Home

Ariston E-Combi_User_Manual Boiler Manual

image

Contents

1. Should the boiler fail toignite a second time check that the external gas cock is open If the problem persists contact an Authorised Service Centre Supplied By www heating spares co Tel 0161 620 6677 his Document Has Been Provided By HEATING SPARE or Winter or summer operating modes I IN In jihereene operating mode the boiler will produ ot ce both Central Heating and Domestic Hot Water In the summer operating mode the boiler will produ ce only Domestic Hot Water Using the knob on the control panel the user can select winter or sum mer operating mode Keeping the knob 5 at the O position selects the summer operating mode Win ter operating mode may be selected by positioning the knob 5 between the min and max settings Adjusting the heating It is possible to set the temperature of the heating water by adjusting the knob 5 By positioning the indicator somewhere between min and max a temperature may be obtained which varies from about 40 C to about 82 C The water temperature in the primary circuit may be checked by means of the green leds 1 Domestic hot water temperature adjustement It is possible to set the temperature of the domes tic hot water by adjusting the knob 6 a temperature may be obtained which varies from about 36 C to about 60 C Switching off the heating To switch off the heating mode turn the button 5 in the position O The boile
2. blink Check the water pressure on the pressure gauge 4 and make sure that is between 0 6 and 1 5 bar when the system is cold If the pressure is just under the minimum refill the system by open the valve under the boiler If the pressure drops very frequently there may be a water leak at some point in the system If this is the case a plumber should be contacted Operation shutdown This type of error is non volatile which means that it is not removed automatically the red led 8 will illuminate and the C H Temperature led 1 will indicate the error code In this case the boiler does not restart automatically but it may be reset by pressing the eset button If the problem manifests itself again after several attempts to reset the appliance contact a qualified technician Important If this shutdown occurs frequently contact an authorised service centre for assistance For safety reasons the boiler will allow a maximum of 5 reset operations to take place in 15 minutes individual presses of the button If the shutdown is occasional or an isolated event this is not a problem Temporary shutdown due to defective discharge of exhaust fumes The boiler is fitted with safety devices which in the event of a defective discharge of exhaust fumes automatically interrupts the gas supply there by shutting off the boiler The shut off of the boiler is temporary and is indicated by the illuminationof the yellow led 9 for a peri
3. clock S30 00 SION OB Od NE a Reset button Initial operating procedures If the boiler is installed inside the apartment make sure that all provisions relating to the air inlet and room ventilation in compliance with current legislation are respected Check the water pressure on the pressure gauge regularly and make sure that the figure is between 0 6 and1 5 bar when the system is cold If the pressure is just under the minimum value re establish the correct pressure by filling loop If the pressure drops very frequently there may be a water leak at some point in the system If this is the case a plumber should be contacted Ignition procedure Press the ON OFF button on the control panel to switch on the boiler Green indicator CH temperarure and errors indicator Winter Summer switch Heating temperature regulation knob Domestic Hot Water adjustment knob Green indicator flame ON Red indicator locking light Yellow indicator fumes exhaust malfunction The green led 3 will illuminate indicating that the boiler is ready to operate The electronic control unit will ignite the burner without any manual intervention but in response to the request for Domestic Hot Water or heating If after approximately 10 seconds the burner has not ignited the boilersafety devices will shut off the gas and the red Led 8 illuminates To reset the ignition system the Reset button must be pressed and released
4. connected to a heating system and a distribution network for domestic hot water both of which must be compatible with its performance and power levels The use of the appliance for purposes other than those specified is strictly forbidden The manufacturer cannot be held responsible for any damage caused by improper incorrect and unreasonable use of the appliance or by the failure to comply with the instructions given in this manual Installation maintenance and all other interventions must be carried out in full conformity with the governing legal regulations and the instructions provided by the manufacturer Incorrect installation can harm persons animals and possessions the manufacturing company shall not be held responsible for any damage caused as a result In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories switch the appliance off by switching the external bipolar switch to the OFF position and shutting off the gas valve When the work has been completed ask a qualified technician to check the efficiency of the ducting and the devices If the boiler should be out of use for a prolonged period it is recommended that the electrical power supply be disconnected and that the external gas cock be closed If low temperatures are expected the boiler and system pipe work should be drained in order to prevent frost damage Turn the
