Home
CUSTO LAN RS User Manual
Contents
1. Pin Signal Sa 1 GND i 2 12Vdc 2 1 External power unit 12 Vdc Check that the power unit can supply all the connected devices DC 12V OUT NJO 25 dh EGA gogo 525 12345678 Custo LAN RS Custo LAN RS Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 4 25 CUST LAN RS Be careful do not connect 2 external power supplies to the IN and OUT DC12V connectors at the same time 2 2 Power supply It is possible to supply directly the Custo LAN RS by the RJ45 connector if the network meets the requirements of the 802 3af standard Thus a 12Vdc tension is available on the IN and OUT DC12V connectors As a results it is possible to supply a second device by these connectors But the power used by this device cannot be above 500 mA If the network do not meet the 802 3af standard requirements It is possible to use PoE injector reference SP390 to supply the card via the RJ45 connector no PoE Hub
2. Custo LAN RS RS485 connection 1 dg rga pga Ga aga A ILI LLILI Custo LAN RS RS485 connection Tel RS485 connection VIMATY 70S 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com CUST LAN RS Due to the way that the custo LAN RS functions connecting 2 Custo LAN RS card at the same time to the same Ethernet network and to the same RS485 bus is to be avoided Wrong installation HUB PC TACUN TACTUM Ethernet bus pum COCH OJOJ UJETI
3. Address 1 to 8 Dipswitch ON 1 Dipswitch 1 OFF All the others ON 12345678 2 Dipswitch 2 OFF All the others V REFER 12345678 ON 3 Dipswitch 1 and 2 OFF All the others ON eee 12345678 ON 253 Dipswitch 2 ON All the others OFF Ay 12345678 ON 254 Dipswitch 1 ON All the others OFF E 12345678 ON 255 the dipswitchs OFF 12345678 2 4 Ethernet network connection Straight wiring between Custo LAN and HUB Side A Side B 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 Note Wires 1 and 2 lt 1 twisted pair Wires 3 and 6 lt 1 twisted pair Wires 4 and 5 lt 1 twisted pair Wires 7 et 8 lt 1 twisted pair Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com Cross wiring between Custo LAN and PC Side A Side B 1 3 A WU CO J NU A L2 O 7 25 CUST LAN RS female RJ45 pinout Pin Signal TX Tx a Rx In 48V PoE 48V PoE Rx 87654321 In 48V PoE In 48V PoE WU NE The wire used must be a C
4. L IN Custo LAN RS OUT kaj mm SEDELA IN Custo LAN RS ON A OUL 12345678 Custo LAN RL J VITY automation systems XMONOPRO dim Media Bus Control X MINIMONO 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com CUST LAN RS To communicate the RS485 bus each Custo LAN RS must have an address This address is defined by the 1 to 8 dipswichs located near the RJ45 connector and nominated ADDRESS by the screen printing This address enables to identify the different Custo LAN card that are present on the RS485 bus Address configuration
5. Custo LAN RS Custo LAN RS RS485 bus RS485 bus DUS VIMATY 35B 70S XMONOPRO The following installation is to be preferred HUB EI oh LN PC TACUN 7 TACTUM CE Ethernet bus SEO CELE Custo LAN RS Custo LAN RS RS485 bus RS485 bus VIMATY 35B RS485 bus 27 705 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 10 25 CUST LAN RS 2 7 Assembly on DIN rail It is possible to install the Custo LAN RS on a DIN rail with the optional CUSTO DIN You only have to clamp this rail DIN kit under the box with two M3 x 6mm screws Custo LAN RS CUSTO DIN 3 OPERATION When powered up the Custo LAN RS sends a reset message on the RS485 bus and the identification UDP broadcast on the Ethernet The ON led turns on showing the right use of the card If the Custo LAN RS is connected to the Ethernet network the green led of the RJ45 connector turns on The yellow led of the RJ45 connector turns on when an Ethernet frame is transmitted or received Before being able to send commands on the 2 serial ports it is necessary to initialize them You have to define the operating mode RS232 RS422 RS485 the communication speed the parity the number of data bits per character the number of stop bit and the material control of the stream for
