        testo 550 · Digital manifold
         Contents
1.      Change parameter  select unit    Adjustable parameters   Representation Explanation   Cr Set temperature unit   bar  kPa  MPa  psi   Set unit of pressure     Pabs  Prel or psia    Depending on the selected unit of pressure   psig Switch between absolute and relative  pressure display     29 92 inHg  Set current absolute pressure  see table   1 013 bar  TEJAS Select measuring mode  see Selecting the    measuring mode  page 13       Settings will be applied following the final selection     Operating valve positioner    The digital manifold acts like a conventional two way manifold with  regard to the refrigerant path  The passages are opened by  opening the valves  The adjacent pressure is measured with valves  closed as well as with them open      gt  Open valve  Turn valve positioner anticlockwise    gt  Close valve  Turn valve positioner clockwise     6 1   6 1 1     6 Using the product    Only tighten valve positioner with your hand  Do not use any tools  when tightening as otherwise the thread may be damaged        Using the product    Preparing for measurement    Connecting the temperature sensor    O Sensors must be connected before the measuring  1 instrument is switched on  so that they are recognised by  the instrument     Surface temperature sensor    An NTC temperature sensor  accessory  must be connected for  measuring the pipe temperature and for automatic calculation of  superheating and subcooling     Deactivating the surface compensation factor for insert
2.     w    testo 550   Digital manifold    Instruction manual       1 Contents    Contents  Concili 3  Safety and the environment    ss 4  2 1  About this document                       4  2 2  Ensure SAM at 5  2 3  Protecting the environment    5  Specifications iii iaia 6  cli Velica 6  2  NG CMMMIGAL ala ccoo 6  Product GEOSCHID Muscari esse cen cannes sente es   s que 8  4 1  CONC is 8  FIS ESTOS cimas a e aaa 9  Using the produci 11  6 1  Preparing for measurement    11   6 1 1  Connecting the temperature sensor    11   6 1 2  Switching the Insirumentoni     lle 12   6 1 3  Selecting the measuring mode    13  6 2  Performing the measurement    14  Maintaining the PrOQUECE nsninnmiainaan andina la nheenesesmeaienne 16  Tips and assistance    sssssissinrenrrennrnennnnns 18  8 1  Questions and answers                       18  8 2  Measurement parameters                        18  0 9       TFOT NODOMS iii 19  8 4  Accessories and spare parts                          19    2 Safety and the environment    Safety and the environment    About this document    Use     gt  Please read this documentation through carefully and  familiarize yourself with the product before putting it to use  Pay  particular attention to the safety instructions and warning advice  in order to prevent injuries and damage to the products      gt  Keep this document to hand so that you can refer to it when  necessary      gt  Hand this documentation on to any subsequent users of the  product     Symbols 
3.  R407C  R408A   R409A  R410A  R411A  R413A  R414B   R416A  R417A  R420A  R421A  R421B   R422A  R422B  R422D  R424A  R427a   R434A  R437A  R438A  R502  R503  R507   R600  R600a  R718  H20   R744  only in  permissible measuring range up to 50 bar    R1234yf  Display  T8     Measurable media  All media that are stored  in the testo 550  Not measurable  Ammonia    R717  and other refrigerants which contain   ammonia    Operating temperature   10 to 50   C   14 to 122   F    Storage temperature   20 to 60   C    4 to 140   F    Material  ABS PA TPU  Dimensions  265 x 135 x 75 mm  Weight  approx  1000 g  without batteries     Current source  Rechargeable  batteries batteries 4x 1 5 V  type  AA mignon LR6    Battery life  approx  150 h  display light off   Type  Illuminated LCD   Updating of readings  1s   Response time  0 5 s   EC Directive  2004 108 EC    Duration  2 years    Warranty conditions  see website  www testo com warranty    4 Product description    4  4 1     Product description    Overview    Display and control elements       1 Mini DIN probe socket for NTC temperature probe  with socket  cover    2 Foldable suspension device  on rear   3 Display  Instrument status icons        Select measuring mode  see   Pay    4 Battery compartment  It is not possible to charge rechargeable  batteries in the instrument     5 First steps    5 Control keys     Key Function    Set  Set units    R  Start  Stop   Select refrigerant  Start stop   Tightness  test    Mode  Switching measur
4. and writing standards  Representation   Explanation    A Warning advice  risk level according to the  signal word     Warning  Serious physical injury may occur     Caution  Slight physical injury or damage to  the equipment may occur      gt  Implement the specified precautionary  measures     Note  Basic or further information     alee    Action  more steps  the sequence must be  followed     gt  db Action  a step or an optional step      oa  Result of an action     Menu Elements of the instrument  the instrument  display or the program interface      OK  Control keys of the instrument or buttons of  the program interface     sala Functions paths within a menu     Example entries    2 2     2 3     2 Safety and the environment    Ensure safety     gt     Do not operate the instrument if there are signs of damage at  the housing  mains unit or feed lines     Do not perform contact measurements on non insulated  live  parts     Do not store the product together with solvents  Do not use any  desiccants     Carry out only the maintenance and repair work on this  instrument that is described in the documentation  Follow the  prescribed steps exactly  Use only original spare parts from  Testo     The objects to be measured or the measurement environment  may also pose risks  Note the safety regulations valid in your  area when performing the measurements     If the measuring instrument falls or another comparable  mechanical load occurs  the pipe sections of the refrigerant  hos
