Home
Element™ Meter - Operation Manual
Contents
1. Contents Intended use of Element Blood Glucose Test Meter Learning the System Intended use of Element Auto coding Blood Glucose Test Meter Element Auto coding Blood Glucose Monitoring System Kit Contents Element Auto coding Blood Glucose Test Meter Element Auto coding Blood Glucose Test Meter Display Element Auto coding Blood Glucose Test Strip Information 2 Before Testing Setting your blood glucose test meter Auto Coding Function Performing a Glucose control solution test 3 Testing Your Blood Glucose Testing Your Blood Preparation Collecting a Drop of Blood Testing Procedure Testing Your Blood Case of Setting user Option Test Strip Ejector Funtion 4 Reviewing Your Results 5 Alternate Site Testing 6 Performing a Blood Test using and Alternate Site 7 Element Auto coding Blood Glucose Test Meter Software 8 Taking Care of Your Blood Glucose Test Meter Cleaning Your Blood Glucose Test Meter and Maintenance Replacing the Batteries Dispose of meter and batteries 9 Troubleshooting 10 Specifications 11 Conversion table mmol L lt gt mg dL 12 Symbol reference 13 Warranty 6 www infopia21 com 10 11 12 13 14 15 16 17 18 19 21 22 24 20 26 27 28 29 30 31 32 33 33 34 37 38 39 40 41 The Element Auto coding Blood Glucose Monitoring System is intended for in vitro diagnostic use only Element Auto coding Blood Glucose Monitoring System is for self tes
2. test meter to a computer You can download the software from our web site http www infopia21 com You can purchase the computer communication cable separately from a local 1 Hold the clear cap down against the top of representative Lance the test site with the lancing device your test site Press the release button Do not lift up K seconds 2 Continue to hold the lancing device and J 3 While holding the lancing device on your mP test site look through the clear cap until a gradually increase pressure for several drop of blood appears approximate e size 4 Lift the lancing device straight up be careful not to smear the blood on your testing site 5 Place the edge of the blood glucose test strip to the drop of blood cable 6 The blood will automatically draw into the channel of the blood glucose test strip You may get an inaccurate result if the blood sample is not completely filled in a single action 30 www infopia21 com Element 31 Replacing the Batteries Cleaning Your Meter and Maintenance Meter Your meter does not require special maintenance or cleaning Avoid getting dirt dust blood glucose control solution or liquids on the blood glucose test meter the test port or data port Your blood glucose test meter operation temperature is 10 C 40 c 50 F 104 F It is recommended that you store the meter in its carrying case after each use Acloth dampened wit
3. 4 i a25 The third latest The second latest The latest CE CE m 6 m4 5 m4 5 d Id d n 4 d Lin eld ein 21day average from the test date 14 day average from the test date 7day average from the test date Average test result Test Unit Test result amount Average test result days Element 27 Alternate Site Testing Performing a Blood Test Using and Alternate Site To ensure accurate results when lancing your forearm upper arm hand thigh or calf wash the test site with soap and water Upper Arm Forearm Dorsal Hand Ventral Palm Make sure there is no cream or lotion on the test site Thoroughly dry your hands and test site Thigh Fingertips Important Information About Using Alternative Sites Testing e Alternate sites where you can test are dorsal hand ventral palm upper arm forearm calf and thigh Under certain conditions blood glucose test results obtained using samples taken from your alternate sites may differ significantly from fingertip samples The conditions in which these differences are more likely to occur are when your blood glucose is changing rapidly such as following a meal as insulin dose or associated with physical exercise When blood glucose is changing rapidly fingertip samples show these changes more quickly than alternate sites samples When your blood glucose is falling testing with a fingertip sample may identify a hypoglycemic low
