Home
7400-5708 SHoW DMX Vero Net User Manual
Contents
1. 450 11 4mm When cable is used strip outer jacket 6 0 150mm The mains connection is a 3 pos plug socket type terminal block which may be disconnected for ease of assembly Strip insulation from individual conductors 25 7 mm and terminate in the provided screw terminal socket see illustration above Mains terminations are ash shown and are marked on the unit DMX512 Wire Termination The SHoW DMX Vero Net Transceiver is provided with a PCBA mount terminal block for DMX connection see illustration above DMX Input Output connections are as shown and are marked on the unit Ethernet Cable entry The unit is provided with an RJ45 Ethernet Jack for Ethernet connection Install the Ethernet cable using the entry provided An RJ45 Ethernet Plug must be installed on the Ethernet cable after the cable is pulled into the box using the standard TIA EIA T568B Page 13 of 29 pin out Installing the Cover The 7400 5707 SHoW DMX Vero Net Transceiver has a two part cover with the outer plastic cover connected to the inner metal cover with a hinge Install the metal inner cover using the eight provided 6 32 x 375 SS Truss Head Machine Screws Hand install these screws until the screw threads are fully engaged with the mating PEM Nut then tighten to 4 inch pounds The outer cover is then closed and secured with the provided 8 18 x 500 SS Thread Forming Torx Button Head Security Screw installed in the provided hole on the left si
2. EEC Date of Issue August 15 2011 Year CE Marking First Affixed 2011 is Ed Lauren E Dunn Head of Engineering US HEADQUARTERS LONDON OFFICE 475 BARELL AVENUE UNIT 1 3 WYVERN ESTATE BEVERLEY WAY CARLGTADT NEW JERSEY 07072 NEW MALDEN SURREY KTA ait TEL 800 230 9497 201 549 1160 TEL 44 0 20 8949 5051 FAX 201 549 1161 www citytheatrical com FAX 44 0 20 7183 6061 Page 7 of 29 System Compliance Information h The 7400 5708 SHoW DMX Vero Net Transceiver is ETL Listed Conforms to UL 508A S rest Intertek The 7400 5708 SHoW DMX Vero Net Transceiver is CE Certified C C Standards Applied EN 55203 1 2009 Environments E4 and E5 EN 55203 2 2009 Environments E1 E2 E3 E4 EN 301 489 1 V1 8 1 EN 301 489 3 V1 4 1 EN 60950 1 2006 A1 2010 FCC Rules Part 15 Subpart B Sections 15 107 and 15 109 Products Conform to CE Marking Directive 93 68 EEC All SHoW DMX Neo models are RoHS compliant Safety Notices Ratings and Power Requirements Please read this entire manual before using your new equipment Please keep the manual in a safe place so you can refer to it in the future as required The SHoW DMX Neo System is intended for use only by qualified professionals Connection installation and hanging of this equipment must be performed in accordance with all pertinent local regional and national safety codes and regulations The 7400 5708 SHoW DMX Vero Net Transceiver is intended for indoor or outdoo
3. broadcast power to match the requirements of the application Limited Burst DMX Output Limited Burst mode reduces the number of DMX channels and the amount of radio energy that is broadcast by the Transmitter If you don t need all 512 DMX values and you need to control the radio energy in your system as much as possible then you can use Limited Burst to target only the DMX channels you need and reduce your radio footprint even further In Neo Limited Burst mode the user may select a contiguous group of 51 slots or more DMX slots in multiples of 52 slots 51 52 51 104 etc Limited Burst slot counts include 51 103 155 207 259 311 363 415 and 467 These may be assigned to any starting address that will not exceed the total 512 slot count when added to the remaining slots in the selected Burst size e g with 467 slots the highest allowed starting address is 46 as 46 466 512 In Classic Limited Burst Mode burst options begin with 30 DMX channels and increase in increments of 32 so the options are 30 62 94 126 etc to 478 RDM Operation RDM stands for Remote Device Management RDM is a lighting control protocol enhancement to DMX512 specified by PLASA formerly ESTA the official name is ANSVESTA E1 20 Entertainment Technology Remote Device Management over USITT DMX512 Using RDM you can select one of the 68 available Neo SHoW IDs adjust the broadcast power configure for limited burst transmission edit the RDM
