1. eee eee ee ee 22 2 8 1 Decimal dot of the 3 digit display 23 3 System test Assi ss susa nu ee aes Se eC ee See a 24 3 1 Introduction VV 24 3 2 Single greasing cycle test 7 7 7 25 3 3 Multiple greasing cycle test 2 2 2 ee eee eee eee 26 3 4 Fast automatic cycle session 27 3 5 Resetting the system 27 4 28 4 1 au ulu 28 4 2 Periodic checks 28 4 3 Bleeding 28 4 4 Bleeding the system TT TT TT ee ee ee 29 4 5 Refilling the grease reservoir 30 4 5 1 Grease recommendations 30 4 5 2 Filling the 30 4 6 Finding malfunctions 31 4 6 1 General V VNVxV vhvhvn ITI ee o 31 4 6 2 Recognizing malfunctions 31 4 6 3 Malfunction finding table 32 4 6 4 R
2. 4 E or 7 Battery 8 Ignition switch CAN 9 Additional switch or normally opened or closed 10 Pressure switch 11 CAN CPU Figure 2 5 Wiring diagram OEM pump with CANbus IMPORTANT The internal wiring of an OEM CANbus pump is different from standard Activating the CANbus option in the control unit with a diagnosis device therefore will only be useful in combination with such a pump see internal wiring of pump connector pin 4 and 5 EG1703P04 Principle of operation 13 Automatic Greasing System Twin 3 2 3 2 2 3 3 2 3 4 5 2 way valve When the 5 2 way valve is at stationary not switched on by the control unit see Figure 2 6 greasing will take place through primary grease line A and the pressure in primary grease line B will decrease and the grease will be lead back to the reservoir through return line RB A Primary greas line A port A Ra P B Primary greas line B port B P From pump Ra Return line A to grease reservoir Return line B to grease reservoir Figure 2 6 5 2 vvay valve When the 5 2 way valve is switched on by the control unit the grease supply channel P will be connected to primary grease line B and primary grease line A will be connected to return line Ra in the pump Greasing takes place through primary grease line B the pressure in primary grease line A will decrease and the grease will be lead back to the reservoir through return line
3. Default this flash code is shown 4 times with 4 second intervals the number of flash codes can be altered with a parameter setting Lamp flashes during one complete cycle Single greasing cycle being executed 2 0 sec on 2 0 sec off See paragraph 3 2 Lamp flashes continuously Multiple greasing cycle being executed 0 2 sec on 0 2 sec off See paragraph 3 3 ATTENTION On request the lamp functionality can be inverted parameter setting option When activated the lamp operates the other way around Lamp switched ON where normally OFF and switched OFF where it used to be ON 2 7 Duty mode push button The duty mode push button is mounted in the cabin of vehicles that have to operate under very various circumstances e g earth moving machinery The button is combined with the signal lamp The driver can adjust the greasing intensity greasing frequency depending on the circumstances in which the vehicle or machine is used The operating mode of the greasing system can be adjusted for light medium or heavy duty The push button influences the length of the pause phase It is also possible to retrieve the fault codes on the signal lamp by using the duty mode push button see paragraph 4 6 4 Figure 2 16 Mode push button with signal lamp Proceed as follows to change the active duty mode 1 Switch ignition ON 2 Depress the push button once heavy duty twice medium duty or three light duty
4. EG1703P04 Preface 5 6 Automatic Greasing System Twin 3 1 1 1 2 General information Introduction With an automatic greasing system of Groeneveld all grease points of a vehicle or machine are lubricated automatically at the correct moment and with the correct amount of grease Because greasing takes places while the vehicle or machine is in operation the applied grease is spread optimally over the whole surface to be greased The greasing system requires no user intervention to operate apart from periodically replacing the grease in its reservoir Groeneveld s automatic greasing systems are designed with the utmost care and tested rigorously This guarantees an extended operational life and error free operation even under the most extreme operating conditions Proper installation using the correct type of grease and periodic checks are prerequisites for the continual hassle free operation of the system The periodic checks which take little time and effort can be performed during the normal maintenance of the vehicle or machine during oil replacement for instance Careful selection of construction materials makes the greasing system itself nearly maintenance free ATTENTION The automatic greasing system reduces the time and effort spent on manual greasing significantly However do not forget that there may be grease points that are not served by the greasing system and must still be greased by hand The Twin aut
5. parameter a Choose the heavy duty mode with the switch button and or shorten the interval period times in parameter section with the use of an Uni or PC GINA b Check the interval clock command wiring and connection green wire no 3 pump connector pin no 3 c Check with the use of an Uni or PC GINA whether the timer activation options are set correctly All grease points are over greased One or more grease points do not show grease while the other points receive sufficient grease The set greasing interval for the application is too short a Squeezed or broken secondary grease lines b Metering unit with lesser output then required c Metering unit is defect Choose the low duty mode with the switch button and or increase the interval period times in parameter section with the use of an Uni or PC GINA a Check and replace the relevant secondary line if necessary b Mount metering unit with larger grease output c Remove and clean the metering unit or mount a new one One or more grease points receive excessive amount of grease while the other points do receive the right amount of grease a Metering unit with more output then required b Metering unit with internal leak a Mount a metering unit with less grease output b Remove the metering unit and mount a new one EG1703P04 Maintenance 39 Automatic Greasing
6. tribution block When for practical considerations the switch is placed somewhere in the middle or at the beginning of the greasing system a switch with a higher switch pressure is applied Pressure switches are delivered with switch pressures of 100 125 150 or 175 bar 2 5 1 Principle of operation The principle of operation of the pressure switch is explained in three phases Phase 1 During this phase no pressure is on channel A and B There is also no pressure in chamber 1 Spring 10 pushes switch piston 2 to the left The electrical contact 3 and 4 is open ICE das oo Al sil Cae Pe r Figure 2 12 First phase Phase 2 During pumping phase A grease is pressed into channel A While the grease pressure is built up piston 6 is pushed to the right Chamber 1 is connected to channel A through the channels 7 8 and 9 As soon as the pressure in chamber 1 is more than the pressure force of the spring 10 piston 2 goes to the right The electrical contact 3 and 4 is closed by the contact plate 5 EG1703P04 Principle of operation 19 Automatic Greasing System Twin 3 Figure 2 13 Second phase During the pressure decrease phase as soon as the grease pressure in channel A is lower than the pressure force of the spring the connection of the electrical contacts is broken Phase 3 During pumping phase B grease is pressed into channel B While the grease pressure is built up cham
7. Successive no pressure line B in line B Possibly caused by a Broken damaged primary line B a Check condition of primary lines and its connectors Replace or repair when necessary b Metering unit causes internal by b Proceed with Procedure when pass an internal system leak is sus pected on page 43 c Air trapped into pump and or c1 Refill reservoir until reservoir is primary line B bled See paragraph 4 5 2 Filling the reservoir c2 Bleed the pump and primary lines Proceed with paragraph 4 3 amp 4 4 Bleeding pump amp system Ema The pressure switch was still closed 5 E O at the outset of a cycle in primary Successive pressure line A before cycle in line A Possibly caused by a Damaged PS wiring harness to a Check wiring and connectors where wires are joined Replace or repair when necessary b 5 2 way valve did not operate b Check 5 2 way valve and operate correctly manually with the use of an Uni or PC GINA Replace or repair when necessary c Pressure switch failed broken c Check and or replace pressure switch valve En The pressure switch was still closed 6 at the outset of a cycle in primary Successive pressure line B before cycle in line B 1 Possibly caused by a Interrupted PS wiring harness to a Check wiring and connectors where wires are joined Replace or repair when necessary b 5 2 way valve did not operate b Check 5 2 way valve and operate correc
