Home
FP2080CHB User Manual - Richardson Electronics
Contents
1. contact with Mali se ON any part inside this unit This symbol alerts the user that important literature concerning the operation and maintenance of this unit has been included Therefore it should be read carefully in order to avoid any problems Protective earth terminal marked i DC Input When operating the Medical Display with a 220 240V AC power source in Europe use the power cord provided with the monitor In the UK a BS approved power cord with a moulded plug has a Black five Amps fuse installed for use with this equipment If a power cord is not supplied with this equipment please contact your supplier When operating the Medical Display with a 220 240V AC power source in Australia use the power cord provided with the monitor If a power cord is not supplied with this equipment please contact your supplier For all other cases use a power cord that matches the AC voltage of the power outlet and has been approved by and complies with the safety standard of your particular country Main switch OFF User s Manual Safety Logo Ao mo D RESPECT 1 Authentication sign of Standard Inspection Bureau for U S A Complies with UL 60601 1 AND CAN CSA C22 2 NO 601 1 capes 2 mA Authentication sign of Standard Inspection Bureau for Canadian and U S A safety standard at the same time Complies with UL60950 CAN CSA C22 2 N60950 1 F03 The LCD monitor compl
2. items and increase adjustment when OSD is shown Press the to selection sub menu items and decrease adjustment when OSD is shown Start the OSD feature Menu Exits the OSD controls Exits to the OSD main menu Refer to the Hot Key Controls section User s Manual Main Menu Main Menu OSD Function Brightness Adjust the brightness of the screen Exit Exit sub menu Brightness Contrast Adjust the contrast of the image Contrast Exit Exit sub menu Gamma Off Off gamma function Gamma 1 8 Set the Gamma value to 1 8 Gamma 2 0 Set the Gamma value to 2 0 Gamma 2 2 Set the Gamma value to 2 2 Gamma DICOM Gamma Set the Gamma to standard value Gamma User Set the Gamma value for user Exit Exit sub menu Light 300 Set the light sensor to 300 Light Sensor Light 400 Set the light sensor to 400 Color Temp Green Gain from Color Temp _ User Color User Green Green Gain from Color Temp User Blue Blue Gain from Color Temp Shows the information of the current settings include HFREQ Horizontal Scanning Frequency VFREQ Vertical Scanning Frequency Information Res Display Resolution Model The Model of MCU amp FPGA Mver MCU Version Fver FPGA Version Reset Restore to factory settings Exit Exit OSD menu 8 User s Manual Recorrrrended Use For optimum performance please note the following when setting up and using the multisync LCD monitor not open the moni
3. monitor screen and turn clockwise from Landscape to Portrait or counterclockwise from Portrait to Landscape Note To rotate OSD menu between landscape and portrait refer to OSD Controls section OSD ROTATION function User s Manual Tilt and Swvel Monitor Screen Figure 03 Figure 04 Tilt Swivel Grasp top and bottom sides of the monitor screen with Grasp both sides of the monitor screen with your your hands and adjust the tilt as desired hands and adjust the swivel as desired Note If the screen is rotated counterclockwise the tilt function is not available Note Handle with care when tilting the monitor screen Package Contents Included with your LCD monitor are following items OM A N ACY N 18 sy 1pcs 1pcs 1pcs User s Manual DVI Cable Power Cord CD ROM Quick Setup User s Manual OSD Controls Your LCD monitor allows you to easily adjust the characteristics of the image being displayed All of these adjustments are made using the control buttons on the monitor While you use these buttons to controls an OSD shows you their change d Mode d Meny Main Function Menu Power Indicator Green Normal TONGI Orange Power Saving No Signal Off Power Off Source Gamma items selection Mode Show Information Enter Access and control the function of sub menu when OSD is shown Press the to selection sub menu
4. mouse If no video is present on the screen turn the Power button off and on again LED on monitor is not lit no Power Switch should be in the ON position and power cord should be connected green or amber color can be seen Check the power cable should be connected surely No tilt Refer to the Quick Start section Remove monitor stand for mounting to insure correct installation of stand Refer to the Quick Start section Remove monitor stand for mounting to insure correct installation of stand 13
5. SM IMAGESYSTEMS FP 2080CHB MEDICAL DISPLAY USER S MANUAL High Bright Color User s Manual IMPORTANT SAFETY INSTRUCTIONS WARNING AND CAUTION EXPLANATION OF GRAPHICAL SYMBOLS SAFETY LOGO FCC INFORMATION MANUFACTURER S RECYCLING AND ENERGY INFORMATION CLASSIFICATION QUICK START RAISE AND LOWER MONITOR SCREEN SCREEN ROTATION TILT AND SWVEL MONITOR SCREEN PACKAGE CONTENTS OSD CONTROLS TO MAKE OSD AD USTMENTS OSD FUNCTION RECOMMENDED USE CLEANING PRODUCT SPECIFICATIONS SPECIFICATIONS DISPLAY MODE FEATURES TROUBLESHOOTING gt U WN N N Ul NO HD 10 11 11 12 12 13 User s Manual IMPORTANT SAFETY INSTRUCTIONS Warning and Caution Warning To prevent fire or shock hazards do not expose this unit to rain or moisture Also do not use this unit s polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully inserted Refrain from opening the cabinet as there are high voltage components inside Refer servicing to qualified service personnel Caution To reduce the risk of electric shock make sure power cord is unplugged from wall socket To fully disengage the power to the unit please disconnect the power cord from the ac outlet Do not remove cover or back No user serviceable parts inside Refer servicing to qualified service personnel Caution Medical Display is intended to use in displaying imag