4. 2dBi Nearson S131AH 2450 Omni whip SMA plug reverse polarity 2dBi t Omni whip SMA plug reverse polarity Neamon DGloeN EAS outdoor use via provided Antenna Cable 5dBi Tekfun F40 N Omni whip Male N 4 5dBi outdoor use WCP2400 R MMCxX jack on 4 coax R Centurion MMCX4 Omni whip pigtail 2 5dBi Page 4 of 29 For installations governed by FCC and or IC rules any of the approved antennas listed above may be used with the SHoW DMX Vero Transceiver please note the special installation requirements for use with the CTI 5636 14 dBi Yagi Antenna Please note that some of the antennas listed are intended for indoor use only For use in locations governed by CE rules some antenna restrictions apply Antennas from the 5792 CE Approved Antennas meet all requirements Contact City Theatrical for details ETSI power settings for all 5792 SHoW DMX Neo Radio module equipped products including the SHoW DMX Vero Transceiver are based on use with the CTI 5630 5 dBi Omni Antenna ETSI power and range will vary with the antenna used Contact your dealer or City Theatrical for more information CE Mark Conformity City Theatrical Inc declares that this product conforms to the specifications listed in this manual following the provisions of the European R amp TTE directive 1999 5 EC CE Mark Conformity City Theatrical Inc declares that this product conforms to the specifications listed in this manual following the provisio
5. 7 11 51 Classic 3 Limited High Wi Fi 7 11 52 Classic 4 Limited High Wi Fi 7 11 53 Classic 5 Limited High Wi Fi 7 11 54 Classic 6 Limited High Wi Fi 7 11 55 Classic 7 Limited High Wi Fi 7 11 56 Classic 8 Limited High Wi Fi 7 11 57 Classic 9 Limited High Wi Fi 7 11 58 Classic 10 Limited High Wi Fi 7 11 59 Classic 11 Limited High Wi Fi 7 11 60 Classic 12 Limited High Wi Fi 7 11 61 Classic 13 Limited High Wi Fi 7 11 62 Classic 14 Limited High Wi Fi 7 11 63 Classic 15 Limited High Wi Fi 7 11 64 Classic 16 Limited High Wi Fi 7 11 Neo Mode Operation In Neo Mode the SHoW DMX Vero Net Transceiver uses a new broadcast format that reduces latency to 7mS and provides further resistance to interference susceptibility or creation Neo Mode supports Adjustable Broadcast Power Limited Bandwidth Limited Burst and provides 64 new SHoW IDs providing 16 hopping patterns in each Bandwidth setting Neo SHoW ID Tables SHoW ID Mode Hopping Pattern Bandwidth 101 Neo 1 Full 102 Neo 2 Full 103 Neo 3 Full 104 Neo 4 Full 105 Neo 5 Full 106 Neo 6 Full Page 17 of 29 107 Neo 7 Full 108 Neo 8 Full 109 Neo 9 Full 110 Neo 10 Full 111 Neo 11 Full 112 Neo 12 Full 113 Neo 13 Full 114 Neo 14 Full 115 Neo 15 Full 116 Neo 16 Full SHoW ID Mode Hopping Pattern Ban
6. CITY THEATRICAL NEW YORK LONDON The 7400 5708 SHoW DMX Vero Net Transceiver User s Manual Rev4 2012 City Theatrical Inc SHoW DMX Vero Net Transceivers are covered by U S Patent 7 432 803 and other patents pending Radio Compliance Information Antennas 5792 SHoW DMX Neo Radio CE Declaration of Conformity System Compliance Information Safety Notices Ratings and Power Requirements Introduction Setting up the 7400 5708 SHoW DMX Vero Net Transceive Installation Warning Important use note Grounding Mounting Bracke Surface Mounting Mounting Orientation Pipe Mounting Cable or Conduit Entry Mains Wire Installation and Termination DMX512 Wire Terminatio Ethernet Cable entr Installing the Cover The 7400 5708 SHoW DMX Vero Net Transceiver Sett Configuration SHoW ID Classic Mode Operation Classic SHoW ID Tables Neo Mode Operation Neo SHoW ID Tables Neo Adaptive Mode Operation Neo Adaptive SHoW ID Table 7400 5708 Configuration Options Adjustable Output Power Limited Burst DMX Output RDM Operation Optional or Custom Antenna Accessories DMX512 Art Net SACN Control Input The Jese GetSet RDM Controller Operating the Jese GetSet RDM Controlle Notes on using RDM Check Change IP addres Check Change IP of Subnet Mask Check Change IP of Gateway Address Check Change sACN Universe to Wireless or Wire Check Change DMX Port Direction Check Change Adaptive Hopping Check
7. Change DHCP Mode Page 2 of 29 Radio Compliance Information 5792 SHOW DMX Neo Radio Module FCC ID VU65792 IC ID 7480A5792 FCC Part 15 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Radio Frequency Notifications FCC Notifications RF Radiation The Product is an intentional radiator of Radio Frequency RF energy In order to limit RF exposure to per
8. Device Label and enable or disable RDM traffic The SHoW DMX Vero Net Transceiver is fully enabled as an RDM proxy system so you can use RDM to manage your SHoW DMX Vero Net Transceiver system and any connected RDM responders that are downstream of the system The SHoW DMX Vero Net Transceiver supports the following RDM PIDs ym d uen rene RDM Parameter PID Comment X DISC_UNIQUE_BRANCH 0x0001 X DISC_MUTE 0x0002 X DISC UN MUTE 0x0003 Page 20 of 29 X X PROXIED_DEVICES 0x0010 X X PROXIED DEVICE COUNT 0x0011 X X SUPPORTED_PARAMETERS 0x0050 X X PARAMETER_DESCRIPTION 0x0051 X X DEVICE_INFO 0x0060 Reports Category 0x0801 X X PRODUCT_DETAIL_ID_LIST 0x0070 Repots ID 0x0604 X X DEVICE_MODEL_DESCRIPTION 0x0080 X x MANUFACTURE LABEL 0x0081 City Theatrical Inc X X x DEVICE_LABEL 0x0082 X X X FACTORY DEFAULTS 0x0090 X X SOFTWARE VERSION LABEL 0x00C0 Reports CE FCC X X DMX PERSONALITY 0x00E0 Sets Limited Burst X DMX PERSONALITY DESCRIPTION 0x00E1 X X DMX_START_ADDRESS 0x00F0 x X SENSOR_DEFINITION 0x0200 RSSI Temp X X SENSOR_VALUE 0x0201 X X X IDENTIFY_DEVICE 0x1000 X X SHOW_ID 0x8000 X X OUTPUT_POWER 0x8001 X X HOP_PATTERN 0x8002 X X BANDWIDTH 0x8003 X x x RDM_TRAFFIC_ENABLE 0x800A X X IP_ADDRESS_IN_HEX 0x800C Instructions Page 26 X X IP_SUBNET_MASK_IN_HEX 0x800D Instruction
