loads 7 Do not overload the truck 8 Do not subject to unbalanced load either side to side or along the length of the frame 9 The capacity of the truck TPU series Pallet Scale User s Guide assumes an evenly distributed load with the centre of the load being at the halfway point of the length of the forks 10 Make sure that length of the forks matches the length of the pallet 11 Lower the forks to lowest height when the truck is not being used 12 At other specific conditions or places the operator should be carefully to operate the pallet truck 4 3 MAINTENANCE 4 3 1 OIL Please check the oil level every six months The volume of oil is about 0 31 Use the hydraulic type oil according to temperature scale below Temperature Oil 5 C 45 C L HM68 Hydraulic oil equivalent to ISO VG68 15 C 5 C L HM46 Hydraulic oil equivalent to ISO VG46 4 3 2 HOW TO EXPEL AIR FROM THE PUMP UNIT The air may come into the hydraulic because of transportation or pump in upset position It can cause that forks do not elevate while pumping in the ASCENT position The air can be banished in the following way Let the control lever H106 to the LOWER position then move the handle H1501 up and down for several times 4 3 3 DAILY CHECK AND MAINTENANCE Daily check of the pallet truck
4. clockwise until the forks do not lower 4 If the forks do not descend when the control lever H106 is in the LOWER position turn the setting screw 140H clockwise until raising the control lever H106 lowers the forks Then check the NEUTRAL position as per item 2 and 3 5 If the forks do not lift while pumping in the ASCENT position turn the setting screw 140H counter clockwise until the forks elevate while pumping in the ASCENT position Then check the NEUTRAL and LOWER position as per item 2 3 and 4 4 TPU series Pallet scale user s manual SECTION 4 PALLET TRUCK OPERATE 4 1 CONTROL LEVER the control lever H106 which can be set in three positions LOWER to lower the forks NEUTRAL to move the load ASCENT to raise the forks After assembling the handle you can adjust the three positions 4 2 SAFETY NOTE For safe operation of the truck please read all warning signs and instructions here and on the truck before using this truck 1 Do not operate the pallet truck unless you are familiar with it and have been trained or authorized to do so 2 Do not operate the truck unless you have checked its condition Give special attention to the wheels the handle assembly the forks lift and the lower control 3 Do not use the truck on sloping ground 4 Never place any part of your body in the lifting mechanism or under the forks or load Do not carry passengers 5
5. keyboard Beeper run Check M B DU1 and around circuit Check U2 and LCD 21 TPU series Pallet Scale User s Guide 14 3 Can t charge the battery 22 START Battery bad battery voltage lt 5 5V Replace battery CHK AC adapter output 13V open Replace AC adapter CHK U8 pin2 output gt 7V CHK U8 and around circuit CHK D5 R2 and around circuit TPU series Pallet scale user s manual 14 4 Can t weigh CHK whether can show internal counts Add load on pan CHK counts raise Add load on pan CHK output between A D chip 1 and 2 signal change mV 14 5 Unstable START OK after warn Y N Dispel humidity Y Load cell and bracket touch something Solve touch problem CHK A D chip and around circuit 23 TPU series Pallet Scale User s Guide SECTIOIN 15 APENDIX 15 1 PARTS DRAWIN 150 H101 151 H102 H103 H104 H105 H112 H106 H107 H108 24 171 TPU series Pallet scale user s manual Parts List of Pump Assembly Part No Description Qty Part No Description Qty 101 Steel ball 1 136 Pressure regulating screw 1 102 Rod 1 137 O ring 1 103 Base 1 138 Screw 1 104 Steel roller 1 139H Crank link 1 105 Bushing 1 140H Setting screw 1 106 Pin 1 141 Nut 1 107 Shaft 2 142 Parallel pin 1 108 Retaining ring 1 143 Retainin
