VPM-7704 User`s Manual

image

Contents

1. 00 90 E8 7A 7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 E mail Alert Sh Lh ne 3 1st SMTP server Enw 4st SMTP account name ES 1st sender s e mail Network Settings address Serial Port Settings 2nd SMTP server System Management 2nd SMTP account name Misc Network Settinos 2nd sender s e mail address Auto Warning Settings k 1st e mail address Event Settings 2nd e mail address Serial Event Settings Maintenance System Monitoring Save Configuration Restart The VPM 7704 can receive E mail Alert settings from configured VPort 700 devices Please refer to the VPort 700 series user s manual for more detailed information Maintenance There are four Maintenance sub categories Firmware Upgrade Configuration I mport Configuration Export and Load Factory Default Firmware Upgrade MO gt XN Total Solution for Industrial Device Networking www moxa com IP z 6 3 MAC Address 00 90 E8 AE FB C3 12346 Serial NO 1 Firmware 1 0 Build 10032611 Firmware Upgrade a 1 Warning Overview Basic Settings Note Upgrade firmware will discard your un saved configuration changes and restart the system Network Settings Select firmware file ji 7 _ Browse Serial Port Settings System Management Misc Network Settings Auto Warning Settings Maintenance Firmware Upgrade Configuration Import Configuration Export Load Factory Default Sy
2. When the Operation Mode for a particular port is set to Disabled that port will be disabled 3 3 4 Web Console Configuration The Web Console provides a convenient user friendly way to configure the VPM 7704 In this chapter we introduce the Web Console function groups and function definitions using the VPM 7704 to illustrate The following topics are covered in this chapter o o o o Opening Your Browser Basic Settings Network Settings Serial Port Settings Operation Modes Real COM Mode TCP Server Mode TCP Client Mode UDP Mode Pair Connection Mode Disabled Mode Vv VV VV Y Serial Parameters System Management gt Misc Network Settings gt Auto Warning Settings gt Maintenance System Monitoring gt Serial Status gt System Status Save Configuration gt Restart Restart System gt Restart Restart Ports VPM 7704 Web Console Configuration Opening Your Browser 1 Open your browser with the cookie function enabled To enable your browser for cookies right click on your desktop Internet Explorer icon select Properties click on the Security tab and then select the three Enable options as shown in the figure below Internet Options General Security content Connections Programs Advanced 21 xi Select a Web content zone to specify its security settings 90 Localintranet Trusted sites Restricted sites Internet This zone contains all Web sites y
3. Designated local port 2 5011 O Designated local port 3 5012 Designated local port 4 5013 Connection control Startup None la Data Packing Packing length o lo 1024 Delimiter 1 o0 wex Clenabie Delimiter 2 00 Hex L Enable Delimiter process Do Nothing Processed only when packing length is 0 Force transmit o o 65535 ms Or2 P3 Pa Apply the above settings to Hall ports TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional O min TCP connection is not closed due to an idle TCP connection 1 to 99 min The VPM 7704 automatically closes the TCP connection if there is no TCP activity for the given time Inactivity time Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional O ms TCP connection is not closed due to an idle serial line 0 65535 ms The VPM 7704 automatically closes the TCP connection if there is no serial data activity for the given time This parameter defines the maintenances status as Closed or Listen on the TCP connection The connection is closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time If the value of inactivity time is set to 0 the current TCP connection is maintained until connection dose request is received 4 11 VPM 7704 Web Console Configuration ATTENTION The Inactivity time should greater than
4. Serial Parameters System Management ignore jammed IP Enable Disable System Monitoring Allow driver control Enable Disable Save Configuration TCP port 14001 Restart Command port 965 Data Packing Packing length D 0 1024 Delimiter 1 00 ___ Hex Enable Delimiter 2 00 Hex LJ Enable Delimiter process Do Nothing b w Processed only when packing length is 0 Force transmit lo lo 65535 ms P1 Or2 P3 P4 Apply the above settings to EIAI ports TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional O min TCP connection is not closed due to an idle TCP connection 1 to 99 min The VPM 7704 automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed the VPM 7704 starts listening for another host s TCP connection Inactivity time Setting Factory Default Necessity O to 65535 ms 0 ms Optional O ms TCP connection is not closed due to an idle serial line 0 65535 ms The VPM 7704 automatically closes the TCP connection if there is no serial data activity for the given time After the connection is closed the VPM 7704 starts listening for another host s TCP connection This parameter defines the maintenances status as Closed or Listen on the TCP connection The connection is closed if there is no incoming or outgoing data through the serial port d
5. bits s 1000 ms s 8 3 ms Therefore you should set Force Transmit timeout to be larger than 8 3 ms Force Transmit timeout is specified in milliseconds and must be larger than 10 ms If the user wants to send the series of characters in a packet the serial device attached to the VPM 7704 should send characters with a time delay not larger than the Force Transmit timeout between characters and the total length of data must be smaller than or equal to the VPM 7704 s internal buffer size The serial communication buffer size of the VPM 7704 is 1 KB per port 4 10 VPM 7704 Web Console Configuration TCP Client Mode MOXA VPM 7704 VPM 7704_8698 Total Solution for Industrial Device Networking IP Serial NO 192 168 127 241 8698 www moxa con 00 90 E8 7A 7B 6C 1 0 Build 10030313 MAC Address Firmware Operation Modes Main Menu q Pon 1 Overview Basic Settings Operation mode TCP Client y Network Settings TCP alive check time 7 ko 99 min Serial Port Settings P Inactivity time K0 65535 ms Operation Modes EAN Ignore jammed IP OEnable O Disable Serial Parameters 1 r System Management Destination address 1 Port 4001 System Monitoring Destination address 2 Port 4001 Save Configuration Destination address 3 Pore 4001 Restart inn Destination address 4 pol Por 4001 Designated local porti 5010
6. e Built in 15 KV ESD protection for all serial signals 1 2 VPM 7704 Introduction Product Specifications Serial I nterface Serial Standards RS 232 422 485 Number of Ports 4 RJ45 connectors Serial Line Protection 15 KV ESD protection for all signals RS 485 Data Direction Control ADDC automatic data direction control Serial Communication Parameters Data Bits 5 6 7 8 Stop Bits 1 1 5 2 Parity None Even Odd Space Mark Flow Control DSR DTR and RTS CTS RS 232 only XON XOFF Baudrate 50 bps to 921 6 Kbps Serial Signal RS 232 TxD RxD RTS CTS DTR DSR DCD GND RS 422 Tx Tx Rx Rx GND RS 485 4w Tx Tx Rx Rx GND RS 485 2w Data Data GND Power Requirements Power Consumption Approx 5 W Physical Characteristics Housing Metal Dimensions 41 x 138 x 139 mm 1 61 x 5 43 x 5 47 in Weight 530 g Installation Mounted in a VPort 700 series slot 1 3 2 Getting Started This chapter includes information about installing your VPM 7704 device server The following topics are covered in this chapter O VPM 7704 Appearance O VPM 7704 LED Indicators O Adjustable Pull High low Resistors for the RS 485 Port VPM 7704 Getting Started VPM 7704 Appearance VPM 7704 LED Indicators The function of the LED indicators on the top panel of the VPM 7704 are described in the following table LED Name LED Color LED Function STAT Red Steady on
7. y Serial Port Settings 2 115200 none x 8 e 1 RTS CTS e Enable Rs 232 3 115200 x None v s x 1 we RTscTs y Enable x RS 232 y 4 115200 none 8 1 x rrsicTs Enabie y Rs 232 x tem Management ca S par 2 ea e a y e y ha tem Monitoring Baud rate Setting Factory Default Necessity 50 bps to 921600 bps 115200 bps Required The VPM 7704 supports baud rates from 50 bps to 921 6 Kbps Parity Setting Factory Default Necessity None Even Odd None Required Space Mark Data bits Setting Factory Default Necessity 5 6 7 8 8 Required When the user sets Data bits to 5 bits the stop bits setting will automatically change to 1 5 bits Stop bits Setting Factory Default Necessity 1 1 5 2 1 Required Stop bits will be set to 1 5 when Data bits is set to 5 bits Flow control Setting Factory Default Necessity None RTS CTS RTS CTS Required DTR DSR Xon Xoff FIFO Setting Factory Default Necessity Enable Disable Enable Required The VPM 7704 s serial ports provide a 16 byte FIFO both in the Tx and Rx directions Disable the FIFO setting when your serial device does not have a FIFO to prevent data loss during communication Interface Setting Factory Default Necessity RS 232 RS 422 RS 232 Required 2 wire RS 485 4 wire RS 485 4 19 VPM 7704 Web Console Configuration System Management There are three main configuration c
8. 00 90 E8 43 23 45 Finish 5 2 VPM 7704 Installing VPM 7704 Driver Double left click to launch NPort Windows Driver Manager The NPort Windows Driver Manager will help you easily install a virtual COM port on your computer Available COM ports and their mappings appear in blue until they are activated Activating a COM port saves the information in the host system registry and makes the COM port available for use The host computer will not have the ability to use the COM port until the COM ports are activated Click Apply and then dick Yes to activate the COM ports at this time or click No to activate the COM ports later MPori Windows Driver Manager File COM Mapping Configuration View Help E amp GE 5 Exit Add fFer Apply Undo vetting No COM Port Address 1 Address 2 COMS 192 168 127 241 950 966 Port1 COM9 192 168 127 241 951 967 Port2 COM10 192 168 127 241 952 968 Port3 COM11 192 168 127 241 953 969 Port4 Information e The modifiediremoved COM port must to be closed first Do you really want to apply the changes Configure the mapped COM ports For Real COM Mode to re configure the settings for a particular serial port on the VPM 7704 select the row corresponding to the desired port and then click the Setting button NPort Windows Driver Manager DER gt File COM Mapping Configuration View Help nod SSA Aaa Exit Add Remove Apply Undo Setting No COM Port Address 1 Address 2
