TRP-C24H User`s Manual
Contents
1. DO1 DO05 D08 DO9 Output Enable 5 4 Read firmware version Syntax f Address of setting module 00 FF HEX description Command for reading module s version Response IDMODDDMMYY CHk cr MOD The module s model DD Date MM Month YY Year ID CHK cr Command Invalid EX Send command 01F Read the TRP C24H s version Response 01C24H090113 The TRP C24H s version date is 01 09 2013 16 5 5 Read the module s name CRE Address of setting module 00 FF HEX Syntax description Reading module s name Response NDNNNNNNNNN CHK cr NNNNNN The chars from 1 9 chars ID CHK cr Command Invalid EX Send command 01M Read the TRP C24H s name Response 01TRPC24H The module s name is TRPC24H 5 6 Reset Module Syntax description Address of setting module 00 FF HEX ey Garagem return Response IID CHK cr Command valid ID CHK cr Command Invalid EX Send Command 01RS Response 01 Command valid 17 5 7 Change Module s name Syntax description I Address of setting module 00 FF HEX NN 1 9 characters char Response IID CHK cr Command valid ID CHK cr Command Invalid EX Send Command 010123456789 Change Name Response 01 Command valid Send command 01M Read the TRP C24H s name Response 01123456789 The module s name is TRPC24H 5 8
2. ID C6 00 ID C6 C6 Function Code 00 Reserved code Example Send Command 01 46 OD 01 00 Response 01 46 OD 00 Error Response 01 C6 00 Error code 7 Pair Mode TRP C24H support pairing mode with the TRP C26H Applied to 16 digital channels input and 16 digital output with over the network without any driver with computer hardware All digital LED flashes in pairing mode until successfully paired will stop blinking TRP C24H sustained in connection automatically regardless of any party the power to re open or network disconnection to ensure normal transmission product application are as follows Pair Mode Counter Parking Brake _ _ gt in Ethernet Switch o p i l i 2 e 1 TRP C26H 16 DI TRP C24H 16 DO e 1 i e i I ia A re e e Fire detector Alarm 32 7 1 Parameter setting example Perform DSM utility to change the parameters TRP C24H parameter setting F2TRYCOM DSM 4 7 TRP Ethernet Series DSM IPC TRP C37 C37M C24H C26H C28H DSM Setting p Device Status List Setting Device Name MAC Address IP Mode Status 1 TRP C24H 00 0E C 00 00 99 Disable 192 168 1 1 502 Slave Connected DMa CEE Search Network Setting Serial Port Modbus Setting Device Name TRP C24H Module Name TFC IP Search z MAC Address o0 0E C 00 00 99 Netnask 255 255 2550 Device Setup aay Disable ER 19216613 C Server Mas
3. Set LED operating mode Syntax description Address of setting module 00 FF HEX C E Set the module s LED operating mode A 1 Turn off all LEDS when Output Enable ON A 0 Turn on all LEDS when Output Enable OFF C Carriage return Response IDNN CHK cr NN ON or OFF Command valid ID CHK cr Command Invalid EX Send command 01LED1 Turn off all LED when Channel Enable ON Response 010FF Command valid 18 5 9 Enable Watchdog Syntax Address of setting module 00 FF HEX description Carriage return e pe Response IID CHK cr Command valid ID CHK cr Command Invalid EX Send Command 01WE Enable Watchdog Response 01 Command valid The user can not change the digital output state when watchdog enable this mode will keep until the watchdog disable When the watchdog enable digital output into safe mode There are 3 ways you can set the safe mode command WEB DSM 5 10 Disable Watchdog Syntax description h Address of setting module 00 FF HEX Carriage return Response IID CHK cr Command valid ID CHK cr Command Invalid EX Send Command 01WD Watchdog Disable Response 01 Command valid 19 5 11 Read Watchdog State Syntax description ET Address of setting module 00 FF HEX Response DWN CHK cr N E Enable N D Disable ID CHK cr Command Invalid EX Send
