KS-258 User`s Manual
Contents
1. lt 5 gt How To Set Alarm Volume Loudest volume by default Directive Instruction 21 Lowest 22 Middle 23 Louder 24 Loudest Instruction After entering directive main unit will make alarm sound with the volume as you set then press A to confirm and it will make four short Di sound which means the setting is successful lt 6 gt How To Set Inner Siren Duration 30 Minutes by default 25 DD Instruction DD is the inner siren duration which ranges from 00 to 99 minutes and it should be 2 bits When main unit occurring alarm it will make alarm sound till the alarm duration arrives then main unit will close alarm sound automatically if there are wireless siren then it will close alarm sound of wireless external siren at the same time Note If the alarm duration is set to be 00 which means the main unit is in mute alarm mode if you don t want it to be mute then you only need to enter alarm duration and then it will cancel mute function lt 7 gt How To Set Delay Arm Time Leaving Time 00 second by default 26 DD Instruction DD is delay arm time and it ranges from 00 to 99 seconds and it should be 2 bits Delay arm time is only valid to away home mode When you press Away Home button on remote controller main unit will enter delay arm time immediately and then the main unit will make a short Di sound every one second and you should leave the defense area d
2. 15 8 5How To Control Remotely 16 9 Technical Parameter 17 10 Standard Packing List 18 11 Optional Packing List 18 12 Frequently Ask Questions 18 13 Program Directives 19 Common User s Program Directives 19 Manager s Program Directives 21 Operate Directives When Receipt Of Alarm Telephone 22 Directives Of Remote Operation 22 Recover To Ex factory Default State 22 Summary This system adopts microprocessor as control core and it can work with wireless remote controllers and all kinds of wireless PIR detectors It characteristics of many functions such as anti theft anti rob anti fire emergency ask for help and so on It reports alarm message to users and network manage center by dialing telephone number preset when alarming It also can be armed disarmed remotely And wireless siren can be linkaged to make alarm sound when alarming We believe that humanly design and reasonable price will satisfied
3. Instruction After entering 03 main unit will make a short Di sound and then you can enter 8 bit numbers ranges from 0 to 6 and press to confirm then it will make four short Di sound which means the setting is successful Application 1 When connecting with monitor center if the type of some zone has been set monitor center can see the alarm type when alarm occurs in this zone such as anti theft fire alarm gas alarm and so on 2 When there is some malfunction occurs in some zone set to be bypass zone is recommended because the main unit will not receive any information from this zone And then you can set it to be other types after precluding malfunctions Suggestion Set the unused zones to be Bypass Zone lt 4 gt How To Modify User code 000000 by default 09 BBBBBB BBBBBB BBBBBB is 6 bits new code and it should be any number ranges from 0 to 9 Instruction After entering 09 you will hear a short Di sound then you can enter 6 bits new code and press a to confirm after hearing a short Di sound enter 6 bits new code and a again it will make four short Di sound which means the setting is successful After modifying the code the old code is invalid automatically and you should enter setting state by entering new code next time Note you should keep the code in mind if you forget it please recover user s code according to 6 1 chapters
4. Battery should be well connected 2 Correctly connect the battery 3 Change the battery The emit distance of remote controller door sensor become shorter The battery power lower Change the battery and pull antenna out It can t be controlled remotely 1 A model hasn t this function 2 The anti theft function of telephone is opened Make sure that the main unit is B model 2 Close anti theft function of telephone 13 Program Directives Common User s Program Directives 000 000 by default O Exit from programming state 01 Zone Number At Home Zone List 12345678 by default 02 Zone Number Away Home Zone List 12345678 by default O34XXXXXXXX Zone Attribute List 11111111 by default O44XXXXXXXX Telephone Attribute 11111111 by default q 05 Accounts Set CONTACT ID Accounts 0000 by default 09 New Code New Code Modify User s Code 000 000 by default 11 Telephone Number Set the first group of telephone number 12 Telephone Number Set the second group of telephone number Deduce by analogy 18 Set the eighth group of telephone number 11 Delete the first group of telephone number 12 Delete the second group of telephone number Deduce by analogy 18 Delete the eighth group of telephone number 19 Delete all telephone number 21 Alarm sound is
5. 13 Delete the third detector in the first zone Deduce by analogy 81 Delete the first detector in the eighth zone 82 Delete the second detector in the eighth zone 83 Delete the third detector in the eighth zone 91 Learn the first remote controller 92 Learn the second remote controller Deduce by analogy 98 Learn the eighth remote controller 91 Delete the first remote controller 92 Delete the second remote controller Deduce by analogy O8 Delete the eighth remote controller 19 Display zones which code of detector has been learned 99 Display zones which code of remote controller has been learned 03 Delete all remote controllers 04 Delete all detectors Ph Operate Directives When Receipt Of Alarm Telephone O Exit from telephone answering state 1 Arm immediately Arm in away home mode 2 Disarm immediately 3 Alarm on the spot 4 Monitor Directives Of Operation Remotely 0 Exit from operation remotely 1 Arm immediately Arm in away home mode 2 Disarm immediately 3 Alarm on the spot Ex factory Default State User s Code 000 000 At Home Zone List All zones Away Home Zone List All zones Zone Attribute 111111 Telephone Type 111111 Monitor Accounts 00 00 Alarm Telephone No Alarm Volume The loudest Alarm Duration 30 Minutes Delay Arm Time 0 Second Delay Alarm Time 0 Second Ringin