4. blood glucose level sooner than a test with an alternate sites sample Use alternate sites samples only for testing prior to or more than two hours after meal insulin doses or physical exercise Testing performed within two hours after meals insulin doses or physical exercise or whenever you feel that your glucose levels may be changing rapidly should be done from the fingertip You should also use fingertip testing whenever you have a concern about hypoglyce mia insulin reactions such as when driving a car particularly if you suffer from hypoglycemic unawareness lack of symptom to indicate as insulin reaction as forearm testing may fail to detect hypoglycemia CAUTION e To ensure accurate results when lancing your arm Upper arm or forearm leg calf or thigh or palm ventral palm or dorsal hand wash Important your hand and test site with soap and water We recommend that you test on your fingertips if you are testing for hypoglycemia e To receive accurate test results at least 0 341 minimum sample volume low blood glucose or if you are suffering from hypoglycemia unawareness is required 28 www infopia21 com Element 29 Performing a Blood Test Using and Alternate Site Element Blood Glucose Test Meter Software To bring fresh blood to the surface of the test site rub the test site vigorously You can transfer test results from the Element Auto coding blood glucose for a few seconds until you feel it getting warm
5. clockwise while holding the place base firmly 5 Put the tip of the lancing device back on and turn it clockwise 4 Twist the cap of the lancet off 7 Place the lancing device in place Hold it firmly against the side of the finger with the cap resting on the finger The harder it is pressed the deeper the puncture Press the release button to take a sample 8 Unscrew the tip of the lancing device by turning it counter clockwise 20 www infopia21 com 3 While holding the lancet carrier insert a new sterile lancet into the bottom of lancet carrier 6 Hold the tip firmly in one hand then pull out the sliding barrel with the other hand This will cock the lancing device 9 Push the lancet ejector forward with the thumb and simultaneously pull out the sliding barrel to dispose of the used lancet in a proper biohazard container Disposing of your lancet 2 Pull the lancet out and discard accordingly 1 Push the needle into the protective cover RECOMMENDED AVAILABLE LANCETS Some general sterilized lancets are BD Ultra Fine Cleanlet Fine E Z Ject G P Lite Microlet Monolet One Touch Soft Touch Therasense Ultra TLC and Unilet GP Note Some less known lancets may not work properly with the due to their dimensions Please contact your supplier to make sure you are using proper lancets USING THE CLEAR TIP AST 1 Place the lancing device on the skin in
6. infopia21 com The lancing device is a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood As a more advanced lancing device it provides ultimate safety and comfort for obtaining blood samples An adjustable tip offers 5 levels of skin penetration for individual user s comfort and a lancet ejector enables the safe disposal of the used lancet PRECAUTIONS e Never use a lancet that has been used by someone else This could lead to contamination e If the lancing device is to be used by another person the unit must be properly disinfected and a new tip and lancet must be used e Do not leave the lancet in the device after use e Anew lancet must only be placed into the lancing device directly before testing e This device has many small parts and could be a choking hazard for children if swallowed e In the case of hospital use hospitals need to consult their own infection control protocols in order to avoid any contamination e Always dispose of the used lancet in a biohazard garbage container COMPONENTS os Ejection System S Sliding Barrel Release Button Clear Tip Lancet Holder Depth Indicator Adjustable Tip Element 19 Collecting a Drop of Blood Collecting a Drop of Blood Unscrew the tip of the lancing 2 With two fingers pull out the device by turning it counter lancet carrier and hold it in
7. vial will appear on the bottom left hand side of the screen above the date and time This will allow you to differentiate between a glucose control solution test and an actual blood test for future reference 5 Dip the blood glucose test strip into the glucose control solution 6 Results appear in 3 seconds 7 Compare the result to the range printed on the blood glucose test strip vial the results should fall within that range 8 If your glucose control solution falls out of range do not perform a glucose test please contact your local representative 16 www infopia21 com Performing a Glucose Control Solution Test Note Element glucose control solution is sold separately It is recommended that glucose control solution is stored at room temperature 20 25 c 68 77 F before testing For example If you use a normal glucose control solution you must use the normal range printed on the side of the blood glucose test strip vial k Y__ amp w for Element _ s A 7 Glucose Control Solution Eaa n TA T OT Element A Ta ose Control ben e Results that fall outside the expected range may indicate e Test not performed at room temperature e An error in the way you are doing the test e Expired or contaminated glucose control solution e A problem with t