4. Command 01WR Read Watchdog state Response 01WE Watchdog Enable 5 12 Read Power on Safe Mode Syntax i Address of setting module 00 FF HEX description Read power on safe mode status V P Power on V S Safe mode Response IDLLHH CHK cr HH DO15 DO8 LL DO7 DO0 ID CHK cr Command Invalid EX Send Command 014P Read Power on output status Response 011234 Command valid 20 5 13 Set the digital output status Power on Save Mode status Syntax description ET Address of setting module 00 FF HEX Save the current digital output is save or power on mode V P Power on V S Safe mode Carriage return Response IID CHK cr Command valid ID CHK cr Command Invalid EX Send Command 010A33 Digital output DOO DO7 11001100 Send Command 010B17 Digital output DO8 DOF 10001110 Send Command 015P Save Power on Send Command 014P Read Power on Response 013317 21 5 14 Read Module ID and Model Name Syntax When TCP connected get online module ID and Model Name description cr Carriage return Response IDName CHK cr ID Decimal Name Model Name ID CHK cr Command Invalid EX Send Command When TCP connected get online module ID and model name Response 001TRP C24H 5 15 Back to Factory is We Syntax E T n ey f Cariageretu
5. DSM IPC TRP C37 C37M C24H C26H C28H DSM Setting p Device Status List Setting _ Device Name MAC Address 1 TRP C26H 00 0E C6 00 00 9B Disable 19216812 502 Master Connected TT RES Network Setting Serial Port Modbus Setting Device Name TRE C26H Module Name FRPCER IP Search MAC Address o0 0E C6 00 00 98 Netmask 255 255 255 0 Gateway 192 168 1 3 168 95 1 1 Device Setup 192 168 1 2 Web Browser Data listening port ps snsmit Timer 10 C ChentSlave Heart Beat Disable S Restore UID Range ChentSlave IP Address Port zi Reboot To p pen pz To p poso f TCPKeep Alive 7 z To 5 pooo p Cd F F Pop P nono Fe CE to p po p Data Packet Type Management Packet Type TE F T l ss m ES E EE ET T pp fp 0 0 0 p M UDP d r Auto connect M Broadcast F fp 6 0 0 p after reboot I Multicast V TCP CE pars p Device Setup Network Setting Serial Port Modbus Setting m Serial Port Setting Digital Output Status tina Baud rate 9600 Digital Input Status p Digital Input CH1 Data bits fe x BS Digital Input CH2 Parity ione gt Digital Input CH3 Digital Input CH4 Stop bits 1 nr Ve Digital Input CH5 Flow Control None lt Digital Input CH6 Digital Input CH7 r Modbus Setting Slave ID Digital Input CHS Power On Mode Output pp Safe On Mode Output igital Input CH9 LED Display Panel Setting Off
6. Example Send Command 01 46 07 00 Read Firmware Version Response 01 46 07 13 01 10 00 Firmware Version 01 10 2013 Error Response 01 C6 00 Error code 30 6 10 Enable Disable watchdog ID 46 OB WS 00 ID Address of setting module 1 247 46 Function Code 0B Setting Watchdog Status WS 00 Watchdog Disable ws WS 01 Watchdog Enable 00 Reserved code ID 46 OB 00 00 ID 46 OB 00 Command valid ID C6 00 ID C6 C 6 Function Code 00 Reserved code Example Send Command 01 46 OB 01 00 Watchdog Enable Response 01 46 0B 00 Command valid Error Response 01 C6 00 Error code 6 11 Read watchdog status ID 46 OC 00 ID Address of setting module 1 247 46 Function Code C Read watchdog status 00 Reserved code ID 46 OC Module command line ID 46 OC WT WT 00 Watchdog Disable WT 01 Watchdog Enable ID C6 00 ID C6 C 6 Function Code 00 Reserved code Example Send Command 01 46 OC 00 Read watchdog status Response 01 46 OC 01 Watchdog enable Error Response 01 C6 00 Error code 31 6 12 Set up LED ON OFF ID 46 OD OS 00 ID Address of setting module 1 247 46 Function Code OD Set Up LED Status Value S 0 Turn on all LED when DIO enable off 0S S 1 Turn off all LED when DIO enable on 00 Reserved code ID 46 OD 00 ID 46 0D Command valid
7. zj Pre a TEE Digital Input CH10 a e Zi Digital Input CH11 Pisital Input CH12 Digital Input CH13 Digital Input CH14 Digital Input CH15 Digital Input CH16 WIT Save Load 34 8 Application C S Motor ON OFF i IN Lamp ON OFF E e Digital Input Alarm Security ES 16 Channel Open Colloctor 4 Ethernet 4 Modbus RTU ASCII or TRP ASCII TRP C24H Host PC 35
8. Code ID Address Data CHK cr How to calculate the checksum 1 Calculate all characters of the command string to get the ASCII sum except the character return 2 Mask the sum of string with OFFH Example Send the command is 06M Sum of string is 0 6 M 24H 30H 4D A1H The checksum and CHK A1 Response string with checksum is A1 TRP ASCII ease of use TRP ASCII integration to develop their own software such as VB VC ID5V CHK cr Store Power on Save on mode CHK cr Read Module ID and mode name CHK cr Back to factory 13 5 1 Setting module configuration IDNNPPOODD CHk cr Le l First leading code CRE Address of setting module 00 FF HEX Syntax Description New address of setting from 00 FF HEX ppp The Digital I O module type define to 40 C Gamiageretum return Response ID CHK cr Command valid ID CHK cr Command Invalid DD Data Format w oe oo oo eee o Function Checksum 0 Disable 1 Enable EX Send command 0103400000 New ID is 03 D I O type is 40 Checksum setting disable is 00 Response 01 5 2 Digital Output Data IDPPDD CHK cr First leading code Syntax Address of setting module 00 FF HEX description D I O type 0A 00 DOO DO7 low byte data Multi Channel 0B high byte data D8 D15 Multi Channel 1L AL DOO DO7 low byte dat
