1. URCO Electric Urn Please read and keep these instructions These instructions cover the Burco C2T and C8T electric urns SKU s 444448536 amp 444448535 C8T C2T C8T SKU s 444448536 444448535 Glen Dimplex Professional Appliances Stoney Lane Prescot Merseyside L35 2XW Tel 0844 815 3755 www burco co uk INTRODUCTION To ensure you obtain full benefits from your new urn e Please read this instruction booklet carefully and follow all instructions e Ifyou are unsure of any aspect of the installation use or performance of your appliance please contact the after sales number shown on the back page SPECIFICATIONS Model Coo SKU Number 444448536 444448535 315mm Diameter 210mm 210mm Water volume 25 itre 7 5 litre Maximum draw off 2 2 lite 7 2 litre Weight pw SK Voltage 220 240V 50Hz Power rating 1840 2200W INSTALLATION Installation Requirements It is essential that this appliance is installed correctly Installation should comply with all local electrical and health and safety requirements WEEE directive registration no WEE DKOO59TT KI At end of unit life dispose of appliance and any replacement parts in a safe manner via a licenced waste handler Units are designed to be dismantled mmm Casy and recycling of all material is encouraged whenever practicable Before Connection to Power Supply Remove all packaging Check the appliance for damage
2. Remove the lid by turning anti clockwise and fill the urn with the desired amount of water Do not fill above the MAX capacity mark WARNING if the urn is overfilled there is a risk that boiling water will be ejected from around the lid Underfilling may cause the thermal cut out to operate and may shorten the element life Replace the lid turning clockwise to lock The urn is not suitable for heating liquids other than water or for heating water containing solids If the water is being heated for tea making make the tea in another container Controls The green power indicator will be illuminated whenever power is connected to the urn Turn the thermostat to the desired setting the amber heating indicator will be illuminated whenever the element is on This will go on and off as the the thermostat maintains the selected temperature Knob setting Approximate water temp C 43 C 56 C 69 C 82 C 92 C THIS URN IS NOT INTENDED TO CONTINUOUSLY BOIL WATER DUE TO THE HAZARDS OF STEAM AND WATER ESCAPING FROM UNDER THE LID If it is necessary to keep the water at an exact temperature use a thermometer to check Stir the water before taking the temperature and when the desired temperature has been reached turn the control knob slowly to the left until a click from the thermostat is heard The thermostat will then cycle on and off to maintain the temperature Serving The tap has two open positions one self holding
3. Report any damage immediately to the carrier or supplier Remove any protective plastic coating Any water in the urn is due to testing and is normal Check the available power supply corresponds to that shown on the appliance rating label Location This electric urn is for indoor use only Allow at least 100mm clearance from any wall Only use on a flat level surface that is adequate to support the weight when full of water Do not lift or move the urn when it contains hot water or when the mains lead is plugged in The appliance is only to be installed in locations where its use and maintenance is restricted to trained personnel The mains lead should reach from the mains socket without straining the connections Do not let the mains lead hang over the edge of the table or counter and keep it away from any hot surfaces Do not let the mains lead run across an open space Do not place the appliance where the mains lead could fall into a sink Do not place the appliance near a hot gas or electric burner Electrical Connection Fitting a plug The mains lead of this appliance will already be fitted with a BS1363 13A plug If the fuse has to be replaced use a 13 amp fuse complying with BS 1362 If the plug is not suitable for your socket then the plug must be cut off and disposed of safely An appropriate plug should be fitted as follows IMPORTANT The wires in the mains lead are coloured in accordance with the following code
4. Green and Yellow Earth Blue Neutral Brown Live The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black or blue The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red or brown Make sure that the connections are tight and that there are no loose strands of wire and no insulation trapped under the terminals Tighten the clamp in the plug making sure that it grips the outer covering of the cord If fitting a BS 1363 13A fused plug then fit a 13A fuse Tighten the plug cover securely If you are in any doubt consult a qualified electrician IMPORTANT replace the supply cord if damaged The supply cord may become warm when the appliance is in use WARNING THIS APPLIANCE MUST BE EARTHED Electrical connection 220 240V 50Hz 8 4 9 2A 1840 2200W Before Use Fill heat and discard the water twice before general use USER GUIDE TO AVOID BEING SCALDED KEEP HANDS AWAY FROM ANY STEAM FROM THE LID WHEN THE URN IS OPERATNG OR HAS JUST BEEN SWITCHED OFF TURN OFF THE POWER SUPPLY AND REMOVE THE PLUG WHEN NOT IN USE BEFORE CLEANING AND BEFORE REPLACING ANY PARTS Filling IMPORTANT always put water in the urn before switching on