8. ER Number of days for average Alarm on off After pressing and releasing After pressing and releasing either either or W buttons to setthe 4 or W buttons to turn the alarm number of days for average on off confirm with calculation 3 different possible confirm with 7 gt mere ALI Oda a ALE Alarm time Alarm After pressing and releasing After programming the number of either or W buttons to setthe desired alarms 5 alarms possible alarm hour and minute confirm confirm with with Ch CAUTION 1 VERY IMPORTANT Correct test unit Your Element Auto coding blood glucose test meter is pre set to mmol L as test unit See also conversion table on page 39 2 Without setting the date properly the average glucose level and the results in memory will not show proper values It is recommended to set the meter before use and when new batteries are installed 3 Yon can t test your blood glucose while in the setting mode 4 To turn the meter off during setup press d for at least 3 seconds 14 www infopia21 com Auto Coding Function 1 Element Auto coding has automatic code recognition function 2 It recognizes automatically the code number This is a very convenient function preventing the inconvenience of setting the code number on the blood glucose test meter every time CAUTION 1 Do not bend the blood glucose test strip to prevent the Automatic code
9. FRAO am Element Blood Glucose Monitoring System Element APTE S INFOP LA Diabetes ManagementjT echnology Cees infopia Co Ltd El ment Blood Glucose Monitoring System Element Diabetes ManagementiTechnology Dear Element Blood Glucose Monitoring System Owner Thank you for choosing the Element Auto coding Blood Glucose Monitoring System This booklet has important information you must know about the Element Auto coding Blood Glucose Monitoring System Please read it carefully We understand that self testing of blood glucose level provides a way to control your diabetes and may give you peace of mind by testing regularly As a result Element Auto coding was developed to provide you with a fast and accurate reading with a convenient and simple process Our goal at Element Auto coding is to provide the best quality healthcare products coupled with superior customer service Always consult with your healthcare professional before making any changes to your diabetes management The Element Auto coding Blood Glucose Monitor ing System is for in vitro diagnostic use only Important information The Element Auto coding Blood Glucose Monitoring System is intended for use outside the body in vitro diagnostic use only It should be used only for testing blood glucose and only with fresh capillary whole blood samples It should not be used for the diagnosis of diabetes Consult yo
10. ction 32 www infopia21 com The low battery icon will appear in the upper left corner of the LCD screen to alert you when the battery power is running low indicating a new battery is needed Your Element Auto coding blood glucose test meter uses only two 3V Lithium batteries CR2032 which are included When replacing the batteries only CR2032 or equivalent lithium battery should be used After changing the batteries please be sure to recheck your meter settings lt Follow up Action gt 1 Check your meter with the glucose control solution p16 17 2 Perform your test again p22 24 3 If you are experiencing symptoms that are not consistent with your blood glucose test results call your healthcare professional Dispose of meter and batteries Dispose of meter The meter must be disposed of according to the local regulations concerning the disposal of electrical and electronic equipment The Waste Electrical and Electronic Equipment WEEE regulation implement provisions of the European Parliament and Council Directive 2012 19 EU aimed to reducing the amount of EEE waste going for final disposal The manufacturer has specific instructions for the recovery of the meter Please contact your distributor Dispose of batteries Please recycle or dispose of used batteries using your local battery collection systems and in compliance with your local environmental laws and regulations Batteries contain chemicals that
