        MAN074 - Model 1050 Syringe Filling System User Guide
         Contents
1.     de Star Nut    Star Nut          Cartridge Retainer    Cartridge Mating Fitting    Fluid Path    Model 1050 Syringe Filling System User Guide    Install the Fluid Path    1     Remove the four 8 32 x 0 75  Screws  Figure 9  that hold the Tube Support and the Valve Body  together     Evenly loosen the two Luer Block Clamp Screws  Figure 8  enough to slip the Luer Tip Cap through the  opening  Position the Fluid Path in the Luer Block Clamp so that the left edge of the Luer Block Clamp  just catches the white Luer Tip     Evenly tighten the two Luer Block Clamp Screws     Install the Fluid Path and the Tube Support to the Model 830 Valve  Figure 8   The Tube Support has  two access holes for the over pinch and suck back adjusts at the top of the cover and must be  installed in the correct orientation  Evenly tighten the two Tube Support Removal Screws     Figure 8  Luer Block Clamp       Model 1050 Syringe Filling System User Guide    Figure 9  Fluid Path Installation            i j 8 32 x 0 75   Screws  4     I Pi Washers  4     GD  AR  t     aue   Qe       Tube Support       of    Assembled Unit       Fluid Path   Tubing    Suck Back Adjust    Over Pinch Adjust    Valve Body    NOTE  Follow the same assembly and replacement for the following filling configurations     715225 TUBE ASSEMBLY  LUER FEMALE    Model 1050 Syringe Filling System User Guide    Pressurizing the System    NOTE  Before operating the machine at the beginning of each run  check that all tubes  covers  
2. 5 psi will make it easier to see the air being purged     Prepare the Syringes    Before filling each syringe  ensure the syringe plunger is fully inserted to the tip of the syringe to remove most  of the air from the empty syringe     Fill the Syringe  1  Remove the Cap from the Luer Tip   2  Loadthe required Syringe size by threading it onto the Luer Tip  Figure 10      3  Make sure all hands and fingers are clear of the machine  Press and hold the Foot Switch to activate  the filling cycle     4  Release the Foot Switch when the Syringe Plunger touches the Syringe Fill Stop   5  Remove the Syringe from the Luer Tip   6  Capthe Syringe Tip and the Syringe End as needed     7  Repeat above steps 2 through 6 for each additional syringe needed     Model 1050 Syringe Filling System User Guide    Model 830 Valve Adjustments    The 830 valve highlights a suck back feature to prevent oozing and dripping between syringes  Depending on  the type of fluids used  the suck back feature will require adjustment  Batch to batch adjustment is  recommended  If material drips  suck back should be increased  If there are air bubbles in the syringe     decrease the amount of suck back     Adjusting Suck Back Position  Front     The Adjustment Screw is located on the top face of the valve  To increase suck back  loosen the adjustment  screw counter clockwise  To decrease suck back  tighten the adjustment screw clockwise   Figure 11     Figure 11  Suck Back Adjustment Screw       Increase Suck B
3. System Pressure Inlet     Set the Fill Amount for the Syringe Size    For the required syringe size  use the scale to set the fill volume by adjusting the syringe fill stop to the desired  location     1  Disconnect the Compressed Air Supply from the System Pressure Inlet   2  By hand  set the Syringe Plunger to the desired fill mL volume     3  Twist or slide the Syringe and extended Plunger on to the Nozzle Needle Luer Lock Tip of the Fluid  Path     4  Loosen the Syringe Fill Adjustment Lock by loosening the bottom two Allen Cap Screws  Figure 10      5  Ensure the Syringe Fill Stop is    at rest     and not extended     Model 1050 Syringe Filling System User Guide    6  Move the Syringe Fill Stop to the position where it immediately touches the extended Syringe  Plunger     7  From this position  gently slide the Syringe Fill Stop 5 scale lines away from the Syringe Plunger  The  Syringe Fill Stop will retract to this position when each syringe reaches the desired fill volume     8  Re tighten the Syringe Fill Stop using Allen Cap Screws     Figure 10  Model 1050 with Syringe Inserted       Priming the System    During initial setup and when changing material cartridge reservoirs  air must be purged from the disposable  fluid path fill tube to prevent accidental spills and introducing bubbles into syringes  Prime the system by  running material through the fluid path until a constant  solid flow of material is achieved  Depending on  material  reducing the pressure by 5 1
