Home
COMPACT4448D User Manual
Contents
1. 1 810 Fig 2 Circuit Legend Microprocessor Nonvolatile Memory Communications Chip Quartz Crystal Power Supply Capacitor Voltage Regulator Output Port Buttons 9 16 Keypad S1 Fade Rate Selector S2 Special Mode Selector For 2 G Panels 0 2 825 72 gt C4448DUM Rev A 09 01 Digital Lighting systems COMPACT 44 48D 70S anual Pose 3 Installation Instructions See Figs 3 4 amp 5 below 1 Install the COMPACT 44 48D in a convenient location Fig 3 shows an COMPACT 48D AE which has a female XLR connector mounted on the side of its aluminium enclosure COMPACT 48D models may be mounted in deep double gang masonry boxes and have a pigtail for data connections See Fig 5 below 2 Provide a standard power outlet with a toggle switch for the wall transformer Plug the supplied transformer to the COMPACT 44 48D using the Molex connector plugs The COMPACT 8D may remain energized at all times 3 Install the DMX dimmer pack and follow the wiring instructions in its user manual 4 Connect the COMPACT 44 48D to the Dimmer Pack using the DMX cable DMX CC LEN to either internally mounted COMPACT 48D AE or externally mounted XLR connector COMPACT 48D on request and COMPACT 44D see Fig 4 Skip to Operating Instructions 9V Wall Adapter 1 Molex Plugs 2 3
2. Printed in U S A Rev A 09 01 Digital Lighting systems COMPACT 44 48D 290 Operating Instructions COMPACT 48D Four Channels Eight Scenes Adjusting Channel levels Adjust channel levels by pressing and holding their respective up or down button until each level ramps up or down to the desired value For fine adjustments momentarily press and release the appropriate button This limits changes in levels to an increment or a decrement of 1 step out of 256 The LED associated with the up button stays on when its corresponding level reaches 100 while the down LED stays on when the level reaches 0 Both LED s remain on otherwise Preset Scenes Panel without Front Cover Presets must be un locked to enable this operation see paragraph below BUTTON To store a scene 1 Adjust the channel levels for a particular scene number 2 Press and hold the corresponding scene button 3 When the panel s LED s flash release the button To recall a scene 1 Select the button of the scene you wish to recall 2 Momentarily press and release the button The LED associated with the preset button that was actuated last remains on while all others turn off 4 amp 8 Locking Unlocking Presets Buttons Presets automatically re lock upon panel reset or power up To Unlock and Enable Storing the 8 Presets ToAccess RESET button gently 1 Hold down the panel s RESET button or de energize panel pry front cover from panel u
3. 15 KV on data input and output Non Volatile Memory Storage Of Banquet Halls 2 800 4 600 1 650 a PD408 DMX DIMMER PACK Single 071 mm 117 mm 042 mm The COMPACT 44 48D require an external dimmer pack and a DMX cable Any DOMER TASD 4 600 4 600 1 650 Double DMX 512 compatible dimmer pack may be used Digital Lighting Systems Inc 117 mm 117 mm 042 mm manufactures high quality low cost DMX 512 dimmer packs The PD408 DMX is an 480 4 600 4 600 2 500 Double excellent companion to the Compact xxD panel It can drive four 960 Watt 120 VAC AE 117 mm 117 065 mm loads at 50 and 60Hz 12 24 220 VAC versions are also available DEPTH D includes circuit board with components 7588 NW 8th Street Miami Fl 33126 e Tel 305 264 8391 or 1 877 264 8391 Fax 305 261 6637 casagpum Copyright 2001 Digital Lighting Systems All rights Reserved Specifications are subject to change without notice Printed in U S A Rev A 09 01 Digital Lighting Systems COMPACT 44 48 Four Zone DMX Panels User Manual Page 2 Deep Metal Masonry Box by others Masonry Box Must Be Properly Grounded Network Bus 2 1 2 n io Inside Clearance Circuit Height J8FXLR5 L Pigtail DMX 512 Adapter Fig 2 COMPACT 44 48D Mounting Diagram Screws 2 6 32x 1 amm 1 400 36 mm Typical
