EC3-331 Coldroom Controller and ECD-001 Display Unit

image

Contents

1. EC3 331 Coldroom Controller and ECD 001 Display Unit Operating Instructions EMERSON Note This document contains short form instructions for experienced users Use last column in List of Parameters to document your individual settlings More detailed information can be found in the User Manual E a T AE ole ol i DIGITA A gt EC3 332 TCP IP C PCN 807 632 Y EMERSON Coldroom Contro ller EX5 6 7 8 yag Climate Technologies Rev 47050001 MAC ADDRESS 00 12 0A FD 03 2 r The EC3 331 is a dedicated controller for refrigerated coldrooms with superheat control and a driver for an Alco Controls Electrical Control Valve EX4 EX8 In addition the EC3 331 controls air temperature and manages defrost and fan s Network EC3 33x ALL RUTO eT TT TT TIT A PT4 pressure transmitter 4 and an ECN Pxx pipe temperature sensor 1 measure saturated suction gas pressure and suction gas temperature at the evaporator outlet and feed the signals into the superheat control loop The superheat controller output modulates the opening of the EX4 EX8 Electrical Control Valve 11 thus optimising the refrigerant mass flow through the evaporator The ECN Sxx air temperature sensor 2 measures air in temperature at the evaporator and feeds a signal into the air temperature thermostat The ECN Fxx fin sensor 3 is used for defrost termination Digital input 5 should be connected to the serial control loop of a compre
2. ECD 001 Display Unit Power Supply From EC3 331 via connecting cable Display 2 2 digit red LED with decimal point switchable between C and F LED indicators Compressor Fan Defrost Alarm IR status Temp amp Humidity Identical to EC3 331 specifications above IP65 front protection with gasket Connecting cable ECC N10 1 0m or CATS cable with RJ45 connectors Mounting The EC3 331 is designed to be mounted onto a standard DIN rail Mounting position on vertical walls with stepper motor connector on top side only 73 EMERSON _ er ECD 001 can be mounted in panels with a 71 x 29 mm cutout See dim drawing below for space requirements including rear connectors Push controller into panel cutout 1 Make sure that mounting lugs are flush with outside of controller housing Insert Allen key into front panel holes and turn clockwise Mounting lugs will turn and gradually move towards panel 2 Turn Allen key until mounting lug barely touches panel Then move other mounting lug to the same position 3 Tighten both sides very carefully until controller is secured Do not over tighten as mounting lugs will break easily EMERSON Cutout 71 x 29 mm PCN 864912 18 04 2011 EC3 331 Coldroom Controller and ECD 001 Display Unit EMERSON Operating Instructions Electrical Installation Refer to the electrical wiring diagram below for electrical connectio
3. Password PCN 864912 18 04 2011 EC3 331 Coldroom Controller and ECD 001 Display Unit EMERSON Operating Instructions Remarks r0 Door contact function 10 Cooling Temp alarm Function after delay time Ad O 8 a om i 9 f on 2 10 on off 320 o o Jo ee 4 12 on on dooralarm O pS o on _ dooralarm O 6 14 on off __ dooralarm and temperature alarmon __ 7 off off _ door alarm and temperature alarmon __ 13 off on dooralarmandcoolingon 15 off off door alarm and cooling on and temperature alarm on Alarm Codes E0 Pressure transmitter alarm EI Coil out sensor alarm E2 Air sensor alarm E3 Fin sensor alarm No sensor connected or the sensor and or the sensor cable is broken or short circuited Er Data error display out of range Data send to the display is out of range Ab Battery health failure Battery potentially does not have enough charge to close valve in an emergency Only reset by replacing battery Replacement kit 807 790 The use of the relay is essential to protect the system in case of power failure if the communications interface or the ECD 002 are not utilized Alarm status of the compressor serial loop feedback External compressor is active Serial safety loop is open circuit Ad Door open alarm AC AE Thermostat emergency operation Air sensor failure system is in continuous cooling mode AF Valve Status Valve closed due to compressor s
4. 7151 509 200 www emersonclimate eu EC3 331_65083_EN_R12 doc Replacement for Rev 11 4 4 PCN 864912 18 04 2011
5. EC3 Recommended Sensor Positions for Cold Room Applications ECN Pxx coil out temperature sensor 1 Position directly after the evaporator on the common suction line as shown below Insure proper thermal contact by using a metallic pipe clamp or temperature resistant plastic straps Do not use standard plastic tie wraps as used for electrical wiring as they may become loose over time which could result in faulty temperature measurements and poor superheat control performance It is recommended to insulate the coil out temperature sensor with ARMAFLEX or equivalent The recommended position of the pipe sensors is between 9 and 3 o clock as shown in the picture EC3_ColdDat cdr PT4 07M suction pressure transmitter 4 Position on the common suction line close to coil out temperature sensor 1 ECN Sxx air temperature sensor 2 Should be mounted on spacers in the middle of the air duct so that there is airflow around and positioned on the inlet of the evaporator as high as possible close to the ceiling ECN Fxx fin temperature sensor 3 Position on the evaporator asymmetric closer to the expansion valve Setup and Parameter Modification Using the Keypad of the ECD 001 For convenience an infrared receiver for the optional IR remote control unit is build in enabling quick and easy modification of the system parameters when a computer interface is not available Alternatively the parameters can be accessed via the 4 button key