4. Tridak Model 1050 User Guide    Syringe Filling System      Instructions for Safe Use    Setup and Operation      Maintenance      Ordering Spare Parts and Accessories       Tridnk    Model 1050 Syringe Filling System User Guide    About Tridak   A Dymax Company  Systems for fluid packaging     Tridak manufactures fluid packaging systems for a variety of industries including industrial  medical  dental  pharmaceutical  and food  preparation  Tridak   s filling systems for syringes and cartridges provide significant productivity gains over manual and other more  complicated and costly filling methods  The equipment is suited for all industry standard packaging as well as custom molded syringes and  cartridges  Tridak possesses the capability to fabricate nozzles and multi port dispensing manifolds that perfectly match the packages  being filled  Single component and dual component materials can be packaged in seconds  one at a time  or in multiples for higher volume  throughput  High pressure filling equipment is available for packaging highly filled materials in tiny syringes or compoules     Please note that most filling system applications are unique  Tridak does not warrant the fitness of the product for the intended  application  Any warranty applicable to the product  its application  and use is strictly limited to that contained in the Tridak standard  Conditions of Sale  Tridak recommends that any intended application be evaluated and tested by the user to ensure that 
5. ack  Counter Clockwise  Decrease Suck Back  Clockwise     Cleaning and Maintenance    System Cleaning    Switching to a Different Material    The disposable fluid path in the Model 830 valve allows for quick and easy material changeover  To switch  your system over from dispensing one material to dispensing a new material  simply replace the fluid path  tube in the dispensing valve  You will also need to replace the material reservoir on the system  The new  material can be placed in a new material reservoir or the existing reservoir can be cleaned and the material    replaced     Model 1050 Syringe Filling System User Guide    Spare Parts and Accessories    Replacement Parts Accessories    Part Number Item    Air Lines  amp  Regulators   T16789 Air Supply Line   T18297 Regulator Assembly   Reservoir Cartridge Kits   T18306 2002 Cartridge Assembly HDPE   T18307 3202 Cartridge Assembly HDPE   Luer Block Parts   T18294 Modified Thumb Screw 10 32  amp  V Block Top  1050  Model 830 Parts   T18196 Valve  Model 830    Spare Parts Kit  Includes  Modified 1050 Thumb Screw  Model 830 Thumb Screw  830 Hardware Kit    T18304    Tube Assemblies    T15225 Tube Assembly  Luer Female   T18305 Tube Assembly  No Tip  For Use with Custom Tooling   Misc    T18218 Bleed Wire with Pull Ring   T16603 Foot Switch Assembly Pneumatic  1000   T18296 Stopper Assembly    Specifications    System Specifications    Materials of Construction   Wetted Parts    Dispensing valve   No wetted parts    Fluid tub
6. al  reservoirs including cartridge reservoirs  bottle reservoirs  and pail reservoirs  The system utilizes a Model 830  disposable fluid path valve to make material changeover fast and easy  while eliminating most cross   contamination  The disposable fluid path can be fitted with a series of adapters to fill Luer Lock and Oral tip  syringe types     Special Features and Benefits of the Model 1050  This machine features several design features to make filling simple  quick and clean  including     Disposable fluid path valve with disposable wetted parts that eliminate material contamination and  minimize clean up and maintenance    Disposable fluid path can be capped and remain attached to the material cartridge for storage     Adjustable suck back feature allows for a clean dispense of stringy and tacky materials     Material reservoir pressure regulator to control the reservoir pressure used for filling      Fills various syringes including 0 5  1  3 and 5 ml  up to 60 ml  syringes with pre inserted plunger   tooling nozzles are available for both Luer Lock or Oral tips        Adjustable pneumatic stop assures accurate fills     Foot switch for hands free fill cycle activation      Small footprint  Dimensions  Lx W x H    23 6 in x 12 in x 25 in  60 cm x 30 48 cm x 63 50 cm     Description of Main Components    The main components in the Model 1050 Syringe Loader filling system include     1  Air Precision Regulator     The air precision regulator enables you to precisely c