5. e  1 to Ev is displayed after the complete evaporation the  condensation temperature tc Co is displayed after the  complete condensation     The measured temperature must be assigned to the  superheating or the subcooling side  ton  lt    gt  tcu    Depending on this assignment  ton T1 or Aton SH or  tu T2 or Atcu SC is shown depending on the selected  display     14    6 Using the product      Reading and display illumination flash   e 1 bar before reaching the critical pressure of the refrigerant   e upon exceeding the max  permissible pressure of 50 bar     Key functions   gt   A  or W   Change the reading display     Possible display combinations        Evaporation pressure Condensation pressure  Refrigerant evaporation Refrigerant condensation  temperature to Ev temperature tc Co    or  only with connected temperature probe     Evaporation pressure Condensation pressure  Measured temperature tn T1   Measured temperature t   T2    or  only with connected temperature probe     Evaporation pressure Condensation pressure  Superheating Atcr SH  Subcooling At  SC    With two connected NTC probes  At is also shown      gt   Mean Min Max   Record readings  display min  max  readings   mean values  since switching on      Tightness test pressure drop test      Systems can be tested for tightness with the   1 temperature compensated tightness test  The system  pressure and the ambient temperature are measured  over a defined period for this  A temperature probe can  be connected t
6. er damage inside the measuring  instrument  which may not be detectable from outside      gt  For your own safety you should return the measuring  instrument to the Testo Service for technical inspection     You should therefore always replace the refrigerant hoses with  new ones after the measuring instrument has dropped down or  after any comparable mechanical loading        Setting the refrigerant  1  Press  R  Start Stop        This opens the refrigerant menu and the currently selected  refrigerant flashes     2  Setting the refrigerant     12    6 1 3     6 Using the product    Key functions       Representation Explanation   A  or V  Changing the refrigerant   R  Start Stop  Confirm the setting and exit the refrigerant    menu     Available refrigerants    Representation Explanation   R    Refrigerant number of refrigerant acc  to  ISO 817   i per Special Testo designation for certain    refrigerants  T8   T1234yf   7 no refrigerant selected     Example  Setting refrigerant R401B  1  Press  A  or  V  several times  until R401B flashes   2  Press  R  Start Stop  to confirm the setting     Quitting the refrigerant selection     gt  Press  R  Start Stop  or automatically after 30 s  if no other key  has been pressed     Selecting the measuring mode  1  Press  Set  several times    2  Select function with  A  or  V     3  Save setting  press  Sef       Measuring mode is dsplayed     Display Mode   Function      Refrigeration  Normal functionality of the digital manifold  sy
7. es may break  The valve positioners may also be damaged   whereby further damage to the interior of the measuring  instrument may occur that cannot be identified from the outside   The refrigerant hoses must therefore be replaced with new   undamaged refrigerant hoses every time the measuring  instrument falls or following any other comparable mechanical  load  Send the measuring instrument to Testo Customer  Service for a technical check for your own safety     Electrostatic charging can destroy the device  Integrate all the  components  system  manifold s valve block  refrigerant bottle  etc   into the potential equalisation  earthing   Please see the   safety instructions for the system and the refrigerant used     Protecting the environment     gt      gt     Dispose of faulty rechargeable batteries spent batteries in  accordance with the valid legal specifications     At the end of its useful life  send the product to the separate  collection for electric and electronic devices  observe local  regulations  or return the product to Testo for disposal     Refrigerant gases can harm the environment  Please note the  applicable environmental regulations     3 Specifications    3 2     Specifications    Use    The testo 550 is a digital manifold for maintenance and servicing  work at refrigeration systems and heat pumps  It must only be used  by qualified authorized personnel     The testo 550 replaces mechanical manifolds  thermometers and  pressure temperature tables by mea
