DOSEVIEW™ 1D - Standard Imaging

image

Contents

1. aE Alignment lines aT Figure 4 Detector mount alignment lines stem shown transparent to show alignment Figure 5 Fully mounted detector DoseView 1D Setup and Operation Continued i 4 Filling the water tank Although the TG 51 protocol only requires a 20 0 cm travel depth the Standard Imaging DoseView 1D scanning arm has 27 5 cm of end to end travel distance The arm is intended to be used at a maximum of 25 0 cm depth with added space at the top to match the chamber depth to the water surface and provide adequate spacing at the full depth of 25 0 cm The tank label shown in Figure 6 shows the two minimum fill lines If only 20 0 cm of depth travel is desired simply fill water to at least the 20 0 cm fill line and likewise for the 25 0 cm fill line CAUTION Do not use the draining tube for filling the tank as the components are not rated for high pressure throughput 5 Setting the Origin Using the hand pendant see page 8 posi tion the detector carriage at the desired origin position To confirm the position press and briefly hold the SET ORIGIN button The display will show the current position as 0 Press and cm INITIALIZE hold to SET ORIGIN Peron mm 20 cm travel depth minimum fill line Figure 6 DoseView 1D tank minimum fill label NOTE The carriage can be driven into either rail end without risk However for maximum longevity of the scanning arm it
2. Arm submerged in water for extended periods of time is not covered under warranty There are no user serviceable parts on the DoseView 1D The warranty will become void if any component of the DoseView 1D is disassembled If assistance is desired in the proper disposal of this product including accessories and components after its useful life please return to Standard Imaging Parts and Accessories REF Description 91800 DoseView 1D Large Water Tank LxWxH internal 32 cm x 28 cm x 36 cm 91810 DoseView 1D Small Water Tank LxWxH internal 40 cm x 38 cm x 36 cm 70800 DoseView 1D Scanning Arm 80487 User s Manual 20193 Serial Extension Cable 100 ft DB9 M F 20194 Serial Extension Cable 25 ft DB9 M F 70850 PTW Markus Detector bracket 70851 Vertical Diode Bracket Min diameter 6 mm 0 24 in Max diameter 18 8 mm 0 74 in 76011 Universal Power Supply 12 VDC 1 25 A International Power Cord Kit UK EU Australia Markus is a registered trademark of PTW Freiburg Features and Specifications Dimensions DoseView 1D Scanning Arm Length Width Height Water Tank Internal Dimensions Length Width Height Water Tank material Weight 1D Scanning Arm Hand pendant Water Tank 30 x 32 x 36 empty Water Tank 40 x 42 x 36 empty Max scanning arm travel lonization chamber holder diameter accommodation Max chamber depth position backscatter Accuracy of position Repeatability of position O
3. Imaging Inc not later than seven 7 days after the expiration date of the warranty period in the table 3 which are returned to Standard Imaging Inc promptly after discovery of the defect and 4 which are found to be defective upon examination by Standard Imaging Inc Transportation related charges including but not limited to shipping customs tariffs taxes and brokerage fees to Standard Imaging are the buyer s responsibility This warranty extends to every part of the product excluding consumables fuses batteries or glass breakage or material reactions Standard Imaging Inc shall not be otherwise liable for any damages including but not limited to incidental damages consequential damages or special damages Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days This warranty is in lieu of all other warranties express or implied whether statutory or otherwise including any implied warranty of fitness for a particular purpose In no event shall Standard Imaging Inc be liable for any incidental or consequential damages resulting from the use misuse or abuse of the product or caused by any defect failure malfunction or material reactions of the product whether a claim of such damages is based upon the warranty contract negligence or otherwise This warranty represents the current standard warranty of Standard Imaging Inc Please refer to the labeling or instruc
4. is recom mended that this be avoided other than during initialization Also if a rail end is hit at fast speed the carriage must be moved away from the end at fast speed If the end is hit at slow speed either speed will move the carriage away from the rail end 6 Operating the scanning arm from outside of the treatment vault Disconnect the hand pendant from the scanning arm and in its place attach the provided 9 pin serial extension cable Run this cable outside of the treatment vault and re connect the hand pendant See Figure 7 The pendant will re power on display the current detector position and be ready for positioning the detector in the desired measurement location s Vault wall Figure 7 Hand pendant connection DoseView 1D Setup Continued 7 Draining the water tank Attach the included draining tube to the valve Press to release draining tube located at the bottom of the water tank The water will drain automatically Press the Insert draining round button on the valve to release the tube here draining tube See Figure 8 NOTE Water should be drained after each use to maximize the longevity and perfor mance of the scanning arm and water tank Figure 8 Water tank drain valve Using the Hand Pendant INITIALIZE button Press and hold to initialize the scanning arm This will also reset the origin to the top of scanning travel cm mm button Toggles the units shown on the pendant