9. Textbox and clicking the lower right facing green arrow in Tools Page 29 of 29
10. d point to point one server and one client configuration When the model 5792 is configured for point to multipoint one server and multiple clients configuration client s talk to server only one at a time client s can use any of the approved antennas listed below and the server can use any of the approved antennas listed below with the exception of the 14dBi antenna 5792 FCC IC Approved Antennas Manufacturer Model Type Connector Gain Nearson S151AH 2450S Omni whip SMA plug reverse polarity 5dBi Nearson S141AH 2450 Omni whip SMA plug reverse polarity 2dBi Nearson S131AH 2450 Omni whip SMA plug reverse polarity 2dBi Omni whip ergy T SMA plug reverse polarity via Nearson DG102N 2 4 5 25 an provided Antenna Cable 5dBi Omni whip Tekfun F40 N outdoor Male N 4 5dBi use i WCP2400 m 2 T Centurion MMCX4 Omni whip MMCX jack on 4 coax pigtail 2 5dBi Panel SMA plug reverse polarity via Maxrad MP24008XFPT outdoor Pus poarty via gapi use provided Antenna Cable Yagi SMA plug reverse polarity via Maxrad MYP24010PT outdoor we po arty via 10dBi usd provided Antenna Cable Yagi SMA plug reverse polarity via Maxrad MYP24014PT outdoor i 14dBi use provided Antenna Cable 5792 CE Approved Antennas Manufacturer Model Type Connector Gain Nearson S151AH 2450S Omni whip SMA plug reverse polarity 5dBi Nearson S141AH 2450 Omni whip SMA plug reverse polarity
11. de of the cover assembly The 7400 5708 SHoW DMX Vero Net Transceiver Settings System Settings ns Recet Default RT T DMX Term Hundreds Tens Ones SHow ID Configuration You can configure the Vero Net Transceiver s basic operating settings using the System Settings switches shown in the detail above Configuration switches P5 DMX Term DMX512 termination On or Off Turn On for end of line DMX512 connection P4 Rx Tx Receiver Rx On or Transmitter Tx Off Selects Receiver or Transmitter operation P3 Reset On or Off Switch On to Reset P2 Bootloader On or Off Sets the unit to Bootloader mode to upload and install Host and radio firmware upgrades from a connected USB Memory device Page 14 of 29 P1 Default On or Off To restore the system to factory default settings 1 Set P1 Default to On 2 Wait for PCBA LED to blink rapidly 3 Switch P1 to Off SHoW ID Like the original SHoW DMX Classic system the SHoW DMX Neo system uses SHoW IDs as a quick way to set RF configuration options Each SHoW ID represents a combination of one of 16 hopping patterns and one of four bandwidth settings The Transmitter and Receiver SHoW IDs must match for the units to communicate The SHoW DMX Vero Net Transceiver is preset at the factory with SHoW ID 201 for Adaptive Spread Spectrum Frequency Hopping and Neo Low Latency broadcast mode SHoW ID may be set manually using th
12. dwidth 117 Neo 1 Limited Low Wi Fi 1 6 118 Neo 2 Limited Low Wi Fi 1 6 119 Neo 3 Limited Low Wi Fi 1 6 120 Neo 4 Limited Low Wi Fi 1 6 121 Neo 5 Limited Low Wi Fi 1 6 122 Neo 6 Limited Low Wi Fi 1 6 123 Neo 7 Limited Low Wi Fi 1 6 124 Neo 8 Limited Low Wi Fi 1 6 125 Neo 9 Limited Low Wi Fi 1 6 126 Neo 10 Limited Low Wi Fi 1 6 127 Neo 11 Limited Low Wi Fi 1 6 128 Neo 12 Limited Low Wi Fi 1 6 129 Neo 13 Limited Low Wi Fi 1 6 130 Neo 14 Limited Low Wi Fi 1 6 131 Neo 15 Limited Low Wi Fi 1 6 132 Neo 16 Limited Low Wi Fi 1 6 SHoW ID Mode Hopping Pattern Bandwidth 133 Neo 1 Limited Mid Wi Fi 5 9 134 Neo 2 Limited Mid Wi Fi 5 9 135 Neo 3 Limited Mid Wi Fi 5 9 136 Neo 4 Limited Mid Wi Fi 5 9 137 Neo 5 Limited Mid Wi Fi 5 9 138 Neo 6 Limited Mid Wi Fi 5 9 139 Neo 7 Limited Mid Wi Fi 5 9 140 Neo 8 Limited Mid Wi Fi 5 9 Page 18 of 29 141 Neo 9 Limited Mid Wi Fi 5 9 142 Neo 10 Limited Mid Wi Fi 5 9 143 Neo 11 Limited Mid Wi Fi 5 9 144 Neo 12 Limited Mid Wi Fi 5 9 145 Neo 13 Limited Mid Wi Fi 5 9 146 Neo 14 Limited Mid Wi Fi 5 9 147 Neo 15 Limited Mid Wi Fi 5 9 148 Neo 16 Limited Mid Wi Fi 5 9 SHoW ID Mode Hopping Pattern Bandwidth 149 Neo 1 Limited High Wi Fi 7 11 150 Neo 2 Limited High Wi Fi 7 11 151 Neo 3 Limited High Wi Fi 7 11 152 Neo 4 Limited High Wi Fi 7 11 153 Neo 5 Limited H