4. 4 Digital Lighting Systems Miami USA digitalighting com DMX CC LEN Fig 3 COMPACT 48D Installation Drawing COMPACT 44 48D DMX and Power Connections Fig 4 COMPACT 44 48D with external The COMPACT 44 48D panels use a standard 5 Pin Female XLR J8FXLR5 L installation Drawing connector to connect to DMX equipment as seen in Figs 4 amp 5 They are also available on request with an unterminated pigtail that plugs into the back of the unit so that customer may make their own DMX connections or with a pre terminated cable with XLR connector to the customer s desired length J8FXLR5 L An external transformer SRI supplies power via a 2 pos Molex type connector 1 i 1 OV Wall Power and DMX pin assignments are shown in Fig 5 Fere 3 Adapter 4 Fig 5 DMX Output Pin Assignments TIL To Port 7 L lt gt On Back Of Panel Molex Plugs TO DMX Equipment 12345678 5 Pin Female XLR Connector J8FXLR5 L K XLR Connectors To DMX Ground Shield d Dimmer Packs DMX CC LEN J8FXLR5 L L Length in feet 7588 NW 8th Street Miami Fl 33126 e Tel 305 264 8391 or 1 877 264 8391 Fax 305 261 6637 casagpum Copyright 1999 Digital Lighting Systems All rights Reserved Specifications are subject to change without notice
5. operate properly in this mode Setting S2 to position F causes the COMPACT 44 48D controllers to output a 4 byte DMX packet on channel addresses 1 to 4 only The PD408 DMX dimmer pack made by Digital Lighting systems will operate properly with the standard 512 byte packet and with the shorter 4 byte DMX packet Setting S1 to position 0 causes instantaneous transitions between scenes regardless of the position of S2 Use a small tip screw driver to rotate the shafts of S1 amp S2 to the desired positions Standard DMX Packet S2 set to O DMX Header Chan 1 Chan 2 Chan 3 Chan 4 Chan s 5 512 Idle Short DMX Packet S2 set to F DMX Header Chan 1 Chan 2 Chan 3 Chan 4 Figure 6 DMX Output Packet Formats 51 Fade Time Instantaneous 40 06 Seconds 37 95 Seconds 35 84 Seconds 33 73 Seconds 31 63 Seconds 29 52 Seconds 27 41 Seconds 25 30 Seconds 23 19 Seconds 21 08 Seconds 18 98 Seconds 08 43 Seconds 08 43 Seconds 08 43 Seconds 08 43 Seconds With S2 set to 0 51 0 1 2 3 4 5 6 7 8 9 A B C D E F Fade Time Instantaneous 31 63 Seconds 29 52 Seconds 27 41 Seconds 25 30 Seconds 23 19 Seconds 21 08 Seconds 18 98 Seconds 16 87 Seconds 14 76 Seconds 12 65 Seconds 10 54 Seconds 08 43 Seconds 06 33 Seconds 04 22 Seconds 02 11 Seconds Table 1
6. replacement or repair of any units as shall within one year of date of invoice from Digital Lighting Systems prove defective and Digital Lighting Systems shall not be liable for any other damages whether direct or consequential The implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the expressed warranty Some states do not allow the exclusion of the limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights you may also have other legal rights which vary from state to state Defective merchandise may be returned to Digital Lighting Systems prepaid after prior notification has been given and approval obtained for the return To obtain prior approval for the return of the defective items contact your local Digital Lighting Systems distributor representative or Digital Lighting Systems Inc Attn Customer Service Department 7588 NW 8th Street Miami FL 33126 305 264 8391 Upon request replacement unit s will be shipped as soon as available Unless immediate shipment of replacement merchandise is requested Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received inspected and determined to be defective No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written appr
