        ACD-10 Pro and ACD-10 TRMS Pro Product Manual
         Contents
1.                               uw    I         W                      CAUTION    Measuring Resistance  Continuity  Diode or Capacitance function on a live circuit will  produce false results and may damage the instrument  In many cases the suspected    component must be disconnected from the circuit to obtain an accurate measurement  reading     8  Q Resistance  and       Continuity functions  Inputs are made through the test leads terminals  Slide switch on defaults at Q  Press  SELECT button momentarily to select      Continuity function which is convenient for  checking wiring connections and operation of switches  A continuous beep tone  indicates a complete wire        Diode test function   Inputs are made through the test leads terminals  Slide switch on defaults at Q  Press  SELECT button momentarily 2 times to select  gt   Diode test function  Normal forward  voltage drop  forward biased  for a good silicon diode is between 0 400V to 0 900V  A  reading higher than that indicates a leaky diode  defective   A zero reading indicates a  shorted diode  defective   An OL indicates an open diode  defective   Reverse the test  leads connections  reverse biased  across the diode  The digital display shows OL if the  diode is good  Any other readings indicate the diode is resistive or shorted  defective         Capacitance function   Inputs are made through the test leads terminals  Slide switch on defaults at Q  Press  SELECT button momentarily 3 times to select      Capacitanc
2.  reading digits   number of digits  or otherwise specified  at 23  C   5  C   amp  less than 75  R H        Model ACD 10 PRO TRMS  True RMS accuracy of ACV is specified from 5  to 100   of range  and ACA is specified from 10  to 100  of range  or otherwise specified   Maximum Crest Factor  lt  1 75   1 at full scale  amp   lt  3 5  1 at half scale  with frequency  components within the specified frequency bandwidth for non sinusoidal waveforms     DC Voltage  ACD 10 PRO TRMS PRO  Accuracy  0 3    4d  0 5    3d    NMRR    gt 50dB   50 60Hz   CMRR    gt 120dB   DC  50 60Hz  Rs 1kQ   Input Impedance   10MQ  30pF nominal   1000MQ for 400 0mV range     AC Voltage  ACD 10 PRO TRMS PRO             OHZ    500Hz    1 5    5d   2 0    5d  CMRR    gt 60dB   DC to 60Hz  Rs 1kQ  Input Impedance   10MQ  30pF nominal       Max Hold  where applicable   Specified accuracy   50 digits for changes  gt   2oms in duration    Audible Continuity Tester  Audible threshold   between 20Q        1200     Capacitance  ACD 10 PRO TRMS PRO    RANGE   500 0nF  5 000pF   3 5       6d    50 00uF  500 0uF   3000uF        Additional 50 00nF range accuracy is not  specified     Accuracies with film capacitor or better       Specified with battery voltage above 2 8V   approximately half full battery   Accuracy  decreases gradually to 12  at low battery  warning voltage of approximately 2 4V       13  AC CURRENT  ACD 10 PRO TRMS PRO    Accuracy 1           1 9    8d   Accuracy specified to 350A continuous  and  4
3. 00A for 60 second max with 5 minutes cool  down interval     Added range to indicate instantaneous  over range current values    OHMS  ACD 10 PRO TRMS PRO    RANGE Accuracy  400 0Q    0 8    6d  4 000      40 00kQ  0 6    4d  400 0kQ  40 00MQ 2 0    4d    Open Circuit Voltage   0 4VDC typical          Diode Tester  ACD 10 PRO TRMS PRO    Open Circuit Voltage   Test Current     Typical      lt  1 6 VDC 0 25mA  Hz Frequency  ACD 10 PRO TRMS PRO   Sine RMS     00 0mV   150      10Hz    2kHz  000V 5Hz    40kHz            100kHz  SHz    100kHz  SHz    5    2  Display counts  5000   Best resolution  0 001Hz   Accuracy  0 5  4d       14    LIMITED WARRANTY    Your AMPROBE instrument has a limited warranty against defective materials and or  workmanship for one year from the date of purchase provided that  in the opinion of the  factory  the instrument has not been tampered with or taken apart     Should your instrument fail due to defective materials  and or workmanship  during this one year period  please have your dated bill of sale  which must  identify the instrument model number and serial number and call the number  listed below     Repair Department  ATP   AMPROBE  MIRAMAR  FL  Tel  800 327 5060  www amprobe com       SPX  G    Advanced Test Products  Miramar  FL  Tel    954 499 5400  Fax   954 499 5454       ED PRINTED ON RECYCLABLE PAPER  PLEASE RECYCLE  COPYRIGHT    MMII Btc  ALL RIGHTS RESERVED  P N 7M1C 0461 0000 PRINTED IN TAIWAN    