8. Uni or PC GINA manual for the necessary parameter settings in order to activate one of the above mentioned possibilities 12V 20A 24V 10A a z oJ w v n o lt alu L r Electric motor of pump 8 Ignition switch 5 2 way valve 9 Command switch or normally opened or closed Minimum level switch 10 Pressure switch Test push button 11 Twin 3 display Control unit 12 Error signal output 1 max 6VV 31 ground Pump housing 13 Low level signal output 2 max 6W 31 ground Battery 14 Additional in output connection Figure 2 4 Wiring diagram with command switch and Twin 3 display 12 Principle of operation EG1703P04 L LOZ d qul d s nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 12V 20A ZAV 10 12V 3A 24V ZAC N D sx o LEE S EJ o E GN Electric motor of pump 5 2 way valve Minimum level switch Test push button Control unit Pump housing 7 8 GY PK PS 6 K 5 H
9. been interrupted ATTENTION Remember that a single cycle test only tests one of the primary grease lines To test the other primary grease line a second single cycle test has to be performed EG1703P04 System test 25 Automatic Greasing System Twin 3 3 3 Multiple greasing cycle test In order to provide additional grease to all grease points i e after cleaning the vehicle or to purge the system perform a multiple greasing cycle as follows 1 With the test push button at pump a Switch ignition ON b Push the test button at pump for more then 6 seconds The system will operate a multiple greasing cycle During the operation the green LED at Twin 3 display will flash quickly 0 2 sec on 0 2 sec off A code T2 and a running decimal dot will be indicating its pump pressure retaining and pressure decrease phase at Twin 3 display c The multiple greasing cycle can be finished by simply switching ignition OFF 2 With the switch button at Twin 3 display a Switch ignition ON b Push the switch button at least for 5 seconds Accordingly the 3 digit display starts flashing Push the switch button repeatedly until code T2 shows d Leave the code T2 flashing until the code comes on The system will operate a multiple greasing cycle See also next alinea During the operation the green LED at Twin 3 display will flash quickly 0 2 sec on 0 2 sec off A code T2 and a running decimal do
10. depends on the temperature in which the greasing system has to operate 20 C 4 F 70 C 158 F 2 lt 20 C 4 F 0 C 32 F 0 1 lt 20 C 4 F 70 C 158 F Synthetic 2 lt 20 C 4 F 0 C 32 F Synthetic 1 4 5 2 Filling the reservoir If the yellow LED and LO code at Twin 3 display lights up continuously or the signal lamp at the duty mode push button flashes for 2 minutes 0 5 sec on 0 5 sec off at the start of each cycle the minimum grease level in reservoir has been reached In this case the reservoir requires a refill as fol lows 1 When a new fillerpump or hose is used ensure no air is left in it Prime fillerpump and hose to avoid air pockets being pumped into Twin 3 pump reservoir Remove the dust cap from the filler coupling Carefully clean the filler coupling and coupling on the filler hose used Fix the filler hose on the filler coupling Fill the reservoir up to maximum level indicated on the reservoir The bottom of follower plate should line up with max level mark Remove the filler hose and fit the dust cap Fix the filler hose on filler coupling of the fillerpump in order to keep the filler hose clean Onu PWN NOTE The yellow LED and LO code at Twin 3 display or signal lamp of duty mode push button will go OFF automatically when pump reservoir has been refilled NOTE Do not fill the reservoir until the low level warning comes on at the Twin 3 display or on the signal lamp
11. eee 6 1 2 The Twin automatic greasing system 6 2 Principle 8 2 1 Introduction 2 2 8 2 2 z mem ms anid sem n Xlo nn ox oma cat ele 8 2 2 1 Greasing cycle 8 2 2 2 Greasing 9 2 3 Twin pumpunit 10 2 3 1 Control unit 2 22 ee TT TR TT eee ee ee ee eee eee 11 2 3 2 5 2 way valve 2 2 eee TRT TT TT TT TT ee ee ee eee eens 14 2 3 3 Relief valve 14 2 3 4 Test push button 14 2 3 5 Grease reservoir and its follower plate 15 2 3 6 Minimum level svvitch 15 2 4 Distribution block and metering units 16 2 4 1 Principle of operation 17 2 5 Pressure switch k 19 2 5 1 Principle of operation 19 2 6 Signal lamp TT TT TT ee ee eee eee 21 2 7 Duty mode push button 7 7 21 2 8 Twin 3 display
12. error 52 Clock battery low 53 Clock error 40 Maintenance EG1703P04 L LOZ d qul d s nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 4 6 5 Malfunction finding procedures A number of procedures to determine the correct cause of a certain malfunction are described below Procedure to check pressure switch valve and its cable 1 Disconnect the 2 pole connector from the pressure switch Measure the resistance between the two contacts using a digital multimeter When the sys tem is pressureless the resistance should be 22K ohm If required remove the switch to make sure that no pressure below the pressure switch is present Remove only the upper part the diverter valve can be left in place ATTENTION If a pressure switch without a resistor is being used in the greasing system you should measure an open load 3 7 If possible mount a pressure gauge that is suitable for a grease pressure up to 250 bar between the diverter valve and the pressure switch and bleed this connection before use Switch ignition ON Start a cycle test by pushing the test push button at the pump Check the switching moment of the pressure switch using the digital multi meter When the adjusted pressure see the side of the pressure switch is reached the contact should be closed the resistance should 0 ohm Switch ignition OFF for ending the cycle test If the pressure sw
13. for Decimal DOT is lighted constantly intervaltimer stop while it is supposed to run intervaltimer stopping the interval timer stopping the interval timer is connected correctly see wiring diagram Figure 2 4 and that of the vehicle when available Repair when necessary Fun b The green command wire no 3 is b Check with the use of an Uni or stopping the interval timer PC GINA vvhether the timer activation options are set correctly Change these parameter settings vvhen necessary The pressure switch did not close li O during a greasing cycle in primary Successive no pressure line A in line A Possibly caused by a Broken damaged primary line A a Check condition of primary lines and its connectors Replace or repair when necessary b Metering unit causes internal by b Proceed with Procedure when pass an internal system leak is sus pected on page 43 c Air trapped into pump and or c1 Refill reservoir until reservoir is primary line A c2 bled See paragraph 4 5 2 Filling the reservoir Bleed the pump and primary lines Proceed with paragraph 4 3 amp 4 4 Bleeding pump amp system 34 Maintenance EG1703P04 L LOZ nssi yo a1eq Date of issue September 2011 Automatic Greasing System Twin 3 i Tm The pressure switch did not close 4 80000 during a greasing cycle in primary
14. in primary grease line B the control unit switches the 5 2 way valve spring return off so the grease pressure in the primary grease line B decreases and the grease flows back to the reservoir EG1703P04 Principle of operation 9 Automatic Greasing System Twin 3 2 3 Twin pump unit The Twin pump unit consists of various parts These parts are shown in Figure 2 2 Follower plate 10 Electro motor 18 Guide rod follower plate Grease reservoir 11 Control unit 19 Bleeding and grease overflow Stirring gear 12 Test push button channel connected to the Cam 13 Filler coupling vvith grease filter bleeding and grease overflovv Cylinder and pistons 3x 14 Relief valve outlet no 15 5 2 vvay valve 15 Bleeding and grease overflovv out Primary grease line A outlet let Primary grease line B outlet 16 Electric connector Mechanical transmission 17 Minimum level switch OM m Figure 2 2 Twin pump unit The heart of the pump is an electrical driven piston pump This pump consists of three radially placed fixed cylinders and pistons 5 The electromotor drives the axle through the mechanical transmission 9 A cam 4 is fixed on the axle that moves the three pistons to and fro so the grease is pumped to the distribution blocks through the primary grease lines In addition to the cam the axle drives the stirring gear 3 located at the bottom of the reservoir and pushes the grease dovvnvvards A c
15. m Successive valve 2 open loads Control unit detected a too low cur rent draw to first coil of the 5 2 way valve in combination with initial system on pressure before cycle error caused by a Interrupted wiring of the coil b Defective coil a Check wiring Replace or repair when necessary b Check coil on wiring faulty check the resistance of the coil Replace or repair when necessary TET 15 iy O Successive valve 2 over current Control unit detected a too high cur rent draw to 5 2 way valve in combi nation with initial system on pressure before cycle error caused by a Short circuit in wiring of the coil b Defective coil a Check wiring Replace or repair when necessary b Check coil on wiring faulty check resistance of the coil Replace or repair when necessary con 16 C Communication error with control unit a No communication between display amp control unit b No supply voltage at the pump c Defective Twin 3 display a Check the purple communication wire no 6 between display and pump pump connector pin no 6 Repair when necessary b Check the fuse and red power wire no 1 to pump connector no 1 and the black ground wire no 2 to the pump connector no 2 Replace or repair when necessary c When no issues found as stated in solution A or B replace dis play con 17 Parameter checksum error 18 E