7. Cover Mounting requirements Wiring Notes e he COMPACT 48D mounts in double gang deep masonry box or may be ordered in a table top aluminum enclosure The Female XLR connector comes mounted on the side of the enclosure The COMPACT 44D mounts in a single gang masonry box e Both types of masonry boxes must have a minimum depth of 2 1 2 and a minimum inside height of 2 15 16 to allow clearance for printed circuit All wiring between the COMPACT 44 48D panel and dimmer packs is low voltage NEMA Class 2 and must be a shielded twisted pair cable Standard industry DMX 512 cables may be used with the panel Do not run DMX cable in the same conduit with non class 2 circuits The panels are supplied with an external low voltage wall adapter Power for the adapter may be on a different power phase from power supplying the DMX 512 dimmer packs or fixtures Installation must conform to local and or NEC code requirements board See above illustration e Use Grounded metal boxes only Ordering Information COMPACT 48D COMPACT 48D AE COMPACT 44D J8FXLR5 L 4 Channel 8 Scene Panel 2 G size With Aluminum Table Top Enclosure 4 Channel 4 Scene Panel 1 G size DMX 512 XLR Adapter Pigtail L no of 7588 NW 8th Street nan FI 33126 e e Tel 305 264 8391 or 1 877 264 8391 Fax 305 261 6637 lt 1 810 46 mm gt lt Additional Circuitry
8. Digital Lighting Systems Inc COMPACT 44 48D Series Four Zone Multi Scene Wall Box DMX Panels MODEL NUMBERS Compact el 8 Scene ane ZONES SCENES e Compact 48D 9 9 e Compact 48D AE E e Compact 44D H 2 16 HH eH F O O L fart 8 ing Systems SA digitallighting com USER S MANUAL C4448DUM Rev A 09 01 Digital Lighting systems COMPACT 44 48D 70S Compact 48D 4 Channel 8 Scene DMX Panel SCENES H 9 igital Lighting Sys D PACT 44D COMPACT 48D aibi on INTRODUCTION The COMPACT 48D is a four channel DMX dimmer control panel with 8 scene presets It is designed to mount a 2 gang masonry box and is also available in a table top aluminum enclosure Each channel has a pair of control buttons a RAISE and a LOWER to adjust its DMX value The COMPACT 48D features PRESET buttons for storing and recalling 8 separate lighting scenes Preset scenes may be locked once stored in the panel s non volatile memory The COMPACT 48D is one of the smallest and most unique 4 channel 8 Scene DMX panel in the industry requiring the same wall space as a standard heavy duty wall box dimmer See masonry box dimens
9. Fade Rate Table 2 Fade Rate With S2 set to Should you require any further information regarding the Selector S2 Packet Speed Selector Sset to Short DMX Packet Selector 51 Fade Speed Selector Using a small tip screw driver rotate the shaft and position the arrow at the desired number Valid range 0 F See Tables 1 amp 2 above COMPACT 44D or COMPACT 48D or any other Digital Lighting Systems products do not hesitate to contact the factory at 305 264 8391 Set to 0 Standard DMX Packet 12 PAP R S2 EOS EOS S1 or email at See Fig 6 above info digitallighting com Fig 7 OPTIMA number of Channels and Chase Fade Selection gt Digital Lighting Systems Lighting Control Excellence since 1978 WWW DIGITALLIGHTING COM 7588 NW 8th Street Miami Fl 33126 Tel 305 264 8391 or 1 877 264 8391 Fax 305 261 6637 C4448DUM Copyright 1999 Digital Lighting Systems All rights Reserved Specifications are subject to change without notice Printed in U S A Rev A 09 01 LIMITED WARRANTY Digital Lighting Systems warrants to the purchaser that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended Any abuse or misuse contrary to normal operation shall void this warranty Digital Lighting Systems obligation under this warranty shall be limited to