6. Controller 12 lt 6 gt How To Delete Remote Controller 12 lt 7 gt How To Display Registered Remote Controller 12 7 System Installation 13 7 1Testing Before Installation 13 7 2Installation Requirements 13 7 3Installation And Debugging Of Main Unit And Accessories 13 lt 1 gt Main Unit 13 lt 2 gt Wireless Remote Controller 13 lt 3 gt Wireless Door Sensor 14 lt 4 gt PIR Detector 14 lt 5 gt Smoke Detector Gas Detector 14 7 4Testing After Installation 14 8 User s Operation 14 8 1All Indicate Sound Of Main Unit 14 8 2Indications When Power On Main Unit 15 8 3 How To Alarm 15 8 4How To Operate When Receipt Of Alarm Telephone
7. Siren 7 5 4Telephone Setting 8 lt 1 gt How To Set Telephone Numbers 8 lt 2 gt How To Delete Telephone Numbers 8 lt 3 gt How To Set Telephone Attribute 9 lt 4 gt How To Set Cycle Times Of Dialing 9 lt 5 gt How To Open Close Telephone Line Cut Detect Function 9 lt 6 gt How To Set Ringing Times Of Operation Remotely 9 5 5 Alarm Monitor Center Setting 9 lt 1 gt How To Enter Networking Accounts 10 lt 2 gt How To Set Report To Monitor Center When Armed Disarmed 10 lt 3 gt How To Set Report To Monitor Center When Power Lower 10 6 Manager s Setting 10 lt 1 gt How To Recover User s Code 10 lt 2 gt How To Register Detector 10 lt 3 gt How To Delete Detector 11 lt 4 gt How To Display Registered Zones 11 lt 5 gt How To Register Remote
8. check its working performance carefully when it reaches to sucha temperature and then adjust it 5 There is no power or the battery is used out or damaged 6 The alarm trumpet is installed at the other side of the door closed so it may not be able to warn or wake the sleeper 7 There is something wrong with telephone line which transmits alarm signals to the alarm center or the lines are busy so that it cannot transmit signals in time 8 When someone intrudes the common reason why the system cannot alarm is that the system doesn t get normal maintenance Like other electrical equipments the electronic elements of this equipment also may be damaged Therefore user should check the system periodically everyday 9 Other unpredicted reasons If you don t agree with the above clauses within three days from you purchase you can send it back if only it is not damaged and we will refund all money Otherwise we view it as that you agree with the above clauses You should known that the alarm equipment is not insurance substitution so he users must be careful to protect your life and property Jan 2007 Publish
9. directives Then you can press 4 on telephone keyboard to monitor on the spot for 20 seconds after that you will hear a short Di sound again if you want to go on monitoring you can press 4 again If you enter 3 it will alarm on the spot with the loudest volume and if you enter 2 main unit will disarm and stop alarming on the spot If you don t want it to dial other telephone numbers you can press 1 main unit will enter arm state immediately and press 0 to exit from telephone answering state and hang telephone down If there are no effective operations within 20seconds main unit will hung telephone down automatically and then go on dialing other telephone numbers Note Please arm the main unit in time to avoid missing any alarm in formation 8 5How To Operation Remotely Only B model have this function Instruction When operating a short Di sound means the operation is valid and two long Di sound means the operation is invalid Dialing the number of telephone which connects with main unit through fix phone or mobile phone When the ringing times 8 times by default you set arrives main unit will make a short Di sound then you can press 6 bits of user s code 000000 by default on your phone keyboard If the code is incorrect main unit will make Di Di sound and then you can reenter the code again and press to confirm If incorrect code was entered for three times continu
10. in the lowest 22 Alarm sound is in the middle 23 Alarm sound is louder 24 Alarm sound is the loudest 25 DD Alarm duration DD 00 99 Minutes 30 minutes by default 26 DD Leaving time DD 00 99 Seconds 00 second by default 27 DD Entry time DD 00 99 Seconds 00 second by default 28 DD Ringing times DD 03 15 Times 08 times by default 29 DD Cycle dialing times DD 03 15 Times 03 times by default 34 Open telephone line test function 35 Close telephone line test function 36 Open advise function when armed disarmed 37 Close advise function when armed disarmed by default 38 Open advise function when power lower 39 Close advise function when power lower by default A0 AAAAAAAA Enter code of wireless siren Open wireless siren 40 Delete Wireless Siren Close wireless siren by default 20 Manager s Program Directives Code 12 48 0 Exit from programming state O1l Recover user s code to be 000000 11 Learn the first detector in the first zone 12 Learn the second detector in the first zone 13 Learn the third detector in the first zone Deduce by analogy 81 Learn the first detector in the eighth zone 82 Learn the second detector in the eighth zone 83 Learn the third detector in the eighth zone 11 Delete the first detector in the first zone 12 Delete the second detector in the first zone
