Home
user manual DJ LCD ID
Contents
1. Press 1 Input 4 digits code number Refer to the table Press Input 8002 then input Setup Code or Admin Code Language code number 8113 Russian 8101 English 8102 French 8103 Spanish 8104 Italian 8105 German 8107 Portuguese 8108 S Chinese 8109 T Chinese 8110 Greek 8111 Turkish 8114 Slovakia 8115 Hungary 8116 Czech When the door station output a long sound Dl that means UI 8106 Dutch 8112 Polish updating Is finished 12 Search online door stations and monitors Online Search is a very useful function that can help the installer to easily check the connectivity of all the Monitors Please note Online does not mean via the internet Please refer to the followings Check online door stations 5 Online Devices Redial Installer Setup DS1 Online DS2 Fail DS3 Fail DS4 Fail Setup Tools Card Memory Online Monitors Exits Online Devices Voltage Measure In Debug State press 1 Press 5 key Check door stations key connection status Check online monitors 4 Online Monitors Redial Installer Setup Setup Tools Card Memory l Pres NO Online Monitors Exits toselect 5 Online Devices Search Range Voltage Measure Back Back Save In Debug State press 1 Press 4 key Input 2 digits key mo
2. Display Mode Press No o Clock oie Setup Code About Back Default lt Press Input 8002 then input Press 2 to enter tone Input 2 digits number Setup Code or Admin select item then press to save Code 88888888 or 66666666 by the setting default 7 Change Installer Code administrator password The Installer Code is the password to access the door station debug State The default Installer Code is 66666666 Note that if the Default Set have been activated the Installer Code will be set to default value ID Code 1 Unlock Timing 05 Unlock Output 0 Card Memory 0 Doorplate Mode Audio Options Parameters Installer Code Default Redial Installer Setup Installer Setup Setup Toole Card Memory Press1 9 Online Monitors to select WO MO ND UA WN RB Exits Online Devices Voltage Measure Back In Debug State press 1 press 1 press 8 4 key 8 Installer Code Input a new Installer Code and then press key to confirm 8 How to use code unlock function Please refer to the following operations O00 OO OO 000 When the Door Station isin Input 4 digits Unlock Code lf verified correctly standby Press directly door open 9 Change Unlcok Code lf door sta
3. Card Card numbs 15977131 Show The Card Save 3 Delete By M code O1 Updated Card information 4 Cards Information Enter Card Information page and the screen will display the authorized User Cards count and card read access Card Count 1000 events count Format Enter Card Format page a password will be asked input 8 digits installer password 66666666 by default then press key to save format operation eG eave is activated all card information will be cleared Please Input Password 11 Change Door Station Language It s convenient to change the user interface for DPC D218 Just put the config files to the SD card and by means of the digital keypad of door station only 30 seconds is needed to update Insert SD card SD Card Slot Fa L1 L2 coco contained config files into the SD card slot where is at the back of the door station Refer to the right diagram Step 2 lf door station runs as Debug State you can press 1 to activate Tools Menu select 2 to enter setup page then select 1 item If it runs as Normal State follow these steps Tone Select 03 Tone Volume 03 Unlock Code 1111 Display Mode Clock Setup Code About Default Back 1 Language Code Number Save
4. 8 then input the Debug State menu is launched standby press key Admin Code 66666666 by default Press 2 key to exit out the debug state 3 About Debug Tools During working at Debug State press 1 to enter tools page Debug Tools overviews is shown as below v i Tools Installer Setup Redial Setup Tools Card Memory Pres NO Online Monitors Exits to select Online Devices Voltage Measure Back Table 1 1 Installer Setup 2 Setup 3 Card Manage 4 Online Monitors 5 Online Devices 6 Voltage Measure ID Code 1 Unlock Timing 05 Unlock Output 0 Card Memory 0 Doorplate Mode Audio Options Parameters Installer Code Default CO ON OOF WN Language 1 Tone Select 03 Tone Volume 08 Unlock Code 1111 Display Mode Clock Setup Code About Default OONDOAKR WD Add Card Delete By Card Delete By M code Cards Information Format oF wh To search the online monitors input the monitor code number to search To search the online door stations Max 4 door station can be searched To check the voltage of the monitor note that the monitor must be online Basic Tools Detail Table 2 Installer Setup Item ID Code Unlock Timing Unlock Output Card Manage Doorplate Mode Audio Options Parameters Installer C