16. of motor Replace or repair when neces sary Check motor on wiring faulty check the resistance of the motor Replace when necessary Check the drive shaft on block ing Replace or repair when nec essary Replace the grease in the reservoir and bleed the system with a suitable grease for the obtained working conditions Increase the pump motor current limit parameter setting but only after checking whether the vehicle wiring and fuse can handle a higher setting hoo 12 IC 1 O Successive valve 1 open loads Control unit detected a too lovv current dravv to first coil of the 5 2 vvay valve in combination vvith initial system on pressure before cycle error caused by a Interrupted wiring of the coil b Defective coil Check wiring Replace or repair when necessary Check coil on wiring faulty check the resistance of the coil Replace or repair when necessary Dae 13 mE H O Successive valve 1 over current Control unit detected a too high cur rent draw to 5 2 way valve in combi nation with initial system on pressure before cycle error caused by a Short circuit in wiring of the coil b Defective coil Check wiring Replace or repair when necessary Check coil on wiring faulty check the resistance of the coil Replace or repair when necessary EG1703P04 Maintenance 37 Automatic Greasing System Twin 3 mm 14
17. switch OFF the pump when the maximum pressure is reached Switch ignition OFF or momentarily disconnect the pump connector The pressure should be steady minimum 200 bar this procedure only works for channel A The pressure may only drop when the control unit opens the valve as soon as a new cycle test is started in channel B When there is a pressure drop but there is no grease coming back it indicates a leaking metering unit Therefore check all connected grease points on an excessive grease collar indicating an internal leakage EG1703P04 Maintenance 43 Automatic Greasing System Twin 3 5 Technical data 5 1 Twin pump unit Maximum operating pressure Operating temperature Supply voltage Rating pump motor with valve nominal at 20 C Control unit absorption Advised fusing Capacity grease reservoir Nominal grease output Grease follower plate Minimum level switch Pump material Protection class The Twin automatic greasing system complies to the electromagnetic compatibility requirements of 250 bar 20 70 C 12 or 24 Vdc 72W 40mA 12 24 Vdc 10A 24 Vdc 20A 12 Vdc 2 3 4 6 or 8 litres 12 cm min standard standard hard anodised aluminium nylon reinforced IP67 Automotive directive 72 245 EC as last amended by directive 2006 28 EC Earth Moving Machinery standard ISO 13766 199
18. 9 Reservoir L1 mm L2 mm 2 Litres 185 334 Figure 5 1 3 Litres 216 365 4 Litres 272 421 Dimensions Twin pump with a 2 3 or 4 litre reservoir 44 Technical data EG1703P04 L LOZ d qul d s nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 Reservoir 6 Litres 8 Litres Figure 5 2 Dimensions Twin pump with a 6 or 8 litre reservoir 5 2 Signal lamp Max allowed power consumption 3W EG1703P04 Technical data 45 Automatic Greasing System Twin 3 5 3 Twin display Regulations EMC Off road ISO 13766 2006 Road transport 2004 104 EC Industrial equipment 2004 108 EC Environment Ambient operating temperature range 25 70 C Storage temperature range 25 a70 C Casing humidity dust IP54 Electrical Supply operating voltage range 9 32 VDC Max operating current 220 mA Open drain outputs max current 250 mA Open drain max voltage 32 VDC Cable length max 5 meter Automatic Greasing System Figure 5 3 Dimensions of the Twin display 46 Technical data EG1703P04 L LOZ d qul d s nssi yo a eq GROENEVELD www groeneveld group com Groeneveld Transport Efficien
19. General Manual Automatic Greasing System Twin 3 EG1703P04 GROENEVELD Your dficiency is ovr Challenge General information Type of manual General Manual System Automatic Greasing System Twin 3 Document number EG1703P04 Date of issue September 2011 Revision 04 All rights reserved No part of this manual may be copied and or published by means of printing photocopying microfilm or by any other means without prior written permission from Groeneveld This applies also to the drawings and diagrams appended Groeneveld reserves the right to change parts at any time without prior or direct notice to the customer The contents of this manual may also be changed without prior notice This manual applies to the standard version of the product Groeneveld cannot accept liability for any damage arising from the use of specifications other than that supplied You are requested to contact Groeneveld technical service for information concerning adjustment maintenance work or repairs that is not described in this manual Whilst this manual has been prepared with the greatest possible care Groeneveld cannot accept responsibility for any errors of the concequences of such errors Date of issue September 2011 Automatic Greasing System Twin 3 Table of Contents sas r a a d 5 1 General information 6 1 1 Introd ction sses r yr ra ra Or pes oya Pe Re ee
20. LD Figure 3 1 Test push button pump Figure 3 2 Svvitch button Twin 3 display The signal lamp or the green LED at the display flashes during the cycle test s In case of a single cycle it will flash slowly 2 sec on 2 sec off and code T1 will show at Tvvin 3 display In a multiple cycle test it will flash rapidly 0 2 sec on 0 2 sec off and code T2 will show at Tvvin 3 display Only the signal lamp will light continuously for 2 minutes in the end of each failed cycle test After the pump has been disabled due to a number failed cycles in succession the display will shovv the initial cause by means of an fault code see paragraph 4 6 4 This code can also be visualized by the signal lamp see paragraph 4 6 3 Errors that occured during the test cycles are not stored in the control unit records ATTENTION Only use the cycle test if necessary Every time a cycles test is performed grease is added to the grease points This is at the expense of the grease volume and can lead to excessive greasing of the grease points 24 System test EG1703P04 L LOZ nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 3 2 Single greasing cycle test In order to check the system perform a single greasing cycle as follows 1 With the test push button at pump a b Switch ignition ON Push the test push button at pump for 2 6 seconds The s
21. O Low RTC battery real time clock bat tery NOTE 3V battery Control unit encountered corrupted parameters during power up and restored the production default set tings Real time clock battery low 2 2 V at the control unit Replace control unit Replace control unit 19 o4 Control unit encountered a corrupted real time clock causing RTC faulty the events and errors to be stored with in accurate time amp dates caused by a RTC battery empty a Replace control unit Maintenance EG1703P04 LLOZ nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 20 roo e Unknown cause Control unit encountered an unknown cause due to a Display connected to a Twin 2 control unit or a Twin 3 control unit with SW version 1063 or lower Such a control unit does not supply additional info on the cause of the error like the Twin 3 pump does since SW version 1078 b An error cause that is not listed in the table a Replace control unit for one with a SW version 1078 or higher when the additional error information is required b Replace control unit General 1 All grease points do not receive sufficient grease and no malfunction reports have been given a The set greasing interval is too long for the application b The interval clock does not run wiring c The interval clock does not run
22. Ra For an extensive description of the greasing cycle and the influence of the position of the 5 2 way valve on the greasing cycle see paragraph 2 2 Relief valve A relief valve is mounted in the grease line between the piston pump and the 5 2 way valve see Figure 2 2 14 When the grease pressure exceeds 250 bar during the pumping phase the relief valve will redirect the grease to the reservoir The maximum grease pressure will be exceeded when a malfunction of the pressure switch which is mounted in the system occurs a malfunction in the cable of the pressure switch occurs The pressure switch is intended to end the pumping phase as soon as the minimum required grease pressure is reached Test push button The grease system can be tested by starting one or more cycles by means of the test push button on the pump unit see Figure 2 2 12 This button also can be used to reset the control unit 14 Principle of operation EG1703P04 L LOZ nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 2 3 5 Grease reservoir and its follower plate The reservoir see Figure 2 2 2 is made of a transparant impact proof plastic that resists the affect of variable temperatures and other enviromental influences The volume of the reservoir depends on its height The maximum grease level is indicated on the reservoir A warning signal in the cabin indicates when the minimum