6. 2 3 RS485 Connection MC1 5 3 G 3 81connector pinout PoE injector Ref SP390 AC input Data VDC Power data 12345678 STRE TT Signal 1 Tx Rx 2 Tx Rx 3 GND 3 2 1 Custo LAN RS You can connect the RS485 bus either on the RS485 IN or on the RS485 OUT The second connector is only used to make the cards chaining easier The 35B 35S 35 EIB 70S 70 EIB VIMATY screens the 20S and 20 EIB PADMATY keyboard must be connected to the Custo LAN RS by this bus The mediabus the XMONOPRO the MULTICUSTOM and the MINIMONO can be connected to this bus Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 5 25 CUST LAN RS Tel VITY touch screen and keyboard VIMATY 70S VIMATY 35B PADMATY 20S RS485 BUS ON ass ee Ti
7. 18 6 05 Update NITE TOLLIT III 20 Ser T ICE ERO eiui OX Rn RO aa Rire OR RN ene ani 22 Read carefully this manual before installing the Custo LAN RS The manufacturer won t be responsible for any damages or incidents even caused by a correct use of his products The data and the characteristics of the product can be modified without any previous report Tel 433 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 3 25 CUST LAN RS 1 PRESENTATION The Custo LAN RS enable to manage 2 serial ports by RS 485 or by Ethernet network Each port can be configured in RS232 in RS422 or in RS485 It can also be used as a Mediabus Ethernet gateway The device can be supplied either by an external power supply or directly by the Ethernet network if it corresponds to the 802 3af standard 2 INSTALLATION 2 1 External power supply The external power unit must supply 150 mA under 12Vdc You can connect the power supply either on the IN connector or on DC12V OUT It is possible to supply a second device via the second connector Check that the power supply is able to provide enough power for both devices The connector used for the external power supply is a Phoenix Contact connector reference MC1 5 2 ST 3 81 Connector pinout MC1 5 2 G 3 81
8. ASCII E character that is 0x45 hexad cimal en case of reset or in character reception on the serial ports ASCII D character that is 0x44 hexad cimal in case of identification reguest in character emission towards the serial ports Number of data 1 character egual the number of data present in the segment Datas 1 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 12 25 CUST LAN RS Data It exists 5 possible messages for a Custo LAN RS card 2 don t have any data one message has 4 data and the segment donn es of the other 2 depends on the length of the message received or sent on the serial port 1 Reset Message message type number of data 1 no data 2 identification request message type TD number of data 1 no data 3 Configuration of the serial port message type SC number of data 5 4 bytes of data Data 1 Data 2 Data 3 Data 4 Data 1 N of the concerned port 1 or 2 Data 2 Data2 1 2 3 4 5 6 7 8 9 10 Baudrate 300 600 1200 2400 4800 9600 19200 38400 57600 115200 only available on port 2 Data 3 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 RX RS422 Parity parity Number of RTS CE Mode Type character per bits 00 5 bits 0 no O lt no 0 O yes 0 O pair 01 6 bits 1 yes 1 yes 1 lt no 1 lt odd 10 lt 7 bit
9. The update starts ta Custo LAN Firmware Upgrade m CustolAN Upgrade Copyright 2005 VityTechnology Data transfert IP Address 32168033 Update UDP Port max 65535 Ju When the update is finished the following window appears IP Address 1 Update UDP Port max 65535 Juit Press on to finish the update The Custo LAN RS automatically resets when the datas transfer is finished in order to update its OS NB IF THE CUSTO LAN RS IS CONNECTED TO THE LOCAL NETWORK TO WHICH THE PC OPERATING THE UPDATE BELONGS IT IS IMPERATIVE THAT THE ETHERNET ADDRESS OF THE CUSTO LAN RS CORRESPONDS TO A VALID ADDRESS OF THIS NETWORK Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 22 25 CUST LAN RS 7 TECHNICAL SPECIFICATIONS Ethernet Interface 10 T Base Wire CAT5 Protocol UDP Port 12000 by default Connector RJ45 Serial Interface RS485 Speed 115200 Communication parameters 8 bits of data per character 1 stop bit no parity RS485 connector MC1 5 3 G 3 81 manufacturer Phoenix Contact Consumption 50 mA max 12Vdc External power supply connector MC1 5 2 G 3 81 manufacturer Phoenix Contact Protection by polyswitch PoE power supply 802 standard Number of serial ports 2 available mode RS232 RS422 RS485 speed port 1 300 600 1200 2400 4800 9600 19200 38400 57600 baud s
