Home

SS101 Stormwater Sampler - Global Water Instrumentation, Inc.

image

Contents

1. SS101 A 2 BW Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com
2. 24 hr storm events before recharging is required SS101 1 BW Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com Product Description The Global Water SS101 Stormwater Sampler is easily installed near any storm water channel and can store water samples throughout a storm event The Sampler takes a discrete sample in one bottle based on rain fall accumulation and or rise in storm water level The Global Water SS101 Stormwater Sampler consists the following parts to ensure a successful sampling program Rugged rainproof lockable carrying enclosure Control panel enclosed logic regulator Peristaltic Sampling Pump Bypass plug Bottle cap with float switch and lead 2 5 gallon polyethylene sample bottle Rechargeable 5 AH gel cell paver Rain sensor on 15 cable Battery charger Water sensor on 15 cable Removeable sample pickup and debris strainer US Weather Bureau specified rain gauge with mounting bracket and screws 15 nylon reinforced polyeth ylene sample pickup hose 95101 2 BW Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com Installation SAMPLING LOCATION To meet specific permitting requirements sampling locations may need to be established and certified by a licensed professional refer to your permitting require
3. 3 insert end of peristaltic pump hose into hole in bottle cap and 4 plug the lead from the bottle cap into the Bottle SW socket on the control panel Ir ES DA a Place sample bottle into the Insert end of peristaltic pump hose Plug the lead from bottle cap into carrying enclosure into the hole in bottle cap Bottle SW socket The sampling unit can be secured from vandalism and strong winds by one of the following methods mount unit on post and lock closed e lock closed and chain rugged handle to a solid structure such as a tree post or building or e enclose and lock unit in a steel electrical box The sampling unit can be The sampling unit can be chained mounted onto a post to a solid structure S101 4 A Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com RAIN GAUGE Mount the Global Water Rain Gauge on a post Ideally the post should be 4 x 4 Install or use an existing post that is located conveniently for daily readings Do not mount the rain gauge near buildings or trees that may prevent rainfall from reaching the gauge The Rain Gauge should be mounted near eye level The top of the rain gauge should be higher than the top of the post To install the rain gauge 1 screw the mounting bracket onto the post making sure the bracket is level 2 insert the measuring tube in
4. plastic and glass sample bottles norprene tubing for the sampler pump bottle caps float switches removeable debris strainers sensors and pickup hose can be purchased from Global Water see Accessories section RAIN GAUGE The samplers Rain Gauge requires minimal maintenance Wash the Rain Gauge periodically with mild soap and warm water using a household bottle brush Do not use solvents or abrasives to clean the gauge and do not wash the gauge in a dishwasher Do not allow accumulated water to freeze in the gauge and avoid extremely rough usage BATTERY The battery will last without requiring recharging through several storm events If the pump grinds slowly this is an indication that the battery requires recharging We recommend fully recharging batteries approxi mately once per month In addition the battery should be recharged before any extended use To recharge the battery unfasten it from the control panel slide it out of the carrying case and unhook the cord from the battery terminals Then fasten the battery charger s disconnects onto the battery terminals and plug the charger into a wall socket Full recharge will take about 12 hours Additional batteries and battery chargers are available from Global Water see Accessories section To recharge the battery fasten the charger s disconnects onto the battery terminals and plug the charger into a wall socket ss101 10 EM Global Water Instrumentation Inc www gl
5. SS101 Stormwater Sampler User s Manual Global Water The Leader in Water Instrumentation Visit Our Complete Online Catalog www globalw com Call 800 876 1172 7 30 AM to 4 PM Pacific Time International US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com 11257 Coloma Road Gold River CA 95670 USA Level Flow Samplers Water Quality e Weather e Remote Monitoring Control Contents Specifications 1 Product Description 2 Installation 3 Operation 8 Maintenance 10 Troubleshooting 11 Global Water Warranty 11 Appendices Regulations Overview A 1 Accessories A 2 Sample Datasheets A 3 Specifications Sample Size Approximately 2 5 liters Sample Pump Flow Rate 1 000 ml per minute at 4 ft head Type Peristaltic Maximum Lift 22 Size 9 Lx 17 W x 22 H Operating Temperature 0 to 70 deg C Weight 22 Ibs Shipping Weight 24 Ibs Materials Enclosure Expanded UV protected PVC Bottle 4000 ml polyethylene Sample Tubing Polyethylene Logic Timer Controller CMOS Solid State fully potted in epoxy Water Sensors Solid State with a 15 cable Sample Hose 15 nylon reinforced 1 4 ID polyethylene flexible tubing sections with intake strainers Hoses may be extended as required using standard 1 4 tubing and fittings to a maximum of 50 Battery Rechargeable 5 AH Gel Cell Battery charger included Battery Life The battery will power the sampler for a minimum of four months including five