9. 1 COMS 192 168 127 241 950 966 Port 2 COMI 192 168 127 241 951 967 Port2 192 168 127 241 52 E 4 COM11 192 168 127 241 953 969 Port4 Total COM Port 0 Click the Basic Settings tab Use the COM Number drop down list to select a COM number to be assigned to this serial port Select the Auto Enumerating COM Number for Selected Ports option to automatically assign available COM numbers in sequence to selected serial ports Note that ports that are in use will be labeled accordingly 5 3 VPM 7704 Installing VPM 7704 Driver COM Port Setting Port Number 1 Port s are Selected Basic Settings Advanced Settings Serial Parameters Security l IPv6 Settings Welatiria BOM Humbert slect e Pe COM Number COM current in use v X Cancel Click the Advanced Settings tab to modify Tx Mode FIFO and Flash Flush COM Port Setting Port Number 1 Port s are Selected Basic Settings Advanced Settings Serial Parameters Security IPv6 Settings The FIFO settings will overwrite the firmware setting NEUE HiPerfomance Y FIFO E nable v Network Timeout 3000 ms 500 20000 Auto Network Re Connection C Return Error If Network Is Unavailable Fast Flush Flush Local Buffer Only Help X Cancel Tx Mode Hi Performance is the default for Tx mode After the driver sends data to the VPM 7704 the driver immediately issues a Tx Empty response to the prog
10. Force transmit timeout To prevent the unintended loss of data due to the session getting disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed ATTENTION Inactivity time is active ONLY when TCP disconnect is set to Inactivity Time Ignore jammed IP Setting Factory Default Necessity No or Yes No Optional Previously when there are more than one hosts and the serial device is transmitting data if any one of the connected hosts is not responding it will wait until the data has been transmitted successfully before transmitting the second group of data to all hosts Now if you select Yes for Ignore jammed IP the host that is not responding will be ignored but the data will still be transmitted to the other hosts Packing length Setting Factory Default Necessity 0 to 1024 0 Optional Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once the VPM 7704 receives both delimiters through its
11. Hex LJ Enable Delimiter 2 loo Hex Enable Delimiter process Do Nothing jy Processed only when packing length is 0 Force transmit o ea 0 65535 ms pi P2 P3 P4 Apply the above settings to All ports TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Optional O min TCP connection is not closed due to an idle TCP connection 1 to 99 min The VPM 7704 automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed the VPM 7704 starts listening for another Real COM driver s connection from another host Max connection Setting Factory Default Necessity 1 2 3 4 1 Required Max connection is usually used when the user needs to receive data from different hosts simultaneously The factory default only allows 1 connection at a same When Max Connection is set to 1 the Real COM driver on the specific host has full control Max Connection 1 Allows only 1 host s Real COM driver to open the specific VPM 7704 serial port Max Connection 2 to 4 Allows 2 to 4 host s Real COM drivers to open the specific VPM 7704 serial port at the same time When multiple hosts Real COM drivers open the serial port at the same time the COM driver only provides a pure data tunnel without control ability That is this serial port parameter will use the firmware s settings
12. Port Serial Port Settings Destination address 1 14001 Operation Modes T ee 4 Destination address 2 14001 Serial Parameters A po Destination address 3 1 4001 System Management System Monitoring Destination address 4 3 4007 Save Configuration Local listen port 14001 Restart Data Packing Packing length 0 0 1024 Delimiter 1 o0 Hex LJ Enable Delimiter 2 00 Hex L Enable Delimiter process Do Nothing xj Processed only when packing length is 0 Force transmit 0 0 65535 ms P1 Or2 P3 P4 Apply the above settings to All ports Packing length Setting Factory Default Necessity 0 to 1024 0 Optional Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for O to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once the VPM 7704 receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the VPM 7704 s Ethernet port ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the
13. Power is on and the VPM 7704 is booting up Green Steady on Power is on and the VPM 7704 is functioning normally Off Power is off or power error condition exists Fault Red Blinking Indicates an LAN IP conflict or DHCP or BOOTP server did not respond properly Pi P2 orange Serial port is receiving data P3 P4 green Serial port is transmitting data off No data is being transmitted or received through the serial port Adjustable Pull High low Resistors for the RS 485 Port In some critical environments you may need to add termination resistors to prevent serial signal reflection When using termination resistors it is important to set the pull high low resistors correctly so that the electrical signal is not corrupted Since there is no resistor value that works for every environment DIP switches are used to specify the pull high low resistor values for each RS 485 port To set the pull high low resistors to 150 KQ make sure both of the assigned DIP switches are in the OFF position This is the default setting To set the pull high low resistors to 1 KQ make sure both of the assigned DIP switches are in the ON position Pull high low resistors for the RS 485 Port SWI SW2 SW3 SW4 DIP1 DIP2 DIP3 DIP4 ov famn Pull High Pull Low Terminator Reserved 4321 4321 4371 4321 ON 1 KQ 1 KQ 120 Q Reserved OFF default 150 KQ 150 KQ Reserved 2 2 VPM 7704 Getting Started ATTENTI
14. a server The syntax of mxdelsvr is mxdelsvr IP Address Example cd usr lib npreal2 driver mxdelsvr 192 168 3 4 The following actions are performed when executing mxdelsvr 1 Modify npreal2d cf 2 Remove the relevant tty ports in directory dev 3 Restart the driver If the IP address is not provided in the command line the program will list the installed servers and total ports on the screen You will need to choose a server from the list for deletion Removing Linux Driver Files A utility is included that will remove all driver files mapped tty ports and unload the driver To do this you only need to enter the directory usr lib npreal2 driver then execute mxuninst to uninstall the driver This program will perform the following actions Unload the driver Delete all files and directories in usr lib npreal2 Delete directory usr lib npreal2 Modify the system initializing script file Serial Port Pinouts RS 232 422 485 Port Pinouts A Port Pinout Diagrams PITT TA 1 8 Pin RE 233 aiee 2 wire 4 wire RS 485 RS 485 1 DSR 2 RTS TxD 3 GND GND GND 4 TxD TxD ad 5 RxD RxD Data 6 DCD RxD Data 7 CTS 8 DTR Compliance Notice CE Warming This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to ta
15. a a a S 4 2 Basic SeCttinGS As r e A AAA AAA AN A AAA RD AAA 4 3 Network Settings idas AAA O A A RA 4 4 Serial Port SQtelnS miii A iadseseessesvecesecsess 4 4 Operation MOSS oro A AA A AAA AAA 4 4 Real COM ME A AA 4 5 TEP Server MOE AAA 4 8 TCP Glen Mode A AAA di 4 11 UDP Moda tant aaa dese de ewan Mates Se 4 15 Pair Connection Mode frennen di 4 17 Disabled Mode AO AA PTEE NA a A A AA E A 4 18 Serial Parameters anio cade cannes celica liada arcada ltd add bata 4 18 System MONA MOE AA A A A adi id 4 20 Misc NetWork Settings o naa aa OI eds 4 20 AULOLWa ring Serting S a a a A A E AAA A AAA 4 21 MAINTENANCE ies eves ora La ALAN EOS OEA A ceded ee ante dw A Ea DNE A caters 4 24 SYStem MONO a Ii as 4 26 Serial SUS A dues di ced AA AA 4 26 SISMOS a e a los salas lao DAR ER EAT NAAN cantevedstsdetescdente 4 28 Save Configuration A A A A Aa t 4 29 Restart Restart NS 4 30 Restart Restart POrts sis ieietb a een teens a a aa aeaa A dida 4 30 5 Installing VPM 7704 Driver cccccccccccceeeeeeeeeeeeeeeeeeceueueueueueuauaueuauauauauaueueuaeaeusaeueueueueuauauauauauausueuguanenanass 5 1 OVIEDO 5 2 Installing a Virtual COM port ON your COMpUter eee nee 5 2 COM Map PIN Oka viata a eevee OR ARA ce ea ea cen wna ee eid OMA A A e e 5 2 Configure the mapped COM Ports visivssscsciscsivecsccccscccccccecsccecessscsessccscscaceseccestisestverssasrssaesesceiscicesieas 5 3 Linux Real TTY DAVOS o A A A 5 7 BASTE Proced eS A TE dees esi
16. independent of your own application program AP Application software that is based on the COM driver will receive a driver response of success when the software uses any of the Win32 API functions The firmware will only send the data back to the driver on the host Data will be sent first in first out when data comes into the VPM 7704 from the Ethernet interface 4 5 VPM 7704 Web Console Configuration ATTENTION When Max connection is set to 2 3 or 4 the VPM 7704 will be using a multi connection application i e 2 3 or 4 hosts are allowed access to the port at the same time When using a multi connection application the VPM 7704 will use the serial communication parameters set in the console All of the hosts connected to that port must use the same serial settings If one of the hosts opens the COM port with parameters that are different from the VPM 7704 s console setting data communication may not work properly Ignore jammed IP Setting Factory Default Necessity No or Yes No Optional Previously when Max connection gt 1 and the serial device is transmitting data if any one of the connected hosts is not responding it will wait until the data has been transmitted successfully before transmitting the second group of data to all hosts Now if you select Yes for Ignore jammed IP the host that is not responding will be ignored but the data will still be transmitted to the ot
17. port on the VPM 7704 to Real COM mode Install the Linux Real tty driver files on the host 3 Map the serial port to the host s tty port Hardware Setup Before proceeding with the software installation make sure you have completed the hardware installation After installing the hardware you must configure the operating mode of the serial port on your VPM 7704 to Real COM mode Installing Linux Real TTY Driver Files 1 Obtain the driver file from the included CD ROM or the Moxa website at http www moxa com 2 Log in to the console as a super user root 3 Execute cd to goto the root directory VPM 7704 Installing VPM 7704 Driver Copy the driver file npreal2xx tgz to the directory 5 Execute tar xvfz npreal2xx tgz to extract all files into the system Execute tmp moxa mxinst For RedHat AS ES WS and Fedora Corel append an extra argument as follows tmp moxa mxinst SP1 The shell script will install the driver files automatically 7 After installing the driver you will be able to see several files in the usr lib npreal2 driver folder gt mxaddsvr Add Server mapping tty port gt mxdelsvr Delete Server un mapping tty port gt mxloadsvr Reload Server gt mxmknod Create device node tty port gt mxrmnod Remove device node tty port gt mxuninst Remove tty port and driver files At this point you will be ready to map the NPort serial port to the system tty port Mapping TTY Ports Make sure tha
