1.    Always check the voltage selector on the PSU to ensure that it is set to the proper voltage  available in your country     Connecting the PSU to the TUBECORE 3U is fairly easy  thanks to industrial standard 8 pin  metal connector and long  heavy duty cable     Always power up the PSU first and then use power switch at the front of the TUBECORE 3U   Follow the reverse order when switching off     About the tubes    As one of the TUBECORE 3U s main features is the possibility of replacing tubes  we have  placed them outside the unit  Please  be aware of this fragile parts and do not place the  TUBECORE 3U close to the wall or cables hanging from the back of the other gear in your 19  inch rack     IGS AUDIO TUBECORE 3U     stereo vari mu mastering compressor    The TUBECORE 3U is a full symmetric transformer balanced stereo mastering compressor  The  structure is based on the typical vari mu solution  Apart from the classic INPUT  THRESHOLD  and OUTPUT controls it introduces switchable high pass filter in the sidechain  parallel  compression  MIX knob   independent ATTACK and RELEASE switches and an user  replaceable tubes accessible from the back of the unit     The TUBECORE 3U compressor allows you to work either in dual mono or mid side mode   M S   The Mode switch has two bypass positions     they both work the same  but we added  them for your comfort and quick A B comparing     Every single TUBECORE 3U is hand made with high quality  matched components  1  metal  film 
2.    TUBECORE    MASTERING EDITION       TUBECORE 3U    USER S MANUAL    IGS Audio Igor Sobczyk  3 Maja 76d  41 400 Mystowice  Poland  e mail  igs o2 pl ph   48 601 597 592    www igsaudio com    Please read all of the following instructions and save them  for later reference before attempting to connect the unit to the mains     EARTH  This unit is connected via its power cord to the mains safety earth   NEVER OPERATE THE UNIT WITH THIS EARTH CONNECTION REMOVED        COVERS  DO NOT remove the covers  Refer servicing to qualified personnel only     VOLTAGE  Unit is set to operate only at the voltage indicated on the PSU unit  CHECK that the correct voltage is selected before connecting the AC mains supply     FUSES  CHECK that the fuse fitted is the correct type for the local mains voltage   ALWAYS replace fuse with the correct type        MOISTURE  DO NOT expose the unit to rain or moisture  If the unit  should become so exposed REMOVE the mains power immediately     CABLES  PROTECT the mains power cord from damage though impact or abrasion     HEAT  ALWAYS site the unit away from sources of heat including direct sunlight and ensure  adequate ventilation around the unit        Mi civics   AVIS A    RISK OF ELECTRICAL SHOCK  DO NOT OPEN   RISQUE DE CHOC ELECTRIQUE  NE PAS OUVRIR     CAUTION  TO REDUCE THE RISK OF FIRE OR ELECTRICAL  SHOCK  DO NOT EXPOSE THIS PRODUCT TO RAIN OR  MOISTURE  TO REDUCE THE RISK OF ELECTRICAL  SHOCK DO NOT REMOVE TOP OR BOTTOM COVER   REFER SERVICIN
3.  PE 5 l    5     q z         4       16  WY 4 k HA LA 4      o      e  at joy  as ve    o  OUTPUT  4       MODE HPF    GR METER    GAIN    OUTPUT    THRESHOLD    ATTACK    RELEASE    HPF  MIX    MODE    STANDBY    ATTACK RELEASE STANDBY    Clearly visible coil meter to ensure that the amount of gain  reduction applied is easy to read     This is the make up gain knob  You can adjust the amount of  signal at the input of TUBECORE 3U     Output level control     Above this level of the input signal the compression will occur   Use it to control the amount of compression  The amount of  reduction applied can be read on the GR meter     Time delay between the appearance of the signal and the  compressor reaction     Time delay between the disappearance of the signal and the  compressor reaction     Introduce high pass filtering in the sidechain circuit     Set the balance between compressed and uncompressed  signal     parallel compression     Choose between working in stereo mode or mid side  then the  left channel becomes the Mid signal  and the right becomes the  side signal   In bypass mode the whole unit is bypassed     Master standby switch for the unit  In standby mode no signal  goes thru  After switching the TC3U on  allow the unit to warm  up for a couple of minutes  tubes heating     TUBECORE 3U main functions and technical specification     a Si Si SO CD GO  Sh OG    3U stereo unit with M S functionality  Fully symmetric audio path    Carnhill input transformer    Sow
4. ELECTRIC SHOCK  DO NOT OPEN  A  SERIAL No     e e LEFT  www igsaudio com ia e p Sonne  oy  MADE IN POLAND z 4 oe  6N1P EW LEFT  TUBECORE 3U OUTPUT i ZEROM E AE A   POWER    5670  6N1P EW RE    Warranty     This device is declared to be free from defects in material and workmanship for a period  of three years  Any device found defective within three years from the delivery date and  returned to the factory  will be repaired  adjusted  or replaced and sent to the customer  with no charge  The customer always pays the shipping cost to us  This warranty does  not cover expendable items such as tubes or fuses  If the defect has been caused by a  misuse or abnormal operation conditions  the repair will be billed at a nominal cost  The  product should be returned in its original package  if this is possible  or packed in such a  way that it is not damaged during the shipment  We are not to be held responsible for  any damages during the shipment  19  units shall always be packed in a box with  support for the rack ears  All 500 series modules need to be secured in ESD bag and  protected with foam  We will charge the customer    20   VAT if the packing material needs  to be replaced  If we find that the product works perfectly  the customer will be invoiced     50   VAT to cover our costs of examination and handling plus the cost for returning the  product to the customer        www igsaudio com    