6. as DVI and P amp D P amp D Plug and Display The VESA standard for digital flat panel monitor interfaces It is more robust than DFP since it allows for other options off a signal connector options like USB analog video and IEEE 1394 995 The VESA committee has recognized that DFP is a subset of P amp D As a DVI based connector for the digital input pins only a simple adapter is necessary for compatibility between P amp D and other DVI based digital connector such as DVI and DFP Pivoting Stand Allows users to adjust the monitor to the orientation that best fits their application either Landscape orientation for wide documents or portrait orientation for the ability to preview a full page on one screen at one time The Portrait orientation is also perfect for full screen video conferencing Color Control Systems Allows you to adjust the colors on your screen and customize the color accuracy of your monitor to a variety of standards OSD On Screen Display Controls Allow you to quickly and easily adjust all elements of your screen image via simple to use OSD Ergo Design Features Enhance human ergonomics to improve the working environment protect the health of the user and save money Examples include OSD controls for quick and easy image adjustments tilt base for preferred angle of vision Intelligent Power Manager System Provides innovative power saving methods that allow the monitor to shift to a lower power cons
7. ck the Vacation Switch should be in the ON position Front Power Switch and computer power switch should be in the ON position iii Check to make sure that a supported mode has been selected on the display card or system being used Please consult display card or system manual to change graphics mode Check the monitor and your display card with respect to compatibility and recommended settings Check the signal cable connector for bent or pushed in pins Ensure the DVI input mode is set to DIGITAL when the MAC digital output is connected to the DVI I connector Perisi Image persistence is when residual or ghost image of a previous image remains visible the screen To 9 alleviate image persistence turn off the monitor for as long as the previous image was displayed Signal cable should be completely attached to the computer Image is unstable unfocused or swimming is Check the monitor and your display card with respect to compatibility and recommended signal timings apparent If your text is garbled change the video mode to non interlace and use 60Hz refresh rate Use the OSD Image Adjust controls to increase or decrease the Coarse total OSD is not sized properly Check to make sure that a supported mode has been selected on the display card or system being used Signal cable should be completely attached to the computer No signal Make certain the computer is not in a power saving mode touch the keyboard or
8. d on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult your dealer or an experienced radio TV technician for help If necessary the user should contact the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock No 004 000 00345 4 User s Manual Manufacturer s Recycling and Energy Information Disposing of your old product Within the European Union EU wide legislation as implemented in each Member State requires that waste electrical and electronic products carrying the mark left must be disposed of separately from normal household waste This includes monitors and electrical accessories such as signal cables or power cords When you need to dispose of your display products please follow the guidance of your local authority or ask the shop where you purchased the product or if applicable follow any agreements made between yourself s The mark on electrical and electron
9. dusty or oily areas Do not cover vent on monitor If monitor or glass is broken do not come in contact with the liquid crystal and handle with care Caution Allow adequate ventilation around the monitor so that heat can properly dissipate Do not block ventilated openings or place the monitor near a radiator or other heat sources Do not put anything on top of monitor The power cable connector is the primary means of detaching the system from the power supply The monitor should be installed close to a power outlet which is easily accessible Handle with care when transporting Save packaging for transporting Image persistence is when a residual or ghost image of a previous image remains visible on the screen LCD monitors image persistence is not permanent but constant images being displayed for a long period of time should be avoided To alleviate image persistence turn off the monitor for as long as the previous image was displayed For example if an image was on the monitor for one hour and a residual image remains the monitor should be turned off for one hour to erase the image 0 oe Oe Q Q 5 Correct placement and adjustment of the monitor can reduce eye shoulder and neck fatigue Check the following when you position the monitor For optimum performance allow 20 minutes for warm up Adjust the monitor height so that the top of the screen is at or slightly below eye level Your eyes should look slightl