23. System Twin 3 4 6 4 Retrieving a fault code message by signal lamp The fault message that caused the system to malfunction can be retrieved by pushing the duty mode push button for at least 6 seconds 20 sec max Directly after releasing the push button the signal lamp will show the fault message by flash code does not function with switch button on display ATTENTION Fault codes can only be retrieved when the pump communication line pin wire no 6 is not connected to an Uni or PC GINA and need to be disconnected for at least 50 seconds before a code can be retrieved The signal lamp indicates the fault codes by flashing Dozens are shown by long pulses 0 5 seconds Units are shown by short pulses 0 15 seconds Examples long short short short short 14 long long short 21 Code that causes a pump to shut off 11 No pressure line A 12 No pressure line B 13 Pressure before cycle in line A 14 Pressure before cycle in line B 15 Empty grease reservoir 20 Low supply voltage or bad wiring 21 Pressure switch circuit error 22 Open load pump circuit 23 Over current pump circuit 24 Open load valve 1 25 Over current valve 1 31 Open load valve 2 32 Over current valve 2 99 An error cause not listed in the table Replace control unit Code that do not cause a pump to shut off 10 Currently no errors available 51 Parameter checksum
24. and pumps grease through one of the grease channels If this is not chan nel A break off the cycle test by switching the ignition OFF or by momentarily disconnecting the pump connector Start another cycle test with the test push button at the pump The pump starts automatically in the other channel A While the pressure in channel A builds up some returning grease can come from the just disconnected grease line However when grease keeps flowing from this line there is an open connection between both primary grease channels most likely caused by a missing or damaged O ring under one or more metering unit s When a leak is established in the system it has to be determined in which distribution block the leak is present 4 Disconnect the primary grease line from block channel B directly after the first distribution block after the pump 5 Restart the pump in channel A When the grease leaks from outlet B of this first distribution block the leak must be found in this block When the grease leaks from the disconnected primary grease line the leak must be sought farther down the system Therefore repeat this procedure every time using the next distribution block until the leak is found NOTE To determine which distribution block channel is connected to pump outlet A you need to follow the primary grease line to the pump When there is only little leak it may be impossible to establish the leak with the operating pump Therefore
25. aximum level Because of this the air can escape directly under the grease follower plate through the bleeding channel in the grease follower plate guide The bleeding channel is opened when refilling of the grease is done above the maximum level NOTE When refilling is just above the maximum level some grease can come from the bleeding opening of the pump at the left side because some grease can enter the bleeding channel in addition to alr 4 6 Finding malfunctions 4 6 1 General The Twin greasing system is equipped as standard with an electronic control unit with a database All relevant data concerning the functioning of the greasing system are stored in that database This data can be read with the use of an Uni or PC GINA 4 6 2 Recognizing malfunctions Malfunctions are recognizable or discovered as follows signal lamp or all 3 05 including 3 digit display no longer lights up when ignition is switched ON signal lamp or Twin 3 display shows a malfunction e Retrieving a fault code on the signal lamp by means of the duty mode push button or fault codes are shown at Twin 3 display see paragraph 4 6 3 e Reading the malfunction reports saved in the database of the control unit The grease level in the pump no longer decreases When visually checking the bearings it appears that no fresh grease collar is present EG1703P04 Maintenance 31 Automatic Greasing System Twin 3 4 6 3 Malf
26. ber 11 fills with grease through channel 12 The grease pressure pushes piston 6 to the left Because of that the channel 8 is opened causing the grease to flow to chamber 1 through channel 7 and 9 As soon as the pressure in chamber 1 is higher than the pressure force of the spring 10 the piston 2 goes to the right The electrical contact 3 and 4 is closed by the contact plate 5 Figure 2 14 Third phase During the pressure decrease phase as soon as the grease pressure in channel B is lower than the pressure force of the spring spring 10 pushes piston 2 back to the left and the connection of the electrical contacts is broken 20 Principle of operation EG1703P04 L LOZ nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 2 6 Signal lamp The signal lamp is mounted in the field of vision of the driver and out of direct sunlight because of the visibility of the signals Possible this lamp can be combined with the operating push button The lamp shows the status of the greasing system and malfunction reports by means of flashing codes In the table below an overview of normal signals is given Malfunction signals are in the fault finding table see page 32 Figure 2 15 Signal lamp Lamp flashes 0 5 sec on 0 5 sec off as Code Selected duty mode soon as the ignition has been switched 4x once Heavy ON 4x twice Medium 4x three times Light
27. cy B V Stephensonweg 12 4207 HB Gorinchem P O Box 777 4200 AT Gorinchem The Netherlands Ph 31 183 641 400 F 31 183 624 474 http www groeneveld group com
28. e in primary line A or B while control unit noticed a deviant resistance over the pressure switch circuit caused by a Faulty wiring or connectors b Defective pressure switch a Check wiring connectors Replace or repair when necessary proceed with paragraph 4 6 5 Malfunction finding procedures b Replace pressure switch mim 10 fifa Successive pump open Control unit detected a too low cur rent draw to pump motor in combi nation with initial no pressure line loads A or B error caused by a Interrupted wiring a Check wiring Replace or repair when necessary b Defective motor b Check motor on wiring faulty check the resistance of the motor Replace when necessary c Defective control unit c Check control unit Replace or repair when necessary Maintenance EG1703P04 L LOZ nssi yo a1eq Date of issue September 2011 Automatic Greasing System Twin 3 a 11 Successive pump over current Control unit detected a too high cur rent draw to pump motor and aborted the attempted cycle caused by a Short circuit in wiring of motor b Short circuit in motor c Drive shaft blocked d Extreme low working temperature in combination with a grease not suitable for these conditions e The pump motor current limit setting not suitable for the extreme low working temperature Check the wiring
29. es ATTENTION Please be aware that when executed at low temperatures the output of the metering units in the end of the system might get reduced to 0 due to these missing program phases A fast automatic cycle session can only be initiated with the use of an Uni or PC GINA Please refer to the Twin 3 Uni or PC GINA manual During the session the display alternates every 5 seconds between T3 and the number of remaining cycles Once triggered this session cannot be ended by switching OFF ignition like with a Multiple test The moment ignition is switched ON again the pump resumes the session until al pre defined cycles are finished The fast automatic cycle program can be ceased by the following actions 1 With the test push button at the pump a Activating a single cycle test b Activating a multiple cycle test 2 With the use of an Uni or PC GINA a Change the preset amount of fast automatic cycles to 0 in parameters b Select either Auto F1 Single test F3 or Multiple test F4 When during the session a number of cycles fail in succession the session ends and pump disables The Twin 3 display will show the red LED and the cause by error code see Malfunction reports of Twin 3 display on page 34 All data during such a session will be stored as fast automatic cycles and successful finished cycles Resetting the system When the system has failed to operate and diagnostics has lead to a successful re