9. N Mode Output 0000 FFFF Digital output state when watchdog enable Digital Output Status Display last stored in the memory of the digital output state Digital Input Status This feature is only available to TRP C26H and TRP C28H Display last stored in the memory of the digital input state Digital Input CH1 CH16 Display last stored in the memory of the digital input counter value 10 This feature is only available to TRP C26H and TRP C28H Submit Save the setting value to memory Save Save the setting value to external log file Load Load the setting value to external log file Upgrade Upgrade the TRP C24H firmware 4 4 Using the WEB Server mode The Web Server can be used to configure the TRP C24H from any web browser software such as I E In Internet Explorer type the IP Address of the TRP C24H into the address field and press the Enter key The following window will appear Example If TRP C24H IP is 192 168 1 1 Please Input the 192 168 1 1 then enters at web address the web page will appear He Edt View Favorites Tool Help 5 Om Ord A Alps frre Ov STB Address el http 192 168 1 1 san TRP C2 4H Isolated 16 CH O C Modbus TCP WDT inside iad TRP C24H Setting Network Settings 4 5 TRPCOM Test Utility The TRPCOM test utility may help to use the debugging program development phase the user can find this software in our CD internal directory copied
10. TRP C24H 16 channels isolated digital output Open Collector Modbus TCP module User s Manual Printed Sep 2014 Rev 1 4 Trycom Technology Co Ltd No 35 Zhongxing Rd Guishan Township Taoyuan County 333 Taiwan Tel 886 3 350 3351 Fax 886 3 350 3352 Web www trycom com tw Copyright Copyright Notice The information in this manual is subject to change without notice to improve reliability design and function and does not represent a commitment on the part manufacturer No part of this manual may be reproduced copied or transmitted in any form without prior written permission by the manufacturer Products mentioned in this manual are mentioned for identification purposes only In this manual product names appearing may or may not be registered trademarks of their respective companies or copyright 1 Introduction The TRP C24H is an Isolated open collector digital outputs Modbus TCP Module It provides 16 channels output open collector signal 100mA to driven your devices on network It supports 3 communication Protocols TRP ASCII Modbus RTU ASCII It can be easy and convenient to use application supports Modbus Software engineers can use the TRP ASCII or Modbus RTU ASCII command set quickly and easily integrated into the self development program such as Microsoft VB VC The TRP C24H built in independent IP WEB browsing more convenient to rewrite the configuration and collect information through computers table
11. a Single Channel L 0 7 BL high byte dataD8 D15 Single Channel L 0 7 DD 00 FF Milti Channel DD 00 or 01 Single Channel Response gt CHK cr Command valid ID CHK cr Parameter invalid Command data error ID CHK cr Command Invalid Multi Channel mode Output control for one BYTE EX Send command 010A12 Data 12 DO0 DO7 10000100 1 Output Enable Response gt Command valid EX Send command 010B34 Data 34 DO8 DO15 110000010 1 Output Enable Response gt Command valid EX Send command 01000G Data 0G Data error Response 0 Parameter error Single Channel mode Output control for one BIT EX Send command 011001 Data 01 DO0 1 1 Output Enable Response gt Command valid Send command 011201 Data 01 DO2 1 14 Output Enable Response gt Command valid Send command 01B301 Data 00 DO11 1 1 Output Enable Response gt Command valid 15 5 3 Read digital input output status CON M Address of setting module 00 FF HEX Syntax description ee o Read digital output status Carriage return CE Response IDLLHH CHK cr LL DO0 DO7 status HH DO8 DO15 status ID CHK cr Command Invalid EX Send command 016 Read digital output status Response 011234