13. e SHoW ID BCDs or using RDM Whichever method is used last takes precedence To set the SHoW ID manually simply set the SHoW ID BCD Switches to the desired SHoW ID In order to use RDM you will also need an RDM controller or a lighting control console with a built in RDM controller Your new SHoW DMX Vero Net Transceiver includes CTI s version of the Jese GetSet RDM Controller see below for details Classic Mode Operation In Classic Mode the SHoW DMX Vero Net Transceiver uses the original SHoW DMX Classic broadcast format and will communicate with Classic SHoW DMX devices such as 5600 01 Transmitter 5610 11 Receiver etc You can use this mode if you want to combine SHoW DMX Vero Net and Classic equipment in the same system Classic Mode supports Adjustable Broadcast Power Limited Bandwidth Limited Burst and uses 64 original SHoW IDs providing 16 hopping patterns in each Bandwidth setting Classic SHoW ID Tables SHOW Mode popping Bandwidth 1 Classic 1 Full 2 Classic 2 Full 3 Classic 3 Full 4 Classic 4 Full 5 Classic 5 Full 6 Classic 6 Full T Classic 7 Full 8 Classic 8 Full 9 Classic 9 Full Page 15 of 29 10 Classic 10 Full 11 Classic 11 Full 12 Classic 12 Full 13 Classic 13 Full 14 Classic 14 Full 15 Classic 15 Full 16 Classic 16 Full SHoW Hopp
14. e look for and double click on 8F00 SACN Univ The Vero Net sACN Universe Command Window Getting Data 2 The above command window will pop up 3 In this window you will have to supply the specific endpoint in the Get Command Hex textbox in Hex Endpoint 00 01 is the wireless endpoint and endpoint 00 02 is the wired sACN endpoint 4 Pressing the top left facing green arrow in tools will give you the hex equivalent of the universe in which the wired wireless endpoint is designated to Page 27 of 29 Handler for PID 8F00 SACN Univ 1 Wireless 2 Wired Get Command Hex o0 01 Set Command Hex loo 01 00 05 In coming Hex deta Do 01 00 05 01 When enabled SET commands will be broadcastto the PLASA Manufacturer ID The Vero Net sACN Universe Command Window Changing Data 5 Setting the Universe will require you to input the four digit endpoint followed by the four digits Universe you wish to use in Hex 6 In this example we have set the Universe for the Wireless endpoint to 00 05 7 Thelast two numbers in the Hex data box 01 cannot be changed Check Change DMX Wired Port Direction 1 In The Vero Net Jese GetSet device Page look for and double click on 8F01 DMX Port Direction E3 D Handler for PID 8F01 QE DMX Port Direction 1 In 2 Out Tools Get Command Hex foo 01 Set Command Hex In coming Hex date bo o1 02 When enabled SET commands will be broadcast
15. f 29 4354000013 D2 The Jese GetSet Initial User Interface with discovered Vero Net 4 Double click on the Vero Net line in the GetSet UI window to navigate into it and double click on a particular RDM function to access that function Tod o o muo 7 REC RTE City Theatrical Inc Required Parameter 7 Show SHoW DMX Neo Transceiver CE Supported Parameter Software Version Manufacturer Parameter 2 1 6 ESTA Reserved Parameter DE Las PO Pacreer z Pod dace evs Lal OED MN PE SOU SUE DMX PERECIAITY DESCRIPTION MUT DRAC OTANT ADDRESS mom SENSOR DERNITON Sow SENSOR VALLE Sus ONU 8001 Output Power ime Hop Patan SAND Ed ul Low Md Hi 8004 RDM Trafic 1 On EUR Low Latency 1 On SU Ohren iO POKED DEVICES ENHANDED HUD Aspe apps CULTA 3 The Vero Net Jese GetSet Device Page Page 24 of 29 Select the RDM Traffic PID 800A and enable it to turn on RDM traffic Manufacturer Specific Command B Handler for PID 800A RDM Traffic 1 On Out going Hex date of In coming Hex data o o p A When enabled SET commands will be broadcast to the ESTA Manufacturer ID The Vero Net RDM Traffic Command Window 5 Now return to the initial User Interface window and repeat Discovery to discover any Receivers in range of the Vero Net 6 Double Click on each of the Receivers and verify each one has RDM Traffic enabled 7 Return t
16. ghest level Takes Precedence HTP arrangement The Jese GetSet RDM Controller Help Unique ID Description The Jese GetSet Initial User Interface The Jese GetSet RDM Controller is provided with each Vero Net Transceiver To get your copy download the application from the Jese website Page 22 of 29 Go to the Jese website http www jese co uk support PON Nog 8 Support Page James Embedded Systems Engineering Using TRI Ereestyier The Jese GetSet Website Support Page Enter your Vero Net s Serial Number and Check ID located on the label on your Vero Net and click Search This will open a link to download the application Download the application and install it Connect the computer you re using to the Vero Net via its RJ45 Ethernet connectors Start the GetSet application Enter the connection menu Select Network as the connection type and enter the Vero Net s IP Address Default IP is 192 168 0 2 The Jese GetSet RDM controller is now ready to use Operating the Jese GetSet RDM Controller for detailed instructions on using Jese GetSet download the Tri Pro User quide from the Jese website as shown above 1 2 3 Plug your Vero Net and launch GetSet per above Confirm GetSet is connected to the Vero Net click the Connect icon Click The Discover Icon to discover connected devices Even if RDM is disabled in your Vero Net GetSet will discover the Vero Net Page 23 o
