Home
VOCAL User Guide - Gradient Lens Corporation
Contents
1. Appendix A Optional VOCAL Configuration Files VOCAL_Labels cfg VOCAL_Report cfg Appendix B SNAP Server Setup Appendix C Bosch Specific Setup Where the Files are Located Setting Up an Inspection Procedure Advanced Special File Editing VisionGauge is a registered trademark of VISIONx INC www visionxinc com Microsoft is a registered trademark and Windows is a trademark of Microsoft Corporation All other nationally and internationally recognized trademarks and trade names are hereby acknowledged VOCAL User Guide v3b doc 2 1 31 01 oreo 0O son w N m Hem Vere O 12 13 15 15 16 16 17 18 21 21 22 24 Quick Reference Instructions for Operating VOCAL To begin using the computer inspection workstation 1 Log on to Windows using your User name and Password 2 Click on the icon titled VisionGauge that is on the Desktop 3 VisionGauge will open and occupy the entire screen 4 Click on the VOCAL button on the right side of the screen 5 This will bring up a new window labeled VOCAL VOCAL Window Description The VOCAL window appears when the VOCAL button is pressed on the main VisionGuage screen This window is where the majority of your mouse clicks will be performed Below is a description of the VOCAL window s buttons and labels Contains a menu for Supervisor s All options are password protected Contains a Help menu Press for access to the drop down
2. This will not add a new part to the drop down menu but add a new feature to the VOCAL window under the specific part To scroll through these click the Next gt gt or Previous lt lt buttons within the VOCAL window To Remove Parts amp Features 1 Select the designated part and feature that you wish to remove from the VOCAL window Click Supervisor from the window header Select Remove Enter password gradient all lower case Click OK Note when you do this VOCAL removes the record from the appropriate text file s but does not delete the relevant reference images VOCAL User Guide v3b doc 15 1 31 01 Appendix A Optional VOCAL Configuration Files There are two additional configuration files which can be used to customize labels in the VOCAL window and in the reference image report These are called VOCAL _Labels cfg and VOCAL_Report cfg They are located in the main VisionGauge directory where you installed VisionGauge If these files do not exist then VOCAL uses default values for the labels The names of labels can be changed by defining one or both of these files using a text editor like NotePad which comes with MS Windows VOCAL Labels cfg The VOCAL_Labels cfg file can be created in the main VisionGauge to override the labels that VOCAL uses to refer to the text box labels in the VOCAL window and to the Flags available to assign to operator saved images If the VOCAL _Labe
3. VOCAL Video Optical Comparison and Logging User Guide VOCAL is a custom user interface developed by Gradient Lens Corporation and designed to work within the VisionGauge measurement software to provide image comparison and logging capabilities on the production floor and can easily accommodate multiple workstations and permits web browser access across a network to QC data and image files It was developed for use with borescope video inspection but can also be used with video microscopes or other video inspection equipment This User s Guide includes instructions for operating the VOCAL in a specially configured version of the VisionGauge measurement software For full documentation on the VisionGauge measurement software please refer to the Operators Manual which comes with the VisionGauge product Copyright 2000 Gradient Lens Corporation All rights reserved Gradient Lens Corporation 1 31 01 Rochester NY 14608 800 536 0790 Table of Contents Table of Contents Quick Reference Instructions Installation The VOCAL cfg Configuration File N etwork Installation Password Protection Operator Procedures Starting VOCAL Test Procedure Exiting VOCAL Supervisor Procedures Reference Images Generating N ew Reference mages In the Save FileAs Window Setting up New Parts and Features From the images previously saved To resize the image Adding Features to the Same Part To Remove Parts amp Features
4. If you are using a different file server such as a Linux based SAMBA server or a Windows NT server the procedure is basically the same The file server must be installed on the network and visible from the computer on which VisionGauge and VOCAL are installed The network administrator will have to set up two network shares which should have appropriate username group access restriction for your installation The network shares can be named anything you like since the path to the shares will be defined in the VOCAL cfg file The first network share we will call it REFS is used to hold the part name configuration file and the pairs of reference images used by VOCAL This share should be set up with access rights so that the QC Manager can read and write to the directory and Operators can only read from the directory VOCAL User Guide v3b doc 6 1 31 01 The other network share we will call it SAVES is used to hold all of the captured images and the HTML table file which stores information associated with each captured image This share should be set up with read and write access for the Supervisor and Operators If there are others in the Company that should be allowed to review the test data they should be set up in a third group that has read only access to both of the VOCAL shares Once this initial setup is complete the VOCAL software will allow for the routine maintenance of the various VOCAL files and the directory structur
