Home
Modèle HT-F03A
Contents
1. or contact the store where you bought the thermometer THE SCREEN SHOWS TEMPERATURES OVER 42 9 C The temperature is in Fahrenheit See point 5 page 11 above how to change back to C THE SCREEN SHOWS UNUSUALLY LOW BODY TEMPERATURES To take the surface temperature press the Mode button and set the reading to Body THE SCREEN DISPLAYS THE MESSAGE HI When using the Thermometer the message HI can show on the Screen In this case the temperature is above the human measurement range above 42 9 C 109 2 F in Body Mode THE SCREEN DISPLAYS THE MESSAGE LO When using the thermometer the message LO can show on the Screen In this case the temperature analyzed is under the measuring range selected below 32 C 89 6 F in Body Mode This message displays for various reasons Please find below a list of the main issues Airon Medical Infraread Thermometer V 1 0 14 Reasons for LO message Advice Temperature reading Make sure there is no hair in hampered by hair or the way and that the forehead perspiration is dry Temperature hampered by air Make sure there is no draft draft or change in ambient where you use the temperature thermometer The measuring distance is too Take measurements at the far recommended distance 3 5cm WARRANTY Airon warrants its products free of defects for a period of two years from the date of retail purchase This warranty does
2. FUNCTIONS 1 Specially designed to take the human body temperature from a distance 2 Reliable and stable measurement thanks to the advantage of the Infrared Detection System Sound alarm when detecting fever Memorizes the last 32 measurements Backlit LCD digital display screen Temperature can be displayed in either C or F Automatic power off 30 sec to conserve energy Longevity use 40 000 reading Practical easy to use ADDITIONAL USAGE AIR101 can also be used to measure the temperature of a baby bottle or bath or room temperature by using the Surface Temp function This function is in accordance with the Directive 89 336 EEC Electromagnetic Compatibility VII USE 1 Install battery 2 For the first use or when inserting new batteries wait 15 minutes for the warm up of the apparatus 3 Push the SCAN key to turn the thermometer on Aim towards the temporal region of the forehead from a distance of 3 5 cm Press the SCAN key again and the temperature is instantly displayed 4 Before taking the temperature make sure to remove hair and perspiration from the forehead Airon Medical Infraread Thermometer V 1 0 10 SETTINGS AND MENU FUNCTIONS 1 MODE Room oR SURFACE TEMPERATURE Switch on the device by pressing the SCAN key Press the MODE key to change between Body Room or Surface temperature Make sure it is in Body mode when measuri
3. mm Lx W x H Unit weight 148g Display resolution 0 1 C Measuring range In Body mode 34 C 42 5 C In Surface Temp mode 0 C 60 C Precision From 36 C to 39 C 0 2 C Under 36 C and over 39 C 0 3 C Consumption lt 150mW Measuring distance 3 5 cm Automatic power off 30 sec Airon Medical Infraread Thermometer V 1 0 12 Precision From 34 til 35 9 0 3 Accordingto A amp TNEStehnd rd ccoraing to stanaar From 36 til 39 0 2 2003 From 39 til 42 5 0 3 AIR101 can take temperature readings below 34 C or above 42 5 C 89 6 F to 109 2 F but precision is not guaranteed outside of this range X ADVICE The lens is the most important and fragile part of the thermometer please take great care of it Do not use other batteries than mentioned batteries Do not recharge non rechargeable batteries Do not throw in fire Remove the batteries when thermometer is not used for an extended period of time Do not expose the thermometer to sunlight or water An impact will damage the product Xl ACCESSORIES SUPPLIED User manual Storage case Two AA alkaline batteries Airon Medical Infraread Thermometer V 1 0 13 TROUBLESHOOTING If you have problems while using your thermometer please refer to this guide to help resolve the problem If the problem persists please contact us on info airon no
4. not cover damages caused by misuse unauthorized repairs or shock drop Certificate of conformity In accordance with the Medical Device Directive93 42 EEC Model JXB182 REP Wellkang ltd Suite B 29 Harley Street LONDON W1G 9QR England United Kingdom Tel 44 20 30869438 32876300 Fax 44 20 76811874 Web www CEmark com www CE marking com www CE marking eu Email AuthRep CE marking eu GUANGZHOU JINXINBAO ELECTRONIC CO LTD NO 38 HUANZHEN ROAD DAGANG TOWN NANSHA GUANGZHOU CHINA Airon Medical Infraread Thermometer V 1 0 15