6. 0H Header follow weighing unit If weighing unit g header3 21H If weighing unit oz header3 23H Weight1 weight6 weighing data Tare1 tare6 tare value Terminator1 Terminator2 OAH Header0 01H oo ou Header1 follow weight or When weight header1 when weight header Weight1 weight7 weight data include decimal point Unit1 unit2 weight unit Status when stable status 0 when unstable status 1 Terminator1 ODH Terminator2 OAH 16 TPU series Pallet scale user s manual SECTION 11 CALIBRATION Press the TARE key at the check weighing mode display shows Pn enter password 000 into Parameter the display show FU CAL press key display UnL ofid then press the key to enter the display shows UnLoAd Remove any weight from the platform After stable indicator on press the key Then the display will show the last calibration weight used If this is correct you can continue by pressing the TARE key If it is not correct use the REPORT key to move and press G N key to change the calibration weight value When will be correct press the TARE key Then display will show LoHd Place the calibration weight on the scale After stable press the key Then the calibration has completed 17 TPU se
7. PALLET TRUCK SCALE TECHNICAL MANUAL FScale TPU series Pallet Scale User s Guide Manufacturer TScale Electronics Mfg Kunshan Co Lid Model TPR Report No GS109121102608 EMC Directive 2004 108 EC Applicable Standards EN 55022 2006 A1 2007 EN 61000 3 3 1995 A1 2001 A2 2005 EN 55024 1998 A1 2001 A2 2003 Declaration of Conformity Note The declaration is only valid if the non automatic weighing instrument was verified by the manufacturer or with a certificate of conformity issued by a notified body Copyright by TScale Electronics Mfg Kunshan Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Taiwan scale T Scale reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication was to the best of our knowledge timely complete and accurate when issued However we are not responsible for misimpressions which may result form the reading of this material sales taiwanscale com www taiwanscale com TPU series Pallet scale user s manual Table of Contents SECTION 1 INTRODUGTION ca pip aed 1 SECTIONS 2 SPEGIEIGATIONS vtae e RE un a e 2 SECTION S INSTALEATION e ctis ted ter es eo reU e CR 3 S aeneis
8. an set the tare value 7 6 Print Report Printer use internal EPM250 printer Print format can divide customer list product list and all report list print Press M key print currently weight report 7 6 1 Printer 1 format Print Select Printer 1 format then press key print all weight report of product and customer 11 TPU series Pallet Scale User s Guide Print format is 2010 09 15 11 30 01 99 99 37 0 TARE 20 0 7 6 2 printer 2 format Print Select printer 2 in the parameter then press M key print all accumulation weight report Print format is 2010 09 15 11 05 PLU 00 PRODUCT 00 CUST 00 No NET TARE TOTAL 01 57 0 0 0 57 0 02 57 0 0 0 114 0 7 6 3 Print All Report Press REPORT key print all weighing report Print format is DATA 2000 00 00 TIME 00 00 ALL RECORD PRODUCT CUST NET 99 99 49 0 2010 09 10 14 09 99 99 49 0 2010 09 10 14 09 88 88 49 5 2010 09 10 14 10 12 TPU series Pallet scale user s manual SECTION 8 PARAMETERS The scale has 6 parameters that can be set by the user plus a method of entering the calibration section Press the TARE key at the check weighing mode The display will show P in enter the password 000 will display FO CAL Pressing the REPORT key will cycle through the next function Press the key wi
9. cal switches and the displays are large easy to read liquid crystal type displays LCD The LCD s are supplied with a backlight All units include automatic zero tracking weighing unit change pretare gross net change PLU memory that allows the individual weights to be stored and print report TPU series Pallet Scale User s Guide SECTION 2 SPECIFICATIONS Model TPU Max Lifting weight 2000kg Min Fork Height 85mm Max fork height 200mm Fork length 1135mm Fork overall width 555mm 688mm Individual fork width 180mm Capacity 1000kg 2000kg Division 0 5kg 1kg External resolution 1 2 000 Internal resolution 1 600 000 Stabilisation Time 1 Seconds typical Operating Temperature 0 C 40 C 32 F 104 F Power supply External power switch 12V 500mA built in rechargeable battery lead acid 6V 10Ah Calibration Automatic External Display 6 digits LCD digital display with 24mm high digits LED backlight Interface RS 232 Output Optional Load cells 4 load cells 2 TPU series Pallet scale user s manual SECTION 3 INSTALLATION 3 1 GENERAL INSTALLATION Avoid extremes of temperature Do not place in direct sunlight or near air conditioning vents Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scales in water Keep the scales clean Do not stack material on t