18. size of the serial data received is greater than 1 KB the VPM 7704 will automatically pack the data and send it to the Ethernet port However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Setting Factory Default Necessity Do nothing Do Nothing Optional Delimiter 1 Delimiter 2 Strip Delimiter 4 15 VPM 7704 Web Console Configuration Delimiter 1 or Delimiter 2 The data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Do nothing The data will be transmitted when the Delimiter is received Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional O Disables the force transmit timeout 1 to 65535 Forces the VPM 7704 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which the VPM 7704 fetches the serial data from its internal buffer If data is coming in through the serial port the VPM 7704 stores the data in the internal buffer The VPM 7704 transmits data stored i
19. transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Do nothing The data will be transmitted when the Delimiter is received Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional O Disables the force transmit timeout 1 to 65535 Forces the VPM 7704 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which the VPM 7704 fetches the serial data from its internal buffer If data is coming in through the serial port the VPM 7704 stores the data in the internal buffer The VPM 7704 transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the force transmit time interval reaches the time specified under Force Transmit timeout The force transmit timeout could be different for different applications but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200
20. with an incorrect password This can be configured to prompt e mail or SNMP trap notification IP address changed This event triggers when a user changes the VPM 7704 s IP address The VPM 7704 can send an e mail notification with the new IP address once the IP address changes before the VPM 7704 restarts If the VPM 7704 fails to send mail to the mail server after 15 seconds the device will abort the automated e mail notification and restart directly 4 22 VPM 7704 Web Console Configuration Serial Event Settings DA OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A 7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Serial Event Settings Main Menu 3 a Serial Port Event DCD Changed DSR Changed Basic Settings Port 1 Mail Trap C Mail Trap Network Settings Port2 Mail Trap O mail Trap Serial Port Settings Port3 Mail Trap C mail Trap System Management Port 4 Mail Trap Mail Trap Misc Network Settings All ports Mail Trap C Mait Trap Auto Warning Settings E mail Alert Maintenance System Monitoring Save Configuration Restart DCD changed This event triggers when the Data Carrier Detect DCD signal on the specified port changes which also indicates that the modem connection status has chan
21. 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A 7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Operation Modes Main Menu j Overview Port1 Basic Settings Operation mode Pair Connection Master y Network Settings TCP alive check time 7 ho 99 min Serial Port Settings ns 3 gt Destination address Port 4001 Operation Modes Serial Parameters Apply the above settings to P1 P2 P3 P4 System Management All pots tem Monitoring S Configuration Lisa TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Required O min TCP connection is not closed due to an idle TCP connection 1 to 99 min The VPM 7704 automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed the VPM 7704 starts listening for another host s TCP connection Destination IP address Setting Factory Default Necessity IP address range blank Optional e g 192 168 1 1 TCP port No 4001 Required The Pair Connection Master will contact the network host that has this IP address Data will be transmitted through the port No 4001 by default Note that you must configure the same TCP port No for the device server acting as the Pair Connection Slave Pair Connection Slave Mode When using Pair Connection Mode you must select Pair Connecti
22. 92 168 127 241 MAC Address 00 90 E8 7A 7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Operation Modes Main Menu J Port Operating Mode F Delimiter 1 Delimiter 2 Delimiter Process TA Overview a i Basic Settings TEF 0 00 Disable 00 Disable Do Nothing 0 Network Settings oa Max connection 1 Serial Port Settings or 0 00 Disable 00 Disable Do Nothing 0 A Max connection 1 Serial Parameters System Management 3 Real COM de aa o Mo Noisy System Monitoring Save Configuration i Seiad 0 00 Disable 00 Disable Do Nothing 0 Restart Max connection 1 To modify operation mode settings and advanced settings for a particular port click on the port number you want to configure under Operation Modes 4 4 VPM 7704 Web Console Configuration Real COM Mode MOXA Total Solution for Industrial Device Networking Wwww moxa con VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A 7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Operation Modes Main Menu A Port 1 Overview Basic Settings Operation mode RealCOM iv Network Settings TCP alive check time 7 Ko 99 min Serial Port Settings Mar tumiction My Operation Modes ES Ignore jammed IP Enable Disable Serial Parameters Allow driver contro Enable Disable System Management System Monitoring Save Configuration Data Packing Rasta Packing length lo ko 1024 Delimiter 1 00 y
23. Device Networking www moxa com IP 192 2 MAC Address 00 90 E8 7A7B 6C VPM 7704_8698 Serial NO Firmware 1 0 Build 10030313 Configuration Export Main Menu a A a Configuration Export Basic Settings Network Settings Serial Port Settings System Management Misc Network Settings Auto Warning Settings Maintenance Firmware Upgrade Configuration Import Configuration Export Load Factory Default System Monitoring Save Configuration Restart To export a configuration go to System Management gt Maintenance gt Configuration Export and click Download A standard download window will appear you will be able to save the configuration with the filename and in the location of your choice 4 25 VPM 7704 Web Console Configuration Load Factory Default DA OXN Total Solution for Industrial Device Networking www moxa com IP 192 168 127 241 MAC Address 00 90 E8 7A7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Load Factory Default Overview Click on Submit to reset all settings to the factory default values Basic Settings Network Settings Serial Port Settings Reset to Factory Default System Management Misc Network Settings Auto Warning Settings Maintenance Firmware Upgrade Configuration Import Configuration Export System Monitoring Save Configuration Restart This function will reset all of the VPM 7704 s settings t
24. ON Do not set the resistors to 1 KQ when using RS 232 Doing so will degrade the RS 232 signals and reduce the effective communication distance 2 3 3 Choosing the Proper Operation Mode In this chapter we describe the VPM 7704 s operation modes The options include an operation mode that uses a driver installed on the host computer and operation modes that rely on TCP IP socket programming concepts After choosing the proper operation mode for your application in this chapter refer to Chapter 4 for detailed configuration instructions The following topics are covered in this chapter Overview Real COM Mode TCP Server Mode TCP Client Mode UDP Mode Pair Connection Mode q0oaooaoaoooo Disabled Mode VPM 7704 Choosing the Proper Operation Mode Overview VPM 7704 device servers enable network operation of traditional RS 232 422 485 devices Device servers can bi directionally translate data between the serial and Ethernet formats allowing your computer to access manage and configure remote facilities and equipment over the Internet from anywhere in the world Traditional SCADA and data collection systems rely on serial ports RS 232 422 485 to collect data from various kinds of instruments Since VPM 7704 serial device servers enable network operation of instruments equipped with an RS 232 422 485 communication port your SCADA and data collection system will be able to access all instruments connected to a standard
25. Restart Ports under Restart and then select the ports you wish to restart Click Select All to select all the ports Click the Submit button to restart the selected ports 4 30 5 I nstalling VPM 7704 Driver The following topics are covered in this chapter O Overview O Installing a Virtual COM port on your computer gt COM Mapping gt Configure the mapped COM ports O Linux Real TTY Drivers gt Basic Procedures Hardware Setup Installing Linux Real TTY Driver Files Mapping TTY Ports Removing Mapped TTY Ports VV VV Y Removing Linux Driver Files VPM 7704 Installing VPM 7704 Driver Overview With a virtual RealCOM serial port it is possible to manage monitor and modify your VPM 7704 device from a remote location You can use the VPort 700 utility to easily configure your VPM 7704 device server over the network Once the VPort 700 utility is installed the most important step is to use COM Mapping to create a virtual COM port on your computer Please refer to the VPort 700 series user s manual for detailed VPort utility installation instructions Installing a Virtual COM port on your computer COM Mapping Run the VPort 700 series configurator and press the search button at the upper left to find all detectable VPort 700 series products m MOUS PPvci MO enes Crmenraior STATUS Broadcast Search Total Count 0 timeout 3sec Model _ _ IP Address MAC Address Proges YPort 704 192 168 127 253
