1. 600B to ve terminal of BUT and ve terminal of 600B to ve terminal of BUT By doing so the Reverse Polarity LED glows as shown 11 2 2 2 Selecting Ah Capacity Press the Ah Range key The select LED glows as shown The display will show the last selected stored Ah value Power ON default value is 7 Ah To change the value press the key again Display shows new value Keep on pressing till the desired Ah is obtained SE Locked N J o z To Lock the Ah capacity either press any key OTHER than the Ah Range key OR wait for about 10 seconds Your selected Ah value will automatically get locked and is indicated by the glowing of Locked LED 2 2 3 Conducting a Test Test can be conducted any time Ready Complete LED is ON by pressing the Load Test key By doing so the Test On LED starts glowing Typically it glows for about 2 seconds Thereafter the Ready test starts blinking The blinking time depends on the Ah range selected Thereafter it becomes steady AIN Load Test O J Ready Test on Note User cannot conduct a test while the Ready LED is blinking 12 2 2 4 Observing Result After a Test By default the Battery Voltage is displayed on the display To observe the Balance Capacity left press the Display Mode switch AX Mode Batt Balance Voltage Capacit va Display O SN Note Balance Capacity can have a meaningful val
2. Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 BK PRECISION Model 600B SLA Battery Capacity Analyzer USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation service and repair of this instrument Before applying power to this instrument e Read and understand the safety and operational information in this manual e Apply all the listed safety precautions e Verify that the voltage selector at the line power cord input is set to the correct line voltage Operating the instrument at an incorrect line voltage will void the warranty e Make all connections to the instrument before applying power e Do not operate the instrument in ways not specified by this manual or by B amp K Precision Failure to comply with these precautions or with warnings elsewhere in this manual violates the safety standards of design manufacture and intended use of the instrument B amp K Precision assumes no liability for a customer s failure to comply with these requirements Category rating The IEC 61010 standard defines safety category ratings that specify the amount of electrical energy available and the voltage impulses that may occur on electrical conductors associated with these category ratings The category rating is a Roman numeral of Il Ill or IV This rating
3. agnetic fields Do not operate instrument if damaged If the instrument is damaged appears to be damaged or if any liquid chemical or other material gets on or inside the instrument remove the instrument s power cord remove the instrument from service label it as not to be operated and return the instrument to B amp K Precision for repair Notify B amp K Precision of the nature of any contamination of the instrument Clean the instrument only as instructed Do not clean the instrument its switches or its terminals with contact cleaners abrasives lubricants solvents acids bases or other such chemicals Clean the instrument only with a clean dry lint free cloth or as instructed in this manual Not for critical applications This instrument is not authorized for use in contact with the human body or for use as a component ina life support device or system Do not touch live circuits Instrument covers must not be removed by operating personnel Component replacement and internal adjustments must be made by qualified service trained maintenance personnel who are aware of the hazards involved when the instrument s covers and shields are removed Under certain conditions even with the power cord removed dangerous voltages may exist when the covers are removed To avoid injuries always disconnect the power cord from the instrument disconnect all other connections for example test leads computer interface cables etc di
4. e With this key the user can select the correct Ah range according to the battery under test This LED in ON to indicate that the user can select the Ah range This LED is ON when the unit locks to a particular Ah range set by the user This key selects the display either as No load voltage or balance Capacity Indicates that the Battery voltage is being displayed This LED is ON when remaining capacity is being displayed The test starts by pressing this key When this LED is ON and steady indicates that the unit is ready to conduct a test Test In Progress Reverse Polarity LED Display ve Cable ve Cable 10 This LED is ON for approx 3 sec when the battery test is carried out If the unit is connected to a battery in reverse polarity this LED will be ON Displays either battery voltage or battery Capacity percent Positive connecting cable with strain relief Negative connecting cable with strain relief 2 2 OPERATING PROCEDURE Follow the steps as outlined below 2 2 1 Connection Procedure Connect Battery Capacity Analyzer 600B to Battery Under Test BUT Connect the ve terminal of 600B to ve terminal of Battery Connect ve terminal of 600B to ve terminal of Battery The 600B will be powered by the BUT On Power up 600B performs a self test by turning on the 7 segments LEDs one after another amp finally flashing the version number Caution Do not connect the ve terminal of