10. can limit wear as much as possible Give special attention to the wheels 127 F116 or F117 the axles F114 F118 F121 F122 the handle H101 the forks F110 and lift and lower control The forks should be unloaded and lowered in the lowest position when the job is over 4 3 4 LUBRICATION Use motor oil or grease to lubricate all moveable parts 6 TPU series Pallet scale user s manual SECTION 5 KEY DESCRIPTIONS Zero Set the zero point for all subsequent weighing The display shows zero A secondary function is ESC of Enter key when setting parameters or other functions Tare Tare the scale Stores the current weight in memory as a tare value subtracts the tare value from the weight and shows the results This is the net weight Entering a value using the keypad will store that value as the tare value A secondary function ise of incrementing the active digit when setting a value for parameters or other functions G N Press the key the scale can to select gross weight or net weight after you tare a weight M Press this key for a short time to accumulation and take print out press this key for a long time to clear all record CE Press this key to select the weight unit Move the active digit left wnen setting values for other functions PLU Press this key for short time to take the PLU value Press this key for long time to set the PLU value REPORT Press this key short time to show the latest rep
11. ero the scale if small amounts of weight are shown when the platform is empty 7 2 Taring Zero the scale by pressing the ZERO key if necessary The zero indication will be on Place a container on the platform a value for its weight will be displayed Press the TARE key to tare the scale The weight that was displayed is stored as the tare value and that value is subtracted from the display leaving zero on the display The TARE indicator will be on As product is added only the weight of the product will be shown The scale could be tared a second time if another type of product was to be added to the first one Again only the weight that is added after taring will be displayed When the container is removed a negative value will be shown If the scale was tared just before removing the container this value is the gross weight of the container plus all product that was removed The zero indication will also be on because the platform is back to the same condition it was when the ZERO key was last pressed 7 3 USB Setting Press REPORT key for a long time into USB operation mode until display U1 LOAD PLU Press REPORT key to select NO Send way Send data U1 LOAD PLU U2 SAVE PLU U3 SAVE REPORD 7 4 Accumulated Total 7 4 1 Accumulate note Every time before do accumulate operate please empty the fork ZERO indicator on and stable STABLE indicator on Accumulate operate
12. g cover 1 109 Axle 1 144 Spring cover 1 110 Screw 1 145 Spring 1 111 Washer 1 146 Pump rod 1 112 Spring 1 147 Dust proof ring 1 113 Pressure rod 1 148 Pump cylinder 1 114 Steel ball 1 149 Seal ring 1 115 Pressure valve body 1 150 Nylon bushing 1 116 Split ring 1 151 Red copper washer 1 117 O ring 2 152 Retaining ring 1 118 Washer 2 153 Rhombus plate 1 119 Steel needle 1 154 Pin 2 120 Bushing 2 155 Dowel pin 2 121 Pin 2 156 Dust proof ring 1 122H Pump body 1 157 O ring 1 123 Dust cover 1 157 1 O ring 1 124 Bearing 1 158H O ring 1 125 Steering wheel axle 1 159H Cylinder 1 126 Bearing 4 160H Seal ring 1 127A Steering wheel Nylon 2 161H O ring 1 127B Steering wheel Polyurethane 2 162H Filler plug 1 1276 Steering wheel Poly Nylon 2 163H Reservoir cover 1 1270 Steering wheel Rubber 2 164H Screw 2 128 Retaining ring 2 165H Reservoir 1 129 Steel ball 1 166 Retainer 3 130 Discharge valve body 1 167 Retainer 1 131 Spring 1 168 Retainer 1 132 O ring 1 169 O ring 1 133 Discharge valve shaft 1 170 Retainer 1 134 Valve taper core 1 171 Bearing Cover 2 135 Spring 1 Parts List of Handle Part No Description Qty Part No Description Qty H101 Handle 1 H107 Rod and chain 1 H102 Spring pin 1 H108 Rubber cushion 1 H103 Spring leaf 1 H109 Screw 3 H104 Spring pin 2 H110 Spring washer 3 H105 Spring pin 1 111 Nylon roller 1 H106 Control lever 1 112 Spring pin 1 25 TPR series Pallet scale User