5. e Appliances Stoney Lane Prescot Merseyside L35 2XW www burco co uk GLEN DIMPLEX PROFESSIONAL APPLIANCES 083193300 09 2011
6. i O 62462 TapOring S M O Neon green Ao 59214 Neonamber MT 6246 Thermostat O O GUARANTEE This electric urn is guaranteed against defective materials or faulty workmanship for a period of 12 months on labour and 36 months on parts This guarantee is given subject to the appliance being used in accordance with the instructions supplied and on the supply voltage marked on the rating label The guarantee is subject to fair wear and tear conditions The guarantee does not cover consequential damage arising out of any failure acceptable under guarantee nor does it cover damage resulting from misuse accident or unauthorised alterations to the appliance Proof of purchase will be required In any communication with the supplier or manufacturer quote the model and serial number marked on the appliance rating label This guarantee does not affect your statutory rights The products are intended for commercial use as detailed in these instructions The Company has a policy of continuous improvement in product quality and design The Company therefore reserves the right to change the specification at any time IMPORTANT any service call resulting from a lack of regular descaling is not covered by this guarantee and will be chargeable Customer helpline For spares and after sales service please contact Burco on T 0844 815 3755 F 0844 815 3748 E info gdha com Glen Dimplex Professional Appliances A Division of Glen Dimplex Hom
7. scale or sediment from the element and rinse thoroughly with clean water Descaling In hard water areas scale will form on the element and interior This will adversely affect the operation of the urn if allowed to accumulate Descale on a regular basis using a proprietary descaler recommended for stainless steel kettles Follow the instructions provided with the descaling product Scale build up can also cause the tap to drip If this should occur turn off the power supply and remove the plug Empty the urn and allow it to cool Unscrew the top of the tap from the body Wipe scrape and break the scale away from the rubber flexible seal and from the sealing surfaces inside the plastic body of the tap Reassemble in reverse order Trouble shooting No power to the Check supply socket is switched on appliance Check fuse and circuit breaker Check green power indicator is The appliance does illuminated not operate Thermostat or element Replace thermostat the element is not faulty intended to be replaced Bk WIRING DIAGRAM ELECTRIC CATERING URN THERMOSTAT L N INLET SUPPLY SOCKET ELEMENT Bk LIMIT HEATING INDICATOR ee aa AMBER Bk POWER CUT OUT INDICATOR THERMOSTAT GREEN 125C Wiring colour code Bk Black Bn Brown Bu Blue Gn Green W White SPARES LIST ALWAYS TURN OFF THE POWER SUPPLY AND REMOVE THE PLUG BEFORE REPLACING ANY PARTS 082620789 Tapassembly O M
8. so that the tap remains open and the other self closing so that the tap closes as soon as the lever is released Lift the lever up for the self holding position press the lever down for the self closing position Return the lever to the horizontal position to close the tap After use Turn the control knob to 0 and disconnect from the mains supply Water may be left in the urn when not in use for short periods but to maintain a supply of fresh water it should be emptied periodically and cleaned out ONakWNh WARNING only move the urn when it is disconnected and cool Protective cut out The heating element is fitted with a thermal cut out which protects the urn from damage if allowed to boil dry or switched on without water It is essential to keep the heating element free from scale to ensure correct operation of this cut out Scale can cause the cut out to operate when water is heating up normally If the cut out operates allow the urn to cool down drain out any water then press the red reset button situated under the base Cleaning ALWAYS TURN OFF THE POWER SUPPLY AND REMOVE THE PLUG BEFORE CLEANING ALLOW THE URN TO COOL THIS URN IS NOT WATERPROOF DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THE APPLIANCE OR USE A WATER JET IN THE VICINITY OF THE APPLIANCE Exterior Clean with water and detergent Do not use harsh abrasive cleaners as this could damage the surface finish Interior Brush any