5. the boiler is electrically powered there is a supply of gas Supplied By www heating spares co Tel 0161 620 6677 user manual Table summarising error Green Leds Note Temperature indicator i A Reset Description O flashing light 40 50 60 70 80 90 yellow red lit e X_ Overheat ejo X_ Insufficient circulation ojlo O Insufficient water request filling ojo O C H Flow temp probe circuit open short circuit ojlo O C H Return temp probe circuit open short circuit e e O External sensor circuit open short circuit O O O Floor Thermostat contact open ejo o X_ Heating delevery probe problem ojo O Insufficient circulation 0 O EEPROM error O O Comunication error ojojojoljo O Too many gt 5 resets in 15 minutes e X _ Main P C B error O O O Room sensor circuit open short circuit e X_ No flame detected ojojo O Flame detected with gas valve closed ejoj o o X Flame lift ie 0 0 O 1st Ignition Failed Ojo ie O 2nd Ignition Failed ojojo O Flame cut off ejo e X_ Thermofuse open e e X_ Fan speed error Change of gas type Our boilers are designed to function either with Natural Gas methane or L P G gas If you need to change from one gas to the other one of our Authorised Service Centres must be contacted to convert the appliance Maintenance Schedule an annual maintenance chec
6. E COMBI Gas fired condensing wall hung combination boilers G C N 47 116 62 24 kW G C N 47 116 63 30 kW G C N 47 116 64 38 kW E COMBI 24 E COMBI 30 E COMBI 38 we ee EET ee approved product penchman THE MARK OF QUALITY FOR THE INSTALLATION COMMISSIONING Cou ntry of destination GB ME EATE ED AND SERVICING OF DOMESTIC HEATING AND HOT WATER SYSTEMS Supplied By www heating spares co Tel 0161 620 6677 Thank you for choosing an ARISTON boiler We guarantee that your boiler is a reliable and technically sound product This manual provides detailed instructions and recommendations for proper installation use and maintenance Remember to keep this manual in a safe place for future reference i e by the gas meter Your local MTS Servicing Centre is at your complete disposal for all requirements The installation and first ignition of the boiler must be performed by qualified personnel in compliance with current national regulations regarding installation and in conformity with any requirements established by local authorities and public health organisations After the boiler has been installed the installer must ensure that the end user receives the declaration of conformity and the operating manual and should provide all necessary information as to how the boiler and the safety devices should be handled This appliance is designed to produce hot water for domestic use It should be
7. boiler off and turn the external switch OFF to clean the exterior parts of the appliance Do not allow children or inexperienced persons to use the appliance without supervision 2 CE labelling The CE mark guarantees that the appliance conforms to the following directives 90 396 CEE relating to gas appliances 2004 108 CEE relating to electromagnetic compatibility 92 42 CEE relating to energy efficiency 2006 95 CEE relating to electrical safety Supplied By www heating spares co Tel 0161 620 6677 user manual HEAT List The appliance is guaranteed for 24 months from the date of purchase Aristons only obligation under the guarantee will be to repair or replace the faulty appliacnce at Aristons discretion This will be carried out where the fault arises from within defects in the appliance caused either by material or workmanship of the manufacturer This guarantee does not protect malfunction or damage arising from incorrect installation commissioning or maintenance procedures as laid out in the installation and servicing manual inefficient flue system poor or incorrect electricicty wrong gas supply or pressure tampering by inexperienced persons and any other cause not directly due to manufacture MTS GB Limited cannot accept responsibility for any cost arising from repair or maintenance carried out by any third party Service under the guarantee does not affect the expiry date o
8. f the guarantee The guarantee on parts and appliances which are exchanged ends when the guarantee on the original appliance expires This guarantee does not affect your statutory rights You must have your boiler serviced at the end of the first year to validate your guarantee for the second year Safety regulations Key to symbols Do not climb onto chairs stools ladders or unstable supports to clean the appliance A Failure to comply with this warning implies the h risk of personal injury in some circumstances Personal injury caused by falling from a height even fatal or cuts step ladders shutting accidentally A Failure to comply with this warning implies the Do not attempt to clean the appliance risk of damage in some circumstances even without first switching it off and turning the serious to property plants or animals external switch to the OFF position Do not perform operations which involve Electrocution from live components opening the appliance Do not use insecticides solvents or aggres A Electrocution from live components sive detergents to clean the appliance Personal injury caused by burns due to ove Damage to plastic and painted parts rheated components or wounds caused by Do not use the appliance for any use other sharp edges or protrusions than normal domestic use Do not perform operations which involve Damage to the appliance caused by operation removing the appliance from its