17. htning Product Installation and Configuration Guide City Theatrical Inc 2011 Q52 Regulatory information Radio Frequency Notifications Belgique Dans le cas d une utilisation priv e l ext rieur d un b timent au dessus d un espace public aucun enregistrement n est n cessaire pour une distance de moins de 300m Pour une distance sup rieure 300m un enregistrement aupr s de l IBPT est requise Pour une utilisation publique l ext rieur de b timents une licence de l IBPT est requise Pour les enregistrements et licences veuillez contacter l IBPT France 2 4 GHz Bande les canaux 10 11 12 13 2457 2462 2467 et 2472 MHz respectivement sont compl tement libres d utilisation en France en utilisation int rieur Pour ce Page 5 of 29 qui est des autres canaux ils peuvent tre soumis autorisation selon le d partment L utilisation en ext rieur est soumis autorisation pr alable et tr s restreint Vous pouvez contacter l Autorit de R gulation des T l communications http www art telecom fr pour de plus amples renseignements Page 6 of 29 5792 SHoW DMX Neo Radio CE Declaration of Conformity CITY THEATRICAL NEW YORK LONDON CC EC Certificate of Conformity Products covered by this Certificate SHoW DMX Neo 5792 Radio Module Standards Applied EN 301 489 1 V1 8 1 2008 04 EN 301 489 17 V2 1 1 2009 05 ETSI EN 300 328 v1 7 1 2006 10 Product Conforms to CE Marking Directive 93 68
18. igh Wi Fi 7 11 154 Neo 6 Limited High Wi Fi 7 11 155 Neo 7 Limited High Wi Fi 7 11 156 Neo 8 Limited High Wi Fi 7 11 157 Neo 9 Limited High Wi Fi 7 11 158 Neo 10 Limited High Wi Fi 7 11 159 Neo 11 Limited High Wi Fi 7 11 160 Neo 12 Limited High Wi Fi 7 11 161 Neo 13 Limited High Wi Fi 7 11 162 Neo 14 Limited High Wi Fi 7 11 163 Neo 15 Limited High Wi Fi 7 11 164 Neo 16 Limited High Wi Fi 7 11 Neo Adaptive Mode Operation The SHoW DMX Vero Net Transceiver can be configured to operate in the new Neo Adaptive AFHSS Mode Neo Adaptive Mode uses an Adaptive Spread Spectrum Frequency Hopping broadcast format in which the system detects interference and adapis its frequency hopping channel set automatically to avoid it Neo Adaptive Mode supports Adjustable Broadcast Power and provides 4 new Adaptive Mode SHoW IDs Latency is also reduced to 7mS max in Adaptive Mode Neo Adaptive SHoW ID Table SHoW ID Mode Hopping Pattern Bandwidth 201 Neo Adaptive Adaptive Full 202 Neo Adaptive Adaptive Full Page 19 of 29 203 Neo Adaptive Adaptive Full 204 Neo Adaptive Adaptive Full 7400 5708 Configuration Options You can set SHoW ID either with the BCD switches as described or via RDM All other configurations settings must be set via RDM Adjustable Output Power The broadcast power of the SHoW DMX Vero Net Transceiver is adjustable to allow the user to calibrate the system s
19. ing ID Mode Pattern Bandwidth 17 Classic 1 Limited Low Wi Fi 1 6 18 Classic 2 Limited Low Wi Fi 1 6 19 Classic 3 Limited Low Wi Fi 1 6 20 Classic 4 Limited Low Wi Fi 1 6 21 Classic 5 Limited Low Wi Fi 1 6 22 Classic 6 Limited Low Wi Fi 1 6 23 Classic 7 Limited Low Wi Fi 1 6 24 Classic 8 Limited Low Wi Fi 1 6 25 Classic 9 Limited Low Wi Fi 1 6 26 Classic 10 Limited Low Wi Fi 1 6 27 Classic 11 Limited Low Wi Fi 1 6 28 Classic 12 Limited Low Wi Fi 1 6 29 Classic 13 Limited Low Wi Fi 1 6 30 Classic 14 Limited Low Wi Fi 1 6 31 Classic 15 Limited Low Wi Fi 1 6 32 Classic 16 Limited Low Wi Fi 1 6 SHoW Hopping ID Mode Pattern Bandwidth 33 Classic 1 Limited Mid Wi Fi 5 9 34 Classic 2 Limited Mid Wi Fi 5 9 35 Classic 3 Limited Mid Wi Fi 5 9 36 Classic 4 Limited Mid Wi Fi 5 9 37 Classic 5 Limited Mid Wi Fi 5 9 38 Classic 6 Limited Mid Wi Fi 5 9 39 Classic 7 Limited Mid Wi Fi 5 9 40 Classic 8 Limited Mid Wi Fi 5 9 41 Classic 9 Limited Mid Wi Fi 5 9 42 Classic 10 Limited Mid Wi Fi 5 9 Page 16 of 29 43 Classic 11 Limited Mid Wi Fi 5 9 44 Classic 12 Limited Mid Wi Fi 5 9 45 Classic 13 Limited Mid Wi Fi 5 9 46 Classic 14 Limited Mid Wi Fi 5 9 47 Classic 15 Limited Mid Wi Fi 5 9 48 Classic 16 Limited Mid Wi Fi 5 9 SHoW Hopping ID Mode Pattern Bandwidth 49 Classic 1 Limited High Wi Fi 7 11 50 Classic 2 Limited High Wi Fi