5. command and position it on the screen as desired The lower left corner or upper right corner are good choices Now select Save under the Supervisor menu of the VOCAL window and in the dialog box that appears enter the name of the procedure in the top VOCAL User Guide v3b doc 23 1 31 01 box RJ0467 Multiport for example the word REFERENCE in the middle box and the number 1 in the third box Then click OK Now the LIMIT Sample images can be added Keep the reference where it is and open the first LIMIT Sample image using File Reference Open and position it next to the original reference image Now save this using Supervisor Save in the VOCAL window This will bring up the same dialog box as before with the old text filed in Leave the top box with the procedure name alone so this is added to the same inspection procedure Change the middle box to indicate whether this LIMIT Sample image represents a GOOD REWORK or SCRAP image Change the number in the lower box to 2 since this is the second step in the procedure Close the LIMIT Sample image and keep the Reference image then repeat the steps in the last paragraph until all of the LIMIT Sample images are added to the inspection procedure The new Inspection Procedure has now been defined To use it the Operator selects it from the pull down menu and clicks the Live Image button in the VOCAL window This provides them with a display of the Live Image and the Reference I
6. menu to Displays current part select different parts number or description Part No Displays current feature soa ble teria Feature of the part Displays the sequence number No Allows user to scroll for the features of the part through the different features of the same Comments part Enter text here before pressing Press for Live Video save to record comments Click to save image about a particluar image after text is completed Closes VOCAL window In the VOCAL window 1 Using the drop down menu for Part No select the part you would like to inspect The drop down menu is reached by clicking on the downward facing arrow next to the white Part No box Note This will bring up two Reference Images on the right hand side of the screen These images correspond to the selected Feature located just under the Part No box Ex If the Feature is labeled O Degree Hole the two reference images represent this feature on the part THE IMAGE ON THE TOP IS ALWAYS THE GO IMAGE THE IMAGE ON THE BOTTOM IS ALWAYS THE NO GO IMAGE 2 The Feature description also corresponds with the borescope that is required to complete the inspection of that feature Ex The Feature labeled O Degree Hole requires that the 0 borescope is used this information is located on the body of each borescope except the 82070 semi rigid 0 borescope 3 To obtain a live video signal and begin i
7. of image files then the setup is particularly easy Other file servers such as a Linux hosted SAMBA server or Windows NT file server can also be used but details will not be documented here Please refer to their own user documentation Only the highlights of the SNAP Server setup as it relates to VOCAL will be covered and you are referred to the SNAP Server User s Manual for a complete description This can be found online at lt http Awww snapserver com documentation asp gt The SNAP Server provides a web based configuration tool which can be used to set up shared directories referred to as Network Shares The same tool also allows the SNAP Server Administrator to set up Users and Groups Each Network Share or Share for short can have its access rights defined as read write or read only on a User by User basis Users can also be assigned to Groups which can be given their own access rights to the Shares For a user to gain access to files in Shares which have access rights defined they must provide a valid Username and Password By default Windows will attempt to use the login Username and Password If the user has properly logged into Windows using the assigned Username and Password then the correct access to the VOCAL directories should be transparent Begin setting up the SNAP Server by defining the Users and Groups Enter the URL for the SNAP Server in a web browser If a DNS entry for the SNAP Server has been set up on t
8. the parts are inspected and what kind of information in terms of reference images you want to provide to the operator We will refer to these two inspection methods as the Part Feature method and the Procedure method In the Part Feature method you will organize the reference images into a series of GO NOGO images which will be presented to the operator with one pair for each feature of a part VOCAL allows you to set up an unlimited number of features per part each with a pair of images If an operator will be inspecting all features on a part before moving to the next part then this may be the best method to use The Procedure method allows you to present a REFERENCE image representing a perfect part feature and then allowing the Operator to cycle through a series of Limit Sample images if they are unsure if the feature they are viewing is OK The Limit Sample images would show various defects for the feature and indicate to the operator whether the particular Limit Sample image was PASS or FAIL If an operator will be inspecting the same feature on many parts before moving on to the next part or if two reference sample images are not enough to characterize your feature then this may be the best method to use Whichever method you choose it is recommended that you set up a separate directory outside of the VisionGauage VOCAL directories to build a library of Limit Sample images for your parts The library directory can be organize
