Home

instructions for safe operations lm3000

image

Contents

1. C 14 1 Drawings Refer to Certificate Annexe 142 Associated Sira Reports and Certificate History R22395A 00 The release of the prime certificate Project Number 22395 DR Stubbings BA MIET Certification Manager bi ee ay ele cin ee pel na This certificate and its schedules may only be reprod in its entirety and wi t change i Sira Certification Service reproduced in its entirety and without change Sira Certification Service fasi ofS Rake Lane Eccleston Chester CH4 9JN England Rake Lane Eccleston Chester CH4 9JN England Ta 44 0 1244 670900 Page 2 of 3 Tel 44 0 1244 670900 Form 9400 Issue 1 Fax 44 0 1244 681330 1 ER 44 0 1244 681330 Email jinfo siracertification com Web www siracertification com Web i ifi n CorDEX LaserMETER 3000XP Explosion Proof Laser Distance Meter IECEx CERTIFICATE OF CONFORMITY RUGGED sira CERTIFICATION SCHEDULE EC TYPE EXAMINATION CERTIFICATE Sira 10ATEX1283X IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres Issue 0 for rules and details of the IECEx Scheme visit www iecex com 15 SPECIAL CONDITIONS FOR SAFE USE denoted by X after the certificate number 15 1 In accordance with clause 5 1 of EN 60079 1 the critical dimensions of the flamepaths are i Main body battery pack Status Current Front lens main bod Date of Issue 2010 12 08 Page 1 of 3 15 2 This equipment shall only b
2. atmospheres Part 0 General requirements Edition 4 0 IEC 60079 1 2007 04 Explosive atmospheres Part 1 Equipment protection by flameproof enclosures d Edition 6 This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above TEST amp ASSESSMENT REPORTS A sample s of the equipment listed has successfully met the examination and test requirements as recorded in Test Report GB SIR ExTR10 0275 00 Quality Assessment Report GB SIR QAR10 0010 00 IECEx Certificate of Conformity Certificate No IECEx SIR 10 0133X Date of Issue 2010 12 08 Issue No 0 Page 3 of 3 Schedule EQUIPMENT Equipment and systems covered by this certificate are as follows The LM3000XP is a flameproof enclosure containing a laser distance meter The device comprises a main enclosure with a bolt on external battery pack and a non metallic overmoulding For a full description refer to the Annexe CONDITIONS OF CERTIFICATION YES as shown below 1 In accordance with clause 5 1 of IEC 60079 1 the critical dimensions of the flamepaths are Flamepath Maximum Gap mm Minimum Gap mm Main body cover 0 04 11 0 Main body battery pack 0 04 10 0 Front lens main body 0 1 13 8 Top lens main body 01 13 8 2 This equipment shall only be used where there is a low risk of mechanical impact The equipment is manufactured in aluminium alloy in Group appl
3. CorDEX LM3000 EXPLOSION PROOF LASER DISTANCE METER an 1 RUGGED WwWwWw cord ex com CorDEX LaserMETER 3000XP Explosion Proof Laser Distance Meter CONTENTS Read This First 3 Liability 3 Trademark Information 3 Product Information 3 Special Conditions for Safe Use 4 Operational Cautions 5 Certification 6 EC Declaration of Conformity ATEX Certificate 8 IECEx Certificate 11 RUGGED READ THIS FIRST The LM3000 is an explosion proof laser measurement device suitable for use in hazardous areas Ex zones potentially explosive environments Read and understand all Warnings and Cautions before using this product Liability The technical specification of the camera complies with relevant European Ex standards EN 60079 0 and EN60079 1 The user is solely responsible for ensuring the equipment is suitable for the intended purpose and environments CorDEX Instruments will not be liable for any injury or damage resulting from unauthorized adjustments to or dismantling of the camera or for use with inappropriate applications or environments Trademark Information Microsoft and Windows are U S registered trademarks of Microsoft Corporation Pentium is a registered trademark of Intel Corporation Macintosh is a trademark of Apple Computer Inc SD is a trademark Other names and products may be trademarks or registered trademarks of their respective owners Product Inform
4. CorDEX oe Certificate No Sira O8ATEX1293X EGE SHR SS Eee Lane Industrial Certificate Type C Pn om Declaration No SO 4 Ex EC Type Examination Certificate Siral0ATEX1283X WN M272 6 cel EX 0 lG Ja EC Declaration of Conformity Ambient Temperature Tamb 20 C to 50 C in accordance with EEC ATEX Directive 94 9 EC Power Supply Battery Pack CDX2341 007 We CorDEX Instruments Ltd Hereby declare that the products described below Product Laser Distance Meter Model LM 3000XP are in conformity with the essential health and safety requirements of Council Directive 94 9 EC relating to equipment intended for use in potentially explosive atmospheres ATEX Directive I II M2 2 G Ex d I IIC T4 Ta 20 C to 50 C equipment by the application of the following Standards Electrical apparatus for explosive gas atmospheres General EN 60079 0 2006 requirements EN 60079 1 2007 Explosive atmospheres Equipment protection by flameproof enclosures d and are subject to the procedure set out in Annex VII of Directive 94 9 EC and these procedures are in conformity with the requirements of EN 13980 2002 under the supervision of Notified Body Number 0518 SIRA Certification Service Rake Lane Eccleston Chester CH4 9JN England It is ensured through internal measures that the products conform at all times to the requirements of the current EEC Directives and relevant standards Signature PR BGG Auth