5. rear of the arm and plug the unit into a wall outlet The two LEDs on the scanning arm indicate the following C 4 Standard Imaging Inc Middleton WI 53562 USA CAUTION Amber Power indicator AX 12v0t 1 25 4 POWER ZIN te oniy with provided power supply or Green Indicates successful self test AN ORC OR Pome by Standard Imaging Attach the hand pendant directly to the serial cable attached to the scanning arm The dis play will illuminate and initially show firmware versions for the arm robot and pendant Next Not Initialized will be displayed CAUTION Before initializing ensure no obstructions will impede the detector carriage To initialize press and briefly hold the INITIALIZE button on the pendant until Figure 1 DoseView 1D Scanning Arm the detector carriage begins to move The rear status hand pendant setup controls carriage will move to the top limit of arm and display travel and stop The arm carriage is now free to move 2 Aligning the water tank One side of the water tank does not have a black alignment line This is the side on which the scanning arm mounts Use the two black thumb screws to gently attach the arm ap proximately centered on the blank tank side Place the tank and arm onto the treatment couch Use the three vertical tank align ment lines to align the tank to isocenter using available treatment room laser lines Loosen the arm and move it until the light f
6. WWW STANDARDIMAGING COM The DoseView 1D fulfills the requirements set forth by the AAPM TG 51 Protocol for a single dimension water scanning phantom Determining the depth dose curve and SAD measurements are easily done with the system In addition various points at various depths are quickly measured for the check of machine parameters and characterization The DoseView 1D is a useful tool for dose assurance on a periodic basis A rotary encoder 1000 pulses per revolu tion is directly mounted to the leadscrew shaft This prevents the problems typically associated with an encoder mounted to the motor shaft which cannot take into account any backlash or elasticity in the mechanical linkage transferring the motion from the motor shaft to the leadscrew An encoder directly mounted on the leadscrew is only sensing what is critically important the direct movement of the leadscrew guiding the detector bracket Package Information This user manual covers the three packages in which Standard Imaging sells DoseView 1D components See below for the list of the major components and accessories included with each REF number REF 91800 REF 91810 REF 70800 Water tank 40x38x36 cm Water tank 32x28x36 cm Scanning arm Hand pendant Serial extension cable AC power adapter Draining tube Standard detector bracket DoseView 1D Setup and Operation at 1 Preparing the scanning arm Attach the AC power cable to the
7. arts which may be broken or missing or are clearly worn distorted or contaminated should be replaced immediately with genuine replacement parts manufactured by or made available from Standard Imaging Inc N CAUTION Federal law in the U S A and Canadian law restrict the sale distribution or use of this product to by or on the order of a licensed medical practitioner The use of this product should be restricted to the supervision of a qualified medical physicist Measurement of high activity radioactive sources is potentially hazardous and should be performed by qualified personnel CAUTION As desired by IAEA English is the default language for labeling and manuals If translated versions are available resolve any differences in favor of the English versions JN WARNING Proper use of this device depends on careful reading of all instructions and labels JN WARNING Where applicable Standard Imaging products are designed to be used with the versions of common radiation delivery devices treatment planning systems and other products or systems used in the delivery of ionizing radiation available at the time the Standard Imaging product is released Standard Imaging does not assume responsibility liability and or warrant against problems with the use reliability safety or effectiveness that arise due to the evolution updates or changes to these products or systems in the future It is the responsibility of the cus