20. ns of the European R amp TTE directive 1999 5 EC City Theatrical Inc vakuuttaa t ten ett dieses produkt tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sita koskevien naiden direktiivien muiden ehtojen mukainen City Theatrical Inc d clare que le produit est conforme aux conditions essentielles et aux dispositions relatives a la directive 1999 5 EC EN 301 489 1 301 489 17 General EMC requirements for Radio equipment EN 60950 Safety EN 300 328 Technical requirements for Radio equipment CAUTION This equipment is intended to be used in all EU and EFTA countries Outdoor use may be restricted to certain frequencies and or may require a license for operation Contact local Authority for procedure to follow Note ESD precautions should be used when attaching or removing the antenna Note Combinations of power levels and antennas resulting in a radiated power level of above 100 mW equivalent isotropic radiated power EIRP are considered as not compliant with the above mentioned directive and are not allowed for use within the European community and countries that have adopted the European R amp TTE directive 1999 5 EC For more details on legal combinations of power levels and antennas contact City Theatrical Inc Do not use this product near water for example in a wet basement or near a swimming pool Avoid using this product during an electrical storm There may be a remote risk of electric shock from lig
21. o the initial User Interface window and repeat Discovery to discover any Responders connected to the Receivers that you have just enabled Each Responder discovered will be available by double clicking on it in the initial User Interface window which will produce a similar Device page with a list of available PIDs Notes on using RDM Remember that when RDM is enabled the system uses 25 of its available DMX bandwidth for RDM so DMX fidelity and refresh rate are reduced For best DMX fidelity disable RDM traffic from the Receivers back to the Transmitting Vero Net when you are not using RDM You can use RDM to change SHoW IDs in connected devices Remember that once you have changed the SHoW ID in a connected Receiver you will lose communication with that Receiver until you change your Transmitter to the matching SHoW ID Page 25 of 29 Check Change IP address 1 Once GetSet is connected to the Vero Net click on the device discovered 2 A new window will pop up and under Supported Parameters find 800C IP Address in Hex and double click it Handler for PID 800C IP Address in Hex Get Command Hex Set Command Hex In coming Hex data co ae 00 02 When enabled SET commands will be broadcastto the PLASA Manufacturer ID 4 gt The Vero Net DMX Port Direction Command Window 3 Clicking the top green arrow pointing to the Left will return the IP address your Vero Net is cu
22. position with the cable entries on the bottom and antenna connector on the top as shown in the drawing above Pipe Mounting The SHoW DMX Vero can also be mounted on a pipe Attach the Mounting Bracket Base to a pipe using a stainless steel hose clamp as shown C Slide the mating Mounting Bracket attached to the Unit into the Mounting Bracket Base until the locking clip engages and install the retaining screw Cable or Conduit Entry The unit enclosure is provided with 72 NPT entry holes fitted with liquid tight cable grips for use with outdoor use cables by installer for power DMX and Ethernet connection The recommended torque for these cable grips is as follows Locking Nut 40 45 inch pounds Sealing Nut 50 55 inch pounds Page 12 of 29 If outdoor use conduit is used instead it is recommended that the conduit be sealed after installation to prevent moisture entry including free air exchange in order to minimize the chance of condensation buildup Antenna Connector N RF Signal Strength LEDs Mains Input Terminal USB Port Mains Wiring Entry NS DMX Port Terminal Scu Earth Ground Jumper DMX Wiring Entry Ethernet Wiring Entry Ethernet Jack Mains Wire Installation and Termination Install the mains cable or conduit in the entry provided as shown in the drawing below A liquid tight cable grip is provided for use with suitable outdoor rated cable with diameter range of 170 4 3mm