26. TCP IP network regardless of whether the devices are used locally or at a remote site The VPM 7704 is a modular IP based network device that allows you to expand the number of serial ports for a host computer on demand As long as your host computer supports the TCP IP protocol you won t be limited by the host computer s bus limitation such as ISA or PCI or lack of drivers for various operating systems In addition to providing socket access the VPM 7704 also comes with a Real COM TTY driver that transmits all serial signals intact This means that your existing COM TTY based software can be preserved without needing to invest in additional software Three different Socket Modes are available TCP Server TCP Client and UDP Server Client The main difference between the TCP and UDP protocols is that TCP guarantees delivery of data by requiring the recipient to send an acknowledgement to the sender UDP does not require this type of verification making it possible to offer speedier delivery UDP also allows multicasting of data to groups of IP addresses Real COM Mode The VPM 7704 comes equipped with COM drivers that work with Windows systems and also TTY drivers for Linux systems The driver establishes a transparent connection between host and serial device by mapping the IP Port of the VPM 7704 s serial port to a local COM TTY port on the host computer This operation mode also supports up to 4 simultaneous connections so that multiple
27. VPM 7704 User s Manual First Edition August 2010 wWWw moxa com pr t MOXA 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited VPM 7704 User s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement Copyright Notice Copyright 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited Trademarks The MOXA logo is a registered trademark of Moxa Inc All other trademarks or registered marks in this manual belong to their respective manufacturers Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the information herein to correct such errors and these changes are incorpora
28. at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Setting Factory Default Necessity Do nothing Do Nothing Optional Delimiter 1 Delimiter 2 Strip Delimiter VPM 7704 Web Console Configuration Delimiter 1 or Delimiter 2 The data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Do nothing The data will be transmitted when the Delimiter is received Force transmit Setting Factory Default Necessity 0 to 65535 ms 0 ms Optional O Disables the force transmit timeout 1 to 65535 Forces the VPM 7704 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time interval during which the VPM 7704 fetches the serial data from its internal buffer If data is coming in through the serial port the VPM 7704 stores the data in the internal buffer The VPM 7704 transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the force transmit time interval reaches the time specified under Force Transmit timeout The force transmit timeout co
29. ategories under System Management Misc Network Settings Auto Warning Settings and Maintenance Misc Network Settings Accessible IP List MO gt YXA Total Solution for Industrial Device Networking Www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 VPM 7704_8698 Serial NO Firmware 1 0 Build 1003031 s Accessible List Main Menu 3 Overview Enable the accessible IP list Disable will allow all IP s connection request Basic Settings IP Address Netmask Network Settings Serial Port Settings System Management Misc Network Settings Accessible IP List SNMP System Log Settings Syslog Settings Auto Warning Settings Maintenance System Monitoring Save Configuration Restart 3 o fe sfo au ful 3 The VPM 7704 can receive the status of configured VPort 700 devices on the accessible IP address list Please refer to the VPort 700 series user s manual for more detailed information SNMP MOXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E87A7B 6C VPM 77 8698 Serial NO 8698 Firmware 1 0 Build 10030313 Main Menu 3 Es SNMP Read Write Settings Overview SNMP versions V1 V2c Basic Settings l u A ri i Network Settings l V1 V2c read community public V1 V2c write read we Serial Port Settings community private System Manageme
30. did not have a valid stop bit Parity Parity error indicates that the received data character did not match the parity selected Overrun The device was unable to hand received data to a hardware buffer because the input rate exceeded the device s ability to handle data Break Break interrupt indicates that the received data input was held low for longer than a full word transmission time interval A full word transmission time interval is defined as the total time to transmit the start data parity and stop bits 4 27 VPM 7704 Web Console Configuration Serial Status Serial Port Settings DA OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 P 492 168 127 241 MAC Address 00 90 E87A78 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Serial Port Settinas Overview Mute refresh Basic Settinos Network Settings Serial Port Settings port PY DataBits stop Bits Parity eer FIFO Interface System Management Rate RTSICTS XON XOFF DTRIDSR System Monitoring 1 118200 8 1 None ON OFF OFF Enable RS 232 Serial Status 2 115200 8 1 None ON OFF OFF Enable RS 232 Serial to Network Connections 3 115200 8 1 None ON OFF OFF Enable RS 232 Serial Port Status l 4 115200 8 1 None ON OFF OFF Enable RS 232 Serial Port Error Count Serial Port Settings System Status Save Configuration Restart The Serial Port Settings page displays the current status of each VPM 7704 seria
31. dustrial Device Networking www moxa com MAC Address 00 90 E8 7A 7B 6C Firmware 1 0 Build 10030313 Operation Modes Main Menu 3 Overview Port1 Basic Settings Operation mode Disable kd Network Settings P4 P2 P3 P4 Apply the above settings to Serial Port Settings All ports Operation Modes Serial Parameters System Management System Monitoring Sumt Save Configuration Restart When Operation mode is set to Disabled that particular port will be disabled Check the Apply the above settings to all serial ports to apply this setting to the other port Serial Parameters ATTENTI ON Check the serial communication parameters in your Serial Device s user s manual You should set up the VPM 7704 s serial parameters with the same communication parameters used by your serial devices 4 18 VPM 7704 Web Console Configuration Total Solution for Industrial Device Networking MOXA VPM 7704 VPM 7704_8698 192 168 127 241 8698 MAC Address Firmware Serial Parameters Www moxa com 00 90 E8 7A 7B 6C 1 0 Build 10030343 Main Menu j S Overview Port Alias Baud Rate Parity Bit Stop Bit Flow Control FIFO Interface AAA 1 115200 we None w 8 we 1 we rTsicTS y Enable e Rs 232
32. e Configuration System Status System Log MOXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A7B 6C VPM 7704_ Serial NO 8698 Firmware 1 0 Build 10030313 System Log Main Menu 3 System Log Overview Basic Settings Network Settings Serial Port Settings System Management System Monitoring Serial Status System Status Network Connections System Log Save Configuration Restart This option displays the system log You may click Select All to select the entire log if you wish to copy and paste the contents into a text file Save Configuration M OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP MAC Address D0 90 E8 7A78 6C VPM 7704_8698 Serial NO Firmware 1 0 Build 10030313 Save Configuration Main Menu a if you have submitted any configuration changes you must save the changes and restart the server before they Overview take effect Click Save to save the changes in the VPM 7704 s memory To restart the server go to Restart Basic Settings l System in the navigation panel Network Settings Serial Port Settings System Management System Monitoring Save Configuration Restart Click Save Configuration and then click Save to save your submitted configuration changes These configuration changes will take effect once the VPM 7704 is restarts If you do
33. ed in order to use this function Fast Flush only flushes the local buffer For some applications the user s program will use the Win32 PurgeComm function before it reads or writes data After a program uses this PurgeComm function the NPort driver continues to query the NPort s firmware several times to make sure no data is queued in the NPort s firmware buffer rather than just flushing the local buffer This design is used to satisfy some special considerations However it may take more time about several hundred milliseconds than a native COM1 due to the additional time spent communicating across the Ethernet connection This is why PurgeComm works significantly faster with native COM ports on the PC than with mapped COM ports on the VPM 7704 In order to accommodate other applications that require a faster response time the new NPort driver implements a new Fast Flush option By default this function is enabled If you have disabled Fast Flush and find that COM ports mapped to the VPM 7704 perform significantly slower than when using a native COM port try to verify if PurgeComm functions are used in your application If so try enabling the Fast Flush function and see if there is a significant improvement in performance The following figure shows the default Serial Parameters settings when the VPM 7704 is powered on However the program can redefine the serial parameters to different values after the program opens t
34. em Management Cacal tio 2000 03 19 07 09 28 System Monitoring sjetim upime D days 04h 53m 32s Save Configuration Serial port 1 115200 None 8 1 estar Serial port 2 115200 None 8 1 Serial port 3 115200 None 8 1 Serial port 4 115200 None 8 1 4 2 VPM 7704 Web Console Configuration Basic Settings MM OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A78 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Basic Settings Main Menu A Overview Server Settings Server name VP1 7704_8598 Network Settings Serial Port Settings Consol Settinigs a System Management System Monitoring HTTP console O Enable Disable Save Configuration Telnet console O Enable Disable Restart Auto refresh time l5 J 0 99 sec Server Settings Server name Setting Factory Default Necessity 1 to 39 characters model name _ Serial No Optional This option is useful for specifying the location or application of different VPM 7704 device servers Console Settings The Disable option for Web Console and Telnet Console is included for security reasons In some cases you may want to disable one or both of these console utilities as an extra precaution to prevent unauthorized users from accessing your VPM 7704 The factory default for both Web c