6. responsibility to pass it to a designated collection point for the safe recycling of batteries harmonised directive 98 101 EEC For further information contact your local environmental recycling centre EC3 331_65083_EN_R12 doc Replacement for Rev 11 Technical Data EC3 Series Controller Power supply 24VAC 10 50 60Hz Class II 6 3mm spade earth connector 25VA max including EX4 EX7 28VA max including EX8 LonWorks Interface FTT10 RJ45 connector Removable screw terminals wire size 0 14 1 5mm Power consumption Communication Plug in connector size Ambient temperature range 0 60 C 1 25 C for best battery life time gt 35 C battery life time lt 2 years A order to provide system protection in the event of power loss it is recommended to change the battery annually i i keer 24VDC 4 20mA 4 20 mA analog output For connection to any 3 party controller with 12 24VDC power supply and appropriate burden Deviation from input signal 8 max Analog output 24VDC 4 20mA Digital Inputs 24V AC DC Output relays 4 Inductive AC15 250V 2A Alarm Comp SPDT contacts AgNi resistive AC1 250V 8A Heater Fan SPST contacts AgNi resistive AC1 250V 6A If the alarm relay is not utilized the user must ensure appropriate safety precautions are in place to protect the system against damage caused by a power failure Stepper motor output For EX4 EX8 Electrical Control Valves
7. 00 K 20 0 1 200 K 20 St Setpointday tt c 20 d DEFROST PARAMETERS Defrost mode Q natural defrost defrost heater not activated pulsed defrost not possible forced defrost defrost heater activated pulsed defrost possible forced defrost defrost heater activated pulsed defrost possible defrost termination using nviStartUp dl Termination by 0 termination by temperature termination by time will generate an alarm termination by time termination by temperature will generate an alarm first what ever comes first time or temperature no alarm last by time and temperature no alarm Caution can generate indefinite defrost periods Pulsed defrost O off no pulsed defrost heaters switched off at defrost termin ation temperature dt or max time dP whatever is selected 1 on pulsed defrost dd and dH in use heaters are switched off at dH and switched on again at dH dd Defrost at startup O no l yes 0 1 O Delay power up defrost O 180 min Of Pump down delay O 180 sec Compressor will run during pump down delay while valve is closed ojfjis mn 2 0 0 Injection delay 180 Valve is open during injection delay while compressor is not running Drain delay EC3 331_65083_EN_R12 doc Replacement for Rev 11 _dd Pulsed defrost differential _dP Max defrost duration F FAN PARAMETERS F1 Fan startup after defrost by 0 on 1 delayed by time Fd error on temperatu
8. afety loop active AH High temperature alarm AL Low temperature alarm AM ECV connection error Check connections to EX4 8 Electrical Control Valve Ao Superheat emergency operation Sensor s failure Au Valve open 100 for more than 10 minutes dt Forced defrost termination time or temperature Ft Forced fan startup time or temperature Emerson Electric GmbH amp Co OHG is not to be held responsible for erroneous literature regarding capacities dimensions applications etc stated herein Products specifications and data in this literature are subject to change without notice The information given herein is based on technical data and tests which EMERSON believes to be reliable and which are in compliance with technical Messages No data to display The display will show an the display In Reset to default values activated The display will show an In when the factory default configuration data set is initialized Id Wink request received The display will show a flashing Id when the wink request was received The flashing Id will be shown on the display until the service button will be pressed or a 30 min delay timer will expire or a second wink request is received OF Node is offline The node is offline and no application is running This is the result of a network management command and will happen for example during node installation dS Defrost standby dP Pump down df Defrost cycle dd Defr