5. G TO QUALIFIED SERVICE PERSONNEL        Copyright 2014  All rights reserved    The information in this document is subject to change without notice    IGS Audio makes no warranty of any kind with respect to the material in this document  and shall not be liable for errors contained herein or for incidental or consequential    damages related to the use of the material     Manual revision  1 0  July 2014     R  IGS    Thank you for buying this IGS Audio product        Please read the information provided below very carefully before using your IGS unit     Unpacking  Your TUBECORE 3U has been carefully and meticulously tested and inspected before dispatch     Please check for any signs of transit damage  If any signs of mishandling are found please  notify the carrier and your dealer immediately     Your TUBECORE 3U packing should contain an TUBECORE 3U with IGS Audio tag  an  TUBECORE 3U POWER SUPPLY unit and this manual with the Warranty and RoHS CE WEEE  Declaration attached     Compatibility and Power  The TUBECORE 3U uses dedicated external POWER SUPPLY unit and can t operate without it     Never attempt to replace the external PSU with the third party one or one made by yourself     There is a fuse socket near the power cable connector on the PSU  Ensure that the correct fuse  is being used before plugging the TUBECORE to the power outlet       gt  For US area  115V  use 2A Slow Blow  Type T      gt  For Europe and rest of the world area  230V  use 1A Slow Blow  Type T   
6. edure below     No signal plays thru the unit  regardless the settings at the front panel       Please check the cables connecting the rack       Check if the tubes are placed correctly  There are differences in signal level between channels after tube replacement       Make sure you have used matched pair of tubes      Please follow the Calibration Procedure after the tube swap  In M S mode the GR Meters show different reduction         in most cases the MID channel is louder than SIDE signal  Use the TUBECORE 3U  controls to adjust the levels    Tube Replacement and Calibration Procedure     Remember to use matched tubes of the correct type  The calibration is needed to set the bias  and    zero point    on the GR meters     1  Make sure the Tubecore 3U is turned off    2  Gently remove old tubes and replace them with new ones  Ensure you don t bend any of  the pins  Place your new tubes in appropriate sockets  Never put more than 4 tubes in the  TUBECORE 3U     Turn on the unit and wait approx  15 minutes to warm up the tubes   Use small screwdriver to set 0dB  trim pots under ZERO METER holes for both channels     Your Tubecore 3U is now calibrated     O PvP 37     In some cases  especially if the tubes haven t been matched  It might be impossible to set     0dB    on the meters  It is recommended to try different set of tubes          AlddNS YAMOd NE 340938NL     gt  a ZERO METER  TRIMPOTS  LOCATION    y    S39VI10A  ANd LNO    Yy    z  a  Li    CAUTION   LEFT A RISK OF 
7. resistors  Wima caps   It is equipped with 6N1P EW NOS tubes and individually calibrated  to give you the unique and unspoiled experience of one of the best vari mu compressors in the  history  It is equipped with Carnhill and Sowter audio transformers  We have spent hundreds of  hours designing the TUBECORE  to make sure that it is as simple to use as it is versatile     The sound qualities of the TC3U can be changed by changing the tubes in the back of the  device  You can achieve the following effects     6N1P EW     standard set of tubes     standard    compression   6BC8 6BZ8     tight  transparent  punchy compression   6386     legendary compression  by famous twin triode   5670     deep and dark tube compression     KRKA    It is important to use matched tubes for best channel convergence  You can also use different  tubes for Mid and Side channels     feel free to experiment  There is no risk of damaging the  Tubecore 3U once you put correct tubes in correct sockets  However  it might be necessary  to calibrate the unit after the tube swap  You can do it on your own  follow the Calibration  Procedure chapter  or let the qualified personnel to do it for you     Block diagram           M S  decoder   with bypass     GR METER         M S  coder   with bypass          MIX BYPASS    dry wet         BALANCED    INPUT BALANCED    OUTPUT           GAIN RED   AMPLIFIER   HPF  attack   release         TUBECORE 3U BLOCK DIAGRAM    GR METER GAIN THRESHOLD OUTPUT MIX    a a ws wk 
8. ter output transformer    Hard wired bypass    Sidechain HPF   Dry Wet knob for parallel compression  All stepped manipulators   XLR input and output   Large VU meter with LED back light  External PSU unit for low noise   3 year warranty       Operating Level     4dBu       Maximum Input     22 dBu       Maximum Output     22 dBu       Input impedance    600 Ohm       Output Impedance    600 Ohm       Standard used    6N1P       Max Gain Reduction    20 dB       Maximum Gain    35 dB       Attack Time    0 1     30 ms       Release Time    0 1 4s       Frequency response    20Hz to 20kHz      0 2dB       THD N  0dBu    0 002                          Noise level dBA    110dB  Power consumption   44 Watts  Shipping weight   7kg  Dimensions   H 13 3cm x W 7 6 cm x D 18cm  Troubleshooting    My unit doesn t light up  the VU meter is dark          Please check if the rack PSU is on and the switch at the front of the unit is in ON position        Check the PSU and power cables      Check the fuses    The signal plays thru but there is no change in signal when i turn the knobs         Please check the Mode  Stereo   m s   bypass  switch position   it should be set to       Stereo    or    Mid Side            Check the Mix knob   it should be in Wet position  turn it fully clockwise        With no signal applied  the VU meter doesn t show O0dB         Please use the small screwdriver to set the zero calibration trim under the holes at the  back of the unit  check the Calibration Proc
    