35. escription Startup None default A TCP connection will be established on startup and will remain active indefinitely Any Character None A TCP connection will be established when any character is received from the serial interface and will remain active indefinitely Any Character Inactivity Time A TCP connection will be established when any character is received from the serial interface and will be disconnected when the Inactivity time out is reached DSR On DSR Off A TCP connection will be established when a DSR On signal is received and will be disconnected when a DSR Off signal is received DSR On None A TCP connection will be established when a DSR On signal is received and will remain active indefinitely DCD On DCD Off A TCP connection will be established when a DCD On signal is received and will be disconnected when a DCD Off signal is received DCD On None A TCP connection will be established when a DCD On signal is received and will remain active indefinitely 4 14 VPM 7704 Web Console Configuration UDP Mode MOXA VPM 7704 Total Solution for Industrial Device Networking Www moxa con 192 168 127 241 MAC Address 00 90 E8 7A 7B 6C 1 0 Build 10030313 VPM 7704_8698 8698 Firmware Operation Modes Main Menu Port 1 Overview sic Settings Operation mode UDP x Network Settings Begin End
36. everse RealCOM mode Keep Connection is not supported X Cancel Click the I Pv6 Setting tab to configure the interface for Link Local address mapping When the global IPv6 address is used this function can be ignored When the Link Local IPv6 address is used users should select an interface for routing on interface index for address 1 The interface index for address 2 is for redundant COM mode which applies only to the CN 2600 series COM Port Setting Port Number 1 Port s are Selected pa Basic Settings Advanced Settings Serial Parameters Security IPv6 Settings Apply All Selected Port The Interface Index is for Link Local address mapping only Assign correct interface for your COM Port to be opened successfully Ignore the setting if the mapping address is NOT a link local one e g feS0 4 4 Interface Index for Address 1 Wiireless_LAN Intel R WiFi Link 5100 AGN Packet Scheduler Miniport vw Interface Index for Address 2 l Wried_LAN Intel R 82567LM Gigabit Network Connection Packet Sch w Help g X Cancel To save the configuration to a text file select Export from the COM Mapping menu You will then be able to import this configuration file to another host and use the same COM Mapping settings in the other host 5 6 VPM 7704 Installing VPM 7704 Driver 4 NPort Windows Driver Manager File COM Mapping Configuration View Help Fgh Add C
37. ged For example if the DCD signal changes to high this means that the local modem and remote modem have connected If the DCD signal changes to low this means that the connection is down This can prompt an e mail or SNMP trap notification DSR changed This event triggers when the Data Set Ready DSR signal has changes which also indicates that the data communication equipment s DCE power has changed For example a DSR signal change to high means that the DCE is powered on A DSR signal change to low means that the DCE is powered off This can prompt an e mail or SNMP trap notification Mail Setting Factory Default Necessity Enable Disable Disable Optional This feature helps the administrator manage the VPM 7704 If the check box is selected the VPM 7704 sends mail to pre defined mail boxes when the specified events such as Cold start Warm start or Authentication failure occur Trap Setting Factory Default Necessity Enable Disable Disable Optional This feature helps the administrator manage the VPM 7704 If the check box is selected the VPM 7704 sends an SNMP trap to a pre defined SNMP Trap server when the specified events such as Cold start Warm start or Authentication failure occur 4 23 VPM 7704 Web Console Configuration E mail Alert NM OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address
38. han Ex qm Remove Cti D Apply Undo No EG Setting CthC tress 1 1 168 127 241 BA Apply Cies 168 127 241 Bl Undo CtiZ Eao Import 168 127 241 Totsl COM Port 0 Ey Setting 950 966 Porti 951 367_ Port2 EEE 953 969 Port Address 2 The first way is with On line COM Mapping On line COM Mapping will check to make sure that the VPM 7704 is connected correctly to the network and then install the driver on the host computer The second way is with Off line COM Installation without first connecting the VPM 7704 to the network Off line COM Mapping can decrease the system integrator s effort by solving different field problems Via off line installation users can first process software installation for the host and then install the VPM 7704 to different fields Use the following procedure to map COM ports 1 On line COM Mapping Connect the VPM 7704 to the network gt Set the VPM 7704 to the proper IP address gt Map COMs to your host gt Apply Change 2 Off line COM Mapping Map COMs to your host gt Apply Change gt Connect the VPM 7704 to the network gt Configure the VPM 7704 s IP address Linux Real TTY Drivers Basic Procedures To map a VPM 7704 serial port to a Linux host s tty port follow these instructions 1 Set up the VPM 7704 After verifying that the IP configuration works and you can access the VPM 7704 by using ping telnet etc configure the desired serial
39. he port via the Win32 API COM Port Setting Port Number 1 Port s are Selected Basic Settings Advanced Settings Serial Parameters Security Pv6 Settings These options will be saved on registry and used on few applications such as serial printer driver In general cases you can ignore these settings Baud Rate 3600 v Parity None v Data Bits lB m Stop Bits 1 Flow Control None 7 Help E X Cancel Click the Security tab to configure security settings Select the Enable Data Encryption option to enable data to be encrypted when transmitted over the COM ports After selecting the encryption option select the Keep connection option to start encrypting COM port communications immediately without restarting the COM ports If your application will open close COM ports frequently and the VPM 7704 is only for one host you can enable this option to speed up the opening closing time However this will result in your host tying up the COM port so that other hosts cannot use it Select the Apply All Selected Ports option to enable the security settings to be applied to all COM ports 5 5 VPM 7704 Installing VPM 7704 Driver COM Port Setting Port Number 1 Port s are Selected Basic Settings Advanced Settings Serial Parameters Security IPv6 Settings Apply All Selected Ports C Enable Data Encryption Keep Connection In Redundant COM mode the security function is not supported In R
40. her hosts Allow driver control Setting Description Factory Default No or Yes No Required If max connection is greater than 1 VPM 7704 will ignore driver control commands from all connected hosts However if you set Allow driver control to YES control commands will be accepted Note that since VPM 7704 may get configuration changes from multiple hosts the most recent command received will take precedence Packing length Setting Factory Default Necessity 0 to 1024 0 Optional Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once the VPM 7704 receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the VPM 7704 s Ethernet port ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the VPM 7704 will automatically pack the data and send it to the Ethernet port To use the delimiter function you must
41. hosts can collect data from the same serial device at the same time ATTENTION The driver used for Real COM Mode comes with the NPort Windows Driver Manager The important point is that Real COM Mode allows users to continue using RS 232 422 485 serial communications software that was written for pure serial communications applications The driver intercepts data sent to the host s COM port packs it into a TCP IP packet and then redirects it through the host s Ethernet card At the other end of the connection the VPM 7704 accepts the Ethernet frame unpacks the TCP IP packet and then transparently sends it to the appropriate serial device attached to one of the VPM 7704 s serial ports ATTENTION Real COM Mode allows several hosts to obtain access control over the same VPM 7704 The driver that comes with your VPM 7704 controls host access to attached serial devices by checking the host s IP address Modify the Accessible IP Setting table when the legal IP address is required by your application 3 2 VPM 7704 Choosing the Proper Operation Mode TCP TCP Server Mode In TCP Server mode the VPM 7704 provides a unique IP Port address on a TCP IP network The VPM 7704 waits passively to be contacted by the host computer allowing the host computer to establish a connection with and get data from the serial device This operation mode also supports up to 4 simultaneous connections so that multiple hosts can collect data from
42. if any one of the connected hosts is not responding it will wait until the data has been transmitted successfully before transmitting the second group of data to all hosts Now if you select Yes for Ignore jammed IP the host that is not responding will be ignored but the data will still be transmitted to the other hosts Allow driver control Setting Factory Default Necessity No or Yes No Optional If max connection is greater than 1 the VPM 7704 will ignore driver control commands from all connected hosts However if you set Allow driver control to YES control commands will be accepted Note that since the VPM 7704 may get configuration changes from multiple hosts the most recent command received will take precedence Local TCP port Setting Factory Default Necessity 1 to 65535 4001 Required The TCP port that the VPM 7704 uses to listen to connections and that other devices must use to contact the VPM 7704 To avoid conflicts with well known TCP ports the default is set to 4001 Command port Setting Factory Default Necessity 1 to 65535 966 Optional The command port is a listen TCP port for IP Serial Lib commands from the host In order to prevent a TCP port conflict with other applications the user can adjust the command port to another port if needed IP Serial Lib will automatically check the Command Port on the VPM 7704 so the user does not
43. iguration Restart The system log function provides a method to record system status changes The VPM 7704 provides four event groups System Network Config and OpMode choose to record these events locally or remotely by selecting the associated check box If you use the remote log function please configure the syslog settings through the VPort 700 series main module Syslog Settings www moxa com MOXA Total Solution for Industrial Device Networking IP 192 168 127 241 Serial NO MAC Address 00 90 E8 7A7B 1 0 Build 10030313 Firmware Syslog Settings Main Menu J Syslog server 1 Overview Port destination 514 Basic Settings Syslog server 2 Network Settings Port destination 514 Serial Port Settings System Management Misc Network Settings Accessible IP List SNMP System Log Settings Auto Warning Settings Maintenance System Monitoring Save Configuration Restart The VPM 7704 can receive Syslog Settings from configured VPort 700 series devices Please refer to the VPort 700 series user s manual for more detailed information Auto Warning Settings Auto warnings alert you to unexpected events The right warning trigger conditions make it easier to manage and monitor the VPM 7704 effectively There are three Auto Warning Settings sub categories Event Settings Serial Event Settings and E mail Alert 4 21 VPM 7704 Web Console Configuration Eve