11. is not standard DTMF one 1 Correctly connect telephone line with outside line 2 Supply power with AC 3 Change a telephone set which Is standard DTMF one Wireless sensor send fault alarms frequently The sensor is installed in incorrect place Please install the sensor in the right Place according to requirements The telephone can not dial out while alarming 1 The outside line is parallel connecting with extension 2 The telephone is not standard DTMF 3 The telephone number is wrong 4 The telephone attribute is wrong 5 The telephone outside line is IP telephone phone or other special lines 6 Parallel connected with fax or ADSL broadband equipments 1 Extension should be connected with the telephone socket of main unit but don t connect with the outside line 2 The telephone should be standard DTMF 3 Enter the correct telephone number 4 Set telephone attribute to be the same 5 This unit can t dial through IP telephone number or other special lines 6 Some external equipment will affect the normal dialing False Alarm 1 The installation of main unit and detector can t meet the requirements 2 Battery power is low 1 Install main unit and detector according to install requirements 2 Replace the battery Backup battery can t work Normally 1 Battery is badly connected 2 Wrongly connected the polarity 3 Battery is used up 1
12. when entering telephone numbers Delete Directive If you delete anything there should be an indication if the operation is successful that is all zone lights are on at the same time and then be off one by one then the main unit will make four short Di sound If there are no any operations for 60 seconds after entering setting state the system will exit from setting state automatically You can exit setting state by pressing SET button at the back of main unit and the SET indicator light will be off which means it has exited from setting state 5 2Specific Operation Entering into setup state Well connect main unit with telephone line power on main unit and press SET button at the back of main unit for 3 seconds SET indicator will be on and wait for 2 seconds before picking telephone receiver up and then enter XXXXXX XXXXXX is 6 bit user s code and it is 000000 by default If the code is incorrect main unit will make two long Di sounds and then exit from setting state automatically If the code is correct main unit will make four short Di sounds and then you can program as following directives 5 3 User s Setting lt 1 gt How To Set Zone List Of At Home Mode 12345678 by default O1 XXXX X is any number ranges from 1 to 8 and they separately stands for 1 8 zones Instruction Main unit will make a Di sound after entering 01 then the indicator light of the
13. which means the remote controller has been B learned in this zone and if the indicator light is off which means no remote controller has been learned in this zone 2 This directive only used to display the indicator lights and it won t modify any settings Example 1 Two remote controllers has been learned to be the fifth and seventh remote controller In manager s program state enter 99 then the indicator light of the 5 and 7 zone will be on and the indicator lights of other zones will be off If you want to exit displaying state only enter a then it will make four short Di sound which means the setting is successful 7 System Installation 7 1Testing Before Installation Well connect all lines according to the fourth chapter and then power on main unit Power on other accessories such as wireless door sensor PIR detector wireless external siren and so on 8 Check to see whether all accessories are correct or not and test to see whether all settings such as dialing function at home away home zone list are meet your requirements or not after checking power main unit and all accessories down then begin to install 7 2 Install Requirements 0D Firstly make a scheme of all defense zones according to user s needs and the surroundings and keep in file Fix the install place angle and height of all fittings main unit according to the valid defense area And they should be installed as cove
14. zones at home mode will be on then you can enter the zone number which you want it to be at home mode And the state of indicator you set is the same as that of at home mode After that press to confirm and it will make four short Di sound which means the setting is successful lt 2 gt How To Set Zone List Of Away Home Mode 12345678 by default O2 XXXXX Xis any number ranges from to 8 and they separately stands for 1 8 zones Instruction Main unit will make a short Di sound after entering 02 then the indicator light of the zones away home mode will be on then you can enter the zone number which you want it to be away home mode And the state of indicator you set is the same as that of away home mode After that press to confirm and it will make four short D1 sound which means the setting is successful lt 3 gt How To Define Zone Type 1111 1111 by default O3 XXXXXXXX Instruction XXXXXXXX should be 8 bits and X is any number ranges from 0 to 6 and 0 6 are separately stand for as following Code Type Instruction 0 Bypass Zone This zone is unused at the moment 1 Anti theft Zone It is controlled by arm disarm 2 Medical Zone It is uncontrolled by arm disarm 3 Fire Zone It is uncontrolled by arm disarm 4 Gas Zone It is uncontrolled by arm disarm 5 Emergency Zone It is uncontrolled by arm disarm 6 Doorbell Zone It will make doorbell sound when triggered