5. is also accompanied 2 by a maximum voltage of the circuit to be tested which defines the voltage impulses expected and required insulation clearances These categories are Category CAT I Measurement instruments whose measurement inputs are not intended to be connected to the mains supply The voltages in the environment are typically derived from a limited energy transformer or a battery Category II CAT Il Measurement instruments whose measurement inputs are meant to be connected to the mains supply at a standard wall outlet or similar sources Example measurement environments are portable tools and household appliances Category III CAT 111 Measurement instruments whose measurement inputs are meant to be connected to the mains installation of a building Examples are measurements inside a building s circuit breaker panel or the wiring of permanently installed motors Category IV CAT IV Measurement instruments whose measurement inputs are meant to be connected to the primary power entering a building or other outdoor wiring Do not use this instrument in an electrical environment with a higher category rating than what is specified in this manual for this instrument You must ensure that each accessory you use with this instrument has a category rating equal to or higher than the instrument s category rating to maintain the instrument s category rating Failure to do so will lower the category rating of the measuring sys
6. p K Precision Corporation Printed in Taiwan 082615 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com
7. ports 12V storage type lead acid batteries with wide range of Ah capacity No external power Main or DC is required The unit works on BUT Battery Under Test 1 2 APPLICATIONS As the information age develops it is likely that the demand for UPS units will increase for use in hospitals offices labs etc It is expected that the importance of battery maintenance will increase along with increasing demand for UPS The 600B can be applicable for Automobile Service Stations UPS Manufacturing Maintenance and Field Servicing QC Department Battery Systems in Railways Telecommunications Ships Submarine 1 3 SPECIFICATIONS TECHNICAL 1 Capacity Display Range 0 to 100 2 Max Input Voltage 20 V 3 No Load Voltage Indication Accuracy 2 counts Caution Do not exceed max input voltage rating Doing so may cause fatal damage to the unit PHYSICAL 1 Dimensions WxHxD 2 91 x 10 44 x 2 12 74 x 265 1 x 54 mm 2 Weight 2 65 lbs 1 2 Kg NOTE Specifications and information are subject to change without notice Please visit www bkprecision com for the most current product information Section 2 Operation BK PRECISION 600B Battery Capacity Analyzer Polanty 12 Y Battery Only ADOQ OA OS FRONT PANEL CONTROLS Refer to the Front view of the unit 1 12 13 Ah Range Ah Select LED Ah Setting Saved LED Display Mode Battery Voltage Battery Capacity Load Test Ready Complet
8. scharge all circuits and verify there are no hazardous voltages present on any conductors by measurements with a properly operating voltage sensing device before touching any internal parts Verify the voltage sensing device is working properly before and after making the measurements by testing with known operating voltage sources and test for both DC and AC voltages Do not attempt any service or adjustment unless another person capable of rendering first aid and resuscitation is present Do not insert any object into an instrument s ventilation openings or other openings Servicing Do not substitute parts that are not approved by B amp K Precision or modify this instrument Return the instrument to B amp K Precision for service and repair to ensure that safety and performance features are maintained For continued safe use of the instrument e Do not place heavy objects on the instrument e Do not obstruct cooling air flow to the instrument e Do not place a hot soldering iron on the instrument Table of Contents Secon General DESC PUTO as 9 ALUN ROD CATION mtrs coartada 9 NPP GAO IN So naa 9 3 SPECIHCATION bo o ios 9 SECHON Z OPETI UON oina sare tada 10 22 OPERATING PROCEDURE ai 11 Service INFOMATION esseci E ET O O ER T 13 Limited One Year Wa a ROO ae 14 Section 1 General Description 1 1 INTRODUCTION B amp K Precision Battery Capacity Analyzer Model 600B measures the capacity left in a battery The model 600B sup
9. tem Do not operate in an explosive or flammable atmosphere Do not operate the instrument in the presence of flammable gases or vapors fumes or finely divided particulates The instrument is designed to be used in office type indoor environments Do not operate the instrument e Inthe presence of noxious corrosive or flammable fumes gases vapors chemicals or finely divided particulates e in relative humidity conditions outside the instrument s specifications e In environments where there is a danger of any liquid being spilled on the instrument or where any liquid can condense on the instrument e In air temperatures exceeding the specified operating temperatures e In atmospheric pressures outside the specified altitude limits or where the surrounding gas is not air e In environments with restricted cooling air flow even if the air temperatures are within specifications e Indirect sunlight This instrument is intended to be used in an indoor pollution degree 2 environment The operating temperature range is 0 C to 40 C and the operating humidity range is lt 95 relative humidity with no condensation allowed Measurements made by this instrument may be outside specifications if the instrument is used in non office type environments Such environments may include rapid temperature or humidity changes sunlight vibration and or mechanical shocks acoustic noise electrical noise strong electric fields or strong m
10. ue only after conduction of a test At power on a value of 0 is shown Hence Balance Capacity should be seen only after conduction of a test To observe No Load Battery Voltage press the Display Mode Key The display will show the No Load Battery Voltage 1 Do not connect Model 600B to a voltage source more than 20V 2 Do not connect the unit to a battery connected in circuit Limited One Year Warranty B amp K Precision Corp warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of one year from date of purchase B amp K Precision Corp will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed B amp K Precision Corp shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state 14 2015 B am