13. he scale will be set date and time The number increments every time a new value is stored in memory GW for gross weight NT for net weight and a unit of weight When parts counted the weight unit weight and count will be printed Date The scale hasn t printed ime 00 00 The scale will be set time Gross wt 0 149KG GW for gross weight NT for net weight and a unit of weight Unit wt 7 4257G The average piece weight computed by the scale Quantity 20PCS number of parts counted A line of stars is shown Includes 1 line feed 3 Times of the accumulation memory 0 447KG Weight of the accumulation memory kkkkkkkkkkkkkkk 10 3 continuously output protocol con1 weighing mode 15 TPU series Pallet Scale User s Guide o enu HEADER1 HEADER2 WEIGHT DATA unr TERMINATOR coni counting QTY QTY UNIT HEADER US UNSTABLE HEADER2 NT NET GS GROSS 2 Header0 02H Header1 follow decimal point Decimal point 0 header1 22H Decimal point 1 header1 23H Decimal point 2 header1 24H Decimal point 3 header1 25H Decimal point 4 header1 26H Header2 follow weigh status default value 20H If in net mode tare value not 0 header2 header2 01H If gross weight header2 header2 02H If overload or gross weight header2 header2 04H If unstable header2 header2 08H If weighing unit kg header2 header2 1
14. he scales when they are not in use Please ascent the pallet before read weight data Please don t read data when pallet truck moving Please charge battery to full before use see detail in SECTION 9 3 2 INSTALLATION OF TPU SERIES 3 2 1 Install handle The handle is packing separate from pallet truck 1 Loosen the setting screw 140H on the crank link 139H 2 Remove three screws H109 and three spring washers H110 from the base 103 3 Place the handle H101 on the base 103 please note Feed the rod and chain H107 through the centre of the base 103 and axle 109 L2 4 Insert three screws H109 with spring washers H110 into the base 103 Then tighten them securely 5 Raise the crank link 139H and put the pin on rod and chain H107 3 TPU series Pallet Scale User s Guide into the groove of crank link 139H 3 2 2 To adjust release device On the handle of the pallet truck you will find the control lever H106 which can be set in three positions 1 First tighten the setting screw 140H on the crank link 139H until the LOWER position function works 2 If the forks elevate while pumping in the NEUTRAL position turn the setting screw 140H clockwise until pumping the handle does not raise the forks and the NEUTRAL position functions correctly 3 If the forks descend while pumping in the NEUTRAL position turn the setting screw 140H counter
15. ll back to late function FUNCTION MENU SETTINGS FUNCTION DESCRIPTION FO CAL Calibration press TARE key display unload place the pan when the stable indicator display press the TARE key will display the weight value press REPORT key to turn next and press the number keys enter the value put the same value weights on the pan until the stable indicator display press the TARE key to finish FI ES Set the division value Press the REPORT key to select increase 1 2 5 10 20 50 100 press the TARE key to confirm U nb Sets the displayed unit Kg Ib you can press TARE key to set ON or OFF press ZERO key to confirm dESL Setting weight decimal Press the REPORT key to select decimal 0 0 0 0 00 0 000 press the TARE key to confirm CAP Set the capacity press REPORT to turn next value and press the number key enter the value press TARE key to confirm FS Ero Press TARE key to set the auto zero value Press TARE key to set the rezero value inPS Press key to display internal count value FB PrE Set the Print format press REPORT key to select Pr int P and Pr mt Oru Set the gravity F bd Set the Baud rate press REPORT key to select 600 1300 2400 4800 9600 13 TPU series Pallet Scale User s Guide SECTION 9 BATTERY OPERATION The weighing indicator can be operated fro