11. d be interpreted with caution Blood samples that contain a high concentration of dissolved oxygen may lower the test result Performance Characteristics The performance of Element Auto coding blood glucose test strips has been evaluated in laboratory and in clinical tests Please refer to strip manual for more details Measurement Range The measurement range of the Blood Glucose Monitoring System is 0 6 to 33 3 mmol L 12 www infopia21 com Setting Your Blood Glucose Test Meter The Element Auto coding Blood Glucose Test Meter has a variety of excellent functional modes beep sound to alert when function is set date time five daily alarms ability to designate activities related to the test result and the ability to designate three unique data averages J mm CU UE Power On User Activity Option Year Press for 3 seconds After pressing and releasing After pressing and releasing at least either or W buttons to turn either or buttons to set the year from 2007 to 2099 confirm with the user Activity option on off confirm with m a o LS ACT D Date Time After pressing and releasing either or W buttons to set the date and time confirm each with Cl Temperature unit Press and release either or W buttons to set F or C Enter 0 button Element 13 Setting Your Blood Glucose Test Meter gt ARAL i
12. dling Caution _ 6 7 8 9 Keep out of direct sunlight Store the Element Auto coding Blood Glucose Test Strip vials in a cool dry place between 2 30 36 86 Do not freeze Make a notation of the discard date on the vial label when you first open it Discard remaining Element Auto coding blood glucose test strips 6 months after first opening the vial Close the vial cap tightly immediately after removing a Element Auto coding blood glucose test strip Do not use test strips after the expiration date printed on the package or vial since it may cause inaccurate results Avoid getting dirt food or water on the blood glucose test strip Do not bend cut or alter the Element Auto coding blood glucose test strip Element Auto coding blood glucose test strips are for single use only Keep the blood glucose test strip vial away from children Please refer to the user s manual for Element Auto coding blood glucose test strip for additional information 10 Discard the used blood glucose test strip carefully to prevent any infection Use only Element Auto coding brand blood glucose test strip with your Element Auto coding blood glucose test meter Apply Blood Target Contact Bar Confirmation Window Element Element Blood Glucose Test Strip Information Limitations of System Element Auto coding blood glucose test strips provide accurate results when the fo
13. h water and mild detergent can be used to wipe down the outside of the blood glucose test meter Your Element Auto coding blood glucose test meter is a precision instrument Please handle it with care Lancet Device Clean the lancing device and caps with soap and tepid water To disinfect the lancing device prepare a disinfectant solution of one part household bleach to 10 parts water Dampen a cloth with this solution and wipe the lancing device thoroughly Soak only the cap for at least 30 minutes in the disinfectant solution Do not soak the lancing device in liquid Rinse the lancing device and cap with water and dry thoroughly e For detailed instructions concerning Element Auto coding blood glucose test strips refer to the test strip package insert found in the blood glucose test strip box e Please store the Element Auto coding blood glucose monitoring system in a cool dry area out of reach of children Do not freeze For a more accurate test result avoid testing under direct sunlight e Do not soak the blood glucose test meter or blood glucose test strips in water or liquid e Do not subject the blood glucose test meter or blood glucose test strips to excessive heat e Use your blood glucose test meter according to the instructions in the manual e If you need to purchase the lancing device lancets or blood glucose test strips contact your local representative e Discard the used Lancets carefully to prevent any infe
14. he blood glucose test meter e Glucose control solution that is too warm or cold e Failure to discard the first drop of glucose control solution and to wipe the bottle tip clean e Failure to shake the glucose control solution adequately CAUTION e If your glucose control solution falls out of range do not perform a glucose test please contact your local representative e The Glucose Control Solution range is not the recommended range for your blood glucose level Element 17 Testing Your Blood Preparation Collecting a Drop of Blood Before testing be sure to read this section and blood glucose test strip package insert found in the blood glucose test strip box carefully Make sure you have all the necessary items to begin testing e Element Auto coding blood glucose test meter e Element Auto coding blood glucose test strip e Lancing Device e Sterile Lancets CAUTION To reduce the chance of infection e The Lancing Device and sterile lancets should NOT be shared with others e Always use a new sterile lancet and new blood glucose test strip e Lancets are for single use only DO not reuse e Avoid getting hand lotion oils dirt or debris in or on the Lancets and the Lancing Device e Dry your hands completely before testing Practice using the lancing device and become accustomed with its use Wash your hands with warm clean water and soap Dry your hands completely before testing 18 www