8. hat measures the ambient temperature  for this  recommendation  NTC air probe  art  no  0613  1712   Information about the temperature compensated  differential pressure and about the temperature at the  beginning end of the test exists as a result  If no  temperature probe is connected  the tightness test can  be performed without temperature compensation     Y The steps described in the chapter  Preparing for  measurement  have been completed    1  Press  Mode   leakage test view       Leakage test view is opened  AP is displayed    2  Start the leakage test  Press  R  Start Stop     3  End the leakage test  Press  R  Start Stop      15    7 Maintaining the product    16      Result is displayed   4  Confirm message  Press  Mode        You automatically jump to the evacuation vacuum display  menu     Evacuation vacuum display       The measurement is performed on the low pressure    i Side    5  Press  Mode       Result is displayed on the low pressure side   6  Press  Mode       The measuring mode is displayed     Maintaining the product    Cleaning the instrument     gt  Ifthe housing of the instrument is dirty  clean it with a damp  cloth     Do not use any aggressive cleaning agents or solvents  Weak  household cleaning agents and soap suds may be used     Keeping connections clean     gt  Keep screw connections clean and free of grease and other  deposits  clean with a moist cloth as required     Removing oil residues     gt  Carefully blow out oil residues in valve bl
9. ing mode     Min Max Mean    Display min  max  mean values     A  Up key  Change display view    p 0  Pressure zeroing   xt Light key  Switch display light on off   V  Down key  Change display view  10  Switching the instrument on off    6 Sight glass for refrigerant flow   7 2x valve positioner   8 3 x hose parkers for refrigerant hoses  9    3 x connections 7 16  UNF  brass   Left right  Low pressure high pressure  for refrigerant hoses with  quick connect fitting  passage can be locked via valve  positioner  Centre  for refrigerant bottles  for example  with  sealing cap     First steps    Inserting batteries rechargeable batteries    1  Fold out the suspension device and open the battery  compartment  clip lock      2  Insert batteries  included in delivery  or rechargeable batteries   4x 1 5 V  type AA Mignon LR6  in the battery compartment   Observe the polarity     Close the battery compartment     When not in use for long period  Remove  batteries rechargeable batteries     Completely charge rechargeable batteries before using the  instrument     mie   me         5 First steps    10    Switching the instrument on     gt  Press  0      Initialization phase    e All display segments are lit  length of time  2 s      Measurement view is opened     Performing settings  1  Press  Set        The configuration menu is opened and the adjustable  parameter flashes     2  Set parameters   Key functions  Representation   A  or  VI    Set  Select units parameters    Explanation  
10. ion and  air temperature sensor    A surface compensation factor has been set in the measuring  instrument to reduce the measuring errors in the main field of  applications  This reduces measuring errors when using surface  temperature sensors     If the measuring instrument testo 550 is used in combination with  insertion or air temperature sensors  accessories   this factor must  be deactivated      gt  Press and hold the keys SET   MODE together and switch on  the measuring instrument  0      The instrument shows the message Fact off        The surface compensation factor becomes active every  1 time the measuring instrument is switched on     11    6 Using the product    6 1 2  Switching the instrument on   gt  Press  0      Zeroing the pressure sensors  Zero the pressure sensors before every measurement     Y All connections must be pressureless  ambient pressure       gt  Press key  P 0  and execute Zeroing     Connecting the refrigerant hoses       Before each measurement check whether the refrigerant  1 hoses are in flawless condition       The valve actuators are closed     1  Connect the refrigerant hoses for low pressure side  blue  and  high pressure side  red  to the measuring instrument     2  Connect the refrigerant hoses to the system     The measuring instrument dropping down or any other comparable  mechanical load can cause breakage of the pipe pieces in the  refrigerant hoses  The valve actuators may also suffer damage   which in turn could result in furth
11. ns of its functions  Pressures  and temperatures can be loaded  adjusted  tested and monitored     The testo 550 is compatible with most non corrosive refrigerants   water and glycol  The testo 550 is not compatible with refrigerants  that contain ammonia     The product must not be used in areas at risk of explosion     Technical data    Characteristic Values   Parameters Pressure  kPa   MPa   bar   psi  Temperature    C   F K   Sensor Pressure  2 x pressure sensor  temperature   2xNTC   Meas  cycle 0 75 S   Measurement Quantity  4   channels   Interfaces Pressure connections  3 x 7 16  UNF    NTC measurement    Measuring ranges   Pressure measuring range HP LP    1 to 50 bar  rel   14 7 to 725 psi  rel    100 to 5000 kPa  rel  0 1 to 5 MPa  rel     Temperature measuring range    50 to  150   C  58 to 302   F    Humidity application   10 to 90   RH    range  Overload 60 bar  6000 kPa  6 MPa  870 psi  Resolution Pressure resolution  0 01 bar 0 1 psi     1 kPa 0 001 MPa  Temperature resolution  0 1   C 0 1   F    Characteristic    Accuracy  nominal  temperature  22   C 71 6   F     No  of refrigerants    Selectable  refrigerants    Measurable media    Ambient conditions    Housing    Power supply    Display    Directives   standards and tests    Warranty    3 Specifications    Values  Pressure   0 75   of final value   1 digit   Temperature   40   150  C    0 5 K   1 digit     40    No refrigerant  R12  R22  R123  R134a   R290  R401A  R401B  R402A  R402B   R404A  R406A  R407A 