9. ff l on 0 1 0 Temperature Unit _0 C 1 F 0 1 o Decimal point O yesl no 0 1 Oo 7 ECD display during defrost 0 2 0 0 dF defrost mode 1 dF defrost termination temp 2 dF control temperature C Temperature alignment for 1 0__ 20 0 200 K 0 0 A ALARM PARAMETERS A Low temp alarm dely o 180 mn s A2 High temp alarm delay 0 180 mm 5 A3 Alarm delay afer defrost 0 180 mm 10 aa Door alarm delay o 80 min 2 AH High temp alarm limi a 7 C7K 40 AL Low temp alarm imit ss AH C K 30 __ imi 0 1 At Alarm limit type 0 O absolute temperatures C 1 relative temperatures K to setpoint r THERMOSTAT PARAMETERS 10 Door contact function seepage 4 0 15 6 Min setpoint 50 2 C so 12 Setpoint max tl GO c 4 13 Day night control __0 off1 m 0 1 Jif r4 Thermostat mode off no thermostat function continues cooling air in sensor monitoring off no temp alarms generated cooling deadband control cutin set point difference cut out set point cooling modulating thermostat cutin set point cut out set point difference 2 heating deadband control cutin set point difference cut out set point on external control using nvi Valve via SNMP Air sensor monitoring off Temperature alarms will be generated 16 Setpointnight et 2 ec LAO 17 Differential night FO 2
10. m password The defrost cycle is activated Special Functions The Clear Alarm function has been replaced by the Special Functions mode The Special Functions can be activated by e Press M and IM together for more than 5 seconds a flashing 0 is displayed e Press J or M until the password is displayed default 12 If password was changed select the new password e Press SEL to confirm password e A 0 is ae and the Special Function mode is activated e Press to select the function The number of special functions is dynamic and controller dependent See list below e Press SEL to activate the function without leaving the special function mode e Press PRG to activate the function and leave the special function mode Most of the Special Functions work in a toggle mode the first call activates the function and the second call deactivates the function The indication of the function can only be displayed after exiting the special function mode e 0 Display test function e Clear alarm messages e 2 Cleaning mode The cleaning mode is effectively a manual defrost with the option of the fans on off The cleaning mode should not be used in order to isolate the application for maintenance purposes e 3 Fans only 4 Set the electronic control valve to 100 open e 5 Resets all parameters to the factory default setting The controller will indicate oF during the reset and the valve will close Displa
11. ns A copy of this diagram is labeled on the controller Use connection wires cables suitable for 90 C operation EN 60730 1 Ground the metal housing with a 6 3mm spade connector ee A S Pr aarm comp M HEATER g FAN DIGITAL OUTPUT 8 2 A 250 V STEPPER MOTOR e ole o Wi B BN for M12 type connector 1 3 4 2 DIGITAL OUTPUT 6 2 A 250 V for PG type connector EC3 331 LON C PCN 807 631 Coldroom Controller EX4 5 6 7 8 Rev 19070001 NeuronID 04A972390200 Made in Germany EMERSON Climate Technologies SUPPLY DIGITAL INPUT 24V 4 20mA TEMPERATURE 24V 1 2 1 1 2 50 60 Hz comp SUCTION COIL 1A SAFETY DOOR PRESSURE OUT AIR TERM 4 20mA T DEFROST SUCTION PRESSURE SJ Titi tT LLITEEEEEt O Vin Aout EC3 analog inputs are for dedicated sensors only and should not be connected to any other devices Digital inputs should only be connected to 24VAC DC Connecting any EC3 inputs to mains voltage will permanently damage the EC3 Important Keep controller and sensor wiring well separated from mains wiring Minimum recommended distance 30mm Warning Use a class II category transformer for 24VAC power supply EN 61558 Do not ground the 24VAC lines We recommend to use one transformer per EC3 controller and to use separate transformers for 3 party controllers to avoid possible interference or grounding problems in the power supply Connecting any EC3 inputs to mains voltage will permanently damage the
12. ost drain delay dI Defrost injection delay du Defrost start up delay Cn Cleaning CL Alarms are cleared at node start up and when no data is send to Visualising Data LON Monitoring Server The EC3 331 has a LON communication interface enabling the controller to be directly connected to a Monitoring Server Front view of RJ45 connector 87654321 PTO 2 amp hh BE h w 7 i _4y Gnd LONLON B A Neuron ID Service PIN The service pin is available on the ECD display It is used to identify the controller in a LON network Press the button for approx 1 sec to send the Neuron ID The LED in the left upper corner will indicate the transmission of the Neuron ID The default settings may be modified remotely from the EMS Monitoring Server via the LON network Consult the EMS user manual for more information It is also possible to display live graphical data on the server or to log data containing the control temperature at defined intervals knowledge of today It is intended only for use by persons having the appropriate technical knowledge and skills at their own discretion and risk Since conditions of use are outside of EMERSON s control we cannot assume any liability for results obtained or damages occurred due to improper application This document replaces all former versions Emerson Electric GmbH amp Co OHG Postfach 1251 HeerstraBe 111 D 71332 Waiblingen Germany Phone 49 0 7151 509 0 Fax 49 0