44. ke appropriate measures Federal Communications Commission Statement FCC This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Warming This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense
45. l port The status is automatically updated every five seconds System Status Click on System Status to display Network Connections and System log System Status Network Connections M OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 68 MAC Address _ 00 90 E8 7A 7B 6C VPM 7704_8698 Serial NO 3 Firmware 1 0 Build 10030313 Network Connections Main Menu 1 Overview s Mauto refresh Basic Settings Network Settings Protocol Recv Q Send Q Local Address Foreign Address State Serial Port Settings TCP 0 0 192 158 127 241 8000 LISTEN System Management TCP 0 0 192 168 127 241 4900 LISTEN System Monitoring TCP 0 0 192 168 127 241 14900 LISTEN Serial Status TCP 0 0 192 168 127 241 23 a LISTEN System Status TCP 0 0 192 168 127 241 80 sa LISTEN Network Connections TCP 0 0 192 168 127 241 950 LISTEN System Log TCP 0 0 192 168 127 241 951 LISTEN Save Configuration TCP 0 0 192 168 127 241 952 LISTEN Restart TCP 0 0 192 168 127 241 953 LISTEN TCP 0 0 192 168 127 241 966 z LISTEN TCP 0 0 192 168 127 241 967 LISTEN TCP 0 0 192 168 127 241 968 za LISTEN TCP 0 0 192 168 127 241 969 sa LISTEN TCP 0 0 192 168 127 241 80 192 168 127 1 4669 ESTAB TCP 0 0 192 168 127 241 80 192 168 127 1 4870 ESTAB TCP 0 0 192 158 127 241 80 192 168 127 1 4671 ESTAB Use Network Connections under System Status to view network connection information 4 28 VPM 7704 Web Consol
46. n the buffer via TCP IP but only if the internal buffer is full or if the force transmit time interval reaches the time specified under Force Transmit timeout The force transmit timeout could be different for different applications but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force Transmit timeout to be larger than 8 3 ms Force Transmit timeout is specified in milliseconds and must be larger than 10 ms If the user wants to send the series of characters in a packet the serial device attached to the VPM 7704 should send characters with a time delay not larger than the Force Transmit timeout between characters and the total length of data must be smaller than or equal to the VPM 7704 s internal buffer size The serial communication buffer size of the VPM 7704 is 1 KB per port Destination IP address 1 Setting Factory Default Necessity IP address range Begin Empty Required e g Begin End Empty 192 168 1 1 Port 4001 End 192 168 1 10 Destination IP address 2 3 4 Setting Factory Default Necessity IP address range Begin Empty Optional e g Begin 192 168 1 1 E
47. nd Empty End 192 168 1 10 Port 4001 Local listen port Setting Factory Default Necessity 1 to 65535 4001 Required The UDP port that the VPM 7704 listens to and that other devices must use to contact the VPM 7704 To avoid conflicts with well known UDP ports the default is set to 4001 4 16 VPM 7704 Web Console Configuration Pair Connection Mode Pair Connection Mode employs two VPM 7704 device servers in tandem and can be used to remove the 15 meter distance limitation imposed by the RS 232 interface One VPM 7704 is connected from its RS 232 port to the COM port of a PC or other type of computer such as a hand held PDA and the serial device is connected to the RS 232 port of the other VPM 7704 The two VPM 7704 device servers are then connected to each other with a cross over Ethernet cable both are connected to the same LAN or in amore advanced setup they communicate with each other over a WAN i e through one or more routers Pair Connection Mode transparently transfers both data and modem control signals although it cannot transmit the DCD signal between the two VPM 7704 device servers Pair Connection Master Mode When using Pair Connection Mode you must select Pair Connection Master Mode for the Operation mode of one of the VPM 7704 device servers In effect this VPM 7704 will be acting as a TCP client MO XAN Total Solution for Industrial Device Networking www moxa com VPM
48. need to configure the program Packing length Setting Factory Default Necessity 0 to 1024 0 Optional Default 0 The Delimiter Process will be followed regardless of the length of the data packet If the data length in bytes matches the configured value the data will be forced out The data length can be configured for 0 to 1024 bytes Set to 0 if you do not need to limit the length Delimiter 1 Setting Factory Default Necessity 00 to FF None Optional VPM 7704 Web Console Configuration Delimiter 2 Setting Factory Default Necessity 00 to FF None Optional Once the VPM 7704 receives both delimiters through its serial port it immediately packs all data currently in its buffer and sends it to the VPM 7704 s Ethernet port ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the VPM 7704 will automatically pack the data and send it to the Ethernet port However to use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Setting Factory Default Necessity Do nothing Do Nothing Optional Delimiter 1 Delimiter 2 Strip Delimiter Delimiter 1 or Delimiter 2 The data will be
49. not save your changes before restarting they will be discarded 4 29 VPM 7704 Web Console Configuration Restart Restart System M OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A 78 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Restart System J u Warning Overview Basic Settings Clicking Restart will disconnect all serial and Ethernet connections and reboot the VPM 7704 server Network Settings NOTE Unsaved configuration changes will be discarded and data currently in the middle of transmission may be lost Serial Port Settings System Management System Monitoring Resat Save Configuration Restart Restart Ports Use to Restart System under Restart and click the Restart button to restart the VPM 7704 If you do not save your configuration changes before you restart the system those changes will be lost Restart Restart Ports Total Solution for Industrial Device Networking www moxa com MOXA IP 192 7 MAC Address 00 90 3 7A78 6C VPM 7704_8698 Serial NO Firmware 1 0 Build 10030313 Restart Ports Mer eka E Restart the selected serial ports Overview Basic Settings Network Settings aerea Eor Serial Port Settings 1020304 System Management System Monitoring Save Configuration Restart Restart Syste Use to
50. nt Settings NA OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Event Settings Main Menu 3 System Event Overview Basic Settings Cold start Mail Trap Network Settings Warm start Mail Trap Serial Port Settings System Management Config Event Misc Network Settings Auto Warning Settings Console login auth fail Mail Trap E g IP changed Mail Serial Event Settings E mail Alert Maintenance System Monitoring Save Configuration Restart The VPM 7704 can provide status notifications through E mail or SNMP traps VPM 7704 system events such as a Cold start or a Warm start and a Console login authentication failure configuration event can all trigger both types of notification However an IP changed event can only trigger an e mail notification Cold start A cold start occurs when the system is turned on from a powered off state The VPM 7704 can automatically issue notification by e mail or SNMP trap after a cold start Warm start A warm start occurs when the system is restarted without turning the power off The VPM 7704 can automatically issue notification by e mail or SNMP trap after a warm start Console login authentication failure This event triggers when a user attempts to log in to the console or settings
51. nt V3 read write user name admin Misc Network Settings V3 read write i a ta No Auth Accessible IP List authentication mode V3 read write password System Log Settings V3 read write privacy mode disable V3 read write privacy Syslog Settings Auto Warning Settings Maintenance Trap Settings System Monitoring 1st Trap server IPiname L Save Configuration 1st Trap community public Restart 2nd Trap server IPiname 2nd Trap community public The VPM 7704 can receive SNMP status from configured VPort 700 series devices Please refer to the VPort 700 series user s manual for more detailed information 4 20 VPM 7704 Web Console Configuration System Log Settings www moxa com Total Solution for Industrial Device Networking 04 IP 04_8698 Serial NO MAC Address 00 90 E8 7A 7B 6C 1 0 Build 10030313 Firmware System Log Settings Event Local Remote Overview Summary 4 Group Log Log Basic Settings Network Settings System J System Cold Start System Warm Start Serial Port Settings Network DHCP Get IP Renew Mail Fail System Management Misc Network Settings gt Conti oO Login Fail IP Changed Config Changed Firmware Upgrade Config Import Config Accessible IP List g Export SNMP OpMode O Connect Disconnect Restart Syslog Settings Auto Warning Settings Maintenance System Monitoring Save Conf
52. o the factory default values System Monitoring There are two System Monitoring sub sections Serial Status and System Status Click on Serial Status to display Serial to Network Connections Serial Port Status Serial Port Error Count and Serial Port Settings Serial Status Serial Status Serial to Network Connections DA OXN Total Solution for Industrial Device Networking www moxa com 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A7B 6C 7704_8698 Serial NO 8698 Firmware 1 0 Build 1003 Serial to Network Connections Main Menu Overview VI Auto refresh Basic Settings Network Settings Serial Port Settings Port Operation Mode Connections System Management 1 RealCoM H JI H System Monitoring 2 RealCOM I i ll li Serial Status 3 RealCoM Il iI Y o RealCOM I ll H ll 1 Serial to Network Connections Serial Port Status Serial Port Error Count Serial Port Settings System Status Save Configuration Restart Use Serial to Network Connections under Serial Status to view the operation mode and status of each connection for each serial port All monitor functions refresh automatically every five seconds 4 26 VPM 7704 Web Console Configuration Serial Status Serial Port Status Total Solution for Industrial Device Networking www moxa com MOXA VPM 7704 Main Menu Overview Basic Settings Network Settings Serial Port Settings System Management Sy