12. ock using compressed  air     Ensuring the measuring accuracy    Testo Customer Service would be glad to further assist you if you  so wish      gt  Check instrument regularly for leaks  recommended  annually    Keep to the permissible pressure range      gt  Calibrate instrument regularly  recommended  annually      7 Maintaining the product    Changing batteries rechargeable batteries    Y Instrument is switched off        1  Fold out the suspension device  loosen the clip and remove the  cover of the battery compartment     2  Remove empty batteries rechargeable batteries and insert new  batteries rechargeable batteries  4x 1 5 V  type AA  Mignon   LR6  in the battery compartment  Observe the polarity     3  Seton and close cover of the battery compartment  clip must  engage      4  Switch the instrument on     Changing the valve or valve positioner handle    Change of the valve positioners and valves by the customer is not  permissible         gt  Send the measuring instrument to the Testo Customer Service     17    8 Tips and assistance    Possible causes solution    8 Tips and assistance  8 1  Questions and answers  Question  laes    The instrument switches  off automatically     uuuu lights up instead of  the parameter display    0000 lights up instead of  the parameter display    8 2     Name          tcu 12    18    Batteries are almost empty    gt  Change batteries     Residual capacity of the batteries is  too low      gt  Change batteries     The permissible measu
13. ring range has  been undershot      gt  Keep to the permitted measuring  range     The permissible measuring range has  been exceeded      gt  Keep to the permitted measuring  range     Measurement parameters    Description   Superheating  evaporation pressure  Subcooling  condensation pressure  Refrigerant evaporation temperature  Refrigerant condensation temperature  Measured temperature  evaporation    Measured temperature  condensation    8 3     8 4     8 Tips and assistance    Error reports    Question Possible causes solution         iS lit up instead of Sensor or cable defective  measurement parameter     gt  Please contact your dealer or  display    Testo Customer Service  Display EEP FAIL Eeprom defective     gt  Please contact your dealer or  Testo Customer Service       Accessories and spare parts    Description Article no     Clamp probe for temperature measurement  0613 5505  at pipes    Pipe wrap probe with Velcro tape for pipe 0613 4611  diameters of up to max  75 mm  Tmax      75   C  NTC   Watertight NTC surface probe 0613 1912  Precise  robust NTC air probe 0613 1712  Transport case for measuring instrument  0516 5505    probe and hoses    For a complete list of all accessories and spare parts  please refer  to the product catalogues and brochures or look up our website at   www testo com    If you have any questions  please contact your dealer or Testo  Customer Service  The contact details can be found on the back of  this document or on the Internet at w
14. stem    Y Heat pump  Normal functionality of the digital manifold    VES Automatic  If the automatic mode is activated  the  mode testo 550 digital manifold automatically  changes the display of the high and low  pressure  This automatic change occurs  when the pressure on the low pressure  side is 1 bar higher than the pressure on  the high pressure side  During the  change  Load  2 s  is shown in the       13    6 Using the product    Function  display     Display    This mode is especially suited to air  conditioning systems which cool and  heat        6 2  Performing the measurement    Risk of injury caused by refrigerant that is at high pressure   hot  cold  or poisonous     Wear safety goggles and protective gloves     Before pressurizing the measuring instrument  Always fasten  the measuring instrument at the suspension device in order to  prevent it from falling  risk of breakage     Check if the refrigerant hoses are intact and connected  correctly before each measurement  Do not use a tool to  connect the hoses  Only tighten the hoses by hand  max   torque 5 0 Nm 3 7 ft lb      Maintain permissible measuring range  0 to 50 bar   Pay  particular attention with systems with refrigerant R744  as  these are often operated with higher pressures        Measuring    Y The steps described in the chapter  Preparing for  measurement  have been completed     Pressurize the measuring instrument   Read off readings     2    With zeotropic refrigerants  the evaporation temperatur
15. ww testo com service   contact      19       0970 5501 en 06 V01 16    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
PowerLogic Power Meter PM5350 - English  User Manual - Cleaningshop.com.au  Philips 220E1SB1/01  Simpli Home AXWSH006 Instructions / Assembly  Samsung GT-S5380D Užívateľská príručka  Tecumseh AE4425Z-FZ1A Performance Data Sheet  Copie de NOTICE BALANCE SATRUE N3670 OK  154411 revB 12GHz revA.fm  ST Lab U-510      Copyright © All rights reserved. 