12. ame into the corresponding IP address Transmit Timer This feature is only available to Serial Server TRP C37 and TRP C37M Maximum Connection 1 16 The function allows the user to configure the TRP C24H in Server mode adjust 1 16 TCP client host connections TCP Keep Alive 1 7 Minute When TRP C24H in Server or Client mode the TRP C24H without data over the 1 7 Min setting value The TRP C24H will be disconnecting TCP port New Password 1234 It only accepts value from 1000 9999 integer if input the wrong password over 5 times the WEB Page will lock until the TRP C24H re boot Firmware Version ABC Slave ID 1 255 ID performs MODBUS RTU ASCII and TRP ASCII will use to address LED Display Panel Setting ON OFF The setting will turn on all panels LED or Turn off panel LED Polling Setting High Low Digital High Low potential settings Applies only TRP C26H C28H System Mode Power ON Mode Digital output state wnen the TRP C24H Power On Save ON Mode The digital output state when the TRP C24H is working Once this mode is set the digital output state cannot be rewritten Pair Mode It can be used as a remote manual remote control when the TRP C24H 16 DO and TRP C26H 16 CH DI TRP C28H 4 D I O with TRP C28H 4 D O Without any driver Trycom Checksum setting Disable Enable TRP ASCII command used bit checksum Power On Mode Output 0000 FFFF Digital output state when TRP C24H Boot Save O
13. cator DIN Rail and panel mount support Dual power input select from screw terminal or DC Jack 1 2Specification Power Input Voltage DC 10V to 30V Protocol TRP ASCII and Modbus RTU ASCII Digital output maximum voltage 30V Digital output maximum current 100mA Digital output isolation 3750Vrms Communication interface Ethernet RJ45 Configuration mode Trycom Device Manager WEB settings Matching remote control with TRP C26H Heart Beat TCP Port sent string every 5 seconds TCP Maximum Connection 1 16 Module ID 1 255 Connection type Screw terminal for maximum AWG 12 wire Power supply Screw terminal or external DC adapter Power consumption 240mA 12V Operating environment 0 to 50 C Storage temperature 10 to 70 C Humidity 10 90 Non condensing Dimension 151mm X 75mm X 26mm Weight 395g 2 Hardware Description 2 1 Panel layout Screw Terminal TRP C24H 16CHO C Modbus TCP Module s 111MM cee Auto MDIX RJ 45 sessssscee Notice The Module provides two type power inputs optional DC JACK or Screw Terminal input not to two used together 2 2 Block Diagram PWR LED Blinking is ready LINK LED RJ 45 cable connection and data active DO DF LED Each digital status indication DC Jack Power Input DC 10V to 30V Please use the 5 5 2 1mm DC JACK 2 3 Factory Button Hold down the button and then power on until the power light
14. ddress DHCP IP Port Mode Status 101 TRP C24H 00 0E C6 00 00 74 Enable 192 168 1 1 502 Master Idle gt DSM Function Search IPSearch i Device Setup Web Browser Restore Reboot EE DSM Status Idle Poges NRRRRRRRRRRRERRRRRE Upgrade B WEB Server http www trycom com tw TRP C24H Isolated 16 CH O C Modbus TCP WDT inside Mea TRP C24H Setting Network Settings 4 1 Using DSM Utility The DSM utility software performs several functions A Searching for TRP C24H connected to the network B Displaying and changing the configuration C Upgrading the TRP C24H firmware Refer the Firmware upgrade help file D Saving and Loading Configuration from external log File or EEPROM 4 2 Searching TRP C24H Once TRP C24H is connected to the network the DSM software will search it and display it in a window by name IP address Mac Information EQIRYCOM DSM 4 6 ee o x TRP Ethernet Series DSM IPC TRP C37 C37M C24H C26H C28H DSM Setting _ Device Status List Setting Device Name MAC Address IP Status CF TRP C24H 00 0E C6 00 00 74 Enable 192 168 1 1 302 Master Idle r DSM Function IP Search Device Setup Web Browser Restore Reboot st Upgrade DSM Status Idle Poges NRRRRERERRRRERRRRER 4 3 Configuring Server Properties Select the NO item and Double click to open the module configuration after