53. on Slave Mode for the Operation mode of one of the VPM 7704 device servers In effect this VPM 7704 will be acting as a TCP server 4 17 VPM 7704 Web Console Configuration M OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A7B 6C VPM 7704_8698 Serial NO 3698 Firmware 1 0 Build 10030313 Operation Modes Main Menu 3 Port1 Overview Basic Settings Operation mode Pair Connection Slave lv Network Settings TCP alive check time Z _ o 99 min Serial Port S Serial Port Settings TCP port 4001 Operation Modes ala P1 P2 P3 Pa Serial Parameters Apply the above settings to System Management All ports System Monitoring Save Configuration Restart Submit TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Required O min TCP connection is not closed due to an idle TCP connection 1 to 99 min The VPM 7704 automatically closes the TCP connection if there is no TCP activity for the given time After the connection is closed the VPM 7704 starts listening for another host s TCP connection Local TCP port Setting Factory Default Necessity TCP port No e g 4001 4001 Required This Port No must be the same port No that you set up for the Pair Connection Master device server Disabled Mode MOXN Total Solution for In
54. onsole and Telnet console is Enable Web console Setting Factory Default Necessity Enable or Disable Enable Required Telnet console Setting Factory Default Necessity Enable or Disable Enable Required Auto refresh time Setting Factory Default Necessity O to 99 sec 5 sec Required 4 3 VPM 7704 Web Console Configuration Network Settings MOXA Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 127 241 MAC Address 00 90 E3 7A7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Network Settings Main Menu E IP settings Fixed Overview IP address 192 168 127 241 Basic Settings Netmask 255 255 255 0 Gateway Serial Port Settings DNS server 1 System Management DNS server 2 F System Monitoring Save Configuration Restart You only can assign a valid IP address to the VPM 7704 through the VPort 700 series module Refer to the VPort 700 Series User s Manual network setting session for more details Serial Port Settings There are two main configuration categories under Serial Port Settings Operation Modes and Serial parameters Operation Modes Click Operation Modes to display descriptions of operation mode settings and advanced settings for port 1 to 4 MO gt XN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 1
55. ou Breen haven t placed in other zones Security level For this zone Move the slider to set the security level for this zone Medium Safe browsing and still Functional P Prompts before downloading potentially unsafe content Unsigned ActiveX controls will not be downloaded Appropriate for most Internet sites Custom Level Default Level Security Settings 21x Settings Cookies Allow cookies that are stored on your computer O Disable O Enable O Prompt Allow per session cookies not stored Disable O Enable O Prompt fs Downloads rat File download O Disable O Enable RY Cant danland oe Reset to medium y Reset se custom settings coca 2 Since DHCP mode is the default IP setting of the VPort 700 series check the VPM 7704 s IP address and then type the IP address in the Address input box use the correct IP address if different from the default and press Enter MOXA VPM 7704 IP VPM 7704_ Total Solution for Industrial Device Networking Serial NO www moxa com 00 90 E8 7A 7B 6C 1 0 Build 10030313 MAC Address 192 168 127 241 8698 Firmware Welcome to VPM 7704 Model name VPM 7704 Serial No 8698 Basic Settings A a Firmware version 1 0 Build 10030313 Network Settings Ethernet IP address 192 168 127 241 PAS Ethernet MAC address 00 90 E8 7A 7B 6C Syst
56. ram Under Classical mode the driver will not send the Tx Empty response until after confirmation is received from the VPM 7704 s serial port This causes lower throughput Classical mode is recommended if you want to ensure that all data is sent out before further processing FIFO If FIFO is Disabled the VPM 7704 will transmit one byte each time the Tx FIFO becomes empty and an Rx interrupt will be generated for each incoming byte This will result in a faster response and lower throughput Network Timeout You can use this option to prevent blocking if the target NPort is unavailable Auto Network Re Connection With this option enabled the driver will repeatedly attempt to re establish the TCP connection if the VPM 7704 does not respond to background check alive packets 5 4 VPM 7704 Installing VPM 7704 Driver Return error if network is unavailable If this option is disabled the driver will not return any error even when a connection cannot be established to the VPM 7704 With this option enabled calling the Win32 Comm function will result in the error return code STATUS_NETWORK_UNREACHABLE when a connection cannot be established to the VPM 7704 This usually means that your host s network connection is down perhaps due to a cable being disconnected However if you can reach other network devices it may be that the VPM 7704 is not powered on or is disconnected Note that Auto Network Re Connection must be enabl
57. rial devices anywhere over a local LAN or the Internet The VPM 7704 ensures compatibility with network software that uses a standard network API Winsock or BSD Sockets by supporting TCP Server Mode TCP Client Mode and UDP Mode Thanks to the VPM 7704 s Real COM TTY drivers software that works with COM TTY ports can be set up to work over a TCP IP network in no time This convenient feature preserves your software investment and lets you enjoy the benefits of networking your serial devices instantly The VPM 7704 serial device servers support automatic IP configuration protocols DHCP BOOTP and manual configuration via the VPM 7704 s handy web browser console Either method offers quick and effective installation And with the VPM 7704 s Windows Utility installation of multiple devices is very straightforward since all system parameters can be stored and then copied to other device servers simultaneously Package Checklist Moxa VPM 7704 series products are shipped with the following items Standard Accessories e 1 VPM 7704 4 port serial device server e Product Warranty Statement NOTE Notify your sales representative if any of the above items is missing or damaged Product Features The VPM 7704 products offer the following features e Makes your serial devices Internet ready e Versatile socket operation modes including TCP Server TCP Client and UDP e 2or4 wire RS 485 with patented ADDC Automatic Data Direction Control
58. rval during which the VPM 7704 fetches the serial data from its internal buffer If data is coming in through the serial port the VPM 7704 stores the data in the internal buffer The VPM 7704 transmits data stored in the buffer via TCP IP but only if the internal buffer is full or if the force transmit time interval reaches the time specified under Force Transmit timeout The force transmit timeout could be different for different applications but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force Transmit timeout to be larger than 8 3 ms Force Transmit timeout is specified in milliseconds and must be larger than 10 ms If the user wants to send the series of characters in a packet the serial device attached to the VPM 7704 should send characters with a time delay not larger than the Force Transmit timeout between characters and the total length of data must be smaller than or equal to the VPM 7704 s internal buffer size The serial communication buffer size of the VPM 7704 is 1 KB per port Destination IP address 1 Setting Factory Default Necessity IP address or Domain None Required Addre
59. s Co ee EEE 5 7 Hardware Setup A cibua Giver ed elev ened de 5 7 Installing Linux Real TTY Driver FileS ooo iii end RIA 5 7 Mapping TIY POS na a A A 5 8 Removing Mapped TTY Ports iii A A c 5 9 Removing Linux Driver Files iii cece cccccececsdevevecesvaevsslesecuadeasbsvststatevsterstascedtceedcacecuaneaies 5 9 A Port Pinout DiagraMS comonnnnnnonococococacacaracanaranannnnnnnnnnnnn nan nn rnan rara n rara rara rana nananananananananarananencnrarararanananas A 1 SEPA ES oa ter a a a a de cdeadananeeincacsaadaaeesasargchannabensnensatuaaneeeasaanans vanes ater aiaddandededenadeneietated A 1 B Compliance Notice ccccccccccccccccecucueeeeeeeeeeueuseeueeeeeeeeaeeeueueueueuseeeeuaeeueuauauauauaeaeaeaeaeueauasseueuauauauauansuenenas B 1 1 Introduction Thank you for choosing the Moxa VPM 7704 The VPM 7704 makes it easy to enable serial operations on VPort 704 series modular industrial multi service gateways The VPort 7704 has four RS 232 422 485 ports The following topics are covered in this chapter O o o o Overview Package Checklist Product Features Product Specifications VPM 7704 Introduction Overview The VPM 7704 is designed to make your industrial serial devices Internet ready in an instant The compact size of the VPM 7704 makes it the ideal choice for connecting RS 232 422 485 serial devices such as PLCs meters and sensors to an IP based Ethernet LAN making it possible for your software to access se
60. serial port it immediately packs all data currently in its buffer and sends it to the VPM 7704 s Ethernet port ATTENTION Delimiter 2 is optional If left blank then Delimiter 1 alone trips clearing of the buffer If the size of the serial data received is greater than 1 KB the VPM 7704 will automatically pack the data and send it to the Ethernet port To use the delimiter function you must at least enable Delimiter 1 If Delimiter 1 is left blank and Delimiter 2 is enabled the delimiter function will not work properly Delimiter process Setting Factory Default Necessity Do nothing Do Nothing Optional Delimiter 1 Delimiter 2 Strip Delimiter Delimiter 1 or Delimiter 2 The data will be transmitted when an additional byte for Delimiter 1 or an additional 2 bytes for Delimiter 2 of data is received after receiving the Delimiter 4 12 VPM 7704 Web Console Configuration Strip Delimiter When the Delimiter is received the Delimiter is deleted i e stripped and the remaining data is transmitted Do nothing The data will be transmitted when the Delimiter is received Force transmit Setting Factory Default Necessity O to 65535 ms 0 ms Optional O Disables the force transmit timeout 1 to 65535 Forces the VPM 7704 s TCP IP protocol software to try to pack serial data received during the specified time into the same data frame This parameter defines the time inte