30. eservoir is filled WARNING Check that the system is pressureless before opening the system N Remove the end plugs from the distribution blocks that are at the end of each branch in the system Switch ignition ON Push the test push button at the pump for at least 6 seconds multiple cycle test Because the end plugs are removed no grease pressure is built up When the maximum pumping time has past the system switches automatically to the other primary line This is repeated until the ignition is switched OFF Switch ignition OFF as soon as pure grease without air pockets comes from the primary lines Re mount the end plugs into the distribution blocks Repeat step 4 5 and 6 until all branches of the system are bled Perform a single cycle test twice to check that the system functions correctly EG1703P04 Maintenance 29 Automatic Greasing System Twin 3 4 5 Refilling the grease reservoir 4 5 1 Grease recommendations Grease should not contain graphite or PTFE The use of correct grease in the Twin 3 system is of utmost importance The use of grease with a maximum of 5 molybdenum disulphide 52 is permitted Groeneveld recommends the use of its GreenLube grease Consult your local Groeneveld dealer prior to change of grease specifications or any other inqui ries you may have The Twin greasing system is developed for use with grease up to NLGI class 2 Which NLGI class has to be used mainly
31. essure depends on various factors as temperature grease consistency thickness and the dimensions of the greasing system During the pumping phase the metering units press a certain amount of grease the dosage through the secondary grease lines to the grease points 8 Principle of operation EG1703P04 L LOZ d qul d s nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 2 2 2 Pressure retaining phase The pressure retaining phase follows the pumping phase a period in which the pressure in the primary grease line A is maintained at a certain pressure During the pressure retaining phase the metering units can deliver the grease dosage which for various reasons was not yet delivered during the pumping phase The duration of the pressure retaining phase depends on the duration of the pumping phase This dependency is expressed in the parameter vmf venting multiply factor Example When the vmf is 1 0 the pressure retaining phase is the same length as the pumping phase When the vmf is set to 10 0 the pressure retaining phase is 10 times the length of the pumping phase Pressure decrease phase The pressure decrease phase follows the pressure retaining phase In this phase the pressure in the primary grease line A is decreased through the 5 2 way valve To accomplish this the control unit switches the 5 2 way valve on so the grease pressure in the primary grease line A is decreased and
32. etrieving a fault code message by signal lamp 40 4 6 5 Malfunction finding procedures 41 5 1 44 5 1 Twin pumpunit 44 5 2 Signal lamp UIUU NYDB 5 Y 7 8 eee eee 45 5 3 Twin 46 46 EG1703P04 Table of Contents 4 Automatic Greasing System Twin 3 Table of Contents EG1703P04 L LOZ nssi yo a1eq Date of issue September 2011 Automatic Greasing System Twin 3 Preface This general manual gives a description of the Twin automatic greasing system It aims at giving insight in the system s operation and possibilities Furthermore in this manual you will find the technical data on several components of the Twin automatic greasing system In this manual the following icons are used to inform or warn the user ATTENTION Draws the user s attention to important additional information meant to avoid problems WARNING Warns the user for physical injuries or serious damage to the equipment caused by improper ac tions Use of symbols BK Black BN Brown BU Blue GN Green GY Grey OR Orange PK Pink PS Pressure Switch PU Purple RD Red WH White YE Yellow
33. he pumping phase by switching OFF ignition this pumping phase will be continued the moment ignition is switched ON again 12V 20 24V 10A Electric motor of pump Control unit 9 Pressure svvitch 5 2 way valve Pump housing 10 Greasing cycle selector switch Minimum level switch Battery 11 Signal lamp Test push button Ignition switch Figure 2 3 Wiring diagram with signal lamp EG1703P04 Principle of operation 11 Automatic Greasing System Twin 3 Vehicles or machines of which the actual operation time is much shorter than the ignition time the connected grease points could easily get over greased In order to prevent this the interval timer can be stopped for the time the vehicle or machine is not in operation while the ignition is switched ON Figure 2 4 shows how to connect the control unit in this situation Pin 1 and 2 are as in the other diagram connected to ignition and ground Pin 3 is the additional connection for starting or stopping the interval timer on demand Depending on the available electrical connection at the vehicle or machine the interval timer can be started when e power to pin 3 is switched ON e power to pin 3 is switched OFF e ground to pin 3 is switched ON e ground to pin 3 is switched OFF Please refer to the Twin 3
34. is switched OFF proir to duty mode coming on the change will be ignored and old duty mode appears again 22 Principle of operation EG1703P04 L LOZ nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 In the table below is shown an overview of display indications When ignition is switched ON the 3 digit display forms an rotating clock indicating it s communication with the pump control unit After 10 seconds the preset duty mode selection appears along with the green LED Light duty Greasing mode with long intervals Decreased greasing output Medium duty Greasing mode with medium intervals Normal greasing output Heavy duty Greasing mode with short intervals Increased greasing output Pump performs a single cycle test LED flashes slow See paragraph 3 2 T Pump performs multiple cycle test LED flashes fast See paragraph 3 3 Lit Pump performs a number of fast automatic cycles See paragraph 3 4 lm Bi When the pump is performing fast automatic cycles without pressure retaining pressure decrease and pause phase the display alternates every 5 seconds between T3 and the number of remaining cycles In this case 047 Minimum level in the reservoir has been reached Resets itself by refilling the reservoir System error Duty cycle se
35. itch functions properly the cable should be checked for internal damage 8 Connect both contacts of the connector of the pressure switch with a separate wire 9 Disconnect the pump connector 10 Measure the resistance between pin 7 and 8 of the pump connector The measured resistance should be 0 ohm 11 Remove the wire between the contacts of the connector of the pressure switch The digital multimeter should read an open load EG1703P04 Maintenance 41 Automatic Greasing System Twin 3 Procedure to check pump and 5 2 way valve 1 Disconnect both primary grease lines from the pump outlet A and B WARNING Check whether the system is pressureless before the system is opened Connect a pressure gauge to each channel of the pump Use pressure gauges that are suitable for a grease pressure of 250 bar Switch ignition ON Push the test push button at the pump for about 4 seconds to start a cycle test The pump now pumps grease from one of the channels The pressure reading of the gauge connected to this channel should raise to the maximum attainable pressure of 230 to 250 bar ATTENTION The pump is not switched OFF by the pressure switch because the greasing system is disconnected If the pump does not reach the indicated pressure it has the following causes Air lock in the grease air bubbles Disconnect the pressure gauge and let the grease flow until no more air bubbles come from the channel If necessary refill the
36. lection possible only after the error has been solved See Malfunction reports of Twin 3 display on page 34 Indication shown when a Twin 3 display has been connected to a Twin 2 pump NOTE The display is equipped with a light sensitive cell Therefore the light intensity of the LED s is automatically dimmed when the surroundings become darker Annoying reflections in screens of the cabin are reduced to a minimum 2 8 1 Decimal dot of the 3 digit display Decimal dot lights up Interval timer stop Decimal dot flashes Interval timer run Decimal dot running 7 Pump phase active incl pressure retaining and pressure decrease phase EG1703P04 Principle of operation 23 Automatic Greasing System Twin 3 3 1 System test Introduction To test the greasing system two different cycle tests can be performed with the test push button on the pump or with switch button at the Twin 3 display see Figure 3 1 and Figure 3 2 1 The single cycle test through line A or B 2 The multiple cycle test continuous cycles through line A and B A cycle test can only be performed if the greasing system is performing the pressure retaining phase the pressure decrease phase or the pause phase NOTE When the system is already performing a pumping phase the system will not respond when the test push button or switch button is pushed Automatic Greasing System SWITCH o 1 GROENEVE