10. 0x72 0x73 0x69 Ox6F Ox6E Ox3A 0x31 Ox2E 0 ma 1 0x30 Ox2E 0x30 The number of the version is encoded on 3 ASCII character separated by points Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 18 25 CUST LAN RS 5 NETWORK PARAMETERS CONFIGURATION Execute the IdentCusto LAN program ta IdentCustoLAN IdentCusto LAN Copyright 2005 Vity Technology Address IP Address MAC Address UDP Port Name Version 192 168 0 33 CUSTOLANEBL 100 Refresh List Configure IP Settings The software scans all the Custo LAN cards present on the local network even if their address do not belong to this network Select the Custo LAN of which you want to change the Ethernet parameters Press on Configure IP Settings or double click on the line that displays the parameters of the Custo LAN You can change the IP address the UDP port the gateway and the subnet mask Enter the new Ethernet parameters and validate by pressing on UPDATE ta IdentCustoLAN CUSTOLANRL adresse 1 IP Address New IP address E 92 168 0 33 New UDP port Gateway New Gateway chnology 192 168 0 1 1 0 0 Mask New mask 255 255 255 0 Refresh List Configure Settings Close Tel 433 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 19 25 CUST LAN RS When
11. It exists 3 main commands Configuration of the serial port sending of a command on a serial port and reception of a message on a serial port Configuration of the serial port V T Y target ENO Sender ENQ S Nb Datai Data2 Data3 Data4 0x56 0x49 0x54 0x59 0x14 0x14 Ox53 0x43 0x05 0x04 Checksum 0x04 Sending a command on a serial port v T T Y target ENO Sender bei D Nb Data 1 Data 2 Data n 0x56 0x49 0x54 0x59 0x14 0x14 0x53 0x44 0x04 Checksum 0x04 Reception of a message on a serial port T T Y target ENQ Sender ENO 5 E Nb Data 1 Data 2 Data m 0x56 0x49 0x54 0x59 0x14 0x14 0 53 Ox45 0x43 0x04 Checksum 0x04 see the RS485 protocol Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 15 25 CUST LAN RS The acknoledgment of these messages sent in broadcast depends of the validity of the checksum If the checksum is correct the frame contains the acknoledgement the message sent iji T ny ENO ACK ENQ EOT target ENO Sender 0x56 0x49 0x54 0x59 0x14 0x0
12. 0x06 0x15 Reset of a Custo LAN RS card address 1 0 0 0 14 0 01 0 14 0 54 0 45 0 01 0 04 0 9 OxFO is the target by default always used for reset Identification request of the Custo LAN RS card address 7 pby a OxFitransmitter command sent 0x07 0x14 0xF1 0x14 0x54 0x44 0x01 0x04 0x9D Valid acknowledgement of the card OxF1 0x14 0x07 0x14 0x06 0x15 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 14 25 CUST LAN RS 4 2 Ethernet protocol Speed 10BaseT UDP Protocol uses the 12000 port in broadcast receiving uses the 12000 port in broadcast diffusion Uses a customizable port for commands receiving 4 2 1 Commands RS format These messages have the same format as the RS485 messages to which a header composed of a chain of 4 characters VITY is added As the RS 485 commands these UDP messages enable to configure the the serial ports to send and to receive RS messages These commands use the parametrizable UDP port and can be sent to the Custo LAN RS card in broadcast or thanks to its IP address If the RS 485 address or the ENQ character of the message do not correspond to those of the Custo LAN RS the message is directed to another device present on the RS 485 Bus The message is then sent to this bus Message structure Header VITY RS485 message RS485 header message type nb data data checksum