15. 3 seconds SET indicator will be on and it needs to wait For 2 seconds after picking up receiver Enter 12 48 12 48 is the code of manager and can not be modified If the code is incorrect then SET indicator will be off and then exit from setting state automatically If the code is correct it will make four short Di sounds then you can go on programming as following After finishing programming press SET button at the back of main unit for 3 seconds and the SET indicator will be off and then exit from setting state automatically lt 1 gt How To Recover User s Code Ol Instruction After entering 01 all indicator lights will be off one by one and then it will make four short Di sound which means the setting is successful and the user code will recover to the ex factory state that is 000 000 lt 2 gt How To Register Detector 11 to register the first detector in the first zone 12 to register the second detector in the first zone 13 to register the third detector in the first zone 81 to register the first detector in the eighth zone 82 to register the second detector in the eighth zone 410 83 to register the third detector in the eighth zone The first bit stands for zone number and the latter bit stands for the number of detectors in this zone and means to confirm Example 1 Registering a PIR detector in the third zone and register a wireless door sensor in the
16. Frequency 433 92MHz Emit Distance 1 800m in open area Detect Angle 90 right and left Size 55X90X38 mm 9 3Wireless Door Sensor 9 4Working Voltage 12V23A Standby Current lt 5uA Alarm Current lt 16 5mA Wireless Emit Frequency 433 92MHz Emit Distance 1 500m in open area Size 33 X63X16 mm 9 5Wireless Remote Controller Working Voltage 12V27A Standby Current lt SuA Emit Current lt 10mA Wireless Emit Frequency 433 92MHz Emit Distance 1 300m in open area Size 35X61X14 mm 10 Standard Packing List Name Quantity User s Manual 1PC Main Unit 1PC Wireless Remote Controller 2PCS Wireless Door Sensor 1PC Wireless PIR Detector 1PC Double end Telephone Line 1PC 11 Optional Packing List Name Wireless Remote Controller Wireless Door Sensor Wireless PIR Detector Wireless Emergency Button Wireless Smoke Detector Wireless Gas Detector Wireless Siren AA Ni MH Rechargeable Battery 12 Frequently Ask Questions Question Reason Answer The power indicator light cannot be on when powered on 1 The power socket may be bad or badly connected 2 There is no power supply 1 Check and connect the socket 2 Power the socket on You can t enter program state 1 Wrongly connect telephone line with outside line 2 Don t supply power with AC 3 The telephone
17. User s Manual Table Of Contents 1 Main Functions And Characteristics 1 2 Operate Precautions 1 3 Name And Usage Of Main Parts 2 4 Diagram Of Connection 3 5 Program Of Main Unit 4 5 1 Program Precautions 4 5 2 Specific Operations 5 5 3 User s Setting 5 lt 1 gt How To Set Zone List Of At Home Mode 5 lt 2 gt How To Set Zone List Of Away Home Mode 5 lt 3 gt How To Define Zone Type 5 lt 4 gt How To Modify User Code 6 lt 5 gt How To Set Alarm Volume 6 lt 6 gt How To Set Inner Siren Duration 6 lt 7 gt How To Set Delay Arm Time 7 lt 8 gt How To Set Delay Alarm Time 7 lt 9 gt How To Set Wireless External
18. default O044XXXXXXXX X should be 8 bits and they stand for the attribute of 1 8 groups of telephone numberas following Code Instruction 0 This group is unused at the moment 1 Common alarm telephone 2 CONTACT ID monitor center telephone 5 Power lower inform telephone Instruction After entering 04 main unit will make a short Di sound and enter 8 bits of number as above then press a to confirm then it will make four short Di sound which means the setting is successful lt 4 gt How To Set Cycle Times Of Dialing 05 times by default 29 DD Instruction DD is the cycle dialing times which ranges from 03 to 15 and it should be 2 bits when entering when main unit occurs alarm it will dial the alarm telephone number from the first group to the last group and it means one cycle When the cycle dialing times you set arrives main unit will hang telephone up and stop dialing at the same time But if main unit occurs alarm again it will cycle dial again lt 5 gt How To Open Close Telephone Line Cut Detecting Function Close by default 34 Open telephone line cut detecting function 35 Close telephone line cut detecting function Telephone line cut detecting function When the telephone line connected with main unit is cut or there occur short circuit main unit will make an urgent indicate sound lt 6 gt How To Set Ringing Times Of Operation Remotely 08
19. er Example 1 Register two remote controller separately to be the number one and number three In manager s program state enter 91 and the indicator light of the first zone is flashing then press Disarm key on remote controller it will make four short D1 sound which means the setting is successful then the indicator light of the first zone will be off Then enter 93 and the indicator light of the third zone is flashing and then press Disarm key on remote controller it will make four short Di sound which means the setting is successful then the indicator light of this zone will be off lt 6 gt How To Delete Remote Controller 91 to delete the first remote controller 98 to delete the eighth remote controller 03 to delete all remote controllers at one time Example 1 Delete the third remote controller In manager s program state enter 93 and the indicator light of the third zone is flashing then press a all indicator lights will be off one by one then it will makes four short Di sound which means the setting is successful Example 2 Delete all remote controllers In manager s program state enter 03 and all indicator lights will be off one by one then it will make four short Di sound which means the setting is successful lt 7 gt How To Display Registered Remote Controller 99 Zone Number Indicator light which you want to display Instruction 1 If the indicator light is on