5. DJ LCD ID Door Station User Manual 1 Parts and Functions Camera Lens Night View LED Speaker s Adjustable Camera LCD Screen 350 mm ID Card Window Connectiong Port Digital Keypad e ED Microphone 128 mm With rainy cover SD Card Slot Lt L2 CN LK OOOOOO agate TR T R WWZ yy 32 1 000000000 J KMB JP LK Bus e 12V 12VDC power output LK GND power ground LK COM common contact of the Relay e NO normally open contact of the Relay refer to 2 wire technical guide for Lock connection detail information EB Exit button connection port EB Exit button connection port e JP LK For electronic lock safety type setting refer to Door Station Lock Connections T R USB RS485 communication terminal negative T R USB RS485 communication terminal positive Bus L1 L2 non polarity bus line 3 Door Station Mounting Camera Drill a hole and attach the The view for rainy Adjust the camera angle and attach the rainy cover to it cover after mounted metal to the panel and wire correctly Attach screws to fix the Attach the unit to the rainy Attach the baffle to protect metal box cover correctly the unit from dropping The last view for al
6. V camera Range from 6s to 600s Wait Timing To show the calling wait time Rang from 10s to 600s 30s Talk Timing E sn the limitation time of talking Range from 10s 90s To enable Indoor Monitor under monitoring state can Monitor amp Speack speak to Door Station at same time If set to 1 talk enabled set to 0 disabled To enable Monitors under monitoring state can open the door at the same time lf set to 0 unlock function Monitor amp Unlock fis disabled Set to 1 unlock is enable Set to 2 unlock 1 is enable and close at once Set to 3 unlock is enable and close in 5s To show ring times when door station calls monitor 4 Ring Numbers options for choice If set to 0 ring once If set to 1 ring 1 twice If set to 2 ring three times If set to 3 cycle ring To show the namelist display mode lf set to 0 it s th DT Config display mode lf set to 1 it s the Simulat 0 display mode To show the working mode lf set to 0 it s the apartment t Meee system mode lf set to 1 it s the villa mode 0 Note this section is set on DT Config software for more detail informations please refer to the DT Config software user instructions NameList Display Mode Table 3 Setup Item Language Tone Select Tone Volume Unlock Code Display Mode Clock Setup Code About Default T F r Description ACO set To change language the code format is 4 digits Please refer to part 5 section 10 change doo
7. d Card page Please see the followings 1 AddCard 1 AddCard 1 AddCard ie 01 01 Card numbs 15977131 Please Input Room Code Show the card Show The Card Back Save Back Save D 4 EN vA Q Enter Add Card menu and Input Room Code Read the card to be Room Code is asked authorized Delete user cards Registered User Cards Key Fobs can be deleted from the Door station once doing the delete operation the card key fobs can not open the door anymore They can also be re registered again to become a valid User Card User Key Fob There are two ways to delete User Cards User Key Fobs 1 Delete by card show the unwanted card s when the Door station is in Delete Card Mode 2 Delete by room number delete all the registered User Cards related to that room number Delete By Card In Debug State Press 1 gt 3 Card Manage gt 2 Delete By Card to enter Delete by Card page as shown on the right then show the cards you want to delete one by one Delete by Room Number In Debug State Press 1 gt 3 Card Manage gt 3 Delete By M Code to enter Delete by M Code page as shown on the right then Input the Room Code press to confirm all associated cards will be deleted 2 Delete By Card Show The Card 3 Delete By M code Please Input Room Code 2 Delete By
8. dc 1 5A e The Jumper must be removed when using external power supply The default setting is Power to Unlock type Normally open mode if use Power off to Unlock type change the Unlock Relay mode to Normally closed mode Note that the unlock relay mode is set on the Parameter tab of DT CONFIG software e f different unlocking time is needed to be configured please use the DT CONFIG software to change the setting on the Parameter tab see the program section C Connection for Power to Unlock type set to Normally Open on the Unlock Relay mode on DT config software default Note Cut off this line when Remove the Jumper FES using external power supply JP_LK D Connection for Power off to Unlock type set to Normally Closed on the Unlock Relay mode on DT config software Note Cut off this line when using external power supply 5 Door Station Configurations 1 About room code address Room Code also called room address is a code assigned to each monitor to identify different monitors each monitor have a unique room code in one buidling The room Code is stored in each Monitor s inner EEPROM memory and does not lose even the monitor is power off 2 About Debug State The Debug State is your starting point for using all the applications on DPC D218 Redial a Tools 9008 Exits OOO OOO 000 ODO Q When Door Station is in input 900