15. de Output jo Digital Input CH14 _ Safe On Mode Output jo Digital Input CH15 CS Digital Input CH16 jo Save Load Device Name Device server name Maximum 10 chars Model Name TRP C24H MAC Address The TRP C24H MAC address DHCP If DHCP is disabled it allows user setting the IP address Subnet mask Gateway If DHCP is enabled the IP address Subnet mask Gateway address will be dynamically configuration by DHCP server such router When DHCP is enabled but the DHCP server is not available on the network the TRP C24H will timeout then back to factory setting IP 192 168 1 1 Server Listening IP The TRP C24H IP address Server Data listening port TRP C24H port address Client Destination IP When user using the pair mode the client setting need to input module IP and port which one need to connect Client Destination port Client port address Port 16 bit number 1 65535 Netmask The default LAN Netmask is configured for a Class C address This maybe reconfigured by the user Gateway Input the gateway IP address that can be allows users to access the serial server from internet DNS Short for Domain Name System an Internet service that translates domain names into IP addresses Because domain names are alphabetic they re easier to remember The Internet however is really based on IP addresses Every time you use a domain name therefore a DNS service must translate the n
16. digital output readback count value 6 2 ID 05 00 NN DD 00 Write Single Coil Write Single channel output data 6 3 ID OF 00 SS 00 NN 01 XX Write Coils Write multi channel output data 6 4 ID 06 00 SS DD NN 01 XX Write single register Write single channel counter value 6 5 ID 16 00 SS 00 NN 01 Write multiple registers Write multi channel counter value 6 6 Additional Modbus TCP Command List Coulee Ls Function Description Index ID 46 00 00 Read the module s name 6 7 ID 46 04 IP 00 00 00 Setting module new ID 6 8 ID 46 07 00 Read the module s Firmware 6 9 ID 46 OB WS 00 Enable Disable watchdog 6 10 ID 46 0C 00 Read watchdog status 6 11 ID 46 0D 0S 00 Set up LED ON OFF 6 12 6 1 Read Coils Read digital output readback value Command i 01 00 SS 00 NN ae 1Byte Address of setting module 1 247 1 Byte Function Code 00 SS 2 Bytes Start channel number 0xO000 0x000F 00 NN 2 Bytes Output channel number 0x0001 0x0010 ID 1 247 01 Function Code Response ID 01 BC LL HH 5 Bytes BC Byte counter LL HH Digital output read back value ID 1 247 81 Function Code ER 00 Syntax error ER 01 Data Format error ER 02 Start channel error ER 03 I O out of range Example Send command 01 01 00 00 00 10 Read DOO DOF Output read back value Response 01 01 02 21 43 2bye DO7 DO0 21 DOF DO8 43 26 6 2 Read Holding Registers Read the current digital output readback cou
17. end command 01 10 00 00 00 03 06 00 OA 00 14 00 1E Write DO 1 3 Counter Value Response 01 10 00 00 00 03 Command Valid 6 7 Read the module s name ID 46 00 00 Address of setting module 1 247 Function code Read module s name Reserved code ID 46 00 00 Module command Line ID 46 00 00 0C 24 00 OC 24 Module s Name is C24 ID C6 00 ID C6 C 6 Function Code 00 Reserved code EX Send Command 01 46 00 00 Read the TRP C24 s name Response 01 46 00 00 OC 24 00 Module s name is C24 Error Response 01 C6 00 Error code 29 6 8 Setting module new ID ID 46 04 IP 00 00 00 ID Address of setting module 1 247 46 Function Code Setting module ID IP New module s ID 00 00 00 Reserved code ID 46 04 00 00 ID 46 04 00 00 Command valid ID C6 00 ID C6 C 6 Function Code 00 Reserved code EX Send Command 01 46 04 08 00 00 00 Set up the new ID is 03 Response 01 46 04 00 00 New ID is 08 Error Response 01 C6 00 Error code 6 9 Read the module s Firmware ID 46 07 00 ID Address of setting module 1 247 46 Function Code Read module s Firmware Reserved code ID 46 07 Module command Line YY Year MM Month DD Date 00 Reserved code ID 46 07 YY MM DD 00 ID C6 00 ID C6 C 6 Function Code 00 Reserved code