10. es for review and analysis by trained medical practitioner for diagnose in CT MRI HIS and PACS This device is not suitable for a digital mammography system Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade That SIP SOPs need to be connected properly and that any unused SIP SOPs shall not be accessible for the patient to contact the patient area after the LCD is integrated into a medical system Caution To prevent electric shock please do not remove cover or any internal components Refer to a qualified technician for service Unplug the monitor from the power outlet before cleaning Use a damp cloth Please follow the national guidelines for unit disposal This product can not be used for a life support system The unit is for exclusive interconnection with IEC 60XXX certified equipment outside of patient environment and 60601 1 certified equipment inside the patient environment Contact Information RICHARDSON ELECTRONICS Display Systems Group 12975 16 Ave N Suite 300 Plymouth MN 55441 Sales 888 735 7373 TEKLINK Technical Support www teklink rell com www imagesystemscorp com Explanation of Graphical Symbols This symbol warns user that un insulated voltage within the unit may have sufficient magnitude to cause electric shock Therefore it is dangerous to of
11. ic products only applies to the current European Union Member States Outside the European Union If you wish to dispose of used electrical and electronic products outside the European Union please contact your local authority so as to comply with the correct disposal method Classification Adapter SKYNET SNP A127 M No Applied Part No protection against the ingress of water IPX0 Mode of operation Continuous Operation The equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Not AP or APG Category User s Manual Quick Start To attach the LCD monitor to your system follow these instructions 1 Turn off the power to your computer 2 For the PC Connect the DVI signal cable to the connector of the display card in your system Tighten all screws For the PC with Analog output Connect the 15 pin mini D SUB to DVI A signal cable to the connector of the display card in your system Figure A 01 3 Connect the DVI signal cable to the connector on the back of the monitor Place the video signal cable Figure A 01 Note Incorrect cable connections may result in irregular operation damage display quality components of LCD module and or shorten the module s life Note Collect cables and keep them in the stand with cable cover The cable cover can be attached on the front or back side of Tilt Stand Please check Tilt Rise and Lower monitor screen and sc
12. ies with the 93 42 EEC EN60601 1 EN60601 2 of related European standards We hereby declare that the equipment specified above conforms to the technical standards as specified in the FCC Rules FCC Information Use the attached specified cables with the Medical Display so as not to interfere with radio and television reception 1 The power supply cord you use must have been approved by and comply with the safety standards of U S A and meet the following condition Power supply cord Non shield type 3 conductor Hospital Grade Plug Length 2 0m Plug shape U S A 2 Please use the supplied shielded video signal cable 15 pin mini D SUB to DVI A cable or DVI D to DVI D cable Use of other cables and adapters may cause interference with radio and television reception This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off an
13. reen rotation when you manage cables 4 Connect one end of the power cord to the AC inlet the back of the monitor and the other end to the power outlet Note Please refer to Caution section of this manual for proper selection of AC power cord 5 The Vacation Switch on the left side of the monitor must be turned on Turn on the monitor with the front power button Note The Vacation Switch is a true on off switch If this switch is on the OFF position the monitor cannot be turned on using the front button 6 Turn on the computer No touch Auto Adjust automatically adjusts the monitor to optimal settings upon initial setup for most timing For further adjustments refer to the OSD section of this User s Manual Note If you have any questions please refer to the Troubleshooting section of this User s Manual 2 DVI CABLE POWER CORD Figure A 01 Raise and Lower Monitor Screen The monitor may be raised or lowered in either Portrait or Landscape mode To raise or lower screen place hands on each side of the monitor and lift or lower to the desired height Note Handle with care when raising or lowering the monitor screen Screen Rotation Before rotating the screen must be raised to the highest level to avoid knocking the screen on the desk or pinching with your fingers To raise the screen place hands on each side of the monitor and lift up to the highest position Figure A 02 To rotate screen place hands on each side of the