37. level has been reached A follower plate see Figure 2 2 1 is located in the reservoir above the grease This piston follows the level of the grease When the grease level falls the piston also falls under the influence of a draw spring The grease follower plate locks out air and condensation so preventing e oxidation of the grease mingling of the grease with the water of condensation saponifying of the grease The grease level in the reservoir can always be determined at a glance because the grease follower plate scrapes the walls of the reservoir Also the follower plate prevents funnel forming in the grease so the grease supply can and will be used in its entirety 2 3 6 Minimum level switch A minimum level switch monitors the grease level in the reservoir see Figure 2 2 17 When the grease reaches the minimum level this switch will notify the control unit At the beginning of every following greasing cycle a signal lamp in the cabin will flash or the yellow and green LED along with indication LO at the Twin 3 display is lit continuously as a warning that the reservoir has to be refilled EG1703P04 Principle of operation 15 Automatic Greasing System Twin 3 2 4 Distribution block and metering units Various types of metering units with the Twin greasing system are available each with a different grease output Each grease point can receive the correct dose of grease per greasing cycle by a careful choice
38. nformation 7 Automatic Greasing System Twin 3 2 Principle of operation 2 1 Introduction In this chapter the principles of operation of the various parts of the Twin automatic greasing system are discussed The greasing cycle pump unit control unit metering units pressure switch signal lamp and Twin 3 display are discussed 2 2 Greasing cycle Every greasing cycle consists of four phases The greasing cycles are performed alternately by the grease lines A and B see Figure 2 1 The 5 2 way valve which is integrated in the pump housing determines which primary grease line is connected to the pump and which is connected to the grease reservoir The total greasing cycle has a predetermined time the length of the four phases depend on the circumstances The different greasing cycles and phases are discussed below pumping phase pressure pressure pause pumping phase pressure pressure pause retaining decrease pump 5 2 valve pressure path primary line A pressure path primary line B Figure 2 1 Overview of the various phases of the greasing cycle 2 2 1 Greasing cycle A Pumping phase The greasing cycle begins with a pumping phase In this phase the grease is pumped from the reservoir through primary grease line A to the distribution blocks The pumping phase ends when the pressure at the pressure switch reaches a predetermined level The time needed to reach that predetermined pr
39. of the duty mode push button switch NOTE It is possible that during or directly after the refilling some grease comes from the bleeding opening of the pump left side 30 Maintenance EG1703P04 L LOZ nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 When pumping is difficult it is possible that the filler coupling or the filter behind this filler coupling at the pump is clogged It is also possible that the filling coupling and the coupling of the filling hose are clogged Remove the clogged parts and clean them When the grease is cold pumping can also become difficult It is advised to store the grease in a heated environment in order to smoothen the filling ATTENTION Replace or clean the internal grease filter every 500 hrs vehicle operating driving hours When refilling is performed with a filling installation of a service station it is recommended to clean or replace the filter behind the filling coupling on a regular basis at least every 500 operational hours This is because the pump of the refilling installation can easily break a clogged up filter while pumping Because of this dirt and pieces of the filter could get into the system which should be avoided in all circumstances If during the refilling process air is pumped into the reservoir and accumulates under the grease follower plate it can be removed by refilling the reservoir to just above the m
40. of the type of metering unit Part number Production week year Metering unit number Pressure switch Figure 2 7 Distribution block with metering units The metering units are mounted on a distribution block per group The distribution blocks are deliverable with 2 3 4 5 6 7 8 9 12 14 18 20 21 or 22 ports exits Grease points are connected to these ports through metering units and secondary grease lines Unused ports are sealed with a blind plug A pressure switch can also be mounted into one of the ports Because of their closed construction the metering units are exceptionally well suitable for use in dirty and dusty environment The metering units and distribution blocks are made of brass or stainless steel The various metering units are distinguished from each other using numbers see Figure 2 7 3 The table below is an overview of the various metering unit numbers and their grease capacity 0 0 025 7 0 350 1 0 050 8 0 400 2 0 100 8 5 0 700 3 0 150 9 1 000 4 0 200 10 2 000 5 0 250 11 4 000 6 0 300 16 Principle of operation EG1703P04 LLOZ d qul d s nssi Jo a1eq Date of issue September 2011 Automatic Greasing System Twin 3 2 4 1 Principle of operation Two grease chambers are located in a metering unit one for each primary grease line A and B These chambers are filled with an exact amount of grease When the actual greasing takes
41. omatic greasing system Groeneveld has developed a double line automatic greasing system especially for the use of NLGI class 2 grease The Twin system ensures that all the disadvantages of the systems currently available for class 2 grease are eliminated The Twin system has all advantages of the Groeneveld single line systems This means for instance that the system is expandible trouble free with grease points that are installed afterwards extra machine equipment The advantages of the Twin system ingenuous and fast assembly modular expansion possible parts of the system can temporarily be coupled or uncoupled clear malfunction reports registration of possible malfunctions the grease dosage can easily be adjusted per greasing point to the needs of that particular greasing point the grease dosage per greasing point remains constant under all circumstances General information EG1703P04 L LOZ nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 A Groeneveld Twin automatic greasing system comprises the following parts see Figure 1 1 1 An electric grease pump plunger pump with integrated grease reservoir and a digital control unit with data storage facility Primary grease line A Primary grease line B Distribution block Metering unit Pressure switch Secundary grease line Oy Orda ON Figure 1 1 System overview EG1703P04 General i
42. ompression channel is located betvveen the pump and the grease channels to the primary lines A relief valve 14 and a 5 2 vvay valve 6 are located in the compression channel The relief valve is a protection that leads the grease back to the reservoir vvhen the grease pressure exceeds 250 bar The 5 2 vvay valve determines the primary grease line A or B through vvhich greasing takes place It has an important task in fulfilling the four phases of the greasing cycle see paragraph 2 2 10 Principle of operation EG1703P04 L LOZ nssi yo a1eq Date of issue September 2011 Automatic Greasing System Twin 3 2 3 1 Control unit The electronic control unit steers and controls the course of the greasing cycles All system and program parameters are stored in it The control unit processes malfunction reports gives possible alarm reports and automatically records a log All relevant incidents will be stored in the log All data in the control unit will always be retained even when the power or system is switched OFF To view the log an Uni or PC GINA is needed The control unit is electrically connected according to the wiring diagram shown see Figure 2 3 The positive pole of the supply voltage 15 is connected to pin 1 As soon as the ignition is switched ON the program cycle is started at the point where it was interrupted during the preceding cycle If the preceding cycle was interrupted during t
43. places through one of both chambers the grease is pressed from the chambers to the relevant grease point The principle of operation of the metering unit is explained in the four phases below ATTENTION Do not open the metering units Prevent intrusion of dirt and thus a possible cause of malfunction Phase 1 In this phase the metering unit has not yet been filled with grease Se iae i 1 2 Figure 2 8 First phase While in operation system completely filled with grease phases 3 and 4 will take place alternately Phase 2 During pumping phase A grease is pressed into channel A While the grease pressure is built up piston 3 is pushed to the right passed channel 1 The grease fills chamber 2 through channel 1 and pushes piston 4 to the right Figure 2 9 Second phase After a while the pressure drops in the primary grease line A during the pressure decrease phase of the greasing cycle This has no influence on the metering unit EG1703P04 Principle of operation 17 Automatic Greasing System Twin 3 Phase 3 During pumping phase B grease is pressed into channel B 6 While the grease pressure is built up piston 3 is pushed back leftwards passed channel 8 The grease fills chamber 7 and pushes piston 4 back to the left The complete grease volume of chamber 2 left of piston 4 is pressed through channel 1 piston 3 channel 9 and the secondary grease line 5 to the g