7. desired  performance criteria are satisfied  Tridak is willing to assist users in their performance testing and evaluation  Data sheets are available for  pressure pots upon request     Model 1050 Syringe Filling System User Guide    Contents    IMEPODU CHO                                                                                                           4  Introduction TO the USEF Guilde    ore ERR eR Rer etate ie Hae ep renis lage n ER E een SEE eed 4  C semdiis                                                                            4   SAT CUY                                                                                                                4  General Safety Considerations osese onie oiiae E E a rus Ee NR Ar TRASEE EEES EN E E EES ESR SES 4  Specific Safety Considerations    iecit acetic repa ici ase adig id dea basata AR ea baee e dde aa aged 4  Personal  Protective Eqdiprmierit    3  ceo cete ed E OE INE Oc Rd ee Or EUR 5    Product Overview        Description of the Model 1050 Syringe Filling System       Special Features and Benefits of the Model 1050                  ssessssssessseeseeeee enne nennen ener nnn nennen nnns 5  Description of Main COMPONENMS          ccecccescccssecssecsseeesseecsuscssescsseecuecsaeeseeesseecsaeesaeecsaeesnessaeessessseeeseneeeaeessnesseneseasesseeess 5  Assembly and                                                                          7  Unpacking and Inspecting Your Shipment    eene enne nnne nnne nennen nennen 
8. eee e ese Use debe ES 17  Specification S EE TETTE EE                               17    System Specifications M                                                                      17    Model 1050 Syringe Filling System User Guide    Introduction    Introduction to the User Guide    This guide describes how to assemble  use  and maintain the Model 1050 Syringe Filling System filling system    safely and efficiently     Intended Audience    Tridak prepared this user guide for experienced process engineers  technicians  and manufacturing personnel   If you are new to filling systems and do not understand the instructions  contact Tridak Application  Engineering to answer your questions before using the equipment     Where to Get Help    Additional resources are available to ensure a trouble free experience with our products     m Detailed product information on www tridak com    m Customer Support and Application Engineering teams are available in the United States  Monday  through Friday  from 8 00 a m  to 5 30 p m  Eastern Standard Time  You can also email us at  info dymax com  Please see the back cover of this user guide for worldwide contact information     Safety    WARNING  if you use this filling system without first reading and understanding the  information in this user guide  injury can result  To reduce the risk of injury  read and ensure you  understand the information in this user guide before assembling and operating a Tridak filling  system        General Saf
9. ety Considerations    All users of Tridak equipment should read and understand this user guide before assembling and using the  equipment     Specific Safety Considerations    Using Safe Operating Pressures    Pressurizing the components in the dispensing system beyond the maximum recommended pressure can  result in the rupturing of components and serious personal injury  To minimize the risk of rupturing  components and injury  do not exceed the maximum operating pressure of the components in your filling  system   See system specifications on page 17     Model 1050 Syringe Filling System User Guide    Preventing Injection Injury    