13. EE A TEES 4 2035 R5485 ONE NEIN vnd wear ad CE De eS TR VER AER RE RV GV OR S RV E 4 2 4 Ethernet network connection sees nenne hehehe heh ra nnn nnn nnn 6 di POE O OP 7 2 5 1 Female FODOBEDAE ve A vea a Ur aX v a wr 7 PASSI Wu RAN E EIBCSI Eo EIE TII LT LOUER 7 2 6 RS485 Ethernet connectiOn anni ina nnn rra rare nnn 8 2 7 Assembly on DIN ei NET EE OM 10 ARNE tlO ine ee peda ANE U A PAM CUN NU a a ee EN RAN 10 LEE uibus ss RENTEN ee ee a ee ee a a ee ea ae 11 T T D Tm 11 2 1 A DOO NE NO NANA ine ne ae Ed n dra datis tuque 11 4 1 2 Commands format au e eere tr Eros eR ux Eure be Svr DE ke YEUX 11 4 2 DIURODOL a at 14 4 2 1 Commands RS fOrmat cccccccccecccccceucccunceeuueeaneeuneeuneeenteneneeuuteantenutenuutnuunnanenes 14 4 2 2 Identification COMNand sie ina dek rake iac i deia ka ne dig dika 15 et da ee aT 16 l ZA EO IRIS UTER 17 5 Network parameters
14. 0x74 0x65 Ox3F card acknowledges with the following frame T Y ENQ ACK ENQ EOT 0x56 0x49 0x54 0x59 0x14 0x06 0x14 0x04 Then the card sends the message that involves its name T T lo E ic r t le 1 1 0x56 0x49 0 54 0x59 Ox6E Ox6F Ox6D Ox5F 0x63 0x61 0x72 0x74 0x65 Ox3A C U O 1 N R 0x43 0x55 0x53 0x54 Ox4F Ox4C 0x41 Ox4E 0x52 0x53 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 17 25 CUST LAN RS 4 2 4 Version request This command enables to obtain the OS operating in the Custo LAN card Le PC sends the following UDP command to the IP address of the target with as target port the local port of the targeted card T T el 1 o 0x69 Ox6F Ox6E Ox3F 0x56 0x49 0x54 0x59 0x76 0x65 0x72 0x73 The card acknowledges with the following frame EOT 0x56 0x49 0x54 0x59 0x14 0x06 0x14 0x04 Then the card sends the message that involves the operating software version T 7 y le ls i lo an LA 0x56 0x49 0x54 0x59 0x76 0x65
15. 53 0x54 Ox4F Ox4C 0x41 4 0x52 0x53 Name of the card in this example CUSTOLANRS depends of the card 0 2 0 2 0 2 version number depends of the MAC address different for each card software installed in the microcontroller Tel 433 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 16 25 CUST LAN RS ta 37 39 y n 192 168 0 1 Ox2C 0x25 0x27 Ox2C Ox2C OxCO OxA8 0x00 0x01 IP address different UDP local RS485 Gateway different for each card port address for each LAN n 255 255255 0 Ox2C OxFF OxFF OxFF 0x00 Sub network mask different for each LAN This message is sent back to the IP address of the sender of the identification command with as UDP target port the source port of the sender The message is also sent to the Ethernet network in broadcast with as target port 12000 after a Custo LAN RS reset 4 2 3 Name request This command enables to obtain the name of a Custo LAN card The PC sends the following UDP command to the IP address of the target with as recipient port the local port of the targeted card T I lo 5 le a r t le 0x56 0x49 0x54 0x59 Ox6E Ox6F Ox6D OxBF 0x63 Ox61 0x72
16. 6 0x14 0x04 0x14 If not the frame is dra T ENO NACK ENO EOT 0x56 0x49 0x54 0x59 0x14 Ox15 0 14 0 04 Another reply can be returned if the Custo LAN RS is already processing a RS485 or UDP T Ts Y B 8 Y 0x56 0x49 0x54 0x59 0x42 0x55 0x53 0x59 message The received message won t be processed In that case the reply is 4 2 2 Identification command This command enables to identify the Custo LAN cards present on the local network This UDP command uses the target port 12000 It is sent in Broadcast diffusion in order to be able to be free of local network parameters Format of this command T I S ic al u is t o 0x56 0x49 0x54 0x59 0x53 0x63 Ox61 Ox6E 0x20 0x43 0x75 0x73 0x74 Ox6F L N 12 Ox4C Ox41 Ox4E Ox3F When receiving this broadcast request all the cards present on the local network return the following message T T S te a le t lo 0x56 0x49 0x54 0x59 0x53 0x63 Ox61 Ox6E 0x20 0x43 0x75 0x73 0x74 Ox6F tle N 1 1 je U IE N R 4 0x41 Ox4E Ox3A 0x43 0x55 0x
17. AT5 4 twisted pair wire To connect a Custo LAN RS to a Hub It is necessary to use a straight wire To connect a Custo LAN RS directly to a PC a cross wire is needed see the previous graphs 2 5 Serial Ports 2 5 1 Female subD9 connector Base Signal 1 RX RS232 TX RS232 5 1 TX Rx 9 6 RTS RS232 CTS RS232 Rx A UN 2 5 2 Communication parameters Communication speed Baudrate 300 600 1200 2400 4800 9600 19200 38400 57600 115200 Poti V vV v v v v wv v v Pot2 V v v v v v v v Parity none even odd Number of bits per character 5 6 7 8 Number of stop bit 1 1 5 2 Possible configuration RS232 RS422 RS485 Hardware handshake in RS232 mode by RTS and CTS In the RS485 mode It is necessary to connect the pin 1 to the pin 6 and the 4 to the 9 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 8 25 CUST LAN RS 2 6 RS485 Ethernet connection Le Custo LAN RS can be used as a Ethernet Mediabus gateway It transfers the messages that are no directed to itself to the RS485 bus or to Ethernet PC TACUN m TACTUM Ethernet connection ON