20. ess this key main unit will make alarm sound immediately Picture 5 3 Wireless Door Sensor Magnetic Part Emit Indicator Power Indicator Sensor Par Should not beyond1 0mm Picture 6 The distance between magnet part and sensor part should not beyond 10mm The magnetic part should be installed in moveable place such as door or window and the sensor part should be installed in the fix place Pull the antenna out to get the best receive effect Emit Indicator light Red If this light is on which means it is sending alarm signal Power Indicator Red If this light is on which means battery power lower then you should change the battery in time 4 PIR Detector Please refer to the corresponding part 5 Smoke Detector Gas Detector Please refer to the corresponding part 7 4 Testing After Installation After installing all main unit and accessories please power them on to test and make sure the installation is valid and credible 8 User s Operation 8 1All Indicate Sound Of Main Unit 1 Leaving Time zas Main unit will make a short Di sound every one second and it arms in away home mode automatically when the leaving time preset arrives 2 Arm automatically when powered on After power on main unit it will make a short Di sound every one second and it arms in away home mode automatically after 60 seconds 3 Indicate when there are so
21. fourth zone Register PIR detector in the first one of the third zone so the code is 31 Register wireless door sensor in the first one of the fourth zone so the code is 41 In manager s program state enter 31 and the indicator light in the third zone is flashing and then trigger the PIR detector to send signal it will make four short Di sound which means the setting is successful then the indicator light in the third zone will be off Then enter 41 and the indicator light in the fourth zone is flashing and then separates the sensor part with the magnetic part it will make four short Di sound which means the setting is successful then the indicator light in the fourth zone will be off Note If it learns other wrong signals please delete it according to the 6 3 chapters and then learn code again lt 3 gt How To Delete Detector 11 to delete the first detector in the first zone 12 to delete the second detector in the second zone 13 to delete the third detector in the third zone 81 to delete the first detector in the eighth zone 82 to delete the second detector in the eighth zone 83 to delete the third detector in the eighth zone 04 to delete all detectors Example 1 Delete the third detector in the fifth zone In manager s program state enter 53 then the indicator light in the fifth zone is flashing and then press a and all indicator lights will be off one by one then it will make four s
22. g Times 8 Times Cycle Dialing Times 3 Times Telephone Line Test Function Closed Arm Disarm Report Monitor Center Closed Power Lower Report Monitor Center Closed Wireless Siren Closed O Warning Limits Of This Safe System As an advanced technical guard system although it can reduce the occurrence of theft robbery and fire it can not promise to have no any above mentioned accidents happens or have no any personnel casualty or property losses happens And we invite you understanding that any alarm system whether it is used in business or at home it may false alarm or failure to alarm because of various reasons We remind you to pay attention to the following possible reasons 1 The system is not armed because of carelessness 2 User or installation personnel misunderstand the user manual or operate wrongly so that the system cannot work normally 3 Intruder intrude the place where is beyond the detect areas or he can pass by the alarm detector or make it malfunction Passive infrared detector cannot detect hidden places like behind the wall inside ceiling inside floor behind the door glass partition glass door or behind the glazing 4 The detect sensitivity of passive infrared detector will automatically change according to the changed environment temperature when the temperature of protected area reach to 32 C 40 C the performance of infrared detector detect distance will reduce So we suggest you to
23. hort Di sound which means the setting is successful Example 2 Delete All Detectors In manager s programming state enter 04 and all indicator lights will be off one by one then it will make four short Di sound which means the setting is successful lt 4 gt How To Display Registered Zones 19 Instruction A Ifthe indicator light is on which means some detector has been learned in this zone and if the indicator light is off which means no detector has been learned in this zone B A zone can be learned up to three detectors that is to say the indicator 4 il light will be on as long as one detector has been learned in this zone C This directive only used to display the indicator lights and it won t modify any settings Example 1 Learn one detector in the first zone learn 2 detectors in the second zone learn 3 detectors in the third zone and don t learn any detectors in the other zones In manager s programming state enter 19 and then the indicator lights of 1 2 3 zones on main unit will be on and other indicator lights on main unit will be off If you want to exit displaying state only enter a then it will make four short Di sound which means the setting is successful lt 5 gt How To Register Remote Controller 91 to register the first remote controller 98 to register the eighth remote controller The first bit should be 9 and the second bit stands for the number of remote controll