13. pad The configuration parameters are protected by a numerical password The default password is 12 To select the parameter configuration e Press ia PRG button for more than 5 seconds a flashing 0 is displayed e Press 4 or be until the password is displayed default 12 if password was changed select the new password e Press SEL to confirm password The first modifiable parameter code is displayed 1 To modify parameters see Parameters modification below EC3 331_65083_EN_R12 doc Replacement for Rev 11 Parameter Modification Procedure e Press or be to show the code of the parameter that has to be changed e Press aay to display the selected parameter value e Press 4 or be to increase or decrease the value e Press SEL to temporarily confirm the new value and a its code e Repeat the procedure from the beginning press to show To exit and save the new settings e Press PRG to confirm the new values and exit the parameters modification procedure To exit without modifying any parameter e Do not press any button for at least 60 seconds TIME OUT e Press ESC on IR remote control Defrost Activation A defrost cycle can be activated locally from the keypad e Press the be button for more than 5 seconds a flashing 0 is displayed e Press or M until the password is displayed default 12 if password was changed select the new password e Press SEL to confir
14. re 2 by temperature Ft error on time 3 first whatever comes first time or temperature no alarm 4 last time and temperature must come no alarm go cong ___1 gt o 3 gt 0 on 1 off 2 delayed by F4 3 off when door open F3 Fan during defrost O on t o o 1 Jop Fa Siop dayim S 30 mjo FS Fan during cleaning Ozom izon 0 1 0 Fd Fan delay after defro o 30 mn 0 Fe On temp aferat opo eo C COMPRESSOR PARAMETERS Delay first start EA C2 Min stoptimeit C3 Min runtime tO u SUPERHEAT PARAMETERS 0 Refrigerant 0 R22 1 R134a 2 R507 3 R404A 4 R407C 5 R410A 6 R124 7 R744A Correction glide dp positive values Pressure drop negative values MOP control u u u u u Glide 0 MOP off 1 MOP on MOP temperature 4 Superheat mode 0 0 off 1 fixed superheat 2 adaptive superheat 3 fixed superheat slow 4 adaptive superheat slow Rev gt 25 Superheat init setpoint Superheat setpoint min Superheat setpoint max u9 Start opening delay Rev gt 23 0 60 1 Valve type uF 100 max valve opening 100 ECD display 100 uF 50 max valve opening 50 ECD display 100 Logic for door contact input 0 24V means door open 1 0V means door open 0 all disabled Caution access to controller only via the LON network 1 Keyboard enabled 2 IR remote control enabled 3 Keyboard and IR remote control enabled
15. ssor where applicable and digital input 6 should be connected to the coldroom door contact The controller has 4 relay outputs to control the compressor 7 defrost heater 8 evaporator fan 10 and an external alarm device 9 Please consult the technical data right for input and output ratings The EC3 331 features an integral backup battery to close the electrical control valve in case of power loss Due to the positive shut off characteristics of the EX4 EX8 Electrical Control Valves a liquid line solenoid valve is not needed to prevent flooding of the compressor The optional ECD 001 Display Unit 13 can be connected to the EC3 331 for local display of control parameters and for controller setup without the use of a PC Because the EC3 331 is fully functional without display unit the ECD 001 may be removed at any time A Safety instructions e Read installation instructions thoroughly Failure to comply can result in device failure system damage or personal injury e The product is intended for use by persons having the appropriate knowledge and skills e Ensure electrical ratings per technical data are not exceeded e Disconnect all voltages from system before installation e Keep temperatures within nominal limits e Comply with local electrical regulations when wiring e The EC3 series contains a lead acid gel rechargeable battery The battery must NOT be disposed of with other commercial waste Instead it is the users
16. y of Data The data to be shown on the display can be selected by the user In case of an alarm the alarm code is displayed alternately with the selected data The user can inhibit the alarm code Press the SEL button to scroll through all possible displayable data The display will show for one second the numerical identifier of the data and then the selected data After two minutes the display will return to the by parameter 1 selected data It is possible to temporarily display the values of the different sensors This is a useful feature when initially setting up the system without the aid of the WebPages Press the SEL sequentially The value displayed on the screen corresponds to the number corresponding to the 1 parameter Action only valid when parameter H2 3 IR LED Logical status of compressor relay LON activity LED only active when service pin is pressed Logical status of fan relay Logical status of defrost heater relay Alarm condition 274 PCN 864912 18 04 2011 EC3 331 Coldroom Controller and ECD 001 Display Unit EMERSON Operating Instructions List of Parameters DISPLAY PARAMETERS Value to show 0 6 0 0 Thermostat control temperature with Temp alignment C 1 Defrost termination temperature C 2 Coil in temperature C calculated from the pressure 3 Coil out temperature C 4 Calculated superheat K 5 Valve opening in 6 Displays defrost status 2 Alarm suppression O o