18. ITY www vity com TECHNOLOGY CUSTO LAN R User Manual MEDIA BUS C made in france CONTROL CUST LAN RS THANK YOU amp CONGRATULATIONS Thank you for purchasing the CUSTO LAN RS controller of VITY Media Bus Control automation system CUSTO LAN RL is a small controller that enables to drive 2 rs 232 by Vimaty touch panels or by TCP IP This manual is made to assist you to install the CUSTO LAN RS The information in this manual is copyright protected No part of this manual may be copied or reproduced in any form without prior written consent of VITY Technology Headquarters France VITY Technology is not responsible for operational technical or editorial errors omissions made in this manual All the information in this manual may be subject to change without prior notice CUSTO LAN RS and Media Bus Control are register trademarks of VITY Technology All other brand or product names are trademarks of their respective companies or organizations TECHNOLOGY 180 rue Pierre Landais 56850 Caudan France WWW VITY COM CE REVISION NUMBER OF THIS MANUAL CUSTOLANRS UM 220807 0003 Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 2 25 CUST LAN RS INDEX BS i i TETTE ek aa Na ee ek 3 DENA IN acai a ae ee e ea a ee ek a ke a aaa e 3 2Z DI DATE NM sup vats nace ee Us 3 2 2 POE A aj
19. claims and excludes all other warranties whether express implied or statutory 4 Buyer s Exclusive Remedies for Any Nonconformity If a VITY product fails to conform to the warranties in Section 1 Buyer must notify VITY within a reasonable time and in no event more than thirty 30 days after the discovery of the nonconformity and VITY will repair any nonconforming products or components 5 Application of the warranty During the period of warranty VITY Technology will repair the defective units free The defective products must be sent to your expenses to the VITY Technology s offices Caudan The repaired units will be turned over to our expenses with the recipient Apart from the period of warranty VITY Technology will repair the defective units in its offices at Caudan and the cost of repair will be the responsibility of the customer In the case of the defected product was bought to a Vity subsidiary or a Vity distributor you have to return it directly to them 6 Exclusion of Consequential and Incidental Damages Vity shall be not liable under any circumstances for consequential or incidental damages including but not limited to labour costs or loss of profits arising in connection with the use of or the inability to use Vity products 7 Transport Damage VITY will not be responsible for items damaged during shipment to or from VITY The shipping carrier is responsible for items damaged during shipment 8 No Modifications Thi
20. luded The reply of a CustoLAN card depends on the validity of the checksum of the received command This reply is composed of a header of 4 characters similar to the header previously defined and 2 extra characters If both the command and the checksum are valid the following frame is returned header 0x06 hexadecimal 0x15 hexadecimal If not the frame is header 0x15 hexadecimal 0x15 hexadecimal Examples sending of a characters chain test to the port 1 of the Custo LAN RS card address 5 transmitter address OxF2 command sent Target ENO Sender ENO psi D Nb Port t e S 0 04 Checksu m 0x05 0x14 OxF2 0x14 0x53 0x44 0x06 0x01 0x74 0x65 0x73 0x74 0x04 0x62 Valid acknowledgement of the card Target ENQ Sender ENQ ACK NACK OxF2 Ox14 0x05 0x14 0x06 0x15 Configuration of the port 2 of the Custo LAN RS card address8 transmitter address OxF1 baudrate 19200 pair parity 8 data bit per character 1 stop bit RS232 mode command sent Target ENO Sender ENO S Nb Datal Data2 Data3 Data4 0x04 Checksum 0x08 0x14 OxF1 Ox14 0x53 0x43 0x05 0x02 0x07 0x03 0x07 0x04 0xB2 Valid acknowledgement of the card Target ENQ Sender ENQ ACK NACK OxF1 0x14 0x08 0x14