5. ation Product design and specifications are subject to change without notice This includes primary specifications software software drivers and user s manual The User Manual is a general reference guide for the product The manufacturer assumes no liability for any errors or discrepancies in the user manual CorDEX LaserMETER 3000XP Explosion Proof Laser Distance Meter SPECIAL CONDITIONS FOR SAFE USE as defined by clause 29 2 1 of EN 60079 0 The conditions referenced in this section relate specifically to hazardous area applications and must be followed In accordance with clause 5 1 of EN 60079 1 the critical dimensions of the flamepaths are Flamepath Maximum Gap Minimum L mm mm Main body 0 04 11 0 cover Main body 0 04 10 0 battery pack Front Lens 0 1 151 8 main body Top lens 01 1318 main body e This equipment must only be used where there is a low risk of mechanical impact e The equipment is manufactured in aluminium alloy in Group applications this equipment must not be utilised where there is a risk of thermite reaction frictional ignition e The LaserMETER 3000XP must only be recharged in a non hazardous area Extreme Care should be taken to ensure that no damage occurs to the flamepath between battery and casing Ensure dowel location pins are engaged fully before tightening locking screws RUGGED LaserMETER 3000XP incorporates a protected battery
6. ce by means of a steel 7 This equipment and any acceptable variation thereto is specified in the schedule to this certificate and retaining plate which in turn is secured by four M3 x 10 mm hexagonal socket cap head screws the the documents therein referred to heads of these screws being protected by their location behind the external overmoulding 8 Sira Certification Service notified body number 0518 in accordance with Article 9 of Directive 94 9 EC The top part of the main enclosure is provided with a cover the joint between the cover and main body of 23 March 1994 certifies that this equipment has been found to comply with the Essential Health and forming a flanged flamepath The cover is secured to the main body by nine M3 x 8 mm hexagonal Safety Requirements relating to the design and construction of equipment intended for use in socket cap head screws the heads of these screws being protected by their location in appropriate potentially explosive atmospheres given in Annex II to the Directive counter bored holes The top of the cover is machined to allow the installation of a toughened glass a i n LCD viewing window the joint between the glass window and the main body forming a spigotted The examination and test results are recorded in the confidential reports listed in Section 14 2 flamepath The window is secured in place by means of a steel retaining plate which in turn is secured 9 Compliance with the Essential Health and Safety Requirement
7. certificate and schedule may only be reproduced in full 2 This certificate is not transferable and remains the property of the issuing body 3 The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website Certificate issued by RA Certification Service Rake Lane Eccleston i r Chester United Kingdom CERTIFICATION CorDEX LaserMETER 3000XP Explosion Proof Laser Distance Meter RUGGED IECEx Certificate of Conformity Certificate No IECEx SIR 10 0133X Date of Issue 2010 12 08 Issue No 0 Page 2 of 3 Manufacturer CorDEX Instruments Ltd Unit 6 Farfield Main Road Wykeham Scarborough YO13 9QD United Kingdom Manufacturing location s This certificate is issued as verification that a sample s representative of production was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer s quality system relating to the Ex products covered by this certificate was assessed and found to comply with the IECEx Quality system requirements This certificate is granted subject to the conditions as set out in IECEx Scheme Rules IECEx 02 and Operational Documents as amended STANDARDS The electrical apparatus and any acceptable variations to It specified in the schedule of this certificate and the identified documents was found to comply with the following standards IEC 60079 0 2004 Electrical apparatus for explosive gas
8. e used where there is a low risk of mechanical impact The equipment is manufactured in aluminium alloy in Group I applications this equipment must not be utilised where Applicant CorDEX Instruments Ltd there is a risk of thermite reaction frictional ignition Unit 6 Farfield 16 ESSENTIAL HEALTH AND SAFETY REQUIREMENTS OF ANNEX II EHSRs rechne The relevant EHSRs that are not addressed by the standards listed in this certificate have been Scarborough identified and individually assessed in the reports listed in Section 14 2 YO13 90D United Kingdom 17 CONDITIONS OF CERTIFICATION 17 1 The use of this certificate is subject to the Regulations Applicable to Holders of Sira Certificates 17 2 Holders of EC type examination certificates are required to comply with the production control requirements defined in Article 8 of directive 94 9 EC e Poe Laser Distance Meter LM3000XP Type of Protection Flameproof Marking Ex d VIIC T4 Ta 20 C to 50 C Approved for issue on behalf of the JECEx DR Stubbings BA MIET Certification Body Position Certification Manager Signature for printed version c Date DZoio 12 0 This certificate and its schedules may only be reproduced in its entirety and without change Page 3 of 3 Form 9400 Issuel Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England Tel 44 0 1244 670900 Fax 44 0 1244 681330 Email info siracertification com Web wow siracertification com 1 This