9. where the information is saved when the operator presses VOCAL s Save button Line 4 Contains the html filename for all the Operator saved text information Please note that this file will be saved in the directory pointed to in line 3 of this file Line 5 The computer s Station ID used when the operator presses VOCAL s Save button If the VOCAL directory is to be installed on a network file server then there are a few additional steps required to complete the installation Aspects having to do with Network Installation are discussed in the following section of this User s Guide Here s an example of a VOCAL cfg file in the case where all of the information is saved on the local hard drive VOCAL User Guide v3b doc 5 1 31 01 C A VOCAL VOCAL_PartNumbers txt C VOCAL_Save VOCAL SaveFile html STAO1 Here s an example of a VOCAL cfg file in the case where all of the information is saved on a Snap Server on the network Snap114095 VOCAL Refs VOCAL _PartNumbers txt Snap114095 VOCAL Save VOCAL SaveFile html STAO1 Here s an example of a VOCAL cfg file in the case where all of the information is saved on a network drive which has been mapped to I on the workstation I ecmcat Refs VOCAL_PartNumbers txt r ecmcat Saves VOCAL_SaveData html STAO1 Network Installation The details in this section apply to the use of a SNAP Server as the network file server
10. The DataKeeper software can be configured to automatically back up changed files from your system to the SNAP Server keeping a user defined number of previous versions If you are interested check the DataKeeper documentation that came with the SNAP Server Another feature of the SNAP Server that should probably be set up is its ability to email someone if it detects any errors during its operation Up to 2 email addresses can be included to receive any error messages from the SNAP Server If more than this are needed set up the 2nd e mail address to mail to an alias which can be expanded to as many people as you desire See VOCAL User Guide v3b doc 19 1 31 01 your Network Administrator for help You will need the address of your SMTP mail server to make this feature work For more detailed information on the SNAP Server please refer to the SNAP Server User Manual or online documentation at lt www snapserver com gt VOCAL User Guide v3b doc 20 1 31 01 Appendix C Bosch Specific Setup Where the Files are Located There are three directories which contain files used by VisionGauge VOCAL These are named VisionGauge Refs and Saves The program directory named VisionGauge is located on the C drive of the workstations and is located either in the Program Files directory or at the root of C depending upon how VisionGauge was installed on the workstation The program directory contains the program exe file and the VOCAL cfg file w
11. a leading back slash for example VOCAL_Refs The Comment is optional but it is important to choose the Create Network Share with no access rights options before clicking OK You will be asked if it is OK to create the Share and you should reply that it is OK You will be taken directly to the Share Access Setup screen where you can scroll through the list of defined users and groups highlight the desired ones and click the lt Add or Remove gt buttons until the list is as you desire Be sure the pull down list at the right is set to the correct access right before you Add the user or group The suggested access rights are Full Access for the Supervisor to both Shares For the Operator give Full Access to the VOCAL Save Share and Read Only to the VOCAL Refs Share The Engineer group should have Read Only access to both Shares Of course you are free to set this up with more groups or different access rights to meet your specific needs NOTE If your network is setup to use NT Domain Security then the SNAP Server can be configured to use the same Users and Groups defined on the NT Server Refer to the Security Guides found at the top of the Security screen and contact your network administrator for assistance You may also want to check out the supplied DataKeeper Snap Edition which is an excellent automated backup program if automatic backups are not already being done by your Network System Administrator
12. art No This is the name you want to appear in the drop down menu Ex One or Unit Body etc Feature This is the feature that needs to be inspected This should correlate with the borescope that is needed to complete the inspection Ex 0 Degree Hole requires a Borescope to inspect it Another way to label this is to put the borescope part number here so that users know which borescope they need to use for the inspection No This is where you want these images to appear in the sequence of reference images Ex 1 would be the first image to appear 2 the second etc Each new set of reference images for the same part should be given the next number existing number plus one 6 Give the Reference Images a Part No or Name 7 Give the Reference Images a Feature description 8 Be sure that the No box reflects the correct number where it should appear in the sequence of reference images 9 Click OK The new part and features will appear under the Part No drop down menu in the VOCAL window VOCAL User Guide v3b doc 14 1 31 01 Adding Features to the Same Part 1 Complete the section above Setting up New Parts and Features EXCEPT when the Save window appears Part No i Feature No Use the same Part No Change the Feature description to reflect the new Reference Images Change the No box to reflect the current number plus one ex 1 to a 2 Click OK