21. ology Headguarters France and its subsidiaries VITY china VITY USA warrant their products any defects in materials and workmanship for a period of 2 years from the date of the invoice This warranty concerns products manufactured by VITY Technology A return material authorization RMA must be obtained from VITY before products are returned for service This authorization can be obtain on the website of vity www vity com and have to be returned by fax to VITY 33 297 89 20 10 In the case of product is distributed by Vity Technology the applicable warranty is the warranty of the manufacturer and can be less or more than 2 years This warranty will be specified on the invoice Warranty of CUSTO LAN RS 2 years 2 What This Warranty Does Not Cover This warranty does not apply to a any VITY product that has been modified altered or repaired by an unauthorized agent or improperly transported stored installed used or maintained b damage caused by acts of nature including flood erosion or earthguake c damage caused by a sustained low or high voltage situation or by a low or high voltage disturbance including brownouts sags spikes or power outages or d damage caused by war vandalism theft depletion or obsolescence 3 Disclaimer of Other Warranties The warranties contained in Section 1 are the exclusive warranties given by VITY and supersede any prior contrary or additional representations whether oral or written VITY dis
22. peed port 2 300 600 1200 2400 4800 9600 19200 38400 57600 115200 baud Parity pair odd none Number of bit per character 5 6 7 8 Number of stop bit 1 1 5 2 RS232 mode Material control of data stream by RTS and CTS Connector Female subD9 Dimensions 126 x 85 x 31 mm Weight 420g Options PoE Injector Reference SP390 quium jer e hal tet EE uud Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 23 25 CUST LAN RS G BRANDS COMPATIBILITY MEDIA BUS CONTROL automation systems is compatible to drive many brands of the AV manufacturers lights manufacturers and EIB manufacturers You will find here a list with main brands but Media Bus Control can control more systems 3M ABB Adtec Akg AllenHeath Analogway Ask Autopatch Barco Behringer Biamp Canon Clipsal CommTec DIS Epson Extron Faroudja Fostex Hager Imerge Jung JVC Kenwwod Knox Kodak Kramer Legrand Lexicon Lightec Lite Touch Lutron Meridian Merten Mitsubishi Nec Niko Onkyo Panasonic Phillips Pioneer Pixelmagics Proxima RGB Spectrum Samsung Sennheiser Siemens Sharp Sony Tasca Theben Vigatec Vity Xantech Yamaha Zumtobel and more Tel 433 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 24 25 CUST LAN RS O WARRANTY 1 VITY Warranty VITY Techn
23. s 11 8 bits Data 4 Bit 7 Bit6 Bit5 Bit 4 Bit 3 Bit 2 Bit 1 Bit O TX CTS deae a control valid Number of stop bits RTS TX CE O RS422 0 no 0 a 86485 9 lames dreves 1000 io y 1111 2 To activate the material control of the stream RTS CTS in the RS232 mode the bit must be at 1 To be in the RS422 mode the bit 6 of data 3 must be at 1 and the bit 7 of data 4 must be at 0 To be in the RS485 mode the bit 6 of data 3 and the bit 7 of data 4 must at 1 4 Sending a command to a serial port message Type SD number of data number of useful data 2 data Data 1 Data 2 Data Data 1 of the serial port concerned de 1 a 2 Data 2 1rst character to emit on the serial port Data n last character to emit on the serial port 5 Character reception by a serial port message type SE number of data lt number of useful data 2 data Data 1 Data 2 Data m Data 1 N of the serial port concerned de 1 2 Data 2 1rst character received by the serial port Data m Last character received by the serial port Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com CUST LAN RS Checksum 2 characters ler character 0x04 hexadecimal 274 character sum of the characters from the first message type character to the first checksum character 0x04 inc