18. flashes Release the button 2 4 Factory parameter values Device Se j x Network Setting Serial Port Modbus Setting Device Name Module Name TRP C24H MAC Address o0 DE C6 00 00 74 NE 255 2552550 PACE Enable He 192 168 1 3 A Server Master Listening IP 192168 11 DNS 168 95 1 1 Data listening port 502 Transmit Timer 10 C Client Slave Heart Beat s UID Range ClentSleve IP Address Pot 77s Disable x fp To fi EEE 2 o Maximun Connection fe z fp To j o 0 0 fi TCP Keep Alive F7 7 fp To F foo 0 0 fi Nee Pawon pe g S f es pS fp Firmware Version 408 fp ae 5 fe ng p Data Packet Type Management Packet Type fp T j po 00 jp M UDP m Auto connect V Broadcast fp To jp oo 0 0 jp after reboot I Multicast V TCP fp To fi foo 00 E Save Load Device Setup Network Setting Serial Port Modbus Setting r Serial Port Setting Digital Output Status E Baud rate 600 Digital Input Status CRE Digital Input CH1 a ae J Digital Input CH2 Cc Parity fiom DigitlinptcH3 0 Digital Input CH4 CE me fi F7 Digital Input CHS CE Flow Control Flow Digital Input CH6 CE Motes Ste Digital Input CH cl Slave ID Digital Input CH8 a Led Display Panel Setting On DigitlInputCHo 0 Digitsl Input CH10 CS Res Si Z DigitalInput Hit Do System Mode Power On Mode Digital Input CH12 oo Trycom Checksum Seting Disable Z Digisi mpntCH13 Eana Power On Mode Output jo Digital Inp
19. ial COMS m A Remote Server IP 192 168 1 1 X Remote Server PORT 4000 a Map mode cient z Nate J OK X Cancel Step7 If Virtual Com setting success the display will appear bellow Step8 Run TRPCOM utility then select virtual com port make a TRP C24H command If in VCOMM s configuration select Boot with windows the virtual com will Auto connection when windows start 24 Basecontig Networkconfig Workconfig MAD Te IF Init VSP when Star IV Clear YSP when Start J Ignore used YSP when exit IV Eanbled Device Scaner Process priority Noma Thread priority Normal x GUI default mode Normal 7 Data refresh interval X Cancel TRP C24H in use the Virtual com mode the default data format is 9600 N 8 1 this mode is not allowed to change Fo TRPCOM Test Utility Setting Termial Scan TCPAP About Terminal Command Input Send Command 1100010 Response 01 01 02 33 71 6D 28 Checksum ot 01 00 00 00 10 3D C6 Command Checksum Description Send the module s command and get real time response If your module s checksum configuation setting is enable the command checksum will show you the send command status 25 Modbus TCP Command List Command List Function Description C24H Description Index ID 01 00 SS 00 NN Read Coils Read digital output readback value 6 1 ID 03 00 SS 00 NN Read Holding Registers Read the current
20. m return Response IID CHK cr Command valid ID CHK cr Command Invalid EX Send Command Back to factory Response 01 22 6 Modbus RTU ASCII Communication Protocol For more modbus RTU ASCII protocol specification please download from http www modbus org website Obtain more modbus TCP instruction test we recommend user can be downloaded from the following Web site Modbus Poll Test utility http Awww modbustools com Modbusscan Test utility http Avww win tech com html modbus1 htm User can use the virtual com program with TRPCOM exe for Modbus RTU test these programs can be found in our directory of the CD Install the Virtual COM Step 1 Insert the TRP Serial CD and find the TRP C24H folder Step 2 Click Vcomm exe icon then install Virtual COM utility The Virtual COM utility support multi language please select which language do you need Step3 Click OK button and select VSP run as Client support Server Device 23 Step5 Run VCOMM exe then click right button select New Virtual COM Virtual Serial VSPM run as Client support Server Device Ver3 16 Manager Config Minimize VSPM About Exit Scan and Append Device irtual COM Edit Virtual COM Delete Virtual COM Minimize SPM Manager Device Config UpdateState Step6 Select Select Serial Port and input TRP C24H IP and port then press OK Ser
21. nt value Command fio 03 00 SS 00 NN a 1Byte Address of setting module 1 247 1 Byte Function Code 00 SS 2 Bytes Start channel number 0xO000 0x000F 00 NN 2 Bytes Output channel number 0x0001 0x0010 ID 1 247 03 Function Code Response ID 03 BC NN NN 5 Bytes BC Byte counter NN NN Digital output read back value ID 1 247 83 Function Code ER 00 Syntax error ER 01 Data Format error ER 02 Start channel error ER 03 I O out of range Example Send command 01 03 00 00 00 03 Read DOO DO3 read back counter value Response 01 03 06 00 12 00 06 03 0A Byes Counter 6 CHO Counter Value 12 DO1 Counter Value 06 DO3 Counter Value 778 6 3 Write Single Coil Write Single channel output data Command i 05 00 SS DD 00 a 1Byte Address of setting module 1 247 1 Byte Function Code 00 SS 2 Bytes Start channel number 0xO000 0x000F Write output data DD 00 Output Disable DE ee 2 pyres DD FF Output Enable ae ae ID 1 247 85 Function Code ER 00 Syntax error ER 01 Data Format error ER 02 Start channel error ER 03 I O out of range Example Send command 01 05 00 06 FF 00 DO6 Output Enable Response 01 05 00 06 FF 00 Command Valid 27 6 4 Write Coils Write multi channel output data ID OF 00 SS 00 NN BC LL HH Ie 1Byte Address of setting module 1 247 00 SS 2 Bytes Start channel number 0xO0000 0x000F 00 NN 2 Bytes Output channel number 0x0001 0x0010 BC 1 Bytes By