6. alw globalw com PICKUP HOSE AND WATER SENSOR The water sensor and pickup hose should be installed in a storm water discharge channel or stream that is appropriate for your sampling program The water sensor and pickup hose can be installed in the following manner 1 Securely insert a piece of rebar or similar mounting material into the center of the storm water discharge channel or stream The material should extend from the bottom of the channel at a distance appropriate for sensor installation see step 2 Avoid installation where water may pool 2a In a dry channel fasten the water sen sor and the end of the pickup hose onto the mounting material using tie wraps electri cal tape or hose clamps Ideally the pick up strainer should be placed at 1 2 the depth of flow during a storm event The water sensor should be tied just above the debris strainer in order to trigger a sample after the sample intake is submerged The water sensor and pickup hose should be situated to avoid contact with the channel bottom 2b In a stream fasten the end of the pick up hose onto the mounting material using Securely insert a piece of mounting material into the center of the channel tie wraps or hose clamps The pickup strainer should be submerged under water the channel bottom For stream sampling as opposed to dry channel sampling only the rain sensor will be used to trigger a sample 3 For dry channel sampling plug w
7. and service for a period of one year from date of shipment from factory Global Waters obligations under this warranty are limited to at Global Water s option i replacing or ii repairing any products determined to be defective In no case shall Global Water s liability exceed the product s original purchase price This warranty does not apply to any equipment that has been repaired or altered by anyone but Global Water or which has been subjected to misuse negligence or accident It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty merchantability SS101 11 BW Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com Regulations Overview CONSTRUCTION SITE STORM WATER SAMPLING GEORGIA S NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NPDES Permit Georgia s Department of Natural Resources General Permit No GAR100000 Authorization to Discharge Under the National Pollutant Discharge Elimination System Storm Water Discharges Associated with Construction Activity became effective August 1 2000 The permit strongly encourages the use of automated water sampling equipment Although it can be used for a variety of applications the Global Water SS101 Stormwater Sampler was specifically designed to meet Permit No GAR100000 s storm water sampling requirements The Permit requires that storm wa
8. ater sensor into Water Sensor socket on the control panel For stream sampling the bypass plug must be installed in the Water Sensor socket In a dry channel the water sensor should In a stream the pickup strainer should be tied just above the debris strainer be submerged under water SS101 7 EM Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com Operation SAMPLER Verify that the sampling unit rain gauge water and rain sensors and sampling pickup hose are installed cor rectly see previous section The Global Water SS101 Stormwater Sampler will function only if the battery plug is securely fastened into the appropriate socket on the control panel the bottle plug is inserted into the Bottle SW socket and either e both the rain sensor and water sensor are plugged into the appropriate sockets on the control panel i e both sensors must be submerged to trigger a sample or e the rain sensor or water sensor is plugged into its appropriate socket and the bypass plug is inserted into the remaining socket i e only the sensor that is plugged in must be submerged in order to trigger a sample Sample Now Water Sensor Rain Sensor Bypass Plug Rain Sensor ON OFF Sampler with both sensors used to Sampler with one sensor used to trigger a sample trigger a sample bypass plug in use Turn the sampling unit ON sw
9. d in a rain gauge and can trigger a sample at 0 5 1 0 and 2 0 inch rainfall events The water sensor is positioned in a storm water runoff channel where it will trigger a sample when runoff begins 1 This information is presented for general application overview only and should not be considered a replacement for fully reading and under standing Permit No GAR100000 Authorization to Discharge Under the National Pollutant Discharge Elimination System Storm Water Discharges Associated with Construction Activity 2 Storm water discharge sampling locations are identified for each site in a Comprehensive Monitoring Program prepared and certified by a pro fessional licensed by the State of Georgia 3 Based on average rainfall in Georgia it appears that there will be about 12 18 qualifying rainfall events per year 95101 A 1 A Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com Accessories Part Name Part Number Unit Removeable Battery BAT003 Each Battery Charger GB011 Each 1 Gallon Glass Sample Bottle GL066 Each Bottle Cap Float Switch 8003 Each Rain Gauge SS005 Each Pickup Hose SS017 Per ft Removeable Sample Pickup 8025 Each Norprene Peristaltic Pump Tubing SS060 Each Rain and Water Sensors with 15 Cable 3 Each 2 9 Gallon Plastic Sample Bottle WS001 Each Please contact Global Water or visit our website www globalw com for unit prices