24. s warranty may not be modified except in writing by an authorized VITY officer 9 Other Notice VITY reserves the right to modify or discontinue designs specifications warranties prices and policies without prior notice Tel 33 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 25 25
25. the RS232 mode These parameters depend on the devices connected to the serial ports By default the 2 serial ports are initialized in the RS232 mode at 9600 baud no parity 8 data bits per character 1 stop bit The initialization parameters are not stored After each reset you have to reinitialize the serial ports The number of characters emitted is limited to 32 bytes by message In reception if the message contains more than 32 bytes it is segmented 100 ms later if no new characters have been received the data already received are sent on the RS485 bus and Ethernet The Custo LAN RS can either receive orders from the RS485 Bus and from the Ethernet network The characters received on the serial ports are also sent on the RS485 bus and the Ethernet network A button closed to the relay connectors enables to reset the device All the RS485 valid commands correct checksum circulating on the bus are sent on the Ethernet network in broadcast The RS485 commands are encapsulated in an UDP frame recipient port of 12000 and a header message composed of the following 4 ASCII character VITY All the received UDP commands whose format corresponds to the defined protocol see the Ethernet protocol are sent on the RS485 bus It concerns both the commands that are not directed to the Custo LAN RS but directed to the cards and the devices connected on the RS485 It also concerns the commands that send a message to the serial ports of the C
26. the update is finished press on OK and close the application Address 19216602 Version 2 1 0 0 255 255 0 0 Refresh List Configure Settings Close Tel 433 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 20 25 CUST LAN RS 6 OS uPDATE Execute the MajCustoLAN program ta Custo LAN Firmware Upgrade m m Custot AN Upgrade Copyright 2005 VityTechnology IP Address 1 92 168 0 34 e Port max 65535 0022 Quit Enter the address and the UDP port of the target Then press Update Select the update file The file must have a cln extension Regarder dans t e E3 Nom 4 Date de modifica custolanrl cln 21Ko Fichier CLN 29 11 2005 12 1 om Nom du fichier Fichiers de type Fichier CustoLAM Annuler Confirm the update According to the number of the update version and of the current version present in the Custo LAN RS the message can be different Custo LAN Firmware Upgrade mE Checking version Current CustoLAN version 1 0 0 File version 1 0 0 CustoLAN version is the same of the version you want to upoload Continue Oui UDP Port max 65535 uit Tel 433 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com CUST LAN RS
27. usto LAN RS This transfer is done to inform the different devices connected on the RS485 Bus Tel 433 2 97 89 20 02 Fax 33 2 97 89 20 10 Mail sales vity com Web www vity com 11 25 CUST LAN RS 4 PROTOCOL 4 1 RS485 protocol 4 1 1 Communication parameters Communication speed 115200 baud Number of bits per character 8 Parity none Number of stop bit 1 Pinouts It is indicated on the cover of the box by the screen printing and in the paragraph RS485 Connection Connectors that are to be used manufacturer Phoenix Contact reference MC1 5 3 ST 3 81 NB We can either use the or OUT connector to control the Custo LAN RS card 4 1 2 Commands format The commands respect the format defined by the Xmonopro with a 0x14 ENO Message pattern header message type Number of data Data Checksum header 4 character irst character target address 2nd character ENO 3rd character transmitter address 4th character ENO With ENO lt 0x14 hexadecimal target address between 1 and 255 and transmitter address 1 and 255 message type 2 characters 17 character 2 possibilities ASCII S character that is 0x53 hexadecimal to define a Custo LAN RS card ASCII T character that is 0x54 hexadecimal in case of reset or identification 274 character 3 possibilities ASCII C character that is 0x43 hexadecimal to configure the serial ports
Download Pdf Manuals