9. l mounting 4 Door Lock Connections 1 Internal Power Supply Mode Use the power of the system to supply for the electronic lock so that the lock can be connected to the door station directly without an additional power supply for the electronic lock Note that the door station can only output 12Vdc power therefore the kind of lock is limited e The rated power of the lock must be less than 12Vdc 300mA when using internal power supply mode The GND must connect to the negative of the lock and the COM connect to the positive e Jumper set to 1 2 position for Power to Unlock safety type Normally open mode set to 2 3 position for Power off to Unlock type Normally closed mode Note that the unlock relay mode is set on the Parametertab of DT CONFIG software e If different unlocking time is needed to be configured the DT CONFIG software can be used to change the Unlock Timing on the Parameter tab see the program section A Connection for Power to Unlock type set to Normally open on the Unlock Relay mode on DT config EB software 12V 300mA ON Jumper set to 1 2 position JP_LK B Connection for Power off to Unlock type set to Normally Closed on the Unlock Relay mode on DT config software Jumper set to 2 3 position JP_LK 2 External Power Supply Mode When the electronic lock is over 12 Vdc additional power supply for the lock is needed e The power supply for the lock must be less than 48V
10. nitor code 4 4 Online Monitors Search Range input the monitor adress For example o Online input the range from 01 to 05 You will see the connection ee ei status of the selected moinitors 05 Online Back 13 Namelist function DJ LCD ID is designed to have digital keypad and big TFT screen Its namelist was shown on the screen and customer can do the calling operation through the digital keypad guided by Namelist on the screen 2 types of namelist can be shown on the screen DT Config namelist and Simulate namelist Enter namelist page Press 9 in standby mode to display the user namelist Press key to scroll next last page and use key 1 to 8 key on each page to call the flat you want Please refer to the DT Config softwre user instructions for configure the namelist Send namelist to monitors The namelist can be sent to monitors by door station directly Connect the door station and montiors correctly to the system Then press 8012 in standby mode and input password 66666666 by default to send namelist to all the monitors 6 Specification e Power supply e Camera Lens e Power consumption e Screen e Resolution e Video signal DC24V Powered by DPA D2A 1 4 ACS 4T image sensor with DSP processor Standby 3W Working status 9W 3 5 inch TFT 320 R G B X240 pixels CCIR EIA Optional
11. ode Default Factory set If only one door station is installed in this building set to 1 If multi door stations are installed primary door station 1 must be set to 1 and other slave door stations must eile be set from 2 to 4 Note that max 4 door stations is available in one building To set the time that how long the door keeps open 05 when door is released Range from 01 to 99 seconds 5 seconds To set the unlock mode to match the corresponding lock Rand from 0 to 1 To set the card location lf set to 0 the card is saved in door station lf set to 1 the card is saved in DPA D2 IPC To set the calling mode lf set to 0 it s the auto mode that means the calling will be activated directly 0 after inputting 2 digits code lf set to 1 it s the manual Auto mode mode that means you should press button to activate the calling after inputting the code 0 0 To set the talking mode lf set to 0 hands free mode is 0 activated lf set to 1 handset mode is activated To show the parameters please refer to table 2 1 To change door station administrator code 66666666 Note this operation is irreversible Once restore is activated all parameters will return to factory defaul setting except the information of access card Table 2 1 Parameters set Monitor Timing To show the monitor time Range from 6s to 600s 30s Switch Timin To show the surveillance time for each Door Station or 405 9 CCT
12. r station language for more 01 detail informations Select the chime of Door Station in calling wait state 12 03 chord tunes are available key in 01 to 12 to select Adjust the tone volume for dooor station in calling Rang from 08 01 15 To change unlock code in Common Code Unlock mode in 1111 4 digits format 1111 is the default unlock code To select the Door Station screen menu If set to 0 the screen displays the visitor s image when talking lf set to 1 the 0 screen displays icons when talking To set date and time Date format if set to 0 date format is DD MM YY if set to 1 date format is MM DD YY Time format if set to 0 time format is 24 hour standard If set to 1 time format is12 hour standard To change the Program Code 88888888 1 Hardware version To show the Door Station including ACS hardware information 2 Software version To show the Door Station including ACS software information 3 Manufacture Date To show the manufacturing date 4 Dialing Counts To show the call operation counts 5 Calls Counts To show the established calling counts 6 Unlock Counts To show the unlock operation counts T Standby Voltage To show the voltage that the door Station in standby 8 Working Voltage To show the voltage that the door Station in working 9 Video Standard PAL or NTSC standard 10 UI_CODE To show the UI byte counts and check box 11 MCM VER To show the version and lang