44. rease point Sphere 10 in the non return valve is pushed back to clear the path to the secondary grease line Figure 2 10 Third phase After a while the pressure drops in the primary grease line B during the pressure decrease phase of the greasing cycle This has no influence on the metering unit Phase 4 In this phase the same happens as in phase 2 However chamber Figure 2 10 7 is now filled with grease Piston 4 is pushed to the right while chamber 2 is filled The complete grease volume of chamber Figure 2 10 7 is pressed through channel 8 piston 3 channel 9 and the secondary grease line 5 to the grease points Sohere 10 in the non return valve is pushed back to clear the path to the secondary grease line Figure 2 11 Fourth phase 18 Principle of operation EG1703P04 L LOZ nssi yo a eq Date of issue September 2011 Automatic Greasing System Twin 3 2 5 Pressure switch The pressure switch notifies the control unit that sufficient pressure has been built up during the pumping phase and stops the pump When the required pressure is not reached the pumping phase is only ended after reaching the set maximum pumping time An alarm will follow signal lamp Preferably the pressure switch is mounted on the distribution block located the farthest from the pump This is done to be sure that the required grease pressure of 100 bar also reaches the last dis
45. reservoir with some oil to remove the air around the pumping element Temperature too low and or grease is too viscous Therefore it is not sucked in by the pumping piston Replace the grease in the reservoir and the primary grease lines by more suitable grease for the aimed temperature Pump is faulty Replace the pump End the cycle test by switching the ignition OFF or by disconnecting the pump connector for a moment Switch ignition ON Start another cycle test with the test push button at the pump The pump should start in the other channel and the pressure gauge will quickly increase to the maximum adjusted grease pressure of 230 to 250 bar The first channel should become de pressurised When the pressure in the first channel does not drop and no pressure is built up in the other channel the 5 2 way valve is faulty Replace the valve or the entire pump 8 End the cycle test by switching of the ignition or by disconnecting the pump connector for a moment 42 Maintenance EG1703P04 L LOZ nssi yo a1eq Date of issue September 2011 Automatic Greasing System Twin 3 Procedure when an internal system leak is suspected 1 Disconnect the primary grease line of outlet B of the pump WARNING Check whether the system is pressureless before the system is opened 2 Switch ignition ON 3 Push the test push button at the pump for about 4 seconds to start a cycle test The pump is started
46. solvement the system needs a reset in order to revert to its automatic operation mode Perform a reset as follows 1 With the test push button at pump a Push the test push button at pump for 1 second Twin 3 display will revert to its active duty mode and green LED comes on or signal lamp at the duty mode push button will go off 2 With the switch button at Twin 3 display b Push the switch button at least for 5 seconds Twin 3 display will revert to its active duty mode and green LED comes on EG1703P04 System test 27 Automatic Greasing System Twin 3 4 3 Maintenance General The maintenance of Groeneveld s Twin greasing systems can be combined with the normal maintenance of the vehicle or machine WARNING When cleaning the vehicle or machine with a high pressure water steam jet cleaner the pump of the greasing system should not be directly exposed to the jet This to prevent water from entering the pump through its de aerating opening During normal operation however water will never be able to enter the pump ATTENTION The automatic greasing system reduces the time and effort spent on manaul greasing significantly However do not forget that there may be grease points that are not served by the greasing system and must still be greased by hand Periodic checks 1 Check the grease level in the reservoir and its condition Do not fill the reservoir until the low level warning comes on at the Twin 3 displa
47. t will be indicating its pump pressure retaining and pressure decrease phase at Twin 3 display e The multiple greasing cycle can be finished by simply switching ignition OFF The system will start a pumping phase After pumping phase A pressure retaining phase A and pressure decrease phase A are ended pumping phase B is started immediately then again A then B etc The pause phases are skipped entirely every time ATTENTION It is also possible to skip the pressure retaining phase and pressure decrease phase during the multiple cycles test by activating the enable fast multiple test option with an Uni or PC GINA see parameter menu Please be aware that when activated at low temperatures the output of the metering units in the end of the system might get reduced to 0 due to these missing phases When the ignition is switched ON again the program will always begin with the pause phase of the pumping phase that has just been interrupted 26 System test EG1703P04 L LOZ nssi yo a1eq Date of issue September 2011 Automatic Greasing System Twin 3 3 4 3 5 Fast automatic cycle session An fast automatic cycle session can be triggered when the connected bearings need additional grease fast i e after install or after system repair During such a session a pre defined number of greasing cycles are executed and accelerated by skipping pressure retaining pressure decrease and pause phas
48. the grease flows back to the reservoir The duration of the pressure decrease phase is equal to that of the pressure retaining phase and therefore proportional to the duration of the pumping phase When the greasing system needs more time to build up the required grease pressure because of low temperature or grease with a high viscosity the system will also need more time to decrease that same pressure Pause phase The pause phase is the period between the pressure decrease phase and the beginning of the next pumping phase in line B The length of the pause phase is equal to the predetermined cycle time minus the length of the other phases When the cycle time is adjusted too short to perform a complete greasing cycle the program will ignore the cycle time The pumping pressure retaining and pressure decrease phase will be performed completely However the pause phase will be omitted because the predetermined cycle time is exceeded The greasing system begins directly with the first phase of the next greasing cycle Greasing cycle B Greasing cycle B begins when the pause phase of the former cycle A is finished The control unit restarts the pump During pumping phase B and pressure retaining phase B the control unit switches the 5 2 way valve on causing the pump to be connected to primary grease line B The primary grease line A is shut off from the pump during these phases and connected to the reservoir During the pressure decrease phase
49. times for 1 second 3 lamp will indicate the new selected interval EG1703P04 Principle of operation 21 Automatic Greasing System Twin 3 2 8 Twin 3 display With the switch button 1 the desired operating test mode can be selected and also errors can be reset see Figure 2 17 The Twin 3 display is equipped with a 3 digit display 2 Herewith errors the active duty mode and test mode if applicable can be displayed The decimal dot 3 indicates whether the interval timer remains or is on standby see paragraph 2 8 1 The green LED 4 indicates that the system is activated The yellow LED 5 indicates when the minimum grease level has been reached The red LED 6 indicates a malfunctioning Automatic Greasing System Switch button 3 digit display Decimal dot SWITCH r System activated indicator LED Low grease level indicator LED Alarm indicator LED GROENEVELD Figure 2 17 Twin 3 display Proceed as follows to change the active duty mode 1 Switch ignition ON 2 Push the switch button for at least 5 seconds Accordingly the 3 digit display starts flashing 3 Push the switch button repeatedly until the desired duty mode shows 4 Leave the desired duty mode flashing for at least 6 seconds until the duty mode comes on This will confirm the desired duty mode has now changed IMPORTANT Do NOT switch OFF ignition when the desired duty mode still flashes Otherwise when ignition