15. her than 33 3 mmol L Please insert a new blood glucose test strip and perform your test again If the problem persists Please contact your local representative if the problem persists Place the blood glucose test meter within the operating temperature range for 10 minutes or more and retest Place the blood glucose test meter within the operating temperature range for 10 minutes or more and retest Check the accuracy of your blood glucose test strip by performing a glucose control solution test If the test results in a normal reading re test your blood sample two or three times If Lo persists consult your doctor immediately Check the accuracy of your blood glucose test strip by performing a glucose control solution test If the test results in a normal reading re test your blood sample two or three times If Hi persists consult your doctor immediately Element 3 Troubleshooting The blood glucose test meter does not power on Test does not start after applying blood sample The result is inconsistent Battery is dead or there is a problem with the blood glucose test meter Poor blood sample There may be a problem with the blood glucose test strip No readings in memory to display Not enough readings in memory to display designated averages 36 www infopia21 com Change the battery and if the problem persists please contact your local representative Please insert a ne
16. if released may affect the environment and human health The crossed out wheeled bin symbol indicates the need for the separate collection for batteries CAUTION Remove both batteries from the battery compartment and dispose of them according your institution s guidelines Element 33 The following chart may help you identify certain problems but may not solve all problems that can occur Please contact your local representative if the problem Action Required persists Message DAY MON Git tent Problem with the blood glucose test meter Caused by either used or wet blood glucose test strip Caused by less blood Blood glucose test strip is damaged User applied the blood sample before the LCD display ee E was blinking 34 www infopia21 com Place the battery again and set the blood glucose test meter If the problem persists Please contact your local representa tive if the problem persists Please insert a new blood glucose test strip and perform your test again Please insert a new glucose test strip and apply the blood sample Please insert a new blood glucose test strip and perform your test again Please wait for the LCD to display icon blinking before applying your blood sample Troubleshooting Problem with the Auto coding label The ambient temperature is too low The ambient temperature is too high The test result is lower than 0 5 mmol L The test result is hig
17. llowing constraints are observed Use only the Element Auto coding blood glucose test strips with the Element Auto coding blood glucose test meter e Use fresh capillary whole blood only Do not use plasma or serum e Do not use neonate samples e The blood glucose test strips are for single use only Do not reuse e Dehydration may lower test results If you are severely dehydrated contact your physician immediately e Inaccurate results may occur when in shock hypotensive individuals hyperglycemic or hyperosmolar state with or without ketosis e Element Auto coding blood glucose test strips may be used at altitude up to 10 000 feet without an effect on test results Physicians Please note the following interferences that may affect test results e Element test strip results can be used with hematocrit levels in the range of 20 to 60 If the hematocrit range is out of the range 20 60 then the test results may be lower or higher than actual value e Interferences Acetaminophen uric acid ascorbic acid vitamin C and other reducing substances when occurring in normal blood or normal therapeutic concentrations do not significantly affect results However abnormally high concentrations in blood may cause inaccurately high results Lipemic samples Cholesterol up to 500 mg dL or triglyceride up to 3000 mg dL do not significantly affect the results Glucose values however in specimens beyond these levels shoul