23. r system must be within sight of each other Warning To avoid electric shock do not energize any circuits before all internal and external electrical and mechanical clearances are checked to assure that all assembled equipment functions safely and properly Important use notes This unit must be used with voltages below 600V This unit must be installed in accordance with the National Electrical Code ANSI NFPA 70 where the ambient temperature does not exceed 40 C 104 F maximum Grounding This enclosure has been provided with a ground bond jumper for ground connection between the back box and the cover This jumper must be installed as shown in the drawing above using the provided hardware Mounting Bracket The provided mounting Bracket Base can be mounted on a surface or a vertical pipe For surface mounting the Bracket base is provided with slots and holes suitable for 10 M4 screws or similar fasteners Surface Mounting Mount the Mounting Bracket Base in the desired location using four x 10 M4 screws by others as above Slide the mating Mounting Bracket attached to the Unit into the Mounting Bracket Base until the locking clip engages and install the provided 8 18 x 500 SS Thread Forming Torx Button Head Security Screw in the hole on the left side of the Bracket assembly Page 11 of 29 Mounting Orientation The 7400 5708 SHoW DMX Vero Net Transceiver must be mounted exclusively in an upright mounting
24. r use The unit enclosure is rated NEMA 4 IP66 Rated operating voltage 100 240VAC 50 60 Hz 1A max This device must be provided with a 20A branch circuit breaker or equivalent suitable external disconnecting device Maximum operating temperature 0 C 40 C Warning The 7400 5708 SHoW DMX Vero Net Transceiver must be mounted exclusively in an upright mounting position with the cable entries on the bottom and antenna connector on the top as shown in the Installation guide See the Installation Guide in this document for details Page 8 of 29 RF Exposure The antenna s used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter Page 9 of 29 Introduction Thank you for using City Theatrical s 7400 5708 SHoW DMX Vero Net Transceiver The 7400 5708 SHoW DMX Vero Net Transceiver features include NEMA 4 IP 66 rated enclosure Transceiver fully configurable for Transmit or Receive One model FCC IC and CE Certified New DMX synchronized hopping structure with increased interference immunity reduced interference generation and extremely low latency Selectable true Adaptive Spread Spectrum Frequency Hopping ASSFH in Neo Modes Ethernet Port via RJ 45 Jack supports multiple Ethernet show control protocols including sACN Art Net and KiNet USB Port for easy future firmware updates Th
25. ree Operating Modes Neo Mode Fully configurable using RDM commands from an external RDM controller or the host Replace missing packets with previously received data if any are lost 7mS typical latency Selectable Output power 1 72mW ETSI Selectable Bandwidth Selectable Burst Length when used with full frame sources Allows for shortened frame data less than 512 bytes from source Enhanced RDM Proxy performance Neo Adaptive Mode Fully configurable using RDM commands from an external RDM controller or the host Replace missing packets with previously received data if any are lost 7mS typical latency Adaptive Hopping Selectable Output power 1 72mW ETSI Allows for shortened frame data less than 512 bytes from source SHoW DMX Classic Mode Communicates with original SHoW DMX equipment DMX Synchronized Hopping User selectable Full or Limited Bandwidth User selectable Full or Limited Burst User selectable Output Power 1 72mW ETSI Every effort has been made to anticipate your questions in this manual but if you have any questions that are not answered here or you want to discuss a special application please feel free to contact us directly at City Theatrical Page 10 of 29 Setting up the 7400 5708 SHoW DMX Vero Net Transceiver Installation Install the SHOW DMX Vero Net Transceiver in a suitable location following the instructions below When selecting a mounting location note that for best results the antennas in you
26. rrently set on in Hex Converting the number to decimal will effectively return the factory setting IP address specified in page 23 4 Changing the IP address requires you to write the new address in Hex inside of the Set Command Hex box and click the bottom green arrow pointing to the Right in Tools Numbers in Hex must be two numbers or characters with a space in between 5 After changing the IP Address the Vero Net will no longer work with the factory set IP Address 6 To reconnect in the Jese GetSet original screen click on Connection on the Top Left and click on Settings Then Under Network Address input your new set IP Address in Decimal Check Change IP of Subnet Mask 1 Changing the IPSubnet Mask follows the same steps as Changing IP address the only difference is that in step 2 you will search for 800D IP Subnet Mask in Hex and double click on this parameter Then following the steps in changing the IP Address above will allow you to change and check your IP Subnet Mask Check Change IP of Gateway Address 1 Changing the IP of the Gateway Address follows the same steps as Changing IP Address also The only difference is in Step 2 in which you will double click on Page 26 of 29 800E IP Gateway Address in Hex under Parameter Then following the above steps will let you change and check the IP of the Gateway Address Check Change sACN Universe for Wireless or Wired ports 1 Once in the The Vero Net Jese GetSet Device Pag