13. asic Installation The VOCAL software is automatically installed as part of the custom VisionGauge software installation Refer to installation instructions in the VisionGauge manual for full details In addition to the standard VisionGauge files a series of configuration files and additional directories are created In the main VisionGauge directory the file VOCAL cfg must exist This is the file that determines the default parameters used by the VOCAL program In addition there are several optional VOCAL configuration files which can be used to customize some of the window and report labels for your company s particular way of doing things These optional configuration fles are described in Appendix B The VOCAL cfg Configuration File The VOCAL cfg is a simple ASCII text file You can use a simple ASCII file editor such as Notepad that comes with Windows to create and edit it VOCAL cfg must contain the following 5 lines of information Line 1 Contains the path for all of the Reference image information i e this is where the Part Feature records are saved including the corresponding images Line 2 Contains the name of the text file containing the list of all Part s that exist in the Reference image data set Please note that this file will be saved in the directory pointed to in line 1 of this file Line 3 Contains the path for the Operator saved information i e this is
14. be doing this agree on a standard procedure and that the procedure is documented and followed First the Setup Manager should have a collection of images of the part feature which represent the various GOOD REWORK and SCRAP conditions that they wish to have the Operators use while inspecting the parts A convenient place for these is the I ecmcat library directory on the network with a separate sub folder for each part feature Since there are several Setup Managers it would be a good idea to create a simple text file in each of the part feature directories to document what each image is and whether it represents GOOD REWORK or SCRAP Next the Setup Manager should determine which image in the library they will use as the perfect GOOD image and which images they want to include in the inspection procedure for the other LIMIT Samples All of these images should be opened in VisionGauge using File Image Open resized and or cut out to the final size and any annotation desired should be added and they should be saved back into the library folder with new names such as REFERENCE LIMITO1 LIMITO2 etc Once the reference images are ready in the library they can be put into VisionGauge VOCAL as an inspection procedure Select the VOCAL button if the VOCAL window is not already showing and position is at the lower right of the screen Open the REFERENCE image saved in the library for the part feature use the File Reference Image Open
15. bers is defined in the VOCAL cfg file discussed earlier You may view the VOCAL cfg file to determine the name of this file that is used for your workstation Each line of the VOCAL _PartNumbers txt file must match the name of the VOCAL User Guide v3b doc 24 1 31 01 sub directory which contains the Reference Images for the Inspection Procedure The names that appear in this list are the same as the ones that are displayed in the drop down list of Parts in the VOCAL window If you no longer want a particular inspection procedure to show up in the drop down list then delete its name from the VOCAL_PartNumbers txt file Within each sub directory in REFS there is a text file that describes the inspection procedure whose name matches the directory name The directory name and this file are created automatically when you create an inspection procedure using the Supervisor Save item in the VOCAL window The only time you need to manually edit this file is if you want to make a simple change to the inspection procedure without having to delete the existing procedure and start over NOTE Adding additional LIMIT Sample images to an existing procedure should normally be done using the Supervisor Save menu item in the VOCAL window To do this set up the Reference Image and Limit Image as described above and be sure the number entered in the bottom box is one greater than the last one already defined If all you want to do is change the label display
16. d is acceptable A typical inspection procedure would consist of a picture of a GOOD feature followed by a series of LIMIT Samples which have been selected by the Setup Managers The Operators can cycle through the LIMIT Samples and determine if the feature they are currently inspecting matches one of the LIMIT Samples If is does then they use the GOOD REWORK or SCRAP label assigned to the LIMIT Sample to determine if the feature is acceptable If there is not a match the Operator can either find a Setup Manager to make a decision or Save the image along with a Comment so they can review the questionable feature with a Setup Manager later If the Setup Manager wants they can add the questionable feature image to the Library and or add it to the LIMIT Samples the Operator uses for future inspections of the feature The basic steps for saving reference images is covered in the VOCAL User s Guide in the section titled Setting up New Parts and Features From the images previously saved This section will suggest a particular method of setting up an inspection procedure based upon discussions with the Setup Managers on 1 22 1 23 2001 at the Charleston plant The way parts are currently inspected the same feature on 100 to 200 parts is inspected and then the Operator moves onto the next feature on this lot of parts The Setup Managers want to have VOCAL present a GOOD image of a part feature to the Operator along with the live video If th