18. matically be drawn into the blood glucose test strip channel e When the chamber has enough blood your blood glucose test meter will automatically count down CAUTION 1 If the countdown does not start do not add more blood to the blood glucose test strip Discard the blood glucose test strip an restart testing 2 If you do not conduct the test within 3 minutes the blood glucose test meter will automatically power off to save battery life In this case you need to start the test procedure again from the beginning 3 You may get an inaccurate result if the blood sample is not completely filled in a single action Element 23 Testing Procedure Testing Your Blood Case of Setting User Option Step 3 e After beeping sound the test will begin automatically and your results will appear in 3 seconds It should begin counting down from 3 to 1 second on the LCD window The LCD window will display the result of your blood glucose level including temperature and time e Record the result value in your Element Auto coding logbook When you pull out the blood glucose test strip the meter turns off automatically CAUTION 1 If the test result is out of the test range the Hi Lo message will be shown on the LCD window refer to p35 2 Safely discard used blood glucose test strips and lancets 24 www infopia21 com Step 4 Z Lt 4 e If you selected to use the User Activity option aN o ams during set
19. ode number e A blinking blood glucose test strip will appear at the top of the screen indicat ing the blood glucose test meter is ready for testing Note Inserting the test strip in the wrong direction will turn the meter on but you will be unable to test CAUTION 1 If the code is not displayed after for a while pull the blood glucose test strip out of the port and re start the procedure from the beginning 2 If the code on the LCD display window and on the test vial does not match try another new blood glucose test strip If the mismatch persists please contact your local representative for help 3 If the meter does not power on pull the blood glucose test strip out of the port and re insert the blood glucose test strip 4 Avoid testing under direct sunlight for a more accurate test result 5 If you apply your blood sample too early ERRORS message will appear on LCD refer to p34 22 www infopia21 com Correct Applying Blood E Completely Filled Incorrect M Poorly filled sample size The Smallest Blood Sample Q e Apply your blood to the glucose test strip etd tal Rak at 0 and do not take off your finger until you get ne the beep sound The test will automatically start e Element Auto coding blood glucose test meter only requires 0 32 sample volume Step 2 e Place the top edge of the blood glucose test strip to the area you prepared for testing e The blood will auto
20. recognition failure 2 If the code recognition label is damaged the code recognition may fail Please check the code number on the LCD display window with the code number on the blood glucose test strip vial Element 15 Performing a Glucose Control Solution Test The glucose control solution should be used when there is suspicion that the blood glucose test meter or the blood glucose test strips are not working properly For example if strips have been exposed to extreme conditions or if you drop the blood glucose test meter Check the expiration date before performing a glucose control solution test Do not use if expired Once opened solution expires after 3 months The Glucose control solution should be used e Whenever you suspect the blood glucose test meter or blood glucose test strip is not functioning properly If your blood glucose test results are not consistent with your symptoms or if you think they are not accurate e If you have dropped the blood glucose test meter e For quality control in the point of care usage e For teaching or learning the system 1 Shake the glucose control solution before use 2 Discard the 1st drop of glucose control solution this will eliminate any residue 3 Place a drop of glucose control solution on a clean dry surface ex The lid of the blood glucose test strip vial 4 Insert a blood glucose test strip into the port and press the up arrow glucose control solution
21. the chosen area press and hold it continuously for a few seconds Then push the release button to take a sample 2 Watch through the clear tip until a sufficient blood sample is taken If there is not enough blood gently massage the area until a sufficient sample has been collected STORAGE Products must be stored at room temperature protected from sunlight or moisture CLEANING AND DISINFECTION Clean and wipe the outside of the lancing device a minimum of once a week with a soft cloth dampened with mild soap and water Wash the adjustable tip and the clear tip once a week with mild soap DO NOT immerse the lancing device in liquid WARRANTY Lancing device has a 2 year warranty from the date of purchase A malfunctioning device should be returned to the following address mal GMMC Room No 1112 Ace Tower 9th Bldg 345 30 Kasan Dong Kumchon Ku Seoul South Korea Tel 82 2 2104 0470 Fax 82 2 2104 0472 GMNC S L C Jordi de S Jordi 13 6 23 46022 Valencia SPAIN Tel 34 963 691 484 Fax 34 961 125 949 Element 21 Testing Procedure Testing Procedure Step 1 e Firmly insert the blood glucose test strip into the blood glucose test meter port with the infopia facing towards you e The blood glucose test meter automatically turns on displaying the code ambient temperature and the date and time e The Element Auto coding will automatically recognize the blood glucose test strip c