16. load cell Shipping screw not removed if applicable Look for obstruction under pan Cannot use Full shipping screws and verify pan Capacity Electronic problem on A D T 2 set incorrectly Check the weighing units used Load Cell or mechanics Damaged Look for obstruction under Overload stops hitting too soon shipping screws and verify pan Not Linear Load cell or mechanics damaged installation A D damaged If linearity can be set by the user it will be described in the user manual Off Center Adjust mechanics Look for obstruction under pan Loading error Overload Stops not correct shipping screws and verify pan Load Cell damaged installation Mains voltage not present or too Verify the batteries are rechargeable Battery will not low types charge Charging circuit failure Check power supply voltage is Battery Failure correct 19 TPU series Pallet Scale User s Guide SECTIOIN 14 TROUBLE SHOOTING 14 1 No power CHK power switch 2 G Replace power switch o Battery voltaae gt 6V N Charging the battery immediately or replace the battery N CHK U4 and around circuit CHK 2 and around circuit N Y N U4 pin 1 Output 5V CHK ST around circuit CHK U1 and around circuit 20 TPU series Pallet scale user s manual 14 2 No display START CHK LCD break Replace LCD Press
17. m the battery if desired The battery life is approximately 35 hours When the battery needs charging a symbol on the weight display will turn on The battery should be charged when the symbol is on The scale will still operate for about 10 hours after which it will automatically switch off to protect the battery To charge the battery simply plug into the mains power The scale does not need to be turned on The battery should be charged for 12 hours for full capacity In the LCD display has a battery indication to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged When turn on the indication if the battery indication is full then the battery has a full charge f it is half then the battery is nearly discharged and empty indicates the battery should be charged As the battery is used it may fail to hold a full charge If the battery life becomes unacceptable then contact your distributor 14 TPU series Pallet scale user s manual SECTION 10 RS 232 OUTPUT The RW Series of scales can be ordered with an optional RS 232 output 10 1 Basic information Specifications RS 232 output of weighing data ASCII code 8 data bits No Parity Baud rate from 600bps to 9600bps 10 2 normal print out Data Format for normal weighing operations parts counting or recalling of totals from memory will all be different Examples follow Normal Output Date and Time T
18. odule or scale Display blank after turn on Pan not installed test Unstable weight Check the pans are installed correctly Error message Load cell damaged Try turning the scale on again Display is Mechanics damaged locked OL or Maximum capacity exceeded Check the pans are installed correctly appears on Load Cell or mechanics damaged Try ining ie scale on again display Power supply faulty Weight on scale below permissible or NULL remavad the pans are installed correctly displayed Pan support not seated properly TY Power supply faulty ry turning the scale on again Load Cell or mechanics damaged Drafts or air currents Se animal Verify the scale is in a acceptable Display is weighing location and on a good table unstable Vibrations through table power supply is correct for Temperature changed dramatically espas Power supply faulty Calibration error Recalibrate Calibrate again paying special Linearity error set Linearity attention to the mass used the Unit calibrated with inaccurate stability of the scale and the weighing Weight value weight units required incorrect Balance not level If linearity can be set by the user it will Obstruction between sample and be described in the user manual cover Check pan is installed correctly Wrong unit of weight displayed Verify installation is acceptable Over load Stops hitting pan support or hitting bottom of
19. only available current weight more than 20d min capacity 10 TPU series Pallet scale user s manual 7 4 2 Accumulate operate After weighing a pallet with goods display show weight data after STABLE indicator on press M key the weight displayed will be stored in memory The display will show l and then the total in memory for 2 seconds before returning to normal If the optional min printer is installed the weight will be output to a printer Remove the weight allowing the scale to return to zero and put a second weight on Press the M key the display will show ALC and then the new total Continue until all weights have been added The scale can do accumulation operate 99 times at most 7 4 4 Memory clear To clear the accumulate data in memory just press M key a long time to clear accumulate data 7 5 PLU Setting The scale has two PLU modes direct PLU and indirect PLU 7 5 1 Direct PLU operation Press number key for a long time to memory the PLU content Press number key for a short time to display PLU 7 5 2 Indirect PLU operation Press key for a long time to set PLU content Press PLU key then press number key to display indirect PLU 7 5 3 Memory PLU operation Press PRODUCT key to set product number Press PLU key into set the PLU number then press TARE key for a long time into pretare setting this setting c