8. diplay SET ORIGIN button Press and hold to set the current position as 0 Hand pendant display PROBE SPEED button Changes the speed of carriage motion between Fast Slow and D Step shown on the lower left of oo USJ GR the pendant display When Step is selected the STEP SIZE buttons become enabled DOSEVIEW ID STEP SIZE buttons When probe speed is set to Step the A and buttons will select between several conn step sizes shown on the lower right of ORIGIN the pendant display GO TO ORIGIN button Press to move the carriage Directional butt to the defined 0 position irectional buttons When probe speed is set to Fast or Slow press and hold either direction to move the carriage at the selected speed When probe speed is set to Step each button press will move carriage the selected step size distance 8 Maintenance Exterior cleaning of the device can be done with a soft brush and a cloth Gently brush all surfaces to remove dirt and dust Be especially careful that this is an external cleaning only and do not permit any liquid to seep into the DoseView 1D Scanning Arm enclosure or hand pendant in any manner during cleaning If the scanning arm will be stored while attached to the water tank all water should be drained after each use in order to maximize the longevity and performance of the scanning arm Dam age or corrosion caused by leaving the DoseView 1D Scanning
9. ided it is properly operated under conditions of normal use and that repairs and replacements are made in accordance herewith The foregoing warranty shall not apply to normal wear and tear or if the product has been altered disassembled or repaired other than by Standard Imaging Inc or if the product has been subject to abuse misuse negligence or accident Product Warranty Period Standard Imaging lonization Chambers 2 years Standard Imaging Well Chambers 2 years Standard Imaging Electrometers 5 years Standard Imaging BeamChecker Products 2 years Standard Imaging Software Products 1 year All Other Standard Imaging Products 1 year Standard Imaging Custom Products 1 year Standard Imaging Remanufactured Products 180 days Standard Imaging Custom Select Products 90 days Consumables 90 days Serviced Product 90 days Resale Products As defined by the Original Equipment Manufacturer ADGL Product Gabraton Di 90 800 100 of ADCL Calaten Cost and e Under warranty unless 183 365 days ous OADET Calibration Coni serine Soren ee ae Standard Imaging s sole and exclusive obligation and the purchaser s sole and exclusive remedy under the above warranties are at Standard Imaging s option limited to repairing replacing free of charge or revising labeling and manual content on a product 1 which contains a defect covered by the above warranties 2 which are reported to Standard
10. ield or laser line matches the white line on the detector bracket See Figure 2 Secure the scanning arm to the tank by tightening the two black thumb screws Do not overtighten the screws as a secure bal Figure 2 Detector mount alignment line ance can be achieved without much force DoseView 1D Setup and Operation Continued 3 Attaching a detector Figure 3 Attaching an ionization chamber For attaching a detector to the scanning arm follow the instructions below and refer to Figure 3 above 1 Select the desired detector and insert it into the hole in the blue detector bracket separated from the scanning arm 2 Tighten the white thumb screw to se cure the chamber into place 3 Insert the black rod of the detector mount assembly into the scanning arm s blue bracket Match the white alignment lines of both blue detector bracket pieces as shown in Figure 4 Align the detector with the light field adjusting the position from step 1 if necessary 4 Tighten the white thumb screw to se cure the assembly into place Any thimble ion chamber should fit into the detector bracket holder and most parallel plate chambers which have a rigid stem can be used with this detector bracket holder For parallel plate chambers simply insert the connector first into the holder feed the cable through and then tighten down the white thumbscrew when the chamber s stem is in position
11. ified on the outside of the package The customer must immediately file a claim with their carrier for any shipping damage or lost shipments Return shipping and insurance is to be pre paid or billed to the customer and the customer may request a specific shipper Items found to be out of warranty are subject to a minimum service fee of 1 hour labor excluding recalibrations for diagnostic efforts and require a purchase order PO before service is performed With concurrence from customer the product may be replaced if it is unserviceable or if the required service is cost prohibitive Products incurring service charges may be held for payment Standard Imaging does not provide loaner products See the Standard Imaging Warranty and Customer Responsibility for additional information Serialization Information Standard Imaging products that are serialized contain coded logic in the serial number which indicates the product day and year of manufacture and a sequential unit number for identification AYY DDD X A Unique product ID YY Last two digits of the year e g 1999 99 2000 00 DDD Day of the year 1 lt DDD lt 365 X Unique unit ID Number 1 lt X lt 9 Customer Responsibility eT This product and its components will perform properly and reliably only when operated and maintained in accordance with the instructions contained in this manual and accompanying labels A defective device should not be used P
