DATA SHEET

image

Contents

1. 10 of range per lead for 200 2k ranges 1 k per lead on all other ranges Input Protection oo ee eeeeeeeeeeeeeeeeees 1000 V on all ranges Input Characteristics Resolution Range 8 1 2 Digits Current Source Slow Medium Fast 200 199 999 0 001 0 01 0 01 0 8 mA 2k 1 99999 k 0 01 0 1 0 1 0 8 mA 20 k 19 9999 k 0 1 1 1 0 08 mA 200 k 199 999 k 1 10 10 0 008 mA 2M 1 99999 M 10 100 100 0 9 pA 20M 19 9999 M 100 1k 1k 0 16 pA 100 M 100 000 M 1k 10k 10k 0 16 uA 10 M Accuracy Accuracy Range AE ae 23 C 5 C 23 C 5 C 200 0 02 0 004 0 03 0 004 0 003 0 0006 2k 0 015 0 002 0 02 0 003 0 003 0 0005 20 k 0 015 0 002 0 02 0 003 0 003 0 0005 200 k 0 015 0 002 0 02 0 003 0 003 0 0005 2M 0 03 0 003 0 04 0 004 0 004 0 0005 20 M 0 2 0 003 0 25 0 003 0 01 0 0005 100 M 1 5 0 004 1 75 0 004 0 2 0 0005 Notes 1 Accuracy given as of reading of range DC Current Input Protection ccecceceeeeseeeeeeeeteteeeeeeeees Tool accessible 11 A 1000 V and 440 mA 1000 V fuses Shunt Resistance 0 0 0 cece eeeeeeeeeneeeeeeeees 0 01 for 2 A and 10 A ranges 1 for 20 mA and 200 mA Burden voltage lt 1 mV for 200 uA and 2 mA range Input Characteristics Resolution Full Scale Burden Voltage Range 5 1 2 Digits Slow Medium Fast 200 uA 199 999 pA 0 001 pA 0 01 pA 0 01 pA lt 1 mV 2 mA 1999 99 pA 0 01 pA 0 1 pA 0 1 pA lt 1 mV 20 mA 19 9999 mA 0 1 pA 1 uA
2. Rapid DATA SHEET Order code Manufacturer code 85 3503 FLUKE 8808A 5 5 DIGIT BENCH MULTIMETER Page1lof 9 The enclosed information is believed to be correct Information may change avithout noticeGdue to Revision A product improvement Users should ensure that the product is suitable for their use E amp O E 20 02 2007 Sales 01206 751166 Technical 01206 835555 Fax 01206 751188 Sales rapidelec co uk Tech rapidelec co uk www rapidonline com FLUKE Fluke SSO8A Digital Multimeter Extended Specifications Making measurements is as simple as pushing a button The Fluke 8808A 5 5 digit multimeter has a broad range of functions measuring volts ohms and amps with a basic V dc accuracy of 0 01 It is remarkably easy to use even by unskilled operators because it makes the measurements you perform most often extremely easy and fast to do Six setup buttons on the 8808A front panel operate like a car radio s station presets Simply set up the meter for a common measurement then press shift followed by a setup button S1 to S6 to save the e 5 5 digit resolution setup Now each time you e Basic V dc accuracy of 0 01 perform that measurement you e Dual display simply press the appropriate Features at a glance setup key It s that easy e Dedicated dc leakage current measurement The setup buttons eliminate e 2x4 ohms 4 wire measurement technique Lael ea pas ong e Six dedicat
3. 0 00 ee To minimize measurement errors shield inputs from external noise when measuring low voltage low frequency signals Accuracy Accuracy Temperature Range Frequency 90 days 1 year Coefficient C 23 C 5 23C 5 C Outside 18 28 C 20 Hz 2 kHz 0 01 0 002 0 01 0 003 0 002 0 001 100 mV to 2 kHz 20 kHz 0 01 0 002 0 01 0 003 0 002 0 001 750 V 20 kHz 200 kHz 0 01 0 002 0 01 0 003 0 002 0 001 200 kHz 1 MHz 0 01 0 004 0 01 0 006 0 002 0 002 Notes 1 Input gt 100 mv 2 Limited to 8 10 V Hz Continuity Continuity Threshold eee 20 Test Currents Response Time 000 000 cece ee eee eeeeeeeeeseeeeeneees 100 samples sec with audible tone Ratri norii sinadi ifan tens T andans Fast Resolution ciiin sinisiin 0 01 Diode Test Response Time ssania as 