5. 0 5 C between and 3pm Women have a temperature that is higher on average by around 0 2 C Their temperature also varies in accordance with their ovarian cycle It rises by 0 5 C in the second half of the cycle and at the early stages of pregnancy HOW TO TAKE A TEMPERATURE Turn on the thermometer by pushing the SCAN button Aim at the forehead over the temporal region from a distance of about 3 5cm press the SCAN button and the temperature is instantly displayed A Measurements can be done on other parts of the body but the reliability of the measurement cannot be guaranteed if the temperature is measured on other body parts armpit torso etc INSTRUCTIONS Please observe the following before any temperature measurement to ensure a stable and reliable result Push back hair from the forehead Wipe away any perspiration from the forehead Avoid any draft e g open windows air conditioning Allow one minute interval between measurements Each time there is a significant change in the ambient temperature allow the thermometer to acclimatize to this ambient temperature for at least 15 minutes before using it Airon Medical Infraread Thermometer V 1 0 8 V DESCRIPTION OF THE THERMOMETER Infrared lens AIRON LCD panel MODE Body ial ON SCAN Surface Battery compartment Airon Medical Infraread Thermometer V 1 0 VI
6. AIRON amp ENGLISH USER MANUAL MEDICAL INFRARED THERMOMETER AIR101 AIRON 22 READ THIS MANUAL CAREFULLY BEFORE USE WWW AIRON NO 5 86 INTRODUCTION Ill PRECAUTIONS BEFORE IV OPERATING THE DIFFERENT METHODS TEMPERATURE MEASUREMENT NORMAL TEMPERATURES WITH MEASUREMENT METHODS ADVANTAGES OF TEMPORAL ARTERY MEASUREMENT NORMAL TEMPERATURES ACCORDING TO PRACTICAL CONSIDERATIONS WHEN TAKING A TEMPERATURE HOW TO TAKE A INSTRUCTIONS jeistea an eaaa a bra SERE autor V DESCRIPTION OF THE et n bete Da need SETTINGS AND MENU 1 MODE BODY ROOM OR SURFACE TEMPERATURE 2 SOUND SIGNAL 3 MEMORY zii eot Me irte Qut 4 CALIBRATION erede 5 TEMPERATURE UNIT F sese 6 CHANGING THE 12 IX TECHNICAL s etcetera neret e a E PE Ee 12 P ORE inicie 13 Xl ACCESSOR
7. IES TROUBLESHOOTING s catio re tee ettet Airon Medical Infraread Thermometer V 1 0 SAFETY PRECAUTIONS Follow the maintenance advice stipulated in this manual This device must only be used for the purposes described in this instruction manual This device must only be used in an ambient temperature between 10 C and 40 C The thermometer must always be kept in a clean dry area Do not expose this thermometer to extreme temperature conditions of gt 50 C or lt 20 C Do not use this device in relative humidity higher than 85 Do not touch the glass of the infrared lens Do not expose the thermometer to sunlight or to water Never drop the device Should a problem occur with your device please contact your retailer Do not attempt to repair this device yourself Get started 1 Insert the batteries 2 Push the SCAN button to turn on the thermometer 3 Point the thermometer towards the temporal area of the forehead 3 5 cm distance 4 Push the SCAN button again and see the result Airon Medical Infraread Thermometer V 1 0 3 Il INTRODUCTION The Airon Medical Infrared Thermometer AIR101 has been developed by using the latest infrared technology This technology allows temporal artery TA temperature to be taken at a distance of about 3 to 5cm away from the forehead Precise Instantaneous and without conta
8. ct the AIR101 is the most suitable thermometer for no risk temperature measurement It has been demonstrated that this method of TA temperature measurement is more precise than the tympanic thermometry and better tolerated than rectal thermometry 1 However as with other types of thermometers it is essential to use the AIR101 properly in order to obtain reliable and stable results You are advised to read this instruction manual and the safety precautions carefully before use 1 Greenes D Fleisher G Accuracy of a Non invasive Temporal Artery Thermometer for Use in Infants Arch Pediatr Adolesc Med 2001 155 376 Ill PRECAUTIONS BEFORE USE The AIR101 is pre set at the factory It is not necessary to calibrate the device when starting it up In order to obtain reliable and stable results you are advised each time there is a significant change in the ambient temperature due to a change in environment to allow the AIR101 to acclimatize to this ambient temperature for 15 minutes before using it If you don t you might experience varying results at first but they will stabilize when the thermometer is acclimatized It is important to allow 3 5 seconds interval between two measurements Airon Medical Infraread Thermometer V 1 0 4 OPERATING PRINCIPLE All objects solid liquid or gas emit energy by radiation The intensity of this energy depends on the temperature of the object AIR101 is able to measure the temperature of a per