4. Frequency functions    Inputs are made through the test leads terminals  Slide switch on defaults at DC voltage   Press SELECT button momentarily to select AC voltage     Press the Hz push button momentarily to activate Hz Frequency function in the following  slide switch functions     DCV  amp  ACV via the test leads  ACA via the jaw clamp    6  Note  DC 400 0mV range is designed with 1000MQ high input impedance for least  current drain in measuring small signals  and can cope better with most commercially  available voltage output transducers adapters  The non zero display reading is normal  when the meter inputs are open circuit  which will not affect actual measurement  accuracy  The meter will show close to zero reading when the inputs are shorted  Open  input is actually a floating condition  which is not a zero volt input condition     Note  Hz input sensitivity varies automatically with function range selected while  activating the Hz function  Lowest range has the highest sensitivity  and the highest  range has the lowest sensitivity  Activating the Hz function while measuring the specific  function signal  auto ranging  can automatically select the best sensitivity range to avoid  electrical noise which may cause unstable Hz reading  However  if the Hz reading shows  zero due to insufficient sensitivity  activate the Hz function BEFORE measuring the  specific function signal  The meter is then in the lowest range and can select the highest  sensitivity              
5. INSTRUCTION MANUAL  ACD 10 PRO  amp  TRMS PRO          AN                    1  Congratulations  You are now the owner of an AMPROBE Instrument  It has been  quality crafted according to quality standards and contains quality components and  workmanship  This instrument has been inspected for proper operation of all of its  functions  It has been tested by qualified factory technicians according to the  long established standards of AMPROBE     1  SAFETY   This manual contains information and warnings that must be followed for operating the  instrument safely and maintaining the instrument in a safe operating condition  If the  instrument is used in a manner not specified by the manufacturer  the protection  provided by the instrument may be impaired     The meter meets the requirements for double insulation to IEC61010 2 032  1994    EN61010 2 032  1995   UL3111 2 032  1999      ACD 10 PRO TRMS PRO  Category 11 600 Volts ac and dc   Category 111 300 Volts ac and dc     PER IEC61010 OVERVOLTAGE INSTALLATION CATEGORY   OVERVOLTAGE CATEGORY II   Equipment of OVERVOLTAGE CATEGORY Il is energy consuming equipment to be  supplied from the fixed installation    Note     Examples include household  office  and laboratory appliances     OVERVOLTAGE CATEGORY III   Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations    Note     Examples include switches      the fixed installation and some equipment for  industrial use with permanent connection to the fixed instal
6. as the reference value  The display will now show readings  relative to the stored reference value  That is  display   reading   stored value  Press the  A button momentarily to activate and to exit relative zero mode     Auto ranging   Where there is more than one measuring range under a selected meter function  the  LCD annunciator          turns on  The meter will automatically switch to the best resolution  range when making measurements  No manual ranging selection is required     Auto Power Off  APO    When the meter is on  the Auto Power Off  APO  feature will switch the meter into a sleep  mode automatically to extend battery life after approximately 30 minutes of the last front  panel activity  To wake up the meter from APO  press the buttons momentarily or set the  Slide switch to the OFF position and then slide back on again  Always set the slide switch  to the OFF position manually when the meter is not in use     5  MAINTENANCE       WARNING  To avoid electrical shock  disconnect the meter from any circuit  remove the test leads  from the input jacks and turn OFF the meter before opening the case  Do not operate  with open case     11  Trouble Shooting  If the instrument fails to operate  check batteries and test leads etc   and replace as  necessary  Double check operating procedure as described in this user s manual     If the instrument voltage resistance input terminal has been subjected to high voltage  transient  caused by lightning or switching surge to th