100 samples sec with audible tone Fast Maxiumum Reading 0 00cssesseeees 1 9999 V RESOlUWUON iis isis sissiicss ncates rinrin tees 0 1 mV Fluke 8808A Digital Multimeter Extended Specifications Fluke Corporation 7 FLUKE Ordering information Models Description 8808A 120V 5 5 Digit Multimeter 8808A 220V 5 5 Digit Multimeter 8808A 100V 5 5 Digit Multimeter 8808A 240V 5 5 Digit Multimeter 8808A SU includes 8808A package plus FlukeView Forms basic software USB to RS 232 interface adapter cable 8808A SU 120V 5 5 Digit Multimeter SW USB Cable Kit 8808A SU 220V 5 5 Digit Multimeter SW USB Cable
4. 0 35 0 05 0 01 0 005 50 kHz 100 kHz 0 8 0 05 0 9 0 05 0 05 0 01 2V 20 Hz 45Hz 0 8 0 05 0 9 0 05 0 01 0 005 45 Hz 20 kHz 0 15 0 05 0 2 0 05 0 01 0 005 20 kHz 50 kHz 0 3 0 05 0 35 0 05 0 01 0 005 50 kHz 100 kHz 0 8 0 05 0 9 0 05 0 05 0 01 20 V 20 Hz 45 Hz 0 8 0 05 0 9 0 05 0 01 0 005 45 Hz 20 kHz 0 15 0 05 0 2 0 05 0 01 0 005 20 kHz 50 kHz 0 3 0 05 0 35 0 05 0 01 0 005 50 kHz 100 kHz 0 8 0 05 0 9 0 05 0 05 0 01 200 V 20 Hz 45Hz 0 8 0 05 0 9 0 05 0 01 0 005 45 Hz 20 kHz 0 15 0 05 0 2 0 05 0 01 0 005 20 kHz 50 kHz 0 3 0 05 0 35 0 05 0 01 0 005 50 kHz 100 kHz 0 8 0 05 0 9 0 05 0 05 0 01 750 V 20 Hz 45Hz 0 8 0 05 0 9 0 05 0 01 0 005 45 Hz 20 kHz 0 15 0 05 0 2 0 05 0 01 0 005 20 kHz 50 kHz 0 3 0 05 0 35 0 05 0 01 0 005 50 kHz 100 kHz 0 8 0 05 0 9 0 05 0 05 0 01 Notes 1 Accuracy given as of reading of range 4 Fluke Corporation Fluke 8808A Digital Multimeter Extended Specifications FLUKE o FLUKE Resistance Specifications are for 4 wire resistance function or 2 wire resistance with REL If REL is not used add 0 2 for 2 wire resistance plus lead resistance Measurement Method 0 0 0 eens Current source referenced to LO input Max Lead Resistance 4 wire ohms
5. 1 uA lt 0 05 V 200 mA 199 999 mA 1 pA 10 pA 10 uA lt 0 5 V 2A 1 99999 A 10 pA 100 pA 100 pA lt 0 1 V 10A 10 0000 A 100 uA 1 mA 1 mA lt 0 5 V Fluke 88084A Digital Multimeter Extended Specifications Fluke Corporation 5 Accuracy Accuracy Range Temperature Coefficient C g 90 days 1 year Outside 18 28 C 23 C 5 C 23 C 5 C 200 uA 0 02 0 005 0 03 0 005 0 003 0 001 2mA 0 015 0 005 0 02 0 005 0 002 0 001 20 mA 0 03 0 02 0 04 0 02 0 005 0 001 200 mA 0 02 0 005 0 03 0 008 0 005 0 001 2A 0 05 0 02 0 08 0 02 0 008 0 001 10A 0 18 0 01 0 2 0 01 0 008 0 001 Notes 1 Accuracy given as of reading of range AC Current The following ac current specifications are for sinusoidal signals with amplitudes greater than 5 of range For inputs from 1 to 5 of range add an additional error of 0 1 of range Input Protection Measurement Method AC coupled True RMS Shunt Resistance 0 0 0 eee 0 01 for 2 Aand 10 A ranges 1 for 20 mA and 200 mA AC Filter Bandwidth SIOW vaiasnineisaitiasiania nnidianniimanian 20 Hz 100 kHz Maximum Crest Factol cccccecseeseeeeeseees 3 1 at Full Scale Additional Crest Factor Errors lt 100 Hz Crest Factor 1 2 0 05 of full scale Crest Factor 2 3 0 2 of full scale Input Characteristics Tool accessible 11 A 1000 V and 440 mA 1000 V