14. tch or rub the screen with a hard object Never use of the following solvents on the Medical Display Harsh chemicals may cause damage to the cabinet and the touch sensor Thinner Spray type cleaner Benzene Wax Abrasive cleaner Acid or Alkaline solvent CABINET Remove dirt with a lightly moistened cloth and a mild solvent detergent Then wipe the cabinet with a soft dry cloth 10 User s Manual Product Specifications Specifications Specifications FP2080CHB Panel LCD Display TFT LCD Color Characteristics a 21 3 inches Pixel Pitch 0 2115 H x 0 2115 V Viewing Angle Horizontal 170degrees CR gt 10 Conditions Storage Temperature 20C 60 C 10 95 Non Condensing The Top Level Assembly shall meet the Packaging Specification EER gt 11 User s Manual Display Mode Model FF2080CHB Vertical Scannin Horizontal Scannin Features DVI The integrated interface ratified by the Digital Display Working Group DDWG that allows both digital and analog connectors off of one port The l stands for integration for both digital and analog The digital portion is DVI based DFP Digital Flat Panel An all digital interface for flat panel monitors which is signal compatible with As a DVI based digital only connection only a simple adapter is necessary for compatibility between DFP and other DVI based digital connectors such
15. tor There are no user serviceable parts inside and opening or removing covers may expose you to dangerous shock hazards or other risks Refer all servicing to qualified service personnel Do not spill any liquids into the cabinet or use your monitor near water Do not insert objects of any kind into the cabinet slots as they may touch dangerous voltage points which can be harmful or fatal or may cause electric shock fire or equipment failure place any heavy objects on the power cord Damage to the cord may cause shock or fire Do not place this product on a sloping or unstable cart stand or table as the monitor may fall causing serious damage to the monitor Do not place any objects onto the monitor do not use the monitor outdoors inside of the fluorescent tube located within the LCD monitor contains mercury Please follow the bylaws or rules of your municipality to dispose of the tube properly Immediately unplug your monitor from the wall outlet and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is damaged If liquid has been spilled or objects have fallen into the monitor If the monitor has been exposed to rain or water If the monitor has been dropped or the cabinet damaged If the monitor does not operate normally by following operating instructions Do not bend power cord Do not use monitor in high temperature humid
16. umption level when on but not in use saving of your monitor energy costs reducing emissions and lowering the air conditioning costs of the workplace Multiple Frequency Technology Automatically adjusts monitor to the display card s scanning frequency thus displaying the resolution required FullScan Capability Allow you to use the entire screen area in most resolutions significantly expanding image size Wide Viewing Angle Technology Allows the user to be able to see the monitor from any angle from any orientation Portrait or Landscape Provides the same viewing angles either up down left or right Gamma Internal circuitry automatically converts 8 bit data from the PC to 10 bit and back to 8 bit producing smooth Gamma can be set by using preset values or creating a custom setting 12 User s Manual Troubleshooting If the Medical Display fails to function correctly please follow these steps for a possible solution 1 Perform the adjustments according to Quick Start section 2 Refer to the following troubleshooting chart if you cannot resolve the problem from other sections of this Users Guide 3 If the problem is not described below or you cannot correct the problem stop using the monitor and contact your dealer or the nearest service center for further assistance The signal cable should be completely connected to the display card computer The display card should be completely seated in its slot Che
17. y downward when viewing the middle of the screen Position your monitor no closer than 40 cm and no further away than 70 cm from your eyes The optimal distance is 50 cm Rest your eyes periodically by focusing on an object at least 50 cm away If reflected light makes it hard for you to see your screen use an anti glare filter Adjust the monitor s brightness and contrast controls to enhance readability Use a document holder placed close to the screen Avoid displaying fixed patterns on the monitor for long periods of time to avoid image persistence after image effects Get regular eye checkups 0 0 Q0 000 OF m rgonomics o realize the maximum ergonomics benefits we recommend the following Adjust the backlight to best state Do not position the Contrast control to its maximum setting Use the preset Size and Position controls with standard signals Use the preset Color Setting Do not use primary color blue on a dark background as it is difficult to see and may produce eye fatigue to insufficient contrast o ooo User s Manual CLEANING WARNING If you dropped any material or liquid such as water onto the monitor when cleaning unplug the power cable immediately and contact your dealer or the nearest service center Always make sure your hands are dry when unplugging the power cable AN cation For safety reasons turn off the power switch and unplug the monitor before cleaning Do scra
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung - Lohrmann Samsung GT-S3030 用戶手冊 16-9-bordmonitor_mit_navi_0700 Samsung NP-N208 User Manual (FreeDos) HP 1y SecureDoc WinEntr Supp 5K+ E-LTU end-user license agreement for microsoft software Cisco Systems 1080P12X Webcam User Manual PGS S27 User's Manual Copyright © All rights reserved.
Failed to retrieve file