12. n WWW STANDARDIMAGING 2 com DOSEVIEW ID REF 91800 91810 70800 STANDARD IMAGING INC 3120 Deming Way Middleton WI 53562 2532 TEL 800 261 4446 TEL 608 831 0025 FAX 608 831 2202 Wa Sep 2012 2012 Standard Imaging Inc STA NDA RD IMAG ING 4 DOC 80487 05 General Precautions CAUTION Warnings and Cautions alert users to Proper use of this device de dangerous conditions that can occur pends on careful reading of if instructions in the manual are not obeyed Warnings are conditions that can cause injury to the operator while Cautions can cause damage to the device and internal electronics all instructions and labels CAUTION Do not allow water or other liquids to enter the DoseView 1D Scanning Arm enclosure CAUTION Do not drop mishandle or disassemble this device Re fer all servicing to qualified individuals CAUTION Do not use the draining tube for filling the tank as the com ponents are not rated for high pressure throughput CAUTION Connector end of detector should not be submerged P i p Table of Contents PAGE 2 General Precautions 3 Overview 4 Package Information 5 DoseView 1D Setup and Operation 8 Using the Hand Pendant 9 Maintenance 9 Parts and Accessories 10 Features and Specifications 11 Service Policy 11 Customer Responsibility 12 Warranty Overview a s Wa STANDARDIMAGING 9 3120 DEMING WAY MIDDLETON WI 53562 1461 USA
13. perating conditions Pressure Temperature Relative Humidity Storage conditions Temperature Relative Humidity Power Requirements AC Output Product Standards 7 62 cm 3 0 in 20 32 cm 8 0 in 48 26 cm 19 0 in REF 91800 32 cm 12 60 in 28 cm 11 81 in 36 cm 14 17 in REF 91810 40 cm 16 54 in 38 cm 15 75 in 36 cm 14 17 in Clear acrylic 95 cm 3 8 in 1 36 kg 3 Ibs 0 23 kg 0 5 Ibs 6 35 kg 14 Ibs 10 43 kg 23 Ibs 27 5 cm 10 8 in Max 20 mm 0 79 in Min 6 mm 0 24 in 7 cm 2 76 in combined tank water 0 05 mm 0 002 in over the TG 51 range 200 00 mm 0 05 mm 0 002 in over the TG 51 range 200 00 mm 680 700 mm Hg 10 40 C 30 to 75 non condensing 40 70 C 0 to 95 non condensing 12 VDC 1 25A CE Specifications are subject to change without notice 10 Service Policy EE If service including recalibration is required please contact Standard Imaging s Customer Service department by phone or email prior to shipping the product Standard Imaging s Customer Service and Technical Service staff will attempt to address the product issue via phone or email If unable to address the issue a return material authorization RMA number will be issued With the RMA number the product can be returned to Standard Imaging It is the responsibility of the customer to properly package insure and ship the product with the RMA number clearly ident
14. tion manual of your Standard Imaging Inc product or the Standard Imaging Inc web page for any warranty conditions unique to the product 12
15. tomer or user to determine if the Standard Imaging product can be properly used with these products or systems Should repair or replacement of this product become necessary after the warranty period the customer should seek advice from Standard Imaging Inc prior to such repair or replacement If this product is in need of repair it should not be used until all repairs have been made and the product is functioning properly and ready for use After repair the product may need to be calibrated The owner of this product has sole responsibility for any malfunction resulting from abuse improper use or maintenance or repair by anyone other than Standard Imaging Inc The information in this manual is subject to change without notice No part of this manual may be copied or reproduced in any form or by any means without prior written consent of Standard Imaging Inc 11 Warranty _ _ _ X X eh _ _ _ _____ Standard Imaging Inc sells this product under the warranty herein set forth The warranty is extended only to the buyer purchasing the product directly from Standard Imaging Inc or as a new product from an authorized dealer or distributor of Standard Imaging Inc For a period provided in the table below from the date of original delivery to the purchaser or a distributor this Standard Imaging Inc product provided in the table is warranted against functional defects in design materials and workmanship prov