10. ions on page 2 The COMPACT 4D is a four channel DMX dimmer control panel with 4 scene presets It is designed to mount a single gang masonry box Each channel has a single control button that functions as a RAISE and a LOWER alternately The COMPACT 44D features PRESET buttons for storing and recalling 4 separate lighting scenes Preset scenes may be locked once stored in the panel s non volatile memory The COMPACT 44D is one of the smallest and most unique 4 channel 4 Scene DMX panel in the industry requiring the same wall space as a standard wall box toggle switch See masonry box dimensions on page 2 Fade Rate between scenes may be adjusted using a rotary selector on the back of the panels The COMPACT Series is ideal for controlling the emerging new DMX compatible Fluorescent ballasts GENERAL FEATURES APPLICATIONS Physical and Electrical Specifications e Economical e Office Buildings Back Plate Metal Construction Compact Wall Mount Panels Dimensions See Table Below 4 Channel 8 Scene Double Gang Hotel Conference Rooms Power Max 80 mA at 10 VAC 50 60 Hz Version Houses Of Worship Data Output RS485 Compliant 4 Channel 4 Scene Single Gang Schools and Universities Output Drive 256 1 8 DMX Loads Version Museums and Art Data Format Standard DMX 512 Protocol Simple Pushbutton Operation Gallanes Data Retention 10 years no batteries required Channel and Preset LED Indicators ESD Protection
11. oval from the factory Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems Digital Lighting Systems Inc 7588 NW 8th Street Miami FL 33126 www digitallighting com Tel 305 264 8391 Fax 305 261 6637 e m info digitallighting com Printed in U S A September 2001
12. sing 2 Simultaneously press and hold down preset buttons 4 amp 8 a small tip screw driver applied to 3 Release the RESET button or re energize panel LED s will flash once the notch located at the bottom 4 Release Preset buttons 4 amp 8 LED s will flash again to indicate that presets have been unlocked Operating Instructions COMPACT 44D Four Channels Four Scenes Adjusting Channel levels Each of the four channels this unit controls has a corresponding button for raising and lowering that channel Channel levels may be adjusted by pressing and holding their respective button until each level ramps up or down to the desired value For fine adjustments momentarily press and release the appropriate button This limits changes in levels to an increment or a decrement of 1 step out of 256 Pushing and holding a button causes the level of the corresponding output to vary in one direction Releasing the button and pressing again causes the output level to vary in the reverse direction Preset Scenes Panel without Front Cover Presets must be un locked to enable this operation see paragraph below RESET To store a scene s 1 Adjust the channel levels for a particular scene number Bek o o 2 Press and hold the corresponding scene button I 3 When the panel s LED s flash release the button 5 To recall a scene S H 1 Select the button of the scene you wish to recall 2 Momentarily press and release the but
13. ton The LED associated with the preset button that was actuated last remains on while all others turn off b uttons Locking Unlocking PresetsPresets automatically re lock upon panel reset or power up 4 amp 8 To Unlock and Enable Storing the 4 Presets 1 Hold down the panel s RESET button or de energize panel ToAccess RESET button gently 2 Simultaneously press and hold down buttons 4 amp 8 pry front cover from panel using 3 Release the RESET button or re energize panel LED s will flash once a small tip screw driver applied to 4 Release buttons 4 amp 8 LED s will flash again to indicate that presets have been unlocked the notch located at the bottom 7588 NW 8th Street Miami Fl 33126 e Tel 305 264 8391 or 1 877 264 8391 Fax 305 261 6637 casagpum Copyright 1999 Digital Lighting Systems All rights Reserved Specifications are subject to change without notice Printed in U S A Rev A 09 01 Digital Lighting Systems COMPACT 44 48 Scene Fade Rate Instructions COMPACT 44 48D Four Zone DMX Panels User Manual Page 5 Scene Fade Rate Selection The fade rate between scenes is adjustable using rotary selectors 51 and S2 See Fig 7 below for 1 and S2 locations With S2 set to position 0 fade times from 8 43 to 40 06 sec s may be achieved See Table 1 Faster fade rates may be achieved by setting S2 to position F See Table 2 However DMX dimmer packs not manufactured by DLS may not