User Manual & Information Guide

image

Contents

1. 460 Enterprise St San Marcos California 92078 USA Tel 760 744 6561 Fax 760 744 0054 solutions AincA com www AincA com
2. High Level Disinfection 2 Clean 2 Parts may be cleaned with Gluteraldehyde solution per an alcohol wipe a disinfectant manufacturers recommendation wipe or by sponging with a clean damp soft cloth and dried Sterrad gas plasma hydrogen N A Any monitor which becomes peroxide per manufacturers contaminated with patient recommendation materials must be properly disposed of Disinfection Sterilization DO NOT AUTOCLAVE The AincA VideoStylet Troubleshooting Stylet s surface is damaged Damaged during use Replace stylet No video image in situation using Damaged by electrical shock from Do not use in conjunction with defibrillator defibrillator to patient defibrillator use Video image not clear eContaminants on the stylet lens Use 75 alcohol sponge to clean surface the stylet lens eLCD monitor was dropped eReplace LCD monitor eStylet was damaged eReplace stylet eStylet was damaged eReplace stylet the LCD monitor and stylet charge usable life NG M Anesthesia Associates Inc AincA e Visit us on the web at www AincA com Page 5 Warnings e Do not use the video stylet if any parts are damaged e Do not use the video stylet during defibrillation e Video stylet is not to be used with highly flammable anesthetic gasses e Do not allow the stylet tip to protrude past the distal end of ET tube It may damage patient airway e Video stylet is neither MRI safe nor MRI compatible e Inspect stylet f
3. Rated voltage Degree of protection Diameter Illumination method Tip temperature in ambient room Camera type Field of view camera Operating environment temperature Operating environment relative humidity Storage environment temperature Storage relative humidity IP protection classification system Ref ET tube ID 6 0 6 5 length 32 0cm 12 6 Ref ET tube ID 7 0 7 5 length 33 5cm 13 2 Ref ET tube ID 8 0 8 5 length 34 5cm 13 6 Ref Veterinary tube length 45 7cm 18 0 lt 28g lt loz 12 months or 100 uses whichever comes first 3 5 to 4 2 VDC BF type applied part 5 8mm max 2 LEDs white color lt 430C lt 1090F CMOS 540 10 40 C 50 1049F 30 85 10 40 C 50 1049F 30 85 IP67 NG Anesthesia Associates Inc AincA e Visit us on the web at www AincA com Page 7 ANA VideoStylet Difficult Visualization Made Easy Component amp Kit Information Monitor Charger Stylet Video m 32 0CM 12 6 VideoStylet A AincA VideoStylet Kit A P N 00 675 A 1 P N 00 675 A VideoStylet B AincA VideoStylet Kit B P N 00 675 B 1 P N 00 675 B LCD Monitor with Charger P N 00 675 LCD VideoStylet C AincA VideoStylet Kit C P N 00 675 C 1 P N 00 675 C VideoStylet V AincA VideoStylet Kit V P N 00 675 V 1 P N 00 675 V Change your intubation perspective view through the tip of the ET Tube Anesthesia Associates Inc
4. ANA VideoStylet Difficult Visualization Made Easy User Manual amp Information Guide NG M Anesthesia Associates Inc AincA Visit us on the web at www AincA com 00 675 IFU Rev Table of Contents PRODO U cg GUE eer ee nee er EE erm eres ee eee eee Page 03 1B GBF e okey age VDO srie rere een Cerin treet en eee rer eee eto eee EEE Page 03 S 5 gl G0 EE S ee re E AEE N eer eee eee ee ree een eer Page 04 oiia 06 oles 8 ogy Os caer eee A eer E E E ae Page 04 Cleaning Disintection es deo Cer ell NAc 0 0 0 Geen meeee ener are one ter ee peer etter etre errant a nrer ee mr rene eer ere Page 05 MAQUI SO OU IN oee ea EE EEEE OAE EEA EAN EEE E EA E N EE Page 05 bae EE 6 kc P E A E E A E E ee ee E Page 06 IY ALU T E E A A T E Page 06 L EE E ne ne E E E A S A E E err er eee Page 07 Indication for Use The AincA VideoStylet is intended for use as an Intubation device to examine and visualize a patients upper airway and aid in the placement of a tracheal tube Federal USA law restricts these devices for sale only by or on the order of a physician The AincA VidoeStylet should be used only by individuals who have been trained and authorized by a physician or by health care providers who have been trained and authorized by the institution providing patient care Anesthesia Associates Inc AincA 460 Enterprise Street San Marcos CA 92078 Tel 760 744 6561 Fax 760 744 0054 Solutions AincA com Wwww AincA com
5. For additional contact information please visit our website www AincA com Information in this User Manual and Information Guide may change at any time and without notice For the most up to date version please see online at www AincA com For warranty questions or information please call Customer Service at 760 744 6561 Part Numbers 00 675 A 00 675 B 00 675 C 00 675 V NG Anesthesia Associates Inc AincA e Visit us on the web at www AincA com Page 2 Prior to Use Guide Charging 1 Plug the charging unit into an appropriate power outlet 2 Align the arrow on the charging unit connector and the black arrow on the base of the LCD monitor 3 Gently push the charging connector into the port in the LCD monitor It will mate with ease when correctly aligned DO NOT FORCE CONNECTION 4 When the LCD monitor is charging the charge indicator light in the upper right hand corner will be red When it turns green the charging is complete and the monitor is ready to use 5 When the LCD monitor has completed charging gently separate the plug from the monitor LCD Monitor Symbols Table 1 VYEllony AIO ae 7 Stylet past 100 uses OPOP Charge Indicator Cause Uses Red Charging Action Recharge Unit Replace Stylet Replace Monitor Gre Fully Charged Only displays while charging VideoStylet NG M Anesthesia Associates Inc AincA e Visit us on the web at www AincA com Page 3 User Gui