6. Kit 8808A SU 100V 5 5 Digit Multimeter SW USB Cable Kit 8808A SU 240V 5 5 Digit Multimeter SW USB Cable Kit 8808A includes Meter TL71 test leads line cord spare line fuse statement of cal prac tices WEEE information sheet Warranty statement Getting Started guide English French German Spanish Italian Simplified Chinese Japanese CD Rom with user manual English Fluke Keeping your world up and running Fluke Corporation PO Box 9090 Everett WA USA 98206 Fluke Europe B V PO Box 1186 5602 BD Eindhoven The Netherlands For more information call n the U S A 800 443 5853 or Fax 425 446 5116 In Europe M East Africa 31 0 40 2675 200 or Fax 31 0 40 2675 222 In Canada 800 36 FLUKE or Fax 905 890 6866 From other countries 1 425 446 5500 or Fax 1 425 446 5116 Web access http www fluke com 2007 Fluke Corporation Specifications subject to change without notice Printed in U S A 9 2007 3093965 D EN N Rev B Pub_ID 11288 eng Rev 01 8 Fluke Corporation Fluke 8808A Digital Multimeter Extended Specifications
7. ed buttons for fast access to instrument setups longer need to press multiple e Hi Lo limit compare for Pass Fail testing buttons to set up a measurement e Fluke 45 remote command emulation function and range test limits or enter other parameters to make a measurement Whether you are performing The 8808A display has a E functional tests or making built in enunciators that clearly Eliminate production critical measurements on test Show the operator whether a _ mistakes points using the limit compare test passes or fails The pass fail The Fluke 8808A 5 5 digit mode with pass fail indicators Mdicators take the guesswork out of testing the result is either multimeter dependably performs eliminates production mistakes wtr limits oF ive out the most common measurements especially those where results required by today s applications are on the edge 8808A Specifications Voltage TOOV Setting nisn 90 V to 110 V 120V Setting icaro anaa 108 V to 132 V 220V Setting censis 198 V to 242 V 240V Setting 216 V to 264 V Frequency 47 Hz to 440 Hz Power Consumption 0 0 0 0 0 cece 15 VA peak 10 W average Dimensions 88 mm 3 46 in 217 mm 8 56 in 297 mm 11 7 in 2 1 kg 4 6 Ibs Display Vacuum Fluorescent Display segment Environment Temperature Operating 0 C to 50 C Storage 740 C to 70 C Warm Ups cscisccctieuest stipiccrenti ct ncient etnies hour to full uncertainty s
8. fuses Resolution Full Scale Burden Voltage Range 5 1 2 Digits Slow Medium Fast 20 mA 19 9999 mA 0 1 pA 1 pA 1 pA lt 0 05 V 200 mA 199 999 mA 1 pA 10 pA 10 pA lt 0 5 V 2A 1 99999 A 10 uA 100 uA 100 uA lt 0 1 V 10A 10 0000 A 100 pA 1 mA 1 mA lt 0 5 V Accuracy Accuracy Temperature Range Frequency 90 days 1 year Coefficient C 23 C 5 C 23 C 5 C Outside 18 28 C 20 mA 20 Hz 45Hz 1 0 05 1 25 0 06 0 015 0 005 45 Hz 2 kHz 0 25 0 05 0 3 0 06 0 015 0 005 200 mA 20 Hz 45Hz 0 8 0 05 1 0 06 0 015 0 005 45 Hz 2 kHz 0 25 0 05 0 3 0 06 0 015 0 005 2A 20 Hz 45Hz 1 0 05 1 25 0 06 0 015 0 005 45 Hz 2 kHz 0 25 0 05 0 3 0 06 0 015 0 005 10A 20 Hz 45Hz 1 0 1 1 25 0 12 0 015 0 005 45 Hz 2 kHz 0 35 0 1 0 5 0 12 0 015 0 005 Notes 1 Accuracy given as of reading of range 6 Fluke Corporation Fluke 88084 Digital Multimeter Extended Specifications FLUKE FLUKE Frequency Gate Time ningi aeiniacndcisnins 131 ms Measurement Method AC coupled input using the ac voltage measurement function Settling Considerations ee When measuring frequency after a dc offset voltage change errors may occur For the most accurate measurement wait up to 1 second to allow input blocking RC time constant to settle Measurement Considerations