22. setting then click Submit will save the configuration to memory Device Setup xi Network Setting Serial Port Modbus Setting Module Name TRP C24H Masami 2552552550 ae EX El ue joze o Server Master Listening IP 192168 11 DNS 168 95 1 1 Data listening port 502 Transmit Timer fio C Client Slave Heart Best UID Range ClientSlave IP Address pot 79s Disable x p To E 192 168 1 2 fs02 Maximun Connection fe z fo to fo pom fl TCP Keep Alive P z pm To or foo 0 0 fi EE OREN fe to fo po CE arn 308 p To e 0 0 0 0 E Data Packet Type Management Packet Type pP To p 00900 FE CE eX FF Broadcast PE To rv 0000 PE after reboot Multicast fo to fo pom p ao Save Load Device Setup x Network Setting Serial Port Modbus Setting p Serial Port Setting Digital Output Status fT Baud rate a600 v Digital Input Status fi Digital Input CH1 jo Data bits Es jes Digital Input CH2 0 Parity None v Digital Input CH3 jo Digital Input CH4 0 Stop bits 1 5 Digital Input CH5 0 Flow Control None v Digital Input CH6 jo Digital Input CH D Modbus Setting pean Slave ID Digital Input CH8 jo i 7 Digital Input CH9 jo Led Display Panel Setting On Polling Setti Digital Input CH10 jo 0 e Hi ied igh Digital Input Hit f System Mode Power On Mode Digital Input CH12 co Trycom Checksum Setting Disable Digital Input CH13 a Power On Mo
23. t computers smart phones will be available The TRP C24H built in watchdog Hardware ensure the normal operation of the module and a built in voltage monitoring to ensure that the boot excellent and advanced hardware for harsh environment The TRP C24H can TRP C26H 16 remote control directly do not need to run the software and equipment When TRP C24H and TRP C26H are paired they can support 16 channels remote control does not require any drivers and software support The TRP C24H is also offers the maximum connection 16 host client to link the network server that is easy to operate in Modscan32 Modbus Poll CAS Modbus Scanner and SCADA application uses TCP mode and Virtual COM mode 1 1Features Wide input range DC power supply Automatically determine 3 TRP ASCII and Modbus RTU ASCII communication protocol 16 TCP Port can be open at the same time Heart Beat function ensures a reliable communicating connection Support Virtual COM mode IO status can be set in the boot WEB PAGE can be directly output and read IO status Easily update the firmware using the Internet Back to factory configuration by external touch Button Auto reconnection when power or Ethernet fail Digital output signal with 3750Vrms isolation protection Built In watchdog function prevents system boot fail LED for each I O channels working status Support Auto MDIX twisted pair crossover detection and Auto Correction Power Link 16 CH DO LED indi
24. te counter Write output data LL 00 FF LL HH 2 Bytes HH 00 FF Lu oe ID 1 247 8F Function Code ER 00 Syntax error ID 8F ER 3 Bytes ER 01 Data Format error ER 02 Start channel error ER 03 I O out of range Send command 01 OF 00 00 00 10 02 12 34 Output DO Data DOO DO7 21 DO8 DOF 43 Byte Counter 02 Response 01 OF 00 00 00 10 Command Valid Example 6 5 Write single register Write single channel counter value ID 06 00 SS DD DD Address of setting module 1 247 Function Code Start channel number 0x0000 0x000F Write Counter Vaile DDDD 0x0000 0xFFFF ID 06 00 SS DD 00 Command Line ID 86 Function Code ER 00 Syntax error ID 86 ER CRC ER 01 Data Format error ER 02 Start channel error ER 03 I O out of range Example Send command 01 06 00 09 1A 37 Write DO9 Counter Value 1A37 Response 01 06 00 09 1A 37 Command Valid 28 6 6 Write multiple registers Write multi channel counter value ID 10 00 SS 00 CN BC DD DD ID 1Byte Address of setting module 1 247 1Byte 10 Function Code 2 Bytes Start channel number 0x0000 0x000F 2 Bytes Counter Number 0x0001 0x0010 1 Byte Byte Counter 2 32 Bytes Counter Vaile DDDD 0000 FFFF ID 10 00 SS 00 CN 6 Bytes Command Line ID 90 Function Code ER 00 Syntax error ID 90 ER ER 01 Data Format error ER 02 Start channel error ER 03 I O out of range S