10. ensor into the rain gauge at a specified rainfall accumulation 0 1 to 0 6 1 0 or 2 0 inches Securely hook the rain sensor s cable into the groove in the cylinder and place a tie wrap provided on the cable outside the groove to secure the installation Place the Rain Gauge funnel over the cylinder Insert the rain sensor s plug into the Rain Sensor socket on the control panel To trigger a sample when rainfall from 0 1 to 0 6 inch accumu lates insert the sensor at an appropriate depth into the measuring tube inside cylinder To trigger a sample when rainfall accumu lates at 1 0 or 2 0 inches insert the sensor at the appropriate depth in the outer cylinder For your reference 0 5 is clearly marked on the inside measuring tube and 1 0 and 2 0 are clear Hook the sensors cable into the Rain Gauge s groove ly marked on the outside cylinder securing a tie wrap outside the groove To trigger a sample when rain To trigger a sample when rain To trigger a sample when rain fall at 0 5 inch accumulates fall accumulates at 1 0 inch fall accumulates at 2 0 inch insert the sensor into the meas insert the sensor in the outer insert the sensor in the outer uring tube inside cylinder at cylinder at the depth as marked cylinder at the depth as marked the depth as marked 99101 6 BW Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail glob
11. itch is on the control panel and verify that the sampler is operating using the Sample Now switch The Sample Now switch can also be used to take manual samples If the Sample Now switch does not run the pump verify that the unit was installed and set up correctly see above and that the battery is recharged see Maintenance section If the unit still does not sample refer to the Trouble Shooting section The unit must be ON to take automatic samples The sampler will take approximately a 2 5 L sample The sampler has a backflush function that will clear the pickup hose and pickup strainer after a sample is complete The float switch in the bottle cap will turn off the sampler before the sample bottle overflows After a storm remove the sample bottle or transfer the sample to a small bottle for lab or turbidity meter analysis Then install an empty clean bottle SS101 8 EM Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com RAIN GAUGE The top funnel of the Rain Gauge catches the rain and delivers it to the measuring tube When over one inch of rain falls before the gauge is emptied water will spill out of the measuring tube into the outer cylinder Rainfall of less than one inch can be read directly from the measuring tube by standing the measuring tube on a level surface and reading the amount to the nearest 100th of an inch This
12. measurement can then be recorded in a rainfall log sample log provided For rainfall over one inch empty the measuring tube con taining the first 1 00 inch of rain Using the top funnel carefully pour water from the outer cylinder into the measuring tube if there is more than one inch of rain in the outer cylinder pour out the measuring tube and repeat Measure and record the total amount of rainfall being sure to count the first inch of rain that was in the measuring tube Place the measuring tube on a level surface and read the rainfall amount to the nearest 100th of an inch Georgia s NPDES Permit Sampling Requirements As required by the Permit samples from automatic samplers must be collected no later than the next business day after their accumulation Rainfall must be measured and recorded every 24 hours We recommend establishing a convenient time each day to check and collect if necessary samples and record rainfall SS101 9 EM Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com Maintenance SAMPLER The Global Water SS101 Stormwater Sampler requires minimal maintenance The sampler enclosure is rain proof and rugged Prevent exposure to extremely rough usage Routinely wipe the carrying case and control panel face rinse the pickup hose and debris strainer and wash the sample bottle with mild soap and warm water Additional