Discharging fluids or compressed air with a dispensing tip against your skin can cause very serious injection  injury  To minimize the risk of injection injury  do not place the dispensing tip in contact with your skin     Personal Protective Equipment    Operators are recommended to wear any personal protective equipment specified by their company   s safety  policy for the materials used during filling  Personal protective equipment should be in place and used at all  times before pressurizing the system and when handling any potentially hazardous materials     Product Overview    Description of the Model 1050 Syringe Filling System    The Model 1050 syringe filling system is designed to quickly fill plunger style syringes  one at a time  quickly  and accurately from a material reservoir  The system can be used with a number of different materi
10. guards  and  safety devices are properly installed for operation     The system is energized when a compressed air supply is connected to the System Pressure Inlet     WARNING  Do not exceed 90 psi system pressure     The following steps must be completed in order to safely pressurize the system  If these steps are not  followed correctly  it is possible to create a situation that could result in a material spill through the Luer Tip     1  Ensure that the Fluid Path is correctly installed in the Luer Support and the Tube Support   2  Checkthat the Luer Clamp and the Tube Support are tightened down fully    3  Ensure the Luer Tip Cap is installed and tightened onto the Luer Tip    4  Disconnect the Material Reservoir Pressure Supply from the Material Reservoir Air Inlet   5  Connect a Compressed Air Supply  max 90 psi  to the System Pressure Inlet    6  Setthe Precision Air Regulator to O psi    7  Connectthe Material Reservoir Pressure Supply to the Material Reservoir Air Inlet    8  Setthe Precision Air Regulator to 10 psi starting pressure     9  Check for any material leaks occurring at the Luer Tip or at the Material Cartridge and depressurize  the system if any leaks are present     Depressurizing the System    1  Ensure the Luer Tip Cap is installed and tightened onto the Luer Tip   2  Setthe Precision Air Regulator to O psi   3  Disconnect the Material Reservoir Pressure Supply from the Material Reservoir Air Inlet     4  Disconnect the Compressed Air Supply from the 
11. ing   light blocking  black  polyethylene  Fluid tubing fittings   acetal   Fluid cartridge reservoirs   HPDPE    Fluid cartridge reservoir piston   HDPE    Model 1050 Syringe Filling System User Guide    Operating Specifications  Recommended compressed air supply pressure to air filter regulator   60 psi min  4 1 bar     Maximum pressure setting at air filter regulator   100 psi  6 9 bar     Compatible material viscosity range  1     60 000 cP    Reservoir Retainer  Tank Sizes    Cartridge retainers hold 20 and 32 o0z  550 and 900 mL  reservoirs  1 gallon  3 8 L  bulk feed reservoir option available  inquire with Tridak Customer Service    Air Precision Regulator Pressure Gauges    Pressure gauge installed from factory   0 to 100 psi  0 to 6 9 bar     Dimensions    Dimensions  L x W x H      23 6 in x 12 in x 25 in  60 cm x 30 48 cm x 63 50 cm     Model 1050 Syringe Filling System User Guide    Figure 12  Model 1050 Syringe Loader Dimensions       Tidak    2015 Tridak LLC     A Dymax Company  All rights reserved  All trademarks in this guide  except where noted  are the property of  or used under license by Tridak LLC or Dymax Corporation  U S A     Please note that most filling system applications are unique  Tridak does not warrant the fitness of the product for the intended application  Any warranty applicable to the product  its application and use is strictly limited to that contained  in Tridak s standard Conditions of Sale  Tridak recommends that any intended applicat