7. e function  Relative zero  A mode can be used to zero out the parasitic capacitance of the leads and the internal  protection circuitry of the meter when measuring low capacitance in the order of Pico  Farad  pF         CAUTION  Discharge capacitors before making any measurement  Large value capacitors should  be discharged through an appropriate resistance load        ACA Current clamp on function  Inputs are made through the jaws clamps for non invasive ACA current measurements        CAUTION   Press the jaw trigger and clamp the jaws around only one single conductor of a circuit for  load current measurement  Make sure the jaws are completely closed  or else it will  introduce measurement errors  Enclosing more than one conductor of a circuit will result  in differential current  like identifying leakage current  measurement     Strong Electro magnetic field environments such as high current transformers  motors  and conductors may affect measurement accuracy     10  HOLD  The hold feature freezes the display for later viewing  Press the HOLD button  momentarily to activate or exit this feature     MAX   The max feature compares and displays the measured maximum value as fast as 30ms  with auto ranging capability  Press the MAX button for 1 second or more to activate or  exit the max feature in the following functions  DCV  ACV  amp  ACA    Relative zero A mode   Relative zero A mode allows the user to offset the meter consecutive measurements  with the displaying reading 
8. e system  by accident or abnormal  conditions of operation  the series fusible resistors will be blown off  become high  impedance  like fuses to protect the user and the instrument  Most measuring functions  through this terminal will then be open circuit  The series fusible resistors and the spark  gaps should then be replaced by qualified technician  Refer to the LIMITED WARRANTY  section for obtaining warranty or repairing service     Cleaning and Storage   Periodically wipe the case with a damp cloth and mild detergent  do not use abrasives or  solvents  If the meter is not to be used for periods of longer than 60 days  remove the  batteries and store them separately     Battery replacement  The meters use standard 3V alkaline button battery  ANSI NEDA 5004LC  IEC CR2032    In models ACD 10 PRO  amp  ACD 10 TRMS PRO  one battery are used     Loosen the two screws from the case bottom and remove the bottom case  Slide the  battery out the side of the holder and replace with a new battery  observe polarity    Replace the bottom case  Re fasten the screws     6  Specifications   General Specifications   Display   3 3 4 digits 4000 counts LCD display s    Update Rate   3 per second nominal   Polarity   Automatic   Low Battery Indication  Below approx  2 4V   Operating Temperature   0  C to 40  C   Relative Humidity   Maximum relative humidity 80  for temperature up to 31  C  decreasing linearly to 50  relative humidity at 40  C   Altitude   Operating below 2000m   Storage Te
9. eads from the test points before changing meter functions     INTERNATIONAL ELECTRICAL SYMBOLS    Caution   Refer to the explanation in this Manual  Caution   Risk of electric shock   Earth  Ground    Double Insulation or Reinforced insulation   Fuse   AC  Alternating Current   DC  Direct Current            otep    2  CENELEC Directives  The instruments conform to CENELEC Low voltage directive 73 23 EEC and  Electromagnetic compatibility directive 89 336 EEC     3  PRODUCT DESCRIPTION    4    This user s manual uses only representative model s  for illustrations  Please refer  specification details for function availability to each model     