17. d with a separarte sub directory for each part and or feature for which you will be saving Limit Sample images Your library of images can then be used to build your inspection procedures in VOCAL Of course VisionGauge VOCAL is a great tool to capture and annotate your library of images The operator saved images are also available to add to your Limit Sample library Just copy the appropriate operator saved image to your library directory The following sections describe the procedures for saving reference images and using VOCAL to organize them into inspection procedures These are the same whichever inspection method you choose The only difference will be the way you name the procedure and what images you add to VOCAL User Guide v3b doc 10 1 31 01 each step If you choose the Procedure method you may rename the Labels in the VOCAL window to better reflect what each text box represents See Appendix A for the details In the Procedure method the top text box in the VOCAL window is the Procedure Name and the middle text box is the Disposition When the Part Feature method is used the Top text box is the Part Number and the middle text box is the Feature name In either case the Next gt gt button takes the operator to the next step in the inspection procedure Reference Images You can use VisionGauge to load from disk and display reference images e g for image comparison Each reference image is displayed in its own wind
18. e All that is left now is for the Supervisor to define the parts which will be inspected and determine the pair of reference images that will be displayed along with the live video to the operator during their inspection This setup is covered in the section titled Setting Up Part Feature Records Here s an example of a VOCAL cfg file in the case where all of the information is saved across the network to a Snap Server Snap114095 REFS VOCAL_PartNumbers txt Snap114095 SAVE VOCAL _SaveData html STAO1 Password Protection VOCAL uses VisionGauge s built in Lock Out password protection to stop anyone not having supervisor level privileges from modifying VOCAL s reference image data set Here s how VisionGauge s Lock Out password protection works to enable the password protection use a simple ASCII file editor such as Notepad that comes with Windows to create a file called LockOut pwd in VisionGauge s Setups directory Type in the calibration password in this file and then save it to disk When this file exists VisionGauge prompts the user for the password whenever the user attempts to save change or delete a reference image data record Enter Lock Out Password Password VisionGauge s Lock Out password protection is described in detail in chapter 5 of the VisionGauge User s Guide VOCAL User Guide v3b doc 7 1 31 01 Operator Proced
19. e live part feature does not match the GOOD image then the Operators should step through a series of LIMIT Sample images to try and find a match Each VOCAL User Guide v3b doc 22 1 31 01 LIMIT Sample will be marked as GOOD REWORK or SCRAP If a match is found then the operator takes the action indicated by the LIMIT Sample If no match is found the Operator Saves the image and sets the part aside until a Setup Manager can make a decision The Operator saved image can be used by the Setup Managers as a new LIMIT Sample to add to the inspection procedure if they determine this is a new defect which may be occurring and needs special attention Selecting the inspection procedure again from the pull down menu will restart the procedure from the beginning How does the Setup Manager create a new Inspection Procedure There are several steps needed to set up a new Inspection Procedure The description here assumes that the user is already familiar with the basic operations of capturing an image saving the image adding annotation to the image opening a reference image and positioning the reference image on the screen If you do not already know how to do these things then go back and read the appropriate sections of the VOCAL Users Guide This is not the only way or even the best way to organize yourself to build the inspection procedures but it is a way that works well The thing that is most important is that all of the Setup Managers who will
20. ed in the VOCAL screen when a particular LIMIT Sample is displayed then you can edit the appropriate line of this file The format of this Inspection Procedure description text file is Line 1 Step Number Line 2 Label Text Line 3 Xposition of 1image Line 4 Y position of 1 image Line 5 Filename of 1 image Line 6 Xposition of 2 image Line 7 Y position of 2 image Line 8 Filename of 2 image Line 9 EES ESSE S SISSIES SISSIES EE These 9 lines repeat over and over again in the file with a set of 9 lines for each step of the Inspection Procedure If there is not a second image then the name NULL will be used for the filename of the 2 image To change the label displayed in the VOCAL window for a particular step in the inspection procedure just change the appropriate line in the file The same is true for the reference image positions NOTE The coordinates of the XY position of the images are the upper left corner of the image in pixels on the screen with the top left corner of the screen defined as X Y 0 0 VOCAL User Guide v3b doc 25 1 31 01