24. iately Pothook Hang this main unit with those two pothooks 4 Diagram Of Connection PHONE LINE 220VAC Telephone Line Picture 4 5 Program Of Main Unit 5 1Program Precautions The phone should be standard DTMF double tone multi frequency and the power of telephone is provided by AC power so please pick receiver up instead of free hand when programming Main unit only can be programmed in disarm state and it will delete all alarm information and power lower information after entering into setup state therefore before entering setup state please check whether to keep records firstly or not After entering setup state please arm the main unit in time to avoid missing alarm message After entering into setup state the telephone will cut with outside line and there should be no any dialing tone If there are no indicate sound when pressing telephone keyboard please check to see weather the lines are correctly connected if the connection is correct please try another telephone set Main unit will make a short Du sound every time pressing keyboard on telephone therefore during setting you can adjust wheather the operation is valid or not according to the sound made by main unit Four short Di sound The operation is effective Two long Di sound The operation is ineffective Press key to delete if you press wrong information except
25. illegally main unit will make alarm sound Emergency ask for help You can press Emergency button on remote controller in emergency situation and main unit will makealarm immediately 8 4How To Operate When Receipt An Alarm When receipt of alarm telephone you will hear alarm sound for 10 seconds and then you will hear a short Di sound and then you can enter as following 45 Directive Function 1 Arm Away home mode 2 Disarm 3 Alarm sound on the spot 4 Monitor 0 Exit from telephone answering state Instruction If the directive is correct you will hear a short Di sound If the directive is incorrect you will hear two long Di sound If you don t enter correct directives for 5 seconds then you will hear alarm sound for 10 seconds again then it will wait for directives for 5 seconds and it will hang up automatically after repeating for 3 times but it also will dial this phone number in next cycle If you enter any correct directive then it will not dial this phone number in next cycle unless alarm occurs again If you enter directive to disarm the main unit then it will not dial any telephone numbers unless alarm occurs again After disarming remember to arm it in time When receipt of alarm telephone number you will hear alarm sound for 10 seconds and then you will hear a short Di sound and the system will wait for 5 seconds to receive
26. in unit will make a Di sound and then enter a and the indicator Light will be off one by one then it will make four short Di sound which means the setting is successful 5 4 Telephone Setting lt 1 gt How To Set Telephone Numbers Empty by default Directives Instruction 11 Telephone Number Set the first group of telephone number 12 Telephone Number Set the second group of telephone number 13 Telephone Number Set the third group of telephone number 14 Telephone Number Set the fourth group of telephone number 15 Telephone Number Set the fifth group of telephone number 16 Telephone Number Set the sixth group of telephone number 17 Telephone Number Set the seventh group of telephone number 18 Telephone Number Set the eighth group of telephone number Instruction A During entering telephone number every time entering a which means it will go on dialing after pausing for 2 seconds And the number of is subject to the difference of exchanger and they are mainly used in small exchanger group telephone and so on B Each group of telephone number including should be 20 bits at most C If there are some groups of unused telephone numbers you don t need to enter And if the code is wrongly entered then you should delete it firstly and then enter the new number Refer to 5 4 2 chapter Example 1 Set the first group of tele
27. mething wrong with telephone line Main unit makes four urgent Di Di D1 Di sound which means there are something wrong with telephone line then please check to see if the line is loosed After excluding the malfunction main unit will stop indicate for 1 minute If you want to close this function please refer to 5 4 5 chapter for specific operations 4 Doorbell Indication Main unit makes Ding dong sound which means some doorbell zone has been triggered 5 Power Lower Indication Main unit makes a long Di sound every 15 seconds which means there are power lower occurs in some detector or main unit If there are power lower occurs in main unit then the power indicator light of it will be flashing then please charge in time If there are power lower occurs in detector then the indicator light of this detector on main unit will be Lashing quickly then please change battery in time A fter precluding malfunctions re power main unit on and arm it in time 8 2Indications When Power On Main Unit After powering main unit on indicator lights of away home mode and power indicator will be on then main unit will make a Di sound every second and then arm in away home mode automatically after 60 seconds 8 3How To Make An Alarm Anti theft If you want to leave your home or office you can set the main unit to be in arm state of away home mode and the main unit will enter into arm state Once somebody intrudes