13. ments prior to establishing a sampling program An appropriate sampling location will most likely be e close to a storm water discharge channel or stream e situated so the rain gauge is away from trees and buildings and removed from public areas Georgia s NPDES Permit Sampling Location Requirements The Permit discusses sampling location requirements for the following construction projects e For all sites and common developments other than linear construction projects all waters into which storm water flows or all storm water channels or a combination thereof must be sampled e For linear construction projects all perennial and intermittent streams and other water bodies shown on a current 7 5 minute USGS topographic map and all other field verified streams storm water channels and water bodies must be sampled However representative streams water bodies and storm water channels may be sampled SS101 3 EM Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com SAMPLING UNIT The sampler should be placed upright it will not work if placed on its back or side within 15 feet from both the rain and water sensors see installation instructions below The battery lead should be securely fastened to the appropriate connection To secure the sample bottle 1 2 tighten the bottle cap place bottle into the sampler enclosure
14. obalw com 800 876 1172 gt US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com Troubleshooting If your Global Water SS101 Stormwater Sampler does not seem to be functioning properly Refer to the manual for proper setup check all connections and power supplies Manuals and additional technical information can be viewed on Global Waters web page www globalw com e Call Global Water for technical support at 800 876 1172 or 916 638 3429 many problems can be solved over the phone You can also fax 916 638 3270 or e mail globalw globalw com Global Water a detailed description of problems relating to your product e If your equipment needs to be returned to the factory for any reason please call Global Water to obtain a RMA number Return Material Authorization Do not return items without a RMA number displayed clear ly on the outside of the package When contacting Global Water for technical support please have the following information accessible Product name and model number Unit serial number Purchase Order Number if applicable Global Water invoice number Detailed description of problems relating to the product Global Water Warranty Our goal is to provide you with the finest water instrumentation at a reasonable price Our products are always fully supported and 100 guaranteed Global Water warrants that its products are free from defects in material and workmanship under normal use
15. ter samples be taken at construction sites between 5 and 250 acres as well as at smaller sites that are part of a common development within 45 minutes following either e the collection of a specified amount of rainfall after storm water runoff begins or e the beginning of storm water runoff after the collection of a specified amount of rainfall The Permit also requires that samples be taken at the following frequency e the first rainfall event greater than or equal to 0 5 inches in 24 hours e any rainfall event greater than or equal to 1 0 inch in 24 hours but only one 1 0 inch event per month needs to be sampled until final stabilization any rainfall event greater than or over 2 0 inches in 24 hours until final stabilization one rainfall event greater than or equal to 0 5 inches in 24 hours after final stabilization and e any rainfall event greater than or equal to 0 5 inches in 24 hour if Best Management Practices have not been properly designed installed or maintained in accordance with the Permit In addition rainfall must be measured and recorded once every 24 hours The SS101 uses a rain gauge that was developed and is manufactured to United States Weather Bureau specifications To meet the Permit s sampling requirements the Global Water SS101 uses two sensors to start an automatic sample the rain sensor and the water sensor The sensors can also be used to trigger samples independently The rain sensor is positione
16. to the rain gauge 3 slide the rain gauge into the mounting bracket 4 insert the rain sensor to desired rainfall depth see installation instructions below and 5 place the top funnel on the unit Install a 4 x 4 post that is located Screw the mounting bracket onto the post Slide the rain gauge into the conveniently for daily readings making sure the bracket is level mounting bracket Georgia s NPDES Permit Sampling Requirements According to the Permit runoff must be sampled for the following events First rainfall event greater than or equal to 0 5 inches in 24 hours Any rainfall event greater than or equal to 1 0 inches in 24 hours but only one event per month needs to be sampled until final stabilization Any rainfall event greater than or over 2 0 inches in 24 hours until final stabilization e One rainfall event greater than or equal to 0 5 inches in 24 hours after final stabilization and If Best Management Practices have not been properly designed installed or maintained in accordance with the Permit any rain fall event greater than or equal to 0 5 inches in 24 hours 99101 5 A Global Water Instrumentation Inc www globalw com 800 876 1172 US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com RAIN SENSOR The rain sensor is used to trigger a sample for specific amounts of rainfall accumulation Based on your application s require ments insert the tip of the rain s

Download Pdf Manuals