22. ting It should not be used for the diagnosis of diabetes or for the testing of newborns The Element Auto coding was designed to test a blood glucose sugar level and can be used with a capillary whole blood sample Do not use the Element Auto coding Blood Glucose Monitoring System for any other than for blood glucose testing CAUTION Before using any product please read all instructions Consult your physician or diabetic healthcare professional about daily management of your diabetes and proper use of the glucometer If you have any questions about the Element Auto coding product please contact Neon Diagnostics Ltd Freephone patient helpline 0800 009 3378 Muto codi Element 7 Element Blood Glucose Test Meter e Test Strip Port Insert the Element Auto coding test strip here Test Strip Ejector Display Screen Displays your test results symbols and messages Function Button Powers the meter on off prompts memory data and acts as an enter button during setup and after tests Up Down Arrow Buttons Adjusts setting scrolls through memory Serial Number 1 Element Auto coding Blood 6 Warranty Registration Card Glucose Test Meter 7 Patient Logbook Battery Cover 2 Element Auto coding Blood 8 Carrying Case Glucose Test Strips 9 Two 3V Li CR2032 Batteries 3 Lancing Device 10 Control Solution Normal 4 Lancets 5 Operation Manual CAUTION 1 Do not use Element Au
23. ting Separate collection for waste electrical and electorinic equipment Authorisd representative in the European community Waste batteries and accumulators 40 www infopia21 com Warranty Three Year Warranty If at any time during the first three years after purchase the blood glucose test meter does not work for any reason with the exception of obvious abuse misuse or disastrous damage infopia Co Ltd will replace your Element Auto coding blood glucose test meter or equivalence free of charge The Warranty Policy of infopia Co Ltd only applies to the original purchaser of the Meter and will not include the batteries supplied with the blood glucose test meter set Please fill in the warranty card attached to the set Mail or fax it back to us The Element Auto coding blood glucose test meter has a full three year warranty from the original date of your purchase For your convenience please include your date and place of purchase Element 41 ee ee Ywer infopia Co Ltd DIT sal infopia Co Ltd 891 Hogye Dong Dongan Gu Anyang ee eee enn ese eee cis cereale ec ede ee nee eae e Kyunggi 431 080 Korea www infopia21 com 0123 ecTREP Obelis S A Bd General Wahis 53 A ee se ee se meee ee T 1030 Brussels Belgium Tel 32 2 732 59 54 Fax 32 2 732 60 03 E Mail mail obelis net EEE E E E md Lancing Device GMMC Room No 1112 Ace Tower 9 Bldg 345 30 Kasan Dong K
24. to coding blood glucose test meter in a dry environment especially if synthetic materials are present Synthetic clothes Your Element Auto coding Blood Glucose Monitoring System has beens arts carpets etc may cause damaging static discharges in a dry environment shown above Please return the system to place of purchase or contact your 2 Do not use Element Auto coding blood glucose test meter near cellular or nearest Element Auto coding representative if the container seals are ie cordless telephones walkie talkies garage door openers radio transmitters or broken or parts are missing other electronic or electrical equipment that are sources of electromagnetic radiation as these may interfere with the proper operation of the blood glucose test meter 8 www infopia21 com Element 9 Element Blood Glucose Test Meter Display Element Blood Glucose Test Strip Information E CODEee 5 un y rere cone H a hal Dalil CHK AVR mmol L YR DAY MON Si S888 98 98 h gt YR DAY MON EET B888 mmol L c AVR 10 www infopia21 com Low Battery Warning Symbol Strip Code Symbol Blood drop symbol for test Alarm Symbol Before Having a Meal After Having a Meal After Sports Activity After Taking Medication Temperature Date Time Test Result Amount Test Result Unit Symbol Control Solution Symbol Average Test Result System Troubleshooting Symbol Storage and Han