28. ne line cut off or open circuit All the settings are stored and won t lose even if power off 2 Operate Precautions Please carefully read this user s manual before operating and note all labels on main unit The main unit is not explosion proof so it cannot be directly installed in Zj hazard class I II or III locations i e Where there have flammable and explosive steam gas dusts of some certain concentration otherwise it will be very dangerous The backup battery should be AA 1 2V Ni MH rechargeable battery and one off dry battery is banned otherwise it will be very dangerous The user should not dismantle main unit by oneself Please check routinely so as to clear troubles in time to avoid missing alarms 3 Name And Usage Of Main Parts 3 1 Front Panel Of Main Unit Picture 1 POWER Indicator Green This light will be on if power supply is normal and it will be flashing if the backup power of main unit is lower SET Indicator Orange This light will be on when main unit enter setting state and it will be off when main unit exit from setting state ALARM Indicator Red This light will be on when main unit occurs alarm At Home Mode Indicator Red If this light is on which means it is in arm state ofat home mode Away Home Mode Indicator Red If this light is on which means it is in arm state of away home mode Zone Indicators Red Those eight indicators separately s
29. ously the phone will hung up automatically and exit from setting state If the code is correct main unit will make a short Di sound and wait for directives for 20 seconds and then you can enter as followings 1 Arm in away home mode by default 2 Disarm 3 Start Alarm Sound O Exit from controlling state If the code is correct you will hear a short Di sound and main unit will wait for directives for 20 seconds and then you can enter directives through keyboard of fix phone or mobile phone If you enter 3 main unit will make alarm sound on the spot Enter 2 main unit will disarm immediately and enter 1 main unit will arm immediately Press 0 main unit will exit from controlling state If there are no any valid operations for 20 seconds main unit will hang up automatically 9 Technical Parameter 9 1Main Unit A B model Working Voltage AC220V 15 50Hz Working Current Standby Current lt 26mA Alarm Current lt 350mA Battery Standby Time 224 hours Working Environment 10 C 55 C Relative Humidity 40 70 Dialing Mode Double Frequency High Frequency Level 7 3dBm Low Frequency Level 9 3dBm Wireless Receive Frequency 433 92MHz Alarm Loudness 80dB within meter Backup Battery 8PCS AA 1300MAh 1 2V Ni MH rechargeable backup battery Size 185X135X46 mm 9 2Wireless PIR Detector Working Voltage 4PCS AAA alkali battery DC 6V Standby Current lt 35u A Alarm Current lt 20mA Wireless Emit
30. phone number to be 1234567 11 1234567 Example 2 Set the second group of telephone number to be 1234567 and the extension number to be 801 12 1234567 801 Note If the pausing time of exchanger is more than 2 seconds then you should enter like this 12 1234567 801 and the number of is subject to the needs lt 2 gt How To Delete Telephone Numbers Directives Instruction 11 Delete the first group of telephone number 12 Delete the second group of telephone number 13 Delete the third group of telephone number 14 Delete the fourth group of telephone number 15 Delete the fifth group of telephone number 16 Delete the sixth group of telephone number 17 Delete the seventh group of telephone number 18 Delete the eighth group of telephone number 19 Delete all groups of telephone number Example 1 Delete the second group of telephone number Enter 12 after hearing a short Di sound then enter a and all indicator lights will be off one by one then it will make four short Di sound which means the setting is successful Example 2 Delete all groups of telephone number Enter 19 after hearing a short Di sound then enter a and all indicator lights will be off one by one then it will make four short Di sound which means the setting is successful lt 3 gt How To Set Telephone Attribute Common alarm telephone number by
31. rt as possible When installing wireless accessories under user s needs are satisfied the distance between them and main unit should be as short as possible to get the best receive effect Main unit and all wireless accessories should far away from the equipments which will emit strong electromagnetic radiations such as television air conditioner computer micro oven and so on The drawing should clearly marked the model and place of main unit and all detectors and keep in filefor afterwards maintenance 7 3Installation And Debugging Of Main Unit And Accessories 1 Main Unit The position of microphone and trumpet of main unit should not be covered to get the best monitor sensitivity and alarm loudness To assure the normal working of this system backup battery is recommended To get the best receive effect please pull the antenna out 2 Wireless Remote Controller 4 O Emit Indicator If the light is on which means it is sending signal if the light cannot be on please change the battery Arm In Away Home Mode Press this key main unit will make a short Di sound then the main unit will be in arm state of away home mode Disarm Press this key main unit will make four short Di sound then the main unit will be in disarm state Arm In At Home Mode Press this key main unit will make a short Du Sound then the main unit will be in arm state of at home mode Emergency Alarm Pr