21. ew operators or setup managers are added or removed User Groups Manager This group includes the Setup Managers and QC Managers who are responsible for maintaining the reference images and inspection procedures in VOCAL Operator This group contains all of the Operators who will be allowed to save images during inspections They will be able to view the reference images but not make any changes to them Engineer This group can include anyone else who should be able to view the reference images and the saved inspection images They will not be able to make any changes VOCAL User Guide v3b doc 21 1 31 01 Network Directories Refs This directory contains the reference images used during the inspection procedures using the VOCAL software Manager Read Write Operator Read Engineer Read Saves This directory contains the images saved by operators during inspections Manager Read Write Operator Read Write Engineer Read Library This directory is where the Setup Managers can collect a library of part images which can be used when setting up particular VOCAL inspection procedures for the operators to use Manager Read Write Operator Read Engineer Read Setting Up an Inspection Procedure What is an Inspection Procedure in VOCAL Briefly it is a sequence of reference images that have been configured by the Setup Managers to aide the Operators in determining whether a feature of the part being inspecte
22. ge file a name BE SURE THAT THE FILE IS SAVED AS A JPEG IMAGE To save as a jpeg image select JPEG from the drop down menu located next to the Save as type box at the bottom of the opened window If JPEG is not the default save type then you may change the defaults for VisionGauge VOCAL on this workstation by setting up everything the way you want including image annotation preferences and then selecting File Setup Save and saving the setups with the name STARTUP This is a special file which if it exists in the VisionGauge directory is read by VisionGauge at startup to set defaults If the file does not exist then a factory default setup configuration is used Gather and save all of the required images before setting up the part and features for VOCAL Save all files with a descriptive name so that you can easily determine which files are which when scrolling through a list Setting up New Parts and Features From the images previously saved 1 2 Open VisionGauge Click on the VOCAL button on the right hand side of the screen Click on the File menu option in the main VisionGauge window top left hand side of screen Select Reference Image Open Browse and select the image file that you would like to use as the reference image and open it VOCAL User Guide v3b doc 12 1 31 01 The images are saved in the Go No Go Images folder located on the Desktop T
23. he network then you may be able to refer to it by name otherwise use its IP address such as http 192 168 10 5 config where the actual IP address assigned should be substituted for the dummy IP address 192 168 10 5 use throughout this appendix The following few paragraphs assume that the Groups Users and Shares are not already set up If you are not sure then before creating new ones scroll through the list of existing items to see what has already been defined Choose Security and then Groups to navigate to the User Groups Setup screen Now you can add 3 recommended groups These are Supervisor Operator and Engineer Do not try to add users to these groups yet Just close out of the User Groups Setup window VOCAL User Guide v3b doc 18 1 31 01 Now select Users to define the various users If your company already has usernames assigned it might be a good idea to use those here As you add each user you will need to assign a password and define to which groups they are assigned When you are finished adding users close the Users Setup screen Finally select Network Shares and define 2 Network Shares The names can be anything but they must match what you used in the VOCAL cfg file described in the Installation section of this Guide In this example we will use VOCAL_Refs and VOCAL_Save as the two Share names Click NEW and enter the Share name in both the Name and Path boxes NOTE In the Path box the name must be entered with
24. hich contains the workstation specific configuration for VOCAL All reference and saved images will be located on the network and should not appear in the VisionGauge directory The two directories used to save the reference and operator saved images are named Refs and Saves respectively They are located on the drive at the Charlston plant in a shared directory named ecmcat The full path name to the Refs directory is I ecmcat refs and the full path to the Saves directory is the same except that it ends with saves There is a third network directory which is not used directly by VisionGauge VOCAL but is reserved for use by the Setup Managers This directory is named Library and is also located on drive under the ecmcat directory It is used as a location where the Setup Managers can save a library of images which can be used for the GOOD and LIMIT Sample images for a specific inspection procedure using VOCAL There are three user groups setup for accessing these directories and each directory has a different set of access priviledges depending upon the group into which your login has been assigned The following table of User Groups and Directory Access Rights should be given to the Network Administrator Aimee Beck as of 1 23 01 to insure that the access rights are set up correctly A list of user logins which should be assigned to each User Group should also be given to the Network Administrator who will have to maintain the list as n