9. installation overload space Damage caused to objects treated inappro AA Electrocution from live components priately 3 o Flooding caused by water leaking from discon Do not allow children or inexperienced indi nected piping viduals to operate the appliance Explosions fires or intoxication caused by gas Damage to the appliance caused by improper leaking from disconnected piping use lf you detect a smell of burning or smo Do not damage the power supply cable ke coming from the appliance disconnect A Electrocution from live uninsulated wires it from the electricity supply turn off the Do not leave anything on top of the ap main gas valve open all windows and call pliance for assistance A Personal injury caused by an object falling off Personal injury caused by burns smoke inhala the appliance as a result of vibrations tion intoxication Damage to the appliance or items underneath If there is a strong smell of gas turn off the it caused by the object falling off as a result of main gas valve open all windows and call vibrations for assistance Do not climb onto the appliance Explosions fires or intoxication AA Personal injury caused by the appliance fal ling Damage to the appliance or any objects un derneath it caused by the appliance falling away from its installation space Supplied By www heating spares co Tel 0161 620 6677 Legend ON OFF button Green indicator ON OFF Pressure gauge Time
10. k up for the boiler with a competent person Correct maintenance always results in savings in the cost of running the system Failure to arrange an annual service for the appliance will invalidate the second year of the manu facturers guarantee Supplied By www heating spares co Tel 0161 620 6677 This Document Has Been Provided By HEATING SPARES Please Visit www heatingspares co or call us on 0161 620 6677 For Spares at Discounted Prices Mrs GRO Commercial subsidiaries MTS GB Limited MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone 01494 755600 Fax 01494 459775 Internet www mtsgroup com uk E mail info uk mtsgroup com Technical Advice 0870 241 8180 Customer Service 0870 600 9888 Professional Team Limited Suites 9 amp 10 Plaza 256 Blanchardstown Corporate Park 2 Ballycoolin Dublin 15 Telephone 01 810 3723 Fax 01 810 3727 Internet www mtsgroup com ie E mail info ie mtsgroup com Technical Advice 01 437 0121 Customer Service 01 437 0121 Supplied By www heating spares co Tel 0161 620 6677 420010127500 02 2008
11. od of about 12 minutes Once this time period has passed and the discharge state of exhaust fumes has returned to normal the boiler automatically turns back on A IMPORTANT If this situation occurs frequently contact an Authorised Service Centre So that they may check that the exhaust fumes are being expelled correctly and that the area is ventilated properly Anti frost Device The anti frost function acts on the central heating flow temperature probe independently from other regulations when the electrical supply is turned on If the primary circuit temperature is between 3 C and 8 C the pump will run with the diver ter valve switching between central heating and hot water every 1 minute until the temperature reaches gt 9 C If the flow temperature remains between 3 C and 8 C the pump will continue to run for a maximum of 20 minutes unless a temperature above gt 9 C is de tected in the central heating flow after this the the burner will fire heating position until a temperature of gt 30 C is detected If the central heating flow temperature is lt 3 C the burner will fire heating position at minimum power until the temperature reaches gt 30 C the burner will go out If lockout is caused by overheat the burner will not fire but the pump will continue to run heating po sition The anti frost device activates only when with the boiler operating correctly the system pressure is correct
12. r switches in sanitary mode only Stand by To switch off the boiler press the ON OFF 2 The res pective green led 3 will go off Switch off the boiler completely by switching the external electrical switch to the OFF position Close the gas tap Supplied By www heating spares co Tel 0161 620 6677 Boiler protection device The boiler is protected from malfunctioning by means of internal checks performed by the electronic microprocessor P C B which stops the boiler from operating if necessary In the event of the boiler being shut off in this manner the leds code show the type of shut off and the reason behind it There are two types of shut off Safety shut off This type of error is volatile which means that the boiler starts up again automatically as soon as the problem which caused the shut off is removed the yellow led 9 flash and the C H Temperature leds 1 indicate the error code see table In fact soon as the cause of the shut off disappears the boiler starts up again and continues to operate normally If the boiler still indicates a safety shut off switch it off Make sure the external electric switch is in the OFF position shut off the gas valve and contact a qualifi ed technician Shutdown due to insufficient water circulation If the green leds 1 flash and the boiler is off one possible cause for this stateis an insufficient pressure of water in the system green leds 40 50