12. ion be evaluated and tested by the user to ensure that desired performance criteria are satisfied  Tridak is willing to assist users in their performance          testing and evaluation  Data sheets are available for pressure pots upon request  MANO74 2 17 2015  Dymax Corporation Dymax Oligomers  amp  Coatings Dymax UV Adhesives  amp  Equipment  Shanghai  Co Ltd Dymax Asia  H K   Limited   860 482 1010   info dymax com 860 626 7006   oligomers amp coatings dymax com  86 21 37285759   dymaxasia dymax com  852 2460 7038   dymaxasia dymax com  www dymax com   www tridak com www dymax oc com www dymax com cn www dymax com cn   Dymax Korea LLC Dymax Europe GmbH Dymax UV Adhesives  amp  Equipment  Shenzhen  Co Ltd Dymax Asia Pacific Pte  Ltd    82 2 784 3434   info_kr dymax com  49  0  611 962 7900   info_de dymax com  86 755 83485759   dymaxasia dymax com  65 6752 2887   info_ap dymax com    www dymax com kr www dymax de www dymax com cn www dymax ap com    
13. nnne nnne 7  Parts Included in the Model 1050 Syringe Filling System           Utilities Require dsena ED Een Ea er ra En nr ENEA E AERE reelle sled 7  Preparing the  System Ton USE aab EEN EEN 8  install  the Reservoir Supp ORE rr ae ite eet inde ene En En ae a aE lene 8  Install the  Material  RES  rvoite eR           8  Connect the Material Reservoir Pressure Supply Tube           cesccesscesssesssecssecsseceseecsneecseecseeessnessaeeseneceseeseueecaeessaeesseesenees 9  ODOR ATION Ec                                                                  Preparing the Cartridge  Loading the System  Pressurizing the System       Depressutizing the System   eret tet teet t Ri inedit egressi tact Lee euet yv stude odes ten Os 14  Set the Fill  Amount for the Syringe Size         ertet voe eben m cen ege ene 14  Primine the SySEelm     eere rae eter REOR EEG ARO Te presse EA C Rea ese E eau eeR IER TRIER HIR VERRE EHE XMIR NS gere tn  Prepare the Syringes     PINE GS VIB Ott tee  cese E DM MIENNE IUE  Mod  l 830 Valve Adjustments ise remo teni eei ie e Ehe iue ati N EN ESSES e C ED obese coven 16  Cleaning and Maintenance               5   5  eee ioi eiii E REESE e een eaa eI e e aoa I0 pe eoe nop e eoe e ooo KNEE e Ure essc 16  Systemi Gl  anifig uere exem ene anion Dmm e eer 16  ehr Ir Muiace iBsevcebatjeem uu                                                                                   EEE 17  Replacement Parts Accessories          5 tee trices ra EE Ee cord te sve en espe Re 
14. ontrol the air  pressure in the fluid reservoir  The air precision regulator includes     Model 1050 Syringe Filling System User Guide    a  Pressure gauge that displays the pressure in the fluid reservoir  A O  to 100 psi  0  to  6 9 bar  pressure gauge is installed on the air regulator     b  Pressure control knob that enables you to adjust the pressure of the air entering the  reservoir  5 45psi recommended for most applications     2  Compressed Air Line     The air line consists of blue polyurethane tubing designed for compressed air  use     3  Model 830 Valve     A disposable fluid path valve used to dispense material from the material  reservoir  This valve features suck back  allowing drip free dispensing from fill to fill     4  Fluid Path     The fill tube and fittings used to deliver fluid material from bulk cartridges to syringes  It  is constructed of black  light blocking polyethylene tubing compatible with many types of commercial  and medical fluids     5  Tube Support   Supports the disposable fluid path during dispensing and allows the valve pistons to  compress the fluid path as needed to control fluid flow and suck back     6  Reservoir Retainer or Reservoir Tank   The reservoir retainers and tanks hold fluid reservoirs   Reservoir retainers accept cartridge reservoirs  Reservoir tanks accept bottle and pail reservoirs     Figure 1  Main Components of the Model 1050 Syringe Filling System               Material Reservoir Support    Material Reservoir Pres
15. op of the screw hole in the left side of the system base     2  Using the screw and washer provided  place screw up with the washer through hole in base and  attach to reservoir support  Tighten the screw until the reservoir support is secure  Figure 3      Figure 3  Reservoir Support Installation          Install the Material Reservoir  1  Slide the Material Reservoir Retainer  Figure 4  D  over the top of the Reservoir Support  Figure 4  B      2  Position the Material Reservoir Retainer on the Reservoir Support so that the bottom of the Retainer  is approximately 2 inches above the top of the Back Plate     3  Using the Height Adjustment Handle  