AX                    SELECT            1  Transformer Jaw Clamp for AC  current magnetic field pick up    2  Hand Finger Barrier to indicate the  limits of safe access of the meter  during measurement    3  Push buttons for special functions  amp   features    4  Push buttons for special functions  amp   features on Slide switch Selector  functions    5  Input Jack for all functions EXCEPT  non invasive ACA current function    6  Common  Ground reference  Input  Jack for all functions EXCEPT  non invasive ACA current function    7  Slide switch Selector to turn the  display power ON OFF and Select a  function    8  3 3 4 digits 4000 counts LCD display    9  Jaw trigger for opening the  transformer clamp jaw    4  OPERATION                  JA AMPROBE                        SELECT                          JE    DC Voltage  AC Voltage  Hz 
10. lation     OVERVOLTAGE CATEGORY IV   Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation   Note     Examples include electricity meters and primary over current protection  equipment     2  TERMS IN THIS MANUAL     WARNING identifies conditions and actions that could result in serious injury or  even death to the user      CAUTION identifies conditions and actions that could cause damage or malfunction  in the instrument        WARNING  To reduce the risk of fire or electric shock  do not expose this product to rain or moisture   The meter is intended only for indoor use     To avoid electrical shock hazard  observe the proper safety precautions when working  with voltages above 60 VDC or 30 VAC RMS  These voltage levels pose a potential  shock hazard to the user     Inspect test leads  connectors  and probes for damaged insulation or exposed metal  before using the instrument  If any defects are found  replace them immediately     Do not touch test lead tips or the circuit being tested while power 1  applied to the circuit  being measured  To avoid accidental short circuit of bare  uninsulated  hazardous live  conductors or busbars  switch them off before insertion and removal of the current clamp  jaws  Contact with the conductor could result in electric shock  Keep your hands fingers  behind the hand finger barriers that indicate the limits of safe access of the meter and the  test leads during measurement        CAUTION  Disconnect the test l
11. mperature    20  C to 60  C   lt  80  R H   with battery removed    Temperature Coefficient   nominal 0 15 x  specified accuracy    C   0  C   18  C or 28  C     40  C   or otherwise specified    12  Sensing   Average sensing for ACD 10 PRO  True RMS for ACD 10TRMS PRO  Safety   Meets IEC61010 2 032  1994   EN61010 2 032  1995   UL3111 2 032  1999   For ACD 10 PRO TRMS PRO  Category II 600 Volts AC  amp  DC  and Category    300  Volts AC  amp  DC  Transient protection   6 5kV  1 2 50us surge  for all models  Pollution degree   2  E M C   Meets EN61326  1997  1998 A1   EN61000 4 2  1995   and EN61000 4 3   1996   In an RF field of 3V m   Capacitance function is not specified  Other function ranges  Total Accuracy   Specified Accuracy   45 digits   Performance above 3V m is not specified  Overload Protections    ACA Clamp on jaws   AC 400A RMS continuous           amp     COM    terminals  all functions    600VDC VAC RMS  Power Supply  3V alkaline button battery  ANSI NEDA 5004LC  IEC CR2032   One  battery for ACD 10 PRO  amp  ACD 10 TRMS PRO   Power Consumption   2 5 mA typical  APO Timing   Idle for 30 minutes  APO Consumption  0 8uA typical on all functions except on ACD 10 TRMS PRO  Amps and Volts where it is 25uA  Dimension   L 7 8    X W 2 48    X H 1 25     Weight   0 412 Lb approx   Jaw opening  amp  Conductor diameter   1 02    max  Accessories   Test leads  pair   battery installed  user s manual   amp  soft carrying pouch    Electrical Specifications  Accuracy is    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Mac OS X Server File Services Administration  Beko D1 5102 B Washer User Manual  Atdec TH-3070-CTL flat panel ceiling mount  N - Achatplus    cedoC-Tech.fr  INSTRUCTIVO DE INSTALACION Y MANUAL DEL PROPIETARIO  こちらをクリック※PDFファイルが開きます。  E44286_Ultrasonic Cleaner_CH_IM - GT  Sony CDX-FW700 Operating Instructions    Copyright © All rights reserved. 