32. tand for 8 zones from 1 8 Ifthe indicator is on which means this zone is in arm state If the indicator is off which means this zone is in disarm state If the indicator is flashing slowly 1 time every second which means there is alarm occurs in this zone If the indicator is flashing quickly 3 times every second which means power lower of some detector occurs in this zone Trumpet Build in trumpet 3 2Back Components Of Main Unit Picture 2 City Inputting AC 220V 15 50Hz Inputting Power SET Button Enter setting state by pressing and holding this button for 3 seconds and exit from setting state by pressing and holding this button for 3 seconds Telephone Socket It is used to connect with telephone set Outside Line Socket It is used to connect with outside line of telephone Antenna It is used to send receive wireless signals pulling it out is recommended to assure to get the best effect 3 3 Bottom Components Of Main Unit Picture 3 Microphone It is used to monitor Anti slip footpad It prevents main unit from slipping on glaze surface Backup Battery Case Open the case and put 8 PCS AA Ni MH rechargeable batteries in the battery case according to the labels and then close the case Note Please note the polarity It is not allowed to open battery case when main unit is in working state otherwise it will alarm immed
33. times by default Only B model have this function 28 DD Instruction DD is the ringing times of operation remotely which should be 2 bits and it ranges from 05to 15 When the ringing times you set arrives main unit will enter into remote setting state automatically And you can refer to 8 4 chapters for specific operations 5 5 Alarm Monitor Center Setting Only B model have this function 20 lt 1 gt How To Enter Alarm Monitor Center Accounts 0000 by default OS HAAAA AAAA should be 4 bits which ranges from 0 to 9 Instruction Entering 05 it will make a short Di sound and enter 4 bits of alarm monitor center accounts then press a to confirm it will make four short Di sound which means the setting is Successful lt 2 gt How To Set Report To Monitor Center When Arm Disarm Closed by default 36 Openreport function when arm disarm 37 Close report function when arm disarm Instruction when main unit is connecting with monitor center whether to send arm disarm report to monitor center lt 3 gt How To Set Lower Power Report To Monitor Center 38 Open lower power report function 39 Close lower power report function Instruction Whether to inform manage center or not when main unit detector power lower 6 Manager s Setting How To Enter Manager s Program State Well connect main unit as picture 4 in the fourth chapter then power on main unit Press SET button at the back of main unit for
34. uring the time When delay arm time you set arrives main unit will enter into away home mode immediately If you set to be 00 second then once you press Away Home button on remote controller main unit will enter away home mode automatically lt 8 gt How To Set Delay Alarm Time Entering Time 00 second by default 27 DD Instruction DD is delay alarm time which ranges from 00 to 99 and it should be 2 bits Delay alarm time is only valid to anti theft zones If you enter the defense area which has been armed then you can disarm the main unit by remote controller during the delay alarm time if you don t disarm main unit during the time it will make alarm sound when the time arrives If the time set to be 00 second main unit will make alarm sound immediately when receiving alarm signal lt 9 gt How To Set Wireless External Siren Closed by default Only B model have this function A Enter The Code Of Wireless Siren This function open automatically after entering the code of siren 40 AAAAAAAA AAAAAAAA is the code of siren Instruction After entering 40 main unit will make a short Di sound and then enter 8 bits code of siren labeled at the back of siren and press a to confirm then it will make four short Di sound which means the setting is successful B Delete The Code Of Wireless Siren This function close automatically after deleting the code of siren 40 Instruction After entering 40 ma
35. with you therefore it is very suitable to be widely used in family shop and so on 1 Main Function And Characteristics Compatible with ADEMCO CONTACT ID networking form Only B model have this function 24 wireless detectors and 8 remote controllers can be learned and it learns code automatically and wirelessly At home mode and away home mode are optional and the zone type is modifiable It stands for wireless siren Only B model have this function Remotely Operation It can be armed disarmed remotely by entering code through fix telephone or mobile phone Only B model have this function It indicates by sound and light when power lower of main unit or detector and dials telephone number preset at the same time It rushes to inform you the alarm message by cutting your speaking on the telephone and then recovers automatically 8 groups of telephone numbers can be set and the type of each group is modifiable 4 levels of alarm volume are adjustable and it also can be set to be mute When networking the message of main unit such as arm disarm power lower and so on can be reported to manage center Only B model have this function Usually the backup battery charges automatically and it automatically switches between AC and battery power The alarm information can be recorded and can t be deleted until confirmed Delay arm time delay alarm time are modifiable It will indicate when telepho
Download Pdf Manuals
Related Search
Related Contents
三菱保護継電器 高圧受配電用 MELPROTM このたびはノボルカセッ 卜付オルゴールアンブYR一62C/ YR一62GパR LG LRM LRM-519 User's Manual C112V/C115V/C215V CM10V/CM12V/CM15V C112VA/C115VA Aston SEN980-CH-40-8-R Installation Guide Suresnes Magazine - N°267 Bosch GBH 2-26 DFR Craftsman 351.22313 Owner's Manual Toastmaster 597U Hot Beverage Maker User Manual Copyright © All rights reserved.