25. ich can be customized by the user simply by creating a text file in the VisionGauge main directory named VOCAL_Report cfg using a simple text editor such as Notepad The 4 items in the Reference Image report which can be customized are Title 1 Title 2 Company Name and Top Image Label Title Line No 1 Title Line No 2 Company Name Top Image Label The two title lines and company name are self explanatory with the title lines appearing at the top of the report and the company name appearing in the lower left of the report The Top Image Label is placed to the right of the top image in the report and in most cases would be REFERENCE or GOOD or GO depending upon what style of reference images you have set up The Reference Image report automatically adds a time and date stamp to the lower right corner of the report and this behavior cannot be changed VOCAL User Guide v3b doc 17 1 31 01 Appendix B SNAP Server Setup A network file server allows VOCAL to be used as an integrated network application providing for central storage of the eference image files that a Supervisor sets up for part inspection and central storage of the image files and description data that are saved during inspection procedures Keeping the saved test data and images on a file server allows other users on the network to review the data using a simple web browser and or Excel spreadsheet If your system includes a SNAP Server for network storage
26. ls cfg file is deleted or renamed then when VisonGauge VOCAL is next started it would again use the default values The format of the file is 7 lines of text with the first 3 lines corresponding to the 3 labels in the VOCAL window and the next 4 lines corresponding to the 4 Flag labels An example which would give the default behavior of VOCAL is Part Number Feature No Pass Fail Watch n a This is appropriate for many users but let s say you want the Flags assigned to the operator saved images to be GOOD REWORK SCRAP Other In this case the VOCAL_Labels cfg file would be created and the following entered Part Number Feature No GOOD REWORK SCRAP Other With this VOCAL_Labels cfg file each image saved by the operator using the VOCAL Save button will display a Flag dialog box with your specific 4 choices These custom Flag values will be saved into the HTML table file for quick review of the operator saved images by a QC Manager or Engineer VOCAL User Guide v3b doc 16 1 31 01 If instead of using a Part Number Feature style of reference images you have set up the reference images with a Reference Image followed by a series of Limit Sample images the you might want to change the VOCAL window labels to Procedure and Disposition VOCAL_Labels cfg file for this would be Procedure Disposition No GOOD REWORK SCRAP Other VOCAL_Report cfg The The Reference Image report has a number of items wh
27. mage To view the LIMIT Sample Images the Operator clicks the Next gt gt button To go back to the beginning of the inspection procedure the Operator selects the procedure from the pull down menu Advanced Special File Editing What are Special Files There are a number of special files which VisionGauge and VOCAL read to decide what to do Some of these are cfg configuration files and some are txt text files All of them can be edited with a simple text editor such as WordPad The basic configuration file used by VOCAL is VOCAL cfg which is located in the VisionGauge directory Details for this file are explained in the Basic Installation and Network Installation sections of the VOCAL User Guide ease refer there for the description There is also a VisionGauge cfg file which is read as the program is starting up to determine the parameters for the video capture card installed in your computer You should not have to change this file unless a new video capture card is added See the VisionGauge manual for the details of this file The other Special Files are all text files txt extension located in the various directories REFS and its sub directories When a new Inspection Procedure is created the VOCAL software adds the name of the procedure to a file called VOCAL_PartNumbers txt located in the root of the REFS directory NOTE The actual name of this file on your system may be different The filename used by VOCAL for the PartNum
28. nspections click the button labeled Live Video located in the VOCAL window bottom right hand corner of the screen To Save an Image 1 Obtain the image in the live video screen that you would like to save 2 Click anywhere within the Comments box located in the VOCAL window lower right hand corner of the screen VOCAL User Guide v3b doc 3 1 31 01 Type the text the reason that the image is being saved Click Save Mark the image as Pass Fail Watch N A and click OK To resume live video inspections click the Live Video button located within VOCAL window DONS To Sequence through Part Features 1 Make sure that the correct Part No is selected in the VOCAL window 2 Click Next gt gt Note This will temporarily freeze the live video signal to resume click on the Live Video button located in the VOCAL window To Exit VOCAL amp VisionGauge 1 Click the Close button located in the VOCAL window 2 Click the X at the top right hand side of the screen or select File Exit 3 Confirm that you want to exit by clicking Yes IT IS IMPORTANT THAT EACH USER LOGS OFF OF WINDOWS WHEN THEY HAVE COMPLETED THE INSPECTIONS To Log Off of Windows 1 Click on the Start button at the bottom left hand side of the screen 2 Select Log off 3 Confirm that you would like to log off by clicking Yes VOCAL User Guide v3b doc 4 1 31 01 B