20. ort and total Press this key long time to enter the USB operation menu 1 9 The number key press these keys to enter the number Press this key short time to enter a point press this key long time into the setting of date and time Product or E Press this key short time into the product number setting Press this key long time 27 TPU series Pallet Scale User s Guide into backlight setting Cust or i Press this key short time into the customer number setting Press this key long time into backlight setting ON OFF Turn on or off the power TPU series Pallet scale user s manual SECTION 6 DISPLAYS The LCD display will show a value and a unit to the right of the digits In addition there are labels for TARE GROSS weight Zero and for Low battery Percentage weighing Battery low Parts counting iiBBBBBE Weighing unit Check weighing TPU series Pallet Scale User s Guide SECTION 7 OPERATION 7 1 Zeroing the Display You can press the ZERO key at any time to set the zero point from which all other weighing and counting is measured within 4 of power up zero This will usually only be necessary when the platform is empty When the zero point is obtained the display will show the indicator for zero The scale has an automatic rezeroing function to account for minor drifting or accumulation of material on the platform However you may need to press the ZERO key to rez
21. ries Pallet Scale User s Guide SECTION 12 ERROR CODES ERROR CODES DESCRIPTION RESOLUTION Over range Remove weight from the scale If the problem persists contact your dealer or Taiwan scale for assistance Err Date Setting Error Enter date using correct format and reasonable values Format yy mm dd Err g Time Setting Error Enter time using correct format and reasonable values Format hh mm ss Err Zero Setting Error The scale was outside the normal zero setting range either when it was turned on or when the ZERO key was pressed Remove weight from the scale and try again Use the TARE key to set the display to zero value If the problem persists contact your dealer or Taiwan scale for assistance Err 6 A D out of range The values from the A D converter are outside the normal range Remove weight from the scale if overloaded make sure the pan is attached Indicates the load cell or the electronics may be faulty If the problem persist contact your dealer 18 TPU series Pallet scale user s manual SECTION 13 TROUBLE SELF CHECKING Problem Possible cause Common solutions Mains power is turned off Check power is going to the scale and Power supply not plugged in switch is on NE s oar Power supply faulty Verify the voltage going to the scale Internal battery not charged matches the power supply labels on Display turned off the power m
22. s Guide Parts List of Frame F112 F118 F112 No Description Q ty No Description Q ty F301 Signal wire 1 F101 Torsion tube assembly 1 F304 Screw 8 F102 Bushing 4 F317 Wire clip 2 F103 Hexagon socket screw 1 F318 Screw 4 F104 Spring pin 1 F319 Fix screw 4 F105 Torsion tube shaft 1 F320S Cover plate assembly 555mm 1 F112 Spring pin 8 4 F320L Cover plate assembly 690mm 1 F113 H link 2 F321 Convex spherical washer 4 F114 Load roller axle 4 F322 Concave spherical washer 4 F115 Bearing 8 4 F323 Nut 4 F116B Poly load roller tandem type 4 F324 Set screw 4 F117B Poly load roller single type 2 F325 Bolt 8 F118 Axle 2 F326A Load cell 4 F119 Roller 2 F327S Frame 555mm 1 F120 Wheel frame 2 F327L Frame 690mm 1 F121 H link axle 2 F328 Pull rod 2 F122 Pull rod axle 2 F123 Nut 2 F124 Spring washer 2 F126 Eccentric pin 2 Note Quantity for tandem roller is 8 for single roller is 4 26 TPU series Pallet scale user s manual 15 2 NUMERIC AND ALPHABETIC CHARACTERS DISPLAYED ON LCD 0 1 2 3 4 5 6 7 8 9 o e j 5 3l B 9 C D E F G H J L d F G H K L M N O E Q R T F L n P 5 r E U V W X Y Z u v e 27