27. s Page 26 X X IP_GATEWAY_ADDRESS_IN_HEX 0x800E Instructions Page 26 x X DHCP_MODE 0x800F Instructions Page 29 X X LATENCY 0x8019 X X X DMX RDM INTERLEAVE RATIO 0x801B X X X PROXIED DEVICES ENHANCED 0x801C X X ADAPTIVE_ON_OFF 0x801D Instructions Page 29 X X SACN_UNIVERSE Ox8F00 Instructions Page 27 X X DMX PORT DIRECTION Ox8F01 Instructions Page 28 Page 21 of 29 In order to allow RDM traffic and discovery and control of connected Responders you must enable RDM Traffic Set RDM_TRAFFIC_ENABLE to 01 Note that DMX transmission fidelity is reduced when RDM Traffic is enabled To learn more about RDM a good place to start is the Wikipedia article on RDM lighting at http en wikipedia org wiki RDM_ lighting ETSI power settings for all 5792 SHoW DMX Neo Radio module equipped products including the SHoW DMX Vero Net Transceiver are based on use with the CTI 5630 5 dBi Omni Antenna ETSI power and range will vary with the antenna used Contact your dealer or City Theatrical for more information Optional or Custom Antenna Accessories You system may have been supplied with optional or custom antenna distribution accessories such as antennas splitters attenuators lighting arrestors or other devices Please contact City Theatrical directly for details DMX512 Art Net SACN Control Input The SHoW DMX Vero Net Transceiver will accept DMX512 Art Net or SACN control input All inputs are live and will be combined in a Hi
28. sonnel in the immediate area the Product should be located and installed such that a separation of at least 20 centimeters is maintained between the Product s antenna and personnel in the vicinity of the device Modification Warning Caution changes or modifications to this equipment not expressly approved by City Theatrical Inc could void the user s authority to operate the equipment Industry Canada Notifications This Class B digital apparatus complies with Canadian ICES 003 Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada Product Installation and Configuration Guide City Theatrical Inc 2007 5792 Approved Antenna To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that permitted for successful communication This device has been designed to operate with the antennas listed below Antennas not included in this list or having a gain greater than 5 dB are strictly prohibited for use with this device The required antenna impedance is 50 ohms Page 3 of 29 Antennas The model 5792 can be configured with any one of the approved antennas listed below for fixe
29. to the PLASA Manufacturer ID oo The Vero Net DMX Port Direction Command Window Page 28 of 29 2 To check the Port direction Type in a specific endpoint 00 01 or 00 02 in the Get Command Textbox and click the top left pointing arrow in Tools The final two digits will tell you the Port direction of the endpoint 02 Out and 01 In Changing the Port Direction can only be done to the second specific endpoint 00 02 Typing the endpoint in the Set Command textbox followed by a space and 01 or 02 will change it between in and out Check Change Adaptive Hopping 1 Once in The Vero Net Jese GetSet Device Page find and double click on the 801D Adaptive Hopping Parameter A Command window will appear Clicking the upper left facing arrow in Tools will return in Hex the Neo Adaptive mode The factory setting is 00 Off To Change the mode simply enter 00 Off or 01 On in the Set Command Hex Textbox and click the lower right facing arrow in Tools Check Change DHCP Mode 1 2 DHCP mode allows you to change your IP either to Dynamic or Static From The Vero Net Jese GetSet Device Page find and double click on the 800F DHCP Mode Parameter A Command window will appear Clicking the top left facing green arrow in Tools will give you the DHCP mode in Hex It is set to factory setting of 00 Static Changing the DHCP mode only requires placing 00 Static or 01 Dynamic in the Set Command
Download Pdf Manuals
Related Search
Related Contents
User`s Manual - Kramer Electronics 1 P Se a plaqueta do número de série do motor contiver a marca CE BAUER T 1 M - Kinobauer.de 1 SmartTVBox サービス利用規約 目 次 第 1 条(規約の適用 Philips Brilliance LCD monitor, LED backlight 19S4LCS I. Mode d`emploi Tricity Bendix TBS 613 User's Manual Copyright © All rights reserved.
Failed to retrieve file