13. tion runs as Debug State you can press 1 to activate Tools Menu then select 2 to enter setup page then select 4 item lf it runs as Normal State follow these steps 1 3 Language 1 Tone Select 03 Tone Volume 03 Setup 5 Display Mode jo 6 Ji 8 9 Clock Setup Code About Default 4 Unlock Codel 1111 Press Input 8002 Press 4 to enter unlock then input Setup Code or code item Admin Code 88888888 or 66666666 by default 10 User Card Management Input 4 digits number then press to update This section explains how to configure the key fob function on DPC D218 The key fob is used to open the lock Total 1000 key fobs can be registered with one door station When swiping the fob to the door station the distance must be less than 3 centimeter Key Fobs must be registered on the Door station that can be used to open the door Register the Key Fobs All the registered key fobs are called User Cards User Key Fobs New fobs cards need to be registered one by one to the Door station to become a valid User Card User Key Fob and every User Card User Key Fob is related to a certain Monitor Address Flat code When the Doors tation is standby press gt 9008 gt Password 66666666 by default to get into the Debug Mode Menu then Press 1 gt 3 Card Manage gt 1 Add Card to get into the Ad
14. tors which its code is from 00 15 Input 02 to call the monitors which its code is from 16 31 please refer to table 2 1 working mode 5 About Default Set The Default Set is very important When the door station miss up the settings in anyway the most quickly and easy way to solve the problem is to activate the default setting on door Station The default settings already have all the right settings for one building system that means the system will work normally without any additional settings ID Code 1 Unlock Timing 05 Unlock Output 0 Card Memory 0 Doorplate Mode Redial Installer Setup Installer Setup Setup Tools Card Memory Press No Audio Options Pres NO Online Monitors to select 7 Parameters Exits to select Online Devices 8 Installer Code 8 Voltage Measure Back 9 Default Back In Debug State press 1 In Tools menu press 1 Press 9 key a key key password will be asked 9 Default Please Input Password Back Save Input Installer code 66666666 by default then press to save 6 Change Ring Tone There are 12 different ringtones If door station runs as Debug State you can press 1 gt 2 Setup gt 2 Tone Select to enter tone setting page If it runs as Normal State follow these steps 1 Language 1 E Seleen ie Setup 3 Tone Volume 03 8002 Unlock Code 1111
15. uage for MCM 12 Updated To show the updated time for UI Restore all Setup parameters to factory default setting Please note that this operation is an irreversible Table 4 Card Memory Factory Item Description set Add Card To add the user card Delete By Card To delete card by user card Delete By M code To delete card by room code Cards Information To show the informations about cards Format To format informations about cards 4 Calling and Unlock Operation The DPC D218 door station is a digital station with 320 240 pixels LCD screen color CCD camera night view LED and digital keypad Visitors can call the apartment by dialing the Flat Code apartment number on the keypad lf they don t know the Flat Code apartment number they can search the name list on the screen If the door station is in standby visitors need to press 9 to display the user name list Press key to scroll next last page and use key 1 to 8 key on each page to call the desired flat Residents can open the door by using their unique Unlock Code four digit PIN code If the door station is in standby mode press key then input the four digit unlock to open the door Please refer to part 5 section 7 How to use code unlock function for more detail information Note If the door station works as apartment system mode input 01 32 to call the relevant monitor lf the door station works as villa mode input 01 to call the moni
Download Pdf Manuals
Related Search
Related Contents
Weider WESY9730 User's Manual バージョン(1.10a)用 User manual Method for displaying hairstyles Sandberg Printer Cable IEEE 1.8m User Manual - Axis Communications IN1176 Operating Instructions IT33 Edition B Panas。n曜 Copyright © All rights reserved.
Failed to retrieve file