29. o reach the desktop select the drop down menu located next to the Look in box Then Double click on the Go No Go Images folder This will open a new window containing the image file To resize the image 1 Click on the Edit menu option in located in the Reference Image window 2 Select Resize This will open a window labeled Image Resizing 3 Select the size you wish the image to be A coefficient of 0 60 is sufficient These are percentages of the existing image size therefore a resize coefficient of 0 50 is one half the size of the current image size 4 Click OK Once the image is resized align the image to the location on the screen where you would like it to permanently reside This is done by positioning the mouse pointer on the blue heading bar of the Reference Image clicking and holding the left mouse button and dragging the window to the desired location TO GET THE 2 REFERENCE IMAGE REPEAT THIS PROCESS ONCE THE IMAGE IS RESIZED AND LOCATED UNDER THE OTHER REFERENCE IMAGE PROCEED TO THE NEXT STEP In the VOCAL window 1 Click on the Supervisor menu option 2 Select Save This will bring up a new window labeled Enter Lock Out Password Enter Lock Out Password VOCAL User Guide v3b doc 13 1 31 01 4 Enter Password gradient all lower case 5 Click OK This will bring up a new window labeled Save Part No Feature No P
30. ow and each reference image window has a menu bar with editing viewing and help commands You can also use the right mouse button from within any reference image window to activate an equivalent floating popup menu Note that from within VisionGauge s main window you can also use the Edit sub menu s Copy to reference image command to create a new reference image window and copy the current image to it Also the Ctrl F hotkey has the same effect To close all of the reference images at once use VisionGauge s File Reference image Close all command VisionGauge s Reference image features are described in depth in chapter 4 of the VisionGauge User s Guide Generating New Reference Images 1 Open VisionGauge 2 Click on the Live Video button on the right hand side of the screen 3 Connect desired borescope to light source and camera 4 Position the borescope to obtain the image that you would like to save as a Reference Image 5 Click anywhere on the screen to freeze the image 6 Click on the File menu option 7 Select Image 8 Select Save as This will bring up a new window labeled Save File As VOCAL User Guide v3b doc 11 1 31 01 In the Save File As Window 1 Click on the drop down menu next to the Save in box just below the blue heading bar Select Desktop Double click on Go No Go Images Give the ima
31. ures Starting VOCAL In order for the file access on the file server and operator name in the HTML data tables to be correct be sure that you log into Windows using your assigned username and password Once properly logged onto your computer use either a short cut defined on the desktop or the START menu launch VisionGauge Click on the VOCAL button to prepare the program s image comparison and logging features VOCAL X File Supervisor Help Part No au Next gt gt Comments lt lt Previous Live Video _ Save _ Close Follow the specific test procedures provided by your Supervisor for the actual testing of the Test Procedure various features on the parts The description of the test procedure provided here only runs through the various steps which you must take in the VOCAL software to use its features to provide the reference images you will use during your testing and log any part images you wish to save Select the appropriate Part from the drop down list The information for the Part s 1t Feature will appear To move to the next feature in the sequence press the Next button To go back to the previous feature in the sequence press the Previous button To turn Live Video On at any time during the inspection process press the Live Video button If you wish to save an image along with comments and a Pass Fail Watch flag press the Save button in the VOCAL windo
32. w VOCAL User Guide v3b doc 8 1 31 01 Once you reach the Part s last feature VOCAL will loop around to the first feature in the sequence if you simply press the Next button Exiting VOCAL When you are done with your testing for the day and are ready to leave the VOCAL software simply exit the program by clicking on the X in the upper right of the screen or selecting Exit from the File menu Since the file server access rights and Operator Name saved with test data is obtained from the Windows login it is best to select Log Off from the START menu before you leave the workstation If you have been instructed to turn off the computer at the end of your testing then you may simply select Shut Down from the START menu VOCAL User Guide v3b doc 9 1 31 01 Supervisor Procedures The most important thing the Supervisor has to do is set up the Reference Images which will be used by the Operator to determine if the feature being inspected passes or fails the inspection This means that a number of images of good and bad examples of the features must be captured and saved by the Supervisor and then organized into a set of testing procedures for the operator VisionGauge VOCAL provides the basic tools needed to provide a robust factory floor optical inspection procedure There are two basic strategies which can be used for setting up the reference images the operator will use Which strategy you choose will depend upon how