9. ng fever 2 SOUND SIGNAL Switch on the device by pressing the SCAN key Press the Sound signal key to turn the signal on off 3 MEMORY Switch on the device by pressing the SCAN key Press the key to see the last 32 temperature readings 4 CALIBRATION Switch on the device by pressing the SCAN key Hold the MODE key and the Sound signal key simultaneously for two seconds and F 4 and 0 0 will appear in the display You can now set the thermometer to show higher temperatures by pressing the Sound signal key and lower temperatures by pressing the key Confirm the setting by pressing the MEM key twice 5 TEMPERATURE UNIT C F Switch on the device by pressing the SCAN key Hold the MODE key and the Sound signal key simultaneously for two seconds and F 4 and 0 0 will appear in the display Press the MEM key and set the temperature unit to C by pushing the MODE key and F by pushing the sound signal key Confirm the setting by pressing the MEM key Airon Medical Infraread Thermometer V 1 0 11 6 CHANGING BATTERIES When the screen displays Battery open the lid by pushing down the grey part of the handle and change batteries IX 1 TECHNICAL DATA Normal using condition Ambient temperature 10 C 40 C 50 F 104 F Relative humidity lt 85 Power DC 3V 2 pcs AA batteries Unit size 175 x 50 x 52
10. olerated than rectal thermometry The AIR101 thermometer is designed to produce an instant forehead temperature reading without any contact with the temporal artery This artery is quite close to the surface of this skin and therefore accessible It has a permanent and regular blood flow so it allows precise measurement of the temperature This artery is linked to the heart by the carotid artery which is directly linked to the aorta The efficiency speed and comfort of taking a temperature from this area make it ideal compared with other temperature measurements methods NORMAL TEMPERATURES ACCORDING TO AGE Alder C F 0 2 years 36 4 38 0 97 5 100 4 3 10 years 36 1 37 8 97 0 100 0 11 65 years 35 9 37 6 96 6 99 7 gt 65 years 35 8 37 5 96 4 99 5 PRACTICAL CONSIDERATIONS WHEN TAKING A TEMPERATURE In order to ensure that precise and accurate temperature measurements are obtained it is essential that each user has received adequate information on and training in the temperature measurement technique when using this device Temperature should be taken in a neutral context The patient must not have undertaken vigorous physical activity prior to taking his her temperature and the room temperature must be moderate Airon Medical Infraread Thermometer V 1 0 7 Be aware of physiological variations in temperature which must be taken into consideration when evaluating the results temperature increases by
11. ough the mouth To measure oral temperature the mouth must remain closed and the tongue lowered for three to four minutes which is a difficult task for young children to accomplish Axillary armpit temperature Although it may be easy to measure axillary temperature it has been proven that it does not provide an accurate measurement of the child s internal temperature To make this kind of measurement the thermometer must be wedged tightly over the axillary artery Despite the low sensitivity and relative inaccuracy of axillary temperature in detecting fever this method is recommended by The American Academy of Pediatrics as a screening test for fever in newborns Tympanic ear thermometry In order to obtain a precise temperature reading good command of the measurement technique is required The thermometer probe must be placed as close as possible to the warmest part of the external ear canal An incorrectly placed probe could lead to a false temperature reading NORMAL TEMPERATURES ACCORDING TO MEASUREMENT METHOD MEASUREMENT METHOD NORMAL TEMP RECTAL 36 6 38 ORAL 35 5 37 5 AXILLARY ARMPIT 34 7 37 3 AURICULAR EAR 35 8 C 38 C TEMPORAL FOREHEAD 35 8 C 37 8 C Airon Medical Infraread Thermometer V 1 0 6 ADVANTAGES OF TEMPORAL ARTERY MEASUREMENT has been demonstrated that Infrared arterial temperature is more precise than tympanic thermometry and better t
12. son by the energy the person emits This measurement can be taken thanks to an external temperature probe on the device that permanently analyses and registers the ambient temperature When the operator holds the thermometer near the body and activates the radiation sensor the measurement is taken instantly by detection of the infrared heat generated by the arterial blood flow THE DirFERENT METHODS OF TEMPERATURE MEASUREMENT Core temperature Core temperature is the most precise measurement and it involves measuring the temperature in the pulmonary artery by means of a catheter equipped with a thermal probe which can read the temperature in situ The same method is employed for probes measuring the oesophageal temperature However such invasive temperature measurement methods require specific equipment and expertise Rectal thermometry Rectal temperature adjusts slowly in comparison to the evolution of the body s internal temperature It has been demonstrated that rectal temperature remains raised long after the internal temperature of the patient has started to drop and vice versa Furthermore rectal perforations has been known to occur as a result using of this method and without appropriate sterilization techniques rectal thermometry can spread germs often found in feces Airon Medical Infraread Thermometer V 1 0 5 Oral thermometry Oral temperature is easily influenced by recent ingestion of food or drinks and by breathing thr
Download Pdf Manuals