9. ge specifications are for ac sinewave signals gt 5 of range For inputs from 1 to 5 of range and lt 50 kHz add an additional error of 0 1 of range and for 5O0kHz to 100 kHz add 0 13 of range Maximum Input 0000 cece eeeeeeeeeeeeeeees 750 V rms or 1000 V peak or 8 x 10 Volts Hertz product Measurement Method 0 0 0 cece AC coupled true rms Measures the ac component of input with up to 1000 V dc bias on any range AC Filter Bandwidth Eolo h AE EAEEREN TETT 20 Hz 100 kHz Common Mode Rejection 60 dB at 50 Hz or 60 Hz 1 k unbalance Maximum Crest Factor 0 ccccccseseeeeeeeees 3 1 at Full Scale Additional Crest Factor Errors lt 100 Hz Crest Factor 1 2 0 05 of full scale Crest Factor 2 3 0 2 of full scale Input Characteristics Resolution Range We Sits Input Impedance Slow Medium Fast 200 mV 199 999 mV 1 uV 10 uV 10 uV 1M o shunted by 2V 1 99999 V 10 uV 100 uV 100 uV P 20V 19 9999 V 100 uV 1000 uV 1000 uV 200 V 199 999 V 1 mV 10 mV 10 mV 750 V 750 00 V 10 mV 100 mV 100 mV Accuracy Accuracy Temperature Range Frequency 90 days 1 year Coefficient C 23 C 5C 23 C 5C Outside 18 28 C 200 mV 20 Hz 45Hz 0 8 0 05 0 9 0 05 0 01 0 005 45 Hz 20 kHz 0 15 0 05 0 2 0 05 0 01 0 005 20 kHz 50 kHz 0 3 0 05
10. ns Maximum Input Common Mode Rejection Normal Mode Rejection A D Nonlinearity Input Bias Current Settling Considerations 2 2 1 1000 V on any range 120 dB at 50 or 60 Hz 0 1 1 KQ unbalance nig 80 dB at Slow Rate 15 ppm of range sisi lt 30 pA at 25 C DN Measurement settling times are affected by source impedance cable dielectric characteristics and input signal changes Input Characteristics Full Scale Resolution Range 5 1 2 Digits ay meni Faa Input Impedance 200mV 199 999 mV 1 uV 10 uV 10 uV gt 10 G 2V 1 99999 V 10 uV 100 uV 100 uV gt 10 G 20V 19 9999 V 100 uV 1000 uV 1000 uV 10M 1 200 V 199 999 V 1 mV 10 mV 10 mV 10M 1 1000 V 1000 00 V 10 mV 100 mV 100 mV 10M 1 Notes 1 At some dual display measurements the input impedance of 200 mV and 2 V ranges may be changed to 10M Accuracy Accuracy Range 90 days 1 year TomBntside 18 28 C 23 C 5 C 23 C 5 C 200 mV 0 01 0 003 0 015 0 004 0 0015 0 0005 2V 0 01 0 002 0 015 0 003 0 001 0 0005 20V 0 01 0 003 0 015 0 004 0 0020 0 0005 200 V 0 01 0 002 0 015 0 003 0 0015 0 0005 1000 V 0 01 0 002 0 015 0 003 0 0015 0 0005 Notes 1 Accuracy given as of reading of range Fluke 8808A Digital Multimeter Extended Specifications Fluke Corporation 3 AC Voltage Specifications AC Volta
11. pecifications Relative Humidity non condensing OPGTAtiNG PE Uncontrolled lt 10 C lt 90 10 C to 30 C lt 75 30 C to 40 C lt 45 40 C to 50 C SLOLAGS A E E T 40 C to 70 C lt 95 Altitude Operan raisi a 2 000 Meters LOLA C si sisioiscstias sessedseicscdncasttaniacicaadansteae teat cdateaaes 12 000 Meters Vibration aai asr ai Complies with MIL PRF 28800F Class 3 Safety Complies with IEC 61010 1 2001 ANSI ISA 61010 1 S82 02 01 2004 UL 61010 1 2004 CAN CSA C22 2 No 61010 1 2004 CAT I 1000V CAT II 600 V EMC Designed to comply with IEC 61326 1 1997 A1 1998 A2 2000 Triggering Trigger Delay vic caivcssiscsicstdcsssstsscacscouscsacnssnsstcesstared 400 ms External Trigger Delay es External Trigger Jitter a Trigger Input TTL Levels Trigger Output ciciscsccicsssccscsissssacisecsscansieesetsssesiconcceead 5 V max Math Functions Min max relative hold compare and dB functions Electrical Input Protection 1000 V all ranges COV ONT ATI GE cia cssccssssisazspsecacessancocstsssesesessasssarizccestarseans 10 on the largest ranges of all functions except continuity and diode test Remote Interfaces RS 232C Warranty One year 2 Fluke Corporation Fluke 8808A Digital Multimeter Extended Specifications FLUKE FLUKE o Electrical Specifications Accuracy specifications are valid for 5 1 digit mode and after at least a half hour warm up DC Voltage Specificatio