25. umchon ku Seoul South Korea sal Lancet Sae Han Med Corp 973 16 Sungsuk Dong lIsandong Gu Goyang City Gyeonggi Do Korea C 0434 U K Distributor Neon Diagnostics Ltd Units 7 amp 8 Swanbridge Industrial Park Black Croft Road E E E E E E E E E ewes Se E ao E E EE RE E eee E E E Witham Essex CM8 3YN INFM21AGB 42 wwwinfopia21 com IMM20 516 Rev 2013 05 02
26. up press and W button to select oa ere the activity that correlates with your result refer E If 226 to p10 then press y e If you did not select to use user activity option during set up press to continue to step 4 2 CAUTION 1 If you did not activate the User Activity option Step4 procedure is not conducted 2 Please refer to page 13 if you want to set the User Activity option Element 25 Test Strip Ejector Function Reviewing Your Result Eject your blood glucose test strip Press and Push forward 1 Once the test is completed slide the ejector button forward to remove the blood glucose test strip from the blood glucose test meter 2 Discard the used blood glucose test strip and lancet accordingly CAUTION 1 If you push the ejector button forward too much it may cause the failure of the part 2 Do not give strong impact to blood glucose test meter 26 www infopia21 com The Element Auto coding blood glucose test meter stores up to 500 test results in its built in memory along with the average sugar level for the number of days which you had preset the blood glucose test meter to calculate These values can be retrieved on the LCD display at any time Press and release D button e Check your previous result by pressing the arrow W button Check your average data by pressing the arrow button yo mg Dl rr LI l R Lf 5 Ls a met 1220 meet 225
27. ur physician or diabetic healthcare professional about daily manage ment of your diabetes and proper use of the glucometer Please pay close attention when handling blood Improper procedures may cause serious hazards to your health The Element Auto coding Blood Glucose Monitoring System contains small parts Please keep your monitoring system out of reach of children 4 www infopia21 com Test Principle The enzyme glucose oxidase on the blood glucose test strip reads specifically with the blood glucose The current generated is converted and displayed as blood glucose value The Element Auto coding Blood Glucose Monitoring System is plasma calibrated to allow easy comparison of results with laboratory methods Blood glucose test meter which is calibrated against a whole blood method may have different results in comparison to Element Auto coding The laboratory system used for calibration of the Element Auto coding Blood Glucose Monitoring System is YSI 2300 STAT plus which is equipped with a glucuse oxidase system Note lt Maintaining the Element Auto coding blood glucose test meter gt 1 Do not assemble or disassemble the blood glucose test meter 2 It will have to keep in the place where the water does not reach 3 Avoid getting dirt and moisture 4 It does not have to keep in storage place of the chemical chemicals or the place where gas etc occurs 5 Keep out of direct sunlight Clement 5
28. w blood glucose test strip and perform your test again refer to the P 23 Please insert a new blood glucose test strip and perform your test again Troubleshooting Low battery symbol appears in the upper left corner of the LCD screen Cm Low battery warning symbol and 3 digit code Low battery Low battery Action Required Battery needs replacing For your free replacement batteries please contact Neon Diagnostics Ltd Freephone Patient Helpline 0800 009 3378 Battery needs replacing For your free replacement batteries please contact Neon Diagnostics Ltd Freephone Patient Helpline 0800 009 3378 Element Specifications Sample type Strip storage temperature Sample volume Test Range Operating Temperature Operating Humidity Dimension 76 X 56 X 18 mm Weight 45g Including Battery Power rating 3 V Li Battery CR2032 X 2 Battery Life One year after purchasing PC communications port Communication available 38 www infopia21 com Conversion table mmol L lt mg dL mg dL 60 70 72 80 85 90 100 108 110 mg dL 120 126 130 135 140 145 150 160 mode 1627170 1807 190 196 200 216 225 250 mg dL 375 400 414 432 450 475 500 540 600 Element 39 Symbol Reference Symbol Description Consult Instructions for use Es CEoix Temperature limitation CSD somme ic Date of Manufacture ee ly lt Keep away from sunlight For Self tes
Download Pdf Manuals
Related Search
Related Contents
Polycom 500 Telephone User Manual Playseats F1 PROTON Development Board MKII 15 LD 500 - lombardini service User`s Manual Manual do Portal de Serviços SIBS Manual de Operación y Mantenimiento Motores Serie N14 Plus Pioneer KRP-500A Flat Panel Television User Manual Samsung GT-E1080/I Benutzerhandbuch Copyright © All rights reserved.