25. ter Listening IP 192 168 1 1 DNS 168 95 1 1 Web Browser DRE HAN id Data listening port Eu Transmit Timer ClientSlave Heart Beat Disable 7 ath Restore D i Han Port 0 To Bz 192 168 1 2 5022 Reboot 0 To f0 0006 p TCP Keep Alive Fr gt a EH To p pom TS New Password Fe CN 5 p poo p Fimware Version 416 FE T p pov CT Data Packet Type Es Es ee Be EE EN Management Packet Type 0 To fo po fp UDP i r Auto connect IV Broadcast 0 To p 500 fp after reboot I Multicast Iv TCP 0 To p paoa p Device Setup Network Setting Serial Port Modbus Setting Serial Port Setting Digital Output Status Power On Mode Output fi Digital Input CH14 Safe On Mode Output fi Digital Input CH15 Digital Input CH16 Baud rate osoo v Digital Input Status ff00 Digital Input CH1 En Data bits RE IE Digital Input CH2 RTE Parity None Digital Input CH3 fp Digital Input CH4 RTE Stop bits ner Digital Input CH5 fp Flow Control None Digital Input CH6 E LES Digital Input CH7 F Modbus Setting aa se Slave ID cee pen Digital Input CH9 F TN LED Display Panel Setting Of PES TE Digital Input CH10 Doo 0 e Hi eh i Zl pista taper cH a een Mode Pair Mode LP Digitel Input CH12 EE Trycom Checksum Setting Disable Digital Input CH13 T mme fp rec Save Load 33 TRP C26H parameter setting FATRYCOM DSM 47 TRP Ethernet Series
26. to the hard disk and then directly execute TRPCOM exe TRPCOM utility can automatically detect the model it will list the corresponding function key It helps developers to understand and control the digital state Fe TRPCOM 2013 Test Utility Version 1020928 mio E3 P f 92 168 0 109 Port s02 Send the ASCI command Response 1001TRP C24H sot M Auto F a0 Send Command r TRP C26H 28H Digital Input Counter Value DO D1 D2 D3 D4 DS D6 D7 oooga LE 6 6 Hoo0o 6 6 6 Oooo CUUU GOUT Oooo DS D9 DA DB DC DD DE DF oooga Oooo Hoo00 6 6 6 ooo0 CUUU Oooo GOUU DODI Status mouu Command Response _ Auto Read m TRP C24H Digital Output Control DO D1 D2 D3 D4 DS D6 D7 D D9 DA DE DC DD DE DF TRP C2KH Common commands Back to Factory Reset Counter Clear D O Value Setting Power On Description The TCP IP Function Please enter the test device s IP and Port then press the Link button The program will automatically determine the type and lists function keys 1 Test device serial Server loop back wiring 2 Test TRP C24H C26H C26H Ethernet O 12 5 TRP ASCII Communication Protocol TRP C24H supports three modes of communication Protocol TRP ASCII Modbus RTU Modbus ASCII TRP ASCII Command Protocol Description Command Format Leading Code ID Address Command CHK cr at Leading
27. ut CH14 E Safe On Mode Output CSS Digital Input CH15 oe Digital Input CHIE 0 we J a 2 5 Screw Terminal Pin assignment Description O8 DO9 O8 DOs O8 DO7 e O8 si O8 DO5 d Og O8 DO3 e CYB DO2 e 2 6 Block Diagram 2 7 Pin Description Mie ee Ba E PE a ee CE Ba Es Digital output Channel 9 Digital output Channel 0 EXT PWR The isolated side power input MAX 30V EXT GND The isolated side ground DO8 Digital output Channel 8 DC 10 30V Input DC 10 30V DO7 Digital output Channel 7 3 Install TRP C24H Hardware STEP1 Connect power source with TRP C24H the PWR LED will blinking STEP2 Connect TRP C24H with netwotk by RJ45 cable If the cable is properly connected the LINK LED will light up The TRP C24H Support Auto MDIX A straight through or crossover RJ45 cable can be used to make a connection directly to the HUB Router PC LAN port STEP3 Connect TRP C24H screw terminal wiring such as 2 5 picture description 4 How to configure TRP C24H Please note that the computer s IP segment adjusted with TRP C24H same section modify the parameter values in order to effectively store For example Computer IP is 192 168 1 xx TRP C24H 192 168 1 1 There are 2 ways can change the module parameter values A DSM Software EQ IRYCOM DSM 4 6 aa Jx IPC TRP C37 C37M C24H C26H C28H p DSM Setting Device Status List Setting NO Device Name MAC A