9. ications this equipment must not be utilised where there is a risk of thermite reaction frictional ignition Annexe ECEx SIR 10 0133X Issue 0 Annexe pdf Copyright 2014 CorDEX Instruments Limited All other brand and product names are trademarks of CorDEX Instruments Limited Document Number ID 2105 Revision A
10. orised Person Position Director on behalf of CorDEX Instruments Ltd Date 07 10 2014 Product Serial number Better Better_Work CorDEX 03_CorDEX_Products CorDEX_Products_LM3000 CorDEX_ECDeclaration EC Declaration of Conformity LM3000XP Rev D docx RUGGED CorDEX LaserMETER 3000XP Explosion Proof Laser Distance Meter ATEX CERTIFICATE sira CERTIFICATION sira CERTIFICATION SCHEDULE 1 EC TYPE EXAMINATION CERTIFICATE 2 Equipment intended for use in Potentially Explosive Atmospheres Directive 94 9 EC EC TVPE EXAMINATION CERTIFICATE Sire a 3 Certificate Number Sira 10ATEX1283X Issue O 4 Equipment Laser Distance Meter LM3000XP 13 DESCRIPTION OF EQUIPMENT The LM3000XP is a flameproof enclosure containing a laser distance meter The device comprises a 5 Applicant CorDEX Instruments Limited main enclosure with a bolt on external battery pack and a non metallic overmoulding 6 Address ps ee The main enclosure comprises three main parts the body the battery pack and the cover These are ain Road all cast in aluminium 6082T6 and subsequently machined The main body incorporates a void provided Wykeham h for the installation of the laser distance meter The end of the main body is machined to allow the Scarboroug installation of a rectangular toughened glass laser window the joint between the glass window and the YO13 9QD main body forming a spigotted flamepath The window is secured in pla
11. s with the exception of those listed in the by four M3 x 10 mm hexagonal socket cap head screws the heads of these screws being protected by schedule to this certificate has been assured by compliance with the following documents their location behind the external overmoulding IEC 60079 0 2004 Ed 4 IEC 60079 1 2007 Ed 6 Located on the side of the main enclosure is a detachable battery pack The battery pack comprises an neo KB aluminium housing contain two rechargeable AAA size batteries and associated circuitry The joint 10 If the sign X is placed after the certificate number it indicates that the equipment is subject to special between the battery pack and the front cover forms a flanged flamepath The battery cover is secured conditions for safe use specified in the schedule to this certificate by six M4 x 12 mm hexagonal socket cap head screws the heads of these screws being protected by 11 This EC type examination certificate relates only to the design and construction of the specified their location in appropriate counter bored holes ee AS further requirements of this Directive apply to the manufacture and supply of All fasteners are stainless steel to ISO 4762 grade A2 70 is equipment SNP The assembly is provided externally with a permanent non metallic anti static protective overmoulded 12 The marking of the equipment shall include the following case 14 DESCRIPTIVE DOCUMENTS Es I II M2 2 G z Ex d I IIC T4 Ta 20 C to 50
12. system with a replaceable fuse This Fuse is only to be replaced with CorDEX Instruments Type CDX2341 120 fuse Failure to do so will void the certification Ensure that the LaserMETER 3000XP battery pack is Secured using the screws provided If the screws are lost only replace with screws of the correct size and type If in doubt contact your nearest CorDEX Instruments representative The LaserMETER 3000XP is manufactured from aluminium alloy with less than 7 magnesium by weight and incorporates toughened glass windows This should be taken into account when considering the end use application The LaserMETER 3000XP cannot be maintained in the fleld and must be returned to the manufacturer should repair or maintenance be required OPERATIONAL CAUTIONS The cautions contained in this section do not relate specifically to safe use in hazardous area applications but should be followed to help prevent damage to the camera or personnel Do not fire the Laser close to anyone s eyes This might cause damage to the person s eyesight e Keep out of the reach of children e A Laser is a precision instrument Do not drop it strike it or use excessive force when handling the Laser This might cause damage to the device Do not wrap the Laser or place in cloth blankets CorDEX LaserMETER 3000XP Explosion Proof Laser Distance Meter CERTIFICATION EC DECLARATION OF CONFORMITY Model LaserMETER 3000XP