6. ctly mounted on an operational AincA VideoStylet See User Guide S 1 Look directly into the patients mouth and with the Laryngoscope in the left hand introduce the AincA VideoStylet camera first into the oral pharynx 2 With the AincA VideoStylet inserted look to the monitor to identify the epiglottis then gently manipulate the laryngoscope to obtain the best glottic view 3 Carefully guide the distal tip of the AincA VideoStylet into position near the tip of the laryngoscope Avoid the tissues and the soft palate 4 Look to the monitor to complete the intubation gently rotate or angle the ET tube to redirect and adjust as needed 5 Gently disconnect the ET tube from the video stylet white block and carefully slide the stylet out from the ET tube After use separate the monitor from the stylet to turn the system OFF NG Anesthesia Associates Inc AincA e Visit us on the web at www AincA com Page 4 Cleaning Disinfection amp Sterilization The AincA VideoStylet System LCD Monitor Clean 1 Parts may be washed in warm soapy water composed of mild detergents or a natural liquid soap and carefully scrubbed with Cleaning soft brush rinsed and dried Clean 2 Parts may be cleaned with Clean 2 Parts may be cleaned with an alcohol wipe a disinfectant an alcohol wipe a disinfectant wipe or by sponging witha clean wipe or by sponging with a clean damp soft cloth and dried damp soft cloth and dried
7. de Before use inspect the LCD monitor and stylet for obvious damage or wear that will prohibit the use of the AincA VideoStylet If any exist replace the product 1 Align the black arrow on the white connecting block of the stylet and the black arrow on the base of the LCD monitor 2 Gently push the stylet s gold connector into the base of the LCD monitor Upon connection the LCD monitor will turn ON and a camera image will appear If no monitor symbols are illuminated above the LCD then the unit is ready for normal use If monitor symbols become illuminated refer to Table 1 3 Appropriately lubricate the stylet prior to insertion in the ET tube Keep camera lens area clean and clear 4 Load the ET tube onto the stylet and mate the ET tubes adapter to the white stop on the stylet block 5 WARNING Adjust the position of the ET tube to ensure that the end of the STYLET is 0 5cm 0 2 INSIDE the ET tube tip Do NOT let the end of the stylet protrude past the ET tube it may damage the patients airway 6 Gently curve the stylet with ET tube on it into an appropriate shape for the intubation Note Use of large radius curves will extend the life of your malleable stylet 7 Verify that a clear image from the camera is displayed on the monitor Your AincA VideoStylet is now ready to use Suggestions for Use lt Utilization with or without a laryngoscope is at the user s discretion gm CAYLA With the ET tube corre
8. ge due to or as the result of service or modification by anyone other than the factory e Equipment exposure in excess of 40 C 1049F or monitor exposure to liquids and or contaminates e Product usage not in accordance with the instructions contained in this User s Manual NG Anesthesia Associates Inc AincA e Visit us on the web at www AincA com Page 6 Specifications Product LCD Monitor w Charger Part Number 00 675 LCD Weight 76g 2 702 Warranty 12 month or 1 000 uses whichever comes first Rated voltage 3 5 4 2 VDC Form of protection Internally powered device Degree of protection BF type applied part Width Height Thickness Response time Display type Brightness control Contrast control Battery type Recharge time Useful operation full charge Charge cycles Charge Video signal standard Operation environment temperature Operating environment relative humidity 7 3cm 2 87 in 5 7cm 2 24 in 2 3cm 0 91 in 15ms 2 4 color TFT LCD Auto Auto 4 2V 800mAh Li ion battery 2 hours 2 hours Aprox 300 times Input 120VAC 60Hz Output 5 VDC 1 0 A NTSC 10 40 C 50 104 F 30 85 Storage environment temperature 10 40 C 50 1040F Storage relative humidity 30 85 IP protection classification system IP 50 Product Stylet Video Part number See Below Model A P N 00 675 A 1 Model B P N 00 675 B 1 Model C P N 00 675 C 1 Model V P N 00 675 V 1 Weight Warranty
9. or damage and unusual wear Discard any damaged or obviously unserviceable parts e Do not Autoclave the AincA VideoStylet Precautions e US federal law restricts these devices for sale only by or on the order of a physician e Do not fold or tightly bend the sylet as it will cause the stylet to break e Keep the LCD monitor dry e To minimize contamination always wear gloves during preparation and intubation and avoid contact with any contaminated surfaces e Make sure that the LCD monitor is fully charged before use e Disconnect the LCD monitor from any main power supply before cleaning e Clean the LCD monitor after each use e Have spare parts ready and prepared for immediate use e Do not drop monitor or stylet Do not use a knife or other sharp instrument near the stylet e Remove secretions from the airway before and during the procedure Appropriate suction devices or other standard procedures can be used for this purpose Warranty For warranty details refer to the product warranty section in our catalog Available online www AincA com Anesthesia Associates Inc warrants the AincA VideoStylet system against defects in material and workmanship for a period of twelve 12 months from the date of shipment from Anesthesia Associates Inc or 100 uses stylet or 1 000 uses monitor whichever comes first Warranty does not cover e Damage due to dropping or mishandling any part or tightly bending the stylet e Dama