Figure 4  C   tighten the set screw until the Material Reservoir  Retainer does not move     Model 1050 Syringe Filling System User Guide EI    Connect the Material Reservoir Pressure Supply Tube    1  Connect the material reservoir   s Pressure Supply  Figure 4  F  to the Precision Air Regulator  Figure 4  G    2  Connect the opposite end of the Material Reservoir Pressure Supply to the Material Reservoir Air Inlet     NOTE  If your system is using a cartridge retainer  the Material Reservoir Air Inlet  Figure 4  A  is located  in the center of the cartridge retainer   s cap     Figure 4  Syringe Filler with 20 oz Cartridge Retainer  Rear View            B     Reservoir Support    A    Material Reservoir Air Inlet  C     Height Adjustment Handle    D   Reservoir Retainer  F     Material Reservoir Pressure Supply        G     Preci
16. sion Air Regulator E   Fluid Path    H     System Pressure Inlet    Model 1050 Syringe Filling System User Guide    Operation    Preparing the Cartridge    1  Place pre packaged  sealed cartridge upright on a flat  stable working surface  Figure 5      2  With the Nozzle up  remove the Colored Cap  and quickly insert the Mating Fitting from the  Disposable Fluid Path  Figure 6   Tighten firmly     3  Ensure the Fluid Path is sealed with a Luer Fitting and Cap before transporting or loading the  Cartridge into the Reservoir Retainer     NOTE  Low viscosity fluids may require Teflon  wrap on threads     Figure 5  Cartridge with Cap Installed Figure 6  Cartridge with Fluid Path Installed       Remove Cap       Nozzle Fluid Path    Mating Fitting    Model 1050 Syringe Filling System User Guide    Loading the System    Fill Material Reservoir    1  Remove the Reservoir Retainer Cover by removing the Star Nuts and Cover  Ensure the Retainer is  free and clear of any previously placed cartridges or packaging     2  Insert the Cartridge Fluid Path Assembly into the Reservoir Retainer   3  Guide the Fluid Path downward  passing through the bottom of the Reservoir   4  Press the Cartridge firmly into place until seated     5  Replace the Reservoir Retainer Cover and tighten evenly and securely with Star Nuts until the Cover  forms a solid seal around the Cartridge     If you experience any trouble  please contact Tridak Customer Service     Figure 7  Material Reservoir Exploded Diagram
17. sure Supply    Model 830 Dispensing Valve  Flow Control    Air Precision Regulator  Disposable Fluid Path       Compressed Air Line  Inlet  60 90 psi        Foot Switch         Tube Support Assembly    Valve Mounting Screw       Fill Stop    Model 1050 Syringe Filling System User Guide    Assembly and Setup    Unpacking and Inspecting Your Shipment    When your system arrives  inspect the boxes for damage and notify the shipper of box damage immediately     Open each box and check for equipment damage  If parts are damaged  notify the shipper and submit a claim  for the damaged parts  Contact Tridak so that new parts can be shipped to you immediately     Check that the parts included in your order match those listed below  If parts are missing  contact your local  Tridak representative or Tridak Customer Support to resolve the problem     Parts Included in the Model 1050 Syringe Filling System      Model 1050 with Foot Switch  1      Allen Key Kit  2      Airline Kit for Reservoir and Model 1050  3      Tube Assemblies     Luer Female  4      0 32  Bleed Wire with Pull Ring  5       Stopper Pin  for use with plunger less syringes   6     Rod Assembly  7      Reservoir  8      Model 1050 User Manual    Figure 2  Unpacking Diagram       Utilities Required    AIR  Clean  dry  non lubricated air operating pressure of 60     90 psi    8 Model 1050 Syringe Filling System User Guide    Preparing the System for Use    Install the Reservoir Support  1  Place the reservoir support on t
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
空気管漏れ発見器(KU-01)  - Fmuser.net    Whirlpool GZ7930XH User's Manual  Merci pour votre achat. Voici un mode d`emploi pour fixer votre  Betriebsanleitung Operating Instructions Instructions  Internet Update de PaintManager  Avision FB6280E  La traque aux surdoués - Enquêtes - Lefigaro  Stress and strain measures    Copyright © All rights reserved. 