50. tly manually with the use of an Uni or PC GINA Replace or repair when necessary c Pressure switch failed broken c Check and or replace pressure switch valve EG1703P04 Maintenance 35 36 Automatic Greasing System Twin 3 Empty reservoir Cycles that have not been per formed due to grease reservoir ran empty and disabled the pump caused by a Max number of cycles with an activated low level switch exceeded with pump low level stop activation b A combination of an activated low level switch and initial no pressure line A or B error indicating the pump ran out of grease a Refill the reservoir Proceed with paragraph 4 5 2 Filling the res ervoir procedure b Refill the reservoir Proceed with paragraph 4 5 2 Filling the res ervoir procedure Thereafter proceed with paragraph 4 3 Bleeding the pump procedure s xu Successive low supply voltage bad wiring Aborted cycles due control unit encountered successive power dips in attempt to initiate pump motor caused by a Faulty battery vehicle b Faulty wiring ground wire c Corroded pin contact in connec tor a Charge or replace battery b Check wiring Replace or repair when necessary c Check connections at pump and in cabin Replace or repair when necessary Kiz 9 mzi Faulty pressure svvitch circuit The pressure svvitch did not close during a greasing cycl
51. ue September 2011 Automatic Greasing System Twin 3 4 4 NOTE When after a few minutes still no grease exits the pump outlet we advise to pump some oil into the reservoir along the filler coupling 500 cc or 1 8 gallon will be sufficient This will help to push aside the air pockets around the pump piston The oil can also be pumped into the reservoir along grease outlet B but than first the pump need to be stopped by switching ignition OFF 6 Re mount the primary lines to the pump 7 Perform a single cycle test twice to check if the system functions correctly 8 When pressure build up in the system is still insufficient it is possible that also the primary lines need to be bled see paragraph 4 4 9 To make sure that the pump is still in good condition also the grease pressure could be measured with a manometer direct at one of the pump outlets During a pumping phase the pressure should reach 230 250 bar and is not allowed to fall below 200 bar during the successive pressure retaining phase NOTE Install a pressure gauge of minimum 250 bar along with 1 meter high pressure hose HPH onto the pump outlet The 1 meter HPH allows additional contents of grease to cancel out small pressure fluctuations Bleeding the system When the system malfunctions repeatedly due to an empty grease reservoir it is possible that one or both primary line s need s to be bled Proceed as follows 1 Make sure that the grease r
52. unction finding table To make it easier to find malfunctions when no Uni or PC GINA is available refer to the malfunction finding table In this table probable causes of malfunctions and their solutions are listed Because malfunction reports through the Twin display varies a little from the reports through the signal lamp a separate table is inserted Malfunction reports of signal lamp 1 Lamp does not flash when the a No supply voltage on pin 1 a Check fuse and replace if ignition has been switched ON b No ground wire connection with control unit or signal lamp pin 2 c Signal lamp broken d Wiring interruption between power supply and the control unit or between control unit and signal lamp necessary b Check and repair earth ground wire connection if necessary c Replace signal lamp if necessary d Check and repair wires if necessary 2 Lamp flashes for 2 minutes 0 5 sec on 0 5 sec off at the beginning of each cycle Minimum level in the reservoir has been reached Resets itself by refilling the reservoir 3 Lamp continuously lit after the ignition has been switched ON a The last 10 greasing cycles failed The control unit switched OFF the pump due to a number of failed cycles in succession in order to prevent possible environmental pollution in case of damaged hoses b Minimum level report in combination with no pressure in the system within the ma
53. valve on release in primary line A or page 42 B Because of this no pressure can be built up or released f Internal leak of metering unit Replace the metering unit or or pressure switch valve pressure switch valve g Surrounding temperature too Replace the grease in the low or grease too viscose reservoir and bleed the system h Wiring defect or bad contacts Check the wiring and contacts Replace if necessary i Other possible cause Consult the dealer ATTENTION inverted lamp functionality lamp is switched OFF where normally switched ON Date of issue September 2011 e direct low level indication on signal lamp lamp activated for the entire period the level switch is activated and not only during the pumping phases EG1703P04 Maintenance 33 Automatic Greasing System Twin 3 Malfunction reports of Twin 3 display O a No supply voltage at the display a Check fuses and or wire connec tion yellow wire Repair when One or all LED s necessary p and or 3 digit display b Ground wire disconnected b Check the ground wire brown wire Repair when necessary 27 does not Te c Display does not perform the self 1 c Replace display light up partially or test but a single LED or the 3 completely the diait di 2 2 igit display is broken moment ignition is switched on d Defective display d Replace display a The green command wire no 3 is a Check whether wire no 3
54. ximum pumping time a Push the test push button at the pump for 1 second to reset the report Locate the cause of the malfunction and repair it see point 4 b Refill the reservoir to reset the malfunction report Perform a system test and bleed the system if necessary 32 Maintenance EG1703P04 L LOZ nssi yo a eq Automatic Greasing System Twin 3 On request a divergent lamp functionality can be programmed like 4 Signal lamp lights The state of the pressure switch continuously for 2 minutes at did not change from open to the end of pumping phase closed Possible causes a The primary grease line leaks Replace or repair the line and Because of this no pressure vent the relevant line can be built up b Air pocket in the system Vent both primary lines and Within the maximum perform the multiple cycle pumping time insufficient test twice See paragraph pressure is built up 3 3 c Broken pressure switch See Procedure to check pressure switch valve and its cable on page 41 d O ring damaged or left out Check and mount a new O when replacing a metering ring if necessary Also see unit pressure switch or blind Procedure when an internal plug causing grease leakage system leak is suspected on from line A to B and vice page 43 versa e 5 2 way valve broken See Procedure to check preventing pressure build or pump and 5 2 way
55. y or on the signal lamp of the duty mode push button switch Check the functionality of the Twin 3 display or duty mode push button with signal lamp Check if the selected duty mode is applicable to working conditions of the vehicle Check the pump for damage and leakage Check the primary and secondary lines for damage and leakage Check the condition of the grease points served by the system Sufficient fresh grease should be present 7 Check system operation Perform a single grease cycle test 8 Clean the pump and its surroundings 9 Replace or clean the internal pump filter every 500 hrs vehicle operating driving hours The filter is located behind the external filler coupling beneath the reservoir 10 Check the stored data in the control unit with the use of an Uni or PC GINA Bleeding the pump When the system malfunctions repeatedly due to an empty grease reservoir it is possible that the pump needs to be bled Proceed as follows 1 Make sure that the grease reservoir is filled WARNING Check that the system is pressureless before opening the system Remove both primary lines from the pump Switch ignition ON Push the test push button at the pump for at least 6 seconds multiple cycle test Switch ignition OFF as soon as pure grease without air pockets comes from one of the pump outlets adi 28 Maintenance EG1703P04 L LOZ nssi yo a eq Date of iss
56. ystem will operate a single greasing cycle During the operation the green LED at Twin 3 display or signal lamp at the duty mode push button will flash slowly 2 sec on 2 sec off A code T1 and a running decimal dot will be indicating its pump pressure retaining and pressure decrease phase at Twin 3 display When the single greasing cycle is finished the pump reverts to automatic mode and shows its active duty mode at Twin 3 display or signal lamp at the duty mode push button will go off 2 With the switch button at Twin 3 display a b A Switch ignition ON Push the switch button at least for 5 seconds Accordingly the 3 digit display starts flashing Push the switch button repeatedly until code T1 shows Leave the code T1 flashing until the code comes on The system will operate a single greasing cycle See also next alinea During the operation the green LED at Twin 3 display will flash slowly 2 sec on 2 sec off A code T1 and a running decimal dot will be indicating its pump pressure retaining and pressure decrease phase at Twin 3 display When the single greasing cycle is finished the pump reverts to automatic mode and shows its active duty mode and green LED comes on The single cycle test ends after the pressure decrease phase or when the ignition is switched OFF When the ignition is switched ON again the program will always begin with the pause phase of the cycle that has just