61. ss E g 192 168 1 1 Allows the VPM 7704 to connect actively to the remote host whose address is set by this parameter Destination IP address 2 3 4 Setting Factory Default Necessity IP address or Domain None Optional Address e g 192 168 1 1 Allows the VPM 7704 to connect actively to the remote host whose address is set by this parameter ATTENTION Up to 4 connections can be established between the VPM 7704 and hosts The connection speed or throughput may be slow if one of the four connections is slow since the slow connection will slow down the other 3 connections ATTENTION The Destination IP address parameter can use both IP address and Domain Name For some applications the user may need to send the data actively to the remote destination domain name 4 13 VPM 7704 Web Console Configuration Designated Local Port 1 2 3 4 Any Character None DSR ON DSR OFF DSR ON None DCD ON DCD OFF DCD ON None Setting Factory Default Necessity TCP Port No 5011 Port 1 Required 5012 Port 2 5013 Port 3 5014 Port 4 Connection control Setting Factory Default Necessity Startup None Startup None Required Any Character Inactivity Time The meaning of each of the above settings is given in the table below In general both the Connect condition and Disconnect condition are given Connect Disconnect D
62. stem Monitoring Serial Status Serial Port Status Serial Port Error Count Serial Port Settings System Status Save Configuration Restart VPM 7704_8698 IP Serial NO 192 168 127 241 8698 MAC Address 00 90 E3 7A7B 6C 1 0 Build 10030313 Firmware Serial Port Status 3 Auto refresh Port TxCnt RxCnt TxTotalCnt RxTotalCnt DSR DTR RTS CTS DCD 1 0 0 0 0 2 2 3 2 2 0 0 0 o 3 o 3 3 3 0 0 0 0 J J 4 4 0 a 0 o y gt Oo 3 J Serial to Network Connections Go to Serial Port Status under Serial Status to view the current status of each serial port Serial Status Serial Port Error Count MOXA Main Menu Overview Basic Settings Network Settings Serial Port Settings System Management System Monitoring Serial Status Serial Port Status Serial Port Error Count Serial Port Settings System Status Save Configuration Restart Serial to Network Connections Total Solution for Industrial Device Networking www moxa com IP Serial NO 192 168 127 241 8698 MAC Address 00 90 E8 7A7B 6C 1 0 Build 10030313 Firmware Serial Port Error Count Y Auto refresh ErrCnt Port Frame Parity Overrun Break 1 0 0 it 0 2 0 0 0 0 3 0 0 D 0 4 0 o 0 o The Serial Port Error Count page tracks the number and type of errors that have occurred on each port Error Type Definition Frame Framing error indicates that the received character
63. stem Monitoring Save Configuration Restart You can upgrade the VPM 7704 s firmware through the web console If you have made any changes to your configuration remember to save the configuration first before upgrading the firmware Please refer to Save Configuration later in this chapter to save your configuration Any unsaved changes will be discarded when the firmware is upgraded To upgrade the firmware simply enter the file name and click Submit The latest firmware can be downloaded from www moxa com 4 24 VPM 7704 Web Console Configuration Configuration mport M OXN Total Solution for Industrial Device Networking www moxa com VPM 7704 IP 192 168 33 13 MAC Address 00 90 E8 AE FB C3 VPM 7704_12346 Serial NO 12346 Firmware 1 0 Build 10032611 Configuration Import Main Menu J P P Configuration Import Overview Basic Settings Select configuration file Browse Network Settings Serial Port Settings System Management Misc Network Settings Auto Warning Settings Maintenance Firmware Upgrade Configuration Export Load Factory Default System Monitoring Save Configuration Restart To import a configuration go to System Management gt Maintenance gt Configuration Import Enter the configuration file path and click Submit The VPM 7704 s configuration settings will be updated with the configuration file Configuration Export NA Ox MN Total Solution for Industrial
64. t you set the operation mode of the desired VPM 7704 serial port to Real COM mode After logging in as a super user enter the directory usr lib npreal2 driver and then execute mxaddsvr to map the target NPort serial port to the host tty ports The syntax of mxaddsvr is as follows mxaddsvr NPort IP Address Total Ports Data port Cmd port The mxaddsvr command performs the following actions 1 Modifies npreal2d cf 2 Creates tty ports in directory dev with major amp minor number configured in npreal2d cf 3 Restarts the driver Mapping tty ports automatically To map tty ports automatically you may execute mxaddsvr with just the IP address and number of ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 4 In this example 4 tty ports will be added all with IP 192 168 3 4 with data ports from 950 to 953 and command ports from 966 to 969 Mapping tty ports manually To map tty ports manually you may execute mxaddsvr and manually specify the data and command ports as in the following example cd usr lib npreal2 driver mxaddsvr 192 168 3 4 4 4001 966 In this example 4 tty ports will be added all with IP 192 168 3 4 with data ports from 4001 to 4004 and command ports from 966 to 969 5 8 VPM 7704 Installing VPM 7704 Driver Removing Mapped TTY Ports After logging in as root enter the directory usr lib npreal2 driver and then execute mxdelsvr to delete
65. ted into new editions of the publication Technical Support Contact Information www moxa com support Moxa Americas Moxa China Shanghai office Toll free 1 888 669 2872 Toll free 800 820 5036 Tel 1 714 528 6777 Tel 86 21 5258 9955 Fax 1 714 528 6778 Fax 86 21 5258 5505 Moxa Europe Moxa Asia Pacific Tel 49 89 3 70 03 99 0 Tel 886 2 8919 1230 Fax 49 89 3 70 03 99 99 Fax 886 2 8919 1231 Table of Contents 1 A O 1 1 DI Sele a a i a a a a ene a a a aaas 1 2 Package Checklist mii A A aa aaa Eaa ia 1 2 Product RSS o o e A a A aaa e a e ec edi hate fete 1 2 Product Specificato S iii A A A RA AAA AAA 1 3 2 SA A O 2 1 VPM 7704 Ap Pana CO raja a sie AA A a A i n 2 2 VPM 7704 LEDTOdiCatorS fait deae tte tsi saGecudacctaenee nctateaetareruediinetectmuaunasduasneanstasuartetelacaiatatanetetedseaceeaes 2 2 Adjustable Pull High low Resistors for the RS 485 Port ccceeece cece eee eee eee eee ene eee 2 2 3 Choosing the Proper Operation Mode ocococococococacacanananannnncnnnnnnnnrnanancncnra rara rarararnnncanananananananananananinanes 3 1 OVERVIGW Ao 3 2 RealCOM MO SA tee 3 2 TEA Md AAA 3 3 TERM ARA AA 3 3 UDP Mode ii a a 3 3 Pair Connect O MOG a E de a a A etere rae As 3 3 Disabled MOG 6 nia AR A EA AS A A A A AAA AAA AA 3 3 4 Web Console Configuration ocmcococnnnnnononononanannnancancncnrarararararananananannnararananananancncncnrararararararnanancanananans 4 1 Opening Your Browser im na AAA A AAA oo
66. the same serial device at the same time Client Mode In TCP Client mode the VPM 7704 can actively establish a TCP connection to a pre defined host computer when serial data arrives After the data has been transferred the VPM 7704 can automatically disconnect from the host computer by using the TCP alive check time or Inactivity time settings Refer to chapter 4 for details UDP Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can multicast data from the serial device to multiple host computers and the serial device can also receive data from multiple host computers making this mode ideal for message display applications Pair Connection Mode Pair Connection Mode employs two VPM 7704 units in tandem and can be used to remove the 15 meter distance limitation imposed by the RS 232 interface One VPM 7704 is connected from its RS 232 port to the COM port of a PC or other type of computer such as a hand held PDA and the serial device is connected to the RS 232 port of the other VPM 7704 The two VPM 7704 units are then connected to each other with a cross over Ethernet cable both are connected to the same LAN or in a more advanced setup they communicate with each other over a WAN i e through one or more routers Pair Connection Mode transparently transfers both data and modem control signals although it cannot transmit the DCD signal between the two VPM 7704 device servers Disabled Mode
67. uld be different for different applications but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set Force Transmit timeout to be larger than 8 3 ms Force Transmit timeout is specified in milliseconds and must be larger than 10 ms If the user wants to send the series of characters in a packet the serial device attached to the VPM 7704 should send characters with a time delay not larger than the Force Transmit timeout between characters and the total length of data must be smaller than or equal to the VPM 7704 s internal buffer size The serial communication buffer size of the VPM 7704 is 1 KB per port VPM 7704 Web Console Configuration TCP Server Mode MOXA Total Solution for Industrial Device Networking WWw moxa con VPM 7704 IP 192 168 127 241 MAC Address 00 90 E8 7A 7B 6C VPM 7704_8698 Serial NO 8698 Firmware 1 0 Build 10030313 Operation Modes Main Menu J Port 1 Overview Basic Settings Operation mode TCP Server Y Network Settings TCP alive check time 7 0 99 min Serial Port Settings a Inactivity time 0 0 65535 ms Operation Modes lt Max connection 1 v
68. uring the specific Inactivity time If the inactivity time is set to O the current TCP connection is maintained until a connection close request is received ATTENTION The Inactivity time should greater than the Force transmit timeout To prevent the unintended loss of data due to a session getting disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed VPM 7704 Web Console Configuration Max Connection Setting Factory Default Necessity 1 2 3 4 1 Required Max Connection is usually used when the user needs to receive data from different hosts simultaneously The factory default only allows 1 connection at a time Max Connection 1 The VPM 7704 only allows 1 host to open a TCP connection to the specific serial port Max Connection 2 to 4 Allows 2 to 4 host s TCP connection requests to open the specific VPM 7704 serial port at the same time When multiple hosts establish a TCP connection to the specific serial port at the same time the VPM 7704 will duplicate the serial data and transmit it to all of the hosts Ethernet data is sent on a first in first out basis to the serial port when data comes into the VPM 7704 from the Ethernet interface Ignore jammed IP Setting Factory Default Necessity No or Yes